Electronic Components Datasheet Search
English 中文版
Manufacturer Upload
Part Name:
 
Description:
AC-162ESAW-H  AC-162ESALY-  91C1AB24B20R51  AC-162ESBEW-H  AC-162ESBEW-  91C1AD24B13R51  91C1AB28D15R51  91C1AB28A10R51  AC-162ESBB-  91C1AD22D18R51  
H7CX-A114USDG Multifunction Preset Counter
Prototype PCB
Part No.:   H7CX-A114USDG
Download: Download   Right selection Save Target As
View Datasheet (Html)   No need to install PDF reader software
Description:   Multifunction Preset Counter
File Size :   2406 K    
Page : 43 Pages
Logo:   
Maker   OMRON [ OMRON ELECTRONICS LLC ]http://www.omron.com
Buy Now :   
  H7CX-A114USDG Datasheet PDF page 3 H7CX-A114USDG Datasheet PDF page 4 H7CX-A114USDG Datasheet PDF page 5 H7CX-A114USDG Datasheet PDF page 6 H7CX-A114USDG Datasheet PDF page 8 H7CX-A114USDG Datasheet PDF page 9 H7CX-A114USDG Datasheet PDF page 10 H7CX-A114USDG Datasheet PDF page 11  
100%
Connections
I
Block Diagram
Output circuit
(Basic
insulation)
Input circuit
Internal control
circuit
(Basic
insulation)
Power supply
circuit
Display circuit
Key switch
circuit
Note:
All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation.
I
I/O Functions
Using as a Counter
Inputs
CP1, CP2
In general (except for dual counter mode)
Reads counting signals
Increment, decrement, command, individual, and quadrature inputs accepted.
When used as a dual counter
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
Increment signals can be input.
In general (except for dual counter mode)
Resets present value and outputs (OUT2 when using the batch counter). (See note 1.)
Counting cannot be performed during reset/reset 1 input.
The reset indicator is lit during reset input.
When used as a dual counter
Resets the CP1 present value (to 0).
Counting for CP1 input cannot be performed during reset 1 input.
The reset indicator is lit during reset 1 input.
When used as a 1-stage/2-stage counter
Does not operate (Not used).
When used as a total and preset counter
Resets the total count value.
Holds the total count value at 0 during total reset input.
When used as a batch counter
Resets the batch count value and batch output (OUT1).
Holds the batch count value at 0 during reset 2 input.
When used as a dual counter
Resets the CP2 present value.
Counting for CP2 input cannot be performed during reset 2 input.
Outputs take place according to designated output mode when corresponding preset is reached.
Reset or Reset 1
Total Reset or
Reset 2
(See note 2.)
Outputs
OUT1, OUT2
Note: 1.
In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the
set value with 1-stage models, and returns to set value 2 with 2-stage models.
2.
The reset indicator will not be lit when the total reset or reset 2 input is ON.
Using as a Tachometer
Inputs
CP1, CP2
Reset 1, Reset 2
Outputs
OUT1, OUT2
Reads counting signals. (CP2 input is not used.)
Holds the measurement value and outputs. (Reset 2 input is not used.)
The reset indicator is lit during hold.
Outputs signals according to the specified output mode when a set value is reached.
Multifunction Preset Counter
H7CX