G6SU-2F-TRDC4.5 [OMRON]

Power/Signal Relay, DPDT, Latched, 0.022A (Coil), 4.5VDC (Coil), 100mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT;
G6SU-2F-TRDC4.5
型号: G6SU-2F-TRDC4.5
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, DPDT, Latched, 0.022A (Coil), 4.5VDC (Coil), 100mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT

光电二极管
文件: 总9页 (文件大小:1816K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G6S  
Compact, Industry-Standard 2-pole relay,  
designed to switch 2A Signal Loads.  
Surface-mounting Relay  
• Long terminals for ideal for soldering and mounting reliability. (Surface  
mounting terminal models)  
• Space-saving inside-L terminal. (Surface mounting terminal models)  
• Unique terminal structure, designed to withstand IRS soldering  
processes. (Surface mounting terminal models)  
• High dielectric strength (2,000 VAC) and impulse withstand voltage  
between coil and contacts (2,500 V, 2 × 10 μs: Telcordia requirements).  
• Ultra-miniature at 9.4 mm (H) × 7.5 mm (W) × 15 mm (L).  
• Models available with BSI (EN62368-1) supplementary insulation  
certification. (-Y type)  
RoHS Compliant  
Model Number Legend  
Application Examples  
• Telecommunication equipment  
• Measurement devices  
• Office automation machines  
• Audio-visual products.  
• Security equipment  
G6S@-@@-@  
1
2 3  
4
G
6
S
1. Relay Function  
3. Terminal Shape  
None : Single-side stable  
None : PCB terminals  
U
K
: Single-winding latching  
: Double-winding latching  
F
: Outside-L surface mounting terminals  
: Inside-L surface mounting terminals  
• Building automation equipment  
• Industrial equipment  
G
2. Number of poles/  
Contact form  
4. Approved Standards  
• Amusement equipment  
• Home appliances  
None : UL, CSA  
2: 2-pole/DPDT (2c)  
Y
: UL, CSA, BSI (EN62368-1)  
Ordering Information  
Surface mounting terminal standard models  
Packing  
Tube Packing  
Tape Packing  
Rated coil  
voltage  
Minimum  
packing unit  
Rated coil  
voltage  
Minimum  
packing unit  
Minimum ordering unit  
(tape packing)  
Enclosure rating Relay Function Contact form  
Model  
Model  
3 VDC  
3 VDC  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
G6S-2F  
G6S-2G  
G6S-2F-TR  
G6S-2G-TR  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
5 VDC  
Single-side  
stable  
G6S-2F-Y  
G6S-2G-Y  
G6S-2F-Y-TR  
G6S-2G-Y-TR  
12 VDC  
24 VDC  
3 VDC  
12 VDC  
24 VDC  
3 VDC  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
G6SU-2F  
G6SU-2G  
G6SU-2F-TR  
G6SU-2G-TR  
Fully sealed  
DPDT (2c)  
50 pcs/tube  
400 pcs/reel  
800 pcs/2 reels  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
5 VDC  
Single-winding  
latching  
G6SU-2F-Y  
G6SU-2G-Y  
G6SU-2F-Y-TR  
G6SU-2G-Y-TR  
12 VDC  
24 VDC  
3 VDC  
12 VDC  
24 VDC  
3 VDC  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
Double-winding  
latching  
G6SK-2F  
G6SK-2G  
G6SK-2F-TR  
G6SK-2G-TR  
12 VDC  
24 VDC  
12 VDC  
24 VDC  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G6S-2F DC3  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.  
Note 2.When ordering tape packing, add -TR" to the model number.  
Be sure since -TR" is n ot part of the relay model number, it is not marked on the relay case.  
Note 3.When ordering tape packing, minimum order unit is 2 reels (400 pcs × 2 = 800 pcs).  
Note 4.Surface mounting terminal (SMT) standard models are shipped in moisture-proof package.  
1
G6S  
PCB Terminal Standard Models  
Surface-mounting Relay  
Relay Function  
Contact form  
Single-side stable  
Single-winding latching  
Double-winding latching  
Minimum  
Enclosure  
rating  
packing unit  
Model  
Rated coil voltage  
3 VDC  
Model  
Rated coil voltage  
Model  
Rated coil voltage  
3 VDC  
4.5 VDC  
5 VDC  
3 VDC  
4.5 VDC  
5 VDC  
4.5 VDC  
5 VDC  
G6S-2  
G6SU-2  
G6SK-2  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
Fully sealed  
DPDT (2c)  
50 pcs/tube  
24 VDC  
G6S-2-Y  
12 VDC  
24 VDC  
G6SU-2-Y  
12 VDC  
24 VDC  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G6S-2 DC3  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.  
Note 2.PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package.  
Ratings  
Single-side Stable Model  
Contacts  
Item Rated  
Coil  
Must  
Power  
consumption  
(mW)  
Item  
Load  
Resistive load  
Bifurcated crossbar  
Must release  
voltage (V) voltage (V)  
Max.  
current resistance operate  
Contact type  
Model  
Rated voltage  
(mA)  
46.7  
31  
(Ω)  
64.3  
voltage (V)  
Contact material Ag (Au-Alloy)  
3
0.5 A at 125 VAC;  
2 A at 30 VDC  
4.5  
145  
178  
200%  
(at 23°C)  
Rated load  
G
6
S
Approx. 140  
Approx. 200  
G6S-2  
G6S-2F  
G6S-2G  
5
28.1  
11.7  
DC  
75% max. 10% min.  
75% max. 10% min.  
Rated carry  
current  
12  
24  
5
1,028  
2 A  
170%  
(at 23°C)  
8.3  
2,880  
Max. switching  
voltage  
250 VAC, 220 VDC  
2 A  
40  
125  
720  
G6S-2-Y  
G6S-2F-Y  
G6S-2G-Y  
Approx. 200  
Approx. 230  
170%  
(at 23°C)  
Max. switching  
current  
DC  
12  
24  
16.7  
9.6  
2,504  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
2.Operating characteristics are measured at a coil temperature of 23°C.  
3.The maximum voltage is the highest voltage that can be imposed on the relay coil.  
Single-winding Latching Model  
Item Rated  
Coil  
Must  
Power  
consumption  
(mW)  
Must release  
voltage (V) voltage (V)  
Max.  
current resistance operate  
Model  
Rated voltage  
(mA)  
33.3  
22.2  
20  
(Ω)  
90  
voltage (V)  
3
4.5  
203  
G6SU-2  
G6SU-2F  
G6SU-2G  
Approx. 100  
180%  
(at 23°C)  
DC  
DC  
5
12  
24  
5
250  
75% max. 75% max.  
75% max. 75% max.  
8.3  
1,440  
3,840  
178  
6.3  
Approx. 150  
Approx. 140  
28.1  
11.7  
5.8  
G6SU-2-Y  
G6SU-2F-Y  
G6SU-2G-Y  
200%  
(at 23°C)  
12  
24  
1,028  
4,114  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
2.Operating characteristics are measured at a coil temperature of 23°C.  
3.The maximum voltage is the highest voltage that can be imposed on the relay coil.  
Double-winding Latching Model  
Item Rated  
Coil  
Must  
Power  
consumption  
(mW)  
Must release  
voltage (V) voltage (V)  
Max.  
current resistance operate  
Model  
Rated voltage  
(mA)  
66.6  
44.4  
40  
(Ω)  
45  
voltage (V)  
3
4.5  
101  
125  
720  
170%  
(at 23°C)  
Approx. 200  
G6SK-2  
G6SK-2F  
G6SK-2G  
5
DC  
75% max. 75% max.  
12  
16.7  
140%  
(at 23°C)  
24  
12.5  
1,920  
Approx. 300  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
2.Operating characteristics are measured at a coil temperature of 23°C.  
3.The maximum voltage is the highest voltage that can be imposed on the relay coil.  
2
G6S  
Surface-mounting Relay  
Characteristics  
Single-winding Latching  
Single-side Stable  
G6SU-2-Y,  
Single-side Stable  
G6S-2, G6S-2F,  
G6S-2G  
Single-winding Latching Double-winding Latching  
Item  
Relay Function  
G6SU-2, G6SU-2F,  
G6SU-2G  
G6SK-2, G6SK-2F,  
G6SK-2G  
G6S-2F-Y,G6S-2G-Y,  
G6SU-2F-Y,  
G6S-2-Y  
G6SU-2G-Y  
Contact resistance *1  
Operate (set) time  
Release (reset) time  
Min. set/reset pulse width  
Insulation resistance *2  
75 mΩ max.  
4 ms max.  
4 ms max.  
10 ms  
10 ms  
1,000 MΩ min. (at 500 VDC)  
1,000 VAC, 50/60 Hz  
Between coil and contacts  
2,000 VAC, 50/60 Hz for 1 min  
2,000 VAC, 50/60 Hz for 1 min  
for 1 min  
Between contacts of different polarity  
Between contacts of the same polarity  
1,500 VAC, 50/60 Hz for 1 min  
1,000 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
500 VAC, 50/60 Hz  
for 1 min  
Between set and reset coil  
Between coil and contacts  
Between coil and contacts  
Insulation  
distance  
Clearance: 1 mm, Creepage: 1.5 mm  
Clearance: 2 mm, Creepage: 2 mm  
1,500 V (10 × 160  
μs)  
2,500 V (2 × 10 μs);  
1,500 V (10 × 160 μs)  
2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs)  
Impulse  
withstand  
voltage  
Between contacts of different polarity  
Between contacts of the same polarity  
Destruction  
Malfunction  
Destruction  
2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs)  
1,500 V (10 × 160 μs)  
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude)  
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude)  
1,000 m/s2  
Vibration  
resistance  
Shock  
resistance  
Malfunction  
750 m/s2  
Mechanical  
100,000,000 operations min. (at 36,000 operations/hr)  
Durability  
100,000 operations min. for AC (at 1,800 operations/h with rated load)  
100,000 operations min. for DC (at 1,200 operations/h with rated load)  
Electrical  
Failure rate (P level) (reference value) *3  
Ambient operating temperature  
10 μA at 10 m VDC  
G
6
S
-40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation)  
only for double-winding latching 24 VDC and -Y type 24 VDC  
Ambient operating humidity  
Weight  
5% to 85%  
Approx. 2 g  
Note: The above values are initial values.  
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.  
*2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength (except  
between the set and reset coil).  
*3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary, depending on  
switching frequency, operating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load  
conditions.  
Engineering Data  
Ambient Temperature  
vs. Maximum Voltage  
(Single-side Stable)  
Ambient Temperature  
vs. Maximum Voltage  
(Latching)  
Maximum Switching  
Durability  
Capacity  
G6S-2F(G)  
10  
500  
250  
250  
G6S  
4.5 to 12 VDC  
7
300  
G6SU  
5
200  
200  
30 VDC resistive load  
Ambient temperature 23°C  
Switching frequency: 1,200  
operations/h  
100  
3
50  
30  
150  
150  
AC resistive load  
G6SK  
12 VDC max.  
1
0.7  
G6S  
100  
G6SK  
24 VDC  
100  
24 VDC  
10  
0.5  
G6S-Y  
12 VDC max. 24 VDC  
G6S-Y  
DC resistive load  
0.3  
5
3
125 VAC resistive load  
Ambient temperature 23°C  
Switching frequency: 1,800 operations/h  
50  
0
50  
0
0.1  
1
0
10  
30  
50 70 100  
300 500 700 1,000  
Switching voltage (V)  
0.5  
1
1.5  
2
2.5  
3
40  
20  
0
20  
40  
60  
80 100  
40  
20  
0
20  
40  
60  
80 100  
Switching current (A)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil.  
Ambient Temperature  
Ambient Temperature  
vs. Switching Current  
(Single-side Stable)  
3
Ambient Temperature  
vs. Must Operate or Must  
Release Voltage  
G6S-2F(G)  
vs. Switching Current  
Shock Malfunction  
(Latching)  
G6S-2F(G)  
3
100  
Y
Sample: G6S-2F  
1,000  
Energized  
Number of Relays: 10 pcs  
800  
max.  
80  
600  
400  
200  
X
1,000  
Z
X
G6SU 12 VDC max.  
De-  
energized  
1,000  
G6S  
12 VDC max.  
min.  
2
2
G6SU 24 VDC  
G6SK  
12 VDC max.  
60  
G6S-Y  
200  
400  
600  
800  
24 VDC  
40  
max.  
X
min.  
1
1
1,000  
Z'  
1,000  
X'  
G6S  
24 VDC  
G6S-Y  
20  
Shock direction  
X
Y
G6SK 24 VDC  
X'  
Must operate voltage  
Must release voltage  
1,000  
Y'  
Unit: m/s2  
12 VDC max.  
0
Z
Z'  
0
0
Sample: G6S-2F  
40  
50  
60  
70  
80  
90  
100  
40  
50  
60  
70  
80  
90  
100  
60 40 20  
0
20  
40  
60  
80 100 120  
Number of Relays: 10 pcs  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Y'  
Conditions: Shock is applied in ±X, ±Y, and  
±Z directions three times each  
with and without energizing the  
Relays to check the number of  
contact malfunctions.  
3
G6S  
Surface-mounting Relay  
Electrical Endurance  
(with Must Operate and  
Must Release Voltage) *1  
G6S-2F(G)  
Electrical Endurance  
(with Must Operate and  
Must Release Voltage) *1  
G6S-2F(G)  
Electrical Endurance  
(Contact Resistance) *1  
G6S-2F(G)  
Electrical Endurance  
(Contact Resistance) *1  
G6S-2F(G)  
100  
1,000  
100  
1,000  
Sample: G6S-2F  
Number of Relays: 10 pcs  
Measurement conditions: NO contact - wire-spring  
relay load at 48 VDC, 120mA (with ARC-killer)  
NC contact - resistive load at 48 VDC, 60mA  
Switching frequency: 3,600 operations/h  
Sample: G6S-2F  
NO contact  
Sample: G6S-2F  
Number of Relays: 10 pcs  
Measurement conditions: NO contact - wire-spring  
relay load at 48 VDC, 120mA (with ARC-killer)  
NC contact - resistive load at 48 VDC, 60mA  
Switching frequency: 3,600 operations/h  
Sample: G6S-2F  
Number of Relays: 10 pcs  
Test conditions: 2A resistive load at  
30-VDC with an operation rate of 50%  
Switching frequency: 1,200 operations/h  
Number of Relays: 10 pcs  
Test conditions: 2A resistive load  
NC contact  
at 30-VDC with an operation rate  
of 50%  
Switching frequency: 1,200  
operations/h  
500  
500  
80  
80  
300  
300  
100  
max.  
max.  
60  
60  
min.  
Must operate voltage  
min.  
Must operate voltage  
Must release voltage  
100  
40  
40  
Contact resistance  
50  
30  
max.  
min.  
50  
30  
Contact resistance  
max.  
min.  
max.  
min.  
max.  
max.  
min.  
min.  
max.  
Must release voltage  
min.  
20  
0
20  
0
NO contact  
NC contact  
10  
50  
10  
1
50  
100  
300 500 1,000  
5,000  
100  
300 500 1,000  
5,000  
1
3
5
10  
30 50 100  
300 500  
3
5
10  
30 50 100  
300 500  
Operating frequency (×103 operations)  
Operating frequency (×103 operations)  
Operating frequency (×103 operations)  
Operating frequency (×103 operations)  
Contact Reliability Test  
(Contact Resistance) *1, *2  
G6S-2F(G)  
Must Operate and Must  
Release Time Distribution *1 Time *1  
G6S-2F(G)  
Distribution of Bounce  
G6S-2F(G)  
1,000  
60  
60  
Sample:  
G6S-2F  
Sample: G6S-2F  
Number of Relays: 50 pcs  
Sample: G6S-2F  
Number of Relays:  
50 pcs  
Must operate time  
Must release time  
NO contact  
NC contact  
Operating bounce time  
Release bounce time  
Number of Relays: 10 pcs  
Test conditions: 10 μA  
resistive load at 10 m VDC  
with an operation rate of 50%  
Switching frequency: 7,200  
operations/h  
500  
300  
40  
20  
40  
100  
max.  
max.  
50  
30  
20  
min.  
min.  
G
6
S
10  
10  
30 50 100 300 500 1,000  
10,000 50,000  
0
0.5  
1
1.5  
2
2.5  
Time (ms)  
3
0
0.5  
1
1.5  
2
2.5  
Time (ms)  
3
Operating frequency (×103 operations)  
Mutual Magnetic  
Interference  
External Magnetic  
Interference  
G6S-2F(G)  
G6S-2F(G)  
(Average value)  
(Average value)  
(Average value)  
Must operate voltage  
Must release voltage  
+30  
+30  
+20  
+30  
+20  
S
N
S
N
S
N
S
N
S
N
S
N
Initial stage Test  
+20  
+10  
0
+30  
+20  
2.22 mm  
+10  
0
+10  
0
+10  
0
10  
Sample  
20  
30  
Average value  
Not  
energized  
Initial stage  
Test  
10  
10  
10  
+30  
+20  
+10  
0
20  
30  
20  
30  
20  
30  
Sample  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
Sample: G6S-2F  
Number of Relays:10 pcs  
Sample: G6S-2F  
Number of Relays:10 pcs  
Sample: G6S-2F  
Number of Relays:10 pcs  
10  
Energized  
1,200  
800  
400  
0
400  
800 1,200  
1,200  
800 400  
0
400  
800 1,200  
1,200  
800 400  
0
400  
800 1,200  
20  
30  
Average value  
External magnetic field (A/m)  
External magnetic field (A/m)  
External magnetic field (A/m)  
High-frequency  
High-frequency  
High-frequency  
Mutual Magnetic  
Interference  
G6S-2F(G)  
Characteristics  
(Isolation) *1, *2  
G6S-2F(G) (Average value (initial))  
Characteristics  
(Insertion Loss) *1, *3  
G6S-2F(G) (Average value (initial))  
0
Characteristics  
(Return Loss, V.SWR) *1, *3  
G6S-2F(G) (Average value (initial))  
Must operate voltage  
Must release voltage  
0
0
2.5  
Sample: G6S-2F  
Sample: G6S-2F  
Number of Relays: 10 pcs  
Number of Relays: 10 pcs  
Initial stage  
Test  
4.64 mm  
5
+30  
+20  
0.4  
0.8  
1.2  
2.0  
20  
+10  
0
10  
15  
20  
1.5  
1.0  
10  
V.SWR  
40  
20  
30  
Average value  
Sample  
Not  
energized  
Initial stage  
Test  
+30  
+20  
60  
80  
Return loss  
1.6  
0.5  
0
+10  
0
25  
30  
Sample  
Sample: G6S-2F  
Number of Relays: 10 pcs  
10  
2.0  
10  
30 50 100  
300 500 1,000  
5,000  
10  
30 50 100  
300 500 1,000  
5,000  
10  
30 50 100  
300 500 1,000  
5,000  
20  
30  
Average value  
Energized  
Frequency (MHz)  
Frequency (MHz)  
Frequency (MHz)  
*1. The tests were conducted at an ambient temperature of 23°C.  
*2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary  
according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.  
*3. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including durability, in the actual machine  
before use.  
4
G6S  
Surface-mounting Relay  
Dimensions  
Mounting Dimensions (Top View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Single-side Stable  
G6S-2F  
G6S-2F-Y  
2.54  
5.08  
0.2  
0.2  
14.8  
7.3  
9.2  
2.54  
Orientation mark  
12  
10  
9
8
0.2  
9.2  
9.2  
9.2  
2.2  
0.65  
8
0.25  
+0.5  
0.3  
1
3
4
5
0.5  
5.08  
2.54  
1
Note: Check carefully the coil  
polarity of the Relay.  
Note 1. Each value has a tolerance of ±0.3 mm.  
2.54  
Note 2.The coplanarity of the terminals is 0.1 mm max.  
Mounting Dimensions (Top View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G6S-2G  
G6S-2G-Y  
0.2  
0.2  
7.3  
14.8  
Orientation mark  
2.54  
5.08  
2.54  
12  
10  
9
8
0.2  
0.65  
6.1  
2.2  
0.25  
0.5  
5.08  
1
3
4
5
+0.3  
0.5  
4.9  
2.54  
1
Note: Check carefully the coil  
polarity of the Relay.  
2.54  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2.The coplanarity of the terminals is 0.1 mm max.  
PCB Mounting Holes  
(Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
G6S-2  
G6S-2-Y  
G
6
S
2.54  
Eight, 1-dia. holes  
0.2  
0.2  
7.3  
14.8  
Orientation mark  
2.54  
1
3
4
5
0.2 0.65  
2.95  
0.1  
5.08  
12  
10  
9
8
0.5  
5.08  
0.25  
(1.11)  
Note: Check carefully the coil  
polarity of the Relay.  
5.08  
5.08  
2.54  
(1.05)  
2.54  
2.54  
2.54  
Note: Each value has a tolerance of ±0.3 mm.  
Mounting Dimensions (Top View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Single-winding Latching  
G6SU-2F  
G6SU-2F-Y  
0.2  
0.2  
14.8  
7.3  
2.54  
Orientation mark  
5.08  
2.54  
12  
10  
9
8
0.2  
9.2  
0.65  
2.2  
8
S R  
0.25  
0.5  
0.3  
0.5  
5.08  
9.2  
1
3
4
5
2.54  
1
Note: Check carefully the coil  
polarity of the Relay.  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2.The coplanarity of the terminals is 0.1 mm max.  
2.54  
Mounting Dimensions (Top View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G6SU-2G  
G6SU-2G-Y  
0.2  
0.2  
7.3  
14.8  
2.54  
Orientation mark  
5.08  
2.54  
12  
10  
9
8
0.2  
9.2  
6.1  
0.65  
2.2  
S R  
0.25  
0.5  
5.08  
1
3
4
5
1
+0.3  
0.5  
4.9  
2.54  
Note: Check carefully the coil  
polarity of the Relay.  
2.54  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2.The coplanarity of the terminals is 0.1 mm max.  
PCB Mounting Holes  
(Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
G6SU-2  
G6SU-2-Y  
2.54  
Eight, 1-dia. holes  
0.2  
0.2  
7.3  
14.8  
Orientation mark  
2.54  
1
3
4
5
0.2 0.65  
2.95  
9.2  
0.1  
S R  
5.08  
12  
10  
9
8
0.5  
5.08  
0.25  
(1.11)  
Note: Check carefully the coil  
polarity of the Relay.  
5.08  
5.08  
2.54  
(1.05)  
2.54  
2.54  
2.54  
Note: Each value has a tolerance of ±0.3 mm.  
5
G6S  
Surface-mounting Relay  
Mounting Dimensions (Top View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Double-winding Latching  
G6SK-2F  
0.2  
0.2  
14.8  
7.3  
9.2  
2.54 2.54  
5.08  
Orientation mark  
2.54  
12  
10  
9
8
7
0.2  
9.2  
0.65  
S
R
2.2  
8
0.25  
+0.5  
0.3  
1
3
4
5
6
0.5  
5.08  
2.54  
Note: Check carefully the coil  
polarity of the Relay.  
Note 1. Each value has a tolerance of ±0.3 mm.  
2.54 2.54  
1
Note 2.The coplanarity of the terminals is 0.1 mm max.  
Mounting Dimensions (Top View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G6SK-2G  
0.2  
0.2  
7.3  
14.8  
2.54 2.54  
Orientation mark  
5.08  
2.54  
12  
10  
9
8
7
0.2  
9.2  
6.1  
0.65  
S
R
2.2  
0.25  
1
3
4
5
6
0.5  
5.08  
1
+0.3  
0.5  
Note: Check carefully the coil  
polarity of the Relay.  
4.9  
2.54  
2.54 2.54  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2.The coplanarity of the terminals is 0.1 mm max.  
PCB Mounting Holes  
(Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
G6SK-2  
G
6
2.54  
Ten, 1-dia. holes  
0.2  
0.2  
7.3  
14.8  
Orientation mark  
S
2.54  
1
3
4
5
6
0.2 0.65  
2.95  
9.2  
0.1  
S
R
5.08  
(1.11)  
12  
10  
9
8
7
0.5  
5.08  
0.25  
Note: Check carefully the coil  
polarity of the Relay.  
5.08  
5.08  
2.54  
(1.05)  
2.54  
2.54 2.54  
2.54 2.54  
Note: Each value has a tolerance of ±0.3 mm.  
6
G6S  
Surface-mounting Relay  
Tube Packing and Tape Packing  
Surface mounting terminal (SMT) standard models are shipped in moisture-proof package, and PCB terminal standard types do not  
require moisture proof packaging and therefore shipped in non-moisture-proof package.  
Please refer to "Correct Use" for handling after opening moisture-proof packaging for Surface mounting terminal (SMT) models.  
2. Reel Dimensions  
(1) Tube Packing  
• Relays in tube packing are arranged so that the orientation  
mark of each Relay in on the left side.  
Be sure not to make mistakes in Relay orientation when  
mounting the Relay to the PCB.  
0.5  
25.5  
29.5  
0.3  
2
1.0  
0.2  
13  
0.5  
21  
Stopper  
(gray)  
Orientation of Relays  
Stopper  
(green)  
80 330  
R1  
Tube length: 772 mm (stopper not included)  
No. of Relays per tube: 50 pcs  
3. Carrie Tape Dimensions  
(2) Tape Packing (Surface Mounting Terminal Models)  
• When ordering Relays in tape packing, add the prefix “-TR” to  
the model number, otherwise the Relays in tube packing will  
be provided.  
G6S-2F(-Y), G6SU-2F, G6SK-2F  
0.1  
9.7  
0.1  
4
+0.1  
1.5  
0  
0.1  
1.75  
11.5  
0.1  
0.05  
0.4  
2
Relays per Reel: 400 pcs  
0.1  
G
6
S
Minimum packing unit: 2 reels (800 pcs)  
1. Direction of Relay Insertion  
0.3 15.3  
24  
0.1  
16  
Orientation mark  
Top tape  
(cover tape)  
9.7  
Pulling  
direction  
G6S-2G(-Y), G6SU-2G, G6SK-2G  
0.1  
9.7  
0.1  
4
+0.1  
1.5  
0  
0.1  
0.1  
1.75  
11.5  
0.1  
0.05  
0.4  
Carrier tape  
Embossed  
2
tape  
0.3  
24  
15.3  
0.1  
16  
7.8  
7
G6S  
Surface-mounting Relay  
Recommended Soldering Method  
• The thickness of cream solder to be applied should be within a  
range between 150 and 200 µm on OMRON’s recommended  
PCB pattern.  
(1) IRS Method (Mounting Solder: Lead)  
• In order to perform correct soldering, it is recommended that  
the correct soldering conditions be maintained as shown  
below on the left side.  
Soldering  
220 to 240  
180 to 200  
Correct Soldering  
Incorrect Soldering  
Relay  
Terminal  
Preheating  
150  
Land  
PCB  
Heel fillet  
is formed  
Solder  
Insufficient amount  
of solder  
Excessive amount  
of solder  
90 to 120  
20 to 30  
Time (s)  
(The temperature profile indicates the temperature on the circuit board  
surface.)  
Visually check that the Relay is properly soldered.  
(2) IRS Method (Mounting Solder: Lead-free)  
Uppwe surface of case  
(peak): 255°C max.  
G
6
S
Soldering  
250 max.  
230  
180  
Preheating  
150  
Relay terminal  
section  
120 max.  
30 max.  
Time (s)  
(The temperature profile indicates the temperature on the PCB.)  
Approved Standards  
Precautions  
• Please refer to “PCB Relays Common Precautions” for correct use.  
UL recognized:  
(File No. E41515)  
CSA certified: (File No. LR31928)  
Correct Use  
• Long-term Continuously ON Contacts  
Number of test  
operations  
Contact form  
DPDT (2c)  
Coil ratings  
3 to 24 VDC  
Contact ratings  
• Using the Relay in a circuit where the Relay will be ON  
continuously for long periods (without switching) can lead to  
unstable contacts because the heat generated by the coil itself  
will affect the insulation, causing a film to develop on the  
contact surfaces. We recommend using a latching relay  
(magnetic-holding relay) in this kind of circuit. If a single-side  
stable model must be used in this kind of circuit, we  
recommend using a fail-safe circuit design that provides  
protection against contact failure or coil burnout.  
3 A, 30 VDC at 40°C  
0.3 A, 110 VDC at 40°C  
0.5 A, 125 VAC at 40°C  
6,000  
BSI (EN62368-1) (File No.VC657351)  
(-Y type)  
Contact form  
DPDT (2c)  
Isolation category  
Voltage  
Supplementary Insulation  
250 VAC  
• Relay Handling  
• Use the Relay as soon as possible after opening the  
moistureproof package. (As a guideline, use the Relay within  
one week at 30°C or less and 60% RH or less.) If the Relay is  
left for a long time after opening the moisture-proof package,  
the appearance may suffer and seal failure may occur after the  
solder mounting process. To store the Relay after opening the  
moisture-proof package, place it into the original package and  
sealed the package with adhesive tape.  
• When washing the product after soldering the Relay to a PCB,  
use a water-based solvent or alcohol-based solvent, and keep  
the solvent temperature to less than 40°C. Do not put the  
Relay in a cold cleaning bath immediately after soldering.  
• Claw Securing Force During Automatic Mounting  
8
G6S  
• During automatic insertion of Relays, be sure to set the  
Surface-mounting Relay  
securing force of each claw to the following so that the Relay’s  
characteristics will be maintained.  
C
B
A
Dimension A: 1.96 N max.  
Dimension B: 4.90 N max.  
Dimension C: 1.96 N max.  
G
6
S
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. K093-E1-13  
0118(0207)(O)  
9

相关型号:

G6SU-2F-TRDC5

Power/Signal Relay, DPDT, Latched, 0.02A (Coil), 5VDC (Coil), 100mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6SU-2F-TRDC6

Power/Signal Relay, DPDT, Latched, 0.017A (Coil), 6VDC (Coil), 100mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6SU-2F-TRDC9

Power/Signal Relay, DPDT, Latched, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6SU-2F-Y12VDC

SURFACE-MOUNTING SIGNAL RELAY-G6S
ETC

G6SU-2F-Y24VDC

SURFACE-MOUNTING SIGNAL RELAY-G6S
ETC

G6SU-2F-Y4.5VDC

SURFACE-MOUNTING SIGNAL RELAY - G6S
ETC

G6SU-2F-Y5VDC

SURFACE-MOUNTING SIGNAL RELAY - G6S
ETC

G6SU-2F-YDC5

Power/Signal Relay
OMRON

G6SU-2F24VDC

Power/Signal Relay
OMRON

G6SU-2F3VDC

Power/Signal Relay
OMRON

G6SU-2FDC12

Power/Signal Relay, DPDT, Latched, 0.008A (Coil), 12VDC (Coil), 100mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON

G6SU-2FDC3

Power/Signal Relay, DPDT, Latched, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON