MY4DC48(S) [OMRON]

Power/Signal Relay,;
MY4DC48(S)
型号: MY4DC48(S)
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay,

继电器
文件: 总20页 (文件大小:1848K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General-purpose Relay  
MY  
Versatile, Multi-featured, Miniature Power Relay  
for Sequence Control and Power Switching  
Applications  
• Models with lockable test buttons now available.  
• Multiple features available, including operation indicators (mechan-  
ical and LED indicators), lockable test button, built-in diode and CR  
(surge suppression), bifurcated contacts, etc.  
• Environment-friendly cadmium-free contacts.  
• Wide range of Sockets (PY, PYF Series) and optional parts.  
• Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A  
• Provided with nameplate.  
• RoHS Complaint.  
LR  
Ordering Information  
Relays  
Standard Coil Polarity  
Type  
Contact form  
Model  
Plug-in socket/solder terminals  
Standard with LED  
indicator  
With LED indicator and  
Without LED indicator  
lockable test button  
MY2IN  
Standard  
DPDT  
MY2N  
MY2  
MY4  
MY4Z  
---  
4PDT  
MY4N  
MY4IN  
4PDT (bifurcated)  
DPDT  
MY4ZN  
MY4ZIN  
With built-in diode  
(DC only)  
MY2N-D2  
MY4N-D2  
MY4ZN-D2  
MY2N-CR  
MY4N-CR  
MY4ZN-CR  
MY2IN-D2  
MY4IN-D2  
MY4ZIN-D2  
MY2IN-CR  
MY4IN-CR  
MY4ZIN-CR  
4PDT  
---  
4PDT (bifurcated)  
DPDT  
---  
With built-in CR  
(220/240 VAC,  
110/120 VAC only)  
---  
4PDT  
---  
4PDT (bifurcated)  
---  
Reverse Coil Polarity  
Type  
Contact form  
Model  
Plug-in socket/solder terminals  
With LED indicator  
With LED indicator and  
lockable test button  
Standard (DC only)  
DPDT  
MY2N1  
MY2IN1  
4PDT  
MY4N1  
MY4IN1  
4PDT (bifurcated)  
DPDT  
MY4ZN1  
MY4ZIN1  
MY2IN1-D2  
MY4IN1-D2  
MY4ZIN1-D2  
With built-in diode  
(DC only)  
MY2N1-D2  
MY4N1-D2  
MY4ZN1-D2  
4PDT  
4PDT (bifurcated)  
Note: 1. When ordering, add the rated coil voltage to the model number(s), followed by “(S)”. Rated coil voltages are given in the coil ratings table.  
Example: MY2 AC12(S)  
Rated coil voltage  
2. Arc barrier standard on all four-pole relays.  
3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for details.  
General-purpose Relay MY  
281  
Specifications  
Coil Ratings  
Rated voltage  
Rated current  
Coil  
Inductance  
Must  
Must  
Max.  
Power  
resistance (reference value)  
operate release  
% of rated voltage  
voltage consumption  
(approx.)  
50 Hz  
60 Hz  
Arm. OFF  
0.04 H  
Arm. ON  
AC 6 V*  
12 V  
214.1 mA  
106.5 mA  
53.8 mA  
183 mA  
91 mA  
46 mA  
12.2 Ω  
46 Ω  
180 Ω  
788 Ω  
0.08 H  
0.33 H  
1.30 H  
5.66 H  
80% max. 30% min. 110%  
1.0 to 1.2 VA  
(60 Hz)  
0.17 H  
24 V  
0.69 H  
48/50 V*  
24.7/  
25.7 mA  
21.1/  
22.0 mA  
3.22 H  
110/120 V  
220/240 V  
9.9/10.8 mA 8.4/9.2 mA  
4.8/5.3 mA 4.2/4.6 mA  
4,430 Ω  
19.20 H  
83.50 H  
32.1 H  
0.9 to 1.1 VA  
(60 Hz)  
18,790 Ω  
136.4 H  
DC 6 V*  
12 V  
151 mA  
75 mA  
39.8 Ω  
160 Ω  
636 Ω  
2,560 Ω  
11,100 Ω  
0.17 H  
0.73 H  
3.20 H  
10.60 H  
45.60 H  
0.33 H  
1.37 H  
5.72 H  
21.0 H  
86.2 H  
10% min.  
0.9 W  
24 V  
37.7 mA  
18.8 mA  
9.0/9.9 mA  
48 V*  
100/110 V  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and  
15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C.  
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).  
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re-  
sistor if required.  
5. Rated voltage denoted by “*” will be manufactured upon request. Ask your OMRON representative.  
Contact Ratings  
Item  
2-pole  
4-pole  
4-pole (bifurcated)  
Resistive load Inductive load  
Resistive load Inductive load  
Resistive load Inductive load  
(cosφ = 1)  
(cosφ = 0.4,  
(cosφ = 1)  
(cosφ = 0.4,  
(cosφ = 1)  
(cosφ = 0.4,  
L/R = 7 ms)  
L/R = 7 ms)  
L/R = 7 ms)  
Rated load  
5 A, 250 VAC  
5 A, 30 VDC  
2 A, 250 VAC  
2 A, 30 VDC  
3 A, 250 VAC  
3 A, 30 VDC  
0.8 A, 250 VAC  
1.5 A, 30 VDC  
3 A, 250 VAC  
3 A, 30 VDC  
0.8 A, 250 VAC  
1.5 A, 30 VDC  
Carry current 10 A (see note)  
Max. switching 250 VAC  
5 A (see note)  
250 VAC  
125 VDC  
voltage  
125 VDC  
Max. switching 10 A  
current  
5 A  
Max. switching 2,500 VA  
1,250 VA  
300 W  
1,250 VA  
150 W  
500 VA  
150 W  
1,250 VA  
150 W  
500 VA  
150 W  
capacity  
300 W  
Min.  
permissible  
load*  
5 VDC, 1 mA  
1 VDC, 1 mA  
1 VDC, 100 μA  
* Reference value.  
Note: Do not exceed the carry current of a Socket in use.  
282  
General-purpose Relay MY  
Characteristics  
Contact resistance  
100 mΩ max.  
20 ms max.  
Operate time  
Release time  
20 ms max.  
Max. operating frequency  
Mechanical 18,000 operations/hr  
Electrical  
1,800 operations/hr (under rated load)  
Insulation resistance  
Dielectric withstand voltage  
Vibration resistance  
1,000 MΩ min. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)  
Destruction:10 to 55 Hz, 1.0 mm double amplitude  
Malfunction:10 to 55 Hz, 1.0 mm double amplitude  
Destruction:1,000 m/s2 (approx. 100G)  
Shock resistance  
Malfunction:200 m/s2 (approx. 20G)  
Life expectancy  
Ambient temperature  
Ambient humidity  
Weight  
See the following table.  
Operating  
Operating  
-55°C to 70°C (-67°F to 158°F) with no icing (see note)  
5% to 85% RH  
Approx. 35 g  
Note: The values given above are initial values.  
Life Expectancy Characteristics  
Pole  
Mechanical life  
(at 18,000 operations/hr)  
Electrical life  
(at 1,800 operations/hr under rated load)  
2-pole  
AC:50,000,000 operations min.  
DC:100,000,000 operations min.  
500,000 operations min.  
200,000 operations min.  
100,000 operations min.  
4-pole  
4-pole (bifurcated)  
20,000,000 operations min.  
Approved Standards  
VDE, UL, CSA, CE  
(CE marking is provided only on non-PCB terminal versions)  
Precautions  
Connections  
Do not reverse polarity when connecting DC-operated Relays with  
built-in diodes or indicators or high-sensitivity DC-operated Relays.  
Mounting  
Whenever possible, mount Relays so that it is not subject to vibration  
or shock in the same direction as that of contact movement.  
General-purpose Relay MY  
283  
Engineering Data  
Maximum Switching Power  
MY2  
MY4, MY4Z  
AC resistive load  
AC inductive load  
(cosφ=0.4)  
AC resistive load  
AC inductive load  
(cosφ=0.4)  
DC resistive load  
DC resistive load  
DC inductive load  
(L/R=7 ms)  
DC inductive load  
(L/R=7 ms)  
Switching voltage (V)  
Switching voltage (V)  
Endurance  
MY2 (Resistive Loads)  
MY2 (Inductive Loads)  
10000  
5000  
10000  
5000  
3000  
3000  
250 VAC  
250 VAC  
1000  
1000  
500  
30 VDC  
30 VDC  
500  
300  
30 VDC  
30 VDC  
300  
250 VAC  
250 VAC  
100  
100  
50  
30  
50  
30  
10  
10  
Switching current (A)  
Switching current (A)  
MY4 (Resistive Loads)  
MY4 (Inductive Loads)  
10000  
5000  
10000  
5000  
3000  
3000  
250 VAC  
30 VDC  
1000  
1000  
30 VDC  
500  
300  
500  
300  
30 VDC  
30 VDC  
250 VAC  
100  
100  
250 VAC  
250 VAC  
50  
30  
50  
30  
10  
10  
Switching current (A)  
Switching current (A)  
284  
General-purpose Relay MY  
MY4Z (Resistive Loads)  
MY4Z (Inductive Loads)  
10000  
10000  
5000  
3000  
5000  
3000  
1000  
1000  
250 VAC  
30 VDC  
500  
300  
500  
300  
30 VDC  
30 VDC  
100  
100  
250 VAC  
30 VDC  
50  
30  
50  
30  
250 VAC  
250 VAC  
10  
10  
Switching Current (A)  
Switching Current (A)  
General-purpose Relay MY  
285  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
2-Pole Models  
MY2N  
2.6  
Eight, 1.2 dia. × 2.2 long holes  
0.5  
28 max.  
6.4  
36 max.  
21.5 max.  
4-Pole Models  
MY4N  
2.6  
Eight, 1.2 dia. × 2.2 long holes  
0.5  
28 max.  
36 max.  
6.4  
21.5 max.  
Models with Test Button  
MY2IN  
2.6  
Eight, 1.2 dia. × 2.2 long holes  
8
28 max.  
36 max.  
14.2  
21.5 max.  
MY4IN  
2.6  
Fourteen, 1.2 dia. × 2.2 long holes  
8
28 max.  
14.2  
36 max.  
<1.417>  
6.4  
21.5 max.  
286  
General-purpose Relay MY  
Terminal Arrangement/Internal Connections (Bottom View)  
MY2  
MY2N/MY2IN  
(AC Models)  
MY2N/MY2IN  
(DC Models)  
MY2N-D2/MY2IN-D2  
(DC Models Only)  
MY2N-CR/MY2IN-CR  
(AC Models Only)  
MY2N1/MY2IN1  
(DC Models Only)  
MY2N1-D2/MY2IN1-D2  
(DC Models Only)  
MY4(Z)  
MY4(Z)N/MY4(Z)IN  
(AC Models)  
MY4(Z)N/MY4(Z)IN  
(DC Models)  
MY4(Z)N-D/MY4(Z)IN-D2  
(DC Models Only)  
MY4(Z)N-CR/MY4(Z)IN-CR  
(AC Models Only)  
MY4(Z)N1/MY4(Z)IN1  
(DC Models Only)  
MY4(Z)N1-D2/MY4(Z)N1-D2  
(DC Models Only)  
General-purpose Relay MY  
287  
Accessories (order separately)  
Track-mounted Screwless Clamp Terminal Sockets  
Item  
Model  
4-pole  
2-pole  
Socket  
PYF14S  
PYF08S  
PYCM-08S  
Clip & release lever  
Nameplate  
PYCM-14S  
R99-11 Nameplate for MY  
Socket bridge  
PYDM-14SR  
PYDM-14SB  
PYDM-08SR  
PYDM-08SB  
Note: For complete specifications, see the datasheet at Omron's Knowledge Center on our website: www.knowledge.omron.com.  
Sockets  
Poles  
Front-connecting Back-connecting socket  
socket  
Solder terminals  
PCB terminals  
PY08-02  
(DIN-track/screw  
mounting)  
PYF08A-E  
PYF08A-N  
PYF14A-E  
PYF14A-N  
Without clip  
PY08  
With clip  
PY08-Y1  
2
4
PY14  
PY14-Y1  
PY14-02  
Socket Specifications  
Item  
Pole  
Model  
Carry current  
Dielectric withstand  
voltage  
Insulation resistance  
(see note 2)  
Screwless clamp  
terminal socket  
2
4
2
PYF08S  
10 A  
2,000 VAC, 1 min  
Less than 1,000 MΩ  
PYF14S  
5 A  
Track-mounted  
socket  
PYF08A-E  
7 A  
2,000 VAC, 1 min  
1,000 MΩ min.  
PYF08A-N (see note 3)  
PYF14A-E  
7 A (see note 4)  
4
2
4
5 A  
PYF14A-N (see note 3)  
PY08(-Y1)  
5 A (see note 4)  
7 A  
Back-connecting  
socket  
1,500 VAC, 1 min  
100 MΩ min.  
PY08-02  
PY14(-Y1)  
3 A  
PY14-02  
Note: 1. The values given above are initial values.  
2. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength.  
3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55°C.  
4. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40°C, reduce the current to 60%.  
5. The MY2(S) can be used at 70°C with a carry current of 7 A.  
Socket Hold-down Clip Pairing  
Relay type  
Poles  
Front-connecting socket  
(DIN-track/screw mounting)  
Back-connecting socket  
Solder terminals  
PCB terminals  
Socket  
Socket  
Clip  
Socket  
PY08  
Clip  
Clip  
Without 2-pole  
test button  
2
4
2
PYF08A-E  
PYF08A-N  
PYF14A-E  
PYF14A-N  
PYF08A-E  
PYF08A-N  
PYC-A1  
PYC-P  
PYC-P2  
PY08-02  
PYC-P  
PYC-P2  
Without 2-pole  
test button  
PYC-A1  
PYC-E1  
PY14  
PY08  
PYC-P  
PYC-P2  
PY14-02  
PY08-02  
PYC-P  
PYC-P2  
2-pole test but-  
ton  
PYC-P2  
PYC-P2  
288  
General-purpose Relay MY  
Mounting Plates for Sockets  
Socket model  
For 1 socket  
PYP-1  
For 18 sockets  
PYP-18  
For 36 sockets  
PYP-36  
PY08, PY14  
Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets.  
DIN Rail Track and Accessories  
Description  
Model  
Mounting rail (length = 500 mm)  
Mounting rail (length = 1,000 mm)  
End Plate  
PFP-50N  
PFP-100N, PFP-100N2  
PFP-M  
Spacer  
PFP-S  
General-purpose Relay MY  
289  
Dimensions  
Unit: mm (inch)  
Socket  
Dimensions  
Terminal arrangement/  
internal connections  
(top view)  
Mounting holes  
PYF08A-E  
Two, M3, M4, or 4.5-dia. holes  
Two, 4.2 x 5  
mounting  
holes  
Eight, M3 x 8  
sems screws  
72 max.  
(TOP VIEW)  
23 max.  
Note: Track mounting is also  
possible. Refer to page  
31 max.  
12 for supporting tracks.  
PYF14A-E  
Two, 4.2 x 5  
mounting  
holes  
Two, M3, M4, or 4.5-dia. holes  
Fourteen, M3 x 8  
sems screws  
72 max.  
(TOP VIEW)  
Note: Track mounting is also  
possible. Refer to page  
29.5 max.  
(See note)  
12 for supporting tracks.  
31 max.  
PY08/PY08-Y1  
Eight, 3 x 1.2 elliptical holes  
25.5 max.  
29.5 max.  
20 max.  
24 max.  
42 max.  
Note: The PY08-Y1 includes sections indicated by  
dotted lines.  
PY08-02  
25.5 max.  
29.5 max.  
Eight, 1.3-dia.  
holes  
22 max.  
16.5 max.  
290  
General-purpose Relay MY  
Socket  
Dimensions  
Terminal arrangement/  
internal connections  
(top view)  
Mounting holes  
PYF08A-N  
22 max.  
42  
4
12  
1
4
1
14  
5
44  
8
12  
42  
3.0 dia.  
8
5
14  
44  
3.5 dia. or M3  
18.7  
67 max.  
73  
PYF-08A-N  
41  
12  
11  
9
12  
41  
14  
9
11  
Note: Track mounting is also  
possible. Refer to page  
A2  
A2  
14  
A1  
13  
14 13  
12 for supporting tracks.  
14  
A2 A2 A1  
30 max.  
PYF14A-N  
42 32 22 12  
4
3
2
1
Two, 4.5 dia. or M4  
4
44  
8
3
2
1
42  
32  
22  
6
12  
5
8
7
34 24 14  
7
24  
14  
44  
34  
6
5
67 max.  
PYF-14A-N  
26  
21  
11  
9
41  
12  
31  
73  
10  
11  
A2  
14  
A2  
14  
A1  
13  
Note: Track mounting is also  
possible. Refer to page  
12 11 10  
9
41 31 21 11  
12 for supporting tracks.  
14 14  
A2 A2  
13  
A1  
30 max.  
29.5 max.  
(See note)  
Fourteen, 3 x 1.2 elliptical holes  
PY14/PY14-Y1  
25.5 max.  
29.5 max.  
24 max.  
20 max.  
42 max.  
Note: The PY14-Y1 includes sections indicated by  
dotted lines.  
PY14-02  
25.5 max.  
29.5 max.  
22 max.  
16.5 max.  
Fourteen, 1.3-dia.  
holes  
Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets.  
General-purpose Relay MY  
291  
Socket  
Dimensions  
Terminal arrangement/  
internal connections  
(top view)  
Mounting height (with lever)  
36.5 max.  
PYF14S  
72.6 typ.  
28.6  
31 max.  
Note: Track mounting only.  
Note: Pole-2 and pole-3 can-  
not be used with the  
MY2 type. Use pole-1  
(terminal numbers 11,  
14, 12) and pole-4  
(terminal numbers  
85 max.  
41, 44, 42).  
38.2 max.  
36.5 max.  
PYF08S  
73.6 typ.  
28.6  
23.2 max.  
Note: Track mounting only.  
85 max.  
(5.3)  
Socket Bridge  
Insulating coating  
L
1.4 dia. conductor  
(See note 1.)  
Length L (mm)  
27.5 0.3  
Model number  
Color of insulating  
coating  
Item  
Characteristic  
10 A  
Rated ON current  
Rated insulation voltage  
Temperature rise  
Dielectric strength  
PYDM-14SR  
PYDM-14SB  
PYDM-08SR  
PYDM-08SB  
Red  
Blue  
Red  
Blue  
250 VAC  
35°C max.  
1,500 VAC for 1 minute  
19.7 0.3  
Ambient operating temperature -55 to 70°C  
Note: 1. The relationship between the model number, the length L,  
3. The positions of the ends of the insulating coating must not  
and the color of the insulating coating is shown above.  
vary more than 0.5 mm.  
2. The insulating coating must be able to withstand a voltage  
of 1,500 V for 1 minute. Use either PE or PA as the material  
of the insulating coating.  
4. The characteristics of the socket bridge are shown above.  
292  
General-purpose Relay MY  
Clip and Release Levers  
P
PYCM-14S  
PYCM-08S  
16 typ.  
26.5 typ.  
21.5 typ.  
28 typ.  
6 typ.  
54.4 typ.  
6.41 typ.  
4.1 typ.  
5.4 typ.  
52.5 typ.  
3 typ.  
32.7 typ.  
29.6 typ.  
Hold-down Clips  
PYC-A1  
PYC-E1  
(2 pcs per set)  
(2 pcs per set)  
36.3  
4.5  
36.3  
4.25  
5.75  
0.1  
1.2  
4.5  
4.5  
PYC-P  
PYC-P2  
5
10  
29 max.  
28  
3.3  
38.5  
General-purpose Relay MY  
293  
Mounting Plates for Back-connecting Sockets  
PYP-1  
PYP-36  
Two, 3.4-dia. holes  
72 elliptical holes  
t=1.6  
PYP-18  
72 elliptical holes  
Mounting Track and Accessories  
DIN Rail Track  
PFP-50N/PFP-100N  
7.3 0.15  
4.5  
35 0.3  
27 0.15  
1
15 (5)  
25  
15  
25  
25  
25  
10  
10  
1000 (500) *  
Note: The figure in the parentheses is for PFP-50N.  
PFP-100N2  
16  
4.5  
29.2  
35 0.3  
27 24  
1
1.5  
25  
15  
15  
25  
25  
25  
10  
10  
1000  
End Plate  
PFP-M  
10  
6.2  
1
M4 x 8 pan head screw  
1.8  
35.3  
35.5  
50  
11.5  
1.8  
1.3  
4.8  
10  
M4 spring washer  
294  
General-purpose Relay MY  
Spacer  
PFP-S  
16  
12  
5
34.8  
44.3  
16.5  
Approved Standards  
VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
10 x 103  
2
6, 12, 24, 48/50, 100/110  
110/120, 200/220,  
220/240 VAC  
6, 12, 24, 48, 100/110,  
125 VDC  
10 A, 250 VAC (cosφ=1)  
10 A, 30 VDC (L/R=0 ms)  
100 x 103  
4
5 A, 250 VAC (cosφ=1)  
5 A, 30 VDC (L/R=0 ms)  
MY4Z AC; 50 x 103  
UL Recognized (File No. 41515)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
6 x 103  
2
6 to 240 VAC  
6 to 125 VDC  
10 A, 30 VDC (general purpose), 40°C  
10 A, 250 VAC (general purpose), 40°C  
4
5 A, 30 VDC (general purpose), 40°C (Same polarity)  
5 A, 250 VAC (general purpose), 40°C (Same polarity)  
CSA Certified (File No. LR31928)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
6 x 103  
2
6 to 240 VAC  
6 to 125 VDC  
10 A, 30 VDC  
10 A, 250 VAC  
4
5 A, 250 VAC (same polarity)  
5 A, 30 VDC (same polarity)  
LR Recognitions (File No. 98/10014)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
50 x 103  
2
6 to 240 VAC  
6 to 125 VDC  
10 A, 250 VAC (resistive)  
2 A, 250 VAC (PF0.4)  
10 A, 30 VDC (resistive)  
2 A, 30 VDC (L/R=7 ms)  
50 x 103  
4
5 A, 250 VAC (resistive)  
0.8 A, 250 VAC (PF0.4)  
5 A, 30 VDC (resistive)  
1.5 A, 30 VDC (L/R=7 ms)  
SEV Listings (File No. 99.5 50902.01)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
10 x 103  
2
6 to 240 VAC  
6 to 125 VDC  
10 A, 250 VAC  
10 A, 30 VDC  
100 x 103  
4
5 A, 250 VAC  
5 A, 30 VDC  
MY4Z AC; 50 x 103  
Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may be different from the performance char-  
acteristics individually defined in this catalog.  
2. In the interest of product improvement, specifications are subject to change.  
General-purpose Relay MY  
295  
PYF-S Installation Notes  
Tools  
A flat-blade screwdriver should be used to mount the cables.  
Applicable Screwdriver  
Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)  
Flat-blade, Parallel-tip  
2.5 dia. (3.0 mm max.)  
Flat-blade, Flared-tip  
Cannot be used.  
Examples: FACOM AEF.2.5 × 75E  
(AEF. 3 × 75E)  
VESSEL No. 9900-(-)2.5 × 75 (No. 9900-(-)3 × 100)  
WAGO 210-119  
WIHA 260/2.5 × 40  
(260/3 × 50)  
*Chamfering the tip of the driver improves insertion when used as an exclusive tool.  
Applicable Wires  
Applicable Wire Sizes  
0.2 to 1.5 mm2, AWG24 to AWG16  
Applicable Wire Type  
Solid wires, stranded wires, flexible wires, or wires with ferules can  
be used.  
(See note 1.) < 2.2 Diameter D (mm) 3.2 (3.5: see note 2.)  
Conductor diameter d (mm) or length of sides a and b (mm) 1.9  
Note: 1. If the overall diameter of the wire is less than 2.2 mm, do not  
insert the wire past the conductor. Refer to the following di-  
agrams.  
2. If the overall diameter of the wire is over 3.2 mm, it will be  
difficult to use double wiring.  
Wires with Ferules  
296  
General-purpose Relay MY  
Examples of Applicable Wires (Confirmed Using Catalog Information)  
Type of wire  
Equipment wire 2491X  
BS6004  
Conductor type  
Flexible  
Solid  
See note 1, above.  
Recommended wire sizes See note 2, above.  
0.5, 0.75, 1.0 mm2  
1.5 mm2  
0.5 mm2  
1.0 mm2  
1.5 mm2  
1.0 mm2  
Switchgear BS6231  
Switchgear BS6231  
Tri-rated control and switchgear  
Conduit  
Solid  
0.5, 0.75 mm2  
0.5, 0.75, 1.0, 1.5 mm2  
1.5 mm2  
Flexible  
Flexible  
Stranded  
Flexible  
Flexible  
Flexible  
Flexible  
UL1007  
18AWG  
16AWG  
UL1015  
18AWG, 16AWG  
UL1061  
18AWG  
18AWG  
UL1430  
16AWG  
Wiring  
Use wires of the applicable sizes specified above. The length of the  
exposed conductor should be 8 to 9 mm.  
8 to 9 mm  
Fig. 1 Exposed Conductor Length  
2. Insert the exposed conductor into the wire connection hole.  
Use the following wiring procedure.  
1. Insert the specified screwdriver into the release hole located  
beside the wire connection hole where the wire is to be inserted.  
Insert  
Wire connection holes  
Release holes  
3. Pull out the screwdriver.  
Fig. 2 Wire Connection Holes and Release Holes  
Wire connection hole  
Pull out  
Release hole  
Note: Use no more than 2 wires per terminal, 1 wire per hole.  
Insert  
Screwdriver  
Fig. 3 Section A-A of Fig. 2  
General-purpose Relay MY  
297  
Precautions  
Precautions for Connection  
Do not move the screwdriver up, down, or from side to side while it  
is inserted in the hole. Doing so may cause damage to internal  
components (e.g., deformation of the coil spring or cracks in the  
housing) or cause deterioration of insulation.  
General Precautions  
Use the clip to prevent relays floating or falling out of the socket.  
Do not use the product if it has been dropped on the ground. Drop-  
ping the product may adversely affect performance.  
Confirm that the socket is securely attached to the mounting track  
before wiring. If the socket is mounted insecurely it may fall and  
injure the operator.  
Do not insert the screwdriver at an angle. Doing so may break the  
side of socket and result in a short-circuit.  
Ensure that the socket is not charged during wiring and mainte-  
nance. Not doing so may result in electric shock.  
Do not pour water or cleansing agents on the product. Doing so  
may result in electric shock.  
Do not use the socket in locations subject to solvents or alkaline  
chemicals.  
Do not use the socket in locations subject to ultraviolet light (e.g.,  
direct sunlight). Doing so may result in markings fading, rust, corro-  
sion, or resin deterioration.  
Do not insert two or more wires in the hole. Wires may come in con-  
tact with the spring causing a temperature rise or be subject to  
sparks. (There are two wiring holes for each terminal.)  
Do not dispose of the product in fire.  
Removing from Mounting Rail  
To remove the socket from the mounting rail, insert the tip of screw-  
driver in the fixture rail, and move it in the direction shown below.  
Screwdriver  
Fixture rail  
Insert the screwdriver along the hole wall as shown below.  
Screwdriver  
If lubricating liquid, such as oil, is present on the tip of screwdriver,  
the screwdriver may fall out resulting in injury to the operator.  
Insert the screwdriver into the bottom of the hole. It may not be pos-  
sible to connect cables properly if the screwdriver is inserted incor-  
rectly.  
298  
General-purpose Relay MY  
MEMO  
General-purpose Relay MY  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
09/11  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1b  
General-purpose Relay MY  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY