NL1-SC [OMRON]

Snap Acting/Limit Switch, Momentary, 0.008A, 12VDC, Wire Terminal, Coil Spring Antenna Actuator, Panel Mount-threaded;
NL1-SC
型号: NL1-SC
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch, Momentary, 0.008A, 12VDC, Wire Terminal, Coil Spring Antenna Actuator, Panel Mount-threaded

开关
文件: 总8页 (文件大小:762K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Limit Touch Switch  
NL  
CSM_NL_DS_E_2_1  
Object Actuates Switch and Turns  
Built-in Monitor Indicator ON  
Instantaneous operation upon contact with extremely  
limited hysteresis for high-precision position detection.  
Detects minute displacement or lightweight objects with  
minimal operating force.  
Built-in LED indicator ensures easy operation monitoring.  
DC models provide versatile functions in combination  
with the S3D2 Sensor Controller.  
Be sure to read Safety Precautions on page 6 to 7 and  
Safety Precautions for All Limit Switches.  
Application Examples  
· Detection of press completion position.  
· Detection of mistakes in workpiece  
setting or removal.  
· Drill positioning.  
· Material positioning.  
· Detection of workpiece edges.  
· Detection of minute workpieces.  
Press  
Workpiece  
NL  
NL  
NL  
Paper (cloth)  
Grounding  
rod  
Grounding  
rod  
NL  
NL  
(Ground)  
· Detection of paper or cloth edge  
(using indirect grounding).  
· Displacement detection and control.  
· Thickness control of rolling plates.  
Pressure  
NL  
Paper (cloth)  
Ground side  
NL  
Roller  
Bellows  
· Detection of paper or cloth seam  
(using indirect grounding).  
NL  
Controller  
Unit  
Motor  
NL  
Controller  
Unit  
NL  
Grounding rod  
Paper (cloth)  
1
NL  
Ordering Information  
Built-in Antenna Model  
Model  
Built-in antenna model  
· Ensures high-precision positioning control.  
· Provides sufficient OT (overtravel).  
· Antenna tip withstands bending.  
Features  
· OT of 5-mm max. (overtravel)  
Coil spring  
Plunger  
Antenna  
Series  
NL1  
Power supply voltage  
12 VDC  
Model  
Model  
NL1-P  
NL1-C  
NL2  
24 VDC  
NL2-C  
NL3-C 100V  
NL2-P  
100 VAC  
NL3-P 100V  
NL3  
200 VAC  
NL3-C 200V  
NL3-P 200V  
Antenna only  
NL1-C ANTENNA ASSY (Same for NL1, NL2, and NL3)  
---  
Note: Each model is provided with a standard 1-m cable.  
Separate Antenna Model  
Model  
Separate antenna model  
Features · Antenna with 3-m extension cable is available for narrow spaces where conventional limit switches cannot be used.  
No antenna  
Plunger  
with antenna  
Coil spring with antenna  
Antenna  
Series  
NL1  
Power supply voltage  
12 VDC  
Model  
NL1-S  
NL2-S  
---  
Model  
NL1-SP  
NL2-SP  
---  
Model  
NL1-SC  
NL2-SC  
NL2  
24 VDC  
Antenna only  
NL1-SC ANTENNA (Same for NL1 and NL2)  
Note: Each model is provided with a standard 1-m cable.  
Specifications  
Item  
Model  
NL1  
NL2  
NL3  
Degree of protection  
Supply voltage  
IP60  
12 VDC  
24 VDC  
---  
Grounded object: Contact resistance of 3 kmax.  
Non-grounded object: Antenna-to-ground capacitance of 100 pF min.  
100 VAC or 200 VAC  
50/60 Hz  
Rated frequency  
Sensitivity  
Current consumption  
Leakage current  
Response time  
8 mA  
15 mA  
---  
---  
Circuit: 2 mA; Antenna: 1 mA *1  
20 ms max.  
5 ms max.  
Voltage output model: 30 mA at  
12 VDC with output  
impedance of 4.7 kΩ  
Current output model:  
24 VDC (directly switching  
resistive load of 170 mA max.)  
Thyristor output model:  
100 or 200 VAC (directly switching resistive  
load of 30 to 300 mA) *2  
Output signal  
Insulation resistance  
Dielectric strength  
0 V (black lead wire) is connected to casing  
0 V (black lead wire) is connected to casing  
100 Mmin. at 500 VDC *3  
1,500 VAC at 50/60 Hz for 1 min *3  
Pollution degree  
(operating environment)  
3 (IEC947-5-1)  
Class II  
Protection against  
electric shock  
Proof tracking index (PTI) 175  
Switch category  
Vibration resistance  
Shock resistance  
Ambient temperature  
Ambient humidity  
Weight  
D (IEC335)  
10 to 55 Hz, 1.5-mm double amplitude  
Approx. 200 m/s2 min.  
10°C to +60°C (with no icing)  
35% to 95%RH  
Approx. 370 g (NL@-C, -P) Approx. 550 g (NL@-S) Approx. 680 g (NL@-SP, -SC)  
*1. The NL3 has a capacitor and resistor for the protection of the built-in SCR. Therefore, the NL3 has leakage current.  
*2. The NL3 requires a current of 30 mA for circuit protection.  
Red (Brown)  
i
If the load current is less than 30 mA, connect the bleeder resistance R in  
Power supply  
100 VAC  
(200 VAC)  
Load  
White  
(Black)  
parallel with the load as shown below so that the total current of the load circuit will be 30 to 300 mA.  
Obtain R from the following formula.  
R
NL3  
Black (Blue)  
V
30 i  
R=  
(k)  
Make sure that the permissible power of the resistor is sufficient.  
*3. Between current-carrying and non-current-carrying metal parts  
2
NL  
Structure and Nomenclature  
Nomenclature  
Coil spring antenna  
Antenna assy  
O-ring  
Head  
LED operation  
indicator  
Rubber packing  
Cover  
(not removable)  
Mounting hole  
(with mounting pitch  
conforming to DIN standards)  
SC connector  
(not removable)  
Cable  
Principle of Operation  
The Limit Touch Switch  
constantly emits a high  
frequency. If an object  
comes in touch with the  
touch antenna, ..  
Constants of the  
Switching circuit  
Applicable to a variety of  
purposes in combination  
with a dedicated sensor  
power supply.  
oscillation circuit  
will change and  
oscillation will stop.  
will operate and  
send out output  
signals.  
Feedback  
circuit  
Antenna  
S3D Sensor  
Power Supply  
100 VAC  
(200 VAC)  
Oscillation Wave detec-  
NOT circuit  
circuit  
tion circuit  
Classification by Series and Features  
NL1  
NL2  
NL3  
Power supply  
100 VAC  
(200 VAC)  
12 VDC  
Load  
Sensor  
power supply  
Load (24 VDC, 170 mA)  
L/R=0  
Load with 30 to 300 mA  
(cos φ = 1) at 100/200 VAC  
Power supply  
S3D2:  
NL2  
NL3  
NL1  
100 to 240 VAC  
The S3D2 Controller is available  
and has a variety of functions,  
thus ensuring ease of use.  
Connects to 100/200 VAC  
power supply and directly  
switches AC loads.  
The NL2 with 24 VDC can  
directly switch the load.  
Applicable model  
Sensor Controller  
Function  
Power supply voltage  
S3D2-AK  
S3D2-BK  
S3D2-CK  
S3D2-AKD  
S3D2-CKD  
Basic operation  
NL1  
Memory and timer operation  
Timer operation  
100 to 240 VAC  
24 VDC  
Basic operation  
NL2  
Timer operation  
Contact your OMRON representative for the datasheet of the S3D2.  
3
NL  
Connections  
Output Circuit Diagrams  
NL1  
NL2  
NL3  
Brown (Red)  
Brown (Red)  
+12 VDC  
Output  
0 V  
Brown (Red)  
+24 VDC  
Load  
Black  
4.7 k  
Load  
Black  
(White)  
2.2 Ω  
Switch  
main  
circuit  
Black (White)  
Blue (Black)  
Switch  
main  
circuit  
Switch  
main  
circuit  
(White)  
100 VAC, 200 VAC  
Output  
Output  
Blue (Black)  
0 V  
Blue (Black)  
Note: The 0-V power supply side will be connected to the casing if the model is the NL1 or NL2.  
External Connection  
Sensor Power Supply (S3D2)  
Power supply  
voltage  
Applicable model  
Sensor Controller  
S3D2-AK  
The use of the S3D2 is recommended for supplying 12 VDC to the  
NL2 (or 24 VDC to the NL2) and converting the output of the NL into  
relay or open collector output in versatile timing control. The NL3 does  
not require a sensor power supply.  
Basic operation  
Memory and timer  
operation  
NL1  
S3D2-BK  
S3D2-CK  
Timer operation  
Basic operation  
Timer operation  
S3D2-AKD  
S3D2-CKD  
NL2  
S3D2 Controller Unit  
Be sure to wire the cable correctly according to the color of each lead wire. Do not wire power lines or high-tension lines alongside the  
cable.  
The use of S3D2 is recommended as a power supply to the NL1. Contact your OMRON representative for the datasheet of the S3D2.  
NL1  
NL2  
+12 VDC Brown (Red)  
Blue (Black)  
24 VDC  
0 V  
Black  
(White)  
(Output)  
OUT Black  
(White)  
0 V Blue  
Load  
(Black)  
Blue (Black)  
*
External circuit  
A maximum DC load of 170 mA  
(with no inductance or resistance).  
Can be switched directly.  
* Ground the blue (black) wire.  
7
8
9
10  
12  
11  
NL3  
Brown (Red)  
IN1  
IN2  
Black  
(White)  
NORM INV  
100 VAC or  
Load  
4
5
6
200 VAC  
(Output)  
1
2
3
Blue (Black)  
*
External circuit  
S3D2-AK  
A maximum AC load of 300 mA  
(cos φ = 1).  
Can be switched directly.  
* Be sure to ground the blue (black)  
line of the NL3.  
Note: 1. The lead wire colors of the NL have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones.  
2. The figures in the S3D2 illustration indicate the terminal numbers of the socket.  
3. Use a three-conductor cable with a minimum thickness of 0.75 mm to connect the NL and the Sensor Power Supply or other devices with no built-in contacts.  
The cable can be extended up to 100 m on condition that the cable is wired in an independent conduit.  
4
NL  
Dimensions  
(Unit: mm)  
Built-in Antenna Models  
Coil Spring  
NL1-C  
NL2-C  
Plunger  
NL1-P  
NL2-P  
NL3-P  
1.2 dia. *1  
5.3 dia.  
6 dia. *1  
5
*2  
16  
16  
NL3-C  
2
Two,  
110  
31  
12.5  
75  
+0.12  
25.8  
1
5.3  
holes  
dia.  
(15)  
0.8  
6.5  
55  
(99)  
12.5  
1
0.2  
60  
Two,  
0.12  
5.3  
dia.  
8
0.2  
holes  
60  
75  
Two, 5.3-dia.  
long holes  
(7.3)  
25 max.  
LED operation  
indicator  
8
25 max.  
Two, 5.3-dia.  
long holes  
(7.3)  
*3  
Caution label  
7-dia. Connection  
cable (1 m)  
15  
15  
30  
+0.2  
5
30  
+0.8  
40  
+0.8  
43.7  
*2  
Caution label  
7-dia. Connection  
cable (1 m)  
5
15  
15  
30  
*1. The stainless-steel plunger antenna allows a maximum  
OT (overtravel) of 5 mm.  
*2. This position is the FP (free position) of the plunger.  
*3. Use after removing the caution label.  
0.2  
30  
0.8  
0.8  
40  
43.7  
*1. The coil spring antenna is movable in any direction. Make sure  
that the angle of the antenna is within 30° to the FP (free position)  
after the antenna comes into contact with the object.  
*2. Use after removing the caution label.  
Note: 1. The force that pushes the actuator must not exceed 1.96 N.  
2. The antenna is replaceable. Contact your OMRON representative for  
details.  
Note: Do not apply a force greater than 9.8 N to the plunger.  
Separated Antenna Models  
The dimensions provided for the NL1-SP, NL2-SP, NL1-SC, and NL2-SC are the external dimensions for the antennas. The casing  
dimensions of these models are all the same as those for the coil spring or plunger models.  
No Antenna  
NL1-S  
Plunger Antenna  
NL1-SP  
NL2-S  
NL2-SP  
5
*2  
35  
(10.5)  
*3  
31  
*1  
6 dia.  
8
22.5  
16  
6
R16  
*1. The stainless-steel plunger antenna  
allows a maximum OT (overtravel)  
of 5 mm.  
*2. This position is the FP  
(free position) of the plunger.  
*3. A standard 3-m high-frequency  
coaxial cable is provided.  
7 dia. *1  
Two,  
51  
0.5  
35  
Two, M22 x 1  
mounting nuts  
Distance to  
t 2.3  
(2.3R)  
1
12  
(27)  
opposite side: 26  
thickness: 4  
4.5  
(
)
0.12  
5.3  
holes  
dia.  
20  
0.2  
16  
32  
(95)  
LED operation  
indicator  
0.2  
60  
16  
75  
Note: 1. Do not apply a force greater than 9.8 N to the plunger.  
2. Do not cut or extend the connecting cable.  
Two, 5.3-dia.  
long holes  
(7.3)  
8
25 max.  
Coil Spring Antenna  
NL1-SC  
NL2-SC  
*2  
7-dia. Connection  
15  
Caution label  
15  
30  
cable (1 m)  
0.2  
5
30  
2
90.5  
0.8  
40  
0.8  
43.7  
(10.5)  
2
31  
40.5  
8
22.5  
6
3.5  
*1. A standard 3-m high-frequency coaxial cable is provided.  
*2. Use after removing the caution label.  
*2  
*1. The coil spring antenna is movable in any  
direction. Make sure that the angle of the  
antenna is within 30° to the FP (free position)  
after the antenna comes into contact with the  
object.  
1.2 dia. *1  
*2. A standard 3-m high-frequency coaxial  
cable is provided.  
Note: 1. Make sure that the shape of the antenna is suitable to the application.  
Use the plunger antenna or coil spring antenna as shown right for the  
NL1-S or NL2-S.  
Note: 1. Do not cut or extend the connecting cable.  
2. The antenna is replaceable. Contact your OMRON representative for  
details.  
2. Do not cut or extend the connecting cable.  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
5
NL  
Safety Precautions  
Refer to Safety Precautions for All Limit Switches.  
CAUTION  
Antenna  
<Shape and Extension>  
Make sure that the antenna does not come into contact  
with the human body, otherwise an electric shock may  
be received.  
If a metal plate is used as an antenna by connecting it to the built-in  
or separated antenna of the NL, the surface area of the metal plate  
must be 200 cm2 maximum. The antenna can be extended, provided  
that the total length of the antenna is 1 m maximum and that the  
bottom of the antenna is at least 10 cm away from the ground. Refer  
to the illustrations below.  
Precautions for Correct Use  
Antenna Grounded through Sensing Object  
Fig. 1  
Fig. 2  
Fig. 3  
<Size of Sensing Object>  
Grounded Object  
Metal plate  
200cm max.  
6
5
2
1
1 m max.  
NL  
2
4
3
If the sensing object is the following grounded conductor, its size  
will not affect the operation of the NL. Check for the presence of  
insulators sticking to the sensing object or the corrosion of the  
sensing object, however, so that the ground resistance will not  
exceed 3 k.  
10 cm min.  
Ground  
NL  
NL  
1 + --- 6 1 m  
Contact with Grounded Conductor  
The sensing object is equivalently grounded through ground resistor R.  
Antenna Connection  
To connect a suitable antenna to the high-frequency coaxial cable of  
the NL@-S, perform the following steps.  
Grounded  
conductor  
3 kmax.  
Antenna  
R
Antenna  
Antenna  
High-frequency  
coaxial cable  
High-frequency  
coaxial cable  
High-frequency  
coaxial cable  
R: 3 kmax.  
Soldering  
Screwing (I)  
Screwing (II)  
The sensing object must not come into contact with the human body.  
Braided Shield  
Non-grounded Object  
The shield is connected to the casing of the NL. Pay the utmost  
attention so that the conductor connected to the antenna will not  
come into contact with the shield. Secure the shield with insulation  
tape.  
If the sensing object is the following non-grounded conductor, the  
NL will operate if the capacitance between the sensing object and  
the ground is 100 pF or more. The larger the surface area of the  
sensing object is, the higher its capacitance will be. The shorter the  
distance between the sensing object and the ground is, the higher  
the capacitance will be. Furthermore, the capacitance greatly  
varies with the ground condition (e.g., dry sand, concrete, or wet  
Insulation tape  
soil).  
Contact with Non-grounded Conductor  
The sensing object is equivalently grounded through capacitor C.  
Conductor  
Braided shield  
Non-grounded  
If the antenna cable needs to be extended, use the separated  
antenna model. Do not use a standard cable in place of the high-  
frequency coaxial cable.  
conductor  
Generally, the conductor will  
be detectable if the ambient  
humidity is 60% to 70%RH and  
the surface area of the conductor  
100 pF min.  
C
Correct  
is approximately 300 × 500 mm.  
High-frequency coaxial cable  
Antenna  
C: 100 pF min.  
NL (separated  
antenna model)  
<Conditions of Sensing Object>  
Installation  
The detection of conductors (e.g., iron, stainless steel, aluminum,  
and brass objects) poses no particular problem. A conductor  
coated with paint cannot be detected, however, because there is no  
electrical continuity between the antenna and the conductor.  
Non-conductive objects (e.g., plastic, ceramic, glass, and cloth  
objects) can be detected by grounding them indirectly.  
Incorrect  
Standard cable  
NL  
Installation  
6
NL  
<Antenna in Parallel>  
Others  
If more than one NL is used in parallel or side-by-side, make sure that  
the distance between the antennas is at least 4 cm.  
Do not disassemble the NL, otherwise the internal wiring will be  
damaged and the NL will fail to operate.  
Make sure that the conduit opening is free of foreign materials or  
cuttings.  
4 cm min.  
The sealing of the NL uses nitrile butadiene rubber (NBR), which is  
highly oil resistive. If exposed to some types of oil or chemical  
indoors or outdoors, however, the NBR may deteriorate. Contact  
your OMRON representative for details.  
Make sure that the load is connected according to the connection  
diagram. The internal circuit of the NL will break due to mistakes in  
wiring or load short-circuiting.  
NL  
4 cm min.  
NL  
NL  
NL  
<Maintenance>  
Make sure that the antenna is free of oil, dust, or rust, otherwise  
Brown (Red)  
Correct  
Power  
supply  
Black (White)  
(Output)  
the antenna may not operate.  
Load  
Application in Locations Subject to Water or Oil.  
Do not use the NL in places where water or oil (especially water-  
soluble oil) is frequently sprayed to the NL or antenna, otherwise the  
NL may malfunction.  
Blue (Black)  
Brown (Red)  
Incorrect  
Incorrect  
Black (White)(Output)  
Blue (Black)  
Power  
supply  
Grounding  
In order to maintain the operational reliability of the NL, be sure to  
ground the blue (black) wire of the power cable.  
Brown (Red)  
Power  
supply  
The blue (black) lead wire of the connection cable will be connected  
to the casing internally if the model is the NL1 or NL2. The NL1 or  
NL2 does not operate with the service power supply of the PC  
(Programmable Controller) because the negative end of the service  
power supply is not grounded. The noise immunity performance of  
the PC will be degraded if the negative end of the service power  
supply is grounded.  
Black (White)(Output)  
Blue (Black)  
Load  
Note: The lead wire colors of the NL have been changed in compliance with the  
latest applicable JIS standards. Colors in parentheses are previous ones.  
Remove the warning label on the end of the connection cable  
before wiring.  
Provided that single-phase 200 V is supplied to the NL3, if one  
phase is grounded, the power supply will be short-circuited and a  
machinery breakdown will result. Use an isolating transformer and  
ground the secondary side of the transformer instead.  
To maintain operating reliability and durability, connect the blue  
(black) line in the connecting cable to ground.  
Load Switching  
The NL3 switches AC loads. The maximum switching load varies  
with the ambient temperature as shown in the following graph of  
load characteristic curves.  
NL3 Load Characteristic Curves  
In the above case, be sure to ground the secondary side, otherwise  
the NL may not operate.  
(1)  
0.3  
Brown  
(Red)  
Black  
(2)  
(3)  
Load  
AC  
0.2  
0.1  
(4)  
(White)  
Blue  
NL3  
(Black)  
Note: The lead wire colors of the NL have been changed in compliance with the  
latest applicable JIS standards. Colors in parentheses are previous ones.  
15  
0
20  
40  
60  
Temperature (°C)  
Note: 1. Load (1) is an inductive load with a maximum repetitive operation rate  
of once per 5-minute period or resistive load.  
2. Load (2) is an inductive load with a maximum repetitive operation rate  
of 3 times per minute.  
3. Load (3) is an inductive load with a maximum repetitive operation rate  
of 30 times per minute.  
4. Load (4) is an inductive load with a maximum repetitive operation rate  
of 300 times per minute.  
5. Except for the resistive load, the characteristic curves cover repetitive  
operations in an ON-to-OFF ratio of 1:1. If the OFF period is extremely  
short in actual application, use 80% of the above values.  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

NL1-SP

Snap Acting/Limit Switch, Momentary, 0.008A, 12VDC, 5mm, Wire Terminal, Plunger Antenna Actuator, Panel Mount-threaded
OMRON

NL1000

SPECIAL-PURPOSE OPTO DEVICE
ETC

NL1008-010J

General Purpose Inductor, 0.01uH, 5%, 1 Element, SMD
TDK

NL1008-012J

General Purpose Inductor, 0.012uH, 5%, 1 Element, SMD
TDK

NL1008-018J

General Purpose Inductor, 0.018uH, 5%, 1 Element, SMD
TDK

NL1008-022J

General Purpose Inductor, 0.022uH, 5%, 1 Element, SMD
TDK

NL1008-039J

General Purpose Inductor, 0.039uH, 5%, 1 Element, SMD
TDK

NL1008-056J

General Purpose Inductor, 0.056uH, 5%, 1 Element, SMD
TDK

NL1008-082J

General Purpose Inductor, 0.082uH, 5%, 1 Element, SMD
TDK

NL1008-100J

General Purpose Inductor, 10uH, 5%, 1 Element, SMD
TDK

NL1008-101J

General Purpose Inductor, 100uH, 5%, 1 Element, SMD
TDK

NL1008-180J

General Purpose Inductor, 18uH, 5%, 1 Element, SMD
TDK