G7L-1A-BUBJDC6 [OMRON]

Power/Signal Relay,;
G7L-1A-BUBJDC6
型号: G7L-1A-BUBJDC6
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay,

文件: 总13页 (文件大小:3348K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G7L  
Power Relay  
A High-capacity,  
High-dielectric-strength Relay  
Compatible with Momentary  
Voltage Drops  
• No contact chattering for momentary voltage drops up to 50% of  
rated voltage.  
• Wide-range AC-activated coil that handles 100 to 120 or 200 to  
240 VAC at either 50 or 60 Hz.  
• Miniature size for maximum switching power, particularly for  
inductive loads.  
• Flame-resistance materials (UL94V-0-qualifying) used for all  
insulation material.  
• Quick-connect, screw, and PCB terminals, and DIN track  
mounting available.  
• Conforms to UL, CSA, TUV and meets IEC950.  
• Safety design with contact gap of 3 mm.  
Note. Accessories: E-bracket, Adapter, Front-connecting socket  
and Cover sold separately.  
RoHS Compliant  
G
7
L
Application Examples  
Model Number Legend  
G7L-@@-@@@  
x Compressors for air conditioners  
and heater switching controllers.  
x Switching controllers for power tools  
or motors.  
x Power controllers for water heaters.  
x Power controllers for dryers.  
x Lamp controls, motor drivers, and  
power supply switching in copy  
machines, facsimile machines, and  
other office equipment.  
— — — — —  
1 2 3 4 5  
1. Number of Poles 3. Terminal Shape  
1: 1 pole  
2: 2 poles  
4. Mounting Construction  
Blank: E-bracket  
UB : Upper bracket  
T: Quick connect  
terminals (#250)  
B: Screw terminals  
P: PCB terminals  
2. Contact Form  
A: @PST-NO  
5. Special Functions  
J
: With test button  
Model Configuration  
x Lighting controllers.  
x Power controllers for packers or  
Terminal  
Quick-connect  
terminals  
Screw terminals  
PCB terminals  
food processing equipment.  
x Magnetron control in microwaves.  
x Power controllers for Uninterruptible  
Power Supply (UPS)  
Classification  
Contact form  
SPST-NO G7L-1A-T  
DPST-NO G7L-2A-T  
SPST-NO G7L-1A-TJ  
DPST-NO G7L-2A-TJ  
SPST-NO G7L-1A-TUB  
DPST-NO G7L-2A-TUB  
SPST-NO G7L-1A-TUBJ  
DPST-NO G7L-2A-TUBJ  
G7L-1A-B  
G7L-2A-B  
E-bracket  
mounting  
(E-bracket is  
sold separately)  
G7L-1A-BJ  
G7L-2A-BJ  
G7L-1A-BUB  
G7L-2A-BUB  
G7L-1A-BUBJ  
G7L-2A-BUBJ  
With test  
button  
Upper bracket  
mounting  
With test  
button  
SPST-NO  
DPST-NO  
G7L-1A-P  
G7L-2A-P  
PCB mounting  
List of E-bracket Mounting Models  
Mounting E-brackets  
DIN Track  
Mounting  
Adapter  
Front-connecting  
Socket  
Contact  
Terminal  
form  
Model  
Test button  
G7L-1A-T  
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
SPST-NO  
Quick-  
connect  
terminals  
G7L-1A-TJ With test button  
G7L-2A-T  
G7L-2A-TJ With test button  
G7L-1A-B  
G7L-1A-BJ With test button  
G7L-2A-B  
G7L-2A-BJ With test button  
DPST-NO  
SPST-NO  
DPST-NO  
Screw  
terminals  
Note. Accessories: E-bracket (R99-07), Adapter (P7LF-D),  
Front-connecting socket (P7LF-06) and Cover  
(P7LF-C) sold separately.  
1
G7L  
Power Relay  
Ordering Information  
E-bracket/Adapter/Socket Mounting  
Quick-connect Terminal  
E-bracket/Adapter/Socket Mounting (with test button)  
Quick-connect Terminal  
Number  
of poles  
Minimum  
packing unit  
Number  
of poles  
Minimum  
packing unit  
Model  
Rated coil voltage  
Model  
Rated coil voltage  
AC: 12, 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
AC: 24, 100/120, 200/240  
DC: 12, 24, 48, 100  
1 pole  
G7L-1A-T  
G7L-2A-T  
1 pole  
G7L-1A-TJ  
G7L-2A-TJ  
20 pcs./tray  
20 pcs./tray  
AC: 12, 24, 50, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
AC: 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
2 poles  
2 poles  
Upper Bracket Mounting  
Quick-connect Terminal  
Upper Bracket Mounting (with test button)  
Quick-connect Terminal  
Number  
Model  
Minimum  
packing unit  
Number  
of poles  
Minimum  
packing unit  
Rated coil voltage  
Model  
Rated coil voltage  
of poles  
AC: 12, 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
AC: 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
1 pole  
G7L-1A-TUB  
G7L-2A-TUB  
1 pole G7L-1A-TUBJ  
2 poles G7L-2A-TUBJ  
20 pcs./tray  
20 pcs./tray  
AC: 12, 24, 50, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
AC: 12, 24, 50, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
2 poles  
E-bracket/Adapter Mounting  
Screw Terminal  
E-bracket/Adapter Mounting (with test button)  
Screw Terminal  
Number  
of poles  
Minimum  
packing unit  
Number  
of poles  
Minimum  
packing unit  
Model  
Rated coil voltage  
Model  
Rated coil voltage  
AC: 12, 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
AC: 12, 24, 100/120, 200/240  
DC: 12, 24  
1 pole  
G7L-1A-B  
G7L-2A-B  
1 pole  
G7L-1A-BJ  
G7L-2A-BJ  
20 pcs./tray  
20 pcs./tray  
G
7
AC: 12, 24, 100/120, 200/240  
DC: 12, 24, 48, 100  
AC: 24, 100/120, 200/240  
DC: 12, 24, 48, 100  
2 poles  
2 poles  
L
Upper Bracket Mounting  
Screw Terminal  
Upper Bracket Mounting (with test button)  
Screw Terminal  
Number  
Model  
Minimum  
packing unit  
Number  
of poles  
Minimum  
packing unit  
Rated coil voltage  
Model  
Rated coil voltage  
of poles  
AC: 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
AC: 24, 100/120, 200/240  
DC: 6, 12, 24, 48  
1 pole  
G7L-1A-BUB  
1 pole G7L-1A-BUBJ  
2 poles G7L-2A-BUBJ  
20 pcs./tray  
20 pcs./tray  
AC: 12, 24, 50, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
AC: 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
2 poles G7L-2A-BUB  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G7L-1A-T AC12  
PCB Mounting  
Number  
Model  
Minimum  
packing unit  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as  
on the packing will be marked as @@ VDC.  
Rated coil voltage  
of poles  
AC: 100/120, 200/240  
DC: 12, 24, 48, 100  
1 pole  
G7L-1A-P  
G7L-2A-P  
Note 2. Refer to the precautions on PCB Relays provided in General  
Information of the Relay Product Data Book, and "w -@-3" for coil  
characteristics of AC operation.  
20 pcs./tray  
AC: 24, 100/120, 200/240  
DC: 6, 12, 24, 48, 100  
2 poles  
E-bracket/Adaptor/Socket/Cover  
DIN Track Mounting Accessories  
Applicable Relay  
models  
Minimum  
packing unit  
Name  
Model  
Minimum  
packing unit  
Applicable products  
Name  
Model  
G7L-1A-T  
G7L-1A-TJ  
G7L-1A-B  
G7L-1A-BJ  
G7L-2A-T  
G7L-2A-TJ  
G7L-2A-B  
G7L-2A-BJ  
PFP-100N  
PFP-50N  
PFP-100N2  
PFP-M  
E-bracket  
R99-07  
10 pcs.  
1 pcs.  
1 pcs.  
DIN Track  
Adaptor Surface  
Connection Socket  
10 pcs.  
End plate  
Spacer  
Adapter  
P7LF-D  
PFP-S  
Note. Order the models above in increments of the minimum quantity packaged.  
G7L-1A-T  
G7L-1A-TJ  
G7L-2A-T  
G7L-2A-TJ  
Front-connecting  
Socket  
P7LF-06  
G7L-1A-B  
G7L-1A-BJ  
G7L-1A-BUB  
G7L-1A-BUBJ  
G7L-2A-B  
Cover  
P7LF-C  
1 pcs.  
G7L-2A-BJ  
G7L-2A-BUB  
G7L-2A-BUBJ  
Note. Order the models above in increments of the minimum quantity packaged.  
2
G7L  
Power Relay  
Characteristics  
Ratings  
Coil  
Contact resistance *1  
Operate time *2  
Release time *3  
50 mΩ max.  
30 ms max.  
30 ms max.  
Item  
Max.  
permissible  
voltage  
Must operate Must release  
voltage voltage  
Coil inductance (H)  
Rated  
current  
(mA)  
Coil  
Power  
consumption  
(VA-W)  
resistance  
Max.  
operating  
frequency  
Mechanical  
Rated load  
1,800 operations/hr  
1,800 operations/hr  
(Ω)  
Armature  
ON  
Armature  
OFF  
On the basis of rated voltage  
Rated voltage  
12 VAC  
142  
71  
34  
Insulation resistance *3  
1,000 MΩ min  
24 VAC  
50 VAC  
100 to 120 VAC 17.0 to 20.4  
200 to 240 VAC  
6 VDC  
12 VDC  
24 VDC  
48 VDC  
100 VDC  
75% max.  
15% min.  
110%  
Between coil and 4,000 VAC min., 50/60 Hz  
contacts  
Approx. 1.7  
to 2.5  
for 1 min  
75 V max.  
150 V max.  
18 V min.  
36 V min.  
132 V  
264 V  
Between contacts  
Dielectric  
strength  
of same polarity  
8.5 to 10.2  
2,000 VAC, 50/60 Hz for  
1 min  
Between contacts  
of different polarity  
(DPST-NO model)  
317  
158  
79  
40  
19  
18.9  
75  
303  
1220  
5260  
0.09  
0.37  
1.42  
6.1  
0.21  
0.88  
3.54  
15.3  
60.0  
75% max.  
15% min.  
110%  
Approx. 1.9  
10,000 V between coil and  
contact *4  
Impulse withstand voltage  
21.3  
10 to 55 to 10 Hz, 0.75 mm  
Destruction  
Vibration  
single amplitude  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of  
+15%/-20% for AC rated current and ±15% for DC coil resistance.  
(1.5 mm double amplitude)  
resistance  
10 to 55 to 10 Hz, 0.75 mm  
2. The inductances shown above are reference values.  
Malfunction  
single amplitude  
3. Performance characteristic data are measured at a coil temperature of 23°C.  
4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power  
voltage, measured at ambient temperature 23°C.  
(1.5 mm double amplitude)  
Destruction  
Shock  
1,000 m/s2  
100 m/s2  
resistance  
Malfunction  
5. The "to" (for example "100 to 120") represents the range of rated voltages.  
1,000,000 operations min.  
(at 1,800 operations/hr)  
100,000 operations min.  
(at 1,800 operations/hr  
under rated load)  
Mechanical  
Contacts  
Endurance  
Contact Form  
G7L-1A-T@  
G7L-1A-B@  
G7L-2A-T@  
G7L-2A-B@  
G7L-1A-P  
G7L-2A-P  
Electrical *5  
Inductive  
Inductive  
Failure rate (P level)  
(reference value *6)  
load  
Resistive  
load  
Inductive load  
Resistive  
load  
Resistive  
load  
100 mA at 5 VDC  
load  
load  
(cosφ = 0.4)  
G
7
L
(cosφ = 0.4)  
(cosφ = 0.4)  
Approx. 90 g:  
Item  
Contact type  
Quick-connect terminal  
models  
Double break  
Ag alloy  
25 A at 220 VAC  
25 A  
Contact material  
Rated load  
Rated carry current  
Weight  
Approx. 100 g:  
PCB terminal models  
Approx. 120 g:  
30 A at 220 VAC 25 A at 220 VAC  
30 A  
20 A at 220 VAC  
20 A  
Screw terminal models  
Max. switching  
voltage  
Max. switching  
current  
250 VAC  
25 A  
Note. The values given above are initial values.  
*1.  
Measurement conditions: 5 VDC, 1 A, voltage drop  
method.  
30 A  
20 A  
*2.  
Measurement conditions: Rated operating voltage applied,  
not including contact bounce.  
Note. When using B-series (screw) products, since the screw diameter of the contact terminal is M4, be careful  
that the contact current should be 20 A or less according to JET standard (electrical appliance and material  
control law of Japan).  
Ambient temperature: 23°C  
*3.  
Measurement conditions: The insulation resistance was  
measured with a 500-VDC megohmmeter at the same  
locations as the dielectric strength was measured.  
*4.  
*5.  
*6.  
JEC-212 (1981) Standard Impulse Wave Type (1.2×50  
Ambient temperature: 23°C  
This value was measured at a switching frequency of 60  
operations/min.  
μs).  
-25°C to 60°C  
Ambient operating temperature (with no icing or  
condensation)  
Ambient operating humidity  
5% to 85%  
Engineering Data  
G7L-1A-T (TJ) (TUB) (TUBJ)  
G7L-1A-B (BJ) (BUB) (BUBJ)  
G7L-2A-T (TJ) (TUB) (TUBJ)  
G7L-2A-B (BJ) (BUB) (BUBJ)  
G7L-1A-P  
Ambient Temperature vs. Operate  
and Release Voltage  
G7L-2A-P  
Maximum Switching Power  
Maximum Switching Power  
Maximum Switching Power  
G7L-1A VAC (60 Hz)  
100  
100  
50  
100  
Operate voltage  
AC resistive load  
AC inductive load  
(cosφ = 0.4)  
Release voltage  
AC resistive load  
30  
20  
AC inductive load  
(cosφ = 0.4)  
50  
AC resistive load  
50  
80  
30  
20  
30  
20  
AC inductive load  
(cosφ = 0.4)  
60  
40  
10  
10  
10  
7
5
7
5
7
5
3
3
3
20  
0
1
1
1
10  
50 70 100  
300 500 1,000  
Switching voltage (V)  
10  
50 70 100  
300 500 1,000  
10  
50 70 100  
300 500  
-40  
-20  
0
20  
40  
60  
80  
30  
30  
30  
Ambient temperature (°C)  
Switching voltage (V)  
Ambient temperature (°C)  
Endurance  
Endurance  
Endurance  
G7L-1A VDC  
500  
500  
500  
100  
Operate voltage  
Release voltage  
300  
300  
300  
80  
60  
40  
100  
100  
100  
220 VAC resistive load  
220 VAC resistive load  
70  
50  
70  
50  
70  
50  
220 VAC resistive load  
30  
30  
30  
220 VAC  
inductive load  
(cosφ = 0.4)  
220 VAC  
inductive load  
(cosφ = 0.4)  
220 VAC  
inductive load  
(cosφ = 0.4)  
20  
0
10  
10  
10  
7
5
7
5
7
5
0
5
10  
15  
20  
25  
30  
0
5
10  
15  
20  
25  
30  
0
5
10  
15  
20  
25  
30  
-40  
-20  
0
20  
40  
60  
80  
Switching current (A)  
Switching current (A)  
Switching current (A)  
Ambient temperature (°C)  
3
G7L  
Power Relay  
Ambient Temperature vs.  
Coil Temperature Rise  
G7L-1A 120 VAC (50 Hz)  
Shock Malfunction  
G7L-2A-T (TUB) 100 to 120 VAC  
G7L-1A VDC  
80  
80  
Y
N = 5  
500  
N=5  
N=5  
30 A  
15 A  
0 A  
30 A  
Test method: The value at which  
15 A  
0 A  
malfunction occurred  
was measured after  
applying shock to the  
test piece 3 times  
each in 6 directions  
along 3 axes.  
400  
300  
200  
100  
60  
40  
60  
40  
Z'  
X
2
Standard:  
100m/s  
100  
100  
200  
300  
200  
X
X'  
300  
20  
0
20  
0
Y
400  
X'  
Z
Z
500  
Z'  
400  
500  
Unit: (m/s2  
)
Y'  
-40  
-20  
0
20  
40  
60  
80  
-40  
-20  
0
20  
40  
60  
80  
Shock direction  
Y'  
Ambient temperature (°C)  
Ambient temperature (°C)  
Momentary Voltage Drop Test  
G7L-2A-T (TUB) 100 to 120 VAC  
Test Circuit  
Voltage distribution of wave e which  
chattering does not occur.  
Wave resulted from test  
8
n=10  
ON  
Without chattering  
Ch1  
6
4
2
(contact)  
OFF  
Rated  
voltage  
Ch2  
(coil)  
Ch1  
e
Ch2  
G
7
L
0
20  
40  
60  
80  
100  
On the basis of rated voltage (%)  
Characteristic variation resulted from different mounting directions  
G7L-2A-T (TUB) 100 to 120 VAC  
Operate time  
Release time  
Operate voltage  
Release voltage  
25  
35  
80  
50  
N = 5  
N = 5  
N = 5  
N = 5  
20  
30  
70  
40  
Operate time  
Release time  
25  
Operate voltage  
60  
15  
10  
5
30  
Release voltage  
20  
50  
40  
20  
15  
10  
0
0
0
0
A
A'  
B
B'  
C
C'  
A
A'  
B
B'  
C
C'  
A
A'  
B
B'  
C
C'  
A
A'  
B
B'  
C
C'  
Top  
Top  
Top  
Top  
Bottom(Standard)  
(Note)  
Bottom(Standard)  
(Note)  
Bottom(Standard)  
(Note)  
Bottom(Standard)  
(Note)  
Mounting direction  
Mounting direction  
Mounting direction  
Mounting direction  
(Note.)The mounting direction A’ deteriorates switching performance.  
Actual Load Endurance Test  
G7L-2A 100 to 200 VAC  
Operate and Release voltages  
Operate and Release voltages  
N = 5  
Contact resistance  
N = 5  
70  
Contact resistance  
70  
100  
50  
Operate  
voltage  
N = 5  
N = 5  
N = 5  
N = 5  
60  
60  
Operate voltage  
80  
60  
40  
30  
50  
40  
50  
40  
30  
20  
30  
20  
40  
20  
0
20  
10  
0
Release voltage  
Release  
voltage  
10  
0
10  
0
0.50.7  
1
3
5
7
10  
30 50  
0.50.7  
1
3
5
7
10  
30 50  
0.050.070.1  
0.3 0.5  
1
3
5
0.050.070.1  
0.3 0.5  
1
3
5
Switching operations (×104 operations)  
Switching operations (×104 operations)  
Switching operations (×104 operations)  
Switching operations (×104 operations)  
Load conditions  
• 1 φ 220 VAC  
70 A cosφ = 0.4  
Load conditions  
• 1 φ 220 VAC  
54 A cosφ = 0.79  
(Compressor Lock Test)  
20 A cosφ = 0.4  
0.2s  
1s  
Applied coil voltage: 100% of rated  
voltage  
Applied coil voltage: 100% of rated  
voltage  
0.5s  
10s  
1s  
4
G7L  
Power Relay  
G7L-2A 100 to 200 VAC  
Operate and Release voltages  
N = 5  
Operate and Release voltages  
N = 5  
Contact resistance  
Contact resistance  
70  
50  
70  
50  
N = 5  
N = 5  
N = 5  
N = 5  
Operate voltage  
60  
Operate voltage  
60  
40  
30  
20  
40  
50  
40  
50  
40  
30  
20  
Release voltage  
Release voltage  
30  
30  
20  
20  
10  
0
10  
0
10  
0
10  
0
0.50.7  
1
3
5
10  
30 50  
0.50.7  
1
3
5
10  
30 50  
0.50.7  
1
3
5
10  
30 50  
0.50.7  
1
3
5
10  
30 50  
Switching operations (×102 operations)  
Switching operations (×102 operations)  
Switching operations (×102 operations)  
Switching operations (×102 operations)  
Load conditions  
Load conditions  
• 1 φ 220 VAC  
• 1 φ 220 VAC  
70 A cosφ = 0.4  
20 A cosφ = 0.4  
25 A cosφ = 1  
0.2s  
2s  
Applied coil voltage: 75% of rated  
voltage  
Applied coil voltage: 75% of rated  
voltage  
2s  
8s  
8s  
Dimensions  
E-bracket Mounting  
Quick-connect Terminals  
Note. E-brackets are sold separately.  
G
7
L
Terminal Arrangement/  
Internal Connections  
(Top View)  
G7L-1A-T  
52.5 max.  
33.5 max.  
0.8  
50.5 max.  
6.35  
11  
0
1
53 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
G7L-2A-T  
52.5 max.  
50.5 max.  
33.5 max.  
0.8  
6.35  
6.35  
6.35  
11  
0
2
1
8
4
6
53 max.  
Mounting Holes  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
Two, 4.5-dia. hole or  
M4 tapped holes  
G7L-1A-TJ  
52.5 max.  
50.5 max.  
33.5 max.  
0.8  
(with Test Button)  
2
40 0.1  
11  
Test  
button  
0
1
4
6
53 max.  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
G7L-2A-TJ  
52.5 max.  
50.5 max.  
(with Test Button)  
33.5 max.  
0.8  
2
11  
Test  
button  
0
2
1
8
4
6
53 max.  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
5
G7L  
Adapter Mounting  
Power Relay  
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.  
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.  
Quick-connect Terminals  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G7L-1A-T  
P7LF-D  
PFP-@N  
G7L  
0
1
51.5 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
63 max.  
5
66.5 max.  
G7L-2A-T  
P7LF-D  
PFP-@N  
G7L  
0
2
1
8
51.5 max.  
4
6
Mounting Holes  
Two, M4 or 4.5-dia.  
holes  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
63 max.  
55.5 max.  
5
66.5 max.  
40 0.1  
G7L-1A-TJ  
(with Test Button)  
P7LF-D  
G
7
L
PFP-@N  
G7L  
0
1
51.5 max.  
4
6
2
Test button  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
63 max.  
55.5 max.  
5
66.5 max.  
G7L-2A-TJ  
(with Test Button)  
P7LF-D  
PFP-@N  
G7L  
0
2
1
8
51.5 max.  
4
6
2
Test button  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
63 max.  
5
66.5 max.  
Front-connecting Socket Mounting  
Quick-connect Terminals  
Note 1. The Front-connecting Socket and DIN tracks are sold separately.  
2. The Front-connecting Socket can be track-mounted or screw-mounted.  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G7L-1A-T  
P7LF-06  
PFP-@N  
2-M3.5 × 6 (coil side)  
G7L  
0
1
51.5 max.  
4
6
Mounting Holes  
Two, M4 or 4.5-dia.  
holes  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
4-M4 × 8 (contact side)  
61.5 max.  
5
65 max.  
40 0.1  
P7LF-06  
G7L-2A-T  
PFP-@N  
2-M3.5 × 6 (coil side)  
G7L  
0
2
1
8
51.5 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
4-M4 × 8 (contact side)  
61.5 max.  
65 max.  
5
6
G7L  
Power Relay  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G7L-1A-TJ  
(with Test Button)  
P7LF-06  
PFP-@N  
2-M3.5 × 6 (coil side)  
G7L  
0
1
51.5 max.  
4
6
Mounting Holes  
2
Test button  
Two, M4 or 4.5-dia.  
holes  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
61.5 max.  
65 max.  
5
4-M4 × 8 (contact side)  
40 0.1  
G7L-2A-TJ  
(with Test Button)  
P7LF-06  
PFP-@N  
2-M3.5 × 6 (coil side)  
G7L  
0
2
1
8
51.5 max.  
4
6
2
Test button  
61.5 max.  
65 max.  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
5
4-M4 × 8 (contact side)  
Upper Bracket Mounting  
Quick-connect Terminals  
G
7
L
G7L-1A-TUB  
68.5 max.  
60  
Terminal Arrangement/  
Internal Connections  
(Top View)  
50.5 max.  
33.5 max.  
6.35  
6.35  
6.35  
0.8  
11  
0
1
47 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
4.5  
G7L-2A-TUB  
68.5 max.  
60  
50.5 max.  
33.5 max.  
0.8  
11  
0
2
1
8
47 max.  
Mounting Holes  
4
6
Two, 4.5-dia. hole or  
M4 tapped holes  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
2.5  
4.5  
G7L-1A-TUBJ  
(with Test Button)  
68.5 max.  
60  
50.5 max.  
33.5 max.  
60 0.2  
2
0.8  
11  
Test  
button  
0
1
47 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
2.5  
4.5  
G7L-2A-TUBJ  
(with Test Button)  
68.5 max.  
60  
50.5 max.  
33.5 max.  
0.8  
2
6.35  
Test  
button  
11  
0
2
1
8
47 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
2.5  
4.5  
7
G7L  
E-bracket Mounting  
Power Relay  
Note. E-brackets are sold separately.  
Screw Terminals  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G7L-1A-B  
52.5 max.  
2-M3.5 × 6  
(coil side)  
2-M4 × 8  
(contact side)  
50.5 max.  
34.5 max.  
0
1
55 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
G7L-2A-B  
52.5 max.  
50.5 max.  
2-M3.5 × 6  
(coil side)  
4-M4 × 8  
(contact side)  
34.5 max.  
0
2
1
8
55 max.  
Mounting Holes  
4
6
Two, 4.5-dia. hole or  
M4 tapped holes  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
G7L-1A-BJ  
(with Test Button)  
52.5 max.  
50.5 max.  
2-M4 × 8  
2
2-M3.5 × 6  
(coil side)  
34.5 max.  
40 0.1  
(contact side)  
G
7
L
Test  
button  
0
1
55 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
G7L-2A-BJ  
52.5 max.  
50.5 max.  
(with Test Button)  
4-M4 × 8  
(contact side)  
2-M3.5 × 6  
(coil side)  
2
34.5 max.  
Test  
button  
0
2
1
8
55 max.  
4
6
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
Adapter Mounting  
Screw Terminals  
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.  
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.  
G7L-1A-B  
G7L-2A-B  
8
Terminal Arrangement/  
Internal Connections  
(Top View)  
P7LF-D  
PFP-@N  
2-M3.5 × 6 (coil side)  
G7L  
0
1
51.5 max.  
4
6
Mounting Holes  
55.5 max.  
2-M4 × 8 (contact side)  
65.5 max.  
69 max.  
5
Two, M4 or 4.5-dia.  
holes  
(No coil polarity)  
Note. Refer to page 12 for the coil  
internal connection diagram  
40 0.1  
P7LF-D  
PFP-@N  
2-M3.5 × 6 (coil side)  
G7L  
0
2
1
8
51.5 max.  
4
6
55.5 max.  
4-M4 × 8 (contact side)  
65.5 max.  
69 max.  
(No coil polarity)  
Note. Refer to page 12 for the coil  
internal connection diagram  
5
G7L  
Power Relay  
G7L-1A-BJ  
(with Test Button)  
Terminal Arrangement/  
Internal Connections  
(Top View)  
P7LF-D  
PFP-@N  
2-M3.5 × 6 (coil side)  
G7L  
0
1
51.5 max.  
4
6
Mounting Holes  
2
Test button  
Two, M4 or 4.5-dia.  
holes  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
65.5 max.  
5
69 max.  
2-M4 × 8 (contact side)  
2-M3.5 × 6 (coil side)  
40 0.1  
G7L-2A-BJ  
(with Test Button)  
P7LF-D  
PFP-@N  
G7L  
0
2
1
8
51.5 max.  
4
6
2
Test button  
65.5 max.  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
55.5 max.  
5
69 max.  
4-M4 × 8 (contact side)  
Upper Bracket Mounting  
Screw Terminals  
G
7
L
G7L-1A-BUB  
68.5 max.  
60  
2-M3.5 × 6  
(coil side)  
Terminal Arrangement/  
Internal Connections  
(Top View)  
2-M4 × 8  
(contact side)  
50.5 max.  
34.5 max.  
0
1
49 max.  
4
6
2.5  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
4.5  
G7L-2A-BUB  
68.5 max.  
60  
2-M3.5 × 6  
(coil side)  
4-M4 × 8  
(contact side)  
50.5 max.  
34.5 max.  
0
2
1
8
49 max.  
Mounting Holes  
4
6
Two, 4.5-dia. hole or  
M4 tapped holes  
2.5  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
4.5  
G7L-1A-BUBJ  
(with Test Button)  
68.5 max.  
60  
2-M3.5 × 6  
(coil side)  
60 0.2  
2-M4 × 8  
2
50.5 max.  
34.5 max.  
(contact side)  
Test  
button  
0
1
49 max.  
4
6
2.5  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
4.5  
G7L-2A-BUBJ  
(with Test Button)  
68.5 max.  
60  
2-M3.5 × 6  
(coil side)  
4-M4 × 8  
(contact side)  
50.5 max.  
34.5 max.  
2
Test  
button  
0
2
1
8
49 max.  
4
6
2.5  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
4.5  
9
G7L  
PCB Mounting  
Power Relay  
PCB Terminals  
G7L-1A-P  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1 mm  
35.5 max.  
0.8  
52.5 max.  
2.8  
6
36.8  
3.2  
0
1
47 max.  
(8.4)  
41 max.  
4
6
14.4  
1.2  
17.7  
(8.9)  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
4-1.2 × 3.2 square hole  
G7L-2A-P  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1 mm  
52.5 max.  
35.5 max.  
0.8  
2.8  
6
36.8  
3.2  
0
2
1
8
47 max.  
(8.4)  
41 max.  
4
6
14.4  
1.2  
17.7  
(8.9)  
(No coil polarity)  
Note. Refer to page 12 for the coil internal  
connection diagram  
6-1.2 × 3.2 square hole  
40  
46  
E-bracket  
R99-07 (E KANAGU)  
FOR G7L  
Two, 4.5-dia. hole  
Mounting Holes  
Two, M4 or 4.5-dia.  
holes  
26  
24 17.8  
G
7
L
40  
10  
3
24  
19.7  
7
5
30  
50  
5
4.4  
Adapter  
P7LF-D  
Mounting Holes  
Two, M4 or 4.5-dia.  
holes  
51.5 max.  
40 0.1  
40 0.1  
14.5  
5
35.2 max.  
55.5 max.  
2-M3.5 × 6 (coil side)  
8
0.05  
Front-connecting  
Socket  
Mounting Holes  
P7LF-06  
Two, M4 or 4.5-dia.  
holes  
51.5 max.  
40 0.1  
25  
9.2 0.05  
4-M4 × 8  
(contact side)  
5
46 max.  
40 0.1  
55.5 max.  
Cover  
P7LF-C  
34.5 max.  
Put the P7LF-C cover onto the terminals in order to protect the  
user from electric shock.  
1
50.5 max.  
6 max.  
10  
G7L  
Power Relay  
Approved Standards  
x A variety of Safety Standard approved products for standard models.  
UL Recognized (File No. E41643)  
EN/IEC, TÜV Certified  
(Certificate No. R50059083)  
Number of test  
operations  
Approved  
switching  
operations  
Model  
Coil ratings  
Contact ratings  
Model  
G7L-1A-B  
G7L-2A-B  
Coil ratings  
Contact ratings  
30 A, 277 VAC (RES) 40°C  
1.5 kW, 120 VAC (T) 40°C  
1.5 HP, 120 VAC 40°C  
100,000  
6,000  
1,000  
G7L-1A-T  
G7L-1A-B  
G7L-1A-P  
G7L-2A-T  
G7L-2A-B  
G7L-2A-P  
@
SPST-NO (1a)  
@
30 A, 250 VAC ~ (cos  
φ
= 1) 60°C  
= 0.4) 60°C  
= 0.4) 60°C  
@
@
50,000  
50,000  
12 to 240 VAC  
6 to 220 VDC  
25 A, 250 VAC ~ (cos  
φ
φ
3 HP 277 VAC 40°C  
100,000  
@
@
30 A, 120 VAC ~ (cos  
20 FLA/120 LRA, 120 VAC 40°C  
17 FLA/102 LRA, 277 VAC 40°C  
TV-10, 120 VAC 40°C  
30,000  
25,000  
DPST-NO (2a)  
25 A, 277 VAC ~ (cos  
φ
= 1) 60°C  
= 0.4) 60°C  
25 A, 277 VAC ~ (cos  
φ
SPST-NO (1a)  
25 A, 240 VAC ~ (cos  
25 A, 240 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
DPST-NO (2a)  
25 A, 240 VAC ~ (cos  
25 A, 240 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
SPST-NO (1a)  
20 A, 240 VAC ~ (cos  
20 A, 240 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
DPST-NO (2a)  
20 A, 240 VAC ~ (cos  
20 A, 240 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
25 A, 277 VAC ~ (cos  
CSA certified  
(File No. LR31928)  
φ
= 1) 60°C  
= 0.4) 60°C  
= 1) 60°C  
= 0.4) 60°C  
Number of test  
operations  
G7L-1A-T  
G7L-2A-T  
@
@
50,000  
50,000  
50,000  
50,000  
φ
Model  
Coil ratings  
Contact ratings  
φ
φ
6, 12, 24, 48,  
100, 110, 200,  
220 VDC  
12, 24, 50,  
100 to 120,  
200 to 240  
VAC  
2.4 kW, 120 VAC (T) 40°C  
1.5 HP, 120 VAC (T) 40°C  
3 HP 277 VAC 40°C  
20.5 FLA/105 LRA, 120 VAC 85°C  
TV-10, 120 VAC 40°C  
30 A, 277 VAC (RES) 40°C  
2.4 kW, 120 VAC (T) 40°C  
1.5 HP, 120 VAC 40°C  
6,000  
1,000  
12 to 240 VAC  
6 to 220 VDC  
G7L-1A-P  
φ
= 1) 60°C  
= 0.4) 60°C  
= 1) 60°C  
φ = 0.4) 60°C  
100,000  
25,000  
100,000  
6,000  
φ
φ
G7L-1A-T  
G7L-1A-B  
@
@
φ
= 1) 60°C  
= 0.4) 60°C  
= 1) 60°C  
= 0.4) 60°C  
12 to 240 VAC  
6 to 220 VDC  
1,000  
G7L-1A-P  
G7L-2A-P  
φ
G7L-2A-T  
G7L-2A-B  
G7L-2A-P  
@
3 HP 277 VAC 40°C  
20.5 FLA/105 LRA, 120 VAC 85°C  
TV-10, 120 VAC 40°C  
φ
@
100,000  
25,000  
φ
G
7
L
Reference  
φ
= 1) 60°C  
= 0.4) 60°C  
= 1) 60°C  
= 0.4) 60°C  
UL Approved Type ....................................................  
UL508 Industrial Control Devices  
UL1950 Information processing equipment  
(Including office equipment)  
φ
φ
φ
CSA Approved Type ..................................................  
CSA C22.2 No.1, 14  
Industrial Control Devices  
CSA C22.2 No.950 Information processing equipment  
(Including office equipment)  
TÜV EN/IEC Standard Approved Type......................  
EN61810-1 Relay  
EN60950 Information processing equipment  
(Including office equipment)  
IEC950 Information processing equipment  
(Including office equipment)  
11  
G7L  
Power Relay  
Precautions  
Please refer to “PCB Relays Common Precautions” for general precautions.  
Correct Use  
Installation  
Connecting  
When connecting with screws, if the  
screws are not sufficiently tightened,  
the lead wire can become detached  
and may lead to abnormal heating or  
fire caused by faulty contact.  
• Although there are not specific limits  
on the installation site, it should be as  
dry and dust-free as possible.  
• Using in an atmosphere of high  
temperature, high humidity and  
corrosive gas may deteriorate its  
performance characteristic caused by  
condensation or corrosive products,  
resulting in failure or burn damage of  
the Relay.  
• Refer to the following table when  
connecting a wire with a crimpstyle  
terminal to the G7L.  
Front-connecting  
Screw terminals  
• Mounting Torque  
Socket  
.
0.98N  
m
8
8
Tighten with two M4 screws when  
mounting.  
(Top bracket type)  
• Do not apply excessive force when  
mounting or dismounting the Faston  
receptacle.Insert and remove  
terminals carefully one at a time. Do  
not insert terminals at an angle, or  
insert/remove multiple terminals at the  
same time.  
• Do not connect to the terminals by  
soldering  
• Refer to the following table for  
recommendations of connectors  
made by OMRON.  
5.8  
5
6.5  
5.3  
Coil  
M3.5  
M4  
M3.5  
M4  
• PCB Terminal-equipped Relays weigh  
approximately 100 g.  
5.5  
6.5  
5.5  
7
Be sure that the PCB is strong enough  
to support them. We recommend  
dual-side through-hole PCBs to  
reduce solder cracking from heat  
stress.  
• Relays with test buttons must be  
mounted facing down.  
Be careful not to touch the test button  
accidentally. Doing so may turn ON  
the contact.  
Contact  
9.2  
9.2  
• Allow suitable slack on leads when  
wiring, and do not apply excessive  
force to the terminals.  
• Tightening torque  
G
7
L
.
.
Coil:  
0.78 to 1.18 N  
m
m
Contact: 0.98 to 1.37 N  
• Be sure to use the test button for test  
purposes only (with test-button  
models). The test button is used for  
Relay circuit tests, such as circuit  
continuity tests. Do not attempt to  
switch the load with the test button.  
Type  
Receptacle terminals  
Housing  
XT3W-S441-12  
XT3W-S442-12  
XT3W-S443-12  
#250 terminals  
(width: 6.35 mm)  
XT3B-1S white  
Note. The current should be 25 A when using receptacle terminals.  
Micro Loads  
• The G7L is used for switching power  
loads, such as motor, transformer,  
solenoid, lamp, and heater loads. Do  
not use the G7L for switching micro  
loads, such as signals.  
Reference Data  
DIN Track Mounting Adapter and  
Front-connecting Socket  
• The ratio of rated voltage between 100  
to 120 VAC are values measured on  
the basis of 100 VAC.  
(DIN Track Mounting)  
• The DIN Track Mounting Adapter and  
Front-connecting Socket can be  
mounted on the G7L with just one  
hand and dismounted with ease by  
using a screwdriver.  
Soldering PCB Terminals  
Operating Coil  
• Do not perform automatic soldering  
but solder manually.  
• Solder with the following conditions:  
Soldering iron temperature (max.)  
380°C, Soldering time within 10  
seconds.  
• Do not wash down the entire Relay  
because it does not have an airtight  
construction.  
(Coil internal connections diagram)  
• DC Coil  
To support the G7L mounted on a DIN  
Track Mounting Adapter or  
0
1
Front-connecting Socket, use the  
PFP-M End Plate. Put the End Plate  
onto the DIN Track Mounting Adapter  
or Front-connecting Socket so that the  
surface mark of the End Plate faces  
upwards. Then tighten the screw of the  
End Plate securely with a screwdriver.  
• AC Coil  
0
1
(Screw Mounting)  
• If a transistor drives the G7L check the  
leakage current, and connect a  
bleeder resistor if necessary.  
• The AC coil is provided with a built-in  
full-wave rectifier. If a triac, such as an  
SSR, drives the G7L, the G7L may not  
release. Be sure to perform a trial  
operation with the G7L and the triac  
before applying them to actual use.  
• Screw-mount the DIN Track Mounting  
Adapter or Front-connecting Socket  
securely after opening screw mounting  
holes on them.  
• When cutting or opening holes on the  
panel after the Front-connecting  
Socket is mounted, take proper  
measures so that the cutting chips will  
not fall onto the Relay terminals. When  
cutting or opening holes on the upper  
part of the panel, mask the  
Front-connecting Socket properly with  
a cover.  
12  
G7L  
Power Relay  
G
7
L
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. J055-E1-14  
1116(0207)(O)  
13