RF Relay, DPDT, Latched, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT;![G6KU-2F-RF-S-TR09DC9](http://pdffile.icpdf.com/pdf2/p00221/img/icpdf/G6KU-2F-RF-T_1288861_icpdf.jpg)
型号: | G6KU-2F-RF-S-TR09DC9 |
厂家: | ![]() |
描述: | RF Relay, DPDT, Latched, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT 光电二极管 |
文件: | 总8页 (文件大小:414K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
High Frequency Relay
G6K-RF
Compact High Frequency Relays with
2 Form C (DPDT) Contacts
• New Space-saving version with smaller ground terminal
footprint is available. (“-S” versions)
• Handles 1 A, 30 VDC discrete load and 1 W at 1GHz.
• Single-coil latching models available.
• Ambient temperature range: -40° to 70°C
• Low coil power consumption: 100 mW.
• Ideal for instrumentation and high-speed LAN network equipment.
• RoHS Compliant
Ordering Information
PCB Footprint
Max.Load
Coil Voltage
3 VDC
Non-Latching part number
G6K-2F-RF DC3
Single-coil latching part number
G6KU-2F-RF DC3
Standard ground 1 A at 30 VDC,
terminal
0.3 A at 125 VDC
4.5 VDC
5 VDC
G6K-2F-RF DC4.5
G6K-2F-RF DC5
G6KU-2F-RF DC4.5
G6KU-2F-RF DC5
6 VDC
G6K-2F-RF DC6
G6KU-2F-RF DC6
9 VDC
G6K-2F-RF DC9
G6KU-2F-RF DC9
12 VDC
24 VDC
3 VDC
G6K-2F-RF DC12
G6K-2F-RF DC24
G6K-2F-RF-S DC3
G6K-2F-RF-S DC4.5
G6K-2F-RF-S DC5
G6K-2F-RF-S DC6
G6K-2F-RF-S DC9
G6K-2F-RF-S DC12
G6K-2F-RF-S DC24
G6KU-2F-RF DC12
G6KU-2F-RF DC24
G6KU-2F-RF-S DC3
G6KU-2F-RF-S DC4.5
G6KU-2F-RF-S DC5
G6KU-2F-RF-S DC6
G6KU-2F-RF-S DC9
G6KU-2F-RF-S DC12
G6KU-2F-RF-S DC24
Space-saving
ground terminal
4.5 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
Note: The above listed models are packaged in trays of 300. They are also available in Tape and Reel packaging.
1. Place “-TR03” before the coil voltage to obtain Tape and Reel packaging, in quantities of 300 pieces per reel.
2. Place “-TR09” before the coil voltage to obtain Tape and Reel packaging, in quantities of 900 pieces per reel.
Examples: G6K-2F-RF-S-TR09 DC5
G6KU-2F-RF-TR03 DC12
3. “-TR03” and “-TR09” is only used to identify the tape quantity when ordering and is not marked on the product, itself.
Specifications
■ Contact Ratings
Load
Resistive load
Contact Material
Rated load
Au alloy on Ag base
0.3 A at 125 VAC; 1 A at 30 VDC
1 W at 1 GHz (See note.)
Rated carry current
1 A
Max. switching voltage
125 VAC, 60 VDC
1 A
Max. switching current
Max. switching capacity
37.5 VA (AC); 30 W (DC)
Note: This value is for a load with V.S.W.R. ≤ 1.2
High Frequency Relay G6K-RF
321
■ Coil Ratings
Rated voltage
Rated current
Coil resistance Must operate
voltage
Must release
voltage
Maximum voltage
Rated power
consumption
3 VDC
4.5 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
33.0 mA
23.2 mA
21.1 mA
17.6 mA
11.3 mA
9.1 mA
91 Ω
80% max. of rated 10% min. of rated 150% of rated voltage Approx. 100 mW
voltage voltage
194 Ω
237 Ω
341 Ω
795 Ω
1,315 Ω
5,220 Ω
(75% max. of rated (75% max. of rated
set voltage for
latching models)
reset voltage for
latching models)
4.6 mA
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
■ High Frequency Characteristics at 1 GHz
Isolation
20 dB min. between contacts of the same pole
30 dB min. between contacts of different poles
0.2 dB max.
Insertion loss
V.S.W.R.
1.2 max.
Maximum transmission capacity
Maximum switching capacity
3 W (See note 3)
1 W (See note 3)
Note: 1. The impedance of the measurement system is 50 Ω.
2. The above values are initial
3. These values are for a load with V.S.W.R. ≤ 1.2
■ Characteristics
Item
Single-side stable models
G6K-2F-RF(-S)
Single-winding latching models
G6KU-2F-RF(-S)
Contact resistance (See note 2.)
Operating (set) time (See note 3.)
Release (reset) time (See note 3.)
Minimum set/reset pulse time
Insulation resistance (See note 4.)
100 mΩ max.
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.2 ms)
3 ms max. (approx. 1.2 ms)
10 ms
3 ms max. (approx. 1.3 ms)
---
1,000 MΩ min. (at 500 VDC)
750 VAC, 50/60 Hz for 1 min
Dielectric strength
Between coil and
contacts
Between contacts of
different poles
750 VAC, 50/60 Hz for 1 min
Between contacts of the 750 VAC, 50/60 Hz for 1 min
same pole
Between ground and
coil/contacts
500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 5-mm double amplitude and 55 to 500 to 55 Hz, 300 m/s2
10 to 55 Hz, 3.3-mm double amplitude and 55 to 500 to 55 Hz, 200 m/s2
1,000 m/s2
Vibration resistance
Shock resistance
Endurance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
750 m/s2
50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
100,000 operations min. (at a switching frequency of 1,800 operations/hour)
Operating: −40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Ambient temperature
Ambient humidity
Weight
Approx. 0.95 g
Note: 1. The above values are initial values.
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
3. Values in parentheses are typical values.
4. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
322
High Frequency Relay G6K-RF
Engineering Data
G6K-2F-RF
Agile HP 8753D
Vector Network
Analyzer
50 Ω
terminaltion
High-Frequency Characteristics
(Isolation)
High-frequency Characteristics
(Insertion Loss)
High-frequency Characteristics
(Return Loss, V.S.W.R.)
G6K-2F-RF
G6K-2F-RF
G6K-2F-RF
Average value (initial)
Average value (initial)
Average value (initial)
0
0
1.8
0
Test subject: G6K-2F-RF
Number of Units: 10
Test subject: G6K-2F-RF
Number of Units: 10
Test subject: G6K-2F-RF
Number of Units: 5
10
1.7
10
0.1
20
30
40
50
60
70
1.6
1.5
1.4
1.3
1.2
20
30
0.2
0.3
40
50
60
Return loss
V.S.W.R.
0.4
0.5
80
90
1.1
1.0
70
80
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
G6K-2F-RF-S
G6K-2F-RF-S
G6K-2F-RF-S
Average value (initial)
Average value (initial)
Average value (initial)
0
0
1.8
0
Test subject: G6K-2F-RF-S
Number of Units: 5
Test subject: G6K-2F-RF-S
Number of Units: 10
Test subject: G6K-2F-RF-S
Number of Units: 10
10
20
30
40
50
60
70
1.7
10
20
30
40
50
60
0.1
0.2
0.3
1.6
1.5
1.4
1.3
1.2
Return loss
V.S.W.R.
0.4
0.5
1.1
1.0
70
80
90
80
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
Note: 1. Refer to the G6K specification for basic specifications and characteristics not shown above
2. Ambient temperature condition: 23°C
3. The high-frequency characteristics depend on the mounting board. Be sure to check actual operation, including durability, in
actual equipment before use.
High Frequency Relay G6K-RF
323
Dimensions
Note: All dimensions are in millimeters unless otherwise indicated
G6K-2F-RF
G6KU-2F-RF
Mounting Dimensions
(Top View)
Terminal Arrangement and
Internal Connections
(Top View)
Tolerance ±0.1 mm
G6K-2F-RF
7.6
Orientation mark
5.4
3.2
8
7
2
6
3
5
4
12.8
10.3
−
0.5
2.5
0.6
6.9
7.8
1.8
+
7
1
5.4
0.3
2.5
0.8
0.5
1.35
G6KU-2F-RF
(1.35)
Orientation mark
3.2
5.4
1.95
8
7
6
5
11.5
7.6
− +
S R
+ −
Note: 1. Each value has a tolerance of ±0.3 mm
2. The coplanarity of the terminals is 0.15 mm max.
1
2
3
4
G6K-2F-RF-S
G6KU-2F-RF-S
Mounting Dimensions
(Top View)
Terminal Arrangement and
Internal Connections
(Top View)
Tolerance ±0.1 mm
0.85
1.55
1.5
0.85
G6K-2F-RF-S
8.8
7.6
Orientation mark
5.4
G6K-2F-RF-S
VDC
7.8 8.6
3.2
1.2
8
7
6
5
JAPAN
1.6
−
+
10.7
10.3
2.1
1.8
7.5
7
1
2
3
4
0.6
6.9
G6KU-2F-RF-S
5.4
(1.35)
1
0.8
0.3
Orientation mark
1.8
0.5
1.35
8
7
6
5
3.2
5.4
− +
S R
7.6
+ −
Note: 1. Each value has a tolerance of ±0.3 mm
1
2
3
4
2. The coplanarity of the terminals is 0.15 mm max.
324
High Frequency Relay G6K-RF
Tape Packaging Specifications
• Add “-TR03” or “-TR09” before the coil voltage to order relays in Tape and Reel packaging. If “-TR03” or “-TR09” is not included, then the relays
will be provided in trays of 300 relays per tray.
- - Add “-TR03” to obtain 300 relays per reel
- - Add “-TR09” to obtain 900 relays per reel
1. Direction of Relay insertion
3. Carrier Tape Dimensions
G6K(U)-2F-RF
5.9 0.1
Top tape
(cover tape)
12 1.0
4
1.5+0.1 dia.
0.1
0
1.75 0.1
11.5 0.1
2
0.1
0.4 0.1
B
A
24 0.2
13.4 0.1
Carrier tape
Embossed
10.9 0.1
tape
0°
3°−1°
Pulling Direction
B-B Cross Section
B
G6K(U)-2F-RF
G6K(U)-2F-RF-S
A
Orientation mark
Orientation mark
4.25 0.1
0°
3°−1°
Pulling
direction
Pulling
direction
A-A Cross Section
8.5 0.1
G6K(U)-2F-RF-S
2. Reel Dimensions
5.9 0.1
12 0.1
4
0.1
1.5+0.1 dia.
1.75 0.1
0
2
0.1
0.4 0.05
B
A
29.5
1
25.5 0.5
11.5 0.1
24 0.3
13 0.2 dia.
21 0.8 dia.
2
0.5
11.3 0.1
A
3° max.
B-B Cross Section
B
330 80
A
3° max.
9.2 0.1
R1
Enlarged View of Section A
A-A Cross Section
High Frequency Relay G6K-RF
325
Precautions
■ Recommended Soldering Method
1. Temperature Profile for Lead Solder (Measured at the PCB)
2. Temperature Profile for Lead-free Solder (Measured at the PCB)
Case top panel
(peak): 255°C max.
Soldering
250 max.
Soldering
220 to
245
230
180
180 to
200
Preheating
150
Preheating
150
Relay terminal
section
120 max.
30 max.
Time (s)
90 to 120
20 to 30
Time (s)
3. The thickness of cream solder to be applied should be between 200 and 250 μm and the land pattern should be based on Omron’s recommended
PCB pattern. To maintain the correct soldering joint shown in the following diagram, we recommend applying solder using the soldering conditions
shown above. Check the soldering in the actual mounting conditions prior to use.
Relay
Terminal
Solder
Excessive
amount of
solder
Insufficient
amount of
solder
PCB
Land
■ Precautions for correct use
For general precautions, refer to Omron’s Relay Technical guidelines, contained in Omron’s relay catalog.
Relay Handling
Claw Securing Force During Automatic Mounting
Do not unpack the relay until ready to mount it. Use the relay as soon as
possible after opening the moisture-proof bag. Otherwise, the terminals
may tarnish and seal failure may occur after the solder process.
During automatic insertion of relays, make sure to set the securing
force of each claw to the following so that the relay’s characteristics
will be maintained.
When washing the product after soldering, use a water-based or
alcohol-based solvent. Keep the solvent temperature below 40°C.
Do not put the relay in a cold cleaning bath immediately after soldering.
C
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
B
Operating, Storage Environment
Secure the claws to the shaded area. Do not
attach them to the center of the relay or just
one part of the relay.
If the relay is stored for a long time in an adverse environment with high
temperature, high humidity, organic or sulfide gases, then sulfide or
oxide films will form on the contact surfaces. These films may result in
unstable contact, contact problems or function problems. Therefore,
operate, store or transport the product under specified environmental
conditions.
Maximum Allowable Voltage
The maximum allowable voltage of the coil can be obtained from the
coil temperature increase and the heat-resisting temperature of the
coil insulating sheath material. (Exceeding the heat-resisting tem-
perature may result in burning or short-circuiting.) The maximum
allowable voltage also involves important restrictions which include
the following;
1. Use in locations where the relay is not exposed to corrosive
gas such as hydrogen sulfide gas or salty air.
2. Use in locations where no visible dust exists.
3. Use in locations where the product is not exposed to direct
sunlight, rain or snow.
4. Do not apply force to the product which may result in deformation
or change in quality of the product.
•
Must not cause thermal changes in or deterioration of the insulating
material, which may result in films developing on the contacts.
• Must not cause damage to other control devices.
• Must not cause any harmful effect on people.
• Must not cause fire.
Coating
The relay mounted on the PCB may be coated or washed, but do not
apply silicone coating or detergent containing silicone, otherwise, the
silicone coating or detergent may remain on the surface of the relay.
Therefore, be sure to use the maximum allowable voltage as specified in
the catalog. As a rule, the rated voltage must be applied to the coil. A
voltage exceeding the rated value, however, can be applied to the coil
providing that the voltage is less than or equal to the maximum allowable
voltage. It must be noted that continuous voltage application to the coil
will cause a coil temperature increase which may affect characteristics
such as electrical life and coil insulation.
Latching Relay Mounting
Make sure that excess vibration or shock doesn’t set or reset the
relay during normal operation. The relay is shipped in the ‘reset’
position. Shock or vibration during shipping may require the application
of a reset signal, prior to operation.
Consider using a latching relay instead of a non-latching relay with a
continuous voltage applied to the coil.
326
High Frequency Relay G6K-RF
MEMO
High Frequency Relay G6K-RF
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
12/10
Specifications subject to change without notice
Printed in USA
Cat. No. X302-E-1
High Frequency Relay G6K-RF
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S12VDC
RF Relay, DPDT, Latched, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S12VDC-TR03
RF Relay, DPDT, Latched, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S12VDC-TR09
RF Relay, DPDT, Latched, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S24VDC
RF Relay, DPDT, Latched, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S24VDC-TR03
RF Relay, DPDT, Latched, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S24VDC-TR09
RF Relay, DPDT, Latched, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S3VDC-TR03
RF Relay, DPDT, Latched, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S3VDC-TR09
RF Relay, DPDT, Latched, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S4.5VDC
RF Relay, DPDT, Latched, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00246/img/page/G6K-2F-RF-S4_1492563_files/G6K-2F-RF-S4_1492563_2.jpg)
G6KU-2F-RF-S4.5VDC-TR03
RF Relay, DPDT, Latched, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON