GX-F12A-P [OMRON]

Rectangular-shaped Inductive Proximity Sensor;
GX-F12A-P
型号: GX-F12A-P
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Rectangular-shaped Inductive Proximity Sensor

文件: 总16页 (文件大小:1582K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Amplifier Built-in  
Rectangular-shaped Inductive Proximity Sensor  
761  
GX-F/H SERIES  
General terms and conditions........... F-17  
Glossary of terms........................ P.1386~  
Sensor selection guide ................. P.757~  
General precautions ..................... P.1405  
FIBER  
SENSORS  
Related Information  
LASER  
SENSORS  
PHOTOELECTRIC  
SENSORS  
Conforming to  
EMC Directive  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
LIGHT  
CURTAINS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
panasonic-electric-works.net/sunx  
PNP output  
type available  
Oil resistant  
Different freq.  
type available  
STATIC CONTROL  
DEVICES  
ENDOSCOPE  
* Based on research conducted by Panasonic Electric Works SUNX  
as of August 2010 among equivalent rectangular inductive sensors.  
Industry No. 1* in stable sensing  
LASER  
MARKERS  
PLC /  
TERMINALS  
Can be installed with ample space  
HUMAN MACHINE  
INTERFACES  
This sensor has the longest stable sensing range among the same level of rectangular inductive proximity sensors in  
the industry. It is easy to install the sensor.  
ENERGY CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Stable sensing range  
Maximum  
operation  
distance  
Maximum operation distance  
Stable sensing range  
Type  
FA COMPONENTS  
GX-F/H  
Previous model  
series  
MACHINE VISION  
SYSTEMS  
1.6 mm 0.063 in  
2.5 mm 0.098 in  
4.0 mm 0.157 in  
5.0 mm 0.197 in  
8.0 mm 0.315 in  
0 to 1.3 mm 0.051 in  
0 to 2.1 mm 0.083 in  
0 to 3.3 mm 0.130 in  
0 to 4.2 mm 0.165 in  
0 to 6.7 mm 0.264 in  
0 to 1.2 mm 0.047 in  
0 to 1.8 mm 0.709 in  
0 to 3.0 mm 0.118 in  
0 to 4.0 mm 0.157 in  
0 to 6.4 mm 0.252 in  
GX-6  
GX-8  
GX-12  
GX-15  
GX-F/H  
series  
UV CURING  
SYSTEMS  
Previous  
model  
Long sensing  
range  
Selection  
Guide  
Amplifier  
Built-in  
Amplifier-  
separated  
* With standard sensing object  
Variation at the maximum operation distance is within ±8 %  
Temperature characteristics vary within ±8 %  
Thorough adjustment and control of sensing sensitivity  
greatly reduces individual sensor differences and  
variations.  
The work of adjusting sensor positions when using  
multiple sensors and when sensors have been replaced  
is much easier.  
Components such as the sensor coil and core and  
product design have been totally revised to provide  
excellent temperature characteristics.  
Stable sensing can be obtained regardless of the time of  
day or the yearly season.  
GX-F/H  
GXL  
GL  
GX-U/GX-FU/  
GX-N  
GX-F/H series  
Example: GX-8  
GX  
Previous models  
16.0  
0.4 mm 0.016 in or less  
14.0  
Sensing range within temperatures  
Operation distance variation: 0.4 mm 0.016 in or less*  
12.0  
of –25 to +70 °C  
10.0  
(–13 to +158 °F) are within  
8.0  
8 % of the range at +23 °C (+73 °F)  
For the  
6.0  
Previous models:  
23 °C  
73 °F  
GX-8  
(
+15  
)
Standard  
4.0  
2.0  
within  
%
–10  
sensing object  
Maximum operation distance: 2.5 mm 0.098 in 8 ꢀ  
60%  
0.0  
–2.0  
less  
(2.3 to 2.7 mm 0.091 to 0.106 in)  
–20 –10  
0
10 20 30 40 50 60 70  
1.0 mm 0.039 in or less  
Operation distance variation: 1.0 mm 0.039 in or less  
–4 14 32 50 68 86 104 122 140 158  
Ambient temperature [°C °F]  
Standard  
Previous  
model  
sensing  
object  
* Typical  
Maximum operation distance: 2.5 mm 0.098 in 20 ꢀ  
(2.0 to 3.0 mm 0.079 to 0.118 in)  
Image  
* Not including temperature characteristics.  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
762  
APPLICATIONS  
FIBER  
SENSORS  
LASER  
SENSORS  
Muting control of light curtains  
Positioning processing equipment  
Positioning metal pallets  
PHOTOELECTRIC  
SENSORS  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
LIGHT  
CURTAINS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
ENVIRONMENTAL RESISTANCE  
SENSOR  
OPTIONS  
10 times the durability! (Compared to previous models)  
SIMPLE  
WIRE-SAVING  
UNITS  
The new integrated construction method used provides shock resistance of 10,000 m/s2 (approx. 1,000 G in X, Y and Z directions  
for three times each), and vibration resistance clears durability tests of between 10 and 500 Hz (3 mm 0.118 in amplitude in X, Y  
and Z directions for 2 hours each). In addition, resistance to impulse noise is approx. three times greater than for previous models.  
WIRE-SAVING  
SYSTEMS  
Checking up / down  
operation of  
compact molding  
equipment  
Sensing presence of metallic  
objects on a part feeder  
MEASUREMENT  
SENSORS  
STATIC CONTROL  
DEVICES  
ENDOSCOPE  
LASER  
MARKERS  
Shock resistance:  
1,000 G  
PLC /  
TERMINALS  
Vibration resistance: 500 Hz  
HUMAN MACHINE  
INTERFACES  
FUNCTIONS  
Highly resistant to water or oil!  
IP68g* protective construction  
ENERGY CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Indicators are easy to see over a wide field of view  
The new integrated construction method used improves  
environmental resistance performance.  
The IP68g prevents damage to the sensor by stopping  
water and oil getting inside.  
A prism with a wide field of view has been developed. This  
has greatly improved the visibility of the operation indicators.  
GX-H  
FA COMPONENTS  
MACHINE VISION  
SYSTEMS  
* For details, refer to the “SPECIFICATIONS”.  
UV CURING  
SYSTEMS  
GX-F□  
Selection  
Guide  
Amplifier  
Built-in  
Amplifier-  
separated  
GX-F/H  
GXL  
MOUNTING  
GL  
Tightening strength increased with no damage! (excluding GX-□6)  
Conductor thickness doubled to make wiring much easier! (GX-□6/□8 only)  
GX-U/GX-FU/  
GX-N  
A metal sleeve has been inserted.  
It prevents the sensor from being damaged by tightening  
too much.  
The conductor’s thickness was doubled for the GX-□6/□8.  
This makes it easier to handle and perform crimping  
work on the cables. In addition, the tensile strength of the  
crimping area has become higher.  
GX  
GX-□8, GX-□12  
GX-□15  
0.08 mm2  
0.15 mm2  
Metal sleeve  
Previous model  
GX-□8  
Metal sleeve  
Approx. 1.4 times  
greater than before  
Conductor thickness approx.  
2 times greater  
M3 screw  
M3 screw  
Tightening torque: 0.7 N ∙ m or less Tightening torque: 1 N ∙ m or less  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
763  
FIBER  
ORDER GUIDE  
SENSORS  
LASER  
SENSORS  
GX-6 type  
PHOTO-  
ELECTRIC  
SENSORS  
Model No.  
(Note 2)  
Type  
Appearance (mm in)  
Sensing range (Note 1)  
Output  
Output operation  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
GX-F6A  
AREA  
GX-F6AI  
SENSORS  
6
0.236  
24.5  
GX-F6B  
LIGHT  
0.965  
6 0.236  
CURTAINS  
GX-F6BI  
NPN open-collector  
transistor  
PRESSURE /  
FLOW  
GX-H6A  
SENSORS  
GX-H6AI  
GX-H6B  
Maximum  
operation distance  
INDUCTIVE  
PROXIMITY  
SENSORS  
6
0.236  
25  
0.984  
1.6 mm 0.063 in  
PARTICULAR  
USE  
6
0.236  
GX-H6BI  
GX-F6A-P  
GX-F6AI-P  
GX-F6B-P  
GX-F6BI-P  
GX-H6A-P  
GX-H6AI-P  
GX-H6B-P  
GX-H6BI-P  
SENSORS  
(0 to 1.3 mm 0 to 0.051 in)  
SENSOR  
OPTIONS  
6
0.236  
0.236  
SIMPLE  
WIRE-SAVING  
UNITS  
Stable sensing range  
24.5  
0.965  
6
PNP open-collector  
transistor  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
SENSORS  
6
0.236  
0.236  
25  
0.984  
STATIC  
CONTROL  
DEVICES  
6
Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
ENDOSCOPE  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient  
temperature drift and/or supply voltage fluctuation.  
2) “ I ” in the model No. indicates a different frequency type.  
LASER  
MARKERS  
PLC /  
TERMINALS  
GX-8 type  
HUMAN  
MACHINE  
INTERFACES  
Model No.  
(Note 2)  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Type  
Appearance (mm in)  
Sensing range (Note 1)  
Output  
Output operation  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
GX-F8A  
FA  
COMPONENTS  
GX-F8AI  
7.4 0.291  
23  
MACHINE  
VISION  
GX-F8B  
SYSTEMS  
8 0.315  
0.906  
GX-F8BI  
UV  
CURING  
NPN open-collector  
transistor  
SYSTEMS  
GX-H8A  
GX-H8AI  
GX-H8B  
Maximum  
operation distance  
8.2 0.323  
8 0.315  
25  
0.984  
Selection  
Guide  
2.5 mm 0.098 in  
GX-H8BI  
GX-F8A-P  
GX-F8AI-P  
GX-F8B-P  
GX-F8BI-P  
GX-H8A-P  
GX-H8AI-P  
GX-H8B-P  
GX-H8BI-P  
Amplifier  
Built-in  
(0 to 2.1 mm 0 to 0.083 in)  
Amplifier-  
separated  
7.4 0.291  
8 0.315  
Stable sensing range  
23  
0.906  
GX-F/H  
GXL  
GL  
PNP open-collector  
transistor  
GX-U/GX-FU/  
GX-N  
8.2 0.323  
8 0.315  
25  
0.984  
GX  
Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient  
temperature drift and/or supply voltage fluctuation.  
2) “ I ” in the model No. indicates a different frequency type.  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
764  
ORDER GUIDE  
FIBER  
SENSORS  
LASER  
SENSORS  
GX-12 type  
PHOTO-  
ELECTRIC  
SENSORS  
Model No.  
(Note 2)  
Type  
Appearance (mm in)  
Sensing range (Note 1)  
Output  
Output operation  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
GX-F12A  
AREA  
GX-F12AI  
GX-F12B  
SENSORS  
7.1 0.280  
27.8  
LIGHT  
12  
1.094  
0.472  
CURTAINS  
GX-F12BI  
GX-H12A  
NPN open-collector  
transistor  
PRESSURE /  
FLOW  
SENSORS  
GX-H12AI  
GX-H12B  
INDUCTIVE  
PROXIMITY  
SENSORS  
12 0.472  
Maximum  
operation distance  
27.4  
1.079  
12 0.472  
PARTICULAR  
USE  
4.0 mm 0.157 in  
GX-H12BI  
GX-F12A-P  
GX-F12AI-P  
GX-F12B-P  
GX-F12BI-P  
GX-H12A-P  
GX-H12AI-P  
GX-H12B-P  
GX-H12BI-P  
SENSORS  
(0 to 3.3 mm 0 to 0.130 in)  
SENSOR  
OPTIONS  
7.1 0.280  
SIMPLE  
Stable sensing range  
WIRE-SAVING  
UNITS  
27.8  
1.094  
12  
0.472  
PNP open-collector  
transistor  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
12 0.472  
12 0.472  
SENSORS  
27.4  
1.079  
STATIC  
CONTROL  
DEVICES  
Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
ENDOSCOPE  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient  
temperature drift and/or supply voltage fluctuation.  
2) “ I ” in the model No. indicates a different frequency type.  
LASER  
MARKERS  
PLC /  
TERMINALS  
GX-15 type  
HUMAN  
MACHINE  
INTERFACES  
Model No.  
(Note 2)  
ENERGY  
Type  
Appearance (mm in)  
Sensing range (Note 1)  
Output  
Output operation  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
GX-F15A  
FA  
COMPONENTS  
GX-F15AI  
GX-F15B  
8 0.315  
0.591  
MACHINE  
VISION  
31.5  
SYSTEMS  
1.240  
15  
GX-F15BI  
GX-H15A  
UV  
NPN open-collector  
transistor  
CURING  
SYSTEMS  
16.5 0.650  
15 0.591  
GX-H15AI  
GX-H15B  
Maximum  
operation distance  
29.5  
1.161  
Selection  
Guide  
5.0 mm 0.197 in  
GX-H15BI  
GX-F15A-P  
GX-F15AI-P  
GX-F15B-P  
GX-F15BI-P  
GX-H15A-P  
GX-H15AI-P  
GX-H15B-P  
GX-H15BI-P  
Amplifier  
Built-in  
(0 to 4.2 mm 0 to 0.165 in)  
Amplifier-  
separated  
8 0.315  
Stable sensing range  
31.5  
GX-F/H  
GXL  
GL  
1.240  
0.591  
15  
PNP open-collector  
transistor  
16.5 0.650  
15 0.591  
GX-U/GX-FU/  
GX-N  
29.5  
1.161  
GX  
Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an  
ambient temperature drift and/or supply voltage fluctuation.  
2) “ I ” in the model No. indicates a different frequency type.  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
765  
FIBER  
ORDER GUIDE  
SENSORS  
LASER  
SENSORS  
GX-15 (Long sensing range) type  
PHOTO-  
ELECTRIC  
SENSORS  
Model No.  
(Note 2)  
Type  
Appearance (mm in)  
Sensing range (Note 1)  
Output  
Output operation  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
Normally open  
Normally closed  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
GX-FL15A  
AREA  
SENSORS  
GX-FL15AI  
GX-FL15B  
8 0.315  
0.591  
LIGHT  
31.5  
CURTAINS  
1.240  
15  
GX-FL15BI  
GX-HL15A  
NPN open-collector  
transistor  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
16.5 0.650  
15 0.591  
GX-HL15AI  
GX-HL15B  
Maximum  
operation distance  
29.5  
1.161  
PARTICULAR  
USE  
8.0 mm 0.315 in  
(0 to 6.7 mm 0 to 0.264 in)  
Stable sensing range  
GX-HL15BI  
GX-FL15A-P  
GX-FL15AI-P  
GX-FL15B-P  
GX-FL15BI-P  
GX-HL15A-P  
GX-HL15AI-P  
GX-HL15B-P  
GX-HL15BI-P  
SENSORS  
SENSOR  
OPTIONS  
8 0.315  
SIMPLE  
WIRE-SAVING  
UNITS  
31.5  
1.240  
0.591  
15  
WIRE-SAVING  
SYSTEMS  
PNP open-collector  
transistor  
MEASURE-  
MENT  
16.5 0.650  
15 0.591  
SENSORS  
STATIC  
CONTROL  
DEVICES  
29.5  
1.161  
ENDOSCOPE  
Notes: 1) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an  
ambient temperature drift and/or supply voltage fluctuation.  
2) “ I ” in the model No. indicates a different frequency type.  
LASER  
MARKERS  
PLC /  
TERMINALS  
5 m 16.404 ft cable length type, flexible cable type  
HUMAN  
MACHINE  
5 m 16.404 ft cable length type (standard: 1 m 3.281 ft) and flexible cable (excluding 5 m 16.404 ft cable length type) are available.  
However, long sensing range type is not available. When ordering 5 m 16.404 ft cable length type, suffix “-C5” to the model No. When  
ordering flexible cable type, suffix “-R” to the model No.  
INTERFACES  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
(e.g.) 5 m 16.404 ft cable length type of GX-F15AI-P is “GX-F15AI-P-C5”. Flexible cable type of GX-F15AI-P is “GX-F15AI-P-R”.  
FA  
COMPONENTS  
OPTIONS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
Designation  
Model No.  
Description  
SYSTEMS  
Mounting bracket for GX-6 type (recommended).  
Sensors can be mounted closely together for space-saving.  
MS-GX6-1  
Selection  
Guide  
Sensor  
mounting  
bracket  
Mounting brackets for GX-6 type  
Sensor mounting brackets for GL-6 can be used. Interchange is  
possible.  
MS-GL6-1  
MS-GL6-2  
MS-GXL8-4  
MS-GXL15  
MS-A15F  
Amplifier  
Built-in  
Amplifier-  
separated  
Mounting bracket for GX-8 type  
Mounting bracket for GX-15 type  
GX-F/H  
GXL  
GL  
Mounting example when  
mounted onto a steel or  
stainless steel plate  
For GX-FL15□(-P)  
For GX-HL15□(-P)  
Aluminum  
sheet  
MS-A15H  
GX-U/GX-FU/  
GX-N  
Sensor mounting bracket  
· MS-GX6-1  
Aluminum sheet  
GX  
· MS-GXL8-4  
· MS-GXL15  
· MS-A15F  
· MS-A15H  
Nut is not  
attached.  
1pc. each of M3  
Nut is not  
attached.  
(length: 12 mm 0.472 in)  
truss head screw, nut,  
spring washer and plain  
washer is attached.  
· MS-GL6-1  
· MS-GL6-2  
Nut is not  
attached.  
Nut is not  
attached.  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
766  
SPECIFICATIONS  
FIBER  
SENSORS  
LASER  
SENSORS  
GX-6 type  
PHOTO-  
ELECTRIC  
SENSORS  
Type  
Front sensing  
Top sensing  
NPN output  
PNP output  
MICRO  
GX-F6A(I)  
GX-H6A(I)  
GX-F6B(I)  
GX-H6B(I)  
GX-F6A(I)-P  
GX-H6A(I)-P  
GX-F6B(I)-P  
GX-H6B(I)-P  
PHOTO-  
ELECTRIC  
SENSORS  
Item  
AREA  
SENSORS  
Max. operation distance (Note 3)  
Stable sensing range (Note 3)  
Standard sensing object  
Hysteresis  
1.6 mm 0.063 in ± 8 %  
0 to 1.3 mm 0 to 0.051 in  
LIGHT  
CURTAINS  
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in  
PRESSURE /  
FLOW  
20 % or less of operation distance (with standard sensing object)  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Repeatability  
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less  
+10  
–15  
Supply voltage  
12 to 24 V DC  
Ripple P-P 10 % or less  
%
PARTICULAR  
USE  
Current consumption  
15 mA or less  
SENSORS  
SENSOR  
OPTIONS  
NPN open-collector transistor  
PNP open-collector transistor  
• Maximum source current: 100 mA  
• Maximum sink current: 100 mA  
Output  
SIMPLE  
• Applied voltage: 30 V DC or less (between output and 0 V)  
• Residual voltage: 2 V or less (at 100 mA sink current)  
• Applied voltage: 30 V DC or less (between output and +V)  
• Residual voltage: 2 V or less (at 100 mA source current)  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
Utilization category  
Output operation  
Max. response frequency  
Operation indicator  
Pollution degree  
DC-12 or DC-13  
400 Hz  
Normally closed  
Normally closed  
Normally closed  
Normally closed  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Orange LED (lights up when the output is ON)  
3 (Industrial environment)  
ENDOSCOPE  
Protection  
IP68 (IEC), IP68g (JEM) (Note 4, 5)  
LASER  
Ambient temperature  
Ambient humidity  
EMC  
–25 to +70 °C –13 to +158 °F, Storage: – 40 to +85 °C – 40 to +185 °F  
35 to 85 % RH, Storage: 35 to 95 % RH  
EN 60947-5-2  
MARKERS  
PLC /  
TERMINALS  
HUMAN  
MACHINE  
INTERFACES  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure  
10 to 500 Hz frequency, 3 mm 0.118 in amplitude (Max. 20 G) in X, Y and Z directions for two hours each  
10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions for three times each  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
FA  
COMPONENTS  
Sensing  
range  
variation  
Temperature characteristics  
Voltage characteristics  
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ± 8 % of sensing range at +23 °C +73 °F  
+10  
MACHINE  
VISION  
SYSTEMS  
Within ±2 % for  
% fluctuation of the supply voltage  
–15  
UV  
CURING  
SYSTEMS  
Material  
Cable  
Enclosure: PBT, Indicator part: Polyester  
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long  
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.  
15 g approx.  
Cable extension  
Net weight  
Selection  
Guide  
Amplifier  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73 °F.  
2) “ I ” in the model No. indicates a different frequency type.  
Built-in  
Amplifier-  
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient  
temperature drift and/or supply voltage fluctuation.  
separated  
GX-F/H  
GXL  
GL  
4) Panasonic Electric Works SUNX’s IP68 test method  
1
2
3
4
Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m below +70 °C +158 °F water surface and leave for 30 min.  
1
Regard the heat shock test in  
as one cycle and perform 20 cycles.  
Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.  
GX-U/GX-FU/  
GX-N  
1
3
to , insulation resistance, voltage withstandability, current consumption, and sensing range must meet the standard values.  
After tests  
5) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.  
GX  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
767  
FIBER  
SPECIFICATIONS  
SENSORS  
LASER  
SENSORS  
GX-8 type  
PHOTO-  
ELECTRIC  
SENSORS  
Type  
Front sensing  
Top sensing  
NPN output  
PNP output  
MICRO  
PHOTO-  
GX-F8A(I)  
GX-H8A(I)  
GX-F8B(I)  
GX-H8B(I)  
GX-F8A(I)-P  
GX-H8A(I)-P  
GX-F8B(I)-P  
GX-H8B(I)-P  
ELECTRIC  
SENSORS  
Item  
AREA  
SENSORS  
Max. operation distance (Note 3)  
Stable sensing range (Note 3)  
Standard sensing object  
Hysteresis  
2.5 mm 0.098 in ± 8 %  
0 to 2.1 mm 0 to 0.083 in  
LIGHT  
CURTAINS  
Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in  
PRESSURE /  
FLOW  
20 % or less of operation distance (with standard sensing object)  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Repeatability  
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less  
+10  
–15  
Supply voltage  
12 to 24 V DC  
Ripple P-P 10 % or less  
%
PARTICULAR  
USE  
Current consumption  
15 mA or less  
SENSORS  
SENSOR  
OPTIONS  
NPN open-collector transistor  
PNP open-collector transistor  
• Maximum source current: 100 mA  
• Maximum sink current: 100 mA  
• Applied voltage: 30 V DC or less (between output and 0 V)  
• Residual voltage: 2 V or less (at 100 mA sink current)  
Output  
SIMPLE  
WIRE-SAVING  
UNITS  
• Applied voltage: 30 V DC or less (between output and +V)  
• Residual voltage: 2 V or less (at 100 mA source current)  
WIRE-SAVING  
SYSTEMS  
Utilization category  
Output operation  
Max. response frequency  
Operation indicator  
Pollution degree  
DC-12 or DC-13  
MEASURE-  
MENT  
Normally open  
Normally closed  
Normally open  
Normally closed  
SENSORS  
500 Hz  
STATIC  
CONTROL  
DEVICES  
Orange LED (lights up when the output is ON)  
3 (Industrial environment)  
ENDOSCOPE  
Protection  
IP68 (IEC), IP68g (JEM) (Note 4, 5)  
LASER  
Ambient temperature  
Ambient humidity  
EMC  
–25 to +70 °C –13 to +158 °F, Storage: – 40 to +85 °C – 40 to +185 °F  
35 to 85 % RH, Storage: 35 to 95 % RH  
EN 60947-5-2  
MARKERS  
PLC /  
TERMINALS  
HUMAN  
MACHINE  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure  
10 to 500 Hz frequency, 3 mm 0.118 in amplitude (Max. 20 G) in X, Y and Z directions for two hours each  
10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions for three times each  
INTERFACES  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
FA  
COMPONENTS  
Sensing  
range  
variation  
MACHINE  
VISION  
Temperature characteristics  
Voltage characteristics  
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ± 8 % of sensing range at +23 °C +73 °F  
+10  
SYSTEMS  
Within ±2 % for  
% fluctuation of the supply voltage  
–15  
UV  
CURING  
Material  
Cable  
Enclosure: PBT, Indicator part: Polyester  
SYSTEMS  
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long  
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.  
Front sensing type: 15 g approx., Top sensing type: 20 g approx..  
Cable extension  
Net weight  
Selection  
Guide  
Amplifier  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73 °F.  
2) “ I ” in the model No. indicates a different frequency type.  
Built-in  
Amplifier-  
separated  
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient  
temperature drift and/or supply voltage fluctuation.  
GX-F/H  
GXL  
GL  
4) Panasonic Electric Works SUNX’s IP68 test method  
1
2
3
4
Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m below +70 °C +158 °F water surface and leave for 30 min.  
1
Regard the heat shock test in  
as one cycle and perform 20 cycles.  
Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.  
1
3
to , insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values.  
After tests  
GX-U/GX-FU/  
GX-N  
5) If using the sensor in an environment where cutting oil droplets splatter, the sensor may deteriorate due to added substances in the oil.  
GX  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
768  
FIBER  
SPECIFICATIONS  
SENSORS  
LASER  
SENSORS  
GX-12 type  
PHOTO-  
ELECTRIC  
SENSORS  
Type  
Front sensing  
Top sensing  
NPN output  
PNP output  
MICRO  
GX-F12A(I)  
GX-H12A(I)  
GX-F12B(I)  
GX-H12B(I)  
GX-F12A(I)-P  
GX-H12A(I)-P  
GX-F12B(I)-P  
GX-H12B(I)-P  
PHOTO-  
ELECTRIC  
SENSORS  
Item  
AREA  
SENSORS  
Max. operation distance (Note 3)  
Stable sensing range (Note 3)  
Standard sensing object  
Hysteresis  
4.0 mm 0.157 in ± 8 %  
0 to 3.3 mm 0 to 0.130 in  
LIGHT  
CURTAINS  
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in  
PRESSURE /  
FLOW  
20 % or less of operation distance (with standard sensing object)  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Repeatability  
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less  
+10  
–15  
Supply voltage  
12 to 24 V DC  
% Ripple P-P 10 % or less  
PARTICULAR  
USE  
Current consumption  
15 mA or less  
SENSORS  
SENSOR  
OPTIONS  
NPN open-collector transistor  
PNP open-collector transistor  
• Maximum source current: 100 mA  
• Maximum sink current: 100 mA  
Output  
SIMPLE  
• Applied voltage: 30 V DC or less (between output and 0 V)  
• Residual voltage: 2 V or less (at 100 mA sink current)  
• Applied voltage: 30 V DC or less (between output and +V)  
• Residual voltage: 2 V or less (at 100 mA source current)  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
Utilization category  
Output operation  
Max. response frequency  
Operation indicator  
Pollution degree  
DC-12 or DC-13  
Normally open  
Normally closed  
Normally open  
Normally closed  
MEASURE-  
MENT  
SENSORS  
500 Hz  
STATIC  
CONTROL  
DEVICES  
Orange LED (lights up when the output is ON)  
3 (Industrial environment)  
ENDOSCOPE  
Protection  
IP68 (IEC), IP68g (JEM) (Note 4, 5)  
LASER  
Ambient temperature  
Ambient humidity  
EMC  
–25 to +70 °C –13 to +158 °F, Storage: – 40 to +85 °C – 40 to +185 °F  
35 to 85 % RH, Storage: 35 to 95 % RH  
EN 60947-5-2  
MARKERS  
PLC /  
TERMINALS  
HUMAN  
MACHINE  
INTERFACES  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure  
10 to 500 Hz frequency, 3 mm 0.118 in amplitude (Max. 20 G) in X, Y and Z directions for two hours each  
10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions for three times each  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
FA  
COMPONENTS  
Sensing  
range  
variation  
Temperature characteristics  
Voltage characteristics  
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ±8 % of sensing range at +23 °C +73 °F  
+10  
MACHINE  
VISION  
SYSTEMS  
Within ±2 % for  
% fluctuation of the supply voltage  
–15  
UV  
CURING  
SYSTEMS  
Material  
Cable  
Enclosure: PBT, Indicator part: Polyester  
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long  
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.  
Front sensing type: 20 g approx., Top sensing type: 20 g approx..  
Cable extension  
Net weight  
Selection  
Guide  
Amplifier  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73 °F.  
2) “ I ” in the model No. indicates a different frequency type.  
Built-in  
Amplifier-  
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient  
temperature drift and/or supply voltage fluctuation.  
separated  
GX-F/H  
GXL  
GL  
4) Panasonic Electric Works SUNX’s IP68 test method  
1
2
3
4
Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m below +70 °C +158 °F water surface and leave for 30 min.  
1
Regard the heat shock test in  
as one cycle and perform 20 cycles.  
Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.  
1
3
to , insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values.  
After tests  
GX-U/GX-FU/  
GX-N  
5) If using the sensor in an environment where cutting oil droplets splatter, the sensor may deteriorate due to added substances in the oil.  
GX  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
769  
FIBER  
SPECIFICATIONS  
SENSORS  
LASER  
SENSORS  
GX-15 type  
PHOTO-  
ELECTRIC  
SENSORS  
NPN output  
Long sensing range  
Front sensing GX-F15A(I) GX-F15B(I) GX-FL15A(I) GX-FL15B(I) GX-F15A(I)-P GX-F15B(I)-P GX-FL15A(I)-P GX-FL15B(I)-P  
GX-H15A(I) GX-H15B(I) GX-HL15A(I) GX-HL15B(I) GX-H15A(I)-P GX-H15B(I)-P GX-HL15A(I)-P GX-HL15B(I)-P  
PNP output  
Type  
MICRO  
PHOTO-  
Long sensing range  
ELECTRIC  
SENSORS  
AREA  
SENSORS  
Item  
Top sensing  
Max. operation distance (Note 3)  
Stable sensing range (Note 3)  
5.0 mm 0.197 in ± 8 %  
8.0 mm 0.315 in ± 8 % (Note 4)  
0 to 6.7 mm 0 to 0.264 in (Note 4)  
5.0 mm 0.197 in ± 8 %  
8.0 mm 0.315 in ± 8 % (Note 4)  
0 to 6.7 mm 0 to 0.264 in (Note 4)  
LIGHT  
CURTAINS  
0 to 4.2 mm 0 to 0.165 in  
0 to 4.2 mm 0 to 0.165 in  
PRESSURE /  
FLOW  
SENSORS  
Iron sheet 20 × 20 × t 1 mm  
0.7874 × 0.7874 × t 0.039 in  
Iron sheet 30 × 30 × t 1 mm  
1.181 × 1.181 × t 0.039 in  
Iron sheet 20 × 20 × t 1 mm  
0.7874 × 0.7874 × t 0.039 in  
Iron sheet 30 × 30 × t 1 mm  
1.181 × 1.181 × t 0.039 in  
Standard sensing object  
INDUCTIVE  
PROXIMITY  
SENSORS  
Hysteresis  
20 % or less of operation distance (with standard sensing object)  
PARTICULAR  
USE  
Repeatability  
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less  
SENSORS  
+10  
Supply voltage  
Current consumption  
12 to 24 V DC  
Ripple P-P 10 % or less  
%
SENSOR  
OPTIONS  
–15  
15 mA or less  
SIMPLE  
WIRE-SAVING  
UNITS  
NPN open-collector transistor  
PNP open-collector transistor  
• Maximum sink current: 100 mA  
• Applied voltage: 30 V DC or less (between output and 0 V)  
• Residual voltage: 2 V or less (at 100 mA sink current)  
• Maximum source current: 100 mA  
• Applied voltage: 30 V DC or less (between output and +V)  
• Residual voltage: 2 V or less (at 100 mA source current)  
WIRE-SAVING  
SYSTEMS  
Output  
MEASURE-  
MENT  
SENSORS  
Utilization category  
Output operation  
Max. response frequency  
Operation indicator  
Pollution degree  
DC-12 or DC-13  
Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed  
250 Hz 150 Hz (Note 5) 250 Hz 150 Hz (Note 5)  
STATIC  
CONTROL  
DEVICES  
ENDOSCOPE  
Orange LED (lights up when the output is ON)  
3 (Industrial environment)  
LASER  
MARKERS  
Protection  
IP68 (IEC), IP68g (JEM) (Note 6, 7)  
PLC /  
TERMINALS  
Ambient temperature  
Ambient humidity  
EMC  
–25 to +70 °C –13 to +158 °F, Storage: – 40 to +85 °C – 40 to +185 °F  
35 to 85 % RH, Storage: 35 to 95 % RH  
EN 60947-5-2  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
FA  
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure  
10 to 500 Hz frequency, 3 mm 0.118 in amplitude (Max. 20 G) in X, Y and Z directions for two hours each  
10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions for three times each  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
Sensing  
range  
variation  
Temperature characteristics  
Voltage characteristics  
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ± 8 % of sensing range at +23 °C +73 °F  
+10  
SYSTEMS  
Within ±2 % for  
% fluctuation of the supply voltage  
–15  
Material  
Cable  
Enclosure: PBT, Indicator part: Polyester  
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long  
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.  
20 g approx.  
Selection  
Guide  
Amplifier  
Built-in  
Cable extension  
Net weight  
Amplifier-  
separated  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73 °F.  
2) “ I ” in the model No. indicates a different frequency type.  
GX-F/H  
GXL  
GL  
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.  
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient  
temperature drift and/or supply voltage fluctuation.  
4) This is the numerical value which the sensor mount onto an insulant plate. When mounted onto a steel or stainless steel plate, insert the optional  
aluminum sheet between the sensor and the plate.  
GX-U/GX-FU/  
GX-N  
5) This is the numerical value which the sensor mount onto an insulant plate. When mounted onto a metallic plate, max. response frequency will decrease.  
6) Panasonic Electric Works SUNX’s IP68 test method  
GX  
1
2
3
4
Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m below +70 °C +158 °F water surface and leave for 30 min.  
1
Regard the heat shock test in  
as one cycle and perform 20 cycles.  
Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.  
1
3
, insulation resistance, voltage withstandability, current consumption, and sensing range must meet the standard values.  
After tests  
to  
7) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
770  
FIBER  
I/O CIRCUIT DIAGRAMS  
SENSORS  
LASER  
SENSORS  
NPN output type  
PHOTO-  
I /O circuit diagram  
ELECTRIC  
SENSORS  
Wiring diagram  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
Color code  
Brown  
Load  
D1  
D2  
(Brown) +V  
AREA  
SENSORS  
+
12 to 24V DC  
Load  
Black  
(Black) Output  
(Note)  
+10  
%
+
12 to 24V DC  
LIGHT  
–15  
+10  
%
Tr  
CURTAINS  
–15  
100 mA max.  
(Blue) 0 V  
Blue  
ZD  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Internal circuit  
Users’ circuit  
PARTICULAR  
USE  
Symbols … D1: Reverse supply polarity protection diode  
D2: Reverse output polarity protection diode  
ZD: Surge absorption zener diode  
SENSORS  
SENSOR  
OPTIONS  
Note: The output does not incorporate a short-circuit protection circuit.  
Do not connect it directly to a power supply or a capacitive load.  
Tr : NPN output transistor  
SIMPLE  
WIRE-SAVING  
UNITS  
PNP output type  
WIRE-SAVING  
SYSTEMS  
I/O circuit diagram  
MEASURE-  
MENT  
Wiring diagram  
SENSORS  
Color code  
(Brown) +V  
STATIC  
Brown  
CONTROL  
DEVICES  
ZD  
+
12 to 24V DC  
100 mA max.  
Tr  
Black  
ENDOSCOPE  
+
12 to 24V DC  
+10  
%
+10  
%
–15  
–15  
(Black) Output  
D2  
D1  
Load  
LASER  
(Note)  
Blue  
Load  
MARKERS  
(Blue) 0 V  
PLC /  
TERMINALS  
Internal circuit  
Users’ circuit  
HUMAN  
MACHINE  
INTERFACES  
Symbols … D1: Reverse supply polarity protection diode  
D2: Reverse output polarity protection diode  
ZD: Surge absorption zener diode  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Note: The output does not incorporate a short-circuit protection circuit.  
Do not connect it directly to a power supply or a capacitive load.  
Tr : PNP output transistor  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Selection  
Guide  
Amplifier  
Built-in  
Amplifier-  
separated  
GX-F/H  
GXL  
GL  
GX-U/GX-FU/  
GX-N  
GX  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
771  
FIBER  
SENSING CHARACTERISTICS (TYPICAL)  
SENSORS  
LASER  
SENSORS  
GX-6 type  
PHOTO-  
ELECTRIC  
SENSORS  
Sensing field  
Correlation between sensing object size and sensing range  
MICRO  
PHOTO-  
4
4
Standard sensing object Standard sensing object  
As the sensing object size becomes smaller than  
Sensing object Sensing object  
0.157  
0.157  
Iron sheet 12 × 12 × t 1 mm Iron sheet 12 × 12 × t 1 mm  
ELECTRIC  
SENSORS  
a
a mm a a in  
×
a
a mm a a in  
× ×  
×
the standard size (iron sheet 12 × 12 × t 1 mm  
0.472 × 0.472 × t 0.039 in), the sensing range  
shortens as shown in the left figure.  
0.472 × 0.472 × t 0.039 in  
0.472 × 0.472 × t 0.039 in  
t 1mm  
L
L
3
L
3
AREA  
L
t 1mm  
t 0.039 in  
0.118  
SENSORS  
0.118  
t 0.039 in  
Top sensing  
Front sensing  
Top sensing  
Front sensing  
LIGHT  
Stainless steel  
2
2
CURTAINS  
(
)
SUS304  
0.079  
0.079  
Iron  
PRESSURE /  
FLOW  
1
1
SENSORS  
0.039  
0.039  
INDUCTIVE  
PROXIMITY  
SENSORS  
Aluminum  
Brass  
10  
0
4
2
0.079  
Left  
0
2
0.079  
Right  
4
0
5
15  
0.591  
20  
PARTICULAR  
USE  
0.157  
0.157  
0.197  
0.394  
0.787  
Center  
Operating point ℓ (mm in)  
SENSORS  
Sensing object side  
length a (mm in)  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
GX-8 type  
Sensing field  
Correlation between sensing object size and sensing range  
WIRE-SAVING  
SYSTEMS  
4
4
Sensing object  
Sensing object  
Standard sensing object Standard sensing object  
As the sensing object size becomes smaller than  
the standard size (iron sheet 15 × 15 × t 1 mm  
0.591 × 0.591 × t 0.039 in), the sensing range  
shortens as shown in the left figure.  
0.157  
0.157  
a
a mm a a in  
× ×  
a
a mm a a in  
×
Iron sheet 15 × 15 × t 1 mm Iron sheet 15 × 15 × t 1 mm  
×
MEASURE-  
MENT  
SENSORS  
0.591 × 0.591 ×t 0.039 in  
L
t 0.039 in  
0.591 × 0.591 × t 0.039 in  
t 1 mm  
t 1 mm  
L
L
t 0.039 in  
L
3
3
Top sensing  
0.118  
0.118  
STATIC  
CONTROL  
DEVICES  
Front sensing  
Top sensing  
Front sensing  
Iron  
2
2
0.079  
Stainless steel  
0.079  
ENDOSCOPE  
(
)
SUS304  
Brass  
1
1
Aluminum  
LASER  
0.039  
0.039  
MARKERS  
PLC /  
0
0
TERMINALS  
5
10  
15  
20  
0.787  
4
2
0.079  
Left  
0
2
4
0.197  
0.394  
0.591  
0.157  
0.079  
0.157  
Center  
Operating point ℓ (mm in)  
Right  
Sensing object side  
length a (mm in)  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
GX-12 type  
FA  
Sensing field  
Correlation between sensing object size and sensing range  
COMPONENTS  
8
8
Sensing  
MACHINE  
VISION  
Standard sensing object Standard sensing object  
Sensing object a a mm a a in  
As the sensing object size becomes smaller than  
the standard size (iron sheet 20 × 20 × t 1 mm  
0.787 × 0.787 × t 0.039 in), the sensing range  
shortens as shown in the left figure.  
×
×
0.315  
0.315  
object  
Iron sheet 20 × 20 × t 1 mm Iron sheet 20 × 20 × t 1 mm  
a
a
a mm  
SYSTEMS  
×
×
t 1 mm  
0.787 × 0.787 × t 0.039 in  
0.787 × 0.787 × t 0.039 in  
L
a in  
t 0.039 in  
Front sensing  
UV  
CURING  
6
6
L
L
L
t 1 mm  
t 0.039 in  
0.236  
0.236  
SYSTEMS  
Top sensing  
Top sensing  
Front sensing  
Iron  
4
4
Stainless steel  
0.157  
0.157  
(
)
SUS304  
Brass  
Selection  
Guide  
2
2
Aluminum  
0.079  
0.079  
Amplifier  
Built-in  
0
Amplifier-  
0
10  
20  
30  
40  
1.575  
separated  
10  
5
0
5
10  
0.394  
0.394  
0.787  
1.181  
0.394  
0.197  
0.197  
Left  
Center  
Right  
Sensing object side  
length a (mm in)  
Operating point ℓ (mm in)  
GX-F/H  
GXL  
GL  
GX-15 type  
GX-U/GX-FU/  
GX-N  
Sensing field  
Correlation between sensing object size and sensing range  
8
8
GX  
Standard sensing object Standard sensing object  
Sensing object  
a
a mm a a in  
×
×
0.315  
0.315  
Sensing object  
Iron sheet 20 × 20 × t 1 mm  
0.787 × 0.787 × t 0.039 in  
Iron sheet 20 × 20 × t 1 mm  
a
a mm a  
a in L  
×
×
As the sensing object size becomes smaller than  
the standard size (iron sheet 20 × 20 × t 1 mm  
0.787 × 0.787 × t 0.039 in), the sensing range  
shortens as shown in the left figure.  
0.787 × 0.  
787 × t 0.039 in  
t 1mm t 0.039 in  
Top sensing  
L
t 1mm  
Front  
6
L
6
L
t 0.039 in  
sensing  
Top sensing  
0.236  
0.236  
Front  
Iron  
sensing  
4
4
Stainless steel  
0.157  
0.157  
(
)
SUS304  
Brass  
Aluminum  
2
2
0.079  
0.079  
0
10  
5
0
5
0
10  
20  
30  
40  
1.575  
10  
0.394  
0.197  
0.197  
0.394  
0.787  
1.181  
0.394  
Left  
Center  
Right  
Sensing object side  
Operating point ℓ (mm in)  
length a (mm in)  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
772  
SENSING CHARACTERISTICS (TYPICAL)  
FIBER  
SENSORS  
LASER  
SENSORS  
GX-15 (Long sensing range) type  
PHOTO-  
ELECTRIC  
SENSORS  
Sensing field  
Correlation between sensing object size and sensing range  
MICRO  
Standard sensing object Standard sensing object  
PHOTO-  
ELECTRIC  
SENSORS  
Sensing object  
Sensing object  
As the sensing object size becomes smaller than  
the standard size (iron sheet 30 × 30 × t 1 mm  
1.181 × 1.181 × t 0.039 in), the sensing range  
shortens as shown in the left figure.  
Iron sheet 30 × 30 × t 1 mm Iron sheet 30 × 30 × t 1 mm  
a
a mm a a in  
×
a
a mm a a in  
× ×  
×
1.181 × 1.181 × t 0.039 in  
1.181 × 1.181 × t 0.039 in  
10  
10  
L
L
t 1mm  
t 1mm t 0.039 in  
Top sensing  
L
0.394  
0.394  
AREA  
t 0.039 in  
Front sensing  
L
Top  
SENSORS  
Front  
Iron  
sensing  
sensing  
Stainless steel  
(
)
LIGHT  
SUS304  
CURTAINS  
5
5
0.197  
0.197  
PRESSURE /  
FLOW  
Brass  
Aluminum  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
0
0
10  
20  
0.787  
30  
40  
1.575  
0
10  
5
5
0.197  
Right  
10  
0.394  
PARTICULAR  
USE  
0.394  
1.181  
0.394  
0.197  
Left  
Center  
Operating point ℓ (mm in)  
Sensing object side  
length a (mm in)  
SENSORS  
SENSOR  
OPTIONS  
PRECAUTIONS FOR PROPER USE  
Refer to General precautions.  
SIMPLE  
WIRE-SAVING  
UNITS  
GX-8 type  
WIRE-SAVING  
SYSTEMS  
Never use this product as a sensing device  
for personnel protection.  
M3 (length 12 mm 0.472 in) truss head  
Make sure to use a M3  
(length: 12 mm 0.472 in or  
more) truss head screw.  
The tightening torque  
should be 0.7 N·m or less.  
Do not use a flat head  
screw or a pan head  
screw.  
MEASURE-  
MENT  
screw (Accessory for MS-GXL8-4)  
In case of using sensing devices for  
personnel protection, use products which  
meet laws and standards, such as OSHA,  
ANSI or IEC etc., for personnel protection  
applicable in each region or country.  
SENSORS  
MS-GXL8-4 (Accessory)  
STATIC  
CONTROL  
DEVICES  
M3 × 0.5 mm 0.020 in tapped hole  
(Depth: 8 mm 0.315 in or more)  
or ø3.4 mm ø0.134 in thru-hole  
ENDOSCOPE  
11.5 mm 0.453 in  
If mounting using nut  
and washers  
(Accessories for MS-GXL8-4)  
LASER  
MARKERS  
Mounting  
ø2.4 mm ø0.098 in hole  
(Depth: 3 mm 0.315 in or more)  
PLC /  
GX-6 type  
TERMINALS  
GX-12 type  
Use the optional sensor mounting bracket when  
installing.  
HUMAN  
MACHINE  
M3 (length 12 mm 0.472 in or more)  
pan head screw  
The tightening torque  
should be 0.7 N·m or less.  
INTERFACES  
(Purchase separately.)  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
<When using MS-GX6-1 (recommended)>  
To mount the sensor with  
a nut, the mounting hole  
diameter should be ø3.4  
mm ø0.134 in. Further, the  
hole in which the boss is  
inserted should be ø2.5  
mm ø0.098 in and 3 mm  
0.118 in, or more, deep.  
M3 × 0.5 mm 0.020 in tapped hole  
(Depth: 10 mm 0.394 in or more)  
or ø3.4 mm ø0.134 in thru-hole  
To mount the sensor with  
a nut, the mounting hole  
diameter should be  
FA  
COMPONENTS  
MACHINE  
VISION  
M3 pan head screw  
(
16 mm 0.630 in  
ø3.4 mm ø0.134 in.  
Purchase separately.)  
SYSTEMS  
If mounting using nut  
and washers  
1
Insert the sensor into the  
bracket as shown on the  
right.  
UV  
CURING  
SYSTEMS  
MS-GX6-1  
Hook  
(Purchase separately.)  
Cable  
M3 x 0.5 mm 0.020 in  
tapped hole or  
ø2.5 mm ø0.098 in hole  
(Depth: 3 mm 0.118 in or more)  
Groove  
ø3.4 mm ø0.134 in hole  
2
Push the sensor until the  
bracket hook is lodged in  
the groove on the upper  
portion of the sensor.  
Fix the bracket in place  
with M3 pan head screw.  
22 mm 0.866 in  
GX-15 type  
Selection  
Guide  
ø3.4 mm  
Amplifier  
Built-in  
M3 pan head screws or  
truss head screws  
If mounting using nut  
and washers  
The tightening torque  
should be 1 N·m or less.  
To mount the sensor with  
a nut, the mounting hole  
diameter should be ø3.4  
mm ø0.134 in.  
ø
0.134 in hole  
3
Amplifier-  
(
Purchase separately.)  
Do not use flat head  
screws.  
separated  
M3 x 0.5 mm 0.020 in  
tapped holes or  
ø3.4 mm ø0.134 in holes  
GX-F/H  
GXL  
GL  
<When using MS-GL6-1 / MS-GL6-2>  
To mount the sensor with a nut, the mounting hole  
diameter should be ø3.4 mm ø0.134 in.  
9 mm  
0.354 in  
GX-U/GX-FU/  
GX-N  
M3 pan head screw  
(Purchase separately.)  
M3 pan head screws  
(Purchase separately.)  
If mounting using nuts  
and washers  
GX  
(Purchase separately.)  
MS-GXL15  
(Sensor mounting bracket)  
MS-GL6-2  
MS-GL6-1  
ø2.4 mm  
Aluminum sheet (Optional)  
MS-A15F  
MS-A15H  
M3 x 0.5 mm 0.020 in  
tapped hole or  
When installing the long  
sensing range type on iron  
or stainless steel plate, put  
the optional aluminum sheet  
in between the sensor and  
the plate.  
M3 x 0.5 mm 0.020 in  
tapped holes or  
0.098 in hole  
ø3.4 mm ø0.134 in hole  
ø3.4 mm ø0.134 in holes  
10 mm  
13.6 mm  
0.535 in  
0.394 in  
If mounting using nut  
and washers  
(Purchase separately.)  
If mounting using nuts  
and washers  
(Purchase separately.)  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
773  
Refer to General precautions.  
FIBER  
PRECAUTIONS FOR PROPER USE  
SENSORS  
LASER  
Influence of surrounding metal  
SENSORS  
Sensing range  
PHOTO-  
ELECTRIC  
SENSORS  
• The sensing range is specified for the standard sensing  
object. With a non-ferrous metal, the sensing range is  
obtained by multiplying with the correction coefficient  
specified below. Further, the sensing range also changes  
if the sensing object is smaller than the standard sensing  
object or if the sensing object is plated.  
When there is a metal near the sensor, keep the minimum  
separation distance specified below.  
MICRO  
PHOTO-  
Front sensing type  
ELECTRIC  
SENSORS  
Metal  
Metal  
AREA  
SENSORS  
B
Metal  
C
C
LIGHT  
A
Correction coefficient  
CURTAINS  
Model  
No.  
GX-F6 GX-F8 GX-F12 GX-F15  
GX-H6 GX-H8 GX-H12 GX-H15  
GX-FL15 GX-HL15  
PRESSURE /  
FLOW  
type  
type  
SENSORS  
type  
type  
type  
type  
Metal  
Iron  
GX-F6 type GX-F8 type GX-F12 type GX-F15 type GX-FL15 type  
INDUCTIVE  
PROXIMITY  
SENSORS  
1
1
1
1
1
1
6 mm 0.236 in  
(Note 1)  
8 mm 0.315 in  
(Note 2)  
A
7.4 mm 0.291 in 7.1 mm 0.280 in  
8 mm 0.315 in  
Stainless steel  
(SUS304)  
0.76 approx. 0.76 approx. 0.79 approx. 0.68 approx. 0.70 approx. 0.76 approx.  
PARTICULAR  
USE  
B
C
8 mm 0.315 in  
3 mm 0.118 in  
8 mm 0.315 in 20 mm 0.787 in 20 mm 0.787 in 30 mm 1.181 in  
3 mm 0.118 in 7 mm 0.276 in 7 mm 0.276 in 10 mm 0.394 in  
Brass  
0.50 approx. 0.50 approx. 0.56 approx. 0.47 approx. 0.45 approx. 0.50 approx.  
0.48 approx. 0.48 approx. 0.53 approx. 0.45 approx. 0.43 approx. 0.48 approx.  
SENSORS  
Aluminum  
SENSOR  
OPTIONS  
Notes: 1) When using MS-GX6-1 (recommended mounting bracket), the  
distance “A” including the thickness of mounting bracket will be  
6.4 mm 0.252 in.  
SIMPLE  
WIRE-SAVING  
UNITS  
Wiring  
2) The GXL-FL15 type should be mounted on an insulator. To mount  
it on an iron or stainless steel, use the enclosed aluminum sheet.  
The output does not incorporate a short-circuit protection  
circuit. Do not connect it directly to a power supply or a  
capacitive load.  
WIRE-SAVING  
SYSTEMS  
Top sensing type  
MEASURE-  
MENT  
Metal  
D
Metal  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Others  
G
Metal  
Do not use during the initial transient time (50 ms) after  
the power supply is switched on.  
G
ENDOSCOPE  
E
F
LASER  
GX-H6 type GX-H8 type GX-H12 type GX-H15 type GX-HL15 type  
MARKERS  
D
E
3 mm 0.118 in  
4 mm 0.157 in  
7 mm 0.276 in  
6 mm 0.236 in 12 mm 0.472 in  
PLC /  
TERMINALS  
10 mm 0.394 in 10 mm 0.394 in 20 mm 0.787 in 20 mm 0.787 in 30 mm 1.181 in  
10 mm 0.394 in  
(Note)  
3 mm 0.118 in 10 mm 0.394 in  
HUMAN  
MACHINE  
F
2 mm 0.079 in  
2 mm 0.079 in  
3 mm 0.118 in  
3 mm 0.118 in  
3 mm 0.118 in  
3 mm 0.118 in  
0 mm  
0 in  
INTERFACES  
G
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Note: When GX-HL15 type is mounted on an insulator or seated on the  
enclosed aluminum sheet, the distance “F” can be zero.  
FA  
COMPONENTS  
Mutual interference prevention  
MACHINE  
VISION  
When two or more sensors are installed in parallel or face  
to face, keep the minimum separation distance specified  
below to avoid mutual interference.  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Front sensing  
H
J
Between “I” type  
and non “I” type  
0 mm 15 mm  
(Note 2) 0.591 in  
GX-F6  
GX-H6  
type  
Between two “I” types 13 mm 25 mm  
or two non “I” types  
Selection  
Guide  
0.512 in 0.984 in  
Between “I” type  
and non “I” type  
0 mm 15 mm  
(Note 2) 0.591 in  
Amplifier  
GX-F8  
GX-H8  
type  
H
H
Built-in  
Amplifier-  
Between two “I” types 20 mm 35 mm  
or two non “I” types  
J
separated  
0.787 in 1.378 in  
Between “I” type  
and non “I” type  
0 mm 25 mm  
(Note 2) 0.984 in  
GX-F12  
GX-H12  
type  
GX-F/H  
GXL  
GL  
Between two “I” types 25 mm 50 mm  
or two non “I” types  
0.984 in 1.969 in  
Top sensing  
Between “I” type  
and non “I” type  
0 mm 25 mm  
(Note 2) 0.984 in  
GX-F15  
GX-H15  
type  
Between two “I” types 45 mm 70 mm  
or two non “I” types  
GX-U/GX-FU/  
GX-N  
1.772 in 2.756 in  
Between “I” type  
and non “I” type  
0 mm 25 mm  
(Note 2) 0.984 in  
J
H
GX-FL15  
GX-HL15  
type  
GX  
Between two “I” types 110 mm 170 mm  
or two non “I” types  
3.059 in 6.693 in  
Notes: 1) “I” in the model No. specifies  
the different frequency type.  
2) Close mounting is possible for up to two sensors.  
When mounting three sensors or more at an equal spacing, align  
the model with “I” and the model without “I” alternately. The minimum  
value of dimension “H” should be as given below.  
GX-F6 / H6 type: 3.5mm 0.138 in  
GX-F8 / H8 type: 6mm 0.236 in  
GX-F12 / H12 type: 6.5mm 0.256 in  
GX-F15 / H15 type: 15mm 0.591 in  
GX-FL15 / HL15 type: 47.5mm 1.870 in  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
774  
DIMENSIONS (Unit: mm in)  
FIBER  
The CAD data in the dimensions can be downloaded from our website.  
SENSORS  
LASER  
SENSORS  
Sensor  
Sensor  
GX-F6□  
GX-H6□  
PHOTO-  
ELECTRIC  
SENSORS  
3
MICRO  
0.118  
PHOTO-  
ELECTRIC  
SENSORS  
ø3 ø0.118 cable,  
1 m 3.281 ft long  
Operation indicator  
(Orange)  
6
0.236  
11  
6
0.433 0.236  
24.5  
AREA  
0.5  
SENSORS  
0.020  
0.965  
11.5  
6
0.453 0.236  
25  
ø3 ø0.118 cable,  
1 m 3.281 ft long  
Sensing direction  
2.6  
LIGHT  
0.5  
0.5  
0.984  
CURTAINS  
0.020  
6
0.020  
3
0.5  
0.236  
0.102  
6
0.118  
2.5  
0.020  
PRESSURE /  
FLOW  
0.098  
6
0.236  
0.236  
SENSORS  
Operation indicator (Orange)  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
Sensor  
Sensor  
GX-F8□  
GX-H8□  
SENSORS  
SENSOR  
OPTIONS  
ø3.1 ø0.122 mounting hole  
5.4 0.213 6.3 0.248  
Operation indicator (Orange)  
Operation indicator  
(Orange)  
Sensing  
direction  
SIMPLE  
7.4  
WIRE-SAVING  
UNITS  
0.291  
2.95  
8
0.116  
0.315  
ø3 ø0.118 cable,  
1 m 3.281 ft long  
18.5  
0.728  
6.8  
WIRE-SAVING  
SYSTEMS  
Sensing  
direction  
8.55  
0.337  
0.268  
2 0.079  
3.7  
7.7  
11.5  
23  
MEASURE-  
MENT  
R4.25  
3.85  
22.5  
ø9 ø0.354  
0.146  
0.303  
0.453  
0.906  
0.886  
R0.167 0.152  
9.1 0.358  
2.5  
2.4  
SENSORS  
ø3.1 ø0.12  
0.095  
9.75  
6.5  
mounting hole  
0.384  
8.2 0.323  
STATIC  
0.256  
4.8 0.189 5.3 0.209  
CONTROL  
DEVICES  
ø3 ø0.118 cable,  
1 m 3.281 ft long  
2.65  
8.6  
4.6  
8
5.4  
1
0.098  
5
25  
0.104  
1
0.339  
0.181  
0.315  
0.213  
0.039  
0.197  
0.984  
ENDOSCOPE  
0.039  
6.3  
5.3  
0.248  
0.209  
LASER  
MARKERS  
PLC /  
Sensor  
Sensor  
GX-F12□  
GX-H12□  
TERMINALS  
Operation indicator  
(Orange)  
ø3 ø0.118 cable,  
HUMAN  
1 m 3.281 ft long  
MACHINE  
INTERFACES  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Sensing  
direction  
6.8 0.268 7.8 0.307  
7.1  
0.280  
Operation indicator  
(Orange)  
ø3.1 ø0.122 mounting hole  
ø6 ø0.236 screw seat,  
1.4 0.055 deep  
FA  
22.2  
3.3 0.130  
1.5 0.059  
12  
COMPONENTS  
0.874  
0.472  
8.65 0.341  
12  
MACHINE  
VISION  
4.8 0.189  
0.472  
3 0.118  
5.5  
Sensing  
direction  
12  
SYSTEMS  
ø2.3  
R6.25 R0.246  
0.217  
0.472  
ø0.091  
UV  
27  
27.8  
11.05  
CURING  
SYSTEMS  
16  
16  
12  
0.472  
13  
1.063  
1.095  
0.630  
12.5  
ø12.5 ø0.492  
0.435  
0.630  
0.512  
0.492  
6.2  
6.5 0.256  
0.244  
ø3.1 ø0.12  
mounting hole  
12.4  
5 0.197  
16  
3.1 5.8  
0.488  
ø2.3  
ø0.091  
2.5  
1.5  
0.630  
ø6 ø0.236 screw seat,  
0.12 0.228  
4.4 0.173  
0.098  
0.059  
0.8 0.032 deep  
27.4  
4.4  
Selection  
Guide  
1.079  
0.173  
ø3 ø0.118 cable,  
2.8  
6.8  
1 m 3.281 ft long  
Amplifier  
Built-in  
0.110  
5.2  
0.268  
7.8  
0.205  
Amplifier-  
0.307  
5.6  
separated  
0.221  
GX-F/H  
GXL  
GL  
Sensor  
Sensor  
GX-F(L)15  
GX-H(L)15□  
Operation indicator (Orange)  
2-ø3.1 ø0.122 holes  
ø3 ø0.118 cable, 1 m 3.281 ft long  
31.5  
ø3 ø0.118 cable,  
1 m 3.281 ft long  
GX-U/GX-FU/  
GX-N  
1.240  
7.5  
20.5  
0.295  
0.807  
GX  
9
Sensing direction  
0.354  
9
15  
0.591  
0.354  
26  
1.024  
2-ø3.1 ø0.122 holes  
21.5  
Sensing  
direction  
0.846  
ø15.5 ø0.610  
ø15.5  
11.95  
0.470  
ø0.610  
3
0.118  
14.15  
0.557  
7.8  
5.3  
5.3  
0.307  
0.209  
0.209  
14.15  
0.557  
16.5  
15.65  
0.616  
0.650  
8
8.5  
0.335  
0.315  
2.3  
15  
0.591  
2.8  
Operation indicator (Orange)  
3.7  
0.146  
5.7  
0.091  
2.8  
7.2  
29.5  
1.161  
0.110  
0.224  
0.110 0.283  
Rectangular-shaped Inductive Proximity Sensor GX-F/HSERIES  
775  
FIBER  
DIMENSIONS (Unit: mm in)  
The CAD data in the dimensions can be downloaded from our website.  
SENSORS  
LASER  
SENSORS  
Sensor mounting bracket for GX-6 type (Optional)  
Sensor mounting bracket for GX-6 type (Optional)  
MS-GX6-1  
MS-GL6-1  
PHOTO-  
ELECTRIC  
SENSORS  
25.75  
ø3.1  
Mounting hole dimensions  
1.014  
25.35  
0.998  
ø0.122  
MICRO  
PHOTO-  
Mounting hole dimensions  
6
0.236  
ELECTRIC  
SENSORS  
13.6  
ø2.4 ø0.094 hole,  
22  
0.535  
6
6.8  
2-3.2 × 3.8 0.126 × 0.150 oblong holes  
3 0.118 or more deep  
0.866  
0.236  
0.268  
AREA  
SENSORS  
3.55  
22.2  
5.5  
2.3  
(
)
0.217  
0.140  
0.874  
0.091  
2-M3 × 0.5 0.020 tapped holes  
M3 × 0.5 0.020 tapped hole,  
8 0.315 or more deep  
5.6  
(or 2-ø3.4 ø0.134 holes)  
LIGHT  
6.4  
t 0.4  
0.220  
CURTAINS  
0.252  
19.6 0.772 t 0.016  
(Note)  
Note: 20 mm 0.787 in with the sensor fitted.  
t 0.4  
PRESSURE /  
FLOW  
t 0.016  
2
0.079  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
Sensor mounting bracket for GX-6 type (Optional)  
Sensor mounting bracket for GX-8 type (Optional)  
MS-GL6-2  
MS-GXL8-4  
SENSORS  
SENSOR  
OPTIONS  
Mounting hole dimensions  
Mounting hole dimensions  
6
SIMPLE  
WIRE-SAVING  
UNITS  
0.236  
Center of  
9
10  
ø2.4 ø0.094 hole,  
sensing  
0.354  
0.394  
3 0.118 or more deep  
2
2
6
3.2 × 3.8 0.126 × 0.150 oblong hole  
2.3  
0.079  
0.079  
0.236  
0.091  
WIRE-SAVING  
SYSTEMS  
5.3  
0.209  
5.6  
5.5  
0.217  
ø2.4  
ø0.094  
hole  
0.3  
0.012  
(11.5)  
(0.453)  
M3 × 0.5 0.020 tapped hole  
(or ø3.4 ø0.134 hole)  
t 0.4  
t 0.016  
M3 × 0.5 0.020  
tapped hole,  
8 0.315 or more deep  
11.5  
MEASURE-  
MENT  
2.2  
0.087  
0.220  
t 0.4  
t 0.016  
1.5  
0.453  
13.2 0.520  
0.059  
3.3  
0.130  
SENSORS  
(16.2)  
15.8  
(Note)  
(0.638)  
0.622  
Note: 13.4 mm 0.528 in with the sensor fitted.  
STATIC  
CONTROL  
DEVICES  
4.5 0.177  
ø3.1 ø0.122 hole  
ENDOSCOPE  
LASER  
Material: Stainless steel (SUS304)  
MARKERS  
1 pc. each of M3 (length 12 mm 0.472 in) truss head screw,  
nut, spring washer and plain washer is attached.  
PLC /  
TERMINALS  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
CONSUMPTION  
VISUALIZATION  
COMPONENTS  
Sensor mounting bracket for GX-15 type (Optional)  
Aluminum sheet (Optional)  
MS-GXL15  
MS-A15F MS-A15H  
FA  
t 2  
COMPONENTS  
t 0.079  
30  
1.181  
MACHINE  
VISION  
14  
SYSTEMS  
0.551  
2.5  
2-ø3.2  
ø0.126  
9
0.098  
UV  
CURING  
0.354  
39.5  
7
1.555  
2-3.2 × 5.1  
SYSTEMS  
0.276  
0.126 × 0.201  
oblong holes  
MS-A15H:  
4
(
)
30 1.181  
0.157  
2-M3 × 0.5 0.020 tapped holes  
Selection  
Guide  
Material: SPCC  
9
t = 0.3 0.012  
0.354  
21  
Amplifier  
Built-in  
1.9  
1.9  
0.075  
0.827  
0.075  
Amplifier-  
separated  
GX-F/H  
GXL  
GL  
GX-U/GX-FU/  
GX-N  
GX  
776  
MEMO  

相关型号:

GX-F12AI

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F12AI-P

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F12B

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F12B-P

Inductive Sensor, 0mm Min, 3.3mm Max, Rectangular
PANASONIC

GX-F12B-P

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F12BI

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F12BI-P

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F15A

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F15A-P

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F15AI

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F15AI-P

Rectangular-shaped Inductive Proximity Sensor
OMRON

GX-F15B

Rectangular-shaped Inductive Proximity Sensor
OMRON