General Purpose Relay  
G7L  
• Ideally suited for high-inrush fluid pump controls: pool/spa, water  
processing, emergency, chemical industry, etc.  
• High-capacity, high-withstand voltage relay with no contact chatter-  
ing for momentary voltage drops up to 50% of rated voltage.  
• UL Class B construction standard.  
• Wide-range AC-activated coil that handles 100 to 120 VAC at either  
50 or 60 Hz.  
• Miniature hinge for maximum switching capacity, particularly for in-  
ductive loads.  
• Flame resistant materials (UL94V-0-qualifying) used for  
all insulation material.  
• Quick-connect, screw, and PCB terminals available.  
• Standard models are UL, CSA, and TUV approved;  
VDE/IEC 950 versions are now available. Meet pollution degree 3,  
Material Group II & III.  
Ordering Information  
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).  
Type  
Contact form  
Model  
Quick-connect terminal  
G7L-1A-T-CB  
G7L-2A-T-CB  
G7L-1A-TJ-CB  
G7L-2A-TJ-CB  
G7L-1A-TUB-CB  
G7L-2A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-2A-TUBJ-CB  
Screw terminal  
PCB terminal  
E bracket (see note 1)  
SPST-NO  
G7L-1A-B-CB  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
G7L-2A-B-CB  
G7L-1A-BJ-CB  
G7L-2A-BJ-CB  
G7L-1A-BUB-CB  
G7L-2A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-2A-BUBJ-CB  
E bracket (see note 1)  
(with test button)  
Upper bracket  
Upper bracket  
(with test button)  
PCB mounting  
G7L-1A-P-CB  
G7L-2A-P-CB  
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and part numbers.  
2. For VDE approved versions, please consult OMRON.  
3. CE marking is provided only on non-PCB terminal versions.  
General Purpose Relay G7L  
329  
Model Number Legend  
G7L- ❏ ❏ - ❏ ❏ ❏ ❏  
1 2 3 4 5  
6
1. Contact form  
1A:SPST-NO  
3. Mounting construction  
No symbol:E bracket type  
UB:Upper bracket type  
5. 80: VDE approved version  
(includes UL, CSA and TÜV)  
2A:DPST-NO  
6. CB: Class B insulation  
7. Rated coil voltage  
2. Terminal shape  
4. Special functions  
No symbol:Without test button  
J:With test button  
T:Quick-connect terminals  
P:PCB terminals  
B:Screw terminals  
Accessories  
Quick-connect Terminals  
Description  
Model  
Model  
Contact form  
SPST-NO  
G7L-1A-TJ  
DPST-NO  
G7L-2A-TJ  
E-brackets  
Track mounting adaptor  
Front connecting socket  
G7L-1A-T  
G7L-2A-T  
R99-07G5D  
P7LF-D  
P7LF-06  
Note: A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.  
Screw Terminals  
Description  
Model  
Model  
Contact form  
SPST-NO  
G7L-1A-BJ  
DPST-NO  
G7L-2A-BJ  
E-brackets  
G7L-1A-B  
G7L-2A-B  
R99-07G5D  
Track mounting adaptor  
Terminal Cover  
P7LF-D  
P7LF-C  
Note: The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.  
Specifications  
Contact Data  
Load  
G7L-1A-T, G7L-1A-B  
G7L-2A-T, G7L-2A-B  
Resistive load Inductive load  
(cosφ = 1) (cosφ = 0.4)  
G7L-1A-P, G7L-2A-P  
Resistive load  
Inductive load  
(cosφ = 0.4)  
25 A, 220 VAC  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4)  
(cosφ = 1)  
30 A, 220 VAC  
AgSnIn  
Rated load  
Contact material  
Carry current  
20 A, 220 VAC  
30 A  
25 A  
25 A  
20 A  
Max. operating voltage 250 VAC  
Max. operating current 30 A  
Max. switching capacity 6,600 VA  
20 A  
5,500 VA  
4,400 VA  
Min. permissible load  
100 mA, 5 VDC (please inquire for lower minimum rating)  
Note: P level: λ60 = 0.1 x 10-6 operation.  
Coil Internal Circuit  
DC operating coil  
AC operating coil  
330  
General Purpose Relay G7L  
Coil Data  
AC  
Rated voltage  
(V)  
Rated current  
(mA)  
Resistance  
Must operate  
75% max.  
Must release  
% of rated voltage  
15% min.  
Max. voltage  
110% max.  
Power  
(Ω)  
consumption  
6
283  
142  
18.90  
Approx.1.70  
to 2.50 VA  
12  
75  
24  
71  
303  
50  
34  
1,310  
5,260  
21,000  
100/120  
200/240  
17.00/20.40  
8.50/10.20  
75 volts  
18 volts  
36 volts  
132 volts  
264 volts  
150 volts  
DC  
Rated voltage  
(V)  
Rated current  
(mA)  
Resistance  
(Ω)  
Must operate  
75% max.  
Must release  
% of rated voltage  
15% min.  
Max. voltage  
110% max.  
Power  
consumption  
6
317  
158  
79  
18.90  
75  
Approx.1.90 W  
12  
24  
48  
100  
303  
40  
1,220  
5,260  
19  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for AC rated cur-  
rent and 15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C (73°F).  
Characteristics  
Contact resistance  
50 mΩ max.  
Operate time  
30 ms max.  
Release time  
30 ms max.  
Max. operating  
frequency  
Mechanical  
Electrical  
1,800 operations/hour  
1,800 operations/hour (under rated load)  
Insulation resistance  
Dielectric strength  
1,000 MΩ min. (at 500 VDC)  
4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts  
2,000 VAC, 50/60 Hz for 1 minute between contacts of same pole  
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (DPST-NO type)  
Between coil and contact: 10,000 V min./12,000 V typ. (impulse wave used: 1.20 x 50 μs)  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
Impulse withstand voltage  
Vibration  
Mechanical  
durability  
Malfunction  
durability  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
1,000 m/s2 (approx. 100 G)  
Shock  
Mechanical  
durability  
1,000 m/s2 (approx.10 G)  
Malfunction  
durability  
Life expectancy  
Mechanical  
Electrical  
1,000,000 operations min. (at 1,800 operations/hour)  
100,000 operations min. (at 1,800 operations/hour under rated load 250,000 ops typical)  
-25° to 60°C (-13° to 140°F)  
Ambient temperature  
Humidity  
35% to 85% RH  
Weight  
Quick-connect terminal type: approx. 90 g (3.17 oz)  
PCB terminal type: approx. 100 g (3.52 oz)  
Screw terminal type: approx. 120 g (4.23 oz)  
Note: Data shown are of initial value.  
General Purpose Relay G7L  
331  
Characteristic Data  
Maximum switching capacity  
Electrical service life  
Switching current (A)  
Switching voltage (V)  
Dimensions  
Unit: mm (inch)  
Relays  
G7L-1A-T  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-T  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
332  
General Purpose Relay G7L  
G7L-1A-TJ  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TJ  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-TUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
*E bracket must be ordered separately.  
General Purpose Relay G7L  
333  
Unit: mm (inch)  
G7L-1A-TUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-B  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-B  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
334  
General Purpose Relay G7L  
G7L-1A-BJ  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BJ  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-BUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
General Purpose Relay G7L  
335  
Unit: mm (inch)  
G7L-1A-BUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BUBJ  
Mounting holes  
(Bottom view)  
Terminal arrangement/  
Internal connections  
(Top view)  
G7L-1A-P  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-P  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
336  
General Purpose Relay G7L  
Accessories  
E bracket  
R99-07G5D  
Mounting holes  
(Bottom view)  
Adaptor  
P7LF-D  
Mounting holes  
(Bottom view)  
Front connecting socket  
P7LF-06  
Mounting holes  
(Bottom view)  
Note: 1. To protect against electric shock, a socket terminal cover is supplied with the P7LF-06 socket.  
2. The P7LF-06 is panel or track mountable.  
General Purpose Relay G7L  
337  
Unit: mm (inch)  
Cover  
P7LF-C  
Note: P7LF-C cover attaches directly to G7L-B style relays. To protect against electric shock, use the P7LF-C on G7L-B terminals.  
Mounting track  
PFP-100N, PFP-50N  
(Conforming to EN 50022)  
PFP-100N2  
(Conforming to EN 50022)  
16  
7.3 0.15  
35 0.3  
4.5  
4.5  
27  
35 0.3  
29.2  
1.5  
24  
27 0.15  
1
15 25  
25  
25  
25 15  
15 25  
25  
25  
25  
*
1
15 (5)  
10  
10  
10  
10  
1000  
4
1000 (500)*  
* The figure in parenthesis is for PFP-50N.  
Note: 1. It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used.  
2. L = Length  
PFP-100N L = 1 m (39.00 in)  
PFP-50N  
L = 50 cm (19.60 in)  
PFP-100N2 L = 1 m (39.00 in)  
End plate  
PFP-M  
Spacer  
PFP-S  
338  
General Purpose Relay G7L  
Approvals  
UL Recognized (File No. E41643) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40°C  
Type  
G7L-1A-T-CB  
G7L-1A-TJ-CB  
G7L-1A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-1A-B-CB  
G7L-1A-BJ-CB  
G7L-1A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-1A-P-CB  
Contact form  
Terminal type  
Contact ratings  
30 A, 277 VAC, General Use, 100,000 ops  
1.5 kW, 120 VAC, Tungsten, 6,000 ops  
1.5 HP, 120 VAC, 6,000 ops  
SPST-NO  
Quick-connect  
3 HP, 277 VAC, 6,000 ops  
20 FLA/120 LRA, 120 VAC, 30,000 ops  
17 FLA/102 LRA, 265 VAC, 30,000 ops  
TV-10, 120 VAC, 25,000 ops  
Screw  
PCB  
G7L-2A-T-CB  
DPST-NO  
Quick-connect  
G7L-2A-TJ-CB  
G7L-2A-TUB-CB  
G7L-2A-TUBJ-CB  
G7L-2A-B-CB  
G7L-2A-BJ-CB  
G7L-2A-BUB-CB  
G7L-2A-BUBJ-CB  
G7L-2A-P-CB  
Screw  
PCB  
Note: Contact Omron for actual ratings marked on G7L relays  
TÜV (File No. R9251551)  
Type  
Contact form  
Coil ratings  
Terminal type  
Contact ratings  
G7L-1A-T-CB  
G7L-1A-TJ-CB  
G7L-1A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-1A-B-CB  
G7L-1A-BJ-CB  
G7L-1A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-1A-P-CB  
SPST-NO  
6, 12, 24, 48,  
100, 110, 200,  
220 VDC  
Quick-connect  
25 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
12, 24, 50,  
100/120, 200/240  
VAC  
Screw  
30 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
30 A, 240 VAC, (cosφ = 0.4)  
PCB  
20 A, 240 VAC, (cosφ = 1)  
20 A, 240 VAC, (cosφ = 0.4)  
25 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
G7L-2A-T-CB  
DPST-NO  
Quick-connect  
G7L-2A-TJ-CB  
G7L-2A-TUB-CB  
G7L-2A-TUBJ-CB  
G7L-2A-B-CB  
G7L-2A-BJ-CB  
G7L-2A-BUB-CB  
G7L-2A-BUBJ-CB  
G7L-2A-P-CB  
Screw  
PCB  
25 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
20 A, 240 VAC, (cosφ = 1)  
20 A, 240 VAC, (cosφ = 0.4)  
VDE recognized type (Licence no. 1530 UG)  
Note: 1. Please consult OMRON for details of VDE approvals.  
2. The G7L relay conforms to the following standards:  
Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83  
DIN VDE 0435 Teil 201 A1/05. 90  
DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81  
DIN EN 60 950/VDE 0805/11. 93  
EMC:  
prEN 50082-2, EN 55022  
3. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics  
individually defined in this catalog.  
4. In the interest of product improvement, specifications are subject to change.  
5. Suffix T130 rated at 130°C  
6. Pollution degree 3, Material Group II & III.  
7. CE marking is provide only on non-PCB terminal versions.  
General Purpose Relay G7L  
339  
Precautions  
Handling  
Operating Coil  
To preserve initial performance, do not drop or otherwise subject  
As a rule, either a battery or a DC power supply with a maximum  
5% ripple is used for the operating voltage for DC relays. Before  
using a rectified AC supply, confirm that the ripple is not greater  
than 5%. Ripple greater than this can lead to variations in the oper-  
ating and reset voltages.  
the power relay to shock.  
The case is not designed to be removed during normal handling  
and operation. Doing so may affect performance.  
Use the power relay in a dry environment free from excessive dust,  
SO2, H2S, or organic gas.  
As excessive ripple can generate beats, the insertion of a  
smoothing capacitor is recommended as shown below.  
Do not allow a voltage greater than the maximum allowable coil  
voltage to be applied continuously.  
Do not use the power relay outside of specified voltages and cur-  
rents.  
Do not allow the ambient operating temperature to exceed the  
specified limit.  
Installation  
Although there are not specific limits on the installation site, it  
should be as dry and dust-free as possible.  
PCB terminal-equipped relays weigh approximately 100 g. Be sure  
that the PCB is strong enough to support them. We recommend  
dual-side through-hole PCBs to reduce solder cracking from heat  
stress.  
Quick-connect terminals can be connected to fast on receptacle  
#250 and positive-lock connectors.  
Allow suitable slack on leads when wiring, and do not subject the  
terminals to excessive force.  
When driving a transistor, check the leakage current and connect a  
bleeder resistor if necessary.  
Cleaning PCB Terminals  
PCB terminals have semi-sealed construction which prevents flux  
from entering the relay base. It is recommended that the user  
should apply a tape seal over the vent hole prior to wave soldering  
or cleaning. The tape should then be removed after processing.  
Momentary voltage drops on coil input voltage should not exceed  
one second duration after contact mating with no shock or vibra-  
tion.  
Applications  
Compressors for package air conditioners and heater switching  
controllers  
Switching controllers for power tools or motors  
Power controllers for water heaters  
Power controllers for dryers  
Lamp control, motor drivers, and power supply switching in copy  
machines, facsimiles, and other OA equipment  
Lighting controllers  
Power controllers for packers or food processing equipment  
Magnetron control in microwaves  
340  
General Purpose Relay G7L  
MEMO  
General Purpose Relay G7L  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
09/11  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1b  
General Purpose Relay G7L  

相关型号:

G7L-2A-B-CB-AC24

Power/Signal Relay, DPST, Momentary, 2500mW (Coil), AC Input, AC Output, Panel Mount
OMRON

G7L-2A-B-CB-AC50

Power/Signal Relay, DPST, Momentary, 2500mW (Coil), AC Input, AC Output, Panel Mount
OMRON

G7L-2A-B-CB-AC6

Power/Signal Relay, DPST, Momentary, 2500mW (Coil), AC Input, AC Output, Panel Mount,
OMRON

G7L-2A-B-CB-DC100

Power/Signal Relay, DPST, Momentary, 0.019A (Coil), 100VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-B-CB-DC12

Power/Signal Relay, DPST, Momentary, 0.16A (Coil), 12VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-B-CB-DC24

Power/Signal Relay, DPST, Momentary, 0.079A (Coil), 24VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-B-CB-DC6

Power/Signal Relay, DPST, Momentary, 0.317A (Coil), 6VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON