G7L-1A-TUBJAC200/240 [OMRON]
Power/Signal Relay;型号: | G7L-1A-TUBJAC200/240 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay |
文件: | 总13页 (文件大小:3348K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G7L
Power Relay
A High-capacity,
High-dielectric-strength Relay
Compatible with Momentary
Voltage Drops
• No contact chattering for momentary voltage drops up to 50% of
rated voltage.
• Wide-range AC-activated coil that handles 100 to 120 or 200 to
240 VAC at either 50 or 60 Hz.
• Miniature size for maximum switching power, particularly for
inductive loads.
• Flame-resistance materials (UL94V-0-qualifying) used for all
insulation material.
• Quick-connect, screw, and PCB terminals, and DIN track
mounting available.
• Conforms to UL, CSA, TUV and meets IEC950.
• Safety design with contact gap of 3 mm.
Note. Accessories: E-bracket, Adapter, Front-connecting socket
and Cover sold separately.
RoHS Compliant
G
7
L
■Application Examples
■Model Number Legend
G7L-@@-@@@
x Compressors for air conditioners
and heater switching controllers.
x Switching controllers for power tools
or motors.
x Power controllers for water heaters.
x Power controllers for dryers.
x Lamp controls, motor drivers, and
power supply switching in copy
machines, facsimile machines, and
other office equipment.
— — — — —
1 2 3 4 5
1. Number of Poles 3. Terminal Shape
1: 1 pole
2: 2 poles
4. Mounting Construction
Blank: E-bracket
UB : Upper bracket
T: Quick connect
terminals (#250)
B: Screw terminals
P: PCB terminals
2. Contact Form
A: @PST-NO
5. Special Functions
J
: With test button
■Model Configuration
x Lighting controllers.
x Power controllers for packers or
Terminal
Quick-connect
terminals
Screw terminals
PCB terminals
food processing equipment.
x Magnetron control in microwaves.
x Power controllers for Uninterruptible
Power Supply (UPS)
Classification
Contact form
SPST-NO G7L-1A-T
DPST-NO G7L-2A-T
SPST-NO G7L-1A-TJ
DPST-NO G7L-2A-TJ
SPST-NO G7L-1A-TUB
DPST-NO G7L-2A-TUB
SPST-NO G7L-1A-TUBJ
DPST-NO G7L-2A-TUBJ
G7L-1A-B
G7L-2A-B
−
−
−
−
−
−
−
−
E-bracket
mounting
(E-bracket is
sold separately)
−
G7L-1A-BJ
G7L-2A-BJ
G7L-1A-BUB
G7L-2A-BUB
G7L-1A-BUBJ
G7L-2A-BUBJ
With test
button
−
Upper bracket
mounting
With test
button
SPST-NO
DPST-NO
−
−
−
−
G7L-1A-P
G7L-2A-P
PCB mounting
−
■List of E-bracket Mounting Models
Mounting E-brackets
DIN Track
Mounting
Adapter
Front-connecting
Socket
Contact
Terminal
form
Model
Test button
G7L-1A-T
−
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
{
−
−
−
SPST-NO
Quick-
connect
terminals
G7L-1A-TJ With test button
G7L-2A-T
G7L-2A-TJ With test button
G7L-1A-B
G7L-1A-BJ With test button
G7L-2A-B
G7L-2A-BJ With test button
−
DPST-NO
SPST-NO
DPST-NO
−
Screw
terminals
Note. Accessories: E-bracket (R99-07), Adapter (P7LF-D),
Front-connecting socket (P7LF-06) and Cover
(P7LF-C) sold separately.
−
−
1
G7L
Power Relay
■Ordering Information
E-bracket/Adapter/Socket Mounting
Quick-connect Terminal
E-bracket/Adapter/Socket Mounting (with test button)
Quick-connect Terminal
Number
of poles
Minimum
packing unit
Number
of poles
Minimum
packing unit
Model
Rated coil voltage
Model
Rated coil voltage
AC: 12, 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 24, 100/120, 200/240
DC: 12, 24, 48, 100
1 pole
G7L-1A-T
G7L-2A-T
1 pole
G7L-1A-TJ
G7L-2A-TJ
20 pcs./tray
20 pcs./tray
AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
2 poles
2 poles
Upper Bracket Mounting
Quick-connect Terminal
Upper Bracket Mounting (with test button)
Quick-connect Terminal
Number
Model
Minimum
packing unit
Number
of poles
Minimum
packing unit
Rated coil voltage
Model
Rated coil voltage
of poles
AC: 12, 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
1 pole
G7L-1A-TUB
G7L-2A-TUB
1 pole G7L-1A-TUBJ
2 poles G7L-2A-TUBJ
20 pcs./tray
20 pcs./tray
AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
2 poles
E-bracket/Adapter Mounting
Screw Terminal
E-bracket/Adapter Mounting (with test button)
Screw Terminal
Number
of poles
Minimum
packing unit
Number
of poles
Minimum
packing unit
Model
Rated coil voltage
Model
Rated coil voltage
AC: 12, 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 12, 24, 100/120, 200/240
DC: 12, 24
1 pole
G7L-1A-B
G7L-2A-B
1 pole
G7L-1A-BJ
G7L-2A-BJ
20 pcs./tray
20 pcs./tray
G
7
AC: 12, 24, 100/120, 200/240
DC: 12, 24, 48, 100
AC: 24, 100/120, 200/240
DC: 12, 24, 48, 100
2 poles
2 poles
L
Upper Bracket Mounting
Screw Terminal
Upper Bracket Mounting (with test button)
Screw Terminal
Number
Model
Minimum
packing unit
Number
of poles
Minimum
packing unit
Rated coil voltage
Model
Rated coil voltage
of poles
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48
1 pole
G7L-1A-BUB
1 pole G7L-1A-BUBJ
2 poles G7L-2A-BUBJ
20 pcs./tray
20 pcs./tray
AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
2 poles G7L-2A-BUB
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G7L-1A-T AC12
PCB Mounting
Number
Model
Minimum
packing unit
Rated coil voltage
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
Rated coil voltage
of poles
AC: 100/120, 200/240
DC: 12, 24, 48, 100
1 pole
G7L-1A-P
G7L-2A-P
Note 2. Refer to the precautions on PCB Relays provided in General
Information of the Relay Product Data Book, and "w -@-3" for coil
characteristics of AC operation.
20 pcs./tray
AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
2 poles
E-bracket/Adaptor/Socket/Cover
DIN Track Mounting Accessories
Applicable Relay
models
Minimum
packing unit
Name
Model
Minimum
packing unit
Applicable products
Name
Model
G7L-1A-T
G7L-1A-TJ
G7L-1A-B
G7L-1A-BJ
G7L-2A-T
G7L-2A-TJ
G7L-2A-B
G7L-2A-BJ
PFP-100N
PFP-50N
PFP-100N2
PFP-M
E-bracket
R99-07
10 pcs.
1 pcs.
1 pcs.
DIN Track
Adaptor Surface
Connection Socket
10 pcs.
End plate
Spacer
Adapter
P7LF-D
PFP-S
Note. Order the models above in increments of the minimum quantity packaged.
G7L-1A-T
G7L-1A-TJ
G7L-2A-T
G7L-2A-TJ
Front-connecting
Socket
P7LF-06
G7L-1A-B
G7L-1A-BJ
G7L-1A-BUB
G7L-1A-BUBJ
G7L-2A-B
Cover
P7LF-C
1 pcs.
G7L-2A-BJ
G7L-2A-BUB
G7L-2A-BUBJ
Note. Order the models above in increments of the minimum quantity packaged.
2
G7L
Power Relay
■Characteristics
■Ratings
Coil
Contact resistance *1
Operate time *2
Release time *3
50 mΩ max.
30 ms max.
30 ms max.
Item
Max.
permissible
voltage
Must operate Must release
voltage voltage
Coil inductance (H)
Rated
current
(mA)
Coil
Power
consumption
(VA-W)
resistance
Max.
operating
frequency
Mechanical
Rated load
1,800 operations/hr
1,800 operations/hr
(Ω)
Armature
ON
Armature
OFF
On the basis of rated voltage
Rated voltage
12 VAC
142
71
34
Insulation resistance *3
1,000 MΩ min
24 VAC
50 VAC
100 to 120 VAC 17.0 to 20.4
200 to 240 VAC
6 VDC
12 VDC
24 VDC
48 VDC
100 VDC
75% max.
15% min.
110%
Between coil and 4,000 VAC min., 50/60 Hz
contacts
Approx. 1.7
to 2.5
for 1 min
75 V max.
150 V max.
18 V min.
36 V min.
132 V
264 V
Between contacts
Dielectric
strength
of same polarity
8.5 to 10.2
2,000 VAC, 50/60 Hz for
1 min
Between contacts
of different polarity
(DPST-NO model)
317
158
79
40
19
18.9
75
303
1220
5260
0.09
0.37
1.42
6.1
0.21
0.88
3.54
15.3
60.0
75% max.
15% min.
110%
Approx. 1.9
10,000 V between coil and
contact *4
Impulse withstand voltage
21.3
10 to 55 to 10 Hz, 0.75 mm
Destruction
Vibration
single amplitude
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of
+15%/-20% for AC rated current and ±15% for DC coil resistance.
(1.5 mm double amplitude)
resistance
10 to 55 to 10 Hz, 0.75 mm
2. The inductances shown above are reference values.
Malfunction
single amplitude
3. Performance characteristic data are measured at a coil temperature of 23°C.
4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power
voltage, measured at ambient temperature 23°C.
(1.5 mm double amplitude)
Destruction
Shock
1,000 m/s2
100 m/s2
resistance
Malfunction
5. The "to" (for example "100 to 120") represents the range of rated voltages.
1,000,000 operations min.
(at 1,800 operations/hr)
100,000 operations min.
(at 1,800 operations/hr
under rated load)
Mechanical
Contacts
Endurance
Contact Form
G7L-1A-T@
G7L-1A-B@
G7L-2A-T@
G7L-2A-B@
G7L-1A-P
G7L-2A-P
Electrical *5
Inductive
Inductive
Failure rate (P level)
(reference value *6)
load
Resistive
load
Inductive load
Resistive
load
Resistive
load
100 mA at 5 VDC
load
load
(cosφ = 0.4)
G
7
L
(cosφ = 0.4)
(cosφ = 0.4)
Approx. 90 g:
Item
Contact type
Quick-connect terminal
models
Double break
Ag alloy
25 A at 220 VAC
25 A
Contact material
Rated load
Rated carry current
Weight
Approx. 100 g:
PCB terminal models
Approx. 120 g:
30 A at 220 VAC 25 A at 220 VAC
30 A
20 A at 220 VAC
20 A
Screw terminal models
Max. switching
voltage
Max. switching
current
250 VAC
25 A
Note. The values given above are initial values.
*1.
Measurement conditions: 5 VDC, 1 A, voltage drop
method.
30 A
20 A
*2.
Measurement conditions: Rated operating voltage applied,
not including contact bounce.
Note. When using B-series (screw) products, since the screw diameter of the contact terminal is M4, be careful
that the contact current should be 20 A or less according to JET standard (electrical appliance and material
control law of Japan).
Ambient temperature: 23°C
*3.
Measurement conditions: The insulation resistance was
measured with a 500-VDC megohmmeter at the same
locations as the dielectric strength was measured.
*4.
*5.
*6.
JEC-212 (1981) Standard Impulse Wave Type (1.2×50
Ambient temperature: 23°C
This value was measured at a switching frequency of 60
operations/min.
μs).
-25°C to 60°C
Ambient operating temperature (with no icing or
condensation)
Ambient operating humidity
5% to 85%
■Engineering Data
G7L-1A-T (TJ) (TUB) (TUBJ)
G7L-1A-B (BJ) (BUB) (BUBJ)
G7L-2A-T (TJ) (TUB) (TUBJ)
G7L-2A-B (BJ) (BUB) (BUBJ)
G7L-1A-P
Ambient Temperature vs. Operate
and Release Voltage
G7L-2A-P
Maximum Switching Power
Maximum Switching Power
Maximum Switching Power
G7L-1A VAC (60 Hz)
100
100
50
100
Operate voltage
AC resistive load
AC inductive load
(cosφ = 0.4)
Release voltage
AC resistive load
30
20
AC inductive load
(cosφ = 0.4)
50
AC resistive load
50
80
30
20
30
20
AC inductive load
(cosφ = 0.4)
60
40
10
10
10
7
5
7
5
7
5
3
3
3
20
0
1
1
1
10
50 70 100
300 500 1,000
Switching voltage (V)
10
50 70 100
300 500 1,000
10
50 70 100
300 500
-40
-20
0
20
40
60
80
30
30
30
Ambient temperature (°C)
Switching voltage (V)
Ambient temperature (°C)
Endurance
Endurance
Endurance
G7L-1A VDC
500
500
500
100
Operate voltage
Release voltage
300
300
300
80
60
40
100
100
100
220 VAC resistive load
220 VAC resistive load
70
50
70
50
70
50
220 VAC resistive load
30
30
30
220 VAC
inductive load
(cosφ = 0.4)
220 VAC
inductive load
(cosφ = 0.4)
220 VAC
inductive load
(cosφ = 0.4)
20
0
10
10
10
7
5
7
5
7
5
0
5
10
15
20
25
30
0
5
10
15
20
25
30
0
5
10
15
20
25
30
-40
-20
0
20
40
60
80
Switching current (A)
Switching current (A)
Switching current (A)
Ambient temperature (°C)
3
G7L
Power Relay
Ambient Temperature vs.
Coil Temperature Rise
G7L-1A 120 VAC (50 Hz)
Shock Malfunction
G7L-2A-T (TUB) 100 to 120 VAC
G7L-1A VDC
80
80
Y
N = 5
500
N=5
N=5
30 A
15 A
0 A
30 A
Test method: The value at which
15 A
0 A
malfunction occurred
was measured after
applying shock to the
test piece 3 times
each in 6 directions
along 3 axes.
400
300
200
100
60
40
60
40
Z'
X
2
Standard:
100m/s
100
100
200
300
200
X
X'
300
20
0
20
0
Y
400
X'
Z
Z
500
Z'
400
500
Unit: (m/s2
)
Y'
-40
-20
0
20
40
60
80
-40
-20
0
20
40
60
80
Shock direction
Y'
Ambient temperature (°C)
Ambient temperature (°C)
Momentary Voltage Drop Test
G7L-2A-T (TUB) 100 to 120 VAC
Test Circuit
Voltage distribution of wave e which
chattering does not occur.
Wave resulted from test
8
n=10
ON
Without chattering
Ch1
6
4
2
(contact)
OFF
Rated
voltage
Ch2
(coil)
Ch1
e
Ch2
G
7
L
0
20
40
60
80
100
On the basis of rated voltage (%)
Characteristic variation resulted from different mounting directions
G7L-2A-T (TUB) 100 to 120 VAC
Operate time
Release time
Operate voltage
Release voltage
25
35
80
50
N = 5
N = 5
N = 5
N = 5
20
30
70
40
Operate time
Release time
25
Operate voltage
60
15
10
5
30
Release voltage
20
50
40
20
15
10
0
0
0
0
A
A'
B
B'
C
C'
A
A'
B
B'
C
C'
A
A'
B
B'
C
C'
A
A'
B
B'
C
C'
Top
Top
Top
Top
Bottom(Standard)
(Note)
Bottom(Standard)
(Note)
Bottom(Standard)
(Note)
Bottom(Standard)
(Note)
Mounting direction
Mounting direction
Mounting direction
Mounting direction
(Note.)The mounting direction A’ deteriorates switching performance.
Actual Load Endurance Test
G7L-2A 100 to 200 VAC
Operate and Release voltages
Operate and Release voltages
N = 5
Contact resistance
N = 5
70
Contact resistance
70
100
50
Operate
voltage
N = 5
N = 5
N = 5
N = 5
60
60
Operate voltage
80
60
40
30
50
40
50
40
30
20
30
20
40
20
0
20
10
0
Release voltage
Release
voltage
10
0
10
0
0.50.7
1
3
5
7
10
30 50
0.50.7
1
3
5
7
10
30 50
0.050.070.1
0.3 0.5
1
3
5
0.050.070.1
0.3 0.5
1
3
5
Switching operations (×104 operations)
Switching operations (×104 operations)
Switching operations (×104 operations)
Switching operations (×104 operations)
Load conditions
• 1 φ 220 VAC
70 A cosφ = 0.4
Load conditions
• 1 φ 220 VAC
54 A cosφ = 0.79
(Compressor Lock Test)
20 A cosφ = 0.4
0.2s
1s
•
Applied coil voltage: 100% of rated
voltage
•
Applied coil voltage: 100% of rated
voltage
0.5s
10s
1s
4
G7L
Power Relay
G7L-2A 100 to 200 VAC
Operate and Release voltages
N = 5
Operate and Release voltages
N = 5
Contact resistance
Contact resistance
70
50
70
50
N = 5
N = 5
N = 5
N = 5
Operate voltage
60
Operate voltage
60
40
30
20
40
50
40
50
40
30
20
Release voltage
Release voltage
30
30
20
20
10
0
10
0
10
0
10
0
0.50.7
1
3
5
10
30 50
0.50.7
1
3
5
10
30 50
0.50.7
1
3
5
10
30 50
0.50.7
1
3
5
10
30 50
Switching operations (×102 operations)
Switching operations (×102 operations)
Switching operations (×102 operations)
Switching operations (×102 operations)
Load conditions
Load conditions
• 1 φ 220 VAC
• 1 φ 220 VAC
70 A cosφ = 0.4
20 A cosφ = 0.4
25 A cosφ = 1
0.2s
2s
•
Applied coil voltage: 75% of rated
voltage
•
Applied coil voltage: 75% of rated
voltage
2s
8s
8s
■Dimensions
● E-bracket Mounting
Quick-connect Terminals
Note. E-brackets are sold separately.
G
7
L
Terminal Arrangement/
Internal Connections
(Top View)
G7L-1A-T
52.5 max.
33.5 max.
0.8
50.5 max.
6.35
11
0
1
53 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-T
52.5 max.
50.5 max.
33.5 max.
0.8
6.35
6.35
6.35
11
0
2
1
8
4
6
53 max.
Mounting Holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
Two, 4.5-dia. hole or
M4 tapped holes
G7L-1A-TJ
52.5 max.
50.5 max.
33.5 max.
0.8
(with Test Button)
2
40 0.1
11
Test
button
0
1
4
6
53 max.
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-TJ
52.5 max.
50.5 max.
(with Test Button)
33.5 max.
0.8
2
11
Test
button
0
2
1
8
4
6
53 max.
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
5
G7L
● Adapter Mounting
Power Relay
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.
Quick-connect Terminals
Terminal Arrangement/
Internal Connections
(Top View)
G7L-1A-T
P7LF-D
PFP-@N
G7L
0
1
51.5 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
63 max.
5
66.5 max.
G7L-2A-T
P7LF-D
PFP-@N
G7L
0
2
1
8
51.5 max.
4
6
Mounting Holes
Two, M4 or 4.5-dia.
holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
63 max.
55.5 max.
5
66.5 max.
40 0.1
G7L-1A-TJ
(with Test Button)
P7LF-D
G
7
L
PFP-@N
G7L
0
1
51.5 max.
4
6
2
Test button
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
63 max.
55.5 max.
5
66.5 max.
G7L-2A-TJ
(with Test Button)
P7LF-D
PFP-@N
G7L
0
2
1
8
51.5 max.
4
6
2
Test button
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
63 max.
5
66.5 max.
● Front-connecting Socket Mounting
Quick-connect Terminals
Note 1. The Front-connecting Socket and DIN tracks are sold separately.
2. The Front-connecting Socket can be track-mounted or screw-mounted.
Terminal Arrangement/
Internal Connections
(Top View)
G7L-1A-T
P7LF-06
PFP-@N
2-M3.5 × 6 (coil side)
G7L
0
1
51.5 max.
4
6
Mounting Holes
Two, M4 or 4.5-dia.
holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
4-M4 × 8 (contact side)
61.5 max.
5
65 max.
40 0.1
P7LF-06
G7L-2A-T
PFP-@N
2-M3.5 × 6 (coil side)
G7L
0
2
1
8
51.5 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
4-M4 × 8 (contact side)
61.5 max.
65 max.
5
6
G7L
Power Relay
Terminal Arrangement/
Internal Connections
(Top View)
G7L-1A-TJ
(with Test Button)
P7LF-06
PFP-@N
2-M3.5 × 6 (coil side)
G7L
0
1
51.5 max.
4
6
Mounting Holes
2
Test button
Two, M4 or 4.5-dia.
holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
61.5 max.
65 max.
5
4-M4 × 8 (contact side)
40 0.1
G7L-2A-TJ
(with Test Button)
P7LF-06
PFP-@N
2-M3.5 × 6 (coil side)
G7L
0
2
1
8
51.5 max.
4
6
2
Test button
61.5 max.
65 max.
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
5
4-M4 × 8 (contact side)
● Upper Bracket Mounting
Quick-connect Terminals
G
7
L
G7L-1A-TUB
68.5 max.
60
Terminal Arrangement/
Internal Connections
(Top View)
50.5 max.
33.5 max.
6.35
6.35
6.35
0.8
11
0
1
47 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
G7L-2A-TUB
68.5 max.
60
50.5 max.
33.5 max.
0.8
11
0
2
1
8
47 max.
Mounting Holes
4
6
Two, 4.5-dia. hole or
M4 tapped holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
2.5
4.5
G7L-1A-TUBJ
(with Test Button)
68.5 max.
60
50.5 max.
33.5 max.
60 0.2
2
0.8
11
Test
button
0
1
47 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
2.5
4.5
G7L-2A-TUBJ
(with Test Button)
68.5 max.
60
50.5 max.
33.5 max.
0.8
2
6.35
Test
button
11
0
2
1
8
47 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
2.5
4.5
7
G7L
● E-bracket Mounting
Power Relay
Note. E-brackets are sold separately.
Screw Terminals
Terminal Arrangement/
Internal Connections
(Top View)
G7L-1A-B
52.5 max.
2-M3.5 × 6
(coil side)
2-M4 × 8
(contact side)
50.5 max.
34.5 max.
0
1
55 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-B
52.5 max.
50.5 max.
2-M3.5 × 6
(coil side)
4-M4 × 8
(contact side)
34.5 max.
0
2
1
8
55 max.
Mounting Holes
4
6
Two, 4.5-dia. hole or
M4 tapped holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-1A-BJ
(with Test Button)
52.5 max.
50.5 max.
2-M4 × 8
2
2-M3.5 × 6
(coil side)
34.5 max.
40 0.1
(contact side)
G
7
L
Test
button
0
1
55 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-BJ
52.5 max.
50.5 max.
(with Test Button)
4-M4 × 8
(contact side)
2-M3.5 × 6
(coil side)
2
34.5 max.
Test
button
0
2
1
8
55 max.
4
6
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
● Adapter Mounting
Screw Terminals
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.
G7L-1A-B
G7L-2A-B
8
Terminal Arrangement/
Internal Connections
(Top View)
P7LF-D
PFP-@N
2-M3.5 × 6 (coil side)
G7L
0
1
51.5 max.
4
6
Mounting Holes
55.5 max.
2-M4 × 8 (contact side)
65.5 max.
69 max.
5
Two, M4 or 4.5-dia.
holes
(No coil polarity)
Note. Refer to page 12 for the coil
internal connection diagram
40 0.1
P7LF-D
PFP-@N
2-M3.5 × 6 (coil side)
G7L
0
2
1
8
51.5 max.
4
6
55.5 max.
4-M4 × 8 (contact side)
65.5 max.
69 max.
(No coil polarity)
Note. Refer to page 12 for the coil
internal connection diagram
5
G7L
Power Relay
G7L-1A-BJ
(with Test Button)
Terminal Arrangement/
Internal Connections
(Top View)
P7LF-D
PFP-@N
2-M3.5 × 6 (coil side)
G7L
0
1
51.5 max.
4
6
Mounting Holes
2
Test button
Two, M4 or 4.5-dia.
holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
65.5 max.
5
69 max.
2-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
40 0.1
G7L-2A-BJ
(with Test Button)
P7LF-D
PFP-@N
G7L
0
2
1
8
51.5 max.
4
6
2
Test button
65.5 max.
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
55.5 max.
5
69 max.
4-M4 × 8 (contact side)
● Upper Bracket Mounting
Screw Terminals
G
7
L
G7L-1A-BUB
68.5 max.
60
2-M3.5 × 6
(coil side)
Terminal Arrangement/
Internal Connections
(Top View)
2-M4 × 8
(contact side)
50.5 max.
34.5 max.
0
1
49 max.
4
6
2.5
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
G7L-2A-BUB
68.5 max.
60
2-M3.5 × 6
(coil side)
4-M4 × 8
(contact side)
50.5 max.
34.5 max.
0
2
1
8
49 max.
Mounting Holes
4
6
Two, 4.5-dia. hole or
M4 tapped holes
2.5
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
G7L-1A-BUBJ
(with Test Button)
68.5 max.
60
2-M3.5 × 6
(coil side)
60 0.2
2-M4 × 8
2
50.5 max.
34.5 max.
(contact side)
Test
button
0
1
49 max.
4
6
2.5
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
G7L-2A-BUBJ
(with Test Button)
68.5 max.
60
2-M3.5 × 6
(coil side)
4-M4 × 8
(contact side)
50.5 max.
34.5 max.
2
Test
button
0
2
1
8
49 max.
4
6
2.5
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4.5
9
G7L
● PCB Mounting
Power Relay
PCB Terminals
G7L-1A-P
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
35.5 max.
0.8
52.5 max.
2.8
6
36.8
3.2
0
1
47 max.
(8.4)
41 max.
4
6
14.4
1.2
17.7
(8.9)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
4-1.2 × 3.2 square hole
G7L-2A-P
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
52.5 max.
35.5 max.
0.8
2.8
6
36.8
3.2
0
2
1
8
47 max.
(8.4)
41 max.
4
6
14.4
1.2
17.7
(8.9)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
6-1.2 × 3.2 square hole
40
46
● E-bracket
R99-07 (E KANAGU)
FOR G7L
Two, 4.5-dia. hole
Mounting Holes
Two, M4 or 4.5-dia.
holes
26
24 17.8
G
7
L
40
10
3
24
19.7
7
5
30
50
5
4.4
● Adapter
P7LF-D
Mounting Holes
Two, M4 or 4.5-dia.
holes
51.5 max.
40 0.1
40 0.1
14.5
5
35.2 max.
55.5 max.
2-M3.5 × 6 (coil side)
8
0.05
● Front-connecting
Socket
Mounting Holes
P7LF-06
Two, M4 or 4.5-dia.
holes
51.5 max.
40 0.1
25
9.2 0.05
4-M4 × 8
(contact side)
5
46 max.
40 0.1
55.5 max.
● Cover
P7LF-C
34.5 max.
Put the P7LF-C cover onto the terminals in order to protect the
user from electric shock.
1
50.5 max.
6 max.
10
G7L
Power Relay
Approved Standards
x A variety of Safety Standard approved products for standard models.
UL Recognized (File No. E41643)
EN/IEC, TÜV Certified
(Certificate No. R50059083)
Number of test
operations
Approved
switching
operations
Model
Coil ratings
Contact ratings
Model
G7L-1A-B
G7L-2A-B
Coil ratings
Contact ratings
30 A, 277 VAC (RES) 40°C
1.5 kW, 120 VAC (T) 40°C
1.5 HP, 120 VAC 40°C
100,000
6,000
1,000
G7L-1A-T
G7L-1A-B
G7L-1A-P
G7L-2A-T
G7L-2A-B
G7L-2A-P
@
SPST-NO (1a)
@
30 A, 250 VAC ~ (cos
φ
= 1) 60°C
= 0.4) 60°C
= 0.4) 60°C
@
@
50,000
50,000
12 to 240 VAC
6 to 220 VDC
25 A, 250 VAC ~ (cos
φ
φ
3 HP 277 VAC 40°C
100,000
@
@
30 A, 120 VAC ~ (cos
20 FLA/120 LRA, 120 VAC 40°C
17 FLA/102 LRA, 277 VAC 40°C
TV-10, 120 VAC 40°C
30,000
25,000
DPST-NO (2a)
25 A, 277 VAC ~ (cos
φ
= 1) 60°C
= 0.4) 60°C
25 A, 277 VAC ~ (cos
φ
SPST-NO (1a)
25 A, 240 VAC ~ (cos
25 A, 240 VAC ~ (cos
25 A, 277 VAC ~ (cos
25 A, 277 VAC ~ (cos
DPST-NO (2a)
25 A, 240 VAC ~ (cos
25 A, 240 VAC ~ (cos
25 A, 277 VAC ~ (cos
25 A, 277 VAC ~ (cos
SPST-NO (1a)
20 A, 240 VAC ~ (cos
20 A, 240 VAC ~ (cos
25 A, 277 VAC ~ (cos
25 A, 277 VAC ~ (cos
DPST-NO (2a)
20 A, 240 VAC ~ (cos
20 A, 240 VAC ~ (cos
25 A, 277 VAC ~ (cos
25 A, 277 VAC ~ (cos
CSA certified
(File No. LR31928)
φ
= 1) 60°C
= 0.4) 60°C
= 1) 60°C
= 0.4) 60°C
Number of test
operations
G7L-1A-T
G7L-2A-T
@
@
50,000
50,000
50,000
50,000
φ
Model
Coil ratings
Contact ratings
φ
φ
6, 12, 24, 48,
100, 110, 200,
220 VDC
12, 24, 50,
100 to 120,
200 to 240
VAC
2.4 kW, 120 VAC (T) 40°C
1.5 HP, 120 VAC (T) 40°C
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C
TV-10, 120 VAC 40°C
30 A, 277 VAC (RES) 40°C
2.4 kW, 120 VAC (T) 40°C
1.5 HP, 120 VAC 40°C
6,000
1,000
12 to 240 VAC
6 to 220 VDC
G7L-1A-P
φ
= 1) 60°C
= 0.4) 60°C
= 1) 60°C
φ = 0.4) 60°C
100,000
25,000
100,000
6,000
φ
φ
G7L-1A-T
G7L-1A-B
@
@
φ
= 1) 60°C
= 0.4) 60°C
= 1) 60°C
= 0.4) 60°C
12 to 240 VAC
6 to 220 VDC
1,000
G7L-1A-P
G7L-2A-P
φ
G7L-2A-T
G7L-2A-B
G7L-2A-P
@
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C
TV-10, 120 VAC 40°C
φ
@
100,000
25,000
φ
G
7
L
●Reference
φ
= 1) 60°C
= 0.4) 60°C
= 1) 60°C
= 0.4) 60°C
UL Approved Type ....................................................
UL508 Industrial Control Devices
UL1950 Information processing equipment
(Including office equipment)
φ
φ
φ
CSA Approved Type ..................................................
CSA C22.2 No.1, 14
Industrial Control Devices
CSA C22.2 No.950 Information processing equipment
(Including office equipment)
TÜV EN/IEC Standard Approved Type......................
EN61810-1 Relay
EN60950 Information processing equipment
(Including office equipment)
IEC950 Information processing equipment
(Including office equipment)
11
G7L
Power Relay
■Precautions
● Please refer to “PCB Relays Common Precautions” for general precautions.
Correct Use
● Installation
● Connecting
When connecting with screws, if the
screws are not sufficiently tightened,
the lead wire can become detached
and may lead to abnormal heating or
fire caused by faulty contact.
• Although there are not specific limits
on the installation site, it should be as
dry and dust-free as possible.
• Using in an atmosphere of high
temperature, high humidity and
corrosive gas may deteriorate its
performance characteristic caused by
condensation or corrosive products,
resulting in failure or burn damage of
the Relay.
• Refer to the following table when
connecting a wire with a crimpstyle
terminal to the G7L.
Front-connecting
Screw terminals
• Mounting Torque
Socket
.
0.98N
m
8
8
Tighten with two M4 screws when
mounting.
(Top bracket type)
• Do not apply excessive force when
mounting or dismounting the Faston
receptacle.Insert and remove
terminals carefully one at a time. Do
not insert terminals at an angle, or
insert/remove multiple terminals at the
same time.
• Do not connect to the terminals by
soldering
• Refer to the following table for
recommendations of connectors
made by OMRON.
5.8
5
6.5
5.3
Coil
M3.5
M4
M3.5
M4
• PCB Terminal-equipped Relays weigh
approximately 100 g.
5.5
6.5
5.5
7
Be sure that the PCB is strong enough
to support them. We recommend
dual-side through-hole PCBs to
reduce solder cracking from heat
stress.
• Relays with test buttons must be
mounted facing down.
Be careful not to touch the test button
accidentally. Doing so may turn ON
the contact.
Contact
9.2
9.2
• Allow suitable slack on leads when
wiring, and do not apply excessive
force to the terminals.
• Tightening torque
G
7
L
.
.
Coil:
0.78 to 1.18 N
m
m
Contact: 0.98 to 1.37 N
• Be sure to use the test button for test
purposes only (with test-button
models). The test button is used for
Relay circuit tests, such as circuit
continuity tests. Do not attempt to
switch the load with the test button.
Type
Receptacle terminals
Housing
XT3W-S441-12
XT3W-S442-12
XT3W-S443-12
#250 terminals
(width: 6.35 mm)
XT3B-1S white
Note. The current should be 25 A when using receptacle terminals.
● Micro Loads
• The G7L is used for switching power
loads, such as motor, transformer,
solenoid, lamp, and heater loads. Do
not use the G7L for switching micro
loads, such as signals.
● Reference Data
● DIN Track Mounting Adapter and
Front-connecting Socket
• The ratio of rated voltage between 100
to 120 VAC are values measured on
the basis of 100 VAC.
(DIN Track Mounting)
• The DIN Track Mounting Adapter and
Front-connecting Socket can be
mounted on the G7L with just one
hand and dismounted with ease by
using a screwdriver.
● Soldering PCB Terminals
● Operating Coil
• Do not perform automatic soldering
but solder manually.
• Solder with the following conditions:
Soldering iron temperature (max.)
380°C, Soldering time within 10
seconds.
• Do not wash down the entire Relay
because it does not have an airtight
construction.
(Coil internal connections diagram)
• DC Coil
• To support the G7L mounted on a DIN
Track Mounting Adapter or
0
1
Front-connecting Socket, use the
PFP-M End Plate. Put the End Plate
onto the DIN Track Mounting Adapter
or Front-connecting Socket so that the
surface mark of the End Plate faces
upwards. Then tighten the screw of the
End Plate securely with a screwdriver.
• AC Coil
0
1
(Screw Mounting)
• If a transistor drives the G7L check the
leakage current, and connect a
bleeder resistor if necessary.
• The AC coil is provided with a built-in
full-wave rectifier. If a triac, such as an
SSR, drives the G7L, the G7L may not
release. Be sure to perform a trial
operation with the G7L and the triac
before applying them to actual use.
• Screw-mount the DIN Track Mounting
Adapter or Front-connecting Socket
securely after opening screw mounting
holes on them.
• When cutting or opening holes on the
panel after the Front-connecting
Socket is mounted, take proper
measures so that the cutting chips will
not fall onto the Relay terminals. When
cutting or opening holes on the upper
part of the panel, mask the
Front-connecting Socket properly with
a cover.
12
G7L
Power Relay
G
7
L
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J055-E1-14
1116(0207)(O)
13
相关型号:
©2020 ICPDF网 联系我们和版权申明