M7F-4N1G [OMRON]

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.;
M7F-4N1G
型号: M7F-4N1G
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.

文件: 总16页 (文件大小:2120K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Digital Display  
M7F  
CSM_M7F_DS_E_10_1  
A Series of Three- to Five-digit Digital  
Display Units with a Character Height of  
14 mm. Models available with either red or  
green displays.  
• Red or green displays with a character height of 14 mm are  
available for a variety of applications and locations.  
• Miniature design with a 50-mm depth.  
• Incorporating a connector, thus saving wiring effort.  
• Connecting to OMRON's PLCs via dedicated PLC cables (sold  
separately).  
• Units and minus symbols are displayed (three- and four-digit  
model only).  
• Incorporating a zero suppression function.  
• The power supply can freely change between 12 and 24 VDC.  
• CE Marking. UL certification approval.  
Model Number Structure  
Model Number Legend  
M7F-@@@@@  
1
2
3
4
5
1. No. of Numeral Display Digits  
(No. of 7-segment LED Indicators)  
4. Display Color  
Code  
Color  
Code  
No. of digits  
3 digits  
R
G
Red  
3
4
5
Green  
4 digits  
5 digits  
5. Display Contents  
Code  
Display Contents  
Numerals and minus symbol  
Numerals and units  
2. Input Method  
F
T
Code  
Input Method  
P
N
D
Static positive logic  
Static negative logic  
Dynamic  
None Numerals only  
Note: 1. The input type for the five-digit model is dynamic only.  
2. Dynamic input is available with the four-digit model as well as the five-  
digit model.  
3. LED  
Code  
1
3. The minus symbol and units are available with three and four-digit  
models only.  
Character Height  
4. Three-digit models with numerals only are not available.  
14 mm  
Construction and Nomenclature  
Nomenclature  
s
I/O Connector  
(OMRON's XG4A-2031)  
Use with OMRON's XG4M-2030-T, XG5M-2032-N, XG5M-2035-N or  
equivalent socket.  
Connected to OMRON's PLCs with ease by using OMRON's  
G79-@C, G79-Y@C, or G79-O@C-@ Cable. Refer to page 3 for details.  
Power Supply Terminal  
Connect 12 to 24 VDC.  
DIP Switch  
Seven-segment LED  
Used for decimal point and negative value settings.  
Refer to page 6 for details.  
Character height: 14 mm  
Color:  
Character:  
Red or green  
Numerals only  
Numerals and minus symbol (for three- and four-digit models only)  
Numerals and units (for three- and four-digit models only)  
1
M7F  
Ordering Information  
List of Models  
Accessories  
No. of  
Appearance Display  
Input  
method  
Logic  
Display contents  
Model  
(Order Separately)  
digits  
color  
3
Red  
Static  
Static  
Static  
Positive  
Numerals and minus symbol M7F-3P1RF  
Numerals and units M7F-3P1RT*  
Negative Numerals and minus symbol M7F-3N1RF  
Numerals and units M7F-3N1RT*  
Numerals and minus symbol M7F-3P1GF  
Numerals and units M7F-3P1GT*  
Negative Numerals and minus symbol M7F-3N1GF  
Unit Plate  
Choose the required unit plate from the  
following tables in order to attach it to the  
Unit Display Unit.  
Unit Plates are replaceable.  
Ten Unit Plates are sold as a set. (The  
Green  
Red  
Positive  
number per set is the same for all models.)  
The characters are white.  
Numerals and units  
Numerals only  
M7F-3N1GT*  
M7F-4P1R  
4
Positive  
Numerals and minus symbol M7F-4P1RF  
Display Single item (sheet only):  
Numerals and units  
Negative Numerals only  
M7F-4P1RT*  
M7F-4N1R  
contents  
1 Set of 10 sheets  
M7F-1  
Blank  
display  
Numerals and minus symbol M7F-4N1RF  
Numerals and units  
Numerals only  
M7F-4N1RT*  
M7F-4D1R  
M7F-RPM-1  
M7F-PER-1  
M7F-KG-1  
M7F-MM-1  
M7F-M-1  
Dynamic  
Static  
Positive  
Positive  
rpm  
Numerals and minus symbol M7F-4D1RF  
Numerals and units  
Numerals only  
M7F-4D1RT*  
M7F-4P1G  
%
kg  
Green  
Numerals and minus symbol M7F-4P1GF  
Numerals and units  
Negative Numerals only  
M7F-4P1GT*  
M7F-4N1G  
mm  
m
Numerals and minus symbol M7F-4N1GF  
Numerals and units  
Numerals only  
M7F-4N1GT*  
M7F-4D1G  
Dynamic  
Positive  
Numerals and minus symbol M7F-4D1GF  
M7F-DOC-1  
M7F-PCS-1  
Numerals and units  
Numerals only  
M7F-4D1GT*  
M7F-5D1R  
M7F-5D1G  
°C  
5
Red  
Dynamic  
Dynamic  
Positive  
Positive  
Green  
Numerals only  
pcs  
Connectable PLCs  
Compatibility with OMRON PLCs (Examples)  
M7F model  
PLC's output method  
Static output Dynamic  
output  
PLC Output Unit  
M7F model  
CS1W-OD211  
M7F-@N@@  
C200H-OD215/218/219  
C500-OD213  
Input Logic input PNP output NPN output  
Static Positive  
Negative  
×
×
CQM1-OD213  
×
×
×
CS1W-OD212  
C500-OD212  
M7F-@P@@  
M7F-@D@@  
Dynamic  
×
C200H-OD215  
: Connectable (See note 1.)  
×: Not connectable  
Note: 1. External resistance not required  
2. Refer to External Connections on page 9 for details.  
2
M7F  
Cables  
Use the following cables and connectors to connect the M7F to the PLC or other devices.  
Model name  
Application  
Appearance  
Ordering Information  
G79-@C  
Connects the M7F  
and a single device.  
Applicable PLC  
Output Units:  
Cable with  
Connectors  
(1 to 1)  
C500-OD415CN,  
C200H-OD215, and  
C200H-MD215  
(Output Units  
incorporating a 24-pin  
connector each)  
PLC  
M7F  
L
OMRON's C500-CE243  
OMRON's  
(Fujitsu's FCN-36@@040  
Series)  
XG4M-2030-T  
Connection  
L Dimensions  
Model  
G79-100C  
G79-150C  
G79-200C  
G79-300C  
G79-500C  
1,000 mm  
1,500 mm  
2,000 mm  
3,000 mm  
5,000 mm  
On the PLC  
Connector pin No.  
M7F Connector  
pin No.  
(Line A Line B)  
1
2
3
4
5
6
7
8
9
11  
12  
13  
14  
15  
16  
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Polarity  
guide  
17  
18  
19  
10 20  
10 10  
11 11  
12 12  
Triangular mark  
G79 cable  
with connector (1 to 1)  
Note: The connector pin numbers are  
shown from the crimped sides of  
the connectors.  
G79-O@C-@ Connects the M7F  
Cable with  
Connectors  
(1 to 2)  
and two devices.  
Suitable Output Units:  
C500-OD213,  
C200H-OD218,  
C200H-OD219,  
CQM1-OD213,  
CS1W-MD261,  
CJ1W-OD231, and  
CJ1W-OD261  
(Output Units  
incorporating a 40-pin  
connector each)  
L Dimensions  
For output  
Model  
A
B
1,000 mm 750 mm G79-O100C-75  
1,500 mm 1,250 mm G79-O150C-125  
2,000 mm 1,750 mm G79-O200C-175  
3,000 mm 2,750 mm G79-O300C-275  
5,000 mm 4,750 mm G79-O500C-475  
OMRON's C500-CE403  
(Fujitsu's FCN-36@@040  
a
Series)  
M7F  
PLC  
OMRON's  
XG4M-2030-T  
b
Straight length (with no bend)  
G79-Y@C  
Cable with  
Crimp-style  
Terminals  
Ideal for the  
connection of the M7F  
to devices  
incorporating screw  
terminals.  
Suitable Output Units:  
CS1W-OD211,  
CS1W-OD212,  
C200H-OD212, and  
C500-OD412  
L Dimensions  
1,000 mm  
1,500 mm  
2,000 mm  
3,000 mm  
5,000 mm  
Model  
G79-Y100C  
G79-Y150C  
G79-Y200C  
G79-Y300C  
G79-Y500C  
Device  
side  
M7F  
L
300  
OMRON's  
XG4M-2030-T  
3
M7F  
Specifications  
Applicable EN Standards  
Characteristics  
Standards  
Insulation  
100 Mmin. (at 500 VDC) between each terminal and  
resistance mounting panel  
EN61326  
EN60529  
UL61010-1  
Dielectric  
strength  
1,000 VAC, 50/60 Hz for 1 min between each terminal  
and mounting panel  
Noise  
immunity  
(See note.)  
Power terminal: 500 V (normal mode)  
1,500 V (common mode)  
Ratings  
Rated power supply  
I/O cable:  
800 V (when the specified cable is  
used)  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude  
12 to 24 VDC  
Vibration  
Allowable voltage fluctuation range 90% to 110% of rated voltage  
resistance 10 sweeps of 5 min each in X, Y, and Z directions  
Current consumption  
200 mA max. (at 12 VDC)  
100 mA max. (at 24 VDC)  
Malfunction: 300 m/s2  
3 times each in 6 directions on X, Y, and Z axes  
Shock  
resistance  
Input level  
Static  
input  
Positive  
Negative  
High: 9.6 V to power supply voltage  
Low: 0 to 3 V  
Degree of  
protection  
IEC IP40 (front panel only)  
High: 4 V to power supply voltage  
Low: 0 to 1.5 V  
Note: Impulse conditions:  
Rise time: 1 ns +10% max.  
Pulse width: 100 ns, 1 µs  
Frequency: 100 Hz  
Dynamic Positive  
input (See note.)  
High: 4 V to power supply voltage  
Low: 0 to 1.5 V  
Ambient temperature  
Operating: 10 to 55°C (with no icing  
or condensation)  
Polarity:  
Cable:  
Positive or negative  
OMRON's G79-100C  
Storage: 25 to 65°C (with no icing or  
condensation)  
Ambient humidity  
Operating: 35% to 85% (with no icing  
or condensation)  
Note: Use an NPN open collector for the output of the connection  
device. The data signal, however, is positive logic and the  
strobe signal is negative logic.  
4
M7F  
Operation  
Input Codes  
Numeric Display  
Positive Logic Static Input (M7F-@P@@@)  
Input signal  
Display condition  
103 digit  
102 digit  
101 digit  
100 digit  
Terminal no.  
R
Q
P
O
N
M
L
K
H
G
F
E
D
C
B
A
A1 103 102 101 100  
digit digit digit digit  
Terminal  
symbol  
D4  
C4  
B4  
A4  
D3  
C3  
B3  
A3  
D2  
C2  
B2  
A2  
D1  
C1  
B1  
Input signals  
L
L
L
L
L
L
L
H
L
L
L
L
L
L
L
L
H
L
L
L
L
L
L
L
L
H
L
L
L
L
L
L
L
L
H
L
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
L
L
H
H
L
L
L
H
H
L
L
L
H
H
L
L
L
H
H
L
L
L
H
L
L
L
H
L
L
L
H
L
L
L
H
L
L
H
H
H
H
L
L
H
H
H
H
L
L
H
H
H
H
L
L
H
H
H
H
L
L
L
H
L
L
L
H
L
L
L
H
L
L
L
H
L
L
H
H
L
L
H
H
L
L
H
H
L
L
H
H
L
L
H
L
L
H
L
L
H
L
L
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
L
H
L
L
L
H
L
L
L
H
L
L
L
H
L
L
H
H
L
L
H
H
L
L
H
H
L
L
H
H
L
L
H
L
L
H
L
L
H
L
L
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
H
L
L
H
L
L
H
L
L
H
L
H
H
H
H
H
H
H
H
H
H
H
H
Negative Logic Static Input (M7F-@N@@@)  
Input signal  
Display condition  
103 digit  
102 digit  
101 digit  
100 digit  
Terminal no.  
R
Q
P
O
N
M
L
K
H
G
F
E
D
C
B
A
A1 103 102 101 100  
digit digit digit digit  
Terminal  
symbol  
D4  
C4  
B4  
A4  
D3  
C3  
B3  
A3  
D2  
C2  
B2  
A2  
D1  
C1  
B1  
Input signals  
H
H
H
H
H
H
H
H
L
H
H
H
H
L
H
H
L
H
L
H
H
H
H
H
H
H
H
L
H
H
H
H
L
H
H
L
H
L
H
H
H
H
H
H
H
H
L
H
H
H
H
L
H
H
L
H
L
H
H
H
H
H
H
H
H
L
H
H
H
H
L
H
H
L
H
L
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
0
1
2
3
4
5
6
7
8
9
a
b
c
d
e
f
H
L
H
L
H
L
H
L
L
L
L
L
H
H
L
H
L
H
H
L
H
L
H
H
L
H
L
H
H
L
H
L
L
L
L
L
L
H
L
L
H
L
L
H
L
L
H
L
L
L
L
L
L
L
L
L
H
H
H
H
L
H
H
L
H
L
H
H
H
H
L
H
H
L
H
L
H
H
H
H
L
H
H
L
H
L
H
H
H
H
L
H
H
L
H
L
L
L
L
L
L
H
L
L
H
L
L
H
L
L
H
L
L
L
L
L
L
L
L
L
L
H
H
L
H
L
L
H
H
L
H
L
L
H
H
L
H
L
L
H
H
L
H
L
L
L
L
L
L
L
L
L
L
L
H
L
L
L
H
L
L
L
H
L
L
L
H
L
L
L
L
L
L
L
L
L
L
L
L
L
5
M7F  
Dynamic Input (M7F-@D@@@)  
Input signal  
Display condition  
Terminal no.  
D
C
B
A
K
L
M
N
O
S4 104 103 102 101 100  
digit digit digit digit digit  
Terminal  
symbol  
D
C
B
A
S0  
S1  
S2  
S3  
Input signals  
L
L
L
L
L
L
L
H
L
L
H
H
H
H
L
H
L
H
H
L
H
H
H
L
H
H
H
H
L
*
*
*
*
*
*
*
1
*
0
*
L
L
H
H
L
H
H
H
H
L
*
*
2
*
*
L
L
H
L
H
H
H
H
L
*
3
*
*
*
L
H
H
H
H
L
H
H
H
H
L
4
*
*
*
*
L
L
H
L
H
H
H
H
L
*
*
*
5
*
L
H
H
L
H
H
H
H
L
*
*
*
6
*
L
H
L
H
H
H
H
L
*
*
7
*
*
H
H
H
H
H
H
H
H
H
H
H
H
L
*
8
*
*
*
L
L
H
L
H
H
H
H
L
9
*
*
*
*
L
H
H
L
H
H
H
H
L
*
*
*
a
*
L
H
L
H
H
H
H
L
*
*
*
b
*
* The data of S0 to S4 when S0 to S4  
are high before S0 to S4 become  
low will be held and displayed. Refer  
to Operation Timing (Input Signal  
Timing) on page 12 and Operation  
Chart on page 12 for details.  
H
H
H
H
H
H
H
H
*
*
c
*
*
L
H
L
H
H
H
*
d
*
*
*
H
H
H
H
e
*
*
*
*
H
H
*
*
*
f
Unit Display  
Zero Suppression Function  
The displays are lit when voltage is supplied to the power supply  
terminals (positive and negative terminals).  
The Unit has a function for blanking (i.e., turning OFF the display) to  
not display 0 when the leftmost digits are zero. When DP (decimal  
point) has been displayed using the DIP switch, the digits to the left  
of the decimal point display digit will be blank as shown in the  
following figure.  
Minus Symbol and Decimal Point  
The DIP switch is used for minus symbol and decimal point settings  
as shown in the following table.  
Fourth  
digit  
Third Second First  
digit digit digit  
Display  
contents  
Model  
DIP switch function  
No decimal point is designated.  
The second, third, and fourth digits  
are blank.  
Threedigits M7F-3@@@F  
Numerals  
and minus  
symbol  
There is a decimal point between  
the first and second digits.  
The third and fourth digits are  
blank.  
Threedigits M7F-3@@@T  
Numerals  
and unit  
DP  
There is a decimal point between  
the third and second digits.  
The fourth digit is blank.  
Four digits M7F-4@@@  
DP  
Numerals  
only  
There is a decimal point between  
the fourth and third digits.  
All digits are displayed.  
DP  
Four digits M7F-4@@@F  
Numerals  
and minus  
symbol  
Note: The zero suppression function is normally operating.  
Four digits M7F-4@@@T  
Numerals  
and unit  
Five digits M7F-5@@@  
Numerals  
only  
Note: 1. The minus symbol and decimal point are always lit when the  
corresponding pins of the DIP switch are set to ON.  
2. “NC” means “not connected”.  
6
M7F  
Terminal Arrangement/Functions  
Terminal Arrangement  
XG4A Connector  
XG4A Connector  
Dynamic Input Model  
Static Input Model  
Signal input  
Power supply  
Power supply  
Signal input  
Triangular  
Triangular  
mark on  
socket *  
mark on  
socket *  
Power supply (+)  
Polarity guide  
Terminal name  
DIP Switch  
Power supply ()  
Terminal guide  
Case  
mark  
Case  
mark  
Signal input  
Power supply  
Signal input  
Power supply  
Note: 1. Circled numbers are for the user's convenience. When preparing a socket, pay attention  
when wiring the terminals to the direction of the polarity guide.  
2. The triangular mark ( ) on the M7F case indicates the start of the M7F terminal numbers. It  
does not line up with the triangular mark ( ) on the connector. Incorrect wiring may cause a  
short-circuit in the sequence output section, which could damage it.  
* This is the location of the triangular mark on the XG4M-2030 Socket that is attached to the  
Cable.  
Terminal Functions  
Input method  
Terminal  
symbol  
Name  
Function  
First digit (100)  
data input  
A1 (20)  
B1 (21)  
C1 (22)  
D1 (23)  
Static input  
A1  
B1  
C1  
D1  
The numeral or symbol corresponding to the binary code signal will be  
displayed as the first digit (100).  
Second digit (101) A2 (20)  
data input  
A2  
B2  
C2  
D2  
The numeral or symbol corresponding to the binary code signal will be  
displayed as the second digit (101).  
B2 (21)  
C2 (22)  
D2 (23)  
Third digit (102)  
data input  
A3 (20)  
B3 (21)  
C3 (22)  
D3 (23)  
A3  
B3  
C3  
D3  
The numeral or symbol corresponding to the binary code signal will be  
displayed as the third digit (102).  
Fourth digit (103) A4 (20)  
data input  
A4  
B4  
C4  
D4  
The numeral or symbol corresponding to the binary code signal will be  
displayed as the fourth digit (103).  
B4 (21)  
C4 (22)  
D4 (23)  
+V  
Power supply  
Power supply  
Data input  
Power supply and output terminal  
0 V  
Power supply 0-V output terminal (GND)  
A (20)  
B (21)  
C (22)  
D (23)  
Dynamic input  
A
B
C
D
Displays the numeral or symbol corresponding to the binary code signal.  
S0 (100)  
S1 (101)  
S2 (102)  
S3 (103)  
S4 (104)  
S0  
S1  
S2  
S3  
S4  
Control input  
Designates the digit to be displayed. Each digit will maintain the previous  
value when this signal is input.  
+V  
Power supply  
Power supply  
Power supply and output terminal  
0 V  
Power supply 0-V output terminal (GND)  
DIP Switch Function  
The DIP switch is used for symbol and decimal point settings. Refer to Terminal Arrangement, above, for details.  
7
M7F  
Block Diagram  
Note: Circled numbers are the connector pin numbers.  
Static Input Method  
Dynamic Input Method  
External  
power  
supply input  
Switching  
regulator  
External  
Switching  
power  
Power supply  
regulator  
supply input  
output into  
the PLC  
Power supply  
output into  
the PLC  
Signal  
input  
A1 to D1  
A2 to D2  
A3 to D3  
A4 to D4  
to  
to  
to  
to  
Signal  
input  
LED display  
elements  
Strobe  
Signal Input  
LED display elements  
Signal Positive Logic Input Method  
Signal Data signal input  
Input  
Input  
Circuit  
Signal input  
Circuit  
Short-circuit (ON) impedance  
: 1 kǡ max.  
ON voltage  
: 9.6 V to power  
supply voltage  
: 3 VDC max.  
Short-circuit (ON) residual voltage  
: 3 VDC max.  
Signal input  
OFF voltage  
Current flow for 0-ǡ short-circuit  
: Approx. 0.2 mA  
Input impedance : Approx. 70 kǡ  
Open (OFF) impedance  
: 100 kǡ min.  
Negative Logic Input Method  
Strobe signal input  
Short-circuit (ON) impedance  
: 1 kǡ max.  
Short-circuit (ON) impedance  
: 1 kǡ max.  
Short-circuit (ON) residual voltage  
Short-circuit (ON) residual voltage  
: 3 VDC max.  
: 3 VDC max.  
Signal input  
Signal input  
Current flow for 0-ǡ short-circuit  
: Approx. 0.2 mA  
Current flow for 0-ǡ short-circuit  
: Approx. 0.2 mA  
Open (OFF) impedance  
Open (OFF) impedance  
: 100 kǡ min.  
: 100 kǡ min.  
8
M7F  
External Connections  
Refer to Block Diagram on page 8 and Terminal Arrangement on  
page 7 for external connections for the M7F according to the signal  
input method.  
PLC Connections  
Refer to your PLC operation manual before connecting the PLC.  
The M7F connects to the PLC without using any external resistor.  
It is necessary to select the correct input method of the M7F  
according to the output method of the PLC Output Unit. Refer to  
Connectable PLCs on page 2 for details on the selection of the  
correct input method.  
A PLC Dynamic Output Unit can be used to save wiring. Use a  
dynamic input model (M7F-@D@@@).  
With PLC Static Output Unit  
1. M7F-@P@@@ Static Positive Logic Input Model  
Connected to C500-OD212 Output Unit  
PLC  
Termi-  
nal No.  
Terminal  
name  
Circuit Configuration  
PLC  
A to D  
0 V  
0 V  
PLC Output  
Unit  
Power  
supply  
input  
DC power  
supply (+)  
12 to 24 VDC  
(0 V)  
Power  
supply  
input  
Note: 1. Use the M7F positive logic input model if the PLC Output Unit has PNP output.  
2. The PLC connects to the M7F with ease via the enclosed G79-Y@C Cable (with  
connectors, sold separately).  
9
M7F  
2. M7F-@N@@@ Static Negative Logic Input Model  
1. Connected to C500-OD213 Output Unit  
PLC  
Termi-  
nal No.  
Terminal  
name  
Circuit Configuration  
PLC  
A to D  
PLC Output  
Unit  
Power  
supply  
input  
DC power  
supply (+)  
12 to 24 VDC  
(0 V)  
Power  
supply  
input  
Note: The PLC connects to the M7F with ease via the G79-O@C-@ Cable (with connectors, sold separately).  
(The above example indicates 1 to 1 connection.)  
2. Connected to C200H-OD215 Output Unit  
PLC  
Termi-  
nal No.  
Terminal  
name  
Circuit Configuration  
PLC  
A to D  
Power  
supply  
input  
DC power  
supply (+)  
12 to 24 VDC  
(0 V)  
Power  
supply  
input  
PLC Output  
Unit  
Fuse  
Note: 1. If the C200H-OD215 is used as a Static Output Unit, the switches on the rear panel of the PLC must be set as described in  
the following table.  
SW1 (static output mode)  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
SW2  
SW3  
SW4  
SW5 (negative logic output)  
SW6  
Refer to your PLC operation manual for details.  
2. A G79-@C Connecting Cable (with connectors, sold separately) can be used to easily connect the PLC to the M7F.  
10  
M7F  
With PLC Dynamic Output Unit  
M7F-@D@@@ Dynamic Input Model  
Connected to C200H-OD215 Output Unit  
PLC  
Termi-  
nal No.  
Terminal  
name  
Circuit Configuration  
PLC  
A to D  
S0 to S4  
Power  
supply  
input  
DC power  
supply (+)  
12 to 24 VDC  
(0 V)  
Power  
supply  
input  
PLC Output  
Unit  
Fuse  
Note: 1. If the C200H-OD215 is used as a Dynamic Output Unit, the switches on the rear panel of the PLC must be set as described  
in the following table.  
SW1 (dynamic output mode)  
ON  
SW2  
OFF  
OFF  
OFF  
ON  
SW3  
SW4  
SW5 (positive logic output)  
SW6  
Refer to your PLC operation manual for details.  
OFF  
2. A G79-@C Connecting Cable (with connectors, sold separately) can be used to easily connect the PLC to the M7F.  
3. An eight-bit data signal is allocated to each strobe signal of the C200H-OD215 Dynamic Output Unit. On the other hand, each  
strobe signal is input only to the rightmost four bits of the M7F. Thus the following program must run.  
1. Status before PLC Program Runs (Data Storage Status)  
2. Example of PLC Program Operation  
(Refer to your PLC operation manual for details.)  
Relay no.  
Data no.  
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Transfers the first digit's data of word 005 to the  
first digit of word 100.  
Word 005  
4
3
2
1
5
no.  
006  
Transfers the second digit's data of word 005 to  
the third digit of word 100.  
007  
008  
Transfers the third digit's data of word 005 to  
the first digit of word 101.  
Note: Word numbers and data are examples.  
Transfers the fourth digit's data of word 005 to  
the third digit of word 101.  
M7F 's display  
Transfers the first digit data of word 006 to the  
first digit of word 102.  
3. Status after PLC Program Has Run (Data Storage Status)  
Relay no.  
Data no.  
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Word 100  
2
4
1
3
5
no.  
101  
102  
103  
Note: Word numbers and data are examples.  
M7F 's display  
11  
M7F  
Operation  
Operation Timing (Input Signal Timing)  
Dynamic Input Method (M7F-@D@@@)  
Data input  
signals A to D  
Pulse duration (tw) 1.5 ms  
ts  
th  
Hold time (th)  
Setup time (ts)  
0.75 ms  
2.25 ms  
H
L
Strobe input  
(S0 to S4)  
Data latch  
Data read  
tw  
Data latch  
Operation Chart  
Dynamic Input Method (M7F-@D@@@)  
The following example shows the relationship between each input terminal and the display condition. (Example: 5-digit)  
Data contents  
5
3
1
8
9
Data input  
signals  
(A to D)  
Data read  
1st digit  
(S0)  
H
L
Data input signals  
Data latch  
Data latch  
Data read  
2nd digit  
(S1)  
H
L
Data latch  
Data latch  
Data read  
Data read  
3rd digit  
(S2)  
H
L
Data latch  
Data latch  
4th digit  
(S3)  
H
L
Strobe input signals  
Data latch  
Data latch  
Data read  
5th digit  
(S4)  
H
L
Data latch  
A numeric value is  
displayed one digit at a  
time via data signals A  
to D.  
1st-digit display change  
2nd-digit display change  
3rd-digit display change  
4th-digit display change  
5th-digit display change  
Display  
condition  
12  
M7F  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
67.5  
50  
M7F-@@1@@  
M7F-4@1@F  
4
(13.5)  
LED  
10°  
30.4  
14.2  
Panel Cutout  
M7F-4@1@T  
M7F-5D1@  
(Single Mounting)  
+0.6  
67  
0.4  
The M7F-4@1@ is  
illustrated.  
7.8  
31  
M7F-3@1@F  
(Side-by-side Mounting)  
72  
68  
66  
+0.6  
(72n5)  
0.4  
+0.6  
31  
0.4  
M7F-3@1@T  
36 29 14.22  
7 min.  
M7F-4@1@  
Panel thickness: 1 to 6 mm  
n: Number of Units mounted  
66.5  
13  
M7F  
Safety Precautions  
Precaution for Correct Use  
!CAUTION  
Tighten the screws on the terminal block securely using  
the recommended tightening torque of 0.29 to 0.49 N·m.  
Loose screws may occasionally cause fire, resulting in  
minor or moderate injury, or damage to the equipment.  
Wiring  
Do not tighten the power supply terminals with excessive force  
when wiring. Doing so may damage the terminals. Tighten each of  
them to a torque of 0.29 to 0.49 N·m.  
Do not impose excessive force on the rear panel when tightening  
Precautions for Safe Use  
the terminals of the M7F or connecting a connector to the M7F.  
Do not use or store the product in the following locations.  
When tightening the terminals of the M7F or connecting a  
connector to the M7F, hold the displays by hand, otherwise the  
displays may protrude from the case.  
Locations subject to direct radiant heat from heating equipment  
Locations where the product may come into contact with water,  
oil, or salt water  
Environment  
When using the M7F in places with dust, metal powder, or sprayed  
oil, be sure to take appropriate measures so that no dust, metal  
powder, or sprayed oil will penetrate the interior of the Display Units.  
Locations subject to direct sunlight  
Locations where dust or corrosive gases (in particular, sulfuric  
or ammonia gas) are present  
Locations subject to extreme temperature changes  
Locations where icing or condensation may occur  
Locations subject to excessive shocks or vibration  
Mounting  
When panel-mounting, make sure that the side of the case marked  
“TOP” is upward.  
Locations subject to temperatures or humidity outside the  
specified range  
When panel-mounting, do not press the central part of the displays,  
otherwise the displays may be damaged. Press the flange part.  
Locations outdoors or exposed to wind or rain  
Locations subject to static electricity or noise  
Connections  
If power will be supplied to the M7F from the PLC's I/O service  
power supply, make sure that the current consumption of the M7F  
does not exceed the rated capacity of the service power supply.  
It is recommended to supply power to the M7F from a dedicated  
DC power supply in order to protect the PLC from being damaged.  
When using a controller other than the PLC or another company's  
PLC, be sure to check the terminal arrangement of the connector of  
the controller or the PLC. The terminal arrangement of OMRON's  
cables incorporating connectors corresponds to that of the PLC.  
Do not use the product in locations subject to temperatures outside  
the specified ranges or in locations subject to condensation. If the  
product is installed in a panel, be sure that the temperature around  
the product (not the temperature around the panel) does not go  
outside the specified range. The life of components is dependent  
on the temperature. The life of components shortens when the  
temperature rises, and it lengthens when the temperature falls. The  
life of components can be lengthened by lowering the temperature  
inside the product.  
Do not install the product near devices generating strong high  
frequency waves or surges. When using a noise filter, check the  
voltage and current and install it as close to the product as  
possible.  
Do not touch terminals or perform wiring while power is supplied to  
the product. Doing so may result in injury or malfunction.  
Removing Color Plate  
There is a gap (with a width of approximately 1 mm) between the  
case and color plate on the left and right sides. To remove the color  
plate, insert a flat-blade screwdriver into either one of the gaps and  
move the color plate upwards.  
Do not touch the terminals while power is being supplied. Doing so  
may result in product failure or malfunction.  
Case  
Color plate  
When tightening the terminals or connecting connectors, support  
the product with one hand to prevent it from being pushed out of the  
front of the panel.  
Wire to the correct terminal number. Incorrect wiring may result in  
damage to or burning of components.  
Be sure power supplies and power lines for control power supply  
and inputs have appropriate specifications. Not using power  
supplies and power lines with appropriate specifications may result  
in malfunction, burning, or electric shock.  
Do not attempt to disassemble, repair, or modify the product. Doing  
so may occasionally result in minor or moderate injury.  
Replacing Unit Plate  
Do not allow pieces of metal, wire clippings, or fine metallic  
shavings or filings to enter the product. Doing so may occasionally  
result in fire or product failure.  
For DC input, use an SELV power supply with overcurrent  
protection. Specifically, use an SELV power supply with double or  
reinforced insulation between input and output, and an output  
voltage of 30 Vrms with 42.2 V peak or 60 VDC maximum.  
Recommended power supply: S8VS-06024@ (OMRON product)  
Remove the unit plate with a pair of tweezers.  
Before pasting a unit plate to the plate holder, remove the ground  
paper from the unit plate. Paste the unit plate to the plate holder so  
that the symbol mark or character(s) of the face plate will be on the  
bottom side (i.e., the decimal-point side) of the M7F.  
l
ay pane  
TOP displ  
Unit plate  
Plate holder  
14  
M7F  
Attaching Color Plate  
Insert the projecting parts of the color plate into the square holes of  
the case to attach the color plate to the case.  
are  
re  
Color plate projecting part (There  
projecting parts.)  
r plate  
four colo  
Square hole (There are four squa  
holes.)  
DIP Switch Settings  
The DIP switch can be set with the tip of a ball-point pen or small  
screwdriver. Do not use anything that has a sharp edge (e.g.,  
tweezers) to set the DIP switch.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
15  
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2013.7  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2013 All Right Reserved.  

相关型号:

M7F-4N1GF

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4N1GT

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4N1R

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4N1RF

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4N1RT

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4P1G

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4P1GF

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4P1GT

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4P1R

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4P1RF

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-4P1RT

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON

M7F-5D1G

A Series of Three- to Five-digit Digital Display Units with a Character Height of 14 mm. Models available with either red or green displays.
OMRON