GRela7ysSwithBForcibly Guided Contacts
CSM_G7SB_DS_E_3_1
Low Profile Relays with Low Power
Consumption
• Relays with forcibly guided contacts
(EN50205 Class A, certified by VDE).
• Low profile - only 14.5 mm.
• Coil power consumption is 360 mW for 4 pole model or
500 mW for 6 pole model.
• Four-pole and six-pole Relays are available.
• The Relay's terminal arrangement simplifies PWB pattern
design.
• Reinforced insulation.
Be sure to read the “Safety Precautions” on page 4 and the
“Precautions for All Relays with Forcibly Guided Contacts”.
Model Number Structure
Model Number Legend
G7SB-@A@B
1
2
1. NO Contact Poles
2: DPST-NO
2. NC Contact Poles
1: SPST-NC
3: 3PST-NO
2: DPST-NC
4: 4PST-NO
5: 5PST-NO
Ordering Information
Relays with Forcibly Guided Contacts
Type
Sealing
Poles
Contact configuration
3PST-NO, SPST-NC
DPST-NO, DPST-NC
5PST-NO, SPST-NC
4PST-NO, DPST-NC
Rated voltage *
Model
G7SB-3A1B
G7SB-2A2B
G7SB-5A1B
G7SB-4A2B
4 poles
Standard
Flux-tight
24 VDC
6 poles
* Consult your OMRON representative for details on rated voltages of 12 VDC, 18 VDC and 21 VDC.
1
G7SB
Specifications
Ratings
Coil
Item
Rated current
(mA)
Coil resistance Mustoperate Must release
Max.
voltage (V)
Power consumption
Rated voltage
(Ω)
voltage (V)
voltage (V)
(mW)
4 poles: 15
6 poles: 20.8
4 poles: 1,600
6 poles: 1,152
4 poles: Approx. 360
6 poles: Approx. 500
24 VDC
75% max.
10% min.
110%
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
2. Performance characteristics are based on a coil temperature of 23°C.
3. The value given for the maximum voltage is for voltages applied Instantaneously to the Relay coil (at an ambient temperature of 23°C)
and not continuously.
Contacts
Item
Load
Resistive load
Rated load
6 A at 250 VAC, 6 A at 30 VDC
Rated carry current
Max. switching voltage
Max. switching current
6 A
250 VAC, 125 VDC
6 A
Characteristics
Contact resistance *1
Operating time *2
Response time *3
Release time *2
100 mΩ max.
20 ms max.
10 ms max.
20 ms max.
Mechanical
36,000 operations/h
Maximum operating
frequency
Rated load
1,800 operations/h
Insulation resistance *4
Dielectric strength *5
Vibration resistance
1,000 MΩ min. (at 500 VDC)
Between coil contacts/different poles: 3,000 VAC, 50/60 Hz for 1 min.
Between poles 1−2, 2−3, and 3−4: 3,000 VAC, 50/60 Hz for 1 min.
Between poles 4−5 and 5−6 (in 6-pole relays): 2,500 VAC, 50/60 Hz for 1 min.
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min.
10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
1,000 m/s2
100 m/s2
Destruction
Shock resistance
Malfunction
Mechanical
Electrical
10,000,000 operations min. (at approx. 36,000 operations/h)
100,000 operations min. (at the rated load and approx. 1,800 operations/h)
Durability *6
Failure rate (P level)
(reference value *7)
5 VDC, 1 mA
Ambient operating temperature *8 −40 to 85°C (with no icing or condensation)
Ambient operating humidity
5% to 85%
4 poles: Approx. 25 g
6 poles: Approx. 29 g
Weight
Note: The above values are initial values.
*1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
*2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.
*3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF. Contact bounce time is
included. Measurement conditions: Rated voltage operation, Ambient temperature: 23°C
*4. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured.
*5. Pole 3 refers to terminals 33−34, pole 4 refers to terminals 43−44, pole 5 refers to terminals 53−54, and pole 6 refers to terminals
63−64.
*6. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
*7. The failure rate is based on an operating frequency of 300 operations/min.
*8. When operating at a temperature between 70 and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree above 70°C.
2
G7SB
Dimensions
(Unit: mm)
Relays with Forcibly Guided Contacts
Terminal Arrangement/
Internal Connection Diagram
(Bottom View)
G7SB-3A1B
G7SB-2A2B
25.5 max.
45.0 max.
G7SB-3A1B
11
23
33
43
14.5 max.
3.50
−
0.50
0.50
0.50
1
1
0.50
1
1
+
Printed Circuit Board
Design Diagram
12
24
34
33
44
43
(Bottom View)
( 0.1 tolerance)
G7SB-2A2B
Ten, 1.4 dia.
11
21
−
20.32
(1.73)
15.40
18
(2.10)
7.62 7.62 7.62
+
12
22
34
44
Note: Terminals 23-24, 33-34, and 43-44 are
normally open. Terminals 11-12 and 21-22
are normally closed.
G7SB-5A1B
G7SB-4A2B
Terminal Arrangement/
Internal Connection Diagram
(Bottom View)
25.5 max.
55.1 max.
G7SB-5A1B
11
23
33
43 53 63
14.5 max.
−
0.50
0.50
0.50
1
1
0.50
1
3.50
1
+
Printed Circuit Board
Design Diagram
12
11
24
34
44 54 64
(Bottom View)
( 0.1 tolerance)
G7SB-4A2B
Fourteen, 1.4 dia.
21
33
43 53 63
−
20.32
(1.73)
15.40
18
(2.10)
7.62 7.62 7.62 5.08 5.08
+
12
22
34
44 54 64
Note: Terminals 23-24, 33-34, 43-44, 53-54, and
63-64 are normally open. Terminals 11-12 and
21-22 are normally closed.
Certified Standards
Forcibly Guided Contacts (from EN50205)
G7SB
If an NO contact becomes welded, all NC contacts will maintain a
minimum distance of 0.5 mm when the coil is not energized. Likewise
if an NC contact becomes welded, all NO contacts will maintain a
minimum distance of 0.5 mm when the coil is energized.
• EN Standards, VDE Certified
EN61810-1 (Electromechanical non-specified time all-or-nothing
relays)
EN50205 (Relays with forcibly guided (linked) contacts)
• UL standard UL508 Industrial Control Devices
• CSA standard CSA C22.2 No. 14 Industrial Control Devices
3
G7SB
Safety Precautions
Refer to the “Precautions for All Relays” and “Precautions for All Relays with Forcibly Guided Contacts”.
Precautions for Safe Use
Connections
The coil terminals have polarity (+/−). Operation will not be possible if
the polarity is reversed.
Washing
The G7SB does not have a sealed structure. Do not wash G7SB
Relays.
4
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
·
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.12
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.
相关型号:
G7SB-3A1BDC24
Power/Signal Relay, 4PST, Momentary, 0.015A (Coil), 24VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON
G7SB-4A2BDC24
Power/Signal Relay, 6PST, Momentary, 0.021A (Coil), 24VDC (Coil), 500mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON
G7SB-5A1BDC24
Power/Signal Relay, 6PST, Momentary, 0.021A (Coil), 24VDC (Coil), 500mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON
©2020 ICPDF网 联系我们和版权申明