LY1F-AC100110 [OMRON]

General Purpose Relay – LY;
LY1F-AC100110
型号: LY1F-AC100110
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

General Purpose Relay – LY

文件: 总15页 (文件大小:354K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose Relay – LY  
A Miniature Power Relay  
Equipped with arc barrier.  
Dielectric strength: 2,000 V.  
Built-in diode models added to the LY Series.  
Single-pole and double-pole models are  
applicable to operating coils with ratings of  
100/110 VAC, 110/120 VAC, 200/220 VAC,  
220/240 VAC, or 100/110 VDC).  
Three-pole and four-pole models are  
applicable to operating coils with ratings of  
100/110 VAC, 200/220 VAC, or 100/110 VDC).  
V D E  
RC+  
LR  
Ordering Information  
Open Relays  
Type  
Contact form  
Plug-in/solder  
terminals  
Plug-in/solder  
terminals with  
LED indicator  
PCB terminals  
Upper-mounting  
plug-in/solder  
terminals  
Standard  
SPDT  
LY1  
LY1N  
LY1-0  
LY1F  
DPDT  
LY2  
LY2N  
LY2-0  
LY2F  
DPDT (bifurcated)  
3PDT  
LY2Z  
LY3  
LY2ZN  
LY3N  
LY2Z-0  
LY2ZF  
LY3-0  
LY3F  
4PDT  
LY4  
LY4N  
LY4-0  
LY4F  
With built-in diode  
(DC only)  
SPDT  
LY1-D  
LY2-D  
LY2Z-D  
LY3-D  
LY4-D  
LY1N-D2  
LY2N-D2  
LY2ZN-D2  
DPDT  
DPDT (bifurcated)  
3PDT  
4PDT  
LY4N-D2  
With built-in CR  
(AC only)  
SPDT  
DPDT  
LY2-CR  
LY2Z-CR  
LY2N-CR  
LY2ZN-CR  
DPDT (bifurcated)  
Note: 1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.  
Example: LY2, 6 VAC  
Rated coil voltage  
2. Relays with #187 quick connect terminals are also available with SPDT and DPDT contact. Ask your OMRON  
representative for details.  
3. SEV models are standard Relays excluding DPDT (bifurcated) models.  
4. VDE- or LR- qualifying Relays must be specified when ordering.  
442  
General Purpose Relay – LY  
Accessories (Order Separately)  
Sockets  
Poles  
Front-connecting Socket  
Back-connecting Socket  
Wrapping terminals  
PT08QN  
DIN track/screw terminals  
PTF08A-E, PTF08A  
PTF11A  
Plug-in/solder terminals  
PT08  
PCB terminals  
PT08-0  
1 or 2  
3
4
PT11  
PT14  
PT11QN  
PT11-0  
PT14-0  
PTF14A-E, PTF14A  
PT14QN  
Note: 1. For PTF08-E and PTF14A-E, see “Track Mounted Socket.”  
2. PTFA (-E) Sockets have met UL and CSA standards: UL 508/CSA C22.2.  
Mounting Plates for Sockets  
Socket model  
For 1 Socket  
For 10 Sockets  
For 12 Sockets  
For 18 Sockets  
PYP-18  
PT08  
PT08QN  
PYP-1  
PT11  
PT11QN  
PTP-1-3  
PTP-1  
PTP-12  
PT14  
PTP-10  
PT14QN  
Socket-Hold-down Clip Pairings  
Relay type  
Poles  
Front-connecting Sockets  
Back-connecting Sockets  
Socket model Clip model  
Socket model Clip model  
Standard, bifurcated  
contacts operation  
indicator, built-in diode  
1, 2  
PTF08A-E, PTF08A  
PTF11A  
PYC-A1  
Y92H-3  
PT08(QN), PT08-0  
PT11(QN), PT11-0  
PT14(QN), PT14-0  
PT08(QN), PT08-0  
PYC-P  
3
4
2
PTF14A-E, PTF14A  
PTF08A-E, PTF08A  
CR Circuit  
PYC-1  
Specifications  
Coil Rating  
Single- and Double-pole Relays  
Rated voltage  
Rated current  
Coil  
Resistance  
Coil Induction  
(reference value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
Power  
voltage consumption  
(approx.)  
50 Hz  
60 Hz  
Arm. OFF Arm. ON  
% of rated voltage  
AC 6 V  
12 V  
214.1 mA 183 mA  
106.5 mA 91 mA  
12.2  
46 Ω  
0.04 H  
0.17 H  
0.69 H  
3.22 H  
14.54 H  
19.20 H  
54.75 H  
83.50 H  
0.16 H  
0.73 H  
3.20 H  
10.6 H  
45.6 H  
0.08 H  
0.33 H  
1.30 H  
5.66 H  
24.6 H  
32.1 H  
94.07 H  
136.40 H  
0.33 H  
1.37 H  
5.72 H  
21.0 H  
86.2 H  
80% max. 30% min. 110%  
1.0 to  
1.2 VA  
(60 Hz)  
24 V  
53.8 mA  
25.7 mA  
46 mA  
22 mA  
180Ω  
50 V  
788W  
100/110 V 11.7/12.9 mA 10/11 mA 3,750 Ω  
110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 Ω  
200/220 V 6.2/6.8 mA 5.3/5.8 mA 12,950 Ω  
220/240 V 4.8/5.3 mA 4.2/4.6 mA 18,790 Ω  
0.9 to 1 VA  
(60 Hz)  
DC 6 V  
12 V  
150 mA  
75 mA  
40 Ω  
10% min.  
0.9 W  
160 Ω  
24 V  
48 V  
36.9 mA  
18.5 mA  
650 Ω  
2,600 Ω  
11,000 Ω  
100/110 V 9.1/10 mA  
Note: See notes on the bottom of next page.  
443  
General Purpose Relay – LY  
Three-pole Relays  
Rated voltage  
Rated current  
Coil  
Coil Induction  
Must  
Must  
Max.  
Power  
Resistance  
(reference value)  
operate  
voltage  
release  
voltage  
voltage consumption  
(approx.)  
50 Hz  
60 Hz  
Arm. OFF Arm. ON  
% of rated voltage  
AC 6 V  
12 V  
310 mA  
159 mA  
80 mA  
38 mA  
270 mA  
134 mA  
67 mA  
33 mA  
6.7 Ω  
24 Ω  
0.03 H  
0.12 H  
0.44 H  
2.24 H  
10.5 H  
34.8 H  
0.11 H  
0.45 H  
1.89 H  
8.53 H  
29.6 H  
0.05 H  
0.21 H  
0.79 H  
3.87 H  
18.5 H  
59.5 H  
0.21 H  
0.98 H  
3.87 H  
13.9 H  
54.3 H  
80% max. 30% min. 110%  
1.6 to  
2.0 VA  
(60 Hz)  
24 V  
100 Ω  
410 Ω  
50 V  
100/110 V 14.1/16 mA 12.4/13.7 mA 2,300 Ω  
200/220 V 9.0/10.0 mA 7.7/8.5 mA 8,650 Ω  
DC 6 V  
12 V  
234 mA  
112 mA  
58.6 mA  
28.2 mA  
25.7 Ω  
107 Ω  
10% min.  
1.4 W  
24 V  
48 V  
410 Ω  
1,700 Ω  
8,500 Ω  
100/110 V 12.7/13 mA  
Note: See notes under next table.  
Four-pole Relays  
Rated voltage  
Rated current  
Coil  
Coil Induction  
Must  
Must  
Max.  
Power  
Resistance  
(reference value)  
operate  
voltage  
release  
voltage  
voltage consumption  
(approx.)  
50 Hz  
386 mA  
199 mA  
93.6 mA  
46.8 mA  
60 Hz  
330 mA  
170 mA  
80 mA  
Arm. OFF Arm. ON  
% of rated voltage  
AC 6 V  
12 V  
5 Ω  
0.02 H  
0.10 H  
0.38 H  
1.74 H  
10.5 H  
33.1 H  
0.09 H  
0.39 H  
1.41 H  
6.39 H  
32 H  
0.04 H  
0.17 H  
0.67 H  
2.88 H  
17.3 H  
57.9 H  
0.21 H  
0.84 H  
2.91 H  
13.6 H  
63.7 H  
80% max. 30% min. 110%  
1.95 to  
2.5 VA  
(60 Hz)  
20 Ω  
78 Ω  
350 Ω  
24 V  
50 V  
40 mA  
100/110 V 22.5/25.5 mA 19/21.8 mA 1,600 Ω  
200/220 V 11.5/13.1mA 9.8/11.2 mA 6,700 Ω  
DC 6 V  
12 V  
240 mA  
120 mA  
69 mA  
30 mA  
25 Ω  
10% min.  
1.5 W  
100 Ω  
350 Ω  
1,600 Ω  
6,900 Ω  
24 V  
48 V  
100/110 V 15/15.9 mA  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated  
currents and 15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C.  
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).  
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a  
bleeder resistor if required.  
444  
General Purpose Relay – LY  
Contact Rating  
Relay  
Single Contact  
Bifurcated contacts  
2-pole  
1-pole  
Resistive load  
(cosϕ = 1)  
2-, 3- or 4-pole  
Load  
Inductive load  
(cosϕ = 0.4,  
L/R = 7 ms)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4,  
L/R = 7 ms)  
Resistive load  
Inductive load  
(cosϕ = 0.4,  
L/R = 7 ms)  
(cosϕ = 1)  
Rated Load  
110 VAC 15 A  
24 VDC 15 A  
110 VAC 10 A  
24 VDC 7 A  
110 VAC 10 A  
24 VDC 10 A  
110 VAC 7.5 A  
24 VDC 5 A  
110 VAC 5A  
24 VDC 5 A  
110 VAC 4 A  
24 VDC 4A  
Rated Carry  
Current  
15 A  
10 A  
7 A  
Max. switching 250 VAC  
voltage 125 VDC  
250 VAC  
125 VDC  
250 VAC  
125 VDC  
Max. switching 15 A  
10 A  
7 A  
current  
Max. switching 1,700 VA  
1,100 VA  
170 W  
1,100 VA  
240 W  
825 VA  
120 W  
550 VA  
120 W  
440 VA  
100 W  
power  
360 W  
Failure rate  
100 mA, 5 VDC  
100 mA, 5 VDC  
100 mA, 5 VDC  
(reference value)*  
*Note: P level: λ = 0.1 x 10-6/operation  
60  
Characteristics  
Item  
Contact resistance  
Operate time  
All except Relays with bifurcated contacts  
Relays with bifurcated contacts  
50 mmax.  
25 ms max.  
25 ms max.  
Release time  
Max. operating frequency  
Mechanical: 18,000 operations/hr  
Electrical: 1,800 operations/hr (under rated load)  
Insulation resistance  
Dielectric strength  
100 Mmin. (at 500 VDC)  
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity  
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity  
Vibration resistance  
Shock resistance  
Endurance  
Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)  
Destruction: 1,000 m/s2  
Malfunction: 200 m/s2  
Mechanical: AC: 50,000,000 operations min. (at 18,000 operations/hr)  
DC: 1,00,000,000 operations min. (at 18,000 operations/hr)  
Electrical: Single-, three-, and four-pole: 200,000 operations min.  
(at 1,800 operations/hr under rated load)  
Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)  
Ambient temperature*  
Operating:  
Single- and double-pole standard, bifurcated-contact Relays: –25°C to 55°C (with no icing)  
(–25°C to 70°C if carry current is 4 A or less)  
All other Relays: –25°C to 40°C (with no icing)  
(–25°C to 55°C if carry current is 4 A or less)  
Ambient humidity  
Weight  
Operating: 5% to 85%  
Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g  
Note: 1. The values given above are initial values  
2. The upper limit of 40°C for some Relays is because of the relationship between diode junction temperature and the element  
used.  
445  
General Purpose Relay – LY  
Endurance Under Real Loads (reference only)  
LY1  
Rated voltage  
Load type  
AC motor  
Conditions  
Operating frequency  
Electrical life  
100 VAC  
400 W, 100 VAC single-phase with  
35-A inrush current, 7-A current flow  
ON for 10 s, OFF for 50 s  
50,000 operations  
AC lamp  
300 W, 100 VAC with 51-A  
inrush current, 3-A current flow  
ON for 5 s, OFF for 55 s  
100,000 operations  
25,000 operations  
100,000 operations  
1,500,000 operations  
800,000 operations  
500 W, 100 VAC with 78-A  
inrush current, 5-A current flow  
Capacitor  
(2,000 µF)  
24 VDC with 50-A inrush current,  
1-A current flow  
ON for 1 s, OFF for 6 s  
ON for 1 s, OFF for 2 s  
AC solenoid  
50 VA with 2.5-A inrush current,  
0.25-A current flow  
100 VA with 5-A inrush current,  
0.5-A current flow  
LY2  
Rated voltage  
Load type  
Conditions  
Operating frequency  
Electrical life  
100 VAC  
AC motor  
200 W, 100 VAC single-phase with  
25-A inrush current, 5-A current flow  
ON for 10 s, OFF for 50 s  
200,000 operations  
AC lamp  
300 W, 100 VAC with 51-A  
inrush current, 3-A current flow  
ON for 5 s, OFF for 55 s  
ON for 1 s, OFF for 15 s  
80,000 operations  
10,000 operations  
150,000 operations  
1,000,000 operations  
500,000 operations  
Capacitor  
(2,000 µF)  
24 VDC with 50-A inrush current,  
1-A current flow  
24 VDC with 20-A inrush current,  
1-A current flow  
AC solenoid  
50 VA with 2.5-A inrush current,,  
0.25-A current flow  
ON for 1 s, OFF for 2 s  
100 VA with 5-A inrush current,  
0.5-A current flow  
LY4  
Rated voltage  
Load type  
Conditions  
Operating frequency  
Electrical life  
100 VAC  
AC motor  
200 W, 200 VAC triple-phase with  
5-A inrush current, 1-A current flow  
ON for 10 s, OFF for 50 s  
500,000 operations  
750 W, 200 VAC triple-phase with  
18-A inrush current, 3.5 A current flow  
70,000 operations  
50,000 operations  
5,000 operations  
AC lamp  
300 W, 100 VAC with 51-A  
inrush current, 3-A current flow  
ON for 5 s, OFF for 55 s  
ON for 1 s, OFF for 15 s  
ON for 1 s, OFF for 2 s  
ON for 1 s, OFF for 2 s  
Capacitor  
(2,000 µF)  
24 VDC with 50-A inrush current,  
1-A current flow  
24 VDC with 20-A inrush current,  
1-A current flow  
200,000 operations  
1,000,000 operations  
500,000 operations  
AC solenoid  
50 VA with 2.5-A inrush current,  
0.25-A current flow  
100 VA with 5-A inrush current,  
0.5-A current flow  
446  
General Purpose Relay – LY  
Approved Standards  
UL 508 Recognitions (File No. 41643)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
1
2
6 to 240 VAC  
6 to 125 VDC  
15 A, 30 VDC (Resistive)  
15 A, 240 VAC (General use)  
TV-5, 120 VAC  
6 x 103  
25 x 103  
1/2 HP, 120 VAC  
15 A, 28 VDC (Resistive)  
15 A, 120 VAC (Resistive)  
12 A, 240 VAC (General use)  
1/2 HP, 120 VAC  
6 x 103  
25 x 103  
6 x 103  
TV-3, 120 VAC  
3 and 4  
10 A, 30 VDC (Resistive)  
10 A, 240 VAC (General use)  
1/3 HP, 240 VAC  
CSA 22.2 No. 14 Listings (File No. LR31928)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
1
6 to 240 VAC  
6 to 125 VDC  
15 A, 30 VDC (Resistive)  
15 A, 120 VAC (General use)  
1/2 HP, 120 VAC  
6 x 103  
25 x 103  
TV-5, 120 VAC  
2
15 A, 30 VDC (Resistive)  
15 A, 120 VAC (Resistive)  
1/2 HP, 120 VAC  
6 x 103  
TV-3, 120 VAC  
3 and 4  
10 A, 30 VDC (Resistive)  
10 A, 240 VAC (General use)  
SEV Listings (File No. D3,31/137)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
1
6 to 240 VAC  
15 A, 24 VDC  
6 x 103  
6 to 125 VDC  
15 A, 220 VAC  
2 to 4  
10 A, 24 VDC  
10 A, 220 VAC  
TÜV (File No. R9251226) (IEC255)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
1 to  
4
6 to 125 VDC  
LY1, LY1-FD  
100 x 103  
6 to 240 VAC  
15 A, 110 VAC (cosϕ = 1)  
10 A, 110 VAC (cosϕ = 0.4)  
LY2, LY2-FD, LY3, LY3-FD,  
LY4, LY4-FD  
10 A, 110 VAC (cosϕ = 1)  
7.5 A, 110 VAC (cosϕ = 0.4)  
VDE Recognitions (No. 9903UG and 9947UG)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
1
6, 12, 24, 50, 110, 220 VAC  
6, 12, 24, 48, 110 VDC  
10 A, 220 VAC (cosϕ = 1)  
7 A, 220 VAC (cosϕ = 0.4)  
10 A, 28 VDC (L/R = 0 ms)  
7 A, 28 VDC (L/R = 7 ms)  
200 x 103  
2
7 A, 220 VAC (cosϕ = 1)  
4 A, 220 VAC (cosϕ = 0.4)  
7 A, 28 VDC (L/R = 0 ms)  
4 A, 28 VDC (L/R = 7 ms)  
447  
General Purpose Relay – LY  
Approved Standards (cont.)  
LR Recognitions (No. 563KOB-204523)  
No. of poles  
Coil ratings  
Contact ratings  
2, 4  
6 to 240 VAC  
6 to 110 VDC  
7.5 A, 230 VAC (PF0.4)  
5 A, 24 VDC (L/R=7 ms)  
Engineering Data  
LY1  
Maximum Switching Power  
Endurance  
AC resistive load  
15  
10  
5
Life: 200,000  
operations  
AC  
(cosφ =  
10,000  
5,000  
0.4)  
110 VAC resistive load  
24 VDC resistive load  
1
DC  
L/R = 7 ms  
0.5  
1,000  
500  
DC resistive load  
24 VDC (L/  
R = 7ms)  
110 VAC (cosφ = 0.4)  
0.1  
100  
10  
100  
500 1,000  
0
2
4
6
8
10 12 14 16 18 20  
Switching voltage (V)  
Switching current (A)  
LY2  
Maximum Switching Power  
Endurance  
AC resistive load  
10  
5
Life: 500,000  
operations  
AC  
(cosφ =  
0.4)  
1,0000  
5,000  
24 VDC resistive load  
110 VAC resistive load  
1
0.5  
DC  
L/R = 7 ms  
1,000  
500  
DC resistive load  
110 VAC (cosφ = 0.4)  
0.1  
24 VDC (L/R = 7ms)  
100  
0
2
4
6
8
10 12 14 16 18 20  
10  
100  
500 1,000  
Switching current (A)  
Switching voltage (V)  
LY3 and LY4  
Maximum Switching Power  
Endurance  
AC resistive load  
10  
5
Life: 200,000  
operations  
AC  
(cosφ =  
0.4)  
1,0000  
5,000  
24 VDC resistive load  
110 VAC resistive load  
1
DC  
L/R = 7 ms  
1,000  
500  
0.5  
110 VAC (cosφ = 0.4)  
DC resistive load  
0.1  
100  
24 VDC (L/R = 7ms)  
500 1,000  
10  
100  
0
2
4
6
8
10 12 14 16 18 20  
Switching current (A)  
Switching voltage (V)  
448  
General Purpose Relay – LY  
LY2Z  
LY2Z  
Endurance  
Maximum Switching Power  
AC resistive load  
10  
5
AC  
(cosφ = 0.4)  
24 VDC resistive load  
10,000  
5,000  
110 VAC resistive load  
DC resistive load  
110 VAC (cosφ = 0.4)  
1
1,000  
500  
0.5  
DC  
L/R = 7 ms  
24 VDC (L/R = 7ms)  
100  
0
Life: 500,000 operations  
0
2
4
6
8
10  
10  
50 100  
500 1,000  
Switching voltage (V)  
Switching current (A)  
Dimensions  
Note: All units are in millimetres unless otherwise indicated.  
Relays with Solder/Plug-in Terminals  
LY1  
LY1N (-D2)  
LY1-D  
0.5  
Eight, 2-dia. holes  
28 max.  
5
3
21.5  
max.  
6.4  
36 max.  
Terminal Arrangement/Internal Connections (Bottom View)  
LY1N  
LY1  
LY1-D  
DC Model  
AC Model  
LY1N-D2  
Note: The DC models have polarity.  
449  
General Purpose Relay – LY  
LY2  
LY2Z  
LY2-D  
LY2N  
LY2Z-D  
LY2ZN  
LY2N-D2 LY2ZN-D2  
Terminal Arrangement/Internal  
Connections (Bottom View)  
LY2(Z)-D  
LY2(Z)  
0.5  
Eight, 3-dia. holes  
5
28 max.  
3
21.5 max.  
6.4  
36 max.  
LY2(Z)N  
LY2(Z)N-D2  
DC Model  
AC Model  
Note: The DC models have polarity.  
LY3  
LY3N  
LY3-D  
0.5  
28 max.  
5
3
31.5 max.  
36.5 max.  
6.4  
Eleven, 3-dia. holes  
Terminal Arrangement/Internal Connections (Bottom View)  
LY3-D  
LY3N  
LY3  
DC Model  
AC Model  
Note: The DC models have polarity.  
450  
General Purpose Relay – LY  
LY4  
LY4N  
LY4-D LY4N-D2  
Terminal Arrangement/Internal Connections  
(Bottom View)  
LY4  
LY4-D  
0.5  
28 max.  
5
3
41.5 max.  
Fourteen,  
3-dia. holes  
36 max.  
6.4  
LY4N  
LY4N-D2  
DC Model  
AC Model  
Note: The DC models have polarity.  
LY2-CR  
Terminal Arrangement/Internal Connections  
(Bottom View)  
LY2Z-CR  
LY2N-CR  
LY2ZN-CR  
LY2(Z)N-CR  
LY2(Z)-CR  
0.5  
Eight, 3-dia.  
holes  
28 max.  
5
3
CR Element  
21.5  
max.  
53 max.  
C: 0.033 µF  
R: 120 Ω  
6.4  
Model: LY2N-CR  
Relays with PCB Terminals  
LY1-0 LY3-0  
LY2-0 LY4-0  
PC Board Holes (Bottom View)  
14.2  
10  
14.2  
10  
10 10 10  
10 10  
0.5  
4.1  
5.5  
28 max.  
5.75  
4.6  
2
13.15  
7.15  
1
21.5  
max.  
36 max.  
4.5 (see note 2)  
5.3  
3.4  
5.3  
3.4  
Fourteen,  
2.5-dia.  
holes  
Eleven,  
2.5-dia.  
holes  
Five,  
Eight,  
2.5-dia.  
holes  
2.5-dia.  
holes  
Note: 1. The above model is the LY2-0.  
2. This figure is 6.4 for the LY1-0  
Note: 1. The tolerance for the above figures is 0.1 mm.  
2. Besides the terminals, some part of the LY1-0  
carries current. Due attention should be paid when  
mounting the LY1-0 to a double-sided PC board.  
451  
General Purpose Relay – LY  
Upper Mounting relays  
LY1F  
LY2F  
Mounting Holes  
22.5 max.  
2
0.5  
44  
max.  
29  
max.  
38  
38 0.1  
5
3
Eight, 2-dia.  
holes (see note)  
Two, 3.5-dia.  
holes (or Two  
M3 holes)  
35.5 max.  
6.4  
3.5  
Note: 1. Eight 3-dia. holes should apply to  
the LY2F model.  
LY3F  
32 max.  
2
3.5  
0.5  
28.5  
max.  
38 0.1  
38  
44 max.  
5
3
Eleven,  
3-dia. holes  
Two, 3.5-dia. holes  
(or two, M3 holes)  
36 max.  
6.4  
LY4F  
Mounting holes  
41.5 max.  
3.5  
Two, 3.5 dia. holes (or  
two, M3 holes)  
2
0.5  
5
44  
max.  
28  
max.  
38  
38 0.1  
Fourteen,  
3-dia. holes  
28 0.1  
28  
3
35.5 max.  
6.4  
452  
General Purpose Relay – LY  
Mounting Height with Socket  
The following Socket heights should be maintained.  
Back-connecting  
Front-connecting  
LY  
40 (57)  
LY  
67 (84)  
Note: 1. The PTF@A (-E) can be track-mounted or screw-mounted.  
71 (see note)  
2. For the LY@-CR (CR circuit built-in type) model, this figure  
should be 88.  
PT@  
PTF@A (-E)  
Sockets  
PTF08A-E  
PTF11A  
PTF14A-E  
PT08  
PT11  
PT14  
PT08QN  
PT14-0  
PT11QN  
PT14QN  
PT08-0  
PT11-0  
Mounting Plates for Back-connecting  
PYP-1  
PTP-1-3  
PTP-1  
PYP-18  
Two, 3.4-dia. holes  
49  
492  
59  
R5  
7.7  
42 0.1 49  
7.7  
42 0.1  
17 x 27.4 = 465.8 0.6  
21.6  
Four,  
3.4-dia.  
holes  
4.5  
3.4  
72 elliptical holes  
5.1  
42  
49  
42 0.1 49  
R1.7  
7.7  
42 0.1 49  
28  
R5  
52 0.1  
t=1.6  
Four, 3.4-dia. holes  
t=1.6  
t=1.6  
21.6  
17 x 27.4 = 465.8 0.6  
17 x 27.4 = 465.8 0.6  
t=1.6  
PTP-10  
7.4  
PTP-12  
40 elliptical holes  
7.7  
9 x 49.4 = 444.6 0.6  
48 elliptical holes  
11 x 39.4 = 433.4 0.6  
49  
42 0.1  
7.7  
42 0.1 49  
R1.7  
3.4  
3.4  
4.5  
1.1  
Twelve, square holes  
t=1.6  
4.5  
R2.25  
7.4  
9 x 49.4 = 444.6 0.6  
11 x 39.4 = 433.4 0.6  
11 x 39.4 = 433.4 0.6  
492  
9 x 49.4 = 444.6 0.6  
492  
23.7  
29.3  
t=1.6  
453  
General Purpose Relay – LY  
Hold-down Clips  
Hold-down clips are used to hold Relays to Sockets and prevent them from coming loose due to vibration or shock.  
Used with Socket  
Used with Socket  
mounting plate  
For CR circuit built-in Relay  
PYC-A1  
PYC-S  
PYC-1  
Y92H-3  
PYC-P  
Precautions  
Connections  
Do not reverse polarity when connecting DC-operated Relays  
with built-in diodes or indicators.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETRES.  
To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
CAT. No. J002-E2-10  
454  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if  
specified) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL  
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR  
STRICT LIABILITY.  
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the product.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government regulations.  
• Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix  
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased product.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
ERRORS AND OMISSIONS  
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent  
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
COPYRIGHT AND COPY PERMISSION  
This catalog shall not be copied for sales or promotions without permission.  
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this  
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.  
Cat. No. J002-E2-10  
2007.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2007 All Rights Reserved.  
Mouser Electronics  
Authorized Distributor  
Click to View Pricing, Inventory, Delivery & Lifecycle Information:  
Omron:  
LY3-AC120 LY2-0-DC1011/00 LY2-0-AC220/240 LY2F-AC100/110 LY2N-AC24 LY2N-DC12 LY4-AC240 LY4N-  
AC120 LY2Z-DC24 LY3-0-AC120 LY1-0-DC12 LY2-0-DC12 LY1-AC110/120 LY4F-AC120 LY3F-DC12 LY1F-  
DC12 LY4F-DC12 LY2F-DC12 LY2F-AC110/120 LY2F-AC220/240 LY1-0-AC110/120 LY2-0-AC110/120 LY2N-  
DC24 LY1N-DC24 LY4N-DC24 LY4-DC24 LY4-DC48 LY4-DC12 LY1-0-DC24 LY4-0-DC24 LY3-DC24 LY2-0-  
DC24 LY3-AC24 LY4-AC24 LY3-DC12 LY4F-DC24 LY2F-DC24 LY3F-DC24 LY1F-DC24 PTF08A-E LY1-DC24  
LY1-DC12 LY2-0-AC24 LY1-0-AC24 LY2-AC220/240 LY3N-AC120 LY1-AC24 LY1F-AC110/120 LY3F-AC120  
LY2-D-DC12 LY2N-D2-DC24 LY2-AC110/120 LY2-AC24 LY4-AC120 LY2-DC12 LY2F-AC24 LY1F-AC24 LY3F-  
AC24 LY4F-AC24 LY2-DC24 LY2-AC6 LY2-AC100/110 LY2-AC200/220 LY2-0-AC100/110 LY2-0-AC200/220  
LY2N-AC6 LY2N-AC12 LY2N-AC100/110 LY2N-AC200/220 LY2F-AC12 LY2F-AC200/220 LY2Z-AC100/110 LY2Z-  
AC110/120 LY2ZN-AC100/110 LY2ZF-AC24 LY2-DC6 LY2-DC100/110 LY2-0-DC6 LY2-0-DC48 LY2N-DC6  
LY2N-DC48 LY2N-DC100/110 LY2Z-DC12 LY2Z-0-DC24 LY2ZN-DC24 LY2Z-D-DC24 LY1-AC12 LY1F-AC12  
LY1N-AC24 LY1F-AC100/110 LY1N-AC110/120 LY1-AC200/220 LY1F-AC200/220 LY1-AC220/240 LY1-0-  
AC220/240 LY1N-AC220/240 LY1F-AC220/240 LY1N-DC12 LY1-D-DC12 LY1-D-DC24  

相关型号:

LY1F-AC110

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY1F-AC110/120

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY1F-AC12

General Purpose Relay – LY
OMRON

LY1F-AC120

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY1F-AC200/220

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY1F-AC200220

General Purpose Relay – LY
OMRON

LY1F-AC220

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY1F-AC220/240

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY1F-AC220240

General Purpose Relay – LY
OMRON

LY1F-AC24

POWER/SIGNAL RELAY, SPDT, MOMENTARY, 1200mW (COIL), 15A (CONTACT), 24VDC (CONTACT), PANEL MOUNT
OMRON

LY1F-AC240

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY1F-DC100/110

Power/Signal Relay, SPDT, Momentary, 0.01A (Coil), 110VDC (Coil), 900mW (Coil), 15A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Panel Mount,
OMRON