NT-ZJCAT1-EV4 [OMRON]

Programmable Terminals; 可编程终端
NT-ZJCAT1-EV4
型号: NT-ZJCAT1-EV4
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Programmable Terminals
可编程终端

文件: 总5页 (文件大小:984K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Programmable Terminals  
/
NT11 NT21  
Warranty and Limitations of Liability  
This catalog mainly provides information that is necessary for selecting suitable models, and  
does not contain precautions for correct use. Always read the precautions and other  
required information provided in product operation manuals before using the product.  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and  
workmanship for a period of one year (or other period if specified) from date of sale by  
OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED,  
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR  
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER  
OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE  
REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES,  
EXPRESS OR IMPLIED.  
The application examples provided in this catalog are for reference only. Check functions  
and safety of the equipment before use.  
Never use the products for any application requiring special safety requirements, such as  
nuclear energy control systems, railroad systems, aviation systems, medical equipment,  
amusement machines, vehicles, safety equipment, or other application involving serious risk  
to life or property, without ensuring that the system as a whole has been designed to  
address the risks, and that the OMRON products are properly rated and installed for the  
intended use within the overall equipment or system.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL  
DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH  
THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,  
NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the  
product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER  
CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE  
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND  
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE  
MODIFICATION OR REPAIR.  
NT11  
NT21  
Note: Do not use this document to operate the Unit.  
Regional Headquarters  
OMRON Corporation  
FA Systems Division H.Q.  
66 Matsumoto  
Authorized Distributor:  
OMRON EUROPE B.V.  
Wegalaan 67-69, NL-2132 JD Hoofddorp  
Mishima-city, Shizuoka 411-8511  
Japan  
The Netherlands  
Tel: (31)2356-81-300/Fax: (31)2356-81-388  
Tel: (81)55-977-9181  
Fax: (81)55-977-9045  
OMRON ELECTRONICS LLC  
1 East Commerce Drive, Schaumburg, IL 60173  
U.S.A.  
Tel: (1)847-843-7900/Fax: (1)847-843-8568  
OMRON ASIA PACIFIC PTE. LTD.  
83 Clemenceau Avenue,  
#11-01, UE Square,  
Singapore 239920  
Tel: (65)6835-3011/Fax: (65)6835-2711  
Note: Specifications subject to change without notice.  
Cat. No. V071-E1-02  
Printed in Japan  
1003-0.5M  
NT11  
Compact Size, High Performance  
Superb functionality with a compact screen size  
Bar Graphs can be Displayed  
Printout of Production Status  
High-speed NT Links  
Effective display area  
117 x 63 mm  
Two RS-232C ports  
Bar graph displays allow the progress of processes to be  
checked at a glance.  
(The bars are oriented horizontally.)  
Data such as the production status and production results  
can be printed out, leaving a record on paper which can be  
used as a daily report.  
Memory Link  
(The NT11S has a printer port. One screen only is printed.)  
Supports Memory Units  
Up to 3,999 screens  
Screen  
Line 1  
Line 2  
Line 3  
Plan  
200  
150  
350  
Prod.  
200  
Concentrated functionality  
140  
Mathematical  
functions  
350  
31 functional parts  
Recipes  
Alarm lists/histories  
Image library  
Trend graphs  
Analog meters  
Advantages From  
the Standpoint of Maintenance,  
NT20S/NT31  
data compatibility  
Password Screens for Security  
Password screens cannot be accessed unless the correct  
password is entered. This means that the operations that  
can be performed can be restricted according to the  
operator.  
NT21  
Upgraded NT Support Tool  
version (-EV4.7)  
Shares I/O comment data  
Integral Numeric Key Pad  
Bar Code Reader  
function  
Supports RS-232C/422  
The display, numeric keys, and function keys are all  
integrated into the front panel, which is convenient for  
designers. The key layout is ergonomically designed for  
ease of use.  
Adapter (connector)  
with CX-Programmer  
Symbol Manager previews  
Copy image library window data  
Individual editing of grouped parts  
Windows XP supported  
Programming Console  
function  
High-speed Host Link  
Up to 115,200 bps supported between CS1/CJ1 PLCs.  
Long-lived Backlight  
Key Titles can be Marked on the Function  
Key Sheet  
Since LEDs are used for the backlight, it is very long-lived  
and rarely needs to be changed.  
High-speed Host Link  
Long-lived Backlight  
Key titles can be marked on the function key sheet in  
accordance with the applications of the keys: the sheet can  
be taken out from the side face of the terminal.  
The front panel of the terminal has a water-withstanding  
construction.  
Display History Record Helps in Analysis of  
Machine Faults  
When the display history record function is set as a screen  
attribute, the time, the screen number, and a comment are  
recorded in the terminal's memory every time the relevant  
screen is displayed. This display history can be printed by  
issuing a print instruction from the host, and is useful for  
machine fault analysis.  
Fully Compatible  
with NT11S  
Example key titles:  
Full Area Access  
F1  
RUN  
F2  
AUT  
F3  
MAN.  
to CS1/CJ1  
Example printout  
No. Time  
Screen No Screen Comment  
F4  
STOP  
1 11/01-10:00  
1
LINE ERROR  
2 11/07-15:33 15  
3 11/11-13:56 19  
MOTOR ERROR  
COMPRESSER ERROR  
MOTOR ERROR  
Password  
Screens  
NT11  
4 11/14-09:12  
5
Simplified Ladder Programming  
Conforms to NEMA4 and IP65  
2
3
NT21  
Versatile I/O and Large-capacity  
Screen Memory in a Space-saving Size  
Upgraded NT Support Tool Version (-  
EV4.7)  
Highly Reliable Hardware  
Small Size, Large Screen  
Long, Maintenance-Free Life (50,000 h)  
Conforms to International Standards  
Enhanced Editing Functions  
The LCD screen is larger than the OMRON NT20S  
(increased from 256 x 128 dots to 260 x 140 dots), but the  
external dimensions and panel cut-out size are the same.  
•I/O comments in the I/O tables of the CX-Programmer can  
be used directly.  
•Symbol Manager previews  
are supported.  
This function makes it  
The NT21 conforms to the EC Directives, as well as UL,  
cULus (Class 1 Div2), and C-Tick.  
The front panel has an enclosure rating equivalent to IP65F.  
possible to preview symbols  
(parts created from graphics  
data).  
•Parts can be copied by drag &  
drop operations of image,  
library, or mark data.  
•The properties of grouped  
parts can be edited without  
having to ungroup them.  
•Because NT20S and NT31  
screen data is compatible  
NT Support Tool  
CX-Programmer  
CX-Server  
Larger  
screen  
System and screen data can be stored in  
NT21 Flash Memory.  
I/O comment data  
I/O comments for designated PLC addresses can be  
used directly, with no need for CSV file conversion.  
Function Support Equivalent to That  
of a Mid-size Operator Interface  
Two RS-232C Ports  
Two RS-232C ports in the NT21 (compared with one in the  
NT20S) enable simultaneous connection of a PLC, Bar  
Code Reader, and NT Support Tool (connectable to serial  
port A only).  
with the NT21, existing software assets can be utilized  
to greatly reduce the number of design steps.  
Note: Some data revisions may be required due to size differences.  
•Windows XP supported.  
Recipe Function  
Parts tables on the PT  
NT21  
screen can be used to set  
multiple word data in  
NT Support Tool  
(screen creation/transfer)  
records, which can then  
be written to the PLC by a  
simple PT touch panel operation. For example, the setting  
parameters for separate models can be edited on the PT,  
then written to or read from the PLC.  
RS-232C  
Comparison with the NT11  
RS-232C  
Model  
NT11  
NT11S  
NT21  
NT20S  
PLC (host)  
Basic  
performance  
Dimensions  
218 x 113 x 38.2 mm (H x W x D)  
190 x 110 x 53.5 mm (H x W x D)  
260 x 140 dots  
(5.2 inches)  
256 x 128 dots  
(4.91 inches)  
160 x 64 dots (4.24 inches)  
100 x 40 mm  
Resolution  
Effective display area  
Display color  
117 x 63 mm  
112 x 56 mm  
Black & white (with blue mode)  
178.5 x 100.5 mm  
Alarm List/History(*)  
Black & white (with Yellow mode)  
204.2 x 99.8 mm  
Plenty of Capacity for Saving Graphic Screens  
An alarm message can be  
displayed in response to  
PLC bit status, and the  
content and time of the  
message can be stored as  
an alarm history.  
Panel cut-out size (W x H)  
Max. number of  
registered screens  
250  
3,999  
500  
With 512 Kbytes of memory  
capacity, there is more than  
ample space for storing screen  
data.  
Screen data capacity  
Function keys  
32 KB  
512 KB  
None  
None  
96 KB  
None  
None  
4
*C500-BAT08 Battery  
Numeric Keys, Cursor Keys, Function Keys  
Other Keys  
(sold separately) required.  
Display  
Rectangles, polygons,  
arcs, sectors  
None  
Supported  
Supported  
None  
None  
elements  
Painting out  
None  
None  
None  
None  
None  
None  
Programming Console Function  
Image/library displays  
Analog meters  
Trend graphs  
256 positions per screen  
50 positions per screen  
1 position per screen  
1 position per screen  
4 positions per screen  
1 position per screen  
Supported  
None  
None  
None  
None  
None  
None  
None  
Abundant  
graphic screen  
storage  
The NT21 is equipped with many of the same functions as  
the SYSMAC PLC Programming Console.  
Broken line graphs  
Alarm lists/histories  
Recipes  
Versatile Communications  
NT21  
None  
None  
Programming Console  
function  
Special  
functions  
Interlocks  
In addition to the Host Link and 1:1 NT Link  
communications, the NT21 supports high-speed 1:N NT  
Links and Memory Link communications.  
Math equations: Max. 256  
(arithmetic functions,  
logic operations,  
Mathematical  
Function  
PLC (host)  
None  
None  
None  
None  
bit manipulations,  
comparison operations)  
RS-232C  
(Executes functions  
equivalent to C200H-PR027  
and CS1 Programming  
Consoles.)  
Programming  
Console function  
NT21  
NT21  
Mathematical Functions  
High-quality font  
Memory Unit  
Supported  
None  
None  
None (Emergency transfer mode)*  
Supported  
None  
RS-232C  
Up to 256 math equations can be stored in the PT  
processing table to allow automatic PT processing, and  
the results can be written to the numeral memory table or  
other destinations. This makes it possible to perform  
scaling and other mathematical operations automatically  
in the PT.  
Backlight service life  
50,000 hours min.  
10,000 hours min.  
None  
50,000 hours min.  
10,000 hours min.  
RS-232C  
Personal  
computer  
(host)  
Memory  
Link  
PLC (host)  
Communications  
Via RS-232C  
communications  
Memory Links  
Supported  
High-speed  
Bar Code Reader  
connection  
1:N NT Links  
None  
9,600/19,200  
Supported  
None  
Host Link Speed  
9,600/19,200  
9,600/19,200  
Up to 115,200  
Emergency transfer mode: When power to the NT11 is turned ON with DIP switch pin 3 turned ON, data transfer mode can be entered directly without any other operation.  
*
5
4
NT21  
NT11  
NT11 General Specifications  
Special Features  
NT21 General Specifications  
Display Specifications  
Item  
Specification  
Monochrome STN LCD  
Number of dots (resolution) 260 dots horizontally x 140 dots vertically  
Item  
Specification  
Item  
Specification  
Item  
Specification  
Display device  
24 VDC  
Printing of display history data  
Printing of daily reports (printing format registered by the users)  
15%  
Printing function  
Allowable power  
Power consumption  
Noise resistance  
Effective display area  
Viewing angle  
Display color  
117 mm horizontally x 63 mm vertically  
Conforms to IEC61000-4-4. Power supply line: 2 kV  
2 acceleration,  
Maintenance  
functions  
Display  
panel  
˚
˚
Vibration resistance  
Shock resistance  
Noise resistance  
Vibration resistance  
Shock resistance  
Conforms to IEC61000-4-4, 2K (power lines)  
Simple communications confirmation.  
Black & white (with blue mode)  
10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with  
Service life  
50,000 hours min. (until contrast reduced to 50%)  
Peak acceleration 15 G,  
2
9.8 m/s acceleration for 30 min in each of X, Y, and Z directions  
Can be set to turn OFF in 1 to 255 min or to  
remain ON with screen saver  
NT11 Product Configurations  
Automatic turn-OFF  
2
147 m/s 3 times in each of X, Y, and Z directions  
Ambient operating  
temperature  
˚
Product  
Specification  
Model  
Ambient operating  
temperature  
50,000 hours min. (at room temperature,  
until brightness is reduced to 50%)  
0 to +50˚C  
Backlight  
(white cold cathode  
tube)  
Service life  
Host link direct  
Ten-key type (frame color: beige)  
Ten-key type (frame color: black)  
NT11-SF121-EV1  
NT11-SF121B-EV1  
˚
connection,  
NT link method  
Terminal*  
Ambient operating  
humidity  
Replacement Non-replaceable  
35 to 85% RH (with no condensation)  
No corrosive gasses.  
Ambient operating  
humidity  
˚C)  
CD-ROM (for Windows 95, 98,  
Me, XP, NT, 2000)  
NT-ZJCAT1-EV4  
Support Software  
Function key sheet  
Operating  
environment  
190 x 110 x 53.5 mm (W x H x D)  
(thickness inside panel: 49.0 mm)  
Panel Specifications  
Dimensions  
10 sheets for replacement for beige NT11-CKF01  
10 sheets for replacement for black NT11-CKF01B  
Storage temperature –20 to +70˚C (with no freezing)  
Item  
Specification  
91 (13 horizontally x 7 vertically)  
Pressure-sensitive  
Enclosure ratings  
Weight  
Front panel operating section: Equivalent to IP65F, NEMA 4.*  
0.6 kg max.  
Enclosure ratings  
Weight  
Front panel: Equivalent to IP65, NEMA4  
1.0 kg max.  
Number of switches  
*
Input  
Touch  
panel  
Usage may not be possible in places where the unit would be exposed to oil for long periods.  
and a flash ROM that downloads the system program.  
Connecting cables with the PLC and NTST are the same as those for the NT21.  
Please refer to the next page.  
*
1 N max.  
*
Display Capacity  
Life expectancy  
1 million operations min.  
Display/Panel Specifications  
Note: In order to improve the performance of displays, liquid crystal devices may be ch  
Item  
Specification  
With overlapping screens,  
Outside Dimensions  
External Interface Specifications  
Fixed displays  
Item  
Specification  
Backlight  
(Graphics:  
the total is  
524,280 per screen  
Communications method  
Serial port A  
Serial port B  
Not supported  
Supported  
203  
Dot matrix of STN liquid  
NT Support Tool  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Graphics  
Marks  
rectangles, circles,  
• LED  
Host Link  
• Number of dots: 160 x 64  
• Effective display area:  
100 x 40 mm  
• Life expectancy: 50,000 hours  
minimum  
• Automatic turn-off: can be set  
to turn off in 10 minutes or  
1 hour, or to remain on.  
1:1 NT Link  
Supported  
Display screen  
PLC  
1:N NT Links  
Supported  
Character string  
displays  
256 positions per screen, max.  
1,024 display elements for overlapping screens  
• Life expectancy: 50,000 hours  
minimum  
• View angle (left/right direction):  
20  
NT Link, PT Programming Console function  
Supported  
Graph displays  
Analog meters  
50 positions per screen, capable of displaying signs and percentages  
50 positions per screen, capable of displaying signs and percentages  
SBC/personal computer  
Bar Code Reader  
Memory Links  
Supported  
Not supported  
One frame per screen, 50 items per frame  
(8 items max. for data logging)  
Indicators  
Switch  
Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector),  
which can be connected only to serial port B. (RS-485 connections must use 1:N NT Links.)  
Trend graphs  
• RUN indicator (Green LED): Lit during operation  
• Life expectancy: 1 million operations minimum  
*
Display  
elements  
One frame per screen, 256 items per frame,  
260 points per item  
Broken line graphs  
113  
98  
NT21 Standard Models  
Lamps  
256 positions per screen  
256 positions per screen  
Product  
Specification  
Model number  
Display Capacity  
Image library images  
Touch switches  
NT21  
Programmable  
Terminal  
Frame color: beige NT21-ST121-E  
Note: In order to improve the performance of displays, liquid crystal devices may be changed  
Monochrome STN  
without notice.  
256 positions per screen  
Total of 256 positions  
Support Tool Windows 95, 98, Me, NT, or 2000  
For screen transfer  
NT-ZJCAT1-EV4  
XW2Z-S002  
CD-ROM  
Item  
Specification  
for both numerical and  
218  
Normal characters (8 x 16 dots): Alphanumerics and symbols  
Marks (8 x 16 dots): User-defined, 64 max.  
thumbwheel settings  
26 positions per screen  
256 positions per screen  
Display characters  
38.2  
Cable length: 2 m XW2Z-200T  
PT: 9-pin  
Number of  
characters displayed  
PLC: 9-pin  
Normal-size: 20 horizontally x 4 lines vertically max.  
Double width  
Panel Plate thickness: 1.6 to 4.8 mm  
Recommended panel cutout:  
Cables  
Cable length: 2 m XW2Z-200S  
Cable length: 5 m XW2Z-500S  
PT: 9-pin  
PLC: 25-pin  
For  
PLC  
connection  
Recipes  
One position per screen  
Character  
string  
displays  
PT: 9-pin  
8 positions per screen  
Normal screens  
Displays screens registered as normal  
PLC: Mini-peripheral  
Cable length: 5 m XW2Z-500T-2  
A maximum of eight screens can be displayed overlapping each other.  
Up to three window screens can be displayed.  
Numeral  
Display  
elements  
Reflection Protective Sheets Display area only (5 sheets) NT20M-KBA04  
8 positions per screen  
4 positions per screen  
Windows  
Screen  
types  
98.8 +0.5  
Chemical-resistive Cover  
Battery  
Silicon cover  
NT20S-KBA01  
C500-BAT08  
0
Display history screens Order of occurrence (1,024 screens max.), order of frequency (255 times max.)  
Graph  
For alarm lists/histories  
System startup  
screen  
Displayed when powering ON (or resetting ) the PT,  
and when switching to RUN mode.  
Options  
For screen and system  
data transfer  
NT-MF161  
Memory Unit  
Numeral  
settings  
Programming  
Console screen  
Emulates PLC Programming Console functions,  
capable of being called from RUN mode.  
RS-232C/422A Adapter  
Connector Kit  
NS-AL002  
Screen  
attributes history  
204.2 +0.5  
Order of frequency, 256 screens  
XM2S-0911-S003  
0
Buzzer, display history, normal background colors,  
backlight mode, local windows  
Screen attributes  
Max. number of  
Ensures security: screens for which this attribute is set can  
only be displayed if the correct password is input.  
screen  
Dimensions  
3,999  
Rear face  
Menu  
screen  
178  
Four items per screen  
0:  
1 to 3999: User registered screens  
(normal, overlapping, windows)  
System startup screen  
No display  
Number  
of  
screens  
Screen types  
Normal screen: Displays screen registered as normal.  
250  
100 122  
53.5  
9000:  
9001:  
9002:  
9020:  
Max. number of  
registered screens  
Screen number  
Display history screens, order of occurrence  
Display history screens, order of frequency  
Programming Console screen  
Transfer screen data created using an IBM PC/AT personal  
computer to the PT.  
Screen registration  
method  
4.5  
39 min.  
9999:  
Return to previous screen designation  
Screen saving  
method  
Saved to flash memory: 32 KB (downloading method)  
By transferring screen data from the NT Support Tool  
to the PT via serial communications  
110  
Screen registration  
method  
By mounting the Memory Unit and downloading  
(automatic/manual transfer) data to the PT  
Saving screen data  
Flash memory (PT internal image memory)  
15.5  
28  
142  
190  
Panel thickness: 1.6 to 4.8 mm  
178.5 +0.5  
19.5  
/
x 100.5  
/
0 mm (W x H)  
52.5  
6
Cat. No. V071-E1-02  
2007.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2007 All Rights Reserved.  

相关型号:

NT/N03BS2775

BUNSENBRENNERSCHLAUCH D4.5MM L10M
ETC

NT/N05BS2775

BUNSENBRENNERSCHLAUCH D8MM L10M
ETC

NT/N06.5BS2775

BUNSENBRENNERSCHLAUCH D8MM L10M
ETC

NT/N10BS2775

BUNSENBRENNERSCHLAUCH D14MM L10M
ETC

NT0310052

Circuit Protection Thermistors
AMETHERM

NT0310052-A

Circuit Protection Thermistors
AMETHERM

NT0310052-B

Circuit Protection Thermistors
AMETHERM

NT0310152

Circuit Protection Thermistors
AMETHERM

NT0310269

Circuit Protection Thermistors
AMETHERM

NT0310391

Circuit Protection Thermistors
AMETHERM

NT0312152

Circuit Protection Thermistors
AMETHERM

NT0312391

Circuit Protection Thermistors
AMETHERM