下载:  下载PDF数据表文档文件
Digital Timer  
H5CN  
1/16 DIN, Quartz Timer with  
Four-Digit LED Display  
Five wide ranges to choose from  
Wide-range AC or DC supply voltages  
Elapsed time (UP) or time remaining  
(DOWN) display available  
Selectable no-voltage reset and gate  
inputs expand capabilities  
Memory protection circuit available on  
AC models; order back-up battery  
separately from accessories  
Easy-to-read 8 mm-high LED display  
Panel mounting adapter, sockets, and  
accessories may be ordered separately  
Ordering Information  
TIMERS  
NOTE: The complete part numbers shown here are the only H5CN timers currently available.  
Some time ranges and supply voltages have been discontinued.  
Timing functions  
Contact type  
ON-delay  
SPDT relay  
Elapsed time (UP)  
Not provided  
8-pin round  
socket  
Solid-state open collector  
Display type  
Time remaining (DOWN) Elapsed time (UP)  
Memory protection  
Terminal form  
Provided  
11-pin round  
socket  
Not provided  
Not provided  
8-pin round socket  
8-pin round socket  
Part  
number  
0.001 to 9.999 sec  
0.01 to 99.9 sec  
H5CN-XZNS-AC100-240  
H5CN-XZNS-DC12-48  
H5CN-XAN-AC24  
H5CN-XAN-AC100-240  
H5CN-XAN-DC12-48  
H5CN-XBN-AC24  
H5CN-XANM-AC100-240  
H5CN-YAN-AC100-240  
H5CN-YAN-DC12-48  
H5CN-XANS-AC100-240  
H5CN-XANS-DC12-48  
0.1 to 999.9 sec  
H5CN-XBN-AC100-240  
H5CN-XBN-DC12-48  
H5CN-XCN-AC24  
H5CN-XBNM-AC100-240  
H5CN-YBN-AC100-240  
H5CN-YBN-DC12-48  
H5CN-YCN-AC24  
H5CN-YCN-AC100-240  
H5CN-YCN-DC12-48  
H5CN-XBNM-DC12-48  
1 s to 99 min 59 s  
1 min to 99 h 59 min  
H5CN-XCN-AC100-240  
H5CN-XCN-DC12-48  
H5CN-XDN-AC24  
H5CN-XCNM-AC100-240  
H5CN-XDN-AC100-240  
H5CN-XDN-DC12-48  
H5CN-XDNM-AC100-240  
H5CN-YDN-AC100-240  
H5CN-YDN-DC12-48  
1
H5CN  
H5CN  
ACCESSORIES  
Description  
Part number  
P2CF-08  
P3G-08  
Sockets H5CN-N  
timers  
Bottom surface or track mounting, top screw terminals  
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals.  
Bottom surface or track mounting, top screw terminals  
H5CN-❑❑M  
timers  
P2CF-11  
P3GA-11  
Y92F-30  
Y92S-20  
Y92A-48B  
Y92A-48D  
PFP-50N  
PFP-100N  
PFP-M  
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals  
Fits behind panel, ideal for side by side installation. Use P3G-sockets.  
Panel mounting adapter  
Battery for memory backup Use with H5CN-❑❑M timers.  
Protective cover  
Hard plastic cover  
Soft plastic cover; allows settings to be changed through the cover.  
Mounting track  
DIN rail, 50 cm (1.64 ft) length  
DIN rail, 1 m (3.28 ft) length  
End plate  
Spacer  
PFP-S  
Specifications  
Part number  
H5CN-XN  
H5CN-XNM  
H5CN-YN  
H5CN-XNS  
Supply  
voltage  
AC  
DC  
24 V, 100 to 240 V; 50/60 Hz  
100 to 240 V; 50/60 Hz  
12 to 48 V (permissible ripple factor; 20% max.)  
85 to 110% of the rated voltage  
12 VA at 240 VAC, 50/60 Hz  
Operating voltage  
AC  
DC  
Power  
consumption  
2.5 W at 48 VDC  
2.5 W at 48 VDC  
ON-delay with time  
remaining display  
ON-delay with elapsed  
time display  
Timing  
functions  
ON-delay with elapsed time display  
Reset, gate inputs  
No voltage  
SPDT relay  
Control  
output  
Open collector  
solid-state  
Type  
Time limit  
Instantaneous  
Max. load  
Min. load  
3 A, 250 VAC (p.f. = 1)  
10 mA, 5 VDC  
100 mA max. 30 VDC  
Repeat accuracy  
Setting error  
Resetting system  
Resetting time  
Indicators  
±0.01% ±0.05 sec max. (power-ON start); ±0.005% ±0.03 sec max. (reset start)  
See "Repeat accuracy"  
Power-OFF and external reset  
Power OFF: 0.5 sec min.; External reset: 0.02 sec signal min.  
Time UP (red LED), 8 mm LED numeric display  
Plastic  
Materials  
Mounting  
Panel, track, surface  
Connections  
Weight  
8-pin round socket  
150 g (5.31 oz.)  
UL/CSA/SEV  
11-pin round socket 8-pin round socket  
Approvals  
Operating ambient temperature  
Humidity  
-10° to 55°C (14° to 131°F)  
35 to 85% RH  
Vibration Mechanical durability  
Malfunction durability  
10 to 55 Hz; 0.75 mm (0.03 in) double amplitude  
10 to 55 Hz; 0.5 mm (0.02 in) double amplitude  
30 G  
Shock  
Mechanical durability  
Malfunction durability  
10 G  
Variation due to voltage change  
Variation due to temperature change  
Insulation resistance  
See "Repeat Accuracy"  
See "Repeat Accuracy"  
100 Mmin. at 500 VDC  
Dielectric strength  
2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed non-  
current-carrying metal parts, between power supply circuit, and control output circuit  
Service life  
Mechanical  
Electrical  
10 million operations minimum  
Not applicable  
Not applicable  
100,000 operations minimum at maximum ratings  
2
H5CN  
H5CN  
Engineering Data  
ELECTRICAL SERVICE LIFE  
Note: The service life graphs apply  
to all relay output models.  
They do not apply to solid-state  
output models H5CN-XZNS or  
H5CN-XANS.  
Timing Charts  
ELAPSED TIME (UP) DISPLAY  
Time up  
Reset input  
ON  
OFF  
Gate input (interruption)  
ON  
OFF  
Set value  
Digital display  
Control output (NO)  
Time UP indicator  
ON  
OFF  
ON  
OFF  
TIME REMAINING (DOWN) DISPLAY  
Time up  
Reset input  
ON  
OFF  
Gate input (interruption)  
ON  
OFF  
Set value  
Digital display  
Control output (NO)  
Time UP indicator  
ON  
OFF  
ON  
OFF  
3
H5CN  
H5CN  
Dimensions  
Unit: mm (inch)  
TIMERS  
Panel cutout  
50  
45  
(1.77)  
(1.97)  
45  
(1.77)  
48  
(1.89)  
44.8  
(1.76)  
50  
(1.97)  
48  
(1.89)  
97.4  
(3.84)  
Note: Recommended panel  
thickness is 1 to 3.2 mm.  
Panel cutout conforms to  
DIN 43700.  
SOCKETS  
8-Pin Sockets for H5CN-XN, H5CN-YN and H5CN-XNS  
P2CF-08 Bottom Surface or Track Mounting  
Eight  
M3.5 x 7.5  
sems  
4.5  
3
Mounting holes  
Terminal arrangement  
7.8  
Two 4.5 dia. or two M4  
socket mounting holes  
70 max.  
35.4  
Two  
4.5 dia.  
mounting  
holes  
50  
max.  
(Top view)  
20 max.  
(0.79)  
P3G-08 Back Mounting Socket  
Terminal arrangement  
(Bottom view)  
11-Pin Sockets for H5CN-XNM  
P2CF-11 Bottom Surface or Track Mounting Socket  
Eleven  
M3.5 x 7.5  
sems  
3
4.5  
7.8  
Mounting holes  
Terminal arrangement  
Two 4.5 dia. socket  
mounting holes  
35.4  
74 max.  
(2.91)  
Two  
40±0.2  
(1.57)  
4.5 dia.  
mounting  
holes  
50  
max.  
31.2  
(1.23)  
max.  
(Top view)  
4
H5CN  
H5CN  
P3GA-11 Back Mounting Socket  
Terminal arrangement  
PANEL MOUNTING ADAPTER  
Y92F-30 Mounting Adapter  
Adapter installs behind the panel. It is ideal for side by side installation. Use P3GA-11 or P3G-08 sockets.  
Mounting  
Panel  
P3G-❑  
socket  
adapter  
Panel cutout  
(1.77)  
(2.28)  
58  
(1.77)  
Note: Recommended  
panel thickness  
48  
(1.89)  
is 1 to 3.2 mm.  
(3.78)  
BATTERY FOR MEMORY BACK-UP  
Y92S-20 Battery  
Use this battery with H5CN-XNM timers with memory protection circuit. While the timer's  
built-in memory protection circuit can retain values for power failures lasting up to 10  
minutes, the optional battery protects memory in case of a longer power outage. We  
recommend using the battery as a safeguard. Memory values can be retained for up to 5  
years.  
31.0  
(1.2)  
Lead wire with spade lug  
120 mm (4.72 in) length  
(+)  
( – )  
4.5 dia. hole  
PROTECTIVE COVERS  
Hard plastic cover Y92A-48B and soft  
plastic cover Y92A-48D snap onto the front  
of the timer to protect against dirt and  
water. The Y92A-48B hard plastic cover  
prevents accidental resetting. Y92A-48D  
soft plastic cover fits snugly over the front  
and allows settings to be changed. These  
covers are intended for use in areas where  
unusual service conditions do not exist.  
Y92A-48B Hard Plastic Cover  
Y92A-48D Soft Plastic Cover  
50.5  
(1.99)  
50.5  
(1.99)  
16 (0.63)  
overall  
depth  
5
H5CN  
H5CN  
MOUNTING TRACK AND ACCESSORIES  
PFP-100N/PFP-50N DIN Rail  
PFP-M End Plate  
PFP-S Spacer  
44.3  
(1.74)  
16  
(0.63)  
50  
(1.97)  
37.3  
(1.47)  
Connections  
Part  
number  
Input terminal number (no-voltage only)  
Power supply terminal numbers  
Output terminal numbers  
COM NC NO DC- DC+  
COM  
Gate  
Reset  
AC (common), DC– AC (hot), DC+  
H5CN-N  
H5CN-❑❑S  
H5CN-❑❑M  
1
1
3
4
4
5
3
3
7
2
2
2
7
7
8
8
5
6
6
4
8
10  
11  
9
1
H5CN-N Timer  
H5CN-❑❑S Timer  
H5CN-❑❑M Timer  
Note: Internal (isolated) contacts are shaded.  
POWER SUPPLY  
H5CN-N and H5CN-❑❑S Timers  
H5CN-❑❑M Timers  
Connect the timer so that the supply voltage is  
applied to terminals 2 and 7. This is for models  
without memory protection.  
For models with memory protection, connect  
the supply voltage to terminals 2 and 10.  
CONTROL OUTPUT  
Timed contact output type H5CN-N  
Terminals 5, 6 and 8 are used for the output  
relay. A normally open contact (Load 1) is  
connected between terminals 6 and 8. A  
normally closed contact (Load 2) is connected  
between terminals 5 and 8.  
6
H5CN  
H5CN  
Timed Solid-state output type H5CN-XNS  
The solid-state output uses an open collector  
type transistor. Connect terminal 6 (collector) to  
the positive terminal of the load. Connect  
terminal 8 (emitter) to the negative terminal. A  
built-in surge suppression diode on terminal 5  
should be connected to the positive terminal of  
the load when the timer switches an inductive  
load.  
Timed contact output with memory protection H5CN-XNM  
Terminals 8, 9 and 11 are used for the output relay.  
A normally open contact (Load 1) is connected  
between terminals 9 and 11. A normally closed  
contact (Load 2) is connected between terminals  
8 and 11.  
INPUT REQUIREMENTS  
Contact  
Solid-State  
Resistance  
1 Kmax.  
Input type  
Open collector transistor  
20 V min.  
Residual voltage  
Contact material  
1 V max. when the contact makes  
Gold-plated contacts  
Voltage when collector is OFF  
Collector current  
50 mA min.  
Input current between  
collector and base  
Note: Select a contact with short bounce time. Contact  
bounce causes an error in the operate time equal  
to bounce time.  
0.6 mA max.  
RESET INPUT  
Timers without memory protection H5CN-❑❑, H5CN-❑❑S  
Connect a no-voltage contact or an open collector transistor  
output to terminals 1 and 3. The timer resets when contact  
is made or when the transistor turns ON.  
Timers with memory protection H5CN-XNM  
Connect a no-voltage contact or an open collector transistor  
output to terminals 3 and 7. The timer resets when contact  
is made or when the transistor turns ON.  
7
H5CN  
H5CN  
GATE INPUT  
Cumulative Timing Using the Gate Input with ON-Delay  
ON  
Power supply–  
Gate input–  
When the gate signal is closed, timing is temporarily  
stopped. When the gate signal opens, timing resumes  
at the point of interruption. The gate input terminal  
permits the timer to sum up times T1, T2 and T3 as  
shown in the timing chart.  
[
OFF  
Interruption  
Interruption  
ON  
[
OFF  
Time up  
T1  
T2  
5
T3  
ON  
Digital display–  
0
1
2
3
3
4
6
7
7
8
9
10  
[
OFF  
ON  
Control output–  
[
OFF  
Preset time = 10 seconds  
Timers without memory protection H5CN-❑❑, H5CN-❑❑S  
Connect a no-voltage contact or an open collector  
transistor output to terminals 1 and 4. The gate  
input interrupts timing when the contact closes or  
when the transistor is ON. Timing resumes from the  
point of interruption when the gate input is  
removed.  
Timers with memory protection H5CN-❑❑M  
Connect a no-voltage contact or an open collector  
transistor output to terminals 3 and 5. The gate  
input interrupts timing when the contact closes or  
when the transistor is ON. Timing resumes from  
the point of interruption when the gate input is  
removed.  
BATTERY FOR MEMORY PROTECTION  
Connect the Y92S-20 battery between terminals 1  
and 4 on H5CN-❑❑M timers. The 3 V lithium  
battery is in a holder with lead wire and termina-  
tions. It may be used to preserve timer memory  
for power outages that are longer than 10 minutes  
duration. Because power failure duration is  
unpredictable, we recommend using Y92S-20 for  
long-term memory back up.  
SIMULTANEOUS INPUT TO SEVERAL H5CN TIMERS  
For expanded convenience, input signal may  
be used to apply gate and reset signals to  
several H5CN timers. Also a combination of  
gate to some and reset to other timers is  
possible. Timers with and without memory  
backup may be used together. Pay attention  
to the different terminal numbers required for  
gate and reset when mixing timer types.  
Gate input, without memory protection  
Gate input, with memory protection  
8
H5CN  
H5CN  
Simultaneous input to H5CN, continued  
Reset input, without memory  
Reset input, with memory protection  
Reset and gate inputs, without memory  
Reset and gate inputs, with memory protection  
Operation  
SETTING THE TIME PRESET  
Use the four pushwheel switches on the front panel to  
set the desired time. The H5CN timer does not display  
the decimal point. Firmly push the switches to avoid  
having two numbers appear in the display window.  
This causes the operating time to drift widely.  
Undesirable settings  
WARNING  
Do not set all four digits to  
zero. This causes a momentary  
output to occur that may lead to  
accidental injury or damage.  
5 min 30 s?  
25 min 30 s?  
35 min 30 s?  
Do not change the setting while the timer is powered  
up. It may cause a momentary output to occur.  
Mounting  
PANEL MOUNTING  
Using Y92F-30 Adapter  
Insert the timer through the panel cutout. Push the Y92F-30  
adapter from the rear of the timer as far forward toward the  
panel as possible. Push the P3G-socket onto the rear  
of the timer. Then wire the socket. Tighten the two retaining  
screws. To release the adapter, lift the tab at the rear of the  
adapter.  
9
H5CN  
H5CN  
Using Y92F-30 Adapter (continued)  
Panel cutout for side-by-side  
mounting of two timers  
Several timers may be panel mounted close  
together using Y92F-30 adapter as shown  
here. When mounting two or more timers in  
a vertical line, arrange the adapters so that  
their molded tabs are positioned on the  
right and left sides. When mounting two or  
more timers in a horizontal line, arrange the  
adapters so that their molded tabs are  
positioned on the top and bottom sides.  
Molded  
tab  
Molded  
tab  
P2CF-Socket  
Removal  
Mounting  
Pull the latch on the socket with a flat-  
blade screwdriver and remove the timer  
and socket as one unit.  
The P2CF-socket has two hooks that  
secure the timer to the socket. Be sure to  
allow at least 20 mm (0.79 in)  
clearance above and below the  
socket to gain access and to release  
the hooks for servicing and mainte-  
nance. Insert timer into the socket.  
Latch hooks. Then clip rear of the  
socket to the track. Push the bottom  
onto the track until the latch hooks  
securely.  
NOTE: ALL DIMENSIONS ARE IN MILLIMETERS. To convert millimeters into inches divide by 25.4.  
OMRON ELECTRONICS, INC.  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. GC TI8  
11/97  
Specifications subject to change without notice.  
Printed in the U.S.A.  

相关型号:

H5CN-XAN-AC100-240

Analog Circuit
OMRON

H5CN-XANM-AC100-240

Analog Circuit
OMRON

H5CN-XANS-AC100-240

Analog Circuit
OMRON

H5CN-XBN-AC24

Analog Circuit
OMRON

H5CN-XBNM-AC100-240

Analog Circuit
OMRON

H5CN-XCN-DC12-48

Analog Circuit
OMRON

H5CN-XDN-AC24

Analog Circuit
OMRON

H5CN-XDN-DC12-48

Analog Circuit
OMRON

H5CN-YCN-AC100-240

Analog Circuit
OMRON

H5CN-YCN-AC24

Analog Circuit
OMRON

H5CN-YDN-DC12-48

Analog Circuit
OMRON

H5CNXZNS-DC12-48

Analog Circuit
OMRON