G6S-2F-Y-TR12VDC [OMRON]
Power/Signal Relay;型号: | G6S-2F-Y-TR12VDC |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay 继电器 |
文件: | 总8页 (文件大小:705K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PCB Relay
G6S
Surface Mounting DPDT Relay
I Long terminals for ideal for soldering and mount-
ing reliability.
I Space-saving inside-L terminal.
I High dielectric strength between coil and contacts
(2,000 VAC), and between contacts of different
polarity (1,500 VAC).
I High impulse withstand voltages between coil and
contacts, and between contacts of different polar-
ity (2,500 V, 2 10 µs: Bellcore requirements).
I Low power consumption (140 mW).
I Bifurcated crossbar contact (Au-clad) and Fully
sealed construction for high reliability.
I Applicable to IRS.
I High sealability after IRS.
I Ultra-miniature at 15 7.5 9.4 mm (L W H).
I Through-hole terminal is available
I EN60950/EN41003 Supplementary Insulation-
certified type is available.
Ordering Information
Classification
Single-side
stable
Single-winding Double-winding Single-side stable
latching
latching
EN60950/EN41003
DPDT
Fully
sealed
Through-hole terminal
G6S-2
G6SU-2
G6SK-2
G6S-2-Y
Surface mount- Inside-L
G6S-2G
G6S-2F
G6SU-2G
G6SU-2F
G6SK-2G
G6SK-2F
G6S-2G-Y
ing terminal
Outside-L
G6S-2F-Y
Note: 1. When ordering, add the rated coil voltage to the model number.
Example: G6S-2F 12 VDC
Rated coil voltage
2. When ordering tape packing, add -TR" to the model number.
Example: G6S-2F-TR 12 VDC
Tape packing
Be sure since -TR" is not part of the relay model number, it is not marked on the relay case.
Model Number Legend
G6S -
-
VDC
5
1
2
3
4
1. Relay Function
None: Single-side stable
4. Approved Standards
None: UL/CSA
U:
Single-winding latching
Y:
EN60950/EN41003
5. Rated Coil Voltage
K:
Double-winding latching
2. Contact Form
2: DPDT
4.5, 5, 12, 24 VDC
3. Terminal Shape
None: Through-hole terminal
G:
F:
Inside-L surface mounting terminal
Outside-L surface mounting terminal
58
G6S
G6S
Specifications
I Coil Ratings
Single-side Stable Type (G6S-2, G6S-2F, G6S-2G)
Rated voltage
4.5 VDC
31.0 mA
145
5 VDC
28.1 mA
178
12 VDC
11.7 mA
1,028
24 VDC
8.3 mA
2,880
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
75% max. of rated voltage
10% min. of rated voltage
200% of rated voltage at 23°C
170% of rated voltage
at 23°C
Power consumption
Approx. 140 mW
Approx. 200 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G)
Rated voltage
Rated current
Coil resistance
4.5 VDC
22.2 mA
203
5 VDC
20 mA
250
12 VDC
8.3 mA
1,440
2.12
24 VDC
6.3 mA
3,840
5.80
Coil inductance
(H) (ref. value)
Armature OFF
Armature ON
0.27
0.36
0.14
0.18
1.14
3.79
Must set voltage
Must reset voltage
Max. voltage
75% max. of rated voltage
75% max. of rated voltage
180% of rated voltage at 23°C
Approx. 100 mW
Power consumption
Approx. 150 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G)
Rated voltage
Rated current
Coil resistance
4.5 VDC
44.4 mA
101
5 VDC
40 mA
125
12 VDC
16.7 mA
720
24 VDC
12.5 mA
1,920
1.98
Coil induc- Set
tance (H)
Armature OFF 0.12
Armature ON 0.074
0.14
0.60
0.088
0.098
0.16
0.41
1.23
(ref. value)
Reset Armature OFF 0.082
Armature ON 0.14
0.46
1.34
0.54
2.23
Must set voltage
Must reset voltage
Max. voltage
75% max. of rated voltage
75% max. of rated voltage
170% of rated voltage at 23°C
140% of rated voltage
at 23°C
Power consumption
Approx. 200 mW
Approx. 300 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
Single-side Stable EN60950/EN41003 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y)
Rated voltage
5 VDC
12 VDC
16.7 mA
720
24 VDC
9.6 mA
2,504
Rated current
40 mA
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
125
75% max. of rated voltage
10% min. of rated voltage
170% of rated voltage at 23°C
170% of rated voltage
at 23°C
Power consumption
Approx. 200 mW
Approx. 230 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
59
G6S
G6S
I Contact Ratings
Load
Resistive load (cos = 1)
0.5 A at 125 VAC; 2 A at 30 VDC
Ag (Au-clad)
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
2 A
250 VAC, 220 VDC
2 A
62.5 VA, 60 W
10 µA at 10 mVDC
-6
Note P level: l60 = 0.1 x 10 /operation
I Characteristics
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
75 m max.
4 ms max. (mean value: approx. 2.5 ms; latching type: approx. 2 ms)
4 ms max. (mean value: approx. 1.5 ms; latching type: approx. 2 ms)
Operate: Approx. 0.5 ms
Release: Approx. 0.5 ms
Set/Reset: Approx. 0.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
Dielectric strength
1,000 M min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching)
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
500 VAC, 50/60 Hz for 1 min between set and reset coil (double-winding latching)
Impulse withstand voltage
2,500 V (2 x 10 µs) between coil and contacts
1,500 V (10 x 160 µs) between coil and contacts (double-winding latching)
2,500 V (2 x 10 µs) between contacts of different polarity
1,500 V (10 x 160 µs) between contacts of same polarity (conforms to FCC Part 68)
Vibration resistance
Shock resistance
Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
2
Destruction: 1,000 m/s (approx. 100G)
2
Malfunction: 750 m/s (approx. 75G)
Endurance
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr)
100,000 operations min. (0.5 A at 125 VAC, resistive load)
Ambient temperature
Ambient humidity
Weight
Operating: 40°C to 85°C (with no icing), 40°C to 70°C (double-winding latching, 24 VDC)
Operating: 5% to 85%
Approx. 2 g
I Approved Standards
UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR24825)
Model
Contact form
Coil ratings
1.5 to 48 VDC
1.5 to 24 VDC
Contact ratings
2 A, 30 VDC
0.3 A, 110 VDC
0.5 A, 125 VAC
G6S-2, G6S-2F, G6S-2G
DPDT
G6SU2, G6SK-2, G6SU-2F,
G6SU2G, G6SK-2F, G6SK-2G
EN60950/EN41003
Model
Contact form
Isolation category
Supplementary Isolation
Voltage
G6S-2-Y, G6S-2G-Y, G6S-2F-Y DPDT
250 VAC
60
G6S
G6S
Engineering Data
Maximum Switching Power
Ambient Temperature vs.
Maximum Coil Voltage
Single-side Stable
Single-winding Latching
Double-winding Latching
12 VDC max.
G6SU
AC resistive load
24 VDC
(G6S-Y, 12 VDC max.)
G6SK
12 VDC
max.
G6SK
24 VDC
24 VDC
(G6S-Y)
DC resistive load
Switching voltage (V)
Ambient temperature (°C)
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating
power voltage, not a continuous voltage.
Reference Data
Ambient Temperature vs. Switching Current
Single-side Stable
Single-winding Latching
Double-winding Latching
G6SU
12 VDC max.
G6SU
12 VDC max.
24 VDC
G6SK
12 VDC max.
24 VDC
(G6S-Y)
24 VDC
(G6S-Y, 12 VDC
max.)
G6SK
24 VDC
Ambient temperature (°C)
Ambient temperature (°C)
Recommended Soldering Time vs. Surface PCB Temperature
(The temperature profile indicates the temperature on the surface of the PCB.)
IRS
Time (s)
61
G6S
G6S
Dimensions
Note All units are in millimeters unless otherwise indicated.
Single-side Stable
G6S-2, G6S-2-Y
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Bottom View)
(Bottom View)
Tolerance: 0.1
Eight, 1-dia. holes
Orientation mark
G6S-2F, G6S-2F-Y
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Top View)
(Top View)
Tolerance: 0.1
Orientation mark
G6S-2G, G6S-2G-Y
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Top View)
(Top View)
Tolerance: 0.1
Orientation mark
62
G6S
G6S
Single-winding Latching
G6SU-2
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Bottom View)
(Bottom View)
Tolerance: 0.1
Eight, 1-dia. holes
Orientation mark
G6SU-2F
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Top View)
(Top View)
Tolerance: 0.1
7.3+0.2
Orientation mark
G6SU-2G
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Top View)
7.3+0.2
(Top View)
Tolerance: 0.1
Orientation mark
63
G6S
G6S
Double-winding Latching
G6SK-2
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Bottom View)
(Bottom View)
Tolerance: 0.1
Ten, 1-dia. holes
Orientation mark
G6SK-2F
Tolerance: 0.3
Footprint
Terminal Arrangement/
Internal Connections
(Top View)
(Top View)
Tolerance: 0.1
Orientation mark
G6SK-2G
Tolerance: 0.3
7.3+0.2
Footprint
Terminal Arrangement/
Internal Connections
(Top View)
(Top View)
Tolerance: 0.1
Orientation mark
64
G6S
G6S
I Tape Packing
When ordering, add “-TR” before the rated coil voltage for tape packing.
Tape type:TE2416R (Refer to EIAJ)
Reel type:R24E (Refer to EIAJ)
Relays per reel:400
29.5 1.0
G6S-2F, G6SU-2F, G6SK-2F, G6S-2F-Y
25.5 0.5
2 0.3
2 10.5
330
80
R1.0
13 0.2
G6S-2G, G6SU-2G, G6SK-2G, G6S-2G-Y
Cover tape
Carrier tape
Emboss tape
Orientation mark
Feed direction
Precautions
Use a DC power supply with 5% or less ripple factor to operate
the coil.
Do not reverse the polarity of the coil (+, ).
Latching types are delivered in the reset position. We recommend
that a reset voltage be applied in advance to start operation.
Do not drop the G6S or otherwise subject it to excessive shock.
Remove the relay from the packing immediately prior to usage.
Do not use the G6S where subject to strong external magnetic
fields.
Do not use the G6S where subject to magnetic particles or exces-
sive amounts of dust.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K093-E1-2D
65
相关型号:
G6S-2F-Y-TRDC5
Power/Signal Relay, DPDT, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6S-2F-Y-TRDC9
Power/Signal Relay, DPDT, Momentary, 0.022A (Coil), 9VDC (Coil), 200mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6S-2F-Y5VDC
Power/Signal Relay, 2 Form C, DPDT, 8.5VDC (Coil), 2A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output
OMRON
G6S-2F-YDC12
Power/Signal Relay, DPDT, Momentary, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6S-2F-YDC24
Power/Signal Relay, DPDT, Momentary, 0.01A (Coil), 24VDC (Coil), 230mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6S-2F-YDC6
Power/Signal Relay, DPDT, Momentary, 0.033A (Coil), 6VDC (Coil), 200mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6S-2F-YDC9
Power/Signal Relay, DPDT, Momentary, 0.022A (Coil), 9VDC (Coil), 200mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6S-2F12VDC
Power/Signal Relay, 2 Form C, DPDT, 24VDC (Coil), 2A (Contact), 220VDC (Contact), DC Input, Random, AC/DC Output,
OMRON
G6S-2F24VDC
Power/Signal Relay, DPDT, Momentary, 0.008A (Coil), 24VDC (Coil), 200mW (Coil), 2A (Contact), 220VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6S-2F5VDC
Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.028A (Coil), 5VDC (Coil), 140mW (Coil), 2A (Contact), 220VDC (Contact), DC Input, Random, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明