H7ER-NV1-B [OMRON]

Analog Circuit;
H7ER-NV1-B
型号: H7ER-NV1-B
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Analog Circuit

文件: 总11页 (文件大小:202K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Self--powered Tachometer  
H7ER  
Subminiature Tachometers With  
Improved Appearance and Features  
Large display with 8.6 mm (0.338 in)  
height  
Available with backlit LCD  
Revolutions displayed up to five digits.  
PNP/NPN DC voltage input available  
Switchable dual revolution display type  
available (-NV1 models); extended up to  
10000 m-- 1 {rpm}  
Dual revolution display according to  
encoder resolution used; 1000 s-- 1  
{rps}/1000 m-- 1 {rpm} or 1000.0 s-- 1  
{rps}/1000.0 m-- 1 {rpm}  
NEMA 4/IP66 front  
Replaceable battery  
New black case  
Ordering Information  
TACHOMETERS  
Max. revolutions displayed (applicable encoder resolution)  
Count input  
Display  
-- 1  
-- 1  
1000 s {rps} (1 pulse/rev.),  
1000.0 s {rps} (10 pulse/rev.),  
-- 1  
-- 1  
1000 m {rpm} (60 pulse/rev.)  
1000.0 m {rpm} (600 pulse/rev.) ←→  
-- 1  
10000 m {rpm} (60 pulse/rev.) (switchable)  
Part number  
H7ER-NV-BH  
PNP/NPN  
universal DC  
voltage input  
7-segment LCD  
with backlight  
H7ER-NV1-BH  
7-segment LCD  
7-segment LCD  
H7ER-NV-B  
H7ER-N-B  
H7ER-NV1-B  
No-voltage input  
---  
MODEL NUMBER LEGEND  
H7ER - N  
-
4
1
2
3
1. Count Input  
3. Case Color  
None: No-voltage input  
B:  
Black  
V:  
PNP/NPN universal DC voltage input  
4. Display  
None: 7-segment LCD without backlight  
2. Number of Digits  
None: 4 digits  
H:  
7-segment LCD with backlight  
1:  
5 digits  
H7ER  
H7ER  
ACCESSORIES (ORDER SEPARATELY)  
Item  
Part number  
Y92S-36  
Replacement Battery  
Wire-wrap Terminal (Set of two Terminals)  
Flush Mounting Adapter  
Y92S-37  
Y92F-75  
26 mm  
45 mm  
48.8 mm  
Y92F-77B  
24.8 mm  
Specifications  
GENERAL  
Item  
H7ER-NV-B  
H7ER-NV-BH  
H7ER-N-B  
H7ER-NV1-B  
H7ER-NV1-BH  
Operating mode  
Mounting method  
External connections  
Display  
Up type  
Flush mounting  
Screw terminals, Wire-wrap Terminals (See Note 3.)  
7-segment LCD with or without backlight (character height: 8.6 mm) (See Note 4.)  
Number of digits  
Count input  
4
5
PNP/NPN universal DC  
voltage input  
No-voltage input  
PNP/NPN universal DC voltage input  
Max. counting speed  
1 kHz  
10 Hz  
-- 1  
-- 1  
Max. revolutions displayed (See 1,000 s {rps} (When encoder resolution of  
1,000.0 s {rps} (When encoder  
Note 5.)  
1 pulse/rev is used.)  
1,000 m {rpm} (When encoder resolution of  
resolution of 10 pulse/rev is used.)  
1,000.0 m {rpm} (When encoder  
-- 1  
-- 1  
60 pulse/rev is used.)  
resolution of 600 pulse/rev is used.)  
←→ 10,000 m {rpm} (When encoder  
-- 1  
resolution of 60 pulse/rev is used.)  
(Switchable with switch)  
Attachment  
Waterproof packing, flush mounting bracket, revolution unit labels (See Note 5.)  
Approved standard  
UL508, CSA C22.2 No.14, Lloyds  
Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category  
)
Conforms to VDE0106/P100  
Note: 1. Reset is not available.  
2. When there is no input, the display will be 0.0 or 0.  
3. Wire-wrap Terminals (Y92S-37) can be ordered separately  
4. Only PNP/NPN Universal DC voltage input models are available with a backlight.  
-- 1  
-- 1  
5. “rpm,” “rps,” “s ,” and “m ,” labels are included.  
RATINGS  
Item  
H7ER-NV -B  
H7ER-N-B  
H7ER-NV -BH  
Supply voltage  
Backlight model: 24 VDC (for backlight lit)  
No-backlight model: Not required (powered by  
battery)  
Not required (powered by battery)  
High (logic) level: 4.5 to 30 VDC  
Low (logic) level: 0 to 2 VDC  
(Input impedance: Approx. 4.7 k)  
No voltage input  
Count input  
Maximum short-circuit impedance: 10 kmax.  
Short-circuit residual voltage: 0.5 V max.  
Minimum open impedance: 750 kmin.  
Reset input  
Max. counting speed  
Minimum signal width  
5-digit models: 10 Hz  
4-digit models: 1 kHz  
1 kHz  
10 Hz: 0.05 ms  
1 kHz: 0.5 ms  
Terminal screw tightening torque 0.98 N m max.  
Ambient temperature  
Operating: --10°C to 55°C (with no icing)  
Storage: --25°C to 65°C (with no icing)  
Ambient humidity  
Operating: 25% to 85%  
2
H7ER  
H7ER  
CHARACTERISTICS  
Item  
H7ER-NV -B  
H7ER-N-B  
H7ER-NV -BH  
Insulation resistance  
100 Mmin. (at 500 VDC) between  
100 Mmin. (at 500 VDC) between  
current-carrying metal parts and exposed  
non-current-carrying metal parts  
current-carrying metal parts and exposed  
non-current-carrying metal parts, and between  
the backlight power supply and count input  
terminals/reset terminals for backlight models  
Dielectric strength  
1,000 VAC, 50/60 Hz for 1 min between  
current-carrying metal parts and exposed  
non-current-carrying metal parts and between  
the backlight power supply and count input  
terminals/reset terminals for backlight models  
1,000 VAC, 50/60 Hz for 1 min between  
current-carrying metal parts and exposed  
non-current-carrying metal parts  
Impulse withstand voltage  
Noise immunity  
4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts  
Between input terminals: ±600 V in normal  
mode, ±1.5 kV in command mode  
For backlight power supply (backlight model):  
±480 V in normal mode, ±1.5 kV in command  
mode  
±500 V in normal mode, ±1.5 kV in command  
mode  
Static immunity  
±8 kV (malfunction)  
Vibration resistance  
Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions  
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions  
2
Shock resistance  
Malfunction: 200 m/s 3 times each in 6 directions  
2
Destruction: 300 m/s 3 times each in 6 directions  
Battery life  
EMC  
7 years min. with continuous input at 25°C (lithium battery)  
(EMI)  
EN50081-1  
EN55022 class B  
Emission Enclosure:  
(EMS)  
Immunity ESD:  
EN50082-2  
EN61000-4-2: 4-kV contact discharge (level 2)  
8-kV air discharge (level 3)  
Immunity RF-interference from AM Radio Waves:  
ENV50140:  
10 V/m (80 MHz to 1 GHz) (level 3)  
Immunity RF-interference from Pulse-modulated Radio Waves:  
ENV50204:  
20 V/m (900 MHz ± 5 MHz) (level 3)  
10 V (0.15 to 80 MHz ) (level 3)  
Immunity Conducted Disturbance: ENV50141:  
Immunity Burst:  
EN61000-4-4: 2-kV power line (level 3)  
2-kV I/O signal line (level 4)  
Enclosure rating  
Front panel:  
Terminal block:  
IP66, NEMA4  
IP20  
Weight (see Note.)  
Non-backlight model: Approx. 60 g  
Backlight model: Approx. 65 g  
Note: Weight includes waterproof packing and panel mounting bracket.  
3
H7ER  
H7ER  
Nomenclature  
Front view  
TACHOMETER  
Not used  
Counting speed switch  
For H7ER-NV1-  
Bottom view  
Counting Speed Switch Settings and Unit Label Application  
Counting speed  
switch setting  
(see note)  
Max. revolutions  
displayed  
Applicable encoder  
resolution  
Applicable unit  
label  
Model  
Front panel  
-- 1  
-- 1  
H7ER-NV1-  
10000 m {rpm}  
60 pulse/rev.  
“m ’ or “rpm”  
(default setting)  
-- 1  
-- 1  
1000.0 m {rpm}  
600 pulse/rev.  
“m ’ or “rpm”  
-- 1  
-- 1  
1000.0 s {rps}  
“s ’ or “rps”  
10 pulse/rev.  
60 pulse/rev.  
Terminal block  
H7ER-N-  
H7ER-NV-  
No setting is  
required  
-- 1  
-- 1  
1000 m {rpm}  
“m ’ or “rpm”  
-- 1  
-- 1  
1000 s {rps}  
1 pulse/rev.  
“s ’ or “rps”  
Note: Perform switch setting before mounting to a control panel.  
Operation  
OPERATING MODES  
H7ER Tachometer  
Incrementing Operation  
Within Unit Time (Up)  
Count period  
(1 s)  
Count period  
(1 s)  
0.25 s  
Internal gate  
Display refreshed Refresh  
Counter reset  
Internal count value  
Number display  
Previous count  
value display  
Display refreshed Display refreshed  
every 1.25 s every 1.25 s  
4
H7ER  
H7ER  
Dimensions  
Unit: mm (inch)  
H7ER-N  
44.8  
(1.76)  
Panel Cutout  
Separate mounting  
60 min.  
24  
(0.94)  
22  
(0.87)  
60 min.  
48  
(1.89)  
2
48.5  
(1.91)  
5
45+0.5  
0
22.2+0.5  
0
Joint mounting  
Dimensions with Flush Mounting Bracket  
+10  
0
(48 Units - 2.5)  
44.8  
(1.76)  
22.2+0.5  
0
Waterproofing is not possible  
for joint mounting  
Whenmounting, inserttheCounterinto  
the cutout. Insert the adapter from the  
back and push in the Counter while  
makingthegapbetweenthefrontpanel  
and the cutout panel as small as  
possible. Use screws to secure the  
Counter. If waterproofing is desired,  
insert the waterproof packing.  
35  
(1.38)  
37  
(1.46)  
24  
22  
When several Counters are installed,  
ensure that the ambient temperature  
will not exceed specifications.  
48  
2
48.5  
5
The appropriate thickness of the panel  
is 1 to 5 mm.  
Installation  
TERMINAL ARRANGEMENT  
Bottom view: View of the Tachometer rotated horizontally 180°  
Backlight Model  
Non-backlight Model  
Backlight  
24 VDC  
Pulse  
input  
Pulse  
input  
5
H7ER  
H7ER  
Connections  
Note: Select input transistors according to the following:  
Dielectric strength of the collector  
50 V  
Leakage current < 1 µA  
NON-VOLTAGE INPUT MODEL  
PNP/NPN UNIVERSAL DC VOLTAGE  
INPUT MODELS WITH BACKLIGHT  
Transistor Input  
Transistor Input (Open Collector of an NPN Transistor)  
Open collector of  
Open collector of  
an NPN transistor  
Open collector of  
an PNP transistor  
an NPN transistor  
or  
Input  
Backlight  
24 VDC  
Input  
PNP/NPN UNIVERSAL DC VOLTAGE INPUT  
MODELS WITHOUT BACKLIGHT  
Transistor Input  
Open collector of  
an NPN transistor  
Open collector of  
an PNP transistor  
or  
Input  
6
H7ER  
H7ER  
Accessories (Order Separately)  
An H7ER is supplied with a mounting bracket and nut. In addition, the Flush Mounting Adapters shown here allow the H7ER to be fitted to  
existing panel cutouts.  
Y92F-75 FLUSH MOUNTING ADAPTER  
FOR 26  
45 RECTANGULAR CUTOUT  
Must be used with mounting bracket supplied with the Counter  
Two 3.5 dia. mounting holes  
Panel Cutout  
Two M3  
31  
26  
(1.02)  
24.2 22.2  
(1.22)  
26  
45.2  
48.2  
4
45  
63  
63  
72  
(2.48)  
(2.83)  
Y92F-77B FLUSH MOUNTING ADAPTER  
FOR 24.8  
48.8 RECTANGULAR CUTOUT  
Must be used with mounting bracket supplied with the Counter  
Panel cutout  
28.8  
24.8  
(0.98)  
24.2 22.2  
(1.13)  
48.8  
(1.92)  
45.2  
48.2  
53.8  
4
(2.12)  
44.8  
(1.76)  
Y92S-37 WIRE-WRAP TERMINAL  
(SET OF TWO TERMINALS)  
Wire-wrap terminal  
(1 × 1 mm)  
24  
(0.94)  
22  
48  
(1.89)  
48.5  
2
17.1  
5
65.6  
(2.58)  
The wire--wrap terminals have a cross sectional dimension of  
1x1 mm. Select one of three guages of wire from the table at  
right. Also listed in the table is the appropriate wiring hardware  
Wire  
AWG22  
Bit  
Sleeve  
Wrapped  
state  
2-A  
2-B  
1-B  
1-B  
Normal  
AWG24  
AWG26  
1-A  
1-B  
Normal  
Normal  
7
H7ER  
H7ER  
Y92S-36 REPLACEMENT (LITHIUM)  
BATTERY (3 V)  
24.5 dia.  
7.7  
Precautions  
!
WARNING  
BEFORE USE  
This product has a built-in lithium battery. Do not short-circuit  
the+and -- terminals, charge, disassemble, deform, orexpose  
the battery to fire. The battery may explode (break), catch fire,  
or cause liquid leakage.  
An insulation sheet has been inserted to maintain the quality of  
the Totalizer in the event of a long period without use. Be sure to  
remove this sheet before attempting to use the product.  
Remove the insulation sheet and press the Reset Key on the  
front panel of the Counter. (With the H7ER-N,-NV(-H),-NV1(-H),  
models, “0” or “0.0” will be displayed after 1 s.)  
!
Caution  
Donot useany battery otherthanthespecifiedone(Y92S-36).  
Using another battery may cause liquid leakage or breakage,  
resulting in malfunction or injury.  
lation Sheet  
!
Caution  
If a voltage other than the rated one is applied, internal  
elements may be damaged.  
Reset Key  
Do not use the Counter in the following places:  
Locations subject to direct sunlight.  
Locations subject to corrosive gases.  
Locations subject to dust.  
Switch settings on the Counter must be performed before  
mounting it to a control panel.  
Do not use the Counter in locations subject to:  
Severe changes in temperature.  
Condensation as the result of high temperatures.  
MOUNTING PRECAUTIONS FOR FLUSH  
MOUNTING  
Although the operating section is watertight (conforming to  
NEMA4, IP66), rubber packing is provided to avoid water leakage  
through the gap between the Counter and panel cutout. Unless  
this rubber packing is tightly squeezed on, water may permeate  
inside the panel. For this reason, be sure to tighten the screws  
for fixing the Flush Mounting Bracket.  
Screw for the Flush Mounting Bracket  
The wider side must  
face the panel.  
Adapter  
Adapter screw section  
0.5 to 1 mm  
Tighten the screw until the  
distance is within the range  
shown above.  
Panel  
8
H7ER  
H7ER  
RESET INPUT AND COUNT INPUT  
COUNT INPUT OR RESET INPUT TO  
MORE THAN ONE H7ER COUNTER AT  
A TIME  
The H7ER operates using its built-in Battery. If the H7ER is  
connected to a device that has +V and OUT terminals connected  
with a diode as shown in the circuit diagram, the circuit indicated  
by the arrow 1 or 2 will be formed when the device is turned OFF.  
As a result, the H7ER may be reset or count by one. Such  
devices should not be connected to the H7ER.  
PNP/NPN Universal DC Voltage Input  
Count input  
or reset input  
or  
If an excessive voltage is applied to the count or reset input  
terminals, the internal elements may be damaged.  
Ensure that the following voltages are not exceeded:  
PNP/NPN universal voltage input model: 30 VDC  
AC/DC voltage input model:  
or  
Note: H (Reset ON) level must be 4.5 V minimum.  
At count input:  
240 VAC (peak voltage: 338V)  
240 VDC  
4.7 (k)/N + V  
4.7 (k)/N + R  
H =  
At reset input:  
3 VDC (no-voltage input)  
No-voltage input model: 3 VDC  
No-voltage Input  
Do not remove the outer case when voltage is being applied to  
the power supply terminals or to the input terminals.  
or  
The input for the H7E -NFV- is a high-impedance circuit so  
influence from an induced voltage may result in malfunction.  
When the input signal wiring is longer than 10 m (stray  
capacitance of 120 pF/m, at room temperature), a CR filter or a  
bleeder resistor should be connected.  
Note: 1. The leakage current of the transistor used for input  
must be less than 1 µA.  
2. The forward voltage of the diode must be as low as  
possible (i.e., 0.1 V maximum with an I of 20 µA) so  
F
the voltage between terminals 3 and 4 will be 0.5 V  
when the reset input is ON.  
9
H7ER  
H7ER  
INPUT AND POWER SUPPLY  
BATTERY REPLACEMENT  
Do not apply voltage on the Counter if the Counter is a model  
that operates with no-voltage input, or the internal circuit of the  
Counter may be damaged.  
Remove the wiring when replacing the Battery. Do not come in  
contact with any item to which high voltage is being applied.  
Doing so may result in electric shock.  
Do not connect any single input signal in parallel to Counter  
models operating with no-voltage input and those operating with  
voltage input, to avoid malfunction.  
Before changing the Battery, be sure that you are not carrying  
any static electric charge.  
Procedure for replacing the Battery (refer to the diagrams below):  
When connecting a sensor to the Counter that operates with  
no-voltage input, make sure that the sensor has open collector  
output.  
1. Using the tool, pry open the lift-tab on the case. (1)  
2. Pull the body out of its outer case. (2)  
3. Lift the Battery up by the edge and remove it. (3)  
When removing the Battery, do not come in contact with the  
display area or any internal parts.  
Sensor  
4. Wipe the back of the new Battery before inserting it.  
5. Ensure that the + and -- terminals are correctly oriented.  
6. After replacing the Battery, re-insert the body into its case. (4)  
Check that the case is securely held in by the lift-tab.  
7. Press the Reset Key before use (not necessary for  
H7ER-N,-NV,-NV1). (5)  
The operation of the Counter may be affected if the line voltage  
of the power supply exceeds 500 pF (about 10 m, with parallel  
wires of 2 x 2 mm). Keep all wires as short as possible. When  
using shielded wire, stray capacitance may occur.  
When the internal Battery nears expiration, the display may  
flicker.  
When connecting an open collector input from a transistor to the  
Counter that operates with no-voltage input, make sure that the  
leakage current of the transistor is 5 µA maximum.  
(2)  
(1)  
Tool  
When connecting count input from an SSR to the Counter that  
operates with AC/DC voltage input, use OMRON’s G3TA-IA or  
G3TA-ID SSR. Make sure that the leakage current of the SSR is  
0.1 mA maximum or connect a bleeder resistor in parallel to the  
input circuit of the Counter.  
(1)  
(3)  
or  
Leakage current:  
0.1 mA max.  
or  
(4)  
or  
*Bleeder resistor  
The voltage between terminals 1 and 2 must be  
1.5 V maximum when the SSR is OFF.  
(5)  
BACKLIGHT POWER SUPPLY  
EN/IEC STANDARDS  
To reduce variation in the brightness of the backlight when using  
more than one H7ER with a backlight, use the same power  
supply for all the backlights.  
The counter input, reset input, and backlight power supply  
terminals of the no-voltage input or PNP/NPN universal DC  
voltage input models (H7E -N,-N1, H7E -NV(-H),-NV1(-H)) are  
not isolated.  
A SELV power supply conforming to Appendix H of IEC61010-1  
should be used for the counter input, reset input and backlight  
power supply terminals. A SELV power supply is a power supply  
for which the input and output have double or reinforced  
insulation, and for which the output voltage is 30 Vrems with 42.4  
V peak or 60 VDC max. (Only the H7E -NV -H has a  
backlight.)  
When connecting the DC power supply for the backlights, be  
sure to connect the polarities correctly.  
UNIT LABEL FOR TIME COUNTER AND  
TACHOMETER  
A unit label has been packed with the Counter. Use in accordance  
with the application.  
The terminals for counter input and reset input for AC/DC  
multi-voltage input models have basic insulation.  
Connect the reset input terminals to a device that does not have  
exposed current-carrying parts and has basic insulation for  
240 VAC.  
10  
H7ER  
H7ER  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
OMRON ELECTRONICS, INC.  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. M064B--E3--1  
8/99  
Specifications subject to change without notice.  
Printed in U.S.A.  

相关型号:

H7ET

Self-powered Time Counter
ETC

H7ET-N

Self-powered Time Counter
ETC

H7ET-N-B

Self-powered Time Counter
ETC

H7ET-N1

Self-powered Time Counter
ETC

H7ET-N1-B

Self-powered Time Counter
ETC

H7ET-NFV

Self-powered Time Counter
ETC

H7ET-NFV-B

Self-powered Time Counter
ETC

H7ET-NFV1

Self-powered Time Counter
ETC

H7ET-NFV1-B

Self-powered Time Counter
ETC

H7ET-NV

Self-powered Time Counter
ETC

H7ET-NV-B

Analog Circuit
OMRON

H7ET-NV-BH

Self-powered Time Counter
ETC