G7SB-2A2BDC24 [OMRON]

Power/Signal Relay, 4PST, Momentary, 0.015A (Coil), 24VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount;
G7SB-2A2BDC24
型号: G7SB-2A2BDC24
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, 4PST, Momentary, 0.015A (Coil), 24VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount

继电器
文件: 总5页 (文件大小:281K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
GRela7ysSwithBForcibly Guided Contacts  
CSM_G7SB_DS_E_3_1  
Low Profile Relays with Low Power  
Consumption  
• Relays with forcibly guided contacts  
(EN50205 Class A, certified by VDE).  
• Low profile - only 14.5 mm.  
• Coil power consumption is 360 mW for 4 pole model or  
500 mW for 6 pole model.  
• Four-pole and six-pole Relays are available.  
• The Relay's terminal arrangement simplifies PWB pattern  
design.  
• Reinforced insulation.  
Be sure to read the “Safety Precautions” on page 4 and the  
“Precautions for All Relays with Forcibly Guided Contacts”.  
Model Number Structure  
Model Number Legend  
G7SB-@A@B  
1
2
1. NO Contact Poles  
2: DPST-NO  
2. NC Contact Poles  
1: SPST-NC  
3: 3PST-NO  
2: DPST-NC  
4: 4PST-NO  
5: 5PST-NO  
Ordering Information  
Relays with Forcibly Guided Contacts  
Type  
Sealing  
Poles  
Contact configuration  
3PST-NO, SPST-NC  
DPST-NO, DPST-NC  
5PST-NO, SPST-NC  
4PST-NO, DPST-NC  
Rated voltage *  
Model  
G7SB-3A1B  
G7SB-2A2B  
G7SB-5A1B  
G7SB-4A2B  
4 poles  
Standard  
Flux-tight  
24 VDC  
6 poles  
* Consult your OMRON representative for details on rated voltages of 12 VDC, 18 VDC and 21 VDC.  
1
G7SB  
Specifications  
Ratings  
Coil  
Item  
Rated current  
(mA)  
Coil resistance Mustoperate Must release  
Max.  
voltage (V)  
Power consumption  
Rated voltage  
(Ω)  
voltage (V)  
voltage (V)  
(mW)  
4 poles: 15  
6 poles: 20.8  
4 poles: 1,600  
6 poles: 1,152  
4 poles: Approx. 360  
6 poles: Approx. 500  
24 VDC  
75% max.  
10% min.  
110%  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.  
2. Performance characteristics are based on a coil temperature of 23°C.  
3. The value given for the maximum voltage is for voltages applied Instantaneously to the Relay coil (at an ambient temperature of 23°C)  
and not continuously.  
Contacts  
Item  
Load  
Resistive load  
Rated load  
6 A at 250 VAC, 6 A at 30 VDC  
Rated carry current  
Max. switching voltage  
Max. switching current  
6 A  
250 VAC, 125 VDC  
6 A  
Characteristics  
Contact resistance *1  
Operating time *2  
Response time *3  
Release time *2  
100 mΩ max.  
20 ms max.  
10 ms max.  
20 ms max.  
Mechanical  
36,000 operations/h  
Maximum operating  
frequency  
Rated load  
1,800 operations/h  
Insulation resistance *4  
Dielectric strength *5  
Vibration resistance  
1,000 MΩ min. (at 500 VDC)  
Between coil contacts/different poles: 3,000 VAC, 50/60 Hz for 1 min.  
Between poles 12, 23, and 34: 3,000 VAC, 50/60 Hz for 1 min.  
Between poles 45 and 56 (in 6-pole relays): 2,500 VAC, 50/60 Hz for 1 min.  
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min.  
10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
1,000 m/s2  
100 m/s2  
Destruction  
Shock resistance  
Malfunction  
Mechanical  
Electrical  
10,000,000 operations min. (at approx. 36,000 operations/h)  
100,000 operations min. (at the rated load and approx. 1,800 operations/h)  
Durability *6  
Failure rate (P level)  
(reference value *7)  
5 VDC, 1 mA  
Ambient operating temperature *8 40 to 85°C (with no icing or condensation)  
Ambient operating humidity  
5% to 85%  
4 poles: Approx. 25 g  
6 poles: Approx. 29 g  
Weight  
Note: The above values are initial values.  
*1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.  
*2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.  
*3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF. Contact bounce time is  
included. Measurement conditions: Rated voltage operation, Ambient temperature: 23°C  
*4. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured.  
*5. Pole 3 refers to terminals 3334, pole 4 refers to terminals 4344, pole 5 refers to terminals 5354, and pole 6 refers to terminals  
6364.  
*6. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.  
*7. The failure rate is based on an operating frequency of 300 operations/min.  
*8. When operating at a temperature between 70 and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree above 70°C.  
2
G7SB  
Dimensions  
(Unit: mm)  
Relays with Forcibly Guided Contacts  
Terminal Arrangement/  
Internal Connection Diagram  
(Bottom View)  
G7SB-3A1B  
G7SB-2A2B  
25.5 max.  
45.0 max.  
G7SB-3A1B  
11  
23  
33  
43  
14.5 max.  
3.50  
0.50  
0.50  
0.50  
1
1
0.50  
1
1
+
Printed Circuit Board  
Design Diagram  
12  
24  
34  
33  
44  
43  
(Bottom View)  
( 0.1 tolerance)  
G7SB-2A2B  
Ten, 1.4 dia.  
11  
21  
20.32  
(1.73)  
15.40  
18  
(2.10)  
7.62 7.62 7.62  
+
12  
22  
34  
44  
Note: Terminals 23-24, 33-34, and 43-44 are  
normally open. Terminals 11-12 and 21-22  
are normally closed.  
G7SB-5A1B  
G7SB-4A2B  
Terminal Arrangement/  
Internal Connection Diagram  
(Bottom View)  
25.5 max.  
55.1 max.  
G7SB-5A1B  
11  
23  
33  
43 53 63  
14.5 max.  
0.50  
0.50  
0.50  
1
1
0.50  
1
3.50  
1
+
Printed Circuit Board  
Design Diagram  
12  
11  
24  
34  
44 54 64  
(Bottom View)  
( 0.1 tolerance)  
G7SB-4A2B  
Fourteen, 1.4 dia.  
21  
33  
43 53 63  
20.32  
(1.73)  
15.40  
18  
(2.10)  
7.62 7.62 7.62 5.08 5.08  
+
12  
22  
34  
44 54 64  
Note: Terminals 23-24, 33-34, 43-44, 53-54, and  
63-64 are normally open. Terminals 11-12 and  
21-22 are normally closed.  
Certified Standards  
Forcibly Guided Contacts (from EN50205)  
G7SB  
If an NO contact becomes welded, all NC contacts will maintain a  
minimum distance of 0.5 mm when the coil is not energized. Likewise  
if an NC contact becomes welded, all NO contacts will maintain a  
minimum distance of 0.5 mm when the coil is energized.  
EN Standards, VDE Certified  
EN61810-1 (Electromechanical non-specified time all-or-nothing  
relays)  
EN50205 (Relays with forcibly guided (linked) contacts)  
UL standard UL508 Industrial Control Devices  
CSA standard CSA C22.2 No. 14 Industrial Control Devices  
3
G7SB  
Safety Precautions  
Refer to the “Precautions for All Relays” and “Precautions for All Relays with Forcibly Guided Contacts”.  
Precautions for Safe Use  
Connections  
The coil terminals have polarity (+/). Operation will not be possible if  
the polarity is reversed.  
Washing  
The G7SB does not have a sealed structure. Do not wash G7SB  
Relays.  
4
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.12  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

G7SB-3A1B

Power/Signal Relay
OMRON

G7SB-3A1BDC24

Power/Signal Relay, 4PST, Momentary, 0.015A (Coil), 24VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON

G7SB-4A2B

Power/Signal Relay
OMRON

G7SB-4A2BDC24

Power/Signal Relay, 6PST, Momentary, 0.021A (Coil), 24VDC (Coil), 500mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON

G7SB-5A1B

Power/Signal Relay
OMRON

G7SB-5A1BDC24

Power/Signal Relay, 6PST, Momentary, 0.021A (Coil), 24VDC (Coil), 500mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON

G7T-1012S

Power/Signal Relay
OMRON

G7T-1112S

Power/Signal Relay
OMRON

G7T-1122S

Power/Signal Relay
OMRON

G7T-112S

Power/Signal Relay
OMRON
OMRON

G7TC-IA16AC220/240V

Analog Circuit
OMRON