G6K-2G-Y-TRDC3 [OMRON]

Power/Signal Relay, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT;
G6K-2G-Y-TRDC3
型号: G6K-2G-Y-TRDC3
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT

光电二极管 继电器
文件: 总10页 (文件大小:1804K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G6K  
Surface Mounting Relay with the World’s  
Smallest Mounting Area  
Surface Mounting Relay  
• Subminiature model as small as 5.2 (H) × 6.5 (W) × 10 (L) mm is ideal for  
high-density mounting (G6K(U)-2F(-Y)).  
• Low profile of 5.2 mm improves mounting efficiency (G6K(U)-2F(-Y)).  
• Light weight of 0.7 g contributes to higher speed mounting.  
• Surface mounting terminal models incorporate a unique terminal structure with  
high infrared irradiation efficiency which allows the terminal temperature to rise  
easily when mounting the IRS, thus ensuring excellent soldering.  
• Ensures a dielectric strength of 1,500 VAC and conforms to FCC Part 68 (i.e.,  
withstanding an impulse withstand voltage of 1,500 V for 10 × 160 μs).  
• -Y models offer an impulse withstand voltage of 2,500 V for 2 × 10 μs (conforms  
to Telcordia specifications) by optimizing the distance between coil and contacts.  
• Standard model conforms to UL/CSA standards, certified by BSI (EN60950).  
• Models available with a 2.54-mm terminal pitch.  
• Rated carry current: 2A.  
RoHS Compliant  
G
6
K
Model Number Legend  
G6K@-@@-@  
1
2 3  
4
1. Relay function  
None : Single-side stable model  
U
: Single-winding latching model  
2. Number of contact poles/Contact form  
2 : 2-pole/DPDT (2c)  
3. Terminal Shape  
F : Outside-L surface mounting terminals  
G : Inside-L surface mounting terminals  
P : PCB terminals  
4. Terminal Arrangement - Impulse withstand voltage  
None :Terminal Arrangement  
2.54 mm pitch  
Impulse withstand voltage Between coil and contacts (1.5 kV for 10 × 160 μs)  
Y
:Terminal Arrangement  
Between Coil-Contact Terminal 3.2 mm  
Between Contact Terminal 2.2 mm pitch  
Impulse withstand voltage Between coil and contacts  
(Conforms to Telcordia specifications: 2.5 kV for 2 × 10 μs, 1.5kV for 10 × 160 μs)  
Application Examples  
• Telecommunication equipment  
• Office automation machines  
• Test and measurement equipment  
• Building automation equipment  
• Security equipment  
• Industrial equipment  
• Amusement equipment  
• Home appliances  
1
G6K  
Surface Mounting Relay  
Ordering Information  
Surface Mounting Terminal Standard Models  
Packing  
Tube Packing  
Tape Packing  
Enclosure  
rating  
Relay  
Function  
Rated coil  
voltage  
Minimum  
packing unit  
Rated coil  
voltage  
Minimum  
packing unit  
Minimum ordering unit  
(tape packing)  
Contact form  
Model  
Model  
3 VDC  
3 VDC  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
G6K-2F  
G6K-2F-TR  
12 VDC  
24 VDC  
3 VDC  
12 VDC  
24 VDC  
3 VDC  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
Highly insulated  
G6K-2F-Y  
Highly insulated  
G6K-2F-Y-TR  
12 VDC  
24 VDC  
3 VDC  
12 VDC  
24 VDC  
3 VDC  
Single-side  
stable  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
G6K-2G  
G6K-2G-TR  
12 VDC  
24 VDC  
3 VDC  
12 VDC  
24 VDC  
3 VDC  
Fully sealed  
DPDT (2c)  
50 pcs/tube  
900 pcs/reel  
1,800 pcs/2 reels  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
Highly insulated  
G6K-2G-Y  
Highly insulated  
G6K-2G-Y-TR  
12 VDC  
24 VDC  
3 VDC  
12 VDC  
24 VDC  
3 VDC  
G
6
K
4.5 VDC  
5 VDC  
4.5 VDC  
Highly insulated  
G6KU-2F-Y  
Highly insulated  
G6KU-2F-Y-TR 5 VDC  
12 VDC  
24 VDC  
3 VDC  
12 VDC  
Single-  
winding  
latching  
24 VDC  
3 VDC  
4.5 VDC  
5 VDC  
4.5 VDC  
Highly insulated  
G6KU-2G-Y-TR 5 VDC  
Highly insulated  
G6KU-2G-Y  
12 VDC  
24 VDC  
12 VDC  
24 VDC  
PCB Terminal Standard Models  
Rated coil  
voltage  
Minimum  
packing unit  
Enclosure rating  
Relay Function  
Contact form  
Model  
3 VDC  
4.5 VDC  
5 VDC  
G6K-2P  
12 VDC  
24 VDC  
3 VDC  
Single-side stable  
4.5 VDC  
5 VDC  
Highly insulated  
G6K-2P-Y  
Fully sealed  
DPDT (2c)  
50 pcs/tube  
12 VDC  
24 VDC  
3 VDC  
4.5 VDC  
5 VDC  
Single-winding  
latching  
Highly insulated  
G6KU-2P-Y  
12 VDC  
24 VDC  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G6K-2F DC3  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.  
Note 2. When ordering tape packing, add -TR" to the model number.  
Be sure since -TR" is not part of the relay model number, it is not marked on the relay case.  
When ordering tape packing, minimum order unit is 2 reels (900 pcs 2 = 1,800 pcs).  
2
G6K  
Surface Mounting Relay  
Ratings  
Coil: Single-side Stable Models  
Contacts  
Must operate Must release Max. voltage  
Item  
Load  
Resistive load  
Bifurcated crossbar  
Ag (Au-Alloy contact)  
Item  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
Power  
consumption  
(mW)  
voltage (V) voltage (V)  
(V)  
Contact type  
Contact material  
Rated voltage  
% of rated voltage  
3 VDC  
4.5 VDC  
5 VDC  
33.0  
23.2  
21.1  
9.1  
91  
194  
0.3 A at 125 VAC,  
1 A at 30 VDC  
Rated load  
Approx.  
100  
237  
80% max.  
10% min.  
150%  
Rated carry current  
2 A  
12 VDC  
24 VDC  
1,315  
5,220  
Max. switching voltage 125 VAC, 60 VDC  
Max. switching current 1 A  
4.6  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance  
of ±10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.  
Coil: Single-winding Latching Models (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y)  
Must operate Must release Max. voltage  
Item  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
Power  
consumption  
(mW)  
voltage (V) voltage (V)  
(V)  
Rated voltage  
% of rated voltage  
3 VDC  
4.5 VDC  
5 VDC  
33.0  
23.2  
21.1  
9.1  
91  
194  
Approx.  
100  
237  
75% max.  
75% max.  
150%  
12 VDC  
24 VDC  
1,315  
5,220  
4.6  
G
6
K
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance  
of ±10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.  
Characteristics  
Relay Function  
Single-side stable models  
Single-winding latching models  
Item  
G6K-2F, G6K-2G, G6K-2PG6K-2F-Y, G6K-2G-Y, G6K-2P-YG6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y  
Contact resistance *1  
Operating (set) time  
100 mΩ max.  
3 ms max.  
3 ms max.  
Release (reset) time  
Minimum set/reset signal width  
Insulation resistance *2  
10 ms  
1,000 MΩ min. (at 500 VDC)  
Between coil and  
contacts  
1,500 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
Betweencontactsof  
different polarity  
1,000 VAC, 50/60 Hz for 1 min  
750 VAC, 50/60 Hz for 1 min  
Betweencontactsof  
the same polarity  
Between coil and  
contacts  
1,500 V (10 × 160 μs)  
2,500 V (2 × 10 μs), 1,500 V (10 × 160 μs)  
1,500 V (10 × 160 μs)  
Impulse  
withstand  
voltage  
Betweencontactsof  
different polarity  
Betweencontactsof  
the same polarity  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
Electrical  
10-55-10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2  
10-55-10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2  
Vibration  
resistance  
1,000 m/s2  
Shock  
resistance  
750 m/s2  
50,000,000 operations min. (at 36,000 operations/hour)  
100,000 operations min. (with a rated load at 1,800 operations/hour)  
10 μA at 10 mVDC  
Durability  
Failure rate (P level) *3  
Ambient operating temperature  
Ambient operating humidity  
Weight  
-40 to 70°C (with no icing or condensation)  
5% to 85%  
Approx. 0.7 g  
Note: The above values are initial values.  
*1. The contact resistance was measured with 10 mA at 1  
VDC with a voltage-drop method.  
*2. The insulation resistance was measured with a 500 VDC  
megohmmeter applied to the same parts as those used for  
checking the dielectric strength.  
*3. This value was measured at a switching frequency of 120  
operations/min and the criterion of contact resistance is  
50 Ω. This value may vary depending on the switching  
frequency  
and  
operating  
environment.  
Always  
double-check relay suitability under actual operating  
conditions.  
3
G6K  
Surface Mounting Relay  
Engineering Data  
Maximum Switching Capacity  
Durability  
Ambient Temperature vs.  
Maximum Coil Voltage  
10  
7
1,000  
250  
500  
300  
5
200  
3
30 VDC resistive load  
Ambient temperature: 23°C  
Switching frequency:  
100  
150  
100  
50  
30  
1,800 operations/hour  
1
0.7  
0.5  
AC resistive load  
10  
DC resistive load  
125 VAC resistive load  
Ambient temperature: 23°C  
Switching frequency:  
0.3  
5
3
50  
0
1,800 operations/hour  
1
0.1  
10  
0
0.2  
0.4  
0.6  
0.8  
1
1.2  
30  
50 70 100  
300 500 700 1,000  
Switching voltage (V)  
40  
20  
0
20  
40  
60  
80 100  
Switching current (A)  
Ambient temperature (°C)  
Note: The maximum coil voltage refers to the maximum  
value in a varying range of operating power  
voltage, not a continuous voltage.  
Ambient Temperature vs. Carry  
Current  
Ambient Temperature vs. Must  
Operate or Must Release Voltage  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Ambient Temperature vs. Must  
Set or Must Reset Voltage  
G6KU-2G (F/P)-Y  
2.4  
2.0  
100  
100  
90  
90  
Max. estimated value  
max.  
80  
70  
X
min.  
80  
G
6
K
1.6  
1.2  
0.8  
60  
50  
40  
70  
max.  
X
60  
50  
40  
30  
min.  
max.  
30  
20  
X
min.  
0.4  
0
Must operate voltage  
Must release voltage  
10  
0
-40  
-20  
0
20  
40  
60  
80 100  
60  
40 20  
0
20  
40  
60  
80 100  
60  
40 20  
0
20  
40  
60  
80 100  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Shock Malfunction  
Electrical Durability (with Must Operate Electrical Durability  
and Must Release Voltage) *1  
G6K-2G (F/P), G6K-2G (F/P)-Y  
(Contact Resistance) *1  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Y
100  
1,000  
Sample: G6K-2G  
1,000  
Sample: G6K-2G  
NO contact  
NC contact  
Energized  
Number of Relays: 10 pcs  
Number of Relays: 10 pcs  
Test conditions: 1 A resistive load  
at 30 VDC with an operation rate  
of 50%  
Switching frequency: 1,800  
operations/h  
Test conditions: 1 A resistive load at 30 VDC  
800  
500  
300  
with an operation rate of 50%  
80  
Switching frequency: 1,800 operations/h  
600  
400  
200  
De-  
energized  
X
1,000  
Z
1,000  
max.  
min.  
60  
40  
Must operate voltage  
100  
200  
400  
600  
800  
max.  
max.  
Contact resistance  
1,000  
Z'  
1,000  
X'  
50  
30  
min.  
min.  
max.  
min.  
Shock directions  
X
20  
0
X'  
Must release voltage  
Unit: m/s2  
Y
1,000  
Z
Y'  
Sample: G6K-2G  
10  
Z'  
Number of Relays: 10 pcs  
0.001 0.01  
0.1  
1
10  
100  
0.001 0.01  
0.1  
1
10  
100  
Y'  
Operating frequency (x103 operations)  
Operating frequency (x103 operations)  
Conditions: Shock is applied in ±X, ±Y, and ±Z  
directions three times each with and  
without energizing the Relays to check  
the number of contact malfunctions.  
Contact Reliability Test *1, *2  
Mutual Magnetic Interference  
Mutual Magnetic Interference  
G6K-2G (F/P), G6K-2G (F/P)-Y  
G6K-2G (F/P), G6K-2G (F/P)-Y  
G6K-2G (F/P), G6K-2G (F/P)-Y  
1,000  
Initial stage Test  
Initial stage Test  
Sample: G6K-2G  
+30  
+20  
NO contact  
+30  
+20  
Number of Relays: 10 pcs  
Test conditions: 10 μA resistive  
load at 10 m VDC with an  
operation rate of 50%  
NC contact  
500  
300  
+10  
+10  
0
Sample  
Sample  
0
10  
20  
Switching frequency: 7,200  
operations/h  
10  
20  
30  
De-energized  
De-energized  
Average value  
Average value  
30  
100  
Initial stage Test  
Initial stage Test  
+30  
+20  
+30  
+20  
max.  
max.  
min.  
min.  
50  
30  
+10  
0
+10  
0
Sample  
Sample  
10  
20  
30  
10  
20  
30  
Energized  
Average value  
Energized  
Average value  
10  
Must operate voltage  
Must release voltage  
0.001 0.01 0.1  
1
10  
100 1,000 10,000 100,000  
Must operate voltage  
Must release voltage  
Operating frequency (x103 operations)  
*1. The test was conducted at an ambient temperature of 23°C.  
*2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary  
according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.  
4
G6K  
Surface Mounting Relay  
External Magnetic Interference  
G6K-2G (F/P), G6K-2G (F/P)-Y  
(Average value)  
(Average value)  
(Average value)  
+30  
+20  
+30  
+20  
+30  
+20  
S
N
S
N
S
N
S
N
S
N
S
N
+10  
0
+10  
0
+10  
0
10  
10  
10  
20  
30  
20  
30  
20  
30  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
Sample: G6K-2G  
Sample: G6K-2G  
Sample: G6K-2G  
Number of Relays: 10 pcs  
Number of Relays: 10 pcs  
Number of Relays: 10 pcs  
1,200  
800  
400  
0
400  
800 1,200  
1,200  
800  
400  
0
400  
800 1,200  
1,200  
800  
400  
0
400  
800 1,200  
External magnetic field (A/m)  
External magnetic field (A/m)  
External magnetic field (A/m)  
High-frequency Characteristics  
(Isolation) *1, *2  
High-frequency Characteristics  
(Insertion Loss) ) *1, *2  
High-frequency Characteristics  
(Return Loss) *1, *2  
G6K-2G (F/P), G6K-2G (F/P)-Y  
(Average value (initial))  
G6K-2G (F/P), G6K-2G (F/P)-Y  
G6K-2G (F/P),G6K-2G (F/P)-Y  
(Average value (initial))  
(Average value (initial))  
0
0
0
1.4  
G
6
K
Sample: G6K-2G  
Sample: G6K-2F-Y  
Number of Relays: 5 pcs  
Number of Relays: 10 pcs  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
10  
1.35  
0.1  
0.2  
0.3  
20  
30  
40  
50  
60  
1.3  
1.25  
1.2  
Return loss  
1.15  
1.1  
0.4  
70  
80  
1.05  
1
Sample: G6K-2G  
V.SWR  
Number of Relays: 10 pcs  
0.5  
1
10  
100  
1
10  
100  
1
10  
100  
Frequency (MHz)  
Frequency (MHz)  
Frequency (MHz)  
Must Operate and Must Release  
Time Distribution *1  
G6K-2G (F/P), G6K-2G (F/P)-Y  
60  
Must Operate and Must Release  
Bounce Time Distribution *1  
G6K-2G (F/P) , G6K-2G (F/P)-Y  
Vibration Resistance  
G6K-2G (F/P), G6K-2G (F/P)-Y  
60  
10.0  
Must operate  
voltage  
Sample: G6K-2G  
Number of Relays:  
50 pcs  
Must operate bounce time  
Must release  
voltage  
Must release bounce time  
5.0  
40  
20  
40  
Must operate voltage  
0.0  
Must release voltage  
20  
5.0  
Sample: G6K-2G  
Number of Relays: 50 pcs  
10.0  
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
Initial  
After test  
Time (ms)  
Time (ms)  
*1. The tests were conducted at an ambient temperature of 23°C.  
*2. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics including endurance in the actual machine  
before use.  
5
G6K  
Surface Mounting Relay  
Dimensions (Unit: mm)  
Mounting Dimensions (TOP VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(TOP VIEW)  
Single-side Stable  
G6K-2F  
0.2  
7.62  
10  
0.2  
6.5  
5.08  
2.54  
8
7
6
5
0.2  
5.2  
1.6  
1.8  
7
0.1  
0.5  
1.19  
2.54  
7.8  
0.3  
(2.54) (2.54)  
5.08  
7.62  
1
2
3
4
0.8  
(1.19)  
Orientation mark  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2. The coplanarity of the terminals is 0.1 mm max.  
Note: Check carefully the coil  
polarity of the Relay.  
Mounting Dimensions (TOP VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(TOP VIEW)  
G6K-2G  
0.2  
0.2  
6.5  
10  
7.62  
5.08  
2.54  
8
7
6
5
0.2  
5.4  
1.8  
5.7  
1.8  
0.1  
4.9  
0.5  
0.5  
1.19  
2.54  
(2.54) (2.54)  
5.08  
7.62  
1
2
3
4
0.8  
(1.19)  
Orientation mark  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2. The coplanarity of the terminals is 0.1 mm max.  
Note: Check carefully the coil  
polarity of the Relay.  
G
6
K
PCB Mounting Holes (Bottom VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Bottom VIEW)  
G6K-2P  
2.54  
0.2  
0.2  
6.5  
10  
Eight, 0.85-dia. holes  
Orientation mark  
2.54  
5
1
2
3
4
0.5  
3.5  
5.08  
0.1  
0.4  
1.19  
2.54  
R0.2  
0.15  
(2.54) (2.54)  
5.08  
8
7
6
5
5.08  
7.62  
(0.71)  
Note: Check carefully the coil  
polarity of the Relay.  
(1.19)  
7.62  
Note: Each value has a tolerance of ±0.3 mm.  
Mounting Dimensions (TOP VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(TOP VIEW)  
G6K-2F-Y  
0.2  
0.2  
6.5  
7.6  
10  
5.4  
3.2  
8
7
6
5
0.2  
5.2  
1.6  
1.8  
7
0.1  
7.8  
0.5  
1.2  
3.2  
0.3  
(2.2) (2.2)  
5.4  
7.6  
1
2
3
4
0.8  
(1.2)  
Orientation mark  
Note: Check carefully the coil  
polarity of the Relay.  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2. The coplanarity of the terminals is 0.1 mm max.  
Mounting Dimensions (TOP VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(TOP VIEW)  
G6K-2G-Y  
0.2  
0.2  
6.5  
10  
7.6  
5.4  
3.2  
8
7
6
5
0.2  
5.4  
1.8  
5.7  
0.1  
4.9  
0.5  
1.2  
3.2  
1.8  
0.5  
(2.2) (2.2)  
5.4  
7.6  
1
2
3
4
0.8  
(1.2)  
Orientation mark  
Note: Check carefully the coil  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2. The coplanarity of the terminals is 0.1 mm max.  
polarity of the Relay.  
PCB Mounting Holes (BOTTOM VIEW) Terminal Arrangement/  
G6K-2P-Y  
Tolerance: ±0.1 mm  
Internal Connections  
0.2  
0.2  
6.5  
(BOTTOM VIEW)  
10  
Eight, 0.85-dia. holes  
7.6  
5.4  
Orientation mark  
3.2  
5
1
2
3
4
0.5  
3.5  
5.08  
0.1  
0.4  
1.2  
3.2  
R0.2  
0.15  
(2.2) (2.2)  
5.08  
8
7
6
5
5.4  
7.6  
(0.71)  
(1.2)  
Note: Check carefully the coil  
polarity of the Relay.  
Note: Each value has a tolerance of ±0.3 mm.  
6
G6K  
Surface Mounting Relay  
Mounting Dimensions (TOP VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(TOP VIEW)  
Single-winding Latching  
G6KU-2F-Y  
7.6  
0.2  
0.2  
6.5  
10  
5.4  
3.2  
8
7
6
5
0.2  
5.2  
1.6  
1.8  
7
S R  
0.1  
7.8  
0.5  
1.2  
3.2  
0.3  
(2.2) (2.2)  
5.4  
7.6  
1
2
3
4
0.8  
(1.2)  
Orientation mark  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2. The coplanarity of the terminals is 0.1 mm max.  
Note: Check carefully the coil  
polarity of the Relay.  
Mounting Dimensions (TOP VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(TOP VIEW)  
G6KU-2G-Y  
0.2  
0.2  
10  
6.5  
7.6  
5.4  
3.2  
8
7
6
5
0.2  
5.4  
1.8  
5.7  
1.8  
S R  
0.1  
4.9  
0.5  
1.2  
3.2  
0.5  
(2.2) (2.2)  
5.4  
7.6  
1
2
3
4
0.8  
(1.2)  
Orientation mark  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2. The coplanarity of the terminals is 0.1 mm max.  
Note: Check carefully the coil  
polarity of the Relay.  
G
6
K
PCB Mounting Holes (BOTTOM VIEW) Terminal Arrangement/  
G6KU-2P-Y  
Tolerance: ±0.1 mm  
Internal Connections  
(BOTTOM VIEW)  
0.2  
0.2  
6.5  
10  
Eight, 0.85-dia. holes  
7.6  
5.4  
Orientation mark  
3.2  
5
1
2
3
4
0.5  
3.5  
5.08  
S R  
0.1  
0.4  
1.2  
3.2  
R0.2  
0.15  
(2.2) (2.2)  
5.08  
8
7
6
5
5.4  
7.6  
(0.71)  
(1.2)  
Note: Check carefully the coil  
polarity of the Relay.  
Note: Each value has a tolerance of ±0.3 mm.  
7
G6K  
Surface Mounting Relay  
Tube Packing and Tape Packing  
2. Reel Dimensions  
(1) Tube Packing  
1.0  
17.5  
• Relays in tube packing are arranged so that the orientation  
mark of each Relay in on the left side. Fifty Relays are packed  
on one tube.  
0.5  
2
1.0  
21.5  
0.2  
13  
0.5  
21  
Be sure not to make mistakes in Relay orientation when  
mounting the Relay to the PCB.  
80 330  
Stopper  
(gray)  
Orientation of Relays  
Stopper  
(green)  
R1  
3. Carrier Tape Dimensions  
Tube length: 520 mm (stopper not included)  
No. of Relays per tube: 50 pcs  
G6K-2F, G6K-2F-Y, G6KU-2F-Y  
0.1  
5.6  
0.1  
4
+0.1  
1.5  
0.1  
0  
1.75  
7.5  
(2) Tape Packing (Surface Mounting Terminal Models)  
• When ordering Relays in tape packing, add the prefix “-TR” to  
the model number, otherwise the Relays in tube packing will  
be provided.  
0.1  
0.05  
2
0.4  
0.1  
0.1 10.35  
16  
Relays per Reel: 900 pcs  
Minimum packing unit: 2 reels (1,800 pcs)  
1. Direction of Relay Insertion  
0.1  
12  
8.6  
G
6
K
G6K-2G, G6K-2G-Y, G6KU-2G-Y  
Pulling direction  
0.05  
0.4  
0.1  
4
+0.1  
1.5  
0.1  
0.1  
0  
Orientation mark  
Top tape  
(cover tape)  
1.75  
7.5  
5.8  
0.1  
2
R0.3 max.  
Pulling  
0.1  
direction  
0.1  
16  
10.6  
0.1  
10.6  
Carrier tape  
Embossed  
tape  
0.1  
12  
3° max.  
6.9  
Recommended Soldering Method  
• The thickness of cream solder to be applied should be within a  
range between 150 and 200 m on OMRON’s recommended  
PCB pattern.  
IRS Method (for Surface-mounting Terminal Relays)  
(1) IRS Method (Mounting Solder: Lead)  
• In order to perform correct soldering, it is recommended that  
the correct soldering conditions be maintained as shown  
below on the left side.  
Soldering  
220 to 245  
Correct Soldering  
Incorrect Soldering  
180 to 200  
Relay  
Terminal  
Preheating  
150  
Land  
PCB  
Heel fillet  
is formed  
90 to 120  
20 to 30  
Solder  
Insufficient amount  
of solder  
Excessive amount  
of solder  
Time (s)  
(The temperature profile indicates the temperature on the circuit board.)  
Visually check that the Relay is properly soldered.  
(2) IRS Method (Mounting Solder: Lead-free)  
Uppwe surface of case  
(peak): 255°C max.  
Soldering  
250 max.  
230  
180  
Preheating  
150  
Relay terminal  
section  
120 max.  
30 max.  
Time (s)  
(The temperature profile indicates the temperature on the PCB.)  
8
G6K  
Surface Mounting Relay  
Approved Standards  
UL recognized:  
CSA certified:  
UL1950 (File No. E41515)  
C22.2 No. 950 (File No. LR31928)  
BSI (EN60950) (File No.9054)  
Contact form  
DPDT (2c)  
Isolation category  
Basic Insulation  
Voltage  
Number of  
test  
operations  
125 VAC  
Contact  
form  
Coil rating  
Contact rating  
2 A, 30 VDC at 40°C  
0.5 A, 60 VDC at 40°C  
0.3 A, 125 VAC at 40°C  
DPDT G6K-2G(F/P): 3 to 24 VDC  
6,000  
(2c)  
G6K(U)-2G(F/P)-Y: 3 to 24 VDC  
Precautions  
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
Long-term Continuously ON Contacts  
Maximum Allowable Voltage  
• Using the Relay in a circuit where the Relay will be ON  
continuously for long periods (without switching) can lead to  
unstable contacts because the heat generated by the coil itself  
will affect the insulation, causing a film to develop on the  
contact surfaces. We recommend using a latching relay  
(magnetic-holding relay) in this kind of circuit. If a single-side  
stable model must be used in this kind of circuit, we  
recommend using a fail-safe circuit design that provides  
protection against contact failure or coil burnout.  
• The maximum allowable voltage of the coil can be obtained  
from the coil temperature increase and the heat-resisting  
temperature of coil insulating sheath material. (Exceeding the  
heat-resisting temperature may result in burning or  
short-circuiting.) The maximum allowable voltage also involves  
important restrictions which include the following:  
• Must not cause thermal changes in or deterioration of the  
insulating material.  
G
6
K
• Must not cause damage to other control devices.  
• Must not cause any harmful effect on people.  
• Must not cause fire.  
Relay Handling  
• Use the Relay as soon as possible after opening the  
moistureproof package. (As a guideline, use the Relay within  
one week at 30°C or less and 60% RH or less.) If the Relay is  
left for a long time after opening the moisture-proof package,  
the appearance may suffer and seal failure may occur after the  
solder mounting process. To store the Relay after opening the  
moisture-proof package, place it into the original package and  
sealed the package with adhesive tape.  
Therefore, be sure to use the maximum allowable voltage  
beyond the value specified in the catalog.  
• As a rule, the rated voltage must be applied to the coil. A  
voltage exceeding the rated value, however, can be applied to  
the coil provided that the voltage is less than the maximum  
allowable voltage. It must be noted that continuous voltage  
application to the coil will cause a coil temperature increase  
thus affecting characteristics such as electrical life and  
resulting in the deterioration of coil insulation.  
• When washing the product after soldering the Relay to a PCB,  
use a water-based solvent or alcohol-based solvent, and keep  
the solvent temperature to less than 40°C. Do not put the  
Relay in a cold cleaning bath immediately after soldering.  
Coating  
• The Relay mounted on the PCB may be coated or washed but  
do not apply silicone coating or detergent containing silicone,  
otherwise the silicone coating or detergent may remain on the  
surface of the Relay.  
Claw Securing Force During Automatic Mounting  
• During automatic insertion of Relays, make sure to set the  
securing force of each claw to the following so that the Relays  
characteristics will be maintained.  
PCB Mounting  
• If two or more Relays are closely mounted with the long sides  
of the Relays facing each other and soldering is performed  
with infrared radiation, the solder may not be properly exposed  
to the infrared rays. Be sure to keep the proper distance  
between adjacent Relays as shown below.  
C
B
Direction A: 1.96 N max.  
Direction B: 4.90 N max.  
Direction C: 1.96 N max.  
A
G6K-2G  
Environmental Conditions During Operation, Storage,  
and Transportation  
• Protect the Relay from direct sunlight and keep the Relay  
under normal temperature, humidity, and pressure.  
2 mm min.  
Latching Relay Mounting  
G6K-2F  
• Make sure that the vibration or shock that is generated from  
other devices, such as relays in operation, on the same panel  
and imposed on the Latching Relay does not exceed the rated  
value, otherwise the Latching Relay that has been set may be  
reset or vice versa. The Latching Relay is reset before  
shipping. If excessive vibration or shock is imposed, however,  
the Latching Relay may be set accidentally. Be sure to apply a  
reset signal before use.  
2.7 mm min.  
• Two or more Relays may be closely mounted with the short  
sides of the Relays facing each other.  
9
G6K  
Surface Mounting Relay  
G
6
K
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. K106-E1-09  
0316(0207)(O)  
10  

相关型号:

G6K-2G-Y3VDC

Power/Signal Relay, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6K-2G-Y3VDC-TR

Electromechanical Relay, DPDT, 4.5VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output,
OMRON

G6K-2G-Y4.5VDC-TR

Electromechanical Relay, DPDT, 7.5VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output,
OMRON

G6K-2G-Y5VDC-TR

Electromechanical Relay, DPDT, 7.5VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output,
OMRON

G6K-2G-YDC5

Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6K-2G-YDC6

POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.018A (COIL), 6VDC (COIL), 100mW (COIL), 1A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON

G6K-2G-YDC9

POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.011A (COIL), 9VDC (COIL), 100mW (COIL), 1A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON

G6K-2G12VDC

Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6K-2G24VDC-TR

Electromechanical Relay, DPDT, 36VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output,
OMRON

G6K-2G3VDC

Power/Signal Relay, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6K-2G4.5VDC-TR

Electromechanical Relay, DPDT, 6.75VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output,
OMRON

G6K-2G5VDC-TR

Electromechanical Relay, DPDT, 7.5VDC (Coil), 1A (Contact), 30VDC (Contact), Random, AC/DC Output,
OMRON