G6KU-2F-RF-TR09DC12 [OMRON]

RF Relay, DPDT, Latched, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT;
G6KU-2F-RF-TR09DC12
型号: G6KU-2F-RF-TR09DC12
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

RF Relay, DPDT, Latched, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT

光电二极管
文件: 总7页 (文件大小:856K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G6K(U)-2F-RF(-S, -T)  
Surface-mounting High-frequency Relay  
Surface-mounting, 1-GHz-Band/  
3-GHz-Band, Miniature, DPDT,  
High-frequency Relay  
• Superior high-frequency characteristics (at 1 GHz), such as an isolation of  
20 dB min. between contacts of the same polarity or 30 dB min. between  
contacts of different polarity with an insertion loss of 0.2 dB max.  
• Miniaturized to 10.3 × 6.9 × 5.4 mm (L × W × H).  
• Rated power consumption of 100 mW with high sensitivity  
• Single-side stable and single-winding latching models available.  
• Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space.  
• New G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint.  
RoHS Compliant  
Model Number Legend  
G6K@-@@-@-@  
Application Examples  
• Communications equipment  
• Broadcasting and audio-visual equipment  
Test & measurement equipment  
• Medical equipment  
G
— —  
1
2 3  
4
5
K
U
1. Relay Function  
4. Special Function  
None: Single-side stable  
U: Single-winding latching  
RF: High-frequency compatible  
2
F
R
F
5. Terminal Shape  
None: Standard  
2. Number of poles/  
Contact Form  
S: Small footprint  
S
,
2: 2-pole/ DPDT (2c)  
T: Compatible with 3 GHz  
T
3. Terminal Shape  
Ordering Information  
Standard Models with Surface-mounting Terminals  
Standard Specifications  
Relay Function  
Single-side stable  
Enclosure rating  
Fully sealed  
Contact form  
Model  
Rated coil voltage  
3, 4.5, 5, 12, 24 VDC  
3, 4.5, 5, 12, 24 VDC  
Minimum packing unit  
G6K-2F-RF  
G6KU-2F-RF  
DPDT  
(2c)  
300 pcs/tray  
300 or 900 pcs/reel  
Single-winding latching  
Board space-saving model  
Relay Function  
Single-side stable  
Enclosure rating  
Contact form  
Model  
Rated coil voltage  
3, 4.5, 5, 12, 24 VDC  
3, 4.5, 5, 12, 24 VDC  
Minimum packing unit  
G6K-2F-RF-S  
G6KU-2F-RF-S  
DPDT  
(2c)  
300 pcs/tray  
300 or 900 pcs/reel  
Fully sealed  
Single-winding latching  
Compatible with 3 GHz  
Relay Function  
Single-side stable  
Enclosure rating  
Fully sealed  
Contact form  
Model  
Rated coil voltage  
3, 4.5, 5, 12, 24 VDC  
3, 4.5, 5, 12, 24 VDC  
Minimum packing unit  
G6K-2F-RF-T  
G6KU-2F-RF-T  
DPDT  
(2c)  
300 pcs/tray  
300 or 900 pcs/reel  
Single-winding latching  
Note 1. Please add the coil rated voltage (V) to the model number when ordering.  
Example: G6K-2F-RF DC3  
In addition, the delivered product and its package will be marked with voltage specification as "@@ VDC".  
Note 2. When ordering Relays in tape packing, add "-TR03" or "-TR09" to the end of the model number.  
Example: G6K-2F-RF-TR03 DC3  
Relays per reel: 300 pcs for -TR03  
: 900 pcs for -TR09  
This specification, however, is not part of the relay model number, so it is not marked on the relay case. (If "-TR03" or "-TR09" is not added to the end of the  
model number, the Relays will be provided in tray packing.)  
1
G6K(U)-2F-RF(-S, -T)  
Surface-mounting High-frequency Relay  
Ratings  
Coil: Single-side Stable (G6K-2F-RF(-S, -T))  
Must operate voltage Must release voltage Maximum voltage  
Power consumption  
Item  
Rated current  
(mA)  
Coil resistance  
(V)  
(V)  
(V)  
(Ω)  
(mW)  
Rated voltage  
3 VDC  
ꢀ of rated voltage  
33.0  
23.2  
21.1  
9.1  
91  
194  
237  
1,315  
5,220  
4.5 VDC  
5 VDC  
12 VDC  
24 VDC  
80ꢀ max.  
10ꢀ min.  
150ꢀ  
Approx. 100  
4.6  
Coil: Single-winding Latching Models (G6KU-2F-RF(-S, -T))  
Must set voltage  
(V)  
Must reset voltage  
(V)  
ꢀ of rated voltage  
Maximum voltage  
(V)  
Item  
Rated current  
(mA)  
Coil resistance  
Power consumption  
(mW)  
(Ω)  
Rated voltage  
3 VDC  
33.0  
23.2  
21.1  
9.1  
91  
194  
237  
1,315  
5,220  
4.5 VDC  
5 VDC  
12 VDC  
24 VDC  
75ꢀ max.  
75ꢀ max.  
150ꢀ  
Approx. 100  
4.6  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23•C with a tolerance of 10ꢀ.  
Note 2. The operating characteristics are measured at a coil temperature of 23•C.  
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.  
Contacts  
High-frequency Characteristics *1  
Item  
Load  
Resistive load  
Model G6K(U)-2F-RF(-S, -T)  
G6K  
(
U
)
-2F-RF-T  
125 VAC, 0.3 A  
30 VDC, 1 A  
1 GHz, 1 W *  
Item  
Frequency  
1GHz  
3GHz  
G
Rated load  
Between  
contacts of  
the same  
polarity  
Between  
contacts of  
different  
polarity  
K
U
20 dB min.  
18 dB min.  
25 dB min.  
Rated carry current  
Max. switching voltage  
Max. switching current  
1 A  
125 VAC or 60 VDC  
1A  
Isolation  
2
F
R
F
*
This value is for a V.SWR of 1.2 max. at the load.  
30 dB min.  
Insertion loss  
V.SWR  
Maximum carry power  
0.2 dB max.  
1.2 max.  
3W *2  
0.6 dB max.  
1.4 max.  
S
,
T
Maximum switching power  
1W *2  
Note 1. The impedance of the measurement system is 50 Ω.  
Note 2. The above values are initial values.  
*1.  
Contact your OMRON representative if the Relay will be used in an  
application that requires high repeatability in high-frequency  
characteristics for the microload region. (Such applications include  
testing and measurement equipment and ATE applications.)  
These values are for a V.SWR of 1.2 max. at the load.  
*2.  
Characteristics  
Relay Function  
Model  
Single-side stable models  
G6K-2F-RF(-S, -T)  
Single-winding latching models  
G6KU-2F-RF(-S, -T)  
Item  
Contact resistance *1  
Operating (set) time *2  
Release (reset) time *2  
Minimum set/reset pulse time  
Insulation resistance *3  
Between coil and  
contacts  
100 mΩ max.  
3 ms max. (approx. 1.4 ms)  
3 ms max. (approx. 1.3 ms)  
3 ms max. (approx. 1.2 ms)  
3 ms max. (approx. 1.2 ms)  
10 ms  
---  
1,000 MΩ min. (at 500 VDC)  
750 VAC, 50/60 Hz for 1 min  
Between contacts of  
different polarity  
Between contacts of the  
same polarity  
Between ground and  
coil/contacts  
750 VAC, 50/60 Hz for 1 min  
750 VAC, 50/60 Hz for 1 min  
500 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
Electrical  
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2  
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2  
1,000 m/s2  
750 m/s2  
50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)  
100,000 operations min. (at a switching frequency of 1,800 operations/hour)  
-40•C to 70•C (with no icing or condensation)  
5ꢀ to 85ꢀ  
Vibration  
resistance  
Shock  
resistance  
Durability  
Ambient operating temperature  
Ambient operating humidity  
Weight  
Approx. 0.95 g  
Note. The above values are initial values.  
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.  
*2. Values in parentheses are actual values.  
*3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.  
2
G6K(U)-2F-RF(-S, -T)  
Surface-mounting High-frequency Relay  
Engineering Data  
G6K-2F-RF  
Agile HP 8753D  
Vector Network  
Analyzer  
50Ω  
terminaltion  
HP8753D  
High-frequency Characteristics  
(Isolation) *1, *2  
High-frequency Characteristics  
(Insertion Loss) *1, *2  
High-frequency Characteristics  
(Return Loss, V.SWR) *1, *2  
G6K-2F-RF  
G6K-2F-RF  
G6K-2F-RF  
Average value (initial)  
Average value (initial)  
Average value (initial)  
0
0
V
·
S
W
R
1.8  
1.7  
0
Test subject: G6K-2F-RF  
Number of Relays: 10 pcs  
Test subject: G6K-2F-RF  
Test subject: G6K-2F-RF  
Number of Relays: 10 pcs  
Number of Relays: 5 pcs  
10  
10  
0.1  
20  
30  
40  
50  
60  
70  
1.6  
1.5  
1.4  
1.3  
1.2  
20  
30  
0.2  
0.3  
40  
50  
60  
Return loss  
V.SWR  
0.4  
0.5  
80  
90  
1.1  
1.0  
70  
80  
G
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
K
U
Frequency (GHz)  
Frequency (GHz)  
Frequency (GHz)  
G6K-2F-RF-S  
G6K-2F-RF-S  
G6K-2F-RF-S  
Average value (initial)  
Average value (initial)  
Average value (initial)  
2
F
R
F
0
0
V
·
S
W
R
1.8  
1.7  
0
Test subject: G6K-2F-RF-S  
Number of Relays: 10 pcs  
Test subject: G6K-2F-RF-S  
Number of Relays: 10 pcs  
Test subject: G6K-2F-RF-S  
Number of Relays: 5 pcs  
10  
20  
30  
40  
50  
60  
70  
10  
20  
30  
40  
50  
60  
0.1  
0.2  
0.3  
1.6  
1.5  
1.4  
1.3  
1.2  
S
,
T
Return loss  
V.SWR  
0.4  
0.5  
80  
90  
1.1  
1.0  
70  
80  
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
Frequency (GHz)  
Frequency (GHz)  
Frequency (GHz)  
G6K-2F-RF-T  
G6K-2F-RF-T  
G6K-2F-RF-T  
Average value (initial)  
Average value (initial)  
Average value (initial)  
V
·
S
W
R
0
0.0  
0
2.6  
2.4  
N.O.  
N.C.  
N.O.  
N.C.  
Test subject: G6K-2F-RF-T  
Number of Relays: 5 pcs  
Test subject: G6K-2F-RF-T  
Number of Relays: 5 pcs  
N.O.  
N.C.  
Test subject: G6K-2F-RF-T  
Number of Relays: 5 pcs  
10  
20  
30  
40  
50  
60  
70  
10  
20  
30  
40  
50  
60  
0.2  
0.4  
0.6  
2.2  
2.0  
1.8  
1.6  
1.4  
Return loss  
V.SWR  
0.8  
1.0  
70  
80  
1.2  
1.0  
80  
90  
0
1
2
3
4
5
6
0
1
2
3
4
5
6
0
1
2
3
4
5
6
Frequency (GHz)  
Frequency (GHz)  
Frequency (GHz)  
Note. Refer to the G6K specifications for basic specifications not shown above.  
*1. Ambient temperature condition: 23•C  
*2. The high-frequency characteristics depend on the mounting board.  
Be sure to check operation including durability in actual equipment before use.  
3
G6K(U)-2F-RF(-S, -T)  
Surface-mounting High-frequency Relay  
Dimensions  
(Unit: mm)  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Standard Specifications  
G6K-2F-RF  
G6KU-2F-RF  
G6K-2F-RF  
7.6  
Orientation mark  
5.4  
3.2  
8
7
6
5
4
12.8  
10.3  
+
0.5  
0.6  
6.9  
7.8  
1.8  
7
2.5  
1
2
3
5.4  
0.3  
2.5  
0.8  
0.5  
1.35  
G6KU-2F-RF  
(1.35)  
Orientation mark  
3.2  
5.4  
1.95  
8
7
6
5
11.5  
7.6  
− +  
S R  
+ −  
1
2
3
4
Note 1. Each value has a tolerance of 0.3 mm.  
Note 2. The coplanarity of the terminals is 0.15 mm max.  
Note:Check carefully the coil polarity of the Relay.  
Mounting Dimensions (Top View)  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Board space-saving model  
G6K-2F-RF-S  
Tolerance: 0.1 mm  
0.85  
1.55  
1.5  
0.85  
G6KU-2F-RF-S  
G6K-2F-RF-S  
Orientation mark  
8.8  
7.6  
G
5.4  
G6K-2F-RF-S  
K
U
7.8 8.6  
3.2  
1.2  
VDC  
8
7
2
6
3
5
4
JAPAN  
1.6  
+
2
F
R
F
10.7  
10.3  
0.6  
2.1  
7.5  
1.8  
7
1
6.9  
G6KU-2F-RF-S  
Orientation mark  
S
,
5.4  
(1.35)  
0.8  
0.3  
1
1.8  
T
0.5  
1.35  
8
7
6
5
3.2  
5.4  
− +  
S R  
7.6  
+ −  
1
2
3
4
Note 1. Each value has a tolerance of 0.3 mm.  
Note 2. The coplanarity of the terminals is 0.15 mm max.  
Note:Check carefully the coil polarity of the Relay.  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Compatible with 3 GHz  
G6K-2F-RF-T  
0.85  
0.5  
0.85  
G6KU-2F-RF-T  
G6K-2F-RF-T  
7.6  
Orientation mark  
5.4  
3.2  
G6K-2F-RF-T  
VDC  
7.8  
8.6  
8
7
2
6
3
5
4
30Y1YH  
1.1  
JAPAN  
4-1.15  
4.8  
1.35  
G6K-2F-RF-T  
VDC  
12  
+
2.2  
2.2  
1
10.7  
10.3  
7
10.8  
1.1  
6.9  
4.8  
G6KU-2F-RF-T  
Orientation mark  
0.6  
5.4  
2.2 2.2  
(2.45)  
0.3  
1.35  
14-0.8  
8
7
6
5
− +  
0.5  
1.35  
S R  
3.2  
5.4  
7.6  
+ −  
1
2
3
4
Note 1. Each value has a tolerance of 0.3 mm.  
Note 2. The coplanarity of the terminals is 0.15 mm max.  
Note:Check carefully the coil polarity of the Relay.  
4
G6K(U)-2F-RF(-S, -T)  
Surface-mounting High-frequency Relay  
Tape Packing Specifications (Surface-mounting Terminal Relays)  
• Add “×-TR03” or “-TR09” to the end of the model number to order Relays in tape packing.  
If “-TR” is not added, the Relays will be provided in tray packing.  
Relays per reel: -TR03 300 pcs  
-TR09 900 pcs  
Minimun ordering unit:-TR03 300 pcs  
-TR09 900 pcs  
1. Direction of Relay Insertion  
Top tape  
(cover tape)  
Carrier tape  
Embossed tape  
Pulling Direction  
G6K(U)-2F-RF  
G6K(U)-2F-RF-S(-T)  
Orientation mark  
Orientation mark  
Pulling  
direction  
Pulling  
direction  
G
K
U
2. Reel Dimensions  
2
F
R
F
1
29.5  
25.5  
0.5  
0.2 dia.  
13  
0.8 dia.  
21  
0.5  
2
S
,
A
T
330 80  
R1  
Enlarged View of Section A  
3. Carrier Tape Dimensions  
G6K(U)-2F-RF  
G6K(U)-2F-RF-S(-T)  
0.1  
5.9  
0.1  
5.9  
1.0  
12  
0.1  
0.1  
12  
4
0.1  
1.50.1 dia.  
4
1.50.1 dia.  
0
0.1  
0.1  
1.75  
11.5  
0
0.1  
0.1  
0.1  
0.1  
1.75  
11.5  
2
0.4  
0.1  
2
0.05  
0.4  
B
B
A
A
0.2  
24  
0.3  
24  
0.1  
13.4  
0.1  
11.3  
0.1  
10.9  
ޓ
0°  
3°  
-1°  
3° max.  
B-B Cross Section  
B
B-B Cross Section  
B
A
A
0.1  
4.25  
0.1  
3° max.  
9.2  
ޓ
1°  
0°  
A-A Cross Section  
A-A Cross Section  
0.1  
8.5  
5
G6K(U)-2F-RF(-S, -T)  
Surface-mounting High-frequency Relay  
G6K(U)-2F-RF(-S, -T) Recommended Soldering Method  
Recommended Conditions for IRS Method (Surface-mounting Terminals)  
• The thickness of cream solder to be applied should be  
(1) IRS Method (Mounting Solder: Lead)  
between 200 and 250 μm and the land pattern should be  
based on OMRON’s recommended PCB pattern.  
To maintain the correct soldering joint shown in the following  
diagram, we recommend applying solder with the soldering  
conditions shown on the left.  
Soldering  
220~  
245  
Correct Soldering  
Incorrect Soldering  
180~  
200  
Relay  
Terminal  
Land  
PCB  
Preheating  
150  
Heel fillet is  
formed  
Solder  
Insufficient amount of solder  
Excessive amount of solder  
Check the soldering in the actual mounting conditions before use.  
90120  
2030  
Time (s)  
(The temperature profile indicates the temperature on the circuit board surface.)  
(2) IRS Method (Mounting Solder: Lead-free)  
Case top panel (peak):  
255°C max.  
G
Soldering  
250 max.  
230  
K
U
180  
2
F
R
F
Preheating  
120 max.  
150  
Relay terminal  
section  
S
,
T
30 max.  
Time (s)  
(The temperature profile indicates the temperature on the PCB.)  
Safety Precautions  
For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product  
Data Book.  
Correct Use  
Relay Handling  
Claw Securing Force During Automatic Mounting  
• During automatic insertion of Relays, be sure to set the  
securing force of each claw to the following so that the Relay’s  
characteristics will be maintained.  
• Use the Relay as soon as possible after opening the  
moistureproof package. If the Relay is left for a long time after  
opening the moisture-proof package, the appearance may  
suffer and seal failure may occur after the solder mounting  
process. To store the Relay after opening the moisture-proof  
package, place it into the original package and seal the  
package with adhesive tape.  
• When washing the product after soldering the Relay to a PCB,  
use a water-based solvent or alcohol-based solvent and keep  
the solvent temperature to less than 40•C. Do not put the  
Relay in a cold cleaning bath immediately after soldering.  
C
B
Direction A: 1.96 N max.  
Direction B: 4.90 N max.  
Direction C: 1.96 N max.  
Secure the claws to the shaded area. Do not attach them to the center of  
the Relay or just one part of the Relay.  
Environmental Conditions for Usage, Storage, and  
Transport  
• Avoid direct sunlight when using, storing, or transporting the  
Relay and maintain normal temperature, humidity, and  
pressure conditions.  
Coating  
• Do not use silicone coating to coat the Relay when it is  
mounted to the PCB. Do not wash the PCB after the Relay is  
mounted using detergent containing silicone. Otherwise, the  
detergent may remain on the surface of the Relay.  
Long-term, Continuous ON Contacts  
Repeatability  
• Using the Relay in a circuit where the Relay will be ON  
continuously for long periods (rather than switching) can lead  
to unstable contacts because the heat generated by the coil  
itself will affect the insulation and can cause a film to develop  
on the contact surfaces. We recommend using a latching relay  
(magnetic-holding relay) in this kind of circuit. If a single-side  
stable model must be used in this kind of circuit, we  
recommend adding fail-safe circuits in case the contact fails or  
the coil burns out.  
• Contact your OMRON representative if the Relay will be used  
in an application that requires high repeatability in  
high-frequency characteristics for the microload region. (Such  
applications include testing and measurement equipment and  
ATE applications.)  
6
G6K(U)-2F-RF(-S, -T)  
Surface-mounting High-frequency Relay  
G
K
U
2
F
R
F
S
,
T
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. K242-E1-02  
0214(0207)(O)  
7

相关型号:

G6KU-2F-RF-TR09DC3

RF Relay, DPDT, Latched, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6KU-2F-RF-TR09DC5

RF Relay, DPDT, Latched, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6KU-2F-RF-TR09DC6

RF Relay, DPDT, Latched, 0.018A (Coil), 6VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6KU-2F-RF-TR09DC9

RF Relay, DPDT, Latched, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6KU-2F-RFDC12

High Frequency Relay
OMRON

G6KU-2F-RFDC24

High Frequency Relay
OMRON

G6KU-2F-RFDC3

High Frequency Relay
OMRON

G6KU-2F-RFDC4.5

High Frequency Relay
OMRON

G6KU-2F-RFDC5

High Frequency Relay
OMRON

G6KU-2F-RFDC6

High Frequency Relay
OMRON

G6KU-2F-RFDC9

High Frequency Relay
OMRON

G6KU-2F-Y

Surface Mounting Relay with the World’s Smallest Mounting Area and a Height of Only 5.2 mm
OMRON