H5AN-4D-DC48 [OMRON]

Analog Circuit;
H5AN-4D-DC48
型号: H5AN-4D-DC48
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Analog Circuit

文件: 总10页 (文件大小:144K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Multifunction Digital Timer  
H5AN  
Quartz Timer Offers Eight Time  
Ranges, Seven Output Operations  
Field-selectable time ranges from 0.01  
second to 9999 hours  
Selectable elapsed time (UP) and  
time remaining (DOWN) display  
Contact and solid-state outputs available  
simultaneously  
ON-delay with sustained and adjustable  
one-shot outputs, with and without  
continued timing  
Built-in DC power supply for input devices  
Easy-to-read 8 mm-high LED display  
10-year battery memory back-up available  
Draw-out construction allows setting,  
servicing without disconnecting wiring  
Panel mounting hardware included  
Ordering Information  
TIMERS  
Add the supply voltage to the part number when you order. For example, H5AN-4DM-AC100-240.  
Timing functions  
Contact type  
ON-delay and ON-delay with one-shot  
SPDT relay and open collector transistor outputs, both available simultaneously  
14 terminal screws on rear of case  
Terminal form  
DC power supply for  
external components  
Memory back-up  
Provided  
Provided  
Not provided  
Provided, 10-year built-in battery  
H5AN-4DM  
Part number  
H5AN-4D  
Supply  
voltage  
AC  
DC  
24 V or 100 to 240 V; 50/60 Hz  
12 to 24 V, 48 V or 100 V  
24 V or 100 to 240 V; 50/60 Hz  
12 to 24 V  
REPLACEMENT PARTS  
Description  
Part number  
Plastic front cover  
H5AN COVER 0377762-0  
Y92H-5  
Mounting bracket (one pair supplied with each timer); order two  
1
H5AN  
H5AN  
Specifications  
Part number  
H5AN-4D  
H5AN-4DM  
Supply  
voltage  
AC  
DC  
24 V or 100 to 240 V; 50/60 Hz  
24 V or 100 to 240 V; 50/60 Hz  
12 to 24 V  
(permissible ripple factor: 20% max.)  
12 to 24 V, 48 V or 100 V  
(permissible ripple factor: 20% max.)  
Operating voltage  
85 to 100% of rated voltage  
10 VA at 240 VAC, 50 Hz  
5 W at 24 VDC  
AC  
DC  
Power  
consumption  
Internal power supply  
for external components  
Timing functions  
12 VDC ±10%, 80 mA  
(permissible ripple factor: 5% max.)  
ON-delay and ON-delay with one-slot  
No-voltage  
Reset and Gate inputs  
Type  
Time limit  
SPDT relay and open collector solid-state output  
Control  
output  
Instantaneous  
Max. load  
Min. load  
3 A, 250 VAC (p.f. = 1) for relay; 100 mA max., 30 VDC for open collector output  
10 mA, 5 VDC  
Repeat accuracy  
Setting error  
Resetting system  
Resetting time  
Indicators  
±0.01% ±0.05 sec max. (power-OFF start); ±0.005% ±0.03 sec max. (reset start)  
See "Repeat Accuracy"  
Power-OFF, manual or external  
Manual or external  
Power-OFF: 0.5 sec min.; External: 0.02 sec signal minimum  
Time Up (red LED), Reset Input (red LED); 8 mm LED numeric display  
Materials  
Plastic  
Mounting  
Panel; two mounting brackets included  
Back-mounted screw terminals  
360 g (12.7 oz.)  
Connections  
Weight  
Approvals  
UL/CSA/SEV  
Operating ambient temperature  
Humidity  
-10° to 55°C (14° to 131°F)  
35 to 85% RH  
Vibration Mechanical durability  
Malfunction durability  
10 to 55 Hz; 0.75 mm (0.03 in) double amplitude  
10 to 55 Hz; 0.5 mm (0.02 in) double amplitude  
30 G  
Shock  
Mechanical durability  
Malfunction durability  
10 G  
Variation due to voltage change  
Variation due to temperature change  
Insulation resistance  
See "Repeat Accuracy"  
See "Repeat Accuracy"  
100 Mmin. at 500 VDC  
Dielectric strength  
2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminals and non-current-  
carrying metal parts  
750 VAC, 50/60 Hz for 1 minute between non-continuous contacts  
Service life  
Mechanical  
Electrical  
10 million operations minimum  
100,000 operations minimum at maximum rating  
2
H5AN  
H5AN  
Engineering Data  
ELECTRICAL SERVICE LIFE  
Timing Charts  
ELAPSED TIME (UP) DISPLAY  
ON  
OFF  
Power  
1 - 2  
8 - 9  
ON  
OFF  
Reset  
input  
Interruption  
ON  
OFF  
Gate  
input  
8 - 10  
Time setting  
Digital display  
(See note)  
(See note)  
ON  
OFF  
Control Relay 4 - 5, 4 - 6  
output Solid-state 12-13-14  
ON  
OFF  
Time up indicator  
ON  
OFF  
Reset input indicator  
NOTE: After the set time has elapsed, operation continues according to the mode selected.  
TIME REMAINING (DOWN) DISPLAY  
ON  
OFF  
Power  
1 - 2  
ON  
OFF  
Reset  
input  
8 - 9  
Interruption  
ON  
OFF  
Gate  
input  
8 - 10  
Time setting  
Digital display  
(See note)  
(See note)  
ON  
OFF  
Control Relay 4 - 5, 4 - 6  
output Solid-state 12-13-14  
ON  
OFF  
Time up indicator  
ON  
OFF  
Reset input indicator  
NOTE: After the set time has elapsed, operation continues according to the mode selected.  
3
H5AN  
H5AN  
OPERATION MODES  
Mode  
Elapsed time (UP) display  
Time remaining (DOWN) display  
N
Reset  
Reset  
Sustained  
output  
Set value  
Digital display  
Set value  
Digital display  
Control outpu
Control output  
The display decrements from the preset to zero. When  
zero is reached, the output is energized. Zeros are  
displayed until the timer is reset.  
The display increments from zero to the preset. When  
the preset is reached, the output is energized. The  
preset is display until the timer is reset.  
F
Reset  
Reset  
Sustained  
Output  
Set value  
Digital display  
Set value  
Digital display  
Control output  
Control output  
The display increments from zero to the preset. When  
the preset is reached, the output is energized. The  
display will continue to increment until the timer is reset.  
The display decrements from the preset to zero. When  
zero is reached, the output is energized. The display  
will continue to decrement until the timer is reset.  
C
Reset  
Reset  
One-shot  
Output  
Set value  
Digital displa
Set value  
Digital display  
Control outp
Control outpu
The display increments from zero to the preset. When  
the preset is reached, the timer restarts its timing from  
zero and energizes a one-shot output. The cycle is  
repeated until the timer is reset.  
The display decrements from the preset to zero. When  
zero is reached, the timer restarts its timing from the  
preset and energizes a one-shot output. The cycle is  
repeated until the timer is reset.  
R
Reset  
Reset  
One-shot  
Output  
Set value  
Digital display  
Set value  
Digital display  
Control output  
Control outpu
The display increments from zero to the preset. When  
the preset is reached, the output is energized for the  
one-shot time. Timing from zero is restarted at the  
trailing edge of the output. The cycle is repeated until  
the timer is reset.  
The display decrements from the preset to zero. When  
zero is reached, the output is energized for the one-shot  
time. Timing from the preset is restarted at the trailing  
edge of the output. The cycle is repeated until the timer  
is reset.  
K
Reset  
Reset  
One-shot  
Output  
Set value  
Digital display  
Set value  
Digital display  
Control outpu
Control output  
The display increments from zero to the preset. When  
the preset is reached, the output is energized for the  
one-shot time. The display continues to increment until  
the timer is reset.  
The display decrements from the preset to zero. When  
zero is reached, the output is energized for the one-shot  
time. The display continues to decrement until the timer  
is reset.  
NOTE: In modes F and K, when the 99 min 59 s or 99 h 59 min ranges are selected in DOWN display, the overflow values will be  
shown as 9959, 9958, 9957, etc.  
In C mode, the set time should be longer than the one-shot time.  
4
H5AN  
H5AN  
OPERATION MODES (continued)  
Mode  
Elapsed time (UP) display  
Time remaining (DOWN) display  
P
Reset  
Reset  
One-shot  
output  
Set value  
Digital display  
Set value  
Digital display  
Control outpu
Control output  
The display increments from zero to the preset. When  
the preset is reached, the output is energized for the  
one-shot time. The timer restarts its timing, but the  
display is not updated until the one-shot time is up.  
The cycle is repeated.  
The display decrements from the preset to zero. When  
zero is reached, the output is energized for the one-shot  
time. The timer restarts its timing, but the display is not  
updated until the one-shot time is up. The cycle is  
repeated.  
Q
Reset  
Reset  
One-shot  
Output  
Set value  
Digital display  
Set value  
Digital display  
Control output  
Control output  
The display increments from zero to the preset. When  
the preset is reached, the output is energized for the  
one-shot time. The display continues incrementing  
during the one-shot, but restarts from zero when the  
one-shot time is up. The cycle is repeated.  
The display decrements from the preset to zero. When  
zero is reached, the output is energized for the one-shot  
time. The display continues decrementing during the  
one-shot, but restarts from the preset when the one-shot  
time is up. The cycle is repeated.  
NOTE: In mode Q, when the 99 min 59 s or 99 h 59 min ranges are selected in DOWN display, the overflow values will be shown as  
9959, 9958, 9957, etc.  
In P mode, the set time should be longer than the one-shot time.  
Dimensions  
Unit: mm (inch)  
Two mounting  
brackets  
M3.5 terminal  
screws  
67.6  
(2.66)  
72  
(2.83)  
72  
(2.83)  
115 (4.53)  
130 (5.12)  
Panel cutout  
Panel cutout for side-by-side  
mounting for two units  
NOTE: Recommended panel thickness is 1 to 5 mm.  
Panel cutout conforms to DIN 43700.  
5
H5AN  
H5AN  
Connections  
Input terminal number (no-voltage only)  
0 VDC  
COM  
8
Reset  
9
Gate  
10  
Power supply terminal numbers  
AC (common), DC- AC (hot), DC+ Ground  
1
2
3
+
Output terminal numbers  
Power supply for externally connected equipment  
Contact  
Voltage supply  
12 VDC, 80 mA  
DC-  
8
DC+  
11  
COM  
4
NO  
5
NC  
6
Solid-state  
COM  
12  
Load  
13  
Surge absorber  
14  
POWER SUPPLY CONNECTION  
AC power supply  
Connect the required supply voltage to terminals  
1 and 2. In environments with external noise,  
connect ground terminal 3 at a resistance of less  
than 100.  
0 VDC  
only)  
100 to 240 VAC, 50/60 Hz  
LOAD CONNECTION  
Terminals 4, 5 and 6 are for contact output.  
Terminals 12 and 13 are for solid-state output.  
Terminal 14 is a surge absorber for use when  
an inductive load is connected.  
Contact output  
Solid-state output  
Load Operation  
Start  
Time up  
Timing operation  
Load 1  
+
High and low output levels  
are selected by internal switch.  
See "Operations" section for  
setting information.  
Load 2  
HL  
setting  
Load 3  
LH  
setting  
6
H5AN  
H5AN  
RESET AND GATE INPUTS  
Reset input  
Gate input  
Use a no-voltage contact or open  
collector type transistor between  
terminals 8 and 9. The timer resets  
when contact is made or when the  
transistor is ON.  
Use a no-voltage contact or open  
collector type transistor between  
terminals 8 and 10. The timer stops  
when the contact makes or when  
the transistor is ON. When the gate  
signal opens, timing resumes at the  
point of interruption. Use a contact  
with minimum contact bounce (chatter),  
otherwise the bounce time will cause  
an error in the timer's operating time.  
Input signal requirements  
Contact input  
Resistance  
1 kmax.  
Residual voltage  
Contact material  
1 V max. when the contact makes  
Gold-plated contacts recommended  
Solid-state input  
Input type  
Open collector transistor  
20 V min.  
Voltage when collector is OFF  
Saturated voltage when transistor is ON  
Collector current  
3 V max.  
50 mA min.  
0.5 µA max.  
Input current between collector and base  
Solid-state inputs (NPN)  
current that flows from either terminal 9 or  
10 is approximately 10 mA). Moreover, it is  
essential that the circuit be ON for gate or  
reset input, and OFF when there is no input.  
When connecting a solid-state circuit not of  
the open collector type to the gate or reset  
inputs as shown in the figure below, the  
voltage of the solid-state circuit (+ V)  
should be 13 to 30 V, and the VCE(S) of the  
transistor should be less than 3 V (the  
POWER SUPPLY FOR EXTERNALLY-CONNECTED COMPONENTS  
Gate or Reset input  
Solid-state output load  
The H5AN has a built-in power supply for  
externally connected components such as  
sensors for gate or reset input, or loads  
connected to the solid-state control output  
(12 VDC, 80 mA).  
Power can be applied to the sensors and  
loads simultaneously.  
7
H5AN  
H5AN  
SIMULTANEOUS INPUT TO SEVERAL H5AN TIMERS  
A single contact or open collector type transistor  
can be used to apply the gate or reset input to  
two or more H5AN timers. Caution is required  
because a large current flows into the transistor.  
The current that flows from H5AN is approximately  
10 mA per unit.  
Operation  
NOMENCLATURE  
7-segment LED display  
Time-up indicator  
Reset input indicator  
Pushbutton switch for manual reset  
Maintenance access screw  
Front cover  
One-Shot time adjustment screw  
(0.1 to 1 sec range)  
Time range decal  
ACCESS TO SELECTOR SWITCHES  
Open the front cover.  
Use a Phillips screwdriver  
to gain access to internal  
parts. As the maintenance  
access screw is turned, the  
internal mechanism draws  
out. Pull out the timer from  
its case to set internal  
switches to desired settings.  
8
H5AN  
H5AN  
PROGRAMMING H5AN SPECIFICATIONS  
Internal selector switches are used for programming  
elapsed time (UP) or time remaining (DOWN) display,  
time range, operation mode and solid-state output level.  
Operation mode selector  
Manual reset (front panel)  
enable switch  
Switch  
Operation  
Solid-state output  
level selector switch  
position Mode  
Display mode  
Changed "low" to "high" when time is up  
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
N
Changed "high" to "low" when time is up  
F
C
Time remaining  
(DOWN) display  
Time range selector settings  
R
K
Switch  
position Time range  
P
0
1
2
3
4
5
6
7
8
9
0.01 to 99.99 s  
0.1 to 999.9 s  
1 to 9999 s  
Q
(same as 0)  
N
1 s to 99 min 59 s  
0.1 to 999.9 min  
1 min to 99 h 59 min  
0.1 to 999.9 h  
1 to 9999 h  
F
C
Elapsed time  
(UP) display  
R
Operation mode  
selector switch  
Time range  
selection switch  
K
P
same as "0"  
Q
same as "1"  
(same as 8)  
SETTING TIME PRESET  
Use the four pushwheel switches on the front  
panel to set the desired time. The H5AN timer  
does not display the decimal point in ranges for  
99.99 sec, 999.9 sec, 999.9 min or 999.9 hr.  
Firmly push the switches to avoid having two  
numbers appear in the display window. This  
causes the operating time to drift widely.  
Undesirable setting  
Warning  
Do not set all four digits to  
zero. This causes a momentary  
output to occur that may lead to  
accidental injury or damage.  
5 min  
30 second  
In the 99 hr 59 min and 99 min 59 sec  
ranges, the second digit from the right  
cannot be more than 5. Even if the digit  
is set to 6, 7, 8 or 9, the setting will be  
interpreted as 5.  
00 h 00 min  
(Momentary  
output)  
59 min  
99 h  
9
9
7
9
Any digit higher  
than 5 will be  
interpreted as 5.  
SETTING ONE-SHOT TIME  
Output modes C, R, K, P and Q provide a one-  
shot output. Be sure to set the one-shot value,  
between 0.1 and 1 second, using the poten-  
tiometer in the lower right corner of the front  
panel.  
9
H5AN  
H5AN  
PROGRAMMING CONSIDERATIONS FOR TIMERS WITH MEMORY PROTECTION  
For units with memory protection, it is  
necessary to reset (either externally or  
manually) the timer at the time the power is  
applied. If the timer is not reset, it operates  
in accordance with the previous data. Also  
reset the timer after any changes are made  
to the internal switches.  
RECOVERY FROM A POWER FAILURE  
H5AN-4D  
H5AN-4DM  
This timer has a battery backed memory to  
protect settings against power failure.  
When a power failure occurs, the timing  
operation is interrupted. When power  
returns, the timer continues from the point  
of interruption.  
The duration of the power failure determines how the  
timer acts when power is restored.  
With a power failure of less than 0.01 second duration,  
the timer resumes timing from the point of interruption  
upon recovering power.  
The back-up battery will retain data for up  
to 10 years. However, the battery may not  
be replaced.  
Length of power failure  
0.01 sec or less  
Action when power is restored  
Timer resumes timing and does not reset  
Timer either resets or resumes timing  
Timer resets  
0.01 sec to 0.5 sec  
0.5 sec or more  
NOTE: ALL DIMENSIONS ARE IN MILLIMETERS. To convert millimeters into inches divide by 25.4.  
OMRON ELECTRONICS, INC.  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. GC TI8  
11/97  
Specifications subject to change without notice.  
Printed in the U.S.A.  

相关型号:

H5AN-4DM-AC100-240

Analog Circuit
OMRON

H5AN-4DM-AC24

Analog Circuit
OMRON

H5AN4G6NMFR-TFC

DDR DRAM, 256MX16, CMOS, PBGA96, FBGA-96
HYNIX

H5AN4G6NMFR-UHC

DDR DRAM, 256MX16, CMOS, PBGA96, FBGA-96
HYNIX

H5AN4G8NMFR-TFC

DDR DRAM, 512MX8, CMOS, PBGA78, FBGA-78
HYNIX

H5B-M1

DIN 48X48 ON DELAY TIMER/FLICKER
FOTEK

H5B-M1H

DIN 48X48 ON DELAY TIMER/FLICKER
FOTEK

H5B-M3

DIN 48X48 ON DELAY TIMER/FLICKER
FOTEK

H5B-M3H

DIN 48X48 ON DELAY TIMER/FLICKER
FOTEK

H5B-M6

DIN 48X48 ON DELAY TIMER/FLICKER
FOTEK

H5B-M6H

DIN 48X48 ON DELAY TIMER/FLICKER
FOTEK

H5B-TF-10S

OFF DELAY TIMER
FOTEK