描述:Power/Signal Relay, 3PDT, Momentary, 0.224A (Coil), 6VDC (Coil), 1400mW (Coil), 10A (Contact), 250VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
MKS3PN-D-5DC6 概述
Power/Signal Relay, 3PDT, Momentary, 0.224A (Coil), 6VDC (Coil), 1400mW (Coil), 10A (Contact), 250VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
MKS3PN-D-5DC6 数据手册
通过下载MKS3PN-D-5DC6数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载General Purpose Relays
MKS
Exceptionally Reliable General Purpose
Relay now available with Lockable Test
Button
• IEC Rating of 7A 250 V AC 50/60 Hz,
General use 100,000 cycles.
• Mechanical indicator standard for all models.
• Optional features include lockable test button, LED
indicator, diode surge suppression, varistor, reverse
polarity, and alternate wiring styles.
• UL (RU/CRU), CE and TUV approved.
• RoHS Compliant.
Features
Two-way Action Test Button (Models with Lockable Test Button)
Relay in
Normal Operation
For Momentary
Operation
For Lock
Operation
Yellow
button
Slide the latching lever
to the first position,
then press the yellow
button with an insulated
tool to operate the
contact.
Slide the latching lever
to the second position.
(The contact is now in
the locked position.)
Note: The latching lever is Red for AC Coil versions and Blue for DC Coil versions.
Model Number Structure
■ Model Number Legend
MKS@@@@@-@-@
1 2 3 4 5
6
7
1. Contact Form
5. Coil Polarity
Blank: Standard
2:
3:
DPDT
3PDT
1:
Reverse polarity (DC coil only)
2. Terminals
P: Plug-in
6. Surge Absorption
Blank:Standard
3. Mechanical Indicator/Test Button
D:
V:
Surge absorber diode (DC coil only)
Surge absorber varistor (AC coil only)
Blank:Mechanical indicator
I:
Mechanical indicator and lockable test button
7. Internal Connections DPDT
4. LED Indicator
Blank: Standard
Blank: Standard
2 or 5: Non-standard connections.(Refer to “Terminal Arrange-
ment/Internal Connection (Bottom View)”.)
N:
LED indicator
8. Rated Voltage
(Refer to “Coil Ratings”.)
General Purpose Relays MKS
299
Ordering Information
■ List of Models
Type
Terminals Contact form
Internal connections
(See note 3.)
With mechanical indicator With mechanical indicator Coil ratings
and lockable test button
Basic
Models
Plug-in
DPDT
3PDT
Standard
MKS2P
MKS2PI
AC/DC
AC/DC
DC
Non Standard
Standard
MKS2P-2
MKS2PI-2
MKS3P
MKS3PI
Non Standard
MKS3P-2
MKS3PI-2
MKS3P-5
MKS3PI-5
Models with
LED Indicator
(See note 2.)
DPDT
3PDT
Standard
MKS2PN(1)
MKS2PN(1)-2
MKS3PN(1)
MKS3PN(1)-2
MKS3PN(1)-5
MKS2P(1)-D
MKS2P(1)-D-2
MKS3P(1)-D
MKS3P(1)-D-2
MKS3P(1)-D-5
MKS2PN-D
MKS2PN-D-2
MKS3PN-D
MKS3PN-D-2
MKS3PN-D-5
MKS2P-V
MKS2PIN(1)
MKS2PIN(1)-2
MKS3PIN(1)
MKS3PIN(1)-2
MKS3PIN(1)-5
MKS2PI(1)-D
MKS2PI(1)-D-2
MKS3PI(1)-D
MKS3PI(1)-D-2
MKS3PI(1)-D-5
MKS2PIN-D
MKS2PIN-D-2
MKS3PIN-D
MKS3PIN-D-2
MKS3PIN-D-5
MKS2PI-V
Non Standard
Standard
Non Standard
Models with
Diode
(See note 2.)
DPDT
3PDT
Standard
Non Standard
Standard
Non Standard
Models with
LED Indicator
and Diode
DPDT
3PDT
Standard
DC
Non Standard
Standard
Non Standard
Models with
Varistor
DPDT
3PDT
Standard
AC
Non Standard
Standard
MKS2P-V-2
MKS3P-V
MKS2PI-V-2
MKS3PI-V
Non Standard
MKS3P-V-2
MKS3P-V-5
MKS2PN-V
MKS2PN-V-2
MKS3PN-V
MKS3PN-V-2
MKS3PN-V-5
MKS3PI-V-2
MKS3PI-V-5
MKS2PIN-V
MKS2PIN-V-2
MKS3PIN-V
MKS3PIN-V-2
MKS3PIN-V-5
Models with
LED Indicator
and Varistor
DPDT
3PDT
Standard
AC
Non Standard
Standard
Non Standard
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.
Example: MKS2P DC48
Rated voltage
2. The DC coil comes in two types: standard coil polarity and reverse coil polarity.
Refer to Terminal Arrangement and Internal Connections.
Example: MKS3PN1-5 DC24
Reverse coil polarity
3. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams.
■ 10A Sockets (Order Separately)
Item
Type
Model
Track-mounted
Socket
8-pin
PF083A-E
11-pin
8-pin
PF113A-E
PF083A-D
PF113A-D
PFC-A1
11-pin
Hold-down Clip
(For PF083A-E and PF113A-E)
300
General Purpose Relays MKS
Specifications
■ Ratings
Coil Ratings
Rated voltage
Rated current
Coil resistance
Must operate
voltage
Must release
voltage
Max. voltage
Power
consumption
50 Hz
443 mA
221 mA
110 mA
26.6 mA
24.2 mA
22.2 mA
13.3 mA
12.1 mA
11.5 mA
11.0 mA
224 mA
112 mA
55.8 mA
28.1 mA
13.5 mA
12.3 mA
10.8 mA
60 Hz
385 mA
193 mA
96.3 mA
23.1 mA
21.0 mA
19.3 mA
11.6 mA
10.5 mA
10.0 mA
9.6 mA
AC
6 V
3.1 Ω
80% max. of rated 30% min. of rated 110% of rated volt- Approx. 2.3 VA
voltage
voltage at 60 Hz age
25% min. of rated
voltage at 50 Hz
at 60 Hz
Approx. 2.7 VA
at 50 Hz
12 V
13.7 Ω
48.4 Ω
760 Ω
24 V
100 V
110 V
120 V
200 V
220 V
230 V
240 V
6 V
932 Ω
1,130 Ω
3,160 Ω
3,550 Ω
4,250 Ω
4,480 Ω
26.7 Ω
107 Ω
DC
15% min. of rated
voltage
Approx. 1.4 W
12 V
24 V
430 Ω
48 V
1,710 Ω
7,390 Ω
8,960 Ω
11,576 Ω
100 V
110 V
125 V
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and
15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.
4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.
Contact Ratings
Load
Resistive load
(cosφ = 1)
Inductive load
(p.f. = 0.4)
Contact mechanism
Contact material
Rated load
Single
AgSnIn
NO 10 A, 250 VAC
7 A, 250 VAC
10A, 30 VDC
NC 5 A, 250 VAC
5 A, 30 VDC
Rated carry current
10 A
Max. switching voltage
Max. switching current
Max. switching capacity
250 VAC, 250 VDC
10 A
NO 2,500 VA/300 W
NC 1,250 VA/150 W
General Purpose Relays MKS
301
■ Characteristics
Contact resistance
100 mΩ max.
Operate time
AC: 20 ms max.
DC: 30 ms max.
Release time
20 ms max.(40 ms max. for built-in diode models)
Max. operating frequency
Mechanical: 18,000 operations/hr (no load)
Electrical:1,800 operations/hr (at rated load)
Insulation resistance
Dielectric strength
100 MΩ min. (at 500 VDC)
2,500 VAC 50/60 Hz for 1 min. between coil and contacts
1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity and terminals of the same polarity
2,500 VAC 50/60 Hz for 1 min. between current-carrying parts, non-current-carrying parts, and opposite
polarity
Insulation method
Basic insulation
Impulse withstand voltage
4.5 kV between coil and contacts (with 1.2 × 50 μs impulse wave)
3.0 kV between contacts of different polarity (with 1.2 × 50 μs impulse wave)
Pollution degree
3
Rated insulation voltage
Vibration resistance
250 V
Destruction:10 to 55 Hz, 1.5 mm double amplitude
Malfunction:10 to 55 Hz, 1.0 mm double amplitude
Destruction:1,000 m/s2 (approx. 100 G)
Malfunction:100 m/s2 (approx. 10 G)
Mechanical: 5,000,000 operations min.
Electrical:100,000 operations min.
Shock resistance
Life expectancy
10 mA at 1 VDC P level: λ60=0.1 x 10-6 / ops
Operating: –40 to 60°C (with no icing or condensation)
Operating: 5% to 85%
Min. permissible load
Ambient temperature
Ambient humidity
Weight
Approx. 90 g
Note: 1. The values given above are initial values.
2. Ambient temperature of models with LED indicator is −25 to 60°C.
■ Approved Standards
UL Recognized (File No. E41515) - - Ambient Temp. = 40°C
IEC Standard/TUV Certification: IEC61810-1
(Certification No. R50104853)
Coil ratings
Contact ratings
Operations
Coil ratings
6, 12, 24, 48, N.O.
100, 110 VDC contact 10 A, 30 V DC (Resistive)
6, 12, 24, 100,
110, 200, 220,
240 VAC
Contact ratings
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
Operations
6 to 110 VDC N.O.
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
6 to 240 VAC contact 10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
N.C.
10 A, 250 V AC 50/60 Hz (Resistive) 100,000
7 A, 250 V AC 50/60 Hz (General Use)
contact 10 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
N.C.
5 A, 250 V AC 50/60 Hz (Resistive)
contact 5 A, 30 V DC (Resistive)
7 A, 250 V AC 50/60 Hz (General Use)
100,000
Note: 10A UL ratings are with no load on the other contact set.
Note: Maximum carrying current per TUV Certification is 9 A when
new MK-S relays are mounted in PF083A-E or PF113A-E
Sockets.
CSA Certified (File No. LR35535)
Coil
Number
of Poles
Contact ratings
Operations
ratings
6 to 125 VDC
6 to 240 VAC
2
3
10 A, 250 V AC (Resistive)
10 A, 30 V DC (Resistive)
7 A, 250 V AC (General Use)
100,000
10 A, 250 V AC (Resistive)
Same Polarity
100,000
10 A, 30 V DC (Resistive)
Same Polarity
7 A, 250 V AC (General Use)
Same Polarity
302
General Purpose Relays MKS
Engineering Data
■ Reference Data
Maximum Switching Power
Rated Carry Current vs. Ambient Rated Temperature
100
50
10
30
DC resistive load
UL derating curve
with NO contact
AC resistive load
with NO contact
10
5
AC inductive
load
(p.f. = 0.4)
5
3
AC resistive load
with NC contact
DC resistive
load with
NC contact
0
−40
1
10
30
50
100
300 500 1.000
−20
0
20
40
60
80
Ambient temperature (°C)
Switching voltage (V)
Note: The lower limit of the ambient operating temperature for models
with built-in operation indicators is −25°C.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Models without Test Button
Models with Lockable Test Button
34.5 max.
34.5 max.
34.5 max.
0.8
52.5 max.
34.5 max.
0.8
52.5 max.
Track Mounted Sockets
See below for Socket dimensions.
Poles
Finger-protection models
—
Maximum carry current 10 A
5 A
2 poles
PF083A-E
PF083A-D
PF083A
3 poles
PF113A-E
PF113A-D
PF113A
Note: If using the PF083A or PF113A Sockets, be sure the maximum carrying current is 5 A or less. When using finger-protection sockets, make
sure the connecting wire terminals are Y-shaped.
General Purpose Relays MKS
303
PF083A-E (Conforming to EN 50022)
PF113A-E (Conforming to EN 50022)
Terminal Arrangement
Terminal Arrangement
Eight, M3.5 × 7 sems
Eleven, M3.5 × 7 sems
7
4
7
4
52 max.
35.4
52 max.
35.4
2
3.5
33
41 max.
Mounting Holes
Mounting Holes
21 max.
3.5
2
4
34
42.8 max.
Two, M4 or two 4.5-dia. holes
Two, M4 or two 4.5-dia. holes
31 max.
33 0.2
33 0.2
PF083A-D
PF113A-D
8
Terminal Arrangement
Terminal Arrangemen
8
24 22 12 14
21
32 24 22 12
6
5
4
3
6
5.5
8
7
5 4
5.5
27
4
27
4
Eight, M4 screws
Eight, M4 screws
9
34
3
14
10
A2
2
A1
7
8
1
2
11
31
1
11
A2 21 11 A1
Mounting Holes
Two, M4 or two 4.5-dia. hole
Mounting Holes
Two, M4 or two 4.5-dia. hol
65
65
30
30
38
38
Hold-down Clips
Mounting Height with Sockets
PFC-A1
(2 pieces per set)
Three
poles
Two
poles
4.6
87.8
(See
note.)
77.8
(See
note.)
84.3
74.3
60.8
62
PF083A(-E)
PF113A(-E)
Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.
6
4.5
Mounting Tracks
PFP-100N, PFP-50N
(Conforming to EN 50022)
PFP-100N2
(Conforming to EN 50022)
16
7.3 0.15
35 0.3
4.5
4.5
27
35 0.3
29.2
1.5
24
27 0.15
1
15 25
25
25
25 15
15 25
25
25
25
**
1
15 (5)
10
10
10
10
1000 4
1000 (500)*
* The figure in parenthesis is for PFP-50N.
** A total of twelve 25 x 4.5 elliptic holes is provided with six
holes cut from each track end at a pitch of 10 mm.
304
General Purpose Relays MKS
(Bottom View)
Terminal Arrangement/Internal Connection
MKS2P(I)
MKS2P(I)-2
MKS3P(I)
MKS3P(I)-2
MKS3P(I)-5
Basic Models
(AC/DC Coil)
5
5
4
4
6
5
7
6
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
8
4
8
4
3
9
9
3
9
3
1
8
1
8
2
10
10
2
10
2
1
11
11
1
11
1
MKS2P(I)N
MKS2P(I)N-2
MKS3P(I)N
MKS3P(I)N-2
MKS3P(I)N-5
LED Indicator Type
(AC Coil)
5
5
4
4
6
5
7
3
2
3
2
6
6
7
6
7
6
5
7
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10
2
10
2
10
1
11
1
11
1
11
MKS2P(I)N
MKS2P(I)N-2
MKS3P(I)N
MKS3P(I)N-2
MKS3P(I)N-5
LED Indicator Type
(DC Coil:
Standard Polarity)
5
5
4
4
6
6
5
7
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10
2
10
2
10
1
11
1
11
1
11
MKS2P(I)N1
MKS2P(I)N1-2
MKS3P(I)N1
MKS3P(I)N1-2
MKS3P(I)N1-5
LED Indicator Type
(DC Coil:
Reverse Polarity)
5
5
4
4
6
6
5
7
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
4
8
8
4
3
9
3
9
3
9
1
8
1
8
2
10
2
10
2
10
1
11
1
11
1
11
MKS2P(I)-D
MKS2P(I)-D-2
MKS3P(I)-D
MKS3P(I)-D-2
MKS3P(I)-D-5
Diode Type
(DC Coil:
5
5
4
4
Standard Polarity)
6
6
7
5
3
2
3
2
6
7
6
7
6
7
5
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10
2
10
2
10
11
1
1
11
1
11
MKS2P(I)1-D
MKS2P(I)1-D-2
MKS3P(I)1-D
MKS3P(I)1-D-2
MKS3P(I)1-D-5
Diode Type
(DC Coil:
5
5
4
4
Reverse Polarity)
6
6
5
3
2
3
2
7
6
7
6
7
6
5
7
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10
2
10
2
10
1
11
1
11
1
11
General Purpose Relays MKS
305
MKS2P(I)N-D
MKS2P(I)N-D-2
MKS3P(I)N-D
MKS3P(I)N-D-2
MKS3P(I)N-D-5
LED Indicator and
Diode Type
(DC Coil)
5
5
4
4
6
7
6
5
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
4
8
8
4
3
9
3
9
3
9
1
8
1
8
2
10
2
10
2
10
1
11
1
11
11
1
MKS2P(I)-V
MKS2P(I)-V-2
MKS3P(I)-V
MKS3P(I)-V-2
MKS3P(I)-V-5
Varistor Type
(AC Coil)
5
5
4
4
6
6
3
2
3
2
6
7
6
7
5
7
6
5
7
5
7
4
8
4
8
4
8
3
3
9
9
3
9
1
8
1
8
2
10
2
10
2
10
1
11
1
11
11
1
MKS2P(I)N-V
MKS2P(I)N-V-2
MKS3P(I)N-V
MKS3P(I)N-V-2
MKS3P(I)N-V-5
LED Indicator and
Varistor Type
(AC Coil)
5
5
4
4
6
5
7
6
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
8
4
4
8
3
9
3
9
3
9
1
8
1
8
2
10
2
10
2
10
1
11
1
11
1
11
Safety Precautions
■ Safety Precautions for Correct Use
Installation
Recommend mounting MK-S Relay so that side with wiring diagram is facing down.
Handling
Check coil polarity when wiring LED Indicator and Diode Models.
Test Button
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON.
Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay circuits.
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the
Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only
the requirements for basic insulation are fulfilled.
306
General Purpose Relays MKS
MEMO
General Purpose Relays MKS
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11
Specifications subject to change without notice
Printed in USA
Cat. No. X301-E-1b
General Purpose Relays MKS
MKS3PN-D-5DC6 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
MKS3PN-D100VDC | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.014A (Coil), 100VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-D12VDC | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.112A (Coil), 12VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-D24VDC | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.056A (Coil), 24VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-D48VDC | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.028A (Coil), 48VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-D6VDC | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.224A (Coil), 6VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-DDC100 | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.014A (Coil), 100VDC (Coil), 1400mW (Coil), 10A (Contact), 250VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-DDC12 | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.112A (Coil), 12VDC (Coil), 1400mW (Coil), 10A (Contact), 250VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-DDC125 | OMRON | Power/Signal Relay | 获取价格 | |
MKS3PN-DDC24 | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.056A (Coil), 24VDC (Coil), 1400mW (Coil), 10A (Contact), 250VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 | |
MKS3PN-DDC48 | OMRON | Power/Signal Relay, 3PDT, Momentary, 0.028A (Coil), 48VDC (Coil), 1400mW (Coil), 10A (Contact), 250VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT | 获取价格 |
MKS3PN-D-5DC6 相关文章
- 2024-10-31
- 6
- 2024-10-31
- 6
- 2024-10-31
- 7
- 2024-10-31
- 8