LY4F-AC240
更新时间:2024-09-18 17:58:11
品牌:OMRON
描述:Power/Signal Relay, 4PDT, Momentary, 2500mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
LY4F-AC240 概述
Power/Signal Relay, 4PDT, Momentary, 2500mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount 功率/信号继电器
LY4F-AC240 规格参数
是否无铅: | 不含铅 | 是否Rohs认证: | 符合 |
生命周期: | Active | Reach Compliance Code: | unknown |
ECCN代码: | EAR99 | HTS代码: | 8536.41.00.20 |
Factory Lead Time: | 14 weeks | 风险等级: | 5.56 |
其他特性: | COIL OPERATE VOLTAGE(AC): 192 V, COIL RELEASE VOLTAGE(AC); 72 V | 主体宽度: | 41.4 mm |
主体高度: | 35.56 mm | 主体长度或直径: | 43.94 mm |
线圈电流(交流)最大值: | 0.011 A | 线圈功率: | 2500 mW |
线圈电阻: | 9000 Ω | 最大线圈电压(交流): | 240 V |
线圈/输入电源类型: | AC | 触点(交流)最大额定R负载: | 10A@110VAC |
最大触点电流(交流): | 10 A | 最大触点电流(直流): | 10 A |
触点(直流)最大额定R负载: | 10A@24VDC | 最大触点电压(交流): | 110 V |
最大触点电压(直流): | 24 V | 触点/输出电源类型: | AC/DC |
安装特点: | PANEL MOUNT | 工作时间: | 25 ms |
最高工作温度: | 70 °C | 最低工作温度: | -40 °C |
物理尺寸: | 43.94mm x 41.4mm x 35.56mm | 参考标准: | CSA; LR; SEMKO; SEV; UL; VDE |
继电器动作: | MOMENTARY | 继电器功能: | 4PDT |
继电器类型: | POWER/SIGNAL RELAY | 释放时间: | 25 ms |
表面贴装: | NO | 端接类型: | SOLDER |
Base Number Matches: | 1 |
LY4F-AC240 数据手册
通过下载LY4F-AC240数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载General Purpose Relay
LY
• Arc barrier equipped.
• High dielectric strength (2,000 VAC).
• Long dependable service life assured by Ag-Alloy contacts.
• Choose models with single or bifurcated contacts,
LED indicator, diode surge suppression,
push-to-test button, or RC circuit.
• All models meet UL and CSA
approvals; VDE, LR, and SEV
approved versions are available.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., LY1-DC6).
Type
Terminal
Contact
form
Model
Single contact
Bifurcated contact
Upper Lower
Standard
bracket
mounting
Upper
mounting
bracket
Lower
mounting
bracket
Standard
bracket
mounting
bracket
mounting
bracket
mounting
Standard
Plug-in/solder
PCB
SPDT
LY1
LY1F
LY2F
LY3F
LY4F
—
LY1S
—
—
—
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
4PDT
SPDT
DPDT
SPDT
DPDT
LY2
LY2S
LY3S
LY4S
—
LY2Z
LY2ZF
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
LY2ZS
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
LY3
—
LY4
—
LY1-0
—
LY2-0
—
—
LY2Z-0
LY3-0
—
—
—
LY4-0
—
—
—
LED indicator
Plug-in/solder
LY1N
—
—
—
LY2N
—
—
LY2ZN
LY3N
—
—
—
LY4N
—
—
—
Diode surge
suppression
LY1-D
LY2-D
LY3-D
LY4-D
LY1N-D2
LY2N-D2
LY4N-D2
LY1-CR
LY2-CR
LY1N-CR
LY2N-CR
—
—
—
—
—
LY2Z-D
—
—
—
—
—
—
LED indicator
and diode surge
suppression
—
—
—
—
—
LY2ZN-D2
—
—
—
RC circuit
—
—
—
—
—
LY2Z-CR
—
LED indicator
and RC circuit
—
—
—
—
LY2ZN-CR
Note: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative.
2. To order connecting sockets and mounting tracks, see “Accessories” section.
718
General Purpose Relay LY
Type
Terminal
Contact
form
Model
Single contact
Bifurcated contact
Upper Lower
Standard
bracket
mounting
Upper
mounting
bracket
Lower
mounting
bracket
Standard
bracket
mounting
bracket
mounting
bracket
mounting
Push-to-test
button
Plug-in/solder
Plug-in/solder
SPDT
LY1l4
—
—
—
—
—
—
—
—
—
—
DPDT
3PDT
4PDT
DPDT
4PDT
LY2l4
—
—
—
—
—
LY2Zl2
—
—
—
—
—
—
—
—
—
—
—
LY3l4
LY4l4
—
LED indicator and
push-to-test button
LY2l4N
LY4l4N
LY2Zl2N
—
Note: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative.
2. To order connecting sockets and mounting tracks, see “Accessories” section.
ꢀ Accessories
Connecting Sockets
To Order: Select the appropriate part numbers for sockets, clips, and mounting tracks (if required) from the following charts.
Track Mounted Sockets
Relay
Socket*
Relay hold-down clip
Standard RC circuit
Mounting track
SPDT
DPDT
3PDT
4PDT
PTF08A-E
PYC-A1
Y92H-3
PFP-100N/PFP-50N &
PFP-M or PFP-100N2
PFP-S (Option spacer)
PTF11A
PTF14A-E
* Track mounted socket can be used as a front connecting socket.
Back Connecting Sockets
Relay
Solder
terminal
socket
Wire wrap
terminal
socket
Relay hold-down clip
Standard Push-to-test RC circuit Mtg. plate
PYC-P PYC-P2 PYC-1 PYC-S
Socket Mounting Plate
10 12
1
18
SPDT
PT08
PT08QN
PYP-1
–
–
PYP-18
DPDT
3PDT
4PDT
PT11
PT14
PT11QN
PT14QN
PTP-1-3
PTP-1
–
PTP-12
–
–
PTP-10
–
Note: Types PYP-18, PTP-12 and PTP-10 may be cut to any desired length.
Relay PC terminal socket
Relay hold-down clip
Push-to-test
Standard
RC circuit
SPDT
DPDT
3PDT
4PDT
PT08-0
PYC-P
PYC-P2
PYC-1
PT11-0
PT14-0
General Purpose Relay LY
719
Specifications
ꢀ Contact Data
Load
Single contact
Bifurcated contact
DPDT
SPDT
DPDT, 3PDT, 4PDT
Resistive load
Inductive load
Resistive load
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
Resistive load
Inductive load
(p.f. = 0.4)
(L/R = 7 ms)
(p.f. = 1)
(p.f. = 0.4)
(p.f. = 1)
(p.f. = 1)
(L/R = 7 ms)
Rated load
15 A at 110 VAC
15 A at 24 VDC
10 A at 110 VAC
7 A at 24 VDC
10 A at 110 VAC
10 A at 24 VDC
7.5 A at 110 VAC
5 A at 24 VDC
5 A at 110 VAC
5 A at 24 VDC
4 A at 110 VAC
4 A at 24 VDC
Contact material Ag-Alloy
Carry current
15 A
10 A
7 A
7 A
Max. operating
voltage
250 VAC
125 VDC
15 A
Max. operating
current
10 A
Max. switching
capacity
1,700 VA
360 W
1,100 VA
170 W
1,100 VA
240 W
830 VA
120 W
550 VA
440 VA
100 W
120 W
Min. permissible 100 mA, 5 VDC
10 mA, 5 VDC
load
ꢀ Coil Data
1- and 2-pole Types – AC
Rated
Rated current (mA)
50 Hz 60 Hz
214.10
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
Maximum
voltage
Power
consumption
(VA, W)
voltage (V)
voltage
Armature
OFF
Armature
ON
(% of rated voltage)
6
183
91
12.20
46
0.04
0.08
0.33
1.30
5.66
80% max.
30% min.
110%
Approx.
1.00 to 1.20
(60 Hz)
12
106.50
53.80
25.70
0.17
24
46
180
0.69
50
22
788
3.22
100/110
110/120
200/220
220/240
11.70/12.90 10/11
3,750
4,430
12,950
18,790
14.54
19.20
54.75
83.50
24.60
32.10
94.07
136.40
Approx.
0.90 to 1.10
(60 Hz)
9.90/10.80
6.20/6.80
4.80/5.30
8.40/9.20
5.30/5.80
4.20/4.60
1- and 2-pole Types – DC
Rated
Rated current (mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(VA, W)
voltage (V)
Armature
OFF
Armature
ON
(% of rated voltage)
80% max. 10% min. 110%
6
150
75
40
0.16
0.33
Approx.
0.90
12
160
0.73
1.37
5.72
21
24
36.90
650
3.20
48
18.50
2,600
11,000
10.60
45.60
100/110
9.10/10
86.20
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for AC rated
current, and 15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Class B coil insulation is available.
720
General Purpose Relay LY
3-pole Type – AC
Rated
voltage (V)
Rated current (mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(VA, W)
50 Hz
310
60 Hz
270
Armature Armature
(% of rated voltage)
30% min. 110%
OFF
ON
6
6.70
24
0.03
0.05
0.21
0.79
3.87
80% max.
Approx.
1.60 to 2.00
(60 Hz)
12
159
80
134
67
0.12
24
100
410
0.44
50
38
33
2.24
100/110
120
15.90/18.30 13.60/15.60 2,300
10.50
11.50
34.80
38.60
18.50
20.60
59.50
74.60
17.30
10.50/11.60 9.00/9.90
9.40
14.8
2,450
8,650
10,400
200/220
240
8
3-pole Type – DC
Rated
voltage
(V)
Rated current (mA)
Coil
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(VA, W)
resistance
(Ω)
Armature Armature
(% of rated voltage)
OFF
ON
6
234
25.70
107
0.11
0.21
0.98
3.87
80% max.
10% min.
110%
Approx.
1.40
12
112
0.45
1.89
8.53
29.60
24
58.60
28.20
12.70/13
410
48
1,700
8,500
13.90
54.30
100/110
4-pole Type – AC
Rated
Rated current (mA)
50 Hz 60 Hz
386 330
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
Maximum
voltage
Power
consumption
(VA, W)
voltage (V)
voltage
Armature Armature
(% of rated voltage)
OFF
ON
6
5
0.02
0.04
0.17
0.67
2.88
80% max.
30% min.
110%
Approx.
1.95 to 2.50
(60 Hz)
12
199
170
80
20
0.10
24
93.60
46.80
78
0.38
50
40
350
1,800
2,200
1.74
100/110
120
22.50/25.50 19/21.80
19.00 16.40
10.50
9.30
17.30
19
200/220
240
11.50/13.10 9.80/11.20 6,700
11.00 9.50 9,000
33.10
33.20
57.90
63.40
4-pole Type – DC
Rated
voltage (V)
Rated current (mA)
Coil
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
Maximum
voltage
Power
consumption
(VA, W)
resistance
voltage
(Ω)
Armature Armature
(% of rated voltage)
OFF
ON
6
240
25
0.09
0.21
0.84
2.91
80% max.
10% min.
110%
Approx.
1.50
12
120
100
0.39
1.41
6.39
32
24
69
350
48
30
1,600
6,900
13.60
63.70
100/110
15/15.90
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for AC rated
current, and 15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Class B coil insulation is available.
General Purpose Relay LY
721
ꢀ Characteristics
Contact resistance
50 mΩ max.
Operate time
25 ms max.
Release time
25 ms max.
Operating frequency
Mechanically
18,000 operations/hour
Under rated load
1,800 operations/hour
Insulation resistance
Dielectric strength
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Vibration
Shock
Mechanical durability
Malfunction durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s2 (approx. 100 G)
Mechanical durability
200 m/s2 (approx. 20 G)
Malfunction durability
Operating
Ambient temperature
Humidity
-40° to 70°C (-40° to 158°F) (over 4A carry currents 55°C max.)
35 to 85% RH
Service Life
Mechanically
Electrically
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
Weight
SPDT, DPDT: Approx. 40 g (1.41 oz), 3PDT: Approx. 50 g (1.76 oz)
4PDT: Approx. 70 g (2.47 oz)
Note: Data shown are of initial value.
ꢀ Characteristic Data
Maximum switching capacity
LY1
LY2
LY3, LY4
LY2Z
Rated operating voltage (V)
Rated operating voltage (V)
Rated operating voltage (V)
Rated operating voltage (V)
Electrical service life
LY1
LY2
LY3, LY4
LY2Z
Switching current (A)
Switching current (A)
Switching current (A)
Switching current (A)
722
General Purpose Relay LY
Dimensions
Unit: mm (inch)
ꢀ Relays
LY1
Terminal
LY2
Terminal
arrangement
(Bottom view)
arrangement
(Bottom view)
LY3
Terminal
LY4
Terminal
arrangement
(Bottom view)
arrangement
(Bottom view)
LY1-0, LY2-0, LY3-0, LY4-0
Mounting holes for LY1-0, LY2-0, LY3-0, LY4-0
(Bottom view)
Note: The above drawing shows LY2-0. With LY1-0,
dimension “*” should read as eight 6.35 (.25).
SPTD
DPDT
3PDT
4PDT
LY1F, LY2F
Mounting
holes
LY3F
Mounting
holes
Note: The above drawing shows LY1F. With LY2F, dimension “*”
should read as eight 3.05 mm (0.12 in) dia. holes.
General Purpose Relay LY
723
LY4F
Mounting holes
LY1S, LY2S
Round hole
Rectangular hole
Note: The above drawing shows LY2S-US. With LY1S-US, dimension “*”
should read as eight 2.03 mm (0.08 in) dia. holes.
LY3S
Round hole
Rectangular hole
LY4S
Round hole
Rectangular hole
724
General Purpose Relay LY
ꢀ Accessories
Unit: mm (inch)
Track mounted sockets (UL File No. E87929) (CSA Report No. LR31928)
PTF08A
(see note 3)
Terminal arrangement/
mounting holes
(Top view)
PTF11A
Terminal arrangement/
mounting holes
(Top view)
Track mounting sockets (UL File No. E87929) (CSA Report No. LR31928)
PTF14A
(see note 3)
Terminal arrangement/
mounting holes
(Top view)
Mounting height of
relay with socket
(Applies to all PTF❏A sockets)
Note: 1. UL/CSA does not apply to wire wrap (Q) type sockets.
2. Values in brackets for LY❏CR.
3. PTF08A-E and PTF14A-E = touch safe screws. Height = 33 mm max.
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT08
Terminal arrangement/
PT11
Terminal arrangement/
(Bottom view)
(Bottom view)
General Purpose Relay LY
725
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT14
Terminal arrangement
Mounting height of relay with socket
(Bottom view)
(Applies to all PT sockets)
PT
Note: Values in brackets for LY❏CR.
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT08QN
PT11QN
PT14QN
Panel cut-out and terminal
arrangement are the same
as Type PT08.
Panel cut-out and terminal
arrangement are the same
as Type PT11.
Panel cut-out and terminal
arrangement are the same
as Type PT14.
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT08-0
Mounting holes
PT11A
Mounting holes
Terminal arrangement is
the same as Type PT08.
(Bottom view)
Terminal arrangement is
the same as Type PT11.
(Bottom view)
Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)
PT14-0
Mounting holes
Terminal arrangement is
the same as Type PT14.
(Bottom view)
726
General Purpose Relay LY
Unit: mm (inch)
Relay hold-down clips
PYC-A1
PYC-S
PYC-P
For PTF❏A socket
For relay mounting plates
(Applicable to Type PYP-1 and PYP-18
socket mounting plates only.)
For PT❏ socket
Relay hold-down clips
PYC-P2
Y92H-3
PYC-1
For push-to-test button type with
PT❏ socket
For RC circuit type
For RC circuit type
Mounting track/end plate/spacer
PFP-100N/PFP-50N mounting track
PFP-M end plate
General Purpose Relay LY
727
PFP-100N2 mounting track
PFP-S spacer
*
This dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in the case of PFP-50N.
** L = Length
PFP-50N
................... L = 497.84 mm (19.60 in)
PFP-100N ................... L = 990.60 mm (39.00 in)
PFP-100N2 ................... L = 990.60 mm (39.00 in)
*** A total of twelve 24.89 x 4.57 mm (0.98 x 0.18 in) elliptic holes are provided, with six holes cut from each end of the track at a pitch
of 9.91 (0.39) between holes.
Socket mounting plates [t=1.52 (.06)]
Number of socket specs.
Socket needed
PT08, PT08QN
PT11, PT11QN
PT14, PT14QN
PTP-10
1
10
12
18
PYP-1
PTP-1-3
PTP-1
PTP-12
–
–
PYP-18
–
PTP-1-2
_
PTP-10
–
–
PYP-1
PTP-1-3
PTP-1
PYP-18
PTP-10
PTP-12
728
General Purpose Relay LY
ꢀ Relay Options
LED Indicator
Specifications and dimensions same as the Standard Type with the following exception. With the LED indicator type, the rated current is approxi-
mately 0 to 5.0 mA higher than the Standard Type.
Terminal arrangement/Internal connections (Bottom view)
LY2N
DC coil rating type
AC coil rating type
1
3
2
4
1
3
2
4
5
7
6
8
5
7
6
8
Note: 1. The coil terminals 10 and 11 of Type LY3N become (-) and (+) and terminals 13 and 14 of Type LY4N become (-) and (+), respectively.
2. Pay special attention to the polarities when using the DC type.
Diode Surge Suppression
Specifications and dimensions same as the Standard Type with the following exception. Ambient operating temperature: -25° to 40°C
(-13° to 104°F)
Without Diode
With Diode
Terminal arrangement/Internal connections (Bottom view)
LY2(N)-D(2)
LY2-D
LY2N-D2
LY2N-D2
6, 12, 24, 48
100/110 VDC
6, 12, 24, 48 VDC
100/110 VDC
Note: 1. Pay special attention to the polarities when using the DC type.
2. The release time is somewhat longer, but satisfies the standard specifications of 25 ms.
3. The reverse-breakdown voltage of the diode is 1,000 VDC.
4. Available on DC versions only.
General Purpose Relay LY
729
ꢀ Relay Options
RC Circuit
Specifications and dimensions same as the Standard Type with the following exceptions.
Characteristic Data
Without RC circuit
With RC circuit
LY1-CR, LY2(Z)-CR
Terminal arrangement/Internal connections (Bottom view)
LY1-CR
LY2(Z)-CR
Note: 1. The above drawing shows LY2(Z)-CR. With LY1-CR, “*” should read eight 2.03 mm (0.08 in) dia. holes.
2. Available on AC versions only.
Push-to-test Button
Specifications and dimensions same as the Standard Type with the following exceptions.
LY❏12
LY112, LY212
Note: Type LY112 has the same dimensions and appearances as Type LY212 shown except that dimensions “*” is 2.03 mm (0.08 in) dia. holes.
LY312
LY412
730
General Purpose Relay LY
ꢀ Approvals
UL Recognized Type (File No. E41643)
Type
Contact form
SPDT
Coil ratings
6 to 240 VAC
6 to 120 VDC
Contact ratings
LY❏
LY❏
15 A, 240 VAC (Inductive)
15 A, 28 VDC (Resistive)
TV-5 (ACTV)
1/2 HP, 120 VAC (Motor)
13 A, 120 VAC (Resistive)
12 A, 240 VAC (Inductive)
10 A, 28 VDC (Resistive)
TV-3 (ACTV)
DPDT
1/2 HP, 120 VAC (Motor)
10 A, 240 VAC (Inductive)
10 A, 28 VDC (Resistive)
1/2 HP, 240 VAC (Motor)
LY❏
3PDT
4PDT
CSA Certified Type (File No. LR31928)
Type
Contact form
SPDT
Coil ratings
Contact ratings
LY❏
6 to 240 VAC
6 to 120 VDC
15 A, 120 VAC (Inductive)
10 A, 240 VAC (Inductive)
15 A, 28 VDC (Resistive)
TV-5 (ACTV)
LY❏
DPDT
13 A, 28 VDC (Resistive)
12 A, 120 VAC (Inductive)
10 A, 240 VAC (Inductive)
1/3 HP, 120 VAC (Motor)
TV-3 (ACTV)
LY❏
3PDT
4PDT
10 A, 240 VAC (Inductive)
10 A, 28 VDC (Resistive)
VDE Approved Type (File No. 9903 [SPDT, DPDT & 3PDT], File No. 9947 [4PDT])
Type
Contact form
SPDT
Coil ratings
6, 12, 24, 50,
Contact ratings
LY❏-VD
10 A, 220 VAC (Resistive)
10 A, 28 VDC (Resistive)
7 A, 220 VAC (Inductive)
7 A, 28 VDC (Inductive)
7 A, 220 VAC (Resistive)
7 A, 28 VDC (Resistive)
4 A, 220 VAC (Inductive)
4 A, 28 VDC (Inductive)
110, 220 VAC
and 6, 12, 24,
48, 110 VDC
LY❏-VD
DPDT
3PDT
4PDT
LR (Lloyd's Register) Approved Type (File No. 562KOB-204523)
Type
Contact form
DPDT
4PDT
Coil ratings
6 to 240 VAC
6 to 110 VDC
Contact ratings
Contact ratings
LY❏
7.5 A, 230 VAC (Inductive)
5 A, 24 VDC (Inductive)
SEV Listed Type (File No. D7 91/82 [2- & 4-pole], D 91/204a [1- & 3-pole])
Type
Contact form
SPDT
Coil ratings
6 to 240 VAC
6 to 110 VDC
LY❏-SV
LY❏-SV
15 A, 220 VAC (Resistive)
15 A, 24 VDC (Resistive)
10 A, 220 VAC (Resistive)
10 A, 24 VDC (Resistive)
DPDT
3PDT
4PDT
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, VDE, and SEV) may be different from the performance char-
acteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
General Purpose Relay LY
731
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed 12. Warranties. (a) Exclusive Warranty. Seller's exclusive warranty is that the
part of all quotations, acknowledgments, invoices, purchase orders and other
documents, whether electronic or in writing, relating to the sale of products or
services (collectively, the "Products") by Omron Electronic Components LLC
("Seller"). Seller hereby objects to any terms or conditions proposed in
Buyer's purchase order or other documents which are inconsistent with, or in
addition to, these Terms.
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Seller (or such other period expressed
in writing by Seller). Seller disclaims all other warranties, express or implied.
(b) Limitations. SELLER MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Seller further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or oth-
erwise of any intellectual property right. (c) Buyer Remedy. Seller's sole obli-
gation hereunder shall be to replace (in the form originally shipped with Buyer
responsible for labor charges for removal or replacement thereof) the non-
complying Product or, at Seller's election, to repay or credit Buyer an amount
equal to the purchase price of the Product; provided that in no event shall
Seller be responsible for warranty, repair, indemnity or any other claims or
expenses regarding the Products unless Seller's analysis confirms that the
Products were properly handled, stored, installed and maintained and not sub-
ject to contamination, abuse, misuse or inappropriate modification. Return of
any Products by Buyer must be approved in writing by Seller before shipment.
Seller shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies, or any other materials or substances or environ-
ments. Any advice, recommendations or information given orally or in writing
are not to be construed as an amendment or addition to the above warranty.
2. Prices; Payment. All prices stated are current, subject to change without
notice by Seller. Buyer agrees to pay the price in effect at time of shipment.
Payments for Products received are due net 30 days unless otherwise stated
in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of
invoices sent to Buyer after deducting transportation charges, taxes and
duties, and will be allowed only if (i) the invoice is paid according to Seller's
payment terms and (ii) Buyer has no past due amounts owing to Seller.
4. Currencies. If the prices quoted herein are in a currency other than U.S. dol-
lars, Buyer shall make remittance to Seller at the then current exchange rate
most favorable to Seller and which is available on the due date; provided that if
remittance is not made when due, Buyer will convert the amount to U.S. dol-
lars at the then current exchange rate most favorable to Seller available during
the period between the due date and the date remittance is actually made.
5. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Products.
6. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Seller or required to be collected directly or 13. Limitation on Liability; Etc. SELLER SHALL NOT BE LIABLE FOR SPECIAL,
indirectly by Seller for the manufacture, production, sale, delivery, importation,
consumption or use of the Products sold hereunder (including customs duties
and sales, excise, use, turnover and license taxes) shall be charged to and
remitted by Buyer to Seller.
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CON-
NECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN
CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in
no event shall liability of Seller exceed the individual price of the Product on
which liability is asserted.
7. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Seller, Seller reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise 14. Indemnities. Buyer shall indemnify and hold harmless Seller, its affiliates and
comply with these Terms or any related agreement, Seller may (without liability
and in addition to other remedies) cancel any unshipped portion of Products
sold hereunder and stop any Products in transit until Buyer pays all amounts,
including amounts payable hereunder, whether or not then due, which are
owing to it by Buyer. Buyer shall in any event remain liable for all unpaid
accounts.
its employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Seller is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Seller and defend or settle
any action brought against Seller to the extent that it is based on a claim that
any Product made to Buyer specifications infringed intellectual property rights
of another party.
8. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Seller fully against all costs or expenses arising in
connection therewith.
9. Force Majeure. Seller shall not be liable for any delay or failure in delivery 15. Property; Confidentiality. The intellectual property embodied in the Products is
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
the exclusive property of Seller and its affiliates and Buyer shall not attempt to
duplicate it in any way without the written permission of Seller. Notwithstand-
ing any charges to Buyer for engineering or tooling, all engineering and tooling
shall remain the exclusive property of Seller. All information and materials sup-
plied by Seller to Buyer relating to the Products are confidential and propri-
etary, and Buyer shall limit distribution thereof to its trusted employees and
strictly prevent disclosure to any third party.
10. Shipping; Delivery. Unless otherwise expressly agreed in writing by Seller:
1. Shipments shall be by a carrier selected by Seller;
2. Such carrier shall act as the agent of Buyer and delivery to such carrier
shall constitute delivery to Buyer;
16. Miscellaneous. (a) Waiver. No failure or delay by Seller in exercising any right
and no course of dealing between Buyer and Seller shall operate as a waiver
of rights by Seller. (b) Assignment. Buyer may not assign its rights hereunder
without Seller's written consent. (c) Law. These Terms are governed by Illi-
nois law (without regard to conflict of law principles). Federal and state courts
in Illinois shall have exclusive jurisdiction for any dispute hereunder.
(d) Amendment. These Terms constitute the entire agreement between Buyer
and Seller relating to the Products, and no provision may be changed or
waived unless in writing signed by the parties. (e) Severability. If any provision
hereof is rendered ineffective or invalid, such provision shall not invalidate any
other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice.. (g) Definitions. As used
herein, "including" means "including without limitation".
3. All sales and shipments of Products shall be FOB shipping point (unless
otherwise stated in writing by Seller), at which point title to and all risk of
loss of the Products shall pass from Seller to Buyer, provided that Seller
shall retain a security interest in the Products until the full purchase price is
paid by Buyer;
4. Delivery and shipping dates are estimates only.
5. Seller will package Products as it deems proper for protection against
normal handling and extra charges apply to special conditions.
11. Claims. Any claim by Buyer against Seller for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Seller within 30 days of receipt of shipment and include the original trans-
portation bill signed by the carrier noting that the carrier received the Products
from Seller in the condition claimed.
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's
dards, codes or regulations which apply to the combination of the Product in
programming of a programmable product, or any consequence thereof.
Buyer's application or use of the Product. At Buyer's request, Seller will pro- 3. Performance Data. Performance data given in this publication is provided as a
vide applicable third party certification documents identifying ratings and limita-
tions of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in combi-
nation with the end product, machine, system, or other application or use.
guide for the user in determining suitability and does not constitute a warranty
It may represent the result of Seller's test conditions, and the users must corre
late it to actual application requirements. Actual performance is subject to
Seller's Warranty and Limitations of Liability.
Buyer shall be solely responsible for determining appropriateness of the partic- 4. Change in Specifications. Product specifications and accessories may be
ular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases but the following is a non-
exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii)Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to
changed at any time based on improvements and other reasons. It is our prac
tice to change part numbers when published ratings or features are changed
or when significant construction changes are made. However, some specifica
tions of the Product may be changed without any notice. When in doubt, spe
cial part numbers may be assigned to fix or establish key specifications for you
application. Please consult with your Seller representative at any time to con
firm actual specifications of purchased Product.
5. Errors and Omissions. The information in this publication has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
6. RoHS Compliance. Where indicated, our products currently comply, to the bes
of our knowledge as of the date of this publication, with the requirements of the
European Union's Directive on the Restriction of certain Hazardous Sub
stances ("RoHS"), although the requirements of RoHS do not take effect unti
July 2006. These requirements may be subject to change. Please consult ou
website for current information.
separate industry or government regulations.
(iii)Use in consumer products or any use in significant quantities.
(iv)Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Canada - http://www.omron.ca
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
416-286-6465
847-882-2288
Cat. No. JB301-E3-01
3/05
Specifications subject to change without notice
Printed in USA
LY4F-AC240 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
LY4F-AC6 | OMRON | POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 1200mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT | 获取价格 | |
LY4F-DC110 | OMRON | Power/Signal Relay, 4PDT, Momentary, 0.016A (Coil), 110VDC (Coil), 1500mW (Coil), 10A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Panel Mount, | 获取价格 | |
LY4F-DC12 | OMRON | POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 0.12A (COIL), 12VDC (COIL), 1500mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT | 获取价格 | |
LY4F-DC24 | OMRON | POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 0.069A (COIL), 24VDC (COIL), 1500mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT | 获取价格 | |
LY4F-DC48 | OMRON | POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 0.03A (COIL), 48VDC (COIL), 1500mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT | 获取价格 | |
LY4F-DC6 | OMRON | POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 0.24A (COIL), 6VDC (COIL), 1500mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT | 获取价格 | |
LY4FAC100/110 | OMRON | POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 2500mW (COIL), 10A (CONTACT), 125VDC (CONTACT), PANEL MOUNT | 获取价格 | |
LY4FAC200/220 | OMRON | POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 2500mW (COIL), 10A (CONTACT), 125VDC (CONTACT), PANEL MOUNT | 获取价格 | |
LY4FAC50 | OMRON | Power/Signal Relay, 4PDT, Momentary, 1200mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount | 获取价格 | |
LY4FAC6 | OMRON | Power/Signal Relay, 4PDT, Momentary, 1200mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount | 获取价格 |
LY4F-AC240 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6