G6ZU-1P-A12VDC
更新时间:2024-09-18 17:45:32
品牌:OMRON
描述:RF Relay, SPDT, Latched, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 0.01A (Contact), 30VDC (Contact), 2600MHz, DC Input, AC/DC Output, Through Hole-Straight Mount
G6ZU-1P-A12VDC 概述
RF Relay, SPDT, Latched, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 0.01A (Contact), 30VDC (Contact), 2600MHz, DC Input, AC/DC Output, Through Hole-Straight Mount 射频继电器
G6ZU-1P-A12VDC 规格参数
是否无铅: | 不含铅 | 是否Rohs认证: | 符合 |
生命周期: | Obsolete | Reach Compliance Code: | unknown |
ECCN代码: | EAR99 | HTS代码: | 8536.41.00.20 |
风险等级: | 5.73 | 主体宽度: | 8.6 mm |
主体高度: | 8.9 mm | 主体长度或直径: | 20 mm |
特性阻抗: | 50 Ω | 最大线圈电流(直流): | 0.017 A |
线圈工作电压(直流): | 9 V | 线圈功率: | 200 mW |
线圈释放电压(直流): | 9 V | 线圈电阻: | 720 Ω |
最大线圈电压(直流): | 12 V | 线圈/输入电源类型: | DC |
触点(交流)最大额定R负载: | .01A@30VAC | 最大触点电流(交流): | 0.01 A |
最大触点电流(直流): | 0.01 A | 触点(直流)最大额定R负载: | .01A@30VDC |
最大触点电压(交流): | 30 V | 最大触点电压(直流): | 30 V |
触点/输出电源类型: | AC/DC | 电气寿命: | 300000 Cycle(s) |
最大插入损耗: | 0.3 dB | 最大隔离度: | 45 dB |
安装特点: | THROUGH HOLE-STRAIGHT MOUNT | 工作时间: | 10 ms |
最大工作频率: | 2600 MHz | 最高工作温度: | 70 °C |
最低工作温度: | -40 °C | 物理尺寸: | 20mm x 8.6mm x 8.9mm |
继电器动作: | LATCHED | 继电器功能: | SPDT |
继电器类型: | RF RELAY | 释放时间: | 10 ms |
表面贴装: | NO | 切换时间: | 20 ms |
端接类型: | SOLDER | 电压驻波比: | 1.3 |
Base Number Matches: | 1 |
G6ZU-1P-A12VDC 数据手册
通过下载G6ZU-1P-A12VDC数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载G6Z
Surface-mounting High-frequency Relay
Surface-mounting, 3-GHz-Band,
Miniature, SPDT, High-frequency
Relay
• Superior high-frequency characteristics, such as an isolation of
30 dB min., insertion loss of 0.5 dB max., and V.SWR of 1.5 max.
at 2.6 GHz.
• Surface-mounting terminals and superior high frequency
characteristics combined using semi triplate strip transmission
lines.
• Miniature dimensions of 20 × 8.6 × 8.9 mm (L × W × H).
• Choose from a lineup that includes single-winding latching
models (200 mW), double-winding latching models (360 mW),
and models with a reverse contact arrangement.
• Series includes models with an E-shape terminal structure (same
as existing models), and models with a Y-shape terminal
structure, allowing greater freedom with PCB design.
• Models with 75-Ω impedance and models with 50-Ω impedance are available.
RoHS Compliant
G
6
Z
■Model Number Legend
G6Z@-@@@-@@
■Application Examples
These Relays can be used for switching signals in media
equipment.
—
— — — — —
1
2 3 4 5 6
• Wire communications:
Cable TV (STB and broadcasting
infrastructure), cable modems, and
VRS (video response systems)
1. Relay Function
4. Terminal arrangement
None: Y-shape terminal
structure
None: Single-side stable
• Wireless communications:Transceivers, ham radios, car
telephones, ETC, ITS, high-level
TV, satellite broadcasting, text
U:
K:
Single-winding
latching
Double-winding
latching
E:
E-shape terminal
structure
multiplex broadcasting, pay TV,
mobile phone stations, TV
broadcasting facilities, and
5. Characteristic Impedance
2. Contact Form
1: SPDT (1c)
3. Terminal Shape
None: 75 Ω
A:
50 Ω
community antenna systems
6. Contact Arrangement
None: Standard contact
arrangement
• Public equipment:
TVs, TV games, satellite radio units,
car navigation systems
F:
Surface-mounting
terminals
• Industrial equipment:
Measuring equipment, test
equipment, and multiplex
transmission devices
P:
PCB terminals
R:
Reverse contact
arrangement
■Ordering Information
●Standard Models with PCB Terminals
Enclosure
rating
Contact
form
Terminal
arrangement impedance
Characteristic
Minmum packing
Relay Function
Model
Rated coil voltage
unit
75 Ω
G6Z-1PE
3, 4.5, 5, 9, 12, 24 VDC
3, 4.5, 5, 9, 12, 24 VDC
3, 4.5, 5, 9, 12, 24 VDC
3, 4.5, 5, 9, 12, 24 VDC
E-shape
50 Ω
G6Z-1PE-A
G6Z-1P
Singleside stable
75 Ω
Y-shape
50 Ω
G6Z-1P-A
G6ZU-1PE
G6ZU-1PE-A
G6ZU-1P
75 Ω
E-shape
50 Ω
Singlewinding
latching
SPDT
(1c)
Fully sealed
3, 4.5, 5, 9, 12, 24 VDC
3, 4.5, 5, 9, 12, 24 VDC
25 pcs/tube
75 Ω
Y-shape
50 Ω
G6ZU-1P-A
G6ZK-1PE
G6ZK-1PE-A
G6ZK-1P
75 Ω
E-shape
50 Ω
Doublewinding
latching
75 Ω
Y-shape
50 Ω
G6ZK-1P-A
Note. Please add the coil rated voltage (V) to the model number when ordering.
Example: G6Z-1PE DC3
In addition, the delivered product and its package will be marked with voltage specification as "@@VDC".
1
G6Z
Surface-mounting High-frequency Relay
●Standard Models with Surface-mounting Terminals
Minimum
ordering unit
(Tape packing)
Enclosure
rating
Contact
form
Terminal
arrangement
Characteristic
impedance
Rated coil
voltage
Minmum
packing unit
Relay Function
Model
75 Ω
50 Ω
75 Ω
50 Ω
75 Ω
50 Ω
75 Ω
50 Ω
75 Ω
50 Ω
75 Ω
50 Ω
G6Z-1FE
E-shape
Y-shape
E-shape
Y-shape
E-shape
Y-shape
G6Z-1FE-A
G6Z-1F
3, 4.5, 5, 9, 12
and 24 VDC
Singleside stable
G6Z-1F-A
G6ZU-1FE
G6ZU-1FE-A
G6ZU-1F
25 pcs/tube
(300 pcs/
reel)
Singlewinding
latching
SPDT
(1c)
3, 4.5, 5, 9, 12
and 24 VDC
Fully sealed
300 pcs/reel
G6ZU-1F-A
G6ZK-1FE
G6ZK-1FE-A
G6ZK-1F
Doublewinding
latching
3, 4.5, 5, 9, 12
and 24 VDC
G6ZK-1F-A
Note 1. Please add the coil rated voltage (V) to the model number when ordering.
Example: G6Z-1PE DC3
In addition, the delivered product and its package will be marked with voltage specification as "@@VDC".
Note 2. When ordering Relays in tape packing (surface mounting terminal models), add "-TR" to the end of the model number.
This specification, however, is not part of the relay model number, so it is not marked on the relay case. (If "-TR" is not added to the end of the model number,
the Relays will be provided in tube packing.)
Note 3. Consult your OMRON representative for reverse contact models.
G
6
Z
■Ratings
●Coil: Single-side Stable Models (G6E-2P(E), G6Z-1F(E))
Must operate voltage Must release voltage Maximum voltage
Rated current
(mA)
Coil resistance
Power consumption
(mW)
(V)
(V)
(V)
(Ω)
Raged voltage
3 VDC
% of rated voltage
66.7
44.4
40.0
22.2
16.7
8.3
45
101
4.5 VDC
5 VDC
125
75% max.
10% min.
150%
Approx. 200
9 VDC
405
12 VDC
24 VDC
720
2,880
●Coil: Single-winding Latching Models (G6ZU-1P(E), G6ZU-1F(E))
Must set voltage
Must reset voltage
(V)
Maximum voltage
(V)
Rated current
(mA)
Coil resistance
Power consumption
(mW)
(V)
(Ω)
Raged voltage
3 VDC
% of rated voltage
66.7
44.4
40.0
22.2
16.7
8.3
45
101
4.5 VDC
5 VDC
125
75% max.
75% max.
150%
Approx. 200
9 VDC
405
12 VDC
24 VDC
720
2,880
●Coil: Double-winding Latching Models (G6ZK-1P(E), G6ZK-1F(E))
Must set voltage
Must reset voltage
(V)
Maximum voltage
(V)
Rated current
(mA)
Coil resistance
Power consumption
(mW)
(V)
(Ω)
Raged voltage
3 VDC
% of rated voltage
120
80
72
40
30
15
25
56
4.5 VDC
5 VDC
69
75% max.
75% max.
150%
Approx. 360
9 VDC
225
400
1,600
12 VDC
24 VDC
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
Note 4. The voltage measurements for operate/release and set/reset are the values obtained for instantaneous changes in the voltage (rectangular wave).
2
G6Z
Surface-mounting High-frequency Relay
● Contacts
● High-frequency Characteristics *1
Item
Load
Resistive load
Frequency
900MHz
2.6GHz
10 mA at 30 VAC
10 mA at 30 VDC
10 W at 900 MHz *
TH
SMD
TH
SMD
Rated load
Item
E-shape Y-shape E-shape Y-shape E-shape Y-shape E-shape Y-shape
75 Ω
50 Ω
75 Ω
65 dB min.
60 dB min.
0.2 dB max.
35 dB
min.
45 dB
min.
30 dB
min.
40 dB
min.
Rated carry
current
Isolation
60dB min.
0.5 A
Insertion loss
(not including
substrate loss)
0.5 dB max.
0.3 dB max.
Max. switching
voltage
30 VAC, 30 VDC
0.5 A
50 Ω
0.1 dB max.
Max. switching
current
75 Ω
50 Ω
75 Ω
50 Ω
1.2 dB max.
1.1 dB max.
20.8 dB min.
26.4 dB min.
10W *2
1.5 dB max.
1.3 dB max.
14.0 dB min.
17.7 dB min.
V.SWR
*
This value is for an impedance of 50Ω or 75Ω
with a V.SWR of 1.2 max.
Return loss
Maximum carry power
Note. The above values are initial values.
*1. Contact your OMRON representative if the Relay will be used in applications that require high
repeatability with high-frequency characteristics in microload regions.
*2. These values are for an impedance of 50 Ω or 75 Ω with a V.SWR of 1.2 max.
■Characteristics
Relay Function
Model
Single-side stable models
G6Z-1P(E), G6Z-1F(E)
Single-winding latching models
G6ZU-1P(E), G6ZU-1F(E)
Double-winding latching models
G6ZK-1P(E), G6ZK-1F(E)
G
6
Z
Contact resistance *1
Operating (set) time
Release (reset) time
100 mΩ max.
10 ms max.
10 ms max.
Minimum set/reset pulse time
Insulation resistance *2
−
12 ms
100 MΩ min. (at 500 VDC)
Between Coil and
contacts
1,000 VAC, 50/60 Hz for 1 min
Dielectric
strength
Between ground and
coil/contacts
500 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
Between Contacts of
the same polarity
Destruction
Malfunction
Destruction
Malfunction
Mechanical
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
Vibration
resistance
Shock
resistance
500 m/s2
1,000,000 operations min. (at 36,000 operations/hour)
Durability
300,000 operations min. (30 VAC, 10 mA/30 VDC, 10 mA), 100,000 operations min. (900 MHz, 10 W) at a switching
frequency of 1,800 operations/hour
Electrical
Ambient operating temperature
Ambient operating humidity
Weight
-40°C to 70°C (with no icing or condensation)
5% to 85% RH
Approx. 2.8 g
Note. The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checkingthe dielectric strength.
3
G6Z
Surface-mounting High-frequency Relay
■Engineering Data
● Ambient Temperature vs. Maximum
Voltage
● Ambient Temperature vs. Must
Operate or Must Release Voltage
● Shock Malfunction
Y
250
100
Sample: G6Z-1P 5 VDC
Max. estimated value
1,000
Energized
90 Number of relays: 5 pcs
800
200
150
100
80
600
max.
X
Z
400 De-energized
1,000
1,000
70
avg.
min.
200
60
50
200
400
600
800
40
max.
1,000
Z’
1,000
X’
30
avg.
Shock direction
min.
50
0
20
X
X’
Unit:
m/s2
Y
10
0
Must operate voltage
Must release voltage
1,000
Z
Sample: G6Z-1P-A
5 VDC / 50 Ω
Number of relays: 5 pcs
Y’
Z’
−40
−20
0
20
40
60
80 100
−60 −40 −20
0
20
40
60
80 100
Y’
Conditions:Shock is applied in ±X, ±Y, and ±Z
directions three times each with and
without energizing the Relays to check
for contact malfunctions.
Ambient temperature (°C)
Ambient temperature (°C)
●
Electrical Durability (with Must Operate
and Must Release Voltage) *1, *2
●
Electrical Durability (with Must Operate
and Must Release Voltage)
100
100
Sample: G6Z-1PE 75Ω 5 VDC
Number of Relays: 5 pcs
Sample: G6Z-1PE 75Ω 5 VDC
Number of Relays: 5 pcs
Test conditions: 10 mA resistive load at 30 VAC
Switching frequency: 1,800 operations/h
Test conditions: 10 mA resistive load at 30 VDC
Switching frequency: 1,800 operations/h
80
60
40
80
60
40
G
6
Z
Must operate
Must operate
Must release
max.
min.
max.
min.
Must release
max.
min.
max.
min.
20
0
20
0
0.0001 0.001
0.01
0.1
1
10
100
0.0001 0.001
0.01
0.1
1
10
100
Operating frequency (×103 operations)
Operating frequency (×103 operations)
● Electrical Durability (Contact
Resistance) *1, *2
● Electrical Durability (Contact
Resistance) *1, *2
1,000
1,000
Sample: G6Z-1PE 75Ω 5 VDC
Sample: G6Z-1PE 75Ω 5 VDC
NO contact
NC contact
NO contact
NC contact
700
700
Number of Relays: 5 pcs
Number of Relays: 5 pcs
Test conditions: 10 mA resistive load
at 30 VAC
Test conditions: 10 mA resistive load
500
500
at 30 VDC
Switching frequency: 1,800 operations/h
300
Switching frequency: 1,800 operations/h
300
max.
100
100
*1. The tests were conducted at an ambient
temperature of 23°C.
max.
Contact resistance
70
70
Contact resistance
*2. The contact resistance data are periodically
measured reference values and are not
values from each monitoring operation.
Contact resistance values will vary according
to the switching frequency and operating
environment, so be sure to check operation
under the actual operating conditions before
use.
50
50
max.
min.
min.
max.
min.
min.
30
30
10
10
0.001 0.01
0.1
1
10
100 1,000
0.001 0.01
0.1
1
10
100 1,000
Operating frequency (×103 operations)
Operating frequency (×103 operations)
● External Magnetic Interference
(Average value)
(Average value)
(Average value)
+30
+
30
+30
S
N
S
N
S
N
+20
+20
+20
+10
0
+10
0
+10
0
−10
−10
−10
−20
−30
−20
−30
−20
−30
Sample: G6Z-1P 5 VDC
Number of Relays: 5 pcs
Must operate voltage
Must release voltage
Sample: G6Z-1P 5 VDC
Number of Relays: 5 pcs
Must operate voltage
Must release voltage
Sample: G6Z-1P 5 VDC
Number of Relays: 5 pcs
Must operate voltage
Must release voltage
−1,200 −800
−400
0
400
800 1,200
−1,200 −800
−400
0
400
800 1,200
−1,200 −800
−400
0
400
800 1,200
External magnetic field (A/m)
External magnetic field (A/m)
External magnetic field (A/m)
4
G6Z
Surface-mounting High-frequency Relay
● High-frequency Characteristics at
75Ω (Isolation) *1, *2
● High-frequency Characteristics at
75Ω (Insertion Loss) *1, *2
● High-frequency Characteristics at
75Ω (Return Loss, V.SWR) *1, *2
(Average value (initial value))
(Average value (initial value))
(Average value (initial value))
V
.
S
W
R
0
1.7
0
0
Sample:G6Z-1PE 75Ω 5 VDC
Sample:G6Z-1PE 75Ω 5 VDC
with terminating resistance
with terminating resistance
10
1.6
1.5
1.4
1.3
1.2
20
40
60
0.2
Return loss
20
30
40
50
0.4
0.6
V.SWR
80
0.8
1.0
60
70
1.1
1
Sample:G6Z-1PE 75Ω 5 VDC
N.O
N.C
N.O
N.C
N.O
N.C
with terminating resistance
100
0
500
1,000 1,500 2,000 2,500 3,000
Frequency (MHz)
0
500
1,000 1,500 2,000 2,500 3,000
Frequency (MHz)
0
500
1,000
1,500
2,000
2,500 3,000
Frequency (MHz)
● High-frequency Characteristics at
50Ω (Isolation) *1, *2
● High-frequency Characteristics at
50Ω (Insertion Loss) *1, *2
● High-frequency Characteristics at
50Ω (Return Loss, V.SWR) *1, *2
(Average value (initial value))
(Average value (initial value))
(Average value (initial value))
0
V
.
S
W
R
0
1.7
0
Sample:G6Z-1PE 75Ω 5 VDC
Sample:G6Z-1PE 75Ω 5 VDC
with terminating resistance
with terminating resistance
G
6
Z
10
1.6
1.5
1.4
1.3
1.2
20
0.2
0.4
0.6
0.8
20
30
40
50
Return loss
40
60
V.SWR
80
60
70
1.1
1
Sample:G6Z-1PE 75Ω 5 VDC
N.O
N.C
N.O
N.C
N.O
N.C
with terminating resistance
100
1.0
0
500
1,000 1,500 2,000 2,500 3,000
Frequency (MHz)
0
500
1,000 1,500 2,000 2,500 3,000
Frequency (MHz)
0
500
1,000 1,500 2,000 2,500 3,000
Frequency (MHz)
● Must Operate and Must Release Time ● Must Operate and Must Release
Distribution *1
Bounce Time Distribution *1
25
30
Must operate
Must operate
Must release time
Must release time
25
20
15
10
5
20
15
10
5
Sample: G6Z-1P 5 VDC
75Ω
Number of Relays: 32 pcs
Sample: G6Z-1P 5 VDC
75Ω
Number of Relays: 32 pcs
0
1.0
2.0
3.0
4.0
5.0
0
0.5
1.0
1.5
2.0
Time (ms)
Time (ms)
*1. The tests were conducted at an ambient temperature of 23°C.
*2. High-frequency characteristics depend on the PCB to which the Relay is mounted.
Always check these characteristics, including endurance, in the actual machine before use.
5
G6Z
Surface-mounting High-frequency Relay
■Dimensions
(Unit: mm)
●Models with PCB Terminals
G6Z-1PE
G6ZU-1PE
G6Z-1PE-R
PCB Mounting Holes (Bottom View)
Tolerance: 0.1 mm
Terminal Arrangement/Internal Connections
(Bottom View)
G6Z-1PE
Six, 1.8-dia.
Orientation mark
1
7
8
Six, 1.0-dia. holes
Three, 1.6-dia.
- +
7.62
14
13 1211
10
9
9
9
20
8.6
Three, 0.8-dia. holes
2.54
7.62
15.24
G6ZU-1PE
8.9
Orientation mark
1
7
8
3
S
-
R +
+
-
6-0.6
0.2
(Coil
terminal)
0.18
2.54
7.62
3-0.4
14
13 1211
10
7.62
15.24
G6Z-1PE-R
Orientation mark
1
7
8
-
+
G
6
Z
14
13 1211
10
Note. Each value has a tolerance of ±0.3 mm.
Note:Check carefully the coil polarity of the Relay.
G6Z-1PE-A
PCB Mounting Holes (Bottom View)
Terminal Arrangement/Internal Connections
G6ZU-1PE-A
Tolerance: 0.1 mm
(Bottom View)
G6Z-1PE-A
Nine, 1.8-dia.
Orientation mark
1
7
8
Nine, 1.0-dia. holes
- +
7.62
14
13 1211
10 9
20
8.6
2.54
7.62
15.24
G6ZU-1PE-A
8.9
Orientation mark
1
7
8
3
S
R +
-
+
-
2.54
9-0.6
0.2
(Coil
terminal)
0.18
7.62
7.62
14
13 1211
10 9
15.24
Note. Each value has a tolerance of 0.3 mm.
Note:Check carefully the coil polarity of the Relay.
G6Z-1P
PCB Mounting Holes (Bottom View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Bottom View)
G6ZU-1P
G6Z-1P
Eight, 1.8-dia.
Orientation mark
1
3
4
5
7
8
Eight, 1.0-dia. holes
Three, 1.6-dia.
-
+
7.62
14
13 12
10 9
Three, 0.8-dia. holes
20
8.6
2.54
7.62
15.24
G6ZU-1P
8.9
3
Orientation mark
1
3
4
5
7
8
S
- +
-
R +
8-0.6
3-0.4
0.2
(Coil
terminal)
0.18
2.54
7.62
7.62
14
13 12
10 9
15.24
Note. Each value has a tolerance of 0.3 mm.
Note:Check carefully the coil polarity of the Relay.
6
G6Z
Surface-mounting High-frequency Relay
G6Z-1P-A
PCB Mounting Holes (Bottom View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Bottom View)
G6ZU-1P-A
G6Z-1P-A
Eleven, 1.8-dia.
Orientation mark
1
3
4
5
7
8
Eleven, 1.0-dia. holes
-
+
7.62
14
13 12
10 9
20
8.6
2.54
7.62
15.24
G6ZU-1P-A
8.9
Orientation mark
1
3
4
5
7
8
3
S
R +
- +
-
2.54
11-0.6
0.2
(Coil
terminal)
0.18
7.62
7.62
14
13 12
10 9
15.24
Note. Each value has a tolerance of 0.3 mm.
Note:Check carefully the coil polarity of the Relay.
G6ZK-1PE
PCB Mounting Holes (Bottom View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Bottom View)
G
6
Z
Seven, 1.8-dia.
Orientation mark
1
6
7
-
+
R
Seven, 1.0-dia. holes
Three, 1.6-dia.
-
+
S
7.62
14
13 1211
10 9
8
Three, 0.8-dia. holes
20
8.6
2.54
7.62
15.24
Note:Check carefully the coil polarity of the Relay.
8.9
3
7-0.6
0.2
(Coil
0.18
2.54
7.62
3-0.4
terminal)
7.62
15.24
Note. Each value has a tolerance of 0.3 mm.
G6ZK-1PE-A
PCB Mounting Holes (Bottom View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Bottom View)
Ten, 1.8-dia.
Orientation mark
1
6
7
-
+
R
Ten, 1.0-dia. holes
-
+
S
7.62
14
13 1211
10 9
8
20
8.6
2.54
7.62
15.24
Note:Check carefully the coil polarity of the Relay.
8.9
3
2.54
10-0.6
15.24
0.2
(Coil
terminal)
0.18
7.62
7.62
Note. Each value has a tolerance of 0.3 mm.
7
G6Z
Surface-mounting High-frequency Relay
G6ZK-1P
PCB Mounting Holes (Bottom View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Bottom View)
Nine, 1.8-dia.
Orientation mark
1
3
4
5
6
7
-
+
R
Nine, 1.0-dia. holes
Three, 1.6-dia.
-
+
S
7.62
14
13 12
10 9
8
20
8.6
Three, 0.8-dia. holes
2.54
7.62
15.24
Note:Check carefully the coil polarity of the Relay.
8.9
3
9-0.6
0.2
0.18
(Coil
terminal)
2.54
7.62
3-0.4
7.62
15.24
Note. Each value has a tolerance of 0.3 mm.
G6ZK-1P-A
PCB Mounting Holes (Bottom View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Bottom View)
Twelve, 1.8-dia.
Orientation mark
1
3
4
5
6
7
G
6
Z
-
+
R
Twelve, 1.0-dia. holes.
-
+
S
7.62
14
13 12
10 9
8
20
8.6
2.54
7.62
15.24
Note:Check carefully the coil polarity of the Relay.
8.9
3
2.54
12-0.6
15.24
0.2
(Coil
terminal)
0.18
7.62
7.62
Note. Each value has a tolerance of 0.3 mm.
●Models with Surface-mounting Terminals
G6Z-1FE
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
G6ZU-1FE
Tolerance: 0.1 mm
(Top View)
G6Z-1FE
Orientation mark
15.24
14
13 1211
10
9
8
7
7.62
2.54
2.3
0.8
0.8
0.8
-
+
1
20
8.6
9.6
8.3
G6ZU-1FE
0.2
(Coil
terminal)
9.3
Orientation mark
14
6-1.1
13 1211
10
9
8
7
0.18
6-0.6
3-0.4
S
-
R +
+
-
2.54
7.62
1
15.24
Note:Check carefully the coil polarity of the Relay.
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
8
G6Z
Surface-mounting High-frequency Relay
G6Z-1FE-A
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Top View)
G6ZU-1FE-A
G6Z-1FE-A
Orientation mark
15.24
14
13 1211
10
9
8
7
7.62
2.54
2.3
-
+
1
8.3
20
8.6
9.6
G6ZU-1FE-A
9-1.1
0.2
(Coil
terminal)
9.3
Orientation mark
14
13 1211
10
9
8
7
0.18
2.54
9-0.6
S
R +
-
+
-
7.62
15.24
1
Note:Check carefully the coil polarity of the Relay.
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
G6Z-1F
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
G6ZU-1F
Tolerance: 0.1 mm
(Top View)
G
6
Z
G6Z-1F
Orientation mark
15.24
14
13 12
10
5
9
8
7
2.54
2.3
0.8
0.8
-
+
1
3
4
8.3
20
8.6
9.6
G6ZU-1F
8-1.1
0.8
0.2
(Coil
terminal)
9.3
Orientation mark
14
7.62
13 12
10
5
9
8
7
0.18
8-0.6
3-0.4
S
-
R +
+
-
2.54
7.62
1
3 4
15.24
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
Note:Check carefully the coil polarity of the Relay.
G6Z-1F-A
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
G6ZU-1F-A
Tolerance: 0.1 mm
(Top View)
G6Z-1F-A
Orientation mark
15.24
14
13 12
10
5
9
8
7
2.3
2.54
-
+
8.3
1
3
4
20
8.6
9.6
11-1.1
G6ZU-1F-A
7.62
0.2
(Coil
terminal)
9.3
Orientation mark
14
13 12
10
9
8
7
0.18
2.54
11-0.6
15.24
S
-
R +
+
-
7.62
1
3
4
5
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
Note:Check carefully the coil polarity of the Relay.
9
G6Z
Surface-mounting High-frequency Relay
G6ZK-1FE
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Top View)
Orientation mark
15.24
14
13 1211
10
9
8
7.62
2.54
-
+
2.3
0.8
0.8
0.8
S
-
+
R
1
6
7
20
8.6
9.6
8.3
Note:Check carefully the coil polarity of the Relay.
0.2
(Coil
terminal)
9.3
0.18
7-1.1
7-0.6
3-0.4
2.54
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
7.62
15.24
G6ZK-1FE-A
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Top View)
Orientation mark
15.24
7.62
14
13 1211
10
9
8
2.3
2.54
-
+
S
G
6
Z
-
+
R
20
8.6
9.6
1
6
7
8.3
Note:Check carefully the coil polarity of the Relay.
0.2
(Coil
terminal)
9.3
10-1.1
0.18
2.54
10-0.6
7.62
Note 1. Each value has a tolerance of 0.3 mm.
15.24
Note 2. The coplanarity of the terminals is 0.1 mm max.
G6ZK-1F
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Top View)
Orientation mark
15.24
14
13 12
10
9
8
7.62
2.54
-
+
S
2.3
0.8
0.8
-
+
R
1
3
4
5
6
7
20
8.6
9.6
8.3
Note:Check carefully the coil polarity of the Relay.
0.2
(Coil
terminal)
9.3
0.18
9-1.1
0.8
9-0.6
3-0.4
2.54
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
7.62
15.24
G6ZK-1F-A
Mounting Dimensions (Top View)
Terminal Arrangement/Internal Connections
Tolerance: 0.1 mm
(Top View)
Orientation mark
15.24
7.62
14
13 12
10
9
8
2.3
2.54
-
+
S
-
+
R
20
8.6
9.6
1
3
4
5
6
7
8.3
0.2
(Coil
terminal)
Note:Check carefully the coil polarity of the Relay.
9.3
12-1.1
0.18
2.54
12-0.6
15.24
7.62
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
10
G6Z
Surface-mounting High-frequency Relay
■Tube Packing and Tape Packing
2. Reel Dimensions
(1) Tube Packing
±1
33.5
• Relays in tube packing are arranged so that the orientation
mark of each Relay in on the left side.
Be sure not to make mistakes in Relay orientation when
mounting the Relay to the PCB.
±1
37.5
±0.2
13
dia.
±0.8
21
dia
±0.5
2
A
Operation of Relays
Stopper (gray)
Stopper (green)
330 80
R1
Enlarged view of A
Tube length: 530 mm (stopper not included)
No. of Relays per tube: 25 pcs
3. Carrier Tape Dimensions
(2) Tape Packing (Surface-mounting Terminal Models)
• When ordering Relays in tape packing, add the prefix “-TR” to
the model number, otherwise the Relays in tube packing will
be provided.
±0.1
10
±0.1
16
4
±0.1
1.5+0.1 dia.
±0.1
±0.1
1.75
14.2
±0.1
±0.05
2
0.5
0
±0.1
±0.1
±0.1
20.6
28.4
22.6
Relays per Reel: 300 pcs
±0.3
32
Minimum packing unit: 1 Reel (300 pcs)
1. Direction of Relay Insertion
Pulling direction
5°MAX
±0.1
10.2
1.5+0.1
A
0
1.7+0.15
0
G
6
Z
Orientation mark
±0.1
4
5°MAX
0.2
Top tape
(cover tape)
R0.75
Enlarged view of A
Pulling
direction
Note. The radius of the unmarked corner is 0.3 mm.
Carrier tape
Emboss
tape
■Recommended Soldering Method
●Temperature Conditions for IRS Method
• When using reflow soldering, ensure that the Relay terminals
and the top of the case stay below the following curve. Check
that these conditions are actually satisfied before soldering the
terminals.
• The thickness of cream solder to be applied should be
between 150 and 200 μm on OMRON’s recommended PCB
pattern.
Correct Soldering
Incorrect Soldering
Relay
T4
T3
Terminal
Land
PCB
Heel fillet
is formed
T2
T1
Solder
Insufficient amount of solder
Excessive amount of solder
Check the soldering in the actual mounting conditions before
use.
t
2
t
1
Time
Soldering
Preheating
Preheating
(T1→T2, t1)
Soldering
(T3, t2)
Maximum peak
(T4)
Measured part
150→180°C,
230°C min,
30 s max.
Terminals
250°C max.
255°C max.
120 s max.
Top of case
−
−
• Do not quench the terminals after mounting. Clean the Relay
using alcohol or water no hotter than 40°C max.
11
G6Z
Surface-mounting High-frequency Relay
■Precautions
●For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product
Data Book.
Substrate Types
Material:FR-4 glass epoxy (glass cloth impregnated with epoxy
resin and copper laminated to its outer surface)
Thickness: 1.6 mm
Correct Use
● High-frequency Characteristics Measurement Method
and Measurement Substrate
• High-frequency characteristics for the G6Z are measured in
the way shown below. Consult your OMRON representative for
details on 50-Ω models.
Thickness of copper plating: 18 μm
Note 1. The compensation substrate is used when measuring the Relay’s
insertion loss. The insertion loss is obtained by subtracting the measured
value for the compensation substrate from the measured value with the
Relay mounted to the high-frequency measurement substrate.
Note 2. For convenience, the diagrams of the high-frequency measurement
substrates given here apply both to models with an E-shape terminal
structure and to models with a Y-shape terminal structure.
Note 3. Be sure to mount a standoff tightly to the through-hole substrate.
Note 4. Use measuring devices, connectors, and substrates that are
appropriate for 50Ω and 75Ω respectively.
Measurement Method for 75-Ω Models
G6Z
Network vector analyzer
(Agilent Technologies)
75-Ω
terminating
Note 5. Ensure that there is no pattern under the Relay. Otherwise, the
impedance may be adversely affected and the Relay may not be able
to attain its full characteristics.
resistance
HP8753D
50-Ω/75-Ω adapter
(Agilent Technologies)
11852B-004
●Handling
• Do not use the Relay if it has been dropped. Dropping the
Relay may adversely affect its functionality.
Through-hole Substrate (75-Ω Models, E-shape or Y-shape)
40
30
0.4
1.4
4-dia.
through-hole
• Protect the Relay from direct sunlight and keep the Relay
under normal temperature, humidity, and pressure.
• Use the Relay as soon as possible after opening the
moistureproof package. If the Relay is left for a long time after
opening the moisture-proof package, the appearance may
suffer and seal failure may occur after the solder mounting
process. To store the Relay after opening the moisture-proof
package, place it into the original package and sealed the
package with adhesive tape.
(Unit: mm)
G
6
Z
3.59
40 30
1
0.95
6.3
• When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the relay
in a cold cleaning bath immediately after soldering.
0.6-dia.
through-hole
●Claw Securing Force During Automatic Mounting
• During automatic insertion of Relays, be sure to set the
securing force of each claw to the following so that the Relay’s
SMD-type Substrate (75-Ω Models, E-shape or Y-shape)
40
4-dia.
through-hole
30
characteristics will be maintained.
1.4
C
(Unit: mm)
0.4
B
Direction A: 4.90 N max.
0.6-dia.
through-hole
Direction B: 4.90 N max.
Direction C: 4.90 N max.
Secure the claws to the shaded area. Do not attach them to the center
area or to only part of the Relay.
40 30
3.91
1
0.95
6.3
●Latching Relay Mounting
• Make sure that the vibration or shock that is generated from
other devices, such as Relays, on the same panel or substrate
and imposed on the Latching Relay does not exceed the rated
value, otherwise the set/reset status of the Latching Relay may
be changed. The Latching Relay is reset before shipping. If
excessive vibration or shock is imposed, however, the Latching
Relay may be set accidentally. Be sure to apply a reset signal
before use.
Substrate for High-frequency Characteristic Compensation
(75-Ω Models, E-shape or Y-shape)
30.7
4-dia.
(Unit: mm)
20
through-hole
●Coating
• Do not use silicone coating to coat the Relay when it is
mounted to the PCB. Do not wash the PCB after the Relay is
mounted using detergent containing silicone. Otherwise, the
detergent may remain on the surface of the Relay.
0.6-dia.
through-hole
1
0.95
40 30
●Repeatability
• Contact your OMRON representative if the Relay will be used
in an application that requires high repeatability in
high-frequencycharacteristics for the microload region. (Such
applications include testing and measurement equipment and
ATE applications.)
12
G6Z
Surface-mounting High-frequency Relay
G
6
Z
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K124-E1-04
0214(0207)(O)
13
G6ZU-1P-A12VDC 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
G6ZU-1P-A3VDC | OMRON | RF Relay, SPDT, Latched, 0.067A (Coil), 3VDC (Coil), 200mW (Coil), 0.01A (Contact), 30VDC (Contact), 2600MHz, DC Input, AC/DC Output, Through Hole-Straight Mount | 获取价格 | |
G6ZU-1P-A9VDC | OMRON | RF Relay, SPDT, Latched, 0.022A (Coil), 9VDC (Coil), 200mW (Coil), 0.01A (Contact), 30VDC (Contact), 2600MHz, DC Input, AC/DC Output, Through Hole-Straight Mount | 获取价格 | |
G6ZU-1P3VDC | OMRON | RF RELAY | 获取价格 | |
G6ZU-1PE | OMRON | High-frequency Relay | 获取价格 | |
G6ZU-1PE-12VDC | OMRON | RF Relay, SPDT, Latched, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 0.01A (Contact), 30VDC (Contact), 2600MHz, DC Input, AC/DC Output, Through Hole-Straight Mount | 获取价格 | |
G6ZU-1PE-24VDC | OMRON | RF Relay, SPDT, Latched, 0.008A (Coil), 24VDC (Coil), 200mW (Coil), 0.01A (Contact), 30VDC (Contact), 2600MHz, DC Input, AC/DC Output, Through Hole-Straight Mount | 获取价格 | |
G6ZU-1PE-3VDC | OMRON | RF Relay, SPDT, Latched, 0.067A (Coil), 3VDC (Coil), 200mW (Coil), 0.01A (Contact), 30VDC (Contact), 2600MHz, DC Input, AC/DC Output, Through Hole-Straight Mount | 获取价格 | |
G6ZU-1PE-A | OMRON | High-frequency Relay | 获取价格 | |
G6ZU-1PE-A-DC24 | OMRON | POWER/SIGNAL RELAY | 获取价格 | |
G6ZU-1PE-A-DC3 | OMRON | POWER/SIGNAL RELAY | 获取价格 |
G6ZU-1P-A12VDC 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6