G6K-2P-TR-DC9 [OMRON]
Power/Signal Relay;型号: | G6K-2P-TR-DC9 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay |
文件: | 总10页 (文件大小:1056K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
GLow6SigKnal Relay
• Compact fourth generation design, offers excellent board
space savings.
• Available in 2.54 and 3.2 mm coil-contact terminal spacing.
• “-Y” models meet 2.5 kV Bellcore surge requirements.
• Conforms to FCC Part 68.
• Terminal design based on Omron’s successful G6S relay.
• Available in PCB through-hole, SMT gullwing and SMT
“inside-L” terminals.
• UL recognized / CSA certified.
• Available in single coil latching.
• RoHS Compliant.
RC
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G6K-2F-DC5).
Terminal
Contact form
Model
Non-latching
2.54 mm spacing
Non-latching
3.2 mm coil-contact
terminal spacing
Single coil latching
3.2 mm coil-contact
terminal spacing
Gullwing
DPDT
G6K-2F
G6K-2F-Y
G6KU-2F-Y
Inside “L”
G6K-2G
G6K-2P
G6K-2G-Y
G6K-2P-Y
G6KU-2G-Y
G6KU-2P-Y
PCB through-hole
When ordering tape packing (surface mount versions), add “-TR” to the model number (e.g., G6K-2G-TR-DC5)
Specifications
■ Contact Data
Load
Resistive load (cosφ=1)
0.3 A at 125 VAC
1 A at 30 VDC
Ag (Au clad)
Rated load
Contact material
Max. carry current
1 A
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load (See note)
125 VAC, 60 VDC
1 A
37.5 VA, 30W
10 μA at 10 mVDC
Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
Low Signal Relay G6K
53
■ Coil Data
G6K- 2.5 mm coil-contact terminal spacing, standard, non-latching (G6K-2F, G6K-2G, G6K-2P)
G6K- 3.2 mm coil-contact terminal spacing, non-latching (G6K-2F-Y, G6K-2G-Y, G6K-2P-Y)
Rated voltage Rated current Coil resistance
(VDC) (mA) (Ω)
Pick-up voltage
Dropout voltage
% of rated value
10% min.
Maximum voltage Powerconsumption
(mW)
3
33.0
23.2
21.1
17.6
11.3
9.1
91
80% max.
150% max.
Approx. 100
@ 23°C to 70°C
4.5
5
194
237
341
795
1,315
5,220
6
9
12
24
4.6
G6KU- 3.2 mm spacing, single coil latching (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y)
Rated voltage Rated current Coil resistance
(VDC) (mA) (Ω)
Set-up voltage
Reset voltage
% of rated value
75% min.
Maximum voltage Powerconsumption
(mW)
3
33.0
23.2
21.1
17.6
11.3
9.1
91
75% max.
150% max.
Approx. 100
@ 23°C to 70°C
4.5
5
194
237
341
795
1,315
5,220
6
9
12
24
4.6
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C unless otherwise specified.
3. Pick-up voltage will vary with temperature
4. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
■ Characteristics
Contact resistance (See note 1)
Operate (set) time (See note 2)
Release (set) time (See note 2)
Insulation resistance (See note 3)
Dielectric strength
100 mΩ max.
3 ms max. (Approx. 1.4 ms - standard. Approx. 1.2 ms - latching)
3 ms max. (Approx. 1.3 ms - standard. Approx. 1.2 ms - latching)
1,000 MΩ min. (at 500 VDC)
1,500 VAC for 1 minute between coil contacts
1,000 VAC for 1 minute between contacts of different poles
750 VAC for 1 minute between contacts of the same pole
2,500 V, (2 x 10 μs) between coil and contacts.
(Conforms to Bellcore specifications)
Surge withstand voltage “-Y’ versions
Standard versions
1,500 V, (10 x 160 μs) between coil and contacts / contacts of different and same polarity.
(Conforms to FCC Part 68)
Vibration
Shock
Mechanical durability 10 to 55 Hz; 5.0 mm double amplitude
Malfunction durability 10 to 55 Hz; 3.3 mm double amplitude
1,000 m/s2 (approx. 100G)
750 m/s2 (approx. 75G)
Mechanical durability
Malfunction durability
Ambient temperature
Humidity
-40°C to 70°C with no icing or condensation
5 to 85% RH
Service life
Mechanical
Electrical
50,000,000 operations min. (at 36,000 operations per hour)
100,000 operations min. at rated load (at 1,800 operations per hour)
Approx. 0.7 g
Weight
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage-drop method.
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength.
4. Data shown are of initial value.
54
Low Signal Relay G6K
■ Characteristic data
Maximum Switching Capacity
Ambient Temperature vs.
Maximum Coil Voltage
Ambient Temperature vs.
Switching Current
AC resistive load
DC resistive load
Ambient temperature (°C)
Ambient temperature (°C)
Rated operating voltage (V)
Note: The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
Ambient Temperature vs. Must
Electrical Service Life
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Max. estimated value
Max. estimated value
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Operate voltage
Release voltage
Ambient temperature (°C)
Ambient temperature (°C)
Rated operating current (A)
Electrical Service Life
Shock Malfunction
Electrical Service Life
(Contact Resistance) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
(with Must Operate and Must
Release Voltage) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Energized
NO
Sample: G6K-2G
Sample: G6K-2G
contact
Not
energized
Number of Relays: 10
Number of Relays: 10
NC
contact
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Must operate
Contact resistance
Shock direction
Unit: m/s 2
Sample: G6K-2G
Number of Relays: 10
Must release
Conditions: Shock is applied in X, Y, and Z di
rections three times each with and with
out energizing the Relays to check the
number of contact malfunctions.
Operating frequency (x103operations)
3
Operating frequency (x10 operations)
Note: The tests were conducted at an
ambient temperature of 23°C.
Note: The tests were conducted at an
ambient temperature of 23°C.
Low Signal Relay G6K
55
Mutual Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
Mutual Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
Contact Reliability Test (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
NO
Sample: G6K-2G
Initial stage
Test
contact
NC
Number of Relays: 10
Initial stage
Test
Test conditions: 10 mA resistive load at
10 mVDC with an operation rate of 50 %
Switching frequency: 7,200 operations/h
contact
Sample
Sample
Not energized
Not energized
Average value
Test
Average value
Initial stage
Initial stage
Test
Sample
Sample
Energized
Energized
Average value
Average value
Operating frequency (x103operations)
Note 1: The test was conducted at an ambient temperature of 23°C.
2: The contact resistance data are periodically measured reference values and are not values from each monitoring operation.
Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check
operation under the actual operating conditions before use.
External Magnetic Interference
G6K-2G (F/P), G6K-2G (F/P)-Y
(Average value)
(Average value)
(Average value)
Sample: G6K-2G
Number of Relays: 10
Sample: G6K-2G
Number of Relays: 10
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
Sample: G6K-2G
Number of Relays: 10
Must operate voltage
Must release voltage
External magnetic field (A/m)
External magnetic field (A/m)
External magnetic field (A/m)
High-frequency Characteristics High-frequency Characteristics High-frequency Characteristics
(Isolation)
G6K-2G (F/P), G6K-2G (F/P)-Y
(Insertion Loss)
G6K-2G (F/P), G6K-2G (F/P)-Y
(Return Loss)
G6K-2G (F/P),G6K-2G (F/P)-Y
(Average value)
(Average value)
(Average value)
0
0
0
10
20
30
40
50
60
70
80
90
100
1.4
Sample: G6K-2G
Sample: G6K-2G
Number of Relays: 10
Number of Relays: 10
10
20
30
40
50
60
70
80
1.35
1.3
0.1
1.25
1.2
0.2
0.3
0.4
0.5
Return loss
1.15
1.1
1.05
1
Sample: G6K-2G
Number of Relays: 10
V.SWR
1
10
100
1
10
100
1
10
100
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
Note: 1. The tests were conducted at an ambient temperature of 23°C.
2. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics including
endurance in the actual machine before use.
56
Low Signal Relay G6K
Must Operate and Must Release Must Operate and Must Release
Vibration Resistance
G6K-2G (F/P), G6K-2G (F/P)-Y
Time Distribution (See note.)
Bounce Time Distribution (See note.)
G6K-2G (F/P) , G6K-2G (F/P)-Y
G6K-2G (F/P), G6K-2G (F/P)-Y
Sample: G6K-2G
Must operate
bounce time
Must release
bounce time
Must operate
Number of Relays:
50
Must release time
Must operate voltage
Must release voltage
Sample: G6K-2G
Number of Relays: 50
After test
Time (ms)
Time (ms)
Note: The tests were conducted at an ambient temperature of 23°C.
■ Approvals
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Contact form
Coil rating
3 to 24 VDC
Contact ratings
Number of test operations
6,000
DPDT
1 A at 30 VDC (Resistive)
0.5 A at 60 VDC (Resistive)
0.3 A at 125 VAC (General Use)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
Terminal Arrangement/
Internal Connections
(Top View)
G6K-2F
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Top View) Terminal Arrangement/
G6K-2G
G6K-2P
Internal Connections
(Top View)
Tolerance: 0.1 mm
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: 0.1 mm
Eight, 0.8-dia. holes
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Low Signal Relay G6K
57
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
Terminal Arrangement/
Internal Connections
(Top View)
G6K-2F-Y
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
Terminal Arrangement/
Internal Connections
(Top View)
G6K-2G-Y
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Bottom View) Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: 0.1 mm
G6K-2P-Y
Eight,
0.8-dia. holes
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
G6KU-2F-Y
G6KU-2G-Y
G6KU-2P-Y
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
Terminal Arrangement/
Internal Connections
(Top View)
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
Mounting Dimensions (Bottom View) Terminal Arrangement/
Internal Connections
(Bottom View)
Tolerance: 0.1 mm
Eight, 0.8-dia. holes
Orientation mark
Note: Each value has a tolerance of 0.3 mm.
58
Low Signal Relay G6K
■ Packaging Information
Tube packing
Standard nomenclature
50 pcs per anti-static tube
900 pcs per reel
2 reels per box
Tape packing
(SMT versions, only)
When ordering, add “TR” before the rated coil voltage (e.g., G6K-2G-TR-DC5).
Note: TR is not part of the relay model number and will not be marked on the relay.
Order in box multiples
(see details below)
Relays in tube packing are arranged so that the orientation mark of each Relay is on the left side.
Be sure to reference Relay orientation when mounting the Relay to the PCB.
Orientation of Relays
Stopper (gray)
Stopper (green)
Tube length: 520 mm (stopper not included)
No. of Relays per Tube: 50
■ Tape and Reel Dimensions (Surface Mount Models)
• Tape type: ETX7200 (EIAJ - Electronic Industrial Association of Japan)
• Reel type: RPM-16D (EIAJ, 330 mm diameter)
• Relays per reel: 900
3. Carrier Tape Dimensions
G6K-2F, G6K-2F-Y, G6KU-2F-Y
1. Direction of Relay Insertion
Orientation mark
Top tape
(cover tape)
Pulling
direction
Carrier tape
Emboss
tape
G6K-2G, G6K-2G-Y, G6KU-2G-Y
2. Reel Dimensions
Low Signal Relay G6K
59
■ Recommended Soldering Method
Temperature indicates the surface temperature of the PCBs.
IRS Method (for surface mounting terminal models)
(1) IRS Method (Mounting Solder: Lead)
(2) IRS Method (Mounting Solder: Lead-free)
Upper surface of case (peak):
255˚C max.
Soldering
250 max.
Soldering
230
220 to
245
180
180 to
200
Preheating
150
Relay
terminal
section
Preheating
150
120 max.
30 max.
Time (s)
20 to 30
90 to 120
Note: The temperature profile indicates the
temperature of the relay terminal
section.
Time (s)
• The thickness of cream solder to be applied should be within a range between 150 and 200 μm on OMRON’s recommended PCB pattern.
• In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side.
Correct Soldering
Incorrect Soldering
Relay
Insufficient
amount of
solder
Excessive
amount of
solder
Terminal
Solder
PCB
Land
Visually check that the Relay is properly soldered.
Precautions
■ Correct Use
Handling
Do not unpack the relay until mounting it.
Environmental Conditions During Operation,
Storage, and Transportation
It is best to keep the relay in its packaging in a controlled environ-
ment until it is ready for mounting.
Soldering
Solder: JIS Z3282, H63A or equivalent
If the Relay is stored for a long time in an adverse environment with
high temperature, high humidity, organic gases, or sulfide gases, sul-
fide or oxide films will form on the contact surfaces. These films may
result in unstable contact, contact problems, or functional problems.
Therefore, operate, store, or transport the product under specified
environmental conditions.
Soldering temperature: Approx. 250°C (260°C if the DWS method is
used)
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used)
Be sure to make a molten solder level adjustment so that the solder
will not overflow on the PCB.
Latching Relay Mounting
Make sure that the vibration or shock that is generated from other
devices, such as relays in operation, on the same panel and imposed
on the Latching Relay does not exceed the rated value, otherwise the
Latching Relay that has been set may be reset or vice versa. The
Latching Relay is reset before shipping. If excessive vibration or
shock is imposed, however, the Latching Relay may be set acciden-
tally. Be sure to apply a reset signal before use.
Claw Securing Force During Automatic
Mounting
During automatic insertion of Relays, make sure to set the securing
force of each claw to the following so that the Relays characteristics
will be maintained.
Maximum Allowable Voltage
The maximum allowable voltage of the coil can be obtained from the
coil temperature increase and the heat-resisting temperature of coil
insulating sheath material. (Exceeding the heat-resisting tempera-
ture may result in burning or short-circuiting.) The maximum allow-
able voltage also involves important restrictions which include the
following:
Direction A: 1.96 N
Direction B: 4.90 N
Direction C: 1.96 N
60
Low Signal Relay G6K
• Must not cause thermal changes in or deterioration of the insulating
material.
• Must not cause damage to other control devices.
• Must not cause any harmful effect on people.
• Must not cause fire.
Therefore, be sure to use the maximum allowable voltage as speci-
fied in the catalog.
As a rule, the rated voltage must be applied to the coil. A voltage
exceeding the rated value, however, can be applied to the coil pro-
vided that the voltage is less than or equal to the maximum allowable
voltage. It must be noted that continuous voltage application to the
coil will cause a coil temperature increase which may affect charac-
teristics such as electrical life and coil insulation.
Coating
The Relay mounting on the PCB may be coated or washed but do not
apply silicone coating or detergent containing silicone, otherwise the
silicone coating or detergent may remain on the surface of the Relay.
PCB Mounting
If two or more Relays are closely mounted with the long sides of the
Relays facing each other and soldering is performed with infrared
radiation, the solder may not be properly exposed to the infrared
rays. Be sure to keep the proper distance between adjacent Relays
as shown below to insure formation of good solder joints.
G6K-2G
2 mm min.
G6K-2F
2.7 mm min.
Two or more Relays may be mounted as closely as desired with the
short sides of the Relays facing each other.
Low Signal Relay G6K
61
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11
Specifications subject to change without notice
Printed in USA
Cat. No. X301-E-1b
Low Signal Relay G6K
相关型号:
G6K-2P-TR24VDC
Power/Signal Relay, DPDT, Momentary, 24VDC (Coil), 1A (Contact), 30VDC (Contact), AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-TR5VDC
Power/Signal Relay, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-Y
Surface Mounting Relay with the World’s Smallest Mounting Area and a Height of Only 5.2 mm
OMRON
G6K-2P-Y-4.5VDC
Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-Y-5VDC
Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-Y-DC24
Power/Signal Relay, DPDT, Momentary, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-Y-DC3
Power/Signal Relay, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-Y-DC4.5
Power/Signal Relay, DPDT, Momentary, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-Y-DC5
Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G6K-2P-Y-DC9
Power/Signal Relay, DPDT, Momentary, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明