Programmable Terminals
/
NT11 NT21
Warranty and Limitations of Liability
This catalog mainly provides information that is necessary for selecting suitable models, and
does not contain precautions for correct use. Always read the precautions and other
required information provided in product operation manuals before using the product.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and
workmanship for a period of one year (or other period if specified) from date of sale by
OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED,
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER
OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE
REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED.
The application examples provided in this catalog are for reference only. Check functions
and safety of the equipment before use.
Never use the products for any application requiring special safety requirements, such as
nuclear energy control systems, railroad systems, aviation systems, medical equipment,
amusement machines, vehicles, safety equipment, or other application involving serious risk
to life or property, without ensuring that the system as a whole has been designed to
address the risks, and that the OMRON products are properly rated and installed for the
intended use within the overall equipment or system.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH
THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the
product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER
CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
NT11
NT21
Note: Do not use this document to operate the Unit.
Regional Headquarters
OMRON Corporation
FA Systems Division H.Q.
66 Matsumoto
Authorized Distributor:
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
Mishima-city, Shizuoka 411-8511
Japan
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Tel: (81)55-977-9181
Fax: (81)55-977-9045
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
Singapore 239920
Tel: (65)6835-3011/Fax: (65)6835-2711
Note: Specifications subject to change without notice.
Cat. No. V071-E1-02
Printed in Japan
1003-0.5M
NT11
Compact Size, High Performance
Superb functionality with a compact screen size
Bar Graphs can be Displayed
Printout of Production Status
High-speed NT Links
Effective display area
117 x 63 mm
Two RS-232C ports
Bar graph displays allow the progress of processes to be
checked at a glance.
(The bars are oriented horizontally.)
Data such as the production status and production results
can be printed out, leaving a record on paper which can be
used as a daily report.
Memory Link
(The NT11S has a printer port. One screen only is printed.)
Supports Memory Units
Up to 3,999 screens
Screen
Line 1
Line 2
Line 3
Plan
200
150
350
Prod.
200
Concentrated functionality
140
Mathematical
functions
350
31 functional parts
•Recipes
•Alarm lists/histories
•Image library
•Trend graphs
•Analog meters
Advantages From
the Standpoint of Maintenance,
NT20S/NT31
data compatibility
Password Screens for Security
Password screens cannot be accessed unless the correct
password is entered. This means that the operations that
can be performed can be restricted according to the
operator.
NT21
Upgraded NT Support Tool
version (-EV4.7)
•Shares I/O comment data
Integral Numeric Key Pad
Bar Code Reader
function
Supports RS-232C/422
The display, numeric keys, and function keys are all
integrated into the front panel, which is convenient for
designers. The key layout is ergonomically designed for
ease of use.
Adapter (connector)
with CX-Programmer
•Symbol Manager previews
•Copy image library window data
•Individual editing of grouped parts
•Windows XP supported
Programming Console
function
High-speed Host Link
Up to 115,200 bps supported between CS1/CJ1 PLCs.
Long-lived Backlight
Key Titles can be Marked on the Function
Key Sheet
Since LEDs are used for the backlight, it is very long-lived
and rarely needs to be changed.
High-speed Host Link
Long-lived Backlight
Key titles can be marked on the function key sheet in
accordance with the applications of the keys: the sheet can
be taken out from the side face of the terminal.
The front panel of the terminal has a water-withstanding
construction.
Display History Record Helps in Analysis of
Machine Faults
When the display history record function is set as a screen
attribute, the time, the screen number, and a comment are
recorded in the terminal's memory every time the relevant
screen is displayed. This display history can be printed by
issuing a print instruction from the host, and is useful for
machine fault analysis.
Fully Compatible
with NT11S
Example key titles:
Full Area Access
F1
RUN
F2
AUT
F3
MAN.
to CS1/CJ1
Example printout
No. Time
Screen No Screen Comment
F4
STOP
1 11/01-10:00
1
LINE ERROR
2 11/07-15:33 15
3 11/11-13:56 19
MOTOR ERROR
COMPRESSER ERROR
MOTOR ERROR
Password
Screens
NT11
4 11/14-09:12
5
Simplified Ladder Programming
Conforms to NEMA4 and IP65
2
3
NT21
Versatile I/O and Large-capacity
Screen Memory in a Space-saving Size
Upgraded NT Support Tool Version (-
EV4.7)
Highly Reliable Hardware
Small Size, Large Screen
Long, Maintenance-Free Life (50,000 h)
Conforms to International Standards
Enhanced Editing Functions
The LCD screen is larger than the OMRON NT20S
(increased from 256 x 128 dots to 260 x 140 dots), but the
external dimensions and panel cut-out size are the same.
•I/O comments in the I/O tables of the CX-Programmer can
be used directly.
•Symbol Manager previews
are supported.
This function makes it
The NT21 conforms to the EC Directives, as well as UL,
cULus (Class 1 Div2), and C-Tick.
The front panel has an enclosure rating equivalent to IP65F.
possible to preview symbols
(parts created from graphics
data).
•Parts can be copied by drag &
drop operations of image,
library, or mark data.
•The properties of grouped
parts can be edited without
having to ungroup them.
•Because NT20S and NT31
screen data is compatible
NT Support Tool
CX-Programmer
CX-Server
Larger
screen
System and screen data can be stored in
NT21 Flash Memory.
I/O comment data
I/O comments for designated PLC addresses can be
used directly, with no need for CSV file conversion.
Function Support Equivalent to That
of a Mid-size Operator Interface
Two RS-232C Ports
Two RS-232C ports in the NT21 (compared with one in the
NT20S) enable simultaneous connection of a PLC, Bar
Code Reader, and NT Support Tool (connectable to serial
port A only).
with the NT21, existing software assets can be utilized
to greatly reduce the number of design steps.
Note: Some data revisions may be required due to size differences.
•Windows XP supported.
Recipe Function
Parts tables on the PT
NT21
screen can be used to set
multiple word data in
NT Support Tool
(screen creation/transfer)
records, which can then
be written to the PLC by a
simple PT touch panel operation. For example, the setting
parameters for separate models can be edited on the PT,
then written to or read from the PLC.
RS-232C
Comparison with the NT11
RS-232C
Model
NT11
NT11S
NT21
NT20S
PLC (host)
Basic
performance
Dimensions
218 x 113 x 38.2 mm (H x W x D)
190 x 110 x 53.5 mm (H x W x D)
260 x 140 dots
(5.2 inches)
256 x 128 dots
(4.91 inches)
160 x 64 dots (4.24 inches)
100 x 40 mm
Resolution
Effective display area
Display color
117 x 63 mm
112 x 56 mm
Black & white (with blue mode)
178.5 x 100.5 mm
Alarm List/History(*)
Black & white (with Yellow mode)
204.2 x 99.8 mm
Plenty of Capacity for Saving Graphic Screens
An alarm message can be
displayed in response to
PLC bit status, and the
content and time of the
message can be stored as
an alarm history.
Panel cut-out size (W x H)
Max. number of
registered screens
250
3,999
500
With 512 Kbytes of memory
capacity, there is more than
ample space for storing screen
data.
Screen data capacity
Function keys
32 KB
512 KB
None
None
96 KB
None
None
4
*C500-BAT08 Battery
Numeric Keys, Cursor Keys, Function Keys
Other Keys
(sold separately) required.
Display
Rectangles, polygons,
arcs, sectors
None
Supported
Supported
None
None
elements
Painting out
None
None
None
None
None
None
Programming Console Function
Image/library displays
Analog meters
Trend graphs
256 positions per screen
50 positions per screen
1 position per screen
1 position per screen
4 positions per screen
1 position per screen
Supported
None
None
None
None
None
None
None
Abundant
graphic screen
storage
The NT21 is equipped with many of the same functions as
the SYSMAC PLC Programming Console.
Broken line graphs
Alarm lists/histories
Recipes
Versatile Communications
NT21
None
None
Programming Console
function
Special
functions
Interlocks
In addition to the Host Link and 1:1 NT Link
communications, the NT21 supports high-speed 1:N NT
Links and Memory Link communications.
Math equations: Max. 256
(arithmetic functions,
logic operations,
Mathematical
Function
PLC (host)
None
None
None
None
bit manipulations,
comparison operations)
RS-232C
(Executes functions
equivalent to C200H-PR027
and CS1 Programming
Consoles.)
Programming
Console function
NT21
NT21
Mathematical Functions
High-quality font
Memory Unit
Supported
None
None
None (Emergency transfer mode)*
Supported
None
RS-232C
Up to 256 math equations can be stored in the PT
processing table to allow automatic PT processing, and
the results can be written to the numeral memory table or
other destinations. This makes it possible to perform
scaling and other mathematical operations automatically
in the PT.
Backlight service life
50,000 hours min.
10,000 hours min.
None
50,000 hours min.
10,000 hours min.
RS-232C
Personal
computer
(host)
Memory
Link
PLC (host)
Communications
Via RS-232C
communications
Memory Links
Supported
High-speed
Bar Code Reader
connection
1:N NT Links
None
9,600/19,200
Supported
None
Host Link Speed
9,600/19,200
9,600/19,200
Up to 115,200
Emergency transfer mode: When power to the NT11 is turned ON with DIP switch pin 3 turned ON, data transfer mode can be entered directly without any other operation.
5
4
NT21
NT11
NT11 General Specifications
Special Features
NT21 General Specifications
Display Specifications
Item
Specification
Monochrome STN LCD
Number of dots (resolution) 260 dots horizontally x 140 dots vertically
Item
Specification
Item
Specification
Item
Specification
Display device
24 VDC
Printing of display history data
Printing of daily reports (printing format registered by the users)
15%
Printing function
Allowable power
Power consumption
Noise resistance
Effective display area
Viewing angle
Display color
117 mm horizontally x 63 mm vertically
Conforms to IEC61000-4-4. Power supply line: 2 kV
2 acceleration,
Maintenance
functions
Display
panel
Vibration resistance
Shock resistance
Noise resistance
Vibration resistance
Shock resistance
Conforms to IEC61000-4-4, 2K (power lines)
Simple communications confirmation.
Black & white (with blue mode)
10 to 57 Hz with 0.075 mm amplitude and 57 to 150 Hz with
Service life
50,000 hours min. (until contrast reduced to 50%)
Peak acceleration 15 G,
2
9.8 m/s acceleration for 30 min in each of X, Y, and Z directions
Can be set to turn OFF in 1 to 255 min or to
remain ON with screen saver
NT11 Product Configurations
Automatic turn-OFF
2
147 m/s 3 times in each of X, Y, and Z directions
Ambient operating
temperature
Product
Specification
Model
Ambient operating
temperature
50,000 hours min. (at room temperature,
until brightness is reduced to 50%)
0 to +50˚C
Backlight
(white cold cathode
tube)
Service life
Host link direct
Ten-key type (frame color: beige)
Ten-key type (frame color: black)
NT11-SF121-EV1
NT11-SF121B-EV1
connection,
NT link method
Terminal*
Ambient operating
humidity
Replacement Non-replaceable
35 to 85% RH (with no condensation)
No corrosive gasses.
Ambient operating
humidity
˚C)
CD-ROM (for Windows 95, 98,
Me, XP, NT, 2000)
NT-ZJCAT1-EV4
Support Software
Function key sheet
Operating
environment
190 x 110 x 53.5 mm (W x H x D)
(thickness inside panel: 49.0 mm)
Panel Specifications
Dimensions
10 sheets for replacement for beige NT11-CKF01
10 sheets for replacement for black NT11-CKF01B
Storage temperature –20 to +70˚C (with no freezing)
Item
Specification
91 (13 horizontally x 7 vertically)
Pressure-sensitive
Enclosure ratings
Weight
Front panel operating section: Equivalent to IP65F, NEMA 4.*
0.6 kg max.
Enclosure ratings
Weight
Front panel: Equivalent to IP65, NEMA4
1.0 kg max.
Number of switches
Input
Touch
panel
Usage may not be possible in places where the unit would be exposed to oil for long periods.
and a flash ROM that downloads the system program.
Connecting cables with the PLC and NTST are the same as those for the NT21.
Please refer to the next page.
1 N max.
Display Capacity
Life expectancy
1 million operations min.
Display/Panel Specifications
Note: In order to improve the performance of displays, liquid crystal devices may be ch
Item
Specification
With overlapping screens,
Outside Dimensions
External Interface Specifications
Fixed displays
Item
Specification
Backlight
(Graphics:
the total is
524,280 per screen
Communications method
Serial port A
Serial port B
Not supported
Supported
203
Dot matrix of STN liquid
NT Support Tool
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Graphics
Marks
rectangles, circles,
• LED
Host Link
• Number of dots: 160 x 64
• Effective display area:
100 x 40 mm
• Life expectancy: 50,000 hours
minimum
• Automatic turn-off: can be set
to turn off in 10 minutes or
1 hour, or to remain on.
1:1 NT Link
Supported
Display screen
PLC
1:N NT Links
Supported
Character string
displays
256 positions per screen, max.
1,024 display elements for overlapping screens
• Life expectancy: 50,000 hours
minimum
• View angle (left/right direction):
20
NT Link, PT Programming Console function
Supported
Graph displays
Analog meters
50 positions per screen, capable of displaying signs and percentages
50 positions per screen, capable of displaying signs and percentages
SBC/personal computer
Bar Code Reader
Memory Links
Supported
Not supported
One frame per screen, 50 items per frame
(8 items max. for data logging)
Indicators
Switch
Connection via RS-422A/485 is possible using the NS-AL002 RS-232C/422A Adapter (connector),
which can be connected only to serial port B. (RS-485 connections must use 1:N NT Links.)
Trend graphs
• RUN indicator (Green LED): Lit during operation
• Life expectancy: 1 million operations minimum
Display
One frame per screen, 256 items per frame,
260 points per item
Broken line graphs
113
98
NT21 Standard Models
Lamps
256 positions per screen
256 positions per screen
Product
Specification
Model number
Display Capacity
Image library images
Touch switches
NT21
Programmable
Terminal
Frame color: beige NT21-ST121-E
Note: In order to improve the performance of displays, liquid crystal devices may be changed
Monochrome STN
without notice.
256 positions per screen
Total of 256 positions
Support Tool Windows 95, 98, Me, NT, or 2000
For screen transfer
NT-ZJCAT1-EV4
XW2Z-S002
CD-ROM
Item
Specification
for both numerical and
218
Normal characters (8 x 16 dots): Alphanumerics and symbols
Marks (8 x 16 dots): User-defined, 64 max.
thumbwheel settings
26 positions per screen
256 positions per screen
Display characters
38.2
Cable length: 2 m XW2Z-200T
PT: 9-pin
Number of
characters displayed
PLC: 9-pin
Normal-size: 20 horizontally x 4 lines vertically max.
Double width
Panel Plate thickness: 1.6 to 4.8 mm
Recommended panel cutout:
Cables
Cable length: 2 m XW2Z-200S
Cable length: 5 m XW2Z-500S
PT: 9-pin
PLC: 25-pin
For
PLC
connection
Recipes
One position per screen
Character
string
displays
PT: 9-pin
8 positions per screen
Normal screens
Displays screens registered as normal
PLC: Mini-peripheral
Cable length: 5 m XW2Z-500T-2
A maximum of eight screens can be displayed overlapping each other.
Up to three window screens can be displayed.
Numeral
Display
elements
Reflection Protective Sheets Display area only (5 sheets) NT20M-KBA04
8 positions per screen
4 positions per screen
Windows
Screen
types
98.8 +0.5
Chemical-resistive Cover
Battery
Silicon cover
NT20S-KBA01
C500-BAT08
0
Display history screens Order of occurrence (1,024 screens max.), order of frequency (255 times max.)
Graph
For alarm lists/histories
System startup
screen
Displayed when powering ON (or resetting ) the PT,
and when switching to RUN mode.
Options
For screen and system
data transfer
NT-MF161
Memory Unit
Numeral
settings
Programming
Console screen
Emulates PLC Programming Console functions,
capable of being called from RUN mode.
RS-232C/422A Adapter
Connector Kit
NS-AL002
Screen
attributes history
204.2 +0.5
Order of frequency, 256 screens
XM2S-0911-S003
0
Buzzer, display history, normal background colors,
backlight mode, local windows
Screen attributes
Max. number of
Ensures security: screens for which this attribute is set can
only be displayed if the correct password is input.
screen
Dimensions
3,999
Rear face
Menu
screen
178
Four items per screen
0:
1 to 3999: User registered screens
(normal, overlapping, windows)
System startup screen
No display
Screen types
Normal screen: Displays screen registered as normal.
250
100 122
53.5
9000:
9001:
9002:
9020:
Max. number of
registered screens
Screen number
Display history screens, order of occurrence
Display history screens, order of frequency
Programming Console screen
Transfer screen data created using an IBM PC/AT personal
computer to the PT.
Screen registration
method
4.5
39 min.
9999:
Return to previous screen designation
Screen saving
method
Saved to flash memory: 32 KB (downloading method)
By transferring screen data from the NT Support Tool
to the PT via serial communications
110
Screen registration
method
By mounting the Memory Unit and downloading
(automatic/manual transfer) data to the PT
Saving screen data
Flash memory (PT internal image memory)
15.5
28
142
190
Panel thickness: 1.6 to 4.8 mm
178.5 +0.5
19.5
x 100.5
0 mm (W x H)
52.5
6
Cat. No. V071-E1-02
2007.3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
相关型号:
©2020 ICPDF网 联系我们和版权申明