H3DE-F [OMRON]

Solid-state Timer;
H3DE-F
型号: H3DE-F
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Solid-state Timer

文件: 总34页 (文件大小:1417K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HSoli3d-sDtateETimer  
DIN Track Mounted, Standard 22.5-mm Width Timer Range  
• A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H)  
• 12-VDC model available for a specific application. (H3DE-M2)  
• Nameplate provided for easy timer identification and management.  
Terminal clamp left open when delivered.  
• Finger protection terminal block to meet VDE0106/P100.  
• Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.  
• Incorporates environment-friendly, cadmium-free contacts. (except for H3DE-H)  
• High immunity to inverter noise.  
• Approved by UL and CSA.  
• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.  
Broad Line-up of H3DE Series  
H3DE  
H3DE-M/S  
H3DE-F  
H3DE-G  
H3DE-H  
Standard Timer  
H3DE-M  
H3DE-S  
Twin Timer  
H3DE-F  
Star-delta Timer  
H3DE-G  
Power OFF-delay Timer  
H3DE-H  
Contents  
Solid-state Timer  
H3DE-M/-S......................................................................................................................................  
H3DE-F...........................................................................................................................................  
H3DE-G ..........................................................................................................................................  
H3DE-H...........................................................................................................................................  
Common to ALL Timers  
B-53  
B-63  
B-69  
B-75  
Accessories.....................................................................................................................................  
Precautions.....................................................................................................................................  
B-81  
B-82  
Solid-state Timer H3DE  
B-51  
52  
Solid-state Timer H3DE  
HSoli3d-sDtateEMu-ltiM-fun/ct-ioSnal Timer  
• Eight operating modes (H3DE-M) and four operating modes  
(H3DE-S) cover a wide range of applications.  
• Programmable contact enables the building of a self-holding re-  
lay circuit (-@2 models).  
• A wide time setting range of 0.10 s to 120 h.  
Model Number Structure  
Model Number Legend  
H3DE -  
1
2
1. M: Multi-function type  
S: Standard type  
2. 2: DPDT  
1: SPDT  
Ordering Information  
List of Models  
Supply voltage  
Control output  
Model  
Multi-function type  
Contact output: DPDT (time-limit output SPDT and switchable H3DE-M2  
SPDT (time-limit ←→ instantaneous)) (see note)  
Contact output: DPDT (time-limit output SPDT and switchable H3DE-M2  
Standard type  
12 VDC  
---  
24 to 230 VAC/DC  
H3DE-S2  
H3DE-S1  
SPDT (time-limit ←→ instantaneous))  
(see note)  
Contact output: SPDT (time-limit output SPDT)  
H3DE-M1  
Note: Specify both the model number and supply voltage when ordering H3DE-M2.  
Example: H3DE-M2 24 to 230 VAC/DC  
Supply voltage  
Accessories (Order Separately)  
Mounting Track  
50 cm (l) x 7.3 mm (t)  
1 m (l) x 7.3 mm (t)  
1 m (l) x 16 mm (t)  
PFP-M  
PFP-50N  
PFP-100N  
PFP-100N2  
End Plate  
Spacer  
PFP-S  
Solid-state Multi-functional Timer H3DE-M/-S  
B-53  
Specifications  
General  
Item  
H3DE-M2  
H3DE-M1  
H3DE-S2  
A: ON-delay  
B2: Flicker ON start  
E: Interval  
H3DE-S1  
Operating mode  
A: ON-delay (Signal or Power)  
B: Flicker OFF start (Signal or Power)  
B2: Flicker ON start (Signal or Power)  
C: Signal ON/OFF-delay  
J: One-shot  
D: Signal OFF-delay  
E: Interval (Signal or Power)  
G: Signal ON/OFF-delay  
J: One-shot (Signal or Power)  
Clamps two 2.5 mm2 max. bar terminals without sleeves.  
Terminal block  
Terminal screw tightening  
torque  
0.98 N·m max. {approx. 10 kgf·cm max.}  
Input type  
Voltage input  
---  
Output type  
Relay: DPDT  
Relay: SPDT  
Relay: DPDT  
Relay: SPDT  
Mounting method  
Attachment  
DIN track mounting (see note)  
Nameplate  
Approved standards  
UL508, CSA 22.2 No.14  
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100  
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)  
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.  
Time Ranges  
Time scale display  
Time unit display  
sec  
min  
0.1 to 1.2 min  
1 to 12 min  
hrs  
10 h  
x 0.1  
x 1  
0.1 to 1.2 s  
1 to 12 s  
0.1 to 1.2 h  
1 to 12 h  
1 to 12 h  
10 to 120 h  
Note: When the main dial is set to “0” for all settings, the output will operate instantaneously.  
Ratings  
Rated supply voltage  
(see notes 1 and 2)  
24 to 230 VAC/DC (50/60 Hz)  
12 VDC (H3DE-M2 model only)  
Operating voltage range  
Power reset  
85% to 110% of rated supply voltage  
Minimum power-off time: 0.1 s  
2.4 VAC/DC max.  
Reset voltage  
Power consump- H3DE-M1  
tion (see note 3)  
AC: approx. 4.3 VA (2.2 W) at 230 VAC  
DC: approx. 0.7 W at 24 VDC  
H3DE-M2  
AC: approx. 4.8 VA (2.4 W) at 230 VAC  
DC: approx. 1.0 W at 24 VDC  
H3DE-S1  
AC: approx. 2.7 VA (1.6 W) at 230 VAC  
DC: approx. 0.7 W at 24 VDC  
H3DE-S2  
AC: approx. 3.2 VA (1.9 W) at 230 VAC  
DC: approx. 1.0 W at 24 VDC  
Voltage input  
Max. permissible capacitance between input lines (terminals B1 and A2): 2000 pF  
Load connectable in parallel with inputs (terminals B1 and A2)  
H-level: 20.4 to 253 VAC/DC  
L-level: 0 to 2.4 VAC/DC  
Control output  
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)  
5 A at 30 VDC with resistive load (cosφ = 1)  
Ambient temperature  
Operating: 10°C to 55°C (with no icing)  
Storage:  
25°C to 65°C (with no icing)  
Ambient humidity  
Operating: 35% to 85%  
Note: 1. DC ripple rate: 20% max.  
2. Since an inrush current of 0.25 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning on or off  
the power supply to the Timer with a solid-state output such as a sensor.  
3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of  
the H3DE-M@ includes the input circuit with the B1 and A1 terminals short-circuited.  
B-54  
Solid-state Multi-functional Timer H3DE-M/-S  
Characteristics  
Accuracy of operating  
time  
1% max. of FS ( 1% 10 ms max. at 1.2-s range) (see note 1)  
Setting error  
10% 50 ms max. of FS (see note 1)  
50 ms min. (see note 1)  
Signal input time  
Influence of voltage  
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)  
Influence of temperature 2% max. of FS ( 2% 10 ms max. at 1.2-s range)  
Insulation resistance  
Dielectric strength  
100 Mmin. at 500 VDC  
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min.  
Between control output terminals and operating circuit: 2,000 VAC for 1 min.  
Between contacts of different polarities: 2,000 VAC for 1 min.  
Between contacts not located next to each other: 1,000 VAC for 1 min.  
Vibration resistance  
Shock resistance  
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz  
Destruction: 0.75-mm single amplitude at 10 to 55 Hz  
Malfunction: 100 m/s2  
Destruction: 1,000 m/s2  
Contact material  
AGNi+gold plating (Use the G6RN-1 at 12 VDC.)  
Impulse withstand volt- 3 kV (between power terminals)  
age  
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)  
Noise immunity  
Static immunity  
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) 1.5 kV  
Malfunction: 4 kV  
Destruction: 8 kV  
Life expectancy  
EMC  
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)  
Electrical:  
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)  
(see note 2)  
(EMI)  
EN61812-1  
Emission Enclosure:  
Emission AC Mains:  
Harmonic Current:  
Voltage Fluctuation and Flickering:  
(EMS)  
EN55011 Group 1 class B  
EN55011 Group 1 class B  
EN61000-3-2  
EN61000-3-3  
EN61812-1  
Immunity ESD:  
EN61000-4-2: 6 kV contact discharge (level 3)  
8 kV air discharge (level 3)  
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)  
Immunity Burst:  
EN61000-4-4: 2 kV power port and output port (level 3)  
1 kV control port with capacitive clamp (level 3)  
EN61000-4-5: 2 kV common mode (level 3)  
1 kV differential mode (level 3)  
Immunity Surge:  
Degree of protection  
Weight  
IP30 (Terminal block: IP20)  
120 g  
Note: 1. With the H3DE-M@, if the voltage exceeds 26.4 VAC/DC, the following hold at signal OFF for C, D, and G modes:  
Accuracy of operating time: 1% 50 ms max. at 1.2-s range  
Setting error: 10% +100/50 ms max.  
Signal input time: 100 ms min.  
2. For reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).  
A maximum current of 0.1 A can be switched if L/R is 7 ms.  
In both cases, a life of 100,000 operations can be expected.  
The minimum applicable load is 10 mA at 5 VDC (failure level: P).  
Solid-state Multi-functional Timer H3DE-M/-S  
B-55  
Connections  
Block Diagram  
H3DE-M1/-M2  
Zero setting  
detection  
circuit  
AC (DC) input  
Time scale/  
unit selectors  
Operating  
mode selector  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output circuit  
Indicator  
circuit  
Start input  
Input circuit  
Power-ON Output  
indicator  
indicator  
H3DE-S1/-S2  
Zero setting  
detection  
circuit  
AC (DC) input  
Time scale/  
Operating  
unit selectors  
mode selector  
Output circuit  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Indicator  
circuit  
Power-ON Output  
indicator  
indicator  
I/O Functions  
Item  
H3DE-M1/-M2  
H3DE-S1/-S2  
Input  
Start  
Starts operation.  
No input is available.  
Output  
Control output  
Outputs are turned ON according to designated out- Outputs are turned ON according to designated out-  
put mode when preset value is reached. (See note.) put mode when preset value is reached. (see note.)  
Note: When the output type selector switch on the bottom of the Timer is set to the instantaneous side, the relay R2 (terminal numbers 21/25, 22/  
26, and 24/28) becomes an instantaneous contact and turns ON/OFF in synchronization with the changes in the power supply.  
B-56  
Solid-state Multi-functional Timer H3DE-M/-S  
Terminal Arrangement  
H3DE-M1  
H3DE-M2  
H3DE-S1  
H3DE-S2  
25/21  
A1 15  
25/21  
A1 15  
A1 15  
A1 15  
(see note 1)  
(see note 1)  
R1  
15  
R1  
15  
R1  
15  
R2  
25/21  
R1  
15  
R2  
25/21  
18 16 28/24 26/22  
28/24 26/22  
18 16  
28/2426/22  
18 16  
18 16  
B1  
18 16 A2  
28/24 26/22  
B1  
18 16 A2  
18 16 A2  
18 16 A2  
(see note 2)  
(see note 2)  
(see note 2)  
(see note 2)  
(DIN notation)  
(DIN notation)  
(DIN notation)  
(DIN notation)  
Note: 1. The relay R2 can be set to either instantaneous or time-limit contact using the switch located on the bottom of the Timer.  
2. DC supply voltage does not require the designation of polarity.  
3. The contact symbol for the H3DE is indicated with  
because it offers multiple operating modes and is different from the delayed  
contact for conventional timers.  
Input Connections  
The inputs of the H3DE-M1/-M2 are voltage (voltage imposition or open) inputs.  
No-contact Input  
No-contact Input  
Contact Input  
(Connection to PNP output sensor.)  
(Connection to NPN output sensor.)  
Sensor  
Timer  
(+)  
A2  
Timer  
Timer  
24 VDC  
()  
B1  
A1  
B1  
A1  
B1  
A1  
(+)  
Start  
Start  
24 VDC  
()  
A2  
A2  
Operates with PNP transistor ON  
Operates with relay ON  
Sensor  
Operates with NPN transistor ON  
Voltage Input Signal Levels  
1. Transistor ON  
Residual voltage: 1 V max.  
(Voltage between terminals B1 and A2 must be more than  
the rated "H-level" voltage (20.4 VDC min.).)  
No-contact  
input  
2. Transistor OFF  
Leakage current: 0.01 mA max.  
(Voltage between terminals B1 and A2 must be less than  
the rated "L-level" voltage (2.4 VDC max.).)  
Use contacts that can adequately switch 0.1 mA at each  
voltage to be imposed. (When the contacts are ON or  
OFF, voltage between terminals B1 and A2 must be within  
the following ranges:  
Contact  
input  
When contacts are ON: 20.4 to 253 VAC/DC  
When contacts are OFF: 0 to 2.4 VAC/DC  
Solid-state Multi-functional Timer H3DE-M/-S  
B-57  
Operation  
Basic Operation  
Setting of Selector  
The selectors can be turned clockwise and counterclockwise to  
select the desired time unit, time scale, or operating mode.  
Selection of Time Unit and Time Scale  
The desired time unit (s, m, h, or 10h) can be displayed in the time  
unit display window above the time setting dial by turning the time  
unit selector located at the upper right corner of the front panel. Time  
scale (0.1 or 1) is selected with the time scale selector at the upper  
left corner of the front panel, it appears in the time scale display win-  
dow above the selector.  
Each selector has a snap mechanism that secures the selector at a  
given position. Set the selector at a position at which it is secured. Do  
not set it midway between two securing positions or a malfunction  
could result from improper setting.  
Time unit display  
window  
Time scale display  
window  
Operating  
mode selector  
Time scale  
selector  
Operating  
mode display  
window  
Time unit selector  
Selection of Operating Mode  
The H3DE-M/-S can be set to any one of the operating modes A to J.  
Turn the operating mode selector with a screwdriver until the desired  
operating mode (A, B, C, B2, D, E, J, or G for the H3DE-M and A, E,  
J, or B2 for the H3DE-S) appears in the operating mode display win-  
dow located below the selector.  
B-58  
Solid-state Multi-functional Timer H3DE-M/-S  
Timing Chart  
Note: 1. The minimum power reset time is 0.1 s and the minimum signal input time is 0.05 s.  
2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.  
3. There is no start input with H3DE-S@ models. Operation starts when the power is turned ON.  
4. There is no instantaneous output with H3DE-M1/-S1 models.  
Operating  
mode  
Timing chart  
ta  
A: ON-delay  
t
t
Basic operation  
Power (A1 and A2)  
Start (B1 and A2)  
(see note)  
Power  
Time-limit contacts: NC  
15 and 16 (25 and 26)  
**  
*
Start  
Time-limit contacts: NO  
(output indicator)  
t
15 and 18 (25 and 28)  
Output  
Instantaneous contacts:  
NC 25 and 26  
*
For power-on operation, impose voltage to the  
Instantaneous contacts:  
NO 25 and 28  
Start input. The Timer starts operating at the  
moment the power is turned on.  
** Start input is invalid while the Timer is in opera-  
tion.  
Power indicator  
ta  
ta  
B:  
Basic operation  
t
t
t
t
t
Flicker OFF  
start  
Power (A1 and A2)  
Power  
Start (B1 and A2)  
(see note)  
**  
*
Output relay: NC 15  
and 16 (25 and 26)  
Start  
t
t
t
t
Output relay: NO  
(output indicator)  
15 and 18 (25 and 28)  
Output  
Instantaneous contacts:  
NC 25 and 26  
*
For power-on operation, impose voltage to the  
Start input. The Timer starts operating at the  
moment the power is turned on.  
Instantaneous contacts:  
NO 25 and 28  
** Start input is invalid while the Timer is in opera-  
tion.  
Power indicator  
ta  
ta  
B2:  
Flicker ON  
start  
t
t
t
t
t
Power (A1 and A2)  
Basic operation  
Start (B1 and A2)  
(see note)  
Power  
Output relay: NC 15  
and 16 (25 and 26)  
**  
*
Start  
Output relay: NO  
(output indicator)  
15 and 18 (25 and 28)  
t
t
t
t
Instantaneous contacts:  
NC 25 and 26  
Output  
*
For power-on operation, impose voltage to the  
Start input. The Timer starts operating at the  
moment the power is turned on.  
Instantaneous contacts:  
NO 25 and 28  
** Start input is invalid while the Timer is in opera-  
tion.  
Power indicator  
C:  
ta  
ta  
t
t
t
t
Signal ON/  
OFF-  
Power (A1 and A2)  
delay  
Start (B1 and A2)  
(see note)  
Basic operation  
Output relay: NC 15  
and 16 (25 and 26)  
Power  
Output relay: NO  
(output indicator)  
15 and 18 (25 and 28)  
*
Start  
Instantaneous contacts:  
NC 25 and 26  
t
t
t
t
Instantaneous contacts:  
NO 25 and 28  
Output  
*
Start input is valid and re-triggerable while the  
Timer is in operation.  
Power indicator  
Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals.  
The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement)  
Solid-state Multi-functional Timer H3DE-M/-S  
B-59  
.
Operating  
mode  
Timing chart  
D:  
ta  
ta  
ta  
t
t
Signal OFF-  
delay  
Power (A1 and A2)  
Basic operation  
Start (B1 and A2)  
(see note)  
Output relay: NC 15  
and 16 (25 and 26)  
Power  
Output relay: NO  
(output indicator)  
15 and 18 (25 and 28)  
*
Start  
Instantaneous contacts:  
NC 25 and 26  
t
Output  
Instantaneous contacts:  
NO 25 and 28  
*
Start input is valid and re-triggerable while the  
Timer is in operation.  
Power indicator  
ta  
ta  
E: Interval  
t
t
t
Basic operation  
Power (A1 and A2)  
Start (B1 and A2)  
(see note)  
Power  
Output relay: NC 15  
and 16 (25 and 26)  
**  
*
Start  
Output relay: NO  
(output indicator)  
15 and 18 (25 and 28)  
t
Output  
Instantaneous contacts:  
NC 25 and 26  
*
For power-on operation, impose voltage to the  
Start input. The Timer starts operating at the  
moment the power is turned on.  
Instantaneous contacts:  
NO 25 and 28  
** Start input is valid and re-triggerable while the  
Timer is in operation.  
Power indicator  
ta  
ta  
G:  
t
t
t
t
Signal ON/  
OFF-  
Power (A1 and A2)  
delay  
Start (B1 and A2)  
(see note)  
Basic operation  
Output relay: NC 15  
and 16 (25 and 26)  
Power  
Output relay: NO  
(output indicator)  
15 and 18 (25 and 28)  
*
t
Start  
Instantaneous contacts:  
NC 25 and 26  
t
t
t
Output  
*
Instantaneous contacts:  
NO 25 and 28  
Start input is valid and re-triggerable while the  
Timer is in operation.  
Power indicator  
ta  
ta  
J:  
t
t
t
One-shot out-  
put  
(ON delay)  
Power (A1 and A2)  
Basic operation  
Start (B1 and A2)  
(see note)  
Power  
Output relay: NC 15  
and 16 (25 and 26)  
**  
*
Approx.  
1+0.6 s  
(fixed)  
Output relay: NO  
(output indicator)  
15 and 18 (25 and 28)  
Approx.  
1+0.6 s  
(fixed)  
Approx.  
1+0.6 s  
(fixed)  
Start  
t
Approx. 1+0.6 s  
(fixed)  
Instantaneous contacts:  
NC 25 and 26  
Output  
*
For power-on operation, impose voltage to the  
Start input. The Timer starts operating at the  
moment the power is turned on.  
Instantaneous contacts:  
NO 25 and 28  
** Start input is valid and re-triggerable while the  
Timer is in operation.  
Power indicator  
Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals.  
The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement).  
B-60  
Solid-state Multi-functional Timer H3DE-M/-S  
Nomenclature  
Nameplate for user use (20  
x 5.4 mm white panel)  
Time scale display window  
Time unit display window  
Time unit selector (select one from  
sec, min, hrs, and 10 h)  
Time scale selector  
(select 0.1 or 1)  
Main dial (for setting a time value)  
Operating mode display window  
Output indicator (orange)  
(Lit while Timer gives output.)  
Operating mode selector  
(select a mode from A, B, C,  
B2, D, E, J, and G for the  
H3DE-M1/-M2, from A, E, J,  
and B2 for the H3DE-S1/S2)  
Power-on indicator (green)  
(Lit while the power is on.)  
(Front View)  
Output Type Selector Switch Settings  
Setting  
Output type  
Time-limit output (terminal numbers 25, 26 and  
28) (default setting)  
Output type selector switch for  
H3DE-M2/-S2 (default setting  
is time-limit output)  
Instantaneous output  
(terminal numbers 21, 22 and 24)  
(Bottom View)  
Solid-state Multi-functional Timer H3DE-M/-S  
B-61  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Terminal block (black)  
H3DE-M/-S  
Surface color: Light gray 5Y7/1 (OMRON)  
Output type selector switch (default setting: Time-limit output)  
Terminal block (black)  
B-62  
Solid-state Multi-functional Timer H3DE-M/-S  
HSoli3d-sDtateETw-inFTimer  
• Operates in flicker-OFF or flicker-ON start mode with one Unit.  
• Independent ON- and OFF-time settings.  
Combinations of long ON- or OFF-time and short OFF- or ON-  
time setting are possible.  
• Long time range from 0.1 s to 12 h for both ON and OFF time  
settings.  
Model Number Structure  
Model Number Legend  
H3DE -  
1
1. F: Twin timers  
Ordering Information  
List of Models  
Operating mode  
Supply voltage  
24 to 230 VAC/VDC  
Model  
Flicker-OFF/Flicker-ON start  
H3DE-F  
Accessories (Order Separately)  
Mounting Track  
50 cm (l) x 7.3 mm (t)  
1 m (l) x 7.3 mm (t)  
1 m (l) x 16 mm (t)  
PFP-M  
PFP-50N  
PFP-100N  
PFP-100N2  
End Plate  
Spacer  
PFP-S  
Solid-state Twin Timer H3DE-F  
B-63  
Specifications  
General  
Item  
H3DE-F  
Operating mode  
Flicker-OFF/Flicker-ON start  
Operating/Reset method  
Terminal block  
Time-limit operation/Time-limit reset or self-reset  
Clamps two 2.5 mm2 max. bar terminals without sleeves  
Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.}  
Output type  
Relay: SPDT  
Mounting method  
Attachment  
DIN track mounting (see note)  
Nameplate  
Approved standards  
UL508, CSA 22.2 No.14  
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P 100  
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)  
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.  
Time Ranges  
Time scale display  
Time unit display  
(see note 1)  
sec  
10 s  
min  
0.1 to 1.2 min  
1 to 12 min  
hrs  
x 0.1  
x 1  
0.1 to 1.2 s  
1 to 12 s  
1 to 12 s  
0.1 to 1.2 h  
1 to 12 h  
10 to 120 s  
Note: 1. Time scale display is applied commonly for ON and OFF time.  
2. When the main dial is set to “0” for all settings, the output will operate instantaneously.  
Ratings  
Rated supply voltage (see note)  
24 to 230 VAC/VDC (50/60 Hz)  
85% to 110% of rated supply voltage  
Minimum power-off time: 0.1 s  
2.4 VAC/DC max.  
Operating voltage range  
Power reset  
Reset voltage  
Power consumption  
AC: Approx. 3.1 VA (1.8 W) at 230 VAC  
DC: Approx. 0.8 W at 24 VDC  
Control output  
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)  
5 A at 30 VDC with resistive load (cosφ = 1)  
Ambient temperature  
Operating: 10°C to 55°C (with no icing)  
Storage:  
25°C to 65°C (with no icing)  
Ambient humidity  
Operating: 35% to 85%  
Note: DC ripple rate: 20% max.  
B-64  
Solid-state Twin Timer H3DE-F  
Characteristics  
Accuracy of operating time  
1% max. of FS ( 1% 10 ms max. at 1.2-s range)  
Setting error  
10% 0.05 s max. of FS  
Influence of voltage  
Influence of temperature  
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)  
2% max. of FS ( 2% 10 ms max. at 1.2-s range)  
Insulation resistance  
Dielectric strength  
100 Mmin. at 500 VDC  
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1  
min.  
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.  
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.  
Impulse withstand voltage 3 kV (between power supply terminals)  
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)  
Noise immunity  
Static immunity  
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) 1.5 kV  
Malfunction: 4 kV  
Destruction: 8 kV  
Vibration resistance  
Shock resistance  
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz  
Destruction: 0.75-mm single amplitude at 10 to 55 Hz  
Malfunction: 100 m/s2  
Destruction: 1,000 m/s2  
Life expectancy  
EMC  
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)  
Electrical:  
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)  
(EMI)  
EN61812-1  
Emission Enclosure:  
Emission AC Mains:  
Harmonic Current:  
Voltage Fluctuation and Flickering:  
(EMS)  
EN55011 Group 1 class B  
EN55011 Group 1 class B  
EN61000-3-2  
EN61000-3-3  
EN61812-1  
Immunity ESD:  
EN61000-4-2: 6 kV contact discharge (level 3)  
8 kV air discharge (level 3)  
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)  
Immunity Burst:  
EN61000-4-4: 2 kV power port and output port (level 3)  
1 kV control port with capacitive clamp (level 3)  
EN61000-4-5: 2 kV common mode (level 3)  
1 kV differential mode (level 3)  
Immunity Surge:  
Degree of protection  
Weight  
IP30 (IP20 for terminal block)  
Approx. 110 g  
Note: For reference:  
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).  
A maximum current of 0.1 A can be switched if L/R is 7 ms.  
In both cases, a life of 100,000 operations can be expected.  
The minimum applicable load is 10 mA at 5 VDC (failure level: P).  
Solid-state Twin Timer H3DE-F  
B-65  
Connections  
Block Diagram  
ON  
OFF  
indicator indicator  
ON/OFF start  
selector  
AC (DC)  
input  
Indicator  
circuit  
Time unit  
selector  
ROM  
RAM  
Clock  
One-chip microcomputer  
Power  
supply  
circuit  
Output  
circuit  
I/O Function  
Inputs  
---  
Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial.  
Outputs  
Control output  
Terminal Arrangement  
(DIN notation)  
15  
A1  
A2  
1618  
Note: DC supply voltage does not require the designation of polarity.  
B-66  
Solid-state Twin Timer H3DE-F  
Operation  
Basic Operation  
Time Unit Selection  
Time Scale Selection  
The time unit display window for output ON is located on the upper-  
right side of the front panel above the corresponding time unit selec-  
tor.  
The time scale selector on the upper-left side of the front panel can  
be set to 0.1 or 1 as a magnification coefficient.  
The time unit display window for output OFF is located on the lower-  
right side of the front panel below the corresponding time unit selec-  
tor.  
According to the setting of each time unit selector, “sec” for seconds,  
“10s” for 10 seconds, “min” for minutes, or “hrs” for hours will appear  
in the corresponding time unit display window.  
Time scale display window  
Time scale selector  
ON-time setting  
dial  
ON-time unit display window  
ON-time unit selector (select  
one from sec, 10s, min, or hrs)  
OFF-time setting dial  
Time Setting  
Use the ON/OFF-time setting dial to set the ON/OFF time.  
OFF-time unit selector (select  
one from sec, 10s, min, or hrs)  
OFF-time unit display window  
Timing Charts  
Operating  
mode  
Timing chart  
Flicker-OFF  
start  
0.1 s min.  
ON  
OFF  
Power (A1 and A2)  
Output relay: NO  
15 and 18  
(ON indicator)  
ON  
OFF  
Output relay: NC  
15 and 16  
ON  
OFF  
ON  
OFF  
OFF indicator  
t
t
ON: ON set time  
OFF: OFF set time  
Flicker-ON  
start  
0.1 s min.  
ON  
OFF  
Power (A1 and A2)  
Output relay:  
NO 15 and 18  
(ON indicator)  
ON  
OFF  
Output relay: NC  
15 and 16  
ON  
OFF  
ON  
OFF  
OFF indicator  
t
ON: ON set time  
OFF: OFF set time  
t
Note: 1. The reset time requires a minimum of 0.1 s.  
2. When power is supplied in flicker-ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance  
of the Timer.  
Solid-state Twin Timer H3DE-F  
B-67  
Nomenclature  
Nameplate for user use (20 x 5.4 mm white panel)  
ON-time unit display window  
Time scale display window  
Time unit selector  
(select one from s, 10s, min, or h for output ON)  
Time scale selector  
(select 0.1 or 1)  
Output ON indicator (orange)  
ON-time setting dial  
OFF-time setting dial  
Output OFF indicator (green)  
OFF-time unit selector  
(select one from s, 10s, min, or h)  
OFF-time unit display window  
(Front View)  
ON/OFF Start Selector Switch Settings  
Setting Operating mode  
Flicker-ON start  
ON/OFF start selector  
(default is flicker-OFF start)  
Flicker-OFF start  
(Bottom View)  
Dimensions  
Terminal block (black)  
H3DE-F  
Surface color:  
Light gray 5Y7/1  
(OMRON)  
Terminal block (black)  
B-68  
Solid-state Twin Timer H3DE-F  
HSoli3d-sDtateESta-r-Gdelta Timer  
• A wide star-time range (up to 120 seconds) and star-delta trans-  
fer time range (up to 0.5 seconds)  
Model Number Structure  
Model Number Legend  
H3DE -  
1
1. G: Star-delta timer  
Ordering Information  
List of Models  
Supply voltage  
Model  
24 to 230 VAC/VDC  
H3DE-G  
Accessories (Order Separately)  
Mounting Track  
50 cm (l) x 7.3 mm (t)  
1 m (l) x 7.3 mm (t)  
1 m (l) x 16 mm (t)  
PFP-M  
PFP-50N  
PFP-100N  
PFP-100N2  
End Plate  
Spacer  
PFP-S  
Solid-state Star-delta Timer H3DE-G  
B-69  
Specifications  
General  
Item  
H3DE-G  
Operating mode  
Star-delta operation  
Operating/Reset method  
Terminal block  
Time-limit operation/Self-reset  
Clamps two 2.5 mm2 max. bar terminals without sleeves  
Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.}  
Output type  
(Star operation circuit) Relay: SPDT  
(Delta operation circuit) Relay: SPDT  
Mounting method  
Attachment  
DIN track mounting (see note)  
Nameplate  
Approved standards  
UL508, CSA 22.2 No.14  
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100  
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)  
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.  
Time Ranges  
Time scale display  
x 1  
x 10  
Star operation time ranges  
1 to 12 s  
10 to 120 s  
Star-delta transfer time  
Programmable at 0.05 s, 0.1 s, 0.25 s or 0.5 s  
Ratings  
Rated supply voltage (see note)  
Operating voltage range  
Power reset  
24 to 230 VAC/VDC (50/60 Hz)  
85% to 110% of rated supply voltage  
Minimum power-off time: 0.5 s  
24 VAC/DC max.  
Reset voltage  
Power consumption  
AC: Approx. 3 VA (1.8 W) at 230 VAC  
DC: Approx. 0.8 W at 24 VDC  
Control output  
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)  
5 A at 30 VDC with resistive load (cosφ = 1)  
Ambient temperature  
Operating: 10°C to 55°C (with no icing)  
Storage:  
25°C to 65°C (with no icing)  
Ambient humidity  
Operating: 35% to 85%  
Note: DC ripple rate: 20% max.  
B-70  
Solid-state Star-delta Timer H3DE-G  
Characteristics  
Accuracy of operating time  
1% max. of FS  
Setting error  
10% 0.05 s max. of FS  
(25% FS + 5 ms) max.  
Total tolerance of transfer  
time  
Influence of voltage  
Influence of temperature  
Insulation resistance  
Dielectric strength  
0.5% max. of FS  
2% max. of FS  
100 Mmin. at 500 VDC  
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1  
min.  
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.  
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.  
Impulse withstand voltage 3 kV (between power supply terminals)  
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)  
Noise immunity  
Static immunity  
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) 1.5 kV  
Malfunction: 4 kV  
Destruction: 8 kV  
Vibration resistance  
Shock resistance  
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz  
Destruction: 0.75-mm single amplitude at 10 to 55 Hz  
Malfunction: 100 m/s2  
Destruction: 1,000 m/s2  
Life expectancy  
EMC  
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)  
Electrical:  
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)  
(EMI)  
EN61812-1  
Emission Enclosure:  
Emission AC Mains:  
Harmonic Current:  
Voltage Fluctuation and Flickering:  
(EMS)  
EN55011 Group 1 class B  
EN55011 Group 1 class B  
EN61000-3-2  
EN61000-3-3  
EN61812-1  
Immunity ESD:  
EN61000-4-2: 6 kV contact discharge (level 3)  
8 kV air discharge (level 3)  
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)  
Immunity Burst:  
EN61000-4-4: 2 kV power port and output port (level 3)  
1 kV control port with capacitive clamp (level 3)  
EN61000-4-5: 2 kV common mode (level 3)  
1 kV differential mode (level 3)  
Immunity Surge:  
Degree of protection  
Weight  
IP30 (IP20 for terminal block)  
Approx. 120 g  
Note: For reference:  
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).  
A maximum current of 0.1 A can be switched if L/R is 7 ms.  
In both cases, a life of 100,000 operations can be expected.  
The minimum applicable load is 10 mA at 5 VDC (failure level: P).  
Solid-state Star-delta Timer H3DE-G  
B-71  
Connections  
Block Diagram  
Star  
Star-delta  
transfer  
time  
AC (DC) input  
operation  
time scale  
selector  
selection  
Star-delta  
transfer  
time  
counting  
circuit  
Star opera-  
tion time  
oscillation  
circuit  
Star opera-  
tion time  
counting  
circuit  
Star-delta  
transfer  
time oscilla-  
tion circuit  
Power  
supply  
circuit  
Star operation  
Delta operation  
Output  
circuit  
Indicator  
circuit  
Star operation Delta operation  
indicator  
indicator  
I/O Functions  
Inputs  
---  
Outputs  
Control output  
Star output is turned OFF when the dial set value is reached and delta output is ON after  
the preset transfer time elapses  
Terminal Arrangement  
25  
25  
15  
18  
16 28  
26  
28  
26  
(DIN notation)  
15  
25  
A1  
A2  
1618 2628  
Note: DC supply voltage does not require the designation of polarity.  
B-72  
Solid-state Star-delta Timer H3DE-G  
Operation  
Basic Operation  
Time Unit Setting  
Time Scale Selection  
The star-delta transfer time is set to 0.05, 0.1, 0.25 or 0.5 with the  
star-delta transfer time selector on the lower-right side of the front  
panel and the set value appears in the star-delta transfer time display  
window below the selector.  
The star operation time scale selector on the upper-left side of the  
front panel can be set to 1 or 10 as a magnification.  
Star operation time  
scale display window  
Star operation time  
scale selector  
Time setting dial  
Star-delta transfer time selector  
Star-delta transfer time display  
window  
Time Setting  
The operation time of the Timer is set with the time setting dial.  
Timing Charts  
0.5 s  
ON  
Power (A1 and A2)  
OFF  
Star contact  
15 and 18  
(star indicator)  
ON  
OFF  
Star contact  
15 and 16  
ON  
OFF  
Delta contact  
25 and 28  
(delta indicator)  
ON  
OFF  
Delta contact  
25 and 26  
ON  
OFF  
t
1
: Star operation time setting  
: Star-delta transfer time  
t2  
Note: The reset time requires a maximum of 0.5 s.  
Nomenclature  
Nameplate for user use (20 x 5.4 mm white panel)  
Time setting dial (for setting star operation time)  
Time scale display window  
Star operation time scale selector  
(select 1 or 10)  
Star operation indicator (green)  
Delta operation indicator (orange)  
Star-delta transfer time selector  
Star-delta transfer time display window  
(Front View)  
Solid-state Star-delta Timer H3DE-G  
B-73  
Dimensions  
Terminal block (black)  
H3DE-G  
Surface color:  
Light gray 5Y7/1  
(OMRON)  
Terminal block (black)  
B-74  
Solid-state Star-delta Timer H3DE-G  
HSoli3d-sDtateEPow-eHr OFF-delay Timer  
Two delay-time models available.  
0.1 to 12 seconds (S Series)  
1 to 120 seconds (L Series)  
• Covers wide range of supply voltage.  
Model Number Structure  
Model Number Legend  
H3DE -  
1
1. H: Power OFF-delay timer  
Ordering Information  
List of Models  
Supply voltage  
Model  
S Series (time range: 0.1 to 12 s)  
H3DE-H  
L Series (time range: 1 to 120 s)  
H3DE-H  
100 to 120 VAC  
200 to 230 VAC  
24 VAC/VDC  
48 VAC/VDC  
Note: Specify both the model number and supply voltage when ordering.  
Example: H3DE-H 24 VAC/DC S  
Time span code  
Supply voltage  
Accessories (Order Separately)  
Mounting Track  
50 cm (l) x 7.3 mm (t)  
1 m (l) x 7.3 mm (t)  
1 m (l) x 16 mm (t)  
PFP-M  
PFP-50N  
PFP-100N  
PFP-100N2  
End Plate  
Spacer  
PFP-S  
Solid-state Power OFF-delay Timer H3DE-H  
B-75  
Specifications  
General  
Item  
H3DE-H  
Operating mode  
Power OFF-delay  
Operating/Reset method  
Terminal block  
Instantaneous operation/Time-limit reset  
Clamps Two 2.5 mm2 max. bar terminals without sleeves  
Terminal screw tightening torque 0.98 N·m max. {approx. 10 kgf·cm max.}  
Output type  
Relay: SPDT  
Mounting method  
Attachment  
DIN track mounting (see note)  
Nameplate  
Approved standards  
UL508, CSA 22.2 No.14  
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100  
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)  
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.  
Time Ranges  
Time scale display  
Time ranges  
Min. power ON time  
0.1 s minimum  
S series  
L series  
x 0.1 s  
x 1 s  
0.1 to 1.2 s  
1 to 12 s  
x 1 s  
1 to 12 s  
0.3 s minimum  
x 10 s  
10 to 120 s  
Note: The Timer will not operate if the specified power-on time is not kept. Be sure to supply power for at least the period specified.  
Ratings  
Rated supply voltage (see note)  
100 to 120 VAC (50/60 Hz)  
200 to 230 VAC (50/60 Hz)  
24 VAC/VDC (50/60 Hz)  
48 VAC/VDC (50/60 Hz)  
Operating voltage range  
Power consumption  
85% to 110% of rated supply voltage  
24 VAC/VDC Type  
48 VAC/VDC Type  
AC: Approx. 0.3 VA (0.2 W) at 24 VAC  
DC: Approx. 0.2 W at 24 VDC  
AC: Approx. 0.5 VA (0.5 W) at 48 VAC  
DC: Approx. 0.5 W at 48 VDC  
100 to 120 VAC Type  
200 to 230 VAC Type  
AC: Approx. 0.8 VA (0.7 W) at 120 VAC  
AC: Approx. 1.6 VA (1.0 W) at 230 VAC  
Control output  
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)  
5 A at 30 VDC with resistive load (cosφ = 1)  
Ambient temperature  
Ambient humidity  
Operating: 10°C to 55°C (with no icing)  
Storage:  
25°C to 65°C (with no icing)  
Operating: 35% to 85%  
Note: The ripple in DC power supply must be 20% max. A single-phase, full-wave rectifying power supply can be connected if the ripple output of  
the power supply is a maximum of 20% of the whole output.  
B-76  
Solid-state Power OFF-delay Timer H3DE-H  
Characteristics  
Accuracy of operating time  
1% max. of FS ( 1% 10 ms max. at 1.2-s range)  
Setting error  
10% 0.05 s max. of FS  
Influence of voltage  
Influence of temperature  
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)  
2% max. of FS ( 2% 10 ms max. at 1.2-s range)  
Insulation resistance  
Dielectric strength  
100 Mmin. at 500 VDC  
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1  
min.  
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.  
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.  
Impulse withstand voltage 3 kV (or 1 kV for 24/48 VAC/VDC models) (between power supply terminals)  
4.5 kV (or 1.5 kV for 24/48 VAC/VDC models) (between current-carrying metal parts and exposed non-current-  
carrying metal parts)  
Noise immunity  
Static immunity  
Vibration resistance  
Shock resistance  
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) 1.5 kV (between power  
supply terminals)  
Malfunction: 4 kV  
Destruction: 8 kV  
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz  
Destruction: 0.75-mm single amplitude at 10 to 55 Hz  
Malfunction: 100 m/s2  
Destruction: 1,000 m/s2  
Life expectancy  
EMC  
Mechanical: 10 million operations min. (under no load at 1,200 operations/h)  
Electrical:  
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h)  
(EMI)  
EN61812-1  
Emission Enclosure:  
Emission AC Mains:  
Harmonic Current:  
Voltage Fluctuation and Flickering:  
(EMS)  
EN55011 Group 1 class A  
EN55011 Group 1 class A  
EN61000-3-2  
EN61000-3-3  
EN61812-1  
Immunity ESD:  
EN61000-4-2:6 kV contact discharge (level 3)  
8 kV air discharge (level 3)  
Immunity RF-interference from AM Radio Waves: EN61000-4-3:10 V/m (80 MHz to 1 GHz) (level 3)  
Immunity Burst:  
EN61000-4-4:2 kV power port and output port (level 3)  
1 kV control port with capacitive clamp (level 3)  
EN61000-4-5:2 kV common mode (level 3)  
1 kV differential mode (level 3)  
Immunity Surge:  
Degree of protection  
Weight  
IP30 (IP20 for terminal block)  
Approx. 120 g  
Note: For reference:  
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).  
A maximum current of 0.1 A can be switched if L/R is 7 ms.  
In both cases, a life of 100,000 operations can be expected.  
The minimum applicable load is 100 mA at 5 VDC (failure level: P).  
Solid-state Power OFF-delay Timer H3DE-H  
B-77  
Connections  
Block Diagram  
Indicator  
circuit  
Time scale  
selector  
AC (DC) input  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output  
circuit  
Power failure  
detection circuit  
I/O Functions  
Inputs  
---  
Outputs  
Control output The Timer operates instantaneously when the Timer is turned ON. The Timer is in counting operation  
after the Timer is turned OFF and the output of the Timer is turned OFF when the preset time elapses.  
Terminal Arrangement  
(DIN notation)  
15  
A1  
A2  
1618  
Note: DC supply voltage does not require the designation of polarity.  
B-78  
Solid-state Power OFF-delay Timer H3DE-H  
Operation  
Basic Operation  
Time Scale Selection  
Time Setting  
The time scale selector on the upper left-hand side of the front panel  
of the S Series can be set to 0.1 or 1 and that of the L Series can be  
set to 1 or 10 as magnification coefficients.  
The operating time of the Timer is set with the time setting dial.  
Time scale display window  
Time scale selector  
Time  
setting  
dial  
Timing Charts  
Power supply  
(A and A  
ON  
OFF  
1
2)  
ON  
OFF  
Output relay: NC  
15 and 16  
ON  
OFF  
Output relay: NO  
15 and 18  
ON  
OFF  
Power indicator  
t: Set time  
Rt: Minimum power-on time (S-series: 0.1 s min.; L-series: 0.3 s min.)  
(The output may never turn ON if this time or more is not ensured.)  
Nomenclature  
Nameplate for user use  
(20 x 5.4 mm white panel)  
Time scale  
display window  
Time scale selector  
S Series: Set to 0.1 or 1  
L Series: Set to 1 or 10  
Time setting dial (for setting  
power OFF-delay time)  
Power indicator (green)  
Lit when the Timer is turned ON.  
(Front View)  
Solid-state Power OFF-delay Timer H3DE-H  
B-79  
Dimensions  
Terminal block (black)  
H3DE-H  
Surface color:  
Light gray 5Y7/1  
(OMRON)  
Terminal block (black)  
B-80  
Solid-state Power OFF-delay Timer H3DE-H  
Accessories (Order Separately) (Common)  
Note: The undermentioned is common for all H3DE models.  
Note: All units are in millimeters unless otherwise indicated.  
Dimensions  
Mounting Track  
PFP-100N, PFP-50N  
PFP-100N2  
16  
7.3 0.15  
35 0.3  
4.5  
4.5  
29.2  
1.5  
27  
35 0.3  
24  
27 0.15  
1
15 25  
25  
25  
25 15  
15 25  
25  
25  
25  
*
1
10  
10  
10  
10  
L
L
L: Length  
1 m PFP-100N  
50 cm PFP-50N  
1 m PFP-100N2  
End Plate  
PFP-M  
Spacer  
PFP-S  
16  
12  
10  
6.2  
5
1.8  
1
35.5 35.3  
34.8  
50  
44.3  
1.8  
11.5  
1.3  
4.8  
M4 x 8  
pan head  
screw  
10  
16.5  
Solid-state Timer H3DE (Common)  
B-81  
Precautions (Common)  
Note: The undermentioned is common for all H3DE models.  
Changing of Setting  
!Caution  
Power Supplies  
The H3DE Series is provided with a transformerless power supply  
system. An electric shock may be received if the input terminal or the  
output type selector switch is touched while power is being supplied.  
Do not change the time unit, time scale, operating mode, or output  
type selector switch while the Timer is in operation or malfunction  
could result.  
Use the bar terminal for wiring the H3DE. Using a stranded-wire ter-  
minal may cause a short-circuit due to a stray wire entering into the  
Timer.  
Mounting and Dismounting  
The H3DE should be mounted as horizontally as possible.  
Both AC and DC power supplies can be connected to the power  
input terminals without regarding polarity.  
When mounting the H3DE on a socket mounting track, hook portion  
(A) of the Timer to an edge of the track first, and then depress the  
Timer in the direction of (B).  
With the H3DE only, a DC power supply must be connected to the  
power input terminals as designated according to the polarity of the  
terminals.  
A DC power supply can be connected if its ripple factor is 20% or  
less and the mean voltage is within the rated operating voltage range  
of the Timer.  
(A)  
Connect the power supply voltage through a relay or switch in such a  
way that the voltage reaches a fixed value at once or the Timer may  
not be reset or a timer error could result.  
For the power supply of an input device, use an isolating transformer,  
of which the primary and secondary windings are mutually isolated  
and the secondary winding is not grounded.  
(B)  
A1  
When dismounting the H3DE, pull out portion (C) with a flat-blade  
screwdriver and remove the Timer from the mounting track.  
B1  
H3DE  
Power supply  
Start  
input  
A2  
Circuit  
Isolation transformer is required.  
The H3DE-H has a large inrush current; provide sufficient power  
supply capacity. If the power supply capacity is too small, there may  
be delays in turning ON the output.  
30 mm min.  
Rail stopper  
(C)  
Installation  
The H3DE can be mounted and dismounted with ease if a distance  
of 30 mm or more is kept between the H3DE and the top surface of  
other equipment located below the H3DE.  
If the load current is continuously being supplied to the Timer for a  
long period of time, be sure to provide the mounting clearance as  
shown in the figure below. If used under the conditions other than  
those specified below, the life of internal components may be short-  
ened due to an excessive rise in the internal temperature.  
H3DE  
H3DE  
H3DE  
DIN track  
t
t
t: Mounting clearance (mm)  
B-82  
Solid-state Timer H3DE (Common)  
Switching Current vs. Ambient Temperature  
(When Mounting Two or More H3DE Units  
Side-by-Side)  
Contact or transistor for  
external input signal  
A1  
B1  
H3DE  
Incorrect  
Power supply  
Mounting clearance:  
50 mm  
70  
Mounting  
clearance: 10 mm  
60  
A2  
A1  
Short-circuit  
current  
Maximum range of  
operating ambient  
temperature  
50  
40  
Mounting  
clearance: 5 mm  
B1  
H3DE  
Mounting  
clearance: 0 mm  
30  
20  
A2  
Contact or transistor for  
external input signal  
A1  
0
1
2
3
4
5
Load current (A)  
B1  
H3DE  
Power supply  
Input/Output  
Correct  
A2  
A1  
Relationship between Input and Power  
Supply Circuits  
Short-circuit  
current  
B1  
H3DE  
B1  
A1  
AC/DC  
power  
supply  
Power supply  
circuit  
Input circuit  
A2  
The H3DE Series is provided with a transformerless power supply  
system.  
A2  
Since the input circuit and the power supply circuit are configured  
independently, the input circuit can be turned on or off irrespective of  
the on/off state of the power supply.  
It must be noted that a voltage equivalent to the power supply voltage  
is applied to the input circuit.  
Input Wires  
The input wires must be as short as possible. If the floating capacity  
of wires exceeds 2,000 pF (approx. 17 m for cables with 120 pF/m),  
the operation will be affected. Pay particular attention when using  
shielded cables.  
When connecting a relay or a transistor as an external signal input  
device, pay attention to the following points to prevent short-circuiting  
due to a sneak current to the transformerless power supply.  
Wiring (H3DE-H)  
If a relay or transistor is connected to two or more Timers, the input  
terminals of those Timers must be wired properly so that they will not  
be different in phase or the terminals will be short-circuited to one  
another (refer to the figures below).  
The H3DE has a high impedance circuit. Therefore, the H3DE may  
not be reset if the H3DE is influenced by inductive voltage. In order to  
eliminate any influence of inductive voltage, the wires connected to  
the H3DE must be as short as possible and should not be installed  
alongside power lines. If the H3DE is influenced by inductive voltage  
that is 30% or more of the rated voltage, connect a CR filter with a  
capacitance of approximately 0.1 µF and a resistance of approxi-  
mately 120 or a bleeder resistor between the power supply termi-  
nals. If there is any residual voltage due to current leakage, connect  
a bleeder resistor between the power supply terminals.  
Solid-state Timer H3DE (Common)  
B-83  
Operation (H3DE-H)  
An interval of 3 s minimum is required to turn on the H3DE after the  
H3DE is turned off. If the H3DE is turned on and off repeatedly with  
an interval of shorter than 3 s, the internal parts of the H3DE may  
deteriorate and the H3DE may malfunction.  
Environment  
When using the Timer in an area with excess electronic noise, sepa-  
rate the Timer, wiring, and the equipment which generates the input  
signals as far as possible from the noise sources. It is also recom-  
mended to shield the input signal wiring to prevent electronic interfer-  
ence.  
3 s min.  
Organic solvents (such as paint thinner), as well as very acidic or  
basic solutions can damage the outer casing of the Timer.  
Power  
Do not use the Timer in places where it is exposed to dust, corrosive  
gas, or direct sunlight.  
Output  
state 1  
When storing the Timer, make sure that the ambient temperature  
and humidity are within the rated values. Leave the Timer at room  
temperature for at least three hours before using the Timer if it has  
been stored at an ambient temperature of –10°C or below.  
Output  
state 2  
If it is required that the output be turned on repeatedly with an inter-  
val of shorter than 3 s, consider use of the H3DE-M2/-M1 in mode D  
(signal OFF-delay).  
Others  
If the Timer is mounted on a control board, dismount the Timer from  
the control board or short-circuit the circuitry of the power board  
before carrying out a voltage withstand test between the electric cir-  
cuitry and non current-carrying metal part of the Timer, in order to  
prevent the internal circuitry of the Timer from damage.  
Precautions for EN61812-1  
Conformance  
The H3DE as a built-in timer conforms to EN61812-1 provided that  
the following conditions are satisfied:  
It must be noted that although the electrical life expectancy of the  
H3DE Timer shown in the catalog is the same as the H3DR Timer  
shown in the catalog, the actual performance varies because the  
built-in relays are different as follows:  
The output section of the H3DE is provided only with basic isolation.  
To ensure reinforced isolation required by the EN61812-1, provide  
supplementary basic isolation on the load side connected to the out-  
put.  
Built-in relay for the H3DR: G2R; 100,000 operations min.  
(10 A for SPDT and 5 A for DPDT at  
250 VAC, resistive load at  
The H3DE itself is designed according to the following:  
1,800 operations/h.)  
Overvoltage category III  
Pollution degree 2  
Built-in relay for the H3DE: G6RN; 50,000 operations min.  
(8 A at 250 VAC, resistive load at  
On the above basis:  
360 operations/h.)  
Operation parts on the front and bottom: Reinforced isolation  
With clearance of 5.5 mm and creepage distance of 5.5 mm at  
230 VAC  
Output: Basic isolation  
With clearance of 3 mm and creepage distance of 3 mm at  
230 VAC  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
Cat. No. L092-E1-05  
B-84  
Solid-state Timer H3DE (Common)  

相关型号:

H3DE-G

Solid-state Timer
OMRON

H3DE-H

Solid-state Timer
OMRON

H3DE-M

Solid-state Timer
OMRON

H3DE-S

Solid-state Timer
OMRON

H3DK

Solid-state Timers
OMRON

H3DK-F

Solid-state Timers
OMRON

H3DK-G

Solid-state Timers
OMRON

H3DK-H

Solid-state Timers
OMRON

H3DK-M

Solid-state Timers
OMRON

H3DK-S

Solid-state Timers
OMRON

H3DKFACDC24240

Solid-state Timers
OMRON

H3DKH-1036M

IDC CBL - HHKR10H/AE10M/HHPK10H
ASSMANN