S8VK-R10 [OMRON]

Contribute to build high reliable systems Compact and Cost-effective solution for Back-up applications Easy setup for system reliability requirement;
S8VK-R10
型号: S8VK-R10
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Contribute to build high reliable systems Compact and Cost-effective solution for Back-up applications Easy setup for system reliability requirement

文件: 总12页 (文件大小:2363K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
New Product  
Redundancy Unit  
S8VK-R  
Contribute to build high reliable systems  
Compact and Cost-effective solution  
for Back-up applications  
Easy setup for system reliability  
requirement  
• Redundancy operating LED for the status confirmation  
• A signal output for failure detection of power supplies  
• By adjusting the power supply voltage to light up Balance LED,  
the lifetime of power supplies will be more than twice. *1  
• Wide range input  
DC5-30V (S8VK-R10), DC10-60V (S8VK-R20)  
• Wide operation temperature range: -40 to 70 °C  
• Safety standards:  
UL508/60950-1, CSA C22.2 No. 107.1/60950-1  
EN50178, EN60950-1 Lloyd's standards *2  
• EMS: EN61000-6-2  
EMI: EN61000-6-3  
5 year warranty *3  
Refer to Safety Precautions for All Power Supplies and Safety  
Precautions on page 9.  
!
*1. The lifetime will depend on the connected power supply.  
Refer to Functions on page 5.  
*2. Scheduled to obtain certification in September, 2013.  
*3. Five-year warranty conditions: Rated input voltage, 80% load, Ambient operating temperature: 40°C, Standard mounting.  
Model Number Structure  
Model Number Legend  
Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below.  
S8VK-R@@  
1
1. Output current  
10: 10 A  
20: 20 A  
Ordering Information  
Note: For details on normal stock models, contact your nearest OMRON representative.  
Input voltage  
DC5-30V  
DC10-60V  
Output current  
Model number  
S8VK-R10  
S8VK-R20  
10 A  
20 A  
1
S8VK-R  
Specifications  
Ratings, Characteristics, and Functions  
I t e m  
Output Current  
10 A  
20 A  
Voltage  
Current  
5 to 30 VDC  
2x 0 to 5 A  
1x 0 to 10 A  
10 A  
10 to 60 VDC  
2x 0 to 10 A  
1x 0 to 20 A  
20 A  
Input  
Continuous  
Output  
Current  
Power Boost 12 A (Refer to Engineering Data)  
24 A (Refer to Engineering Data)  
0.56 V typ. 2x5 A  
0.63 V typ. 1x10 A  
0.7 V max. (-40°C 1x10 A)  
0.67 V typ. 2x10 A  
0.78 V typ. 1x20 A  
0.9 V max. (-40°C 1x20 A)  
Voltage  
drop  
Input to Output  
6.5 W 2x5 A  
7.1 W 1x10 A  
0.8 W 0 A  
15.8 W 2x10 A  
18.0 W 1x20 A  
0.8 W 0 A  
Power  
losses  
Indicator  
Contact  
Indicator  
Lighting: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ. (color: green)  
Photo switch contact ON: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ.  
Contact Ratings: 30 VDC, 50 mA  
REDUNDANCY  
OK  
Additional  
functions  
BALANCE  
Lighting: Voltage difference between Vin1 and Vin2 is less than 50 mV typ. (color: green)  
Ambient operating temperature -40 to 70°C (Refer to Engineering Data)  
Storage temperature  
-40 to 85°C  
Ambient operating humidity  
0% to 95% (Storage humidity: 0% to 95%)  
Dielectric strength  
1.0 kVAC for 1 min. (between all inputs outputs and  
terminal)  
(detection current: 20 mA)  
0.5 kVAC for 1 min. (between all inputs outputs and Signal contact)  
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions  
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions  
150 m/s2, 3 times each in X, Y, and Z directions  
Vibration resistance  
Shock resistance  
Conducted  
Conforms to EN61204-3 EN55011 Class B and based on FCC Class B  
Emission  
Others  
EMI  
Radiated  
Emission  
Conforms to EN61204-3 EN55011 Class B  
Conforms to EN61000-6-2  
EMS  
UL Listed: UL508 (Listing)  
UL UR: UL60950-1 (Recognition)  
cUL: CSA C22.2 No.107.1  
cUR: CSA C22.2 No.60950-1  
EN: EN50178, EN60950-1  
Lloyd's standards *  
Approved Standards  
Degree of protection  
Weight  
IP20 by EN/IEC60529  
183 g  
462 g  
* Scheduled to obtain certification in September, 2013.  
2
S8VK-R  
Connections  
Block Diagrams  
+V  
+V  
fuse:  
R10 20A  
R20 40A  
IN 1  
IN 2  
+V  
Only R20.  
-V  
OUTPUT  
+V  
fuse:  
R10 20A  
R20 40A  
-V  
-V  
-V  
Detection  
circuit  
REDUNDANCY  
OK  
Frame landing  
Construction and Nomenclature  
Nomenclature  
10 A Models  
20 A Models  
S8VK-R10  
S8VK-R20  
1
2
3
2
1
3
5
6
5
6
7
7
4
4
No.  
1
2
Name  
Function  
Input terminal 1  
Input terminal 2  
Connect the input 1 lines to these terminals.  
Connect the input 2 lines to these terminals.  
Connect the ground line to these terminals.  
3
terminal  
4
5
6
7
Output terminal  
Status indicator (redundancy OK: Green)  
Status indicator (voltage balance: Green)  
Connect the load lines to these terminals.  
Lighting: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ.  
Lighting: Voltage difference between Vin1 and Vin2 is less than 50 mV typ.  
Status contact (redundancy OK: photo switch) Photo switch contact ON: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ.  
3
S8VK-R  
Engineering Data  
Derating Curve  
Power Boost Function  
This function is possible when used in combination with S8VK-G (All  
Models).  
120  
A
B
C
Power Boost is a function that can output the temporary repeated  
boost current larger than the rated current.  
However, it should meet the following four Boost current conditions.  
1. Time that the boost current flows: t1  
100  
80  
2. The maximum value of the boost current: lp  
3. The average output current: lave  
4. The time ratio of the boost current flow: Duty  
60  
40  
Note: Boost current conditions  
20  
0
t1 10 s  
Ip Rated boost current  
lave Rated current  
40 25 10  
0
10 20 30 40 50 60 70 80  
Ambient temperature (°C)  
t1  
t1 + t2  
× 100 [%] 30%  
Duty=  
[A]  
A: Standard mounting  
B: Standard mounting, when contact mounted with S8VK-G  
60°C and over: the derating is 2.5%/°C (when contact mounted  
with S8VK-G)  
Ip: Boost current  
Rated current  
C: Face-up mounting  
50°C and over: the derating is 1.25%/°C  
lave: Average current  
Mounting  
(B) Contact Mounting  
(A) Standard (Vertical) mounting  
t1  
t2  
Do not allow the boost current to continue for more than 10  
seconds.  
Also, do not let the duty cycle exceed the boost current conditions.  
These conditions may damage the Power supply.  
Ensure that the average current of one cycle of the boost current  
does not exceed the rated output current.  
This may damage the Power Supply.  
Lessen the load of the boost load current by adjusting the ambient  
temperature and the mounting direction.  
S8VK-R  
POWER SUPPLY  
(S8VK-G)  
(C) Face-up mounting  
Combinations with the S8VK-G  
Redundant unit model  
Redundancy Higher capasity  
Power supply  
model  
S8VK-G015@@  
S8VK-G030@@  
S8VK-G060@@  
S8VK-G12024  
S8VK-G24024  
S8VK-G24048  
S8VK-G48024  
S8VK-G48048  
S8VK-R10  
S8VK-R10  
S8VK-R20  
S8VK-R20  
4
S8VK-R  
Functions  
Functions  
Status  
Output  
Display  
Green  
Green  
Relay switch output: OFF  
(Normally ON)  
Redundancy  
Voltage Balance  
---  
Status Functions  
Functions  
Operation  
Redundancy OK signal and LED will turn ON and light up when the input voltage difference is 2.4 V typ or less.  
The signal and LED will detect the failure of a power supply on one side, or connecting errors of power supply  
voltage.  
Redundancy Status  
(Refer to Chart 1.)  
Balance LED will light up when the input voltage difference is 50 mV typ or less.  
By adjusting the input voltage to light up LED, output current of each power supply will be balanced.  
The lifetime as a power supply system will be more than twice comparing when there is only one power supply.  
Applicable models: S8VK-G03005, S8VK-G06012, S8VK-G12024, S8VK-G240@@, S8VK-G480@@  
By adjusting the input voltage to light up LED, the fluctuation of the output voltage will be less when one of the  
power supply breaks.  
Voltage Balance Status  
(Refer to Chart 1.)  
Chart 1: Operation Timing  
Vin+2.4  
Vin+1.2  
Vin+0.05  
Vin+0.05  
Vin-0.05  
Vin-2.4  
Vin  
Vin-0.05  
Vin-1.2  
Vin1 (UNIT: V)  
Vin+2.4  
Vin+1.2  
Vin+0.05  
Vin+0.05  
Vin-0.05  
Vin-1.2  
Vin  
Vin-0.05  
Vin-2.4  
Vin2 (UNIT: V)  
LED: Lighting  
Photo switch: ON  
REDUNDANCY OK  
LED: Lighting  
BALANCE  
Reference Value  
Value  
Reliability (MTBF)  
Definition  
S8VK-R10: 720,000 hrs.  
S8VK-R20: 680,000 hrs.  
MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device  
failures, and indicates reliability of devices.  
Therefore, it does not necessarily represent a life of the product.  
Life expectancy  
Definition  
10 yrs. Min.  
The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%.  
Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor.  
5
S8VK-R  
Dimensions  
S8VK-R10  
(Unit: mm)  
110  
106  
(1)  
5
3.6 dia. (Bit #1)  
34.9  
75.4  
90  
8.5  
5
5.7  
3.5  
4.7  
7.62  
(Sliding: 10 max.)  
32  
3.6 dia. (Bit #1)  
Rail Stopper  
S8VK-R20  
117.8  
112.2  
5.0 dia. (Bit #2)  
(1)  
(4)  
6.35  
104.6  
34.7  
125  
20.5  
5
6.35  
(10)  
4.7  
(Sliding: 7.5 max.)  
8.2  
40  
5.0 dia. (Bit #2)  
Rail Stopper  
6
S8VK-R  
DIN Rail (Order Separately)  
Note: All units are in millimeters unless otherwise indicated.  
Mounting Rail (Material: Aluminum)  
PFP-100N  
PFP-50N  
0.15  
7.3  
4.5  
0.3  
0.15  
27  
35  
15 25  
10  
25  
25  
25  
15(5) *  
1
10  
1,000 (500) *  
* Values in parentheses are for the PFP-50N.  
Mounting Rail (Material: Aluminum)  
PFP-100N2  
16  
4.5  
0.3  
35  
27 24  
29.2  
1.5  
15 25  
10  
25  
25  
25 15  
1
10  
1,000  
End Plate  
PFP-M  
10  
6.2  
1.8  
M4×8 pan-  
head screw  
1
35.5  
35.5  
50  
1.8  
11.5  
1.3  
4.8  
10  
M4 spring washer  
Note: If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from  
aluminum abrasion.  
7
S8VK-R  
Mounting Brackets  
Name  
Model  
S82Y-VS10F  
Front-mounting bracket (for S8VK-R10)  
Front-mounting bracket (for S8VK-R20)  
Side-mounting bracket (for S8VK-R10)  
Side-mounting bracket (for S8VK-R20)  
S82Y-VK10F  
S82Y-VS10S  
S82Y-VK10S  
Type  
Model  
Dimensions  
Appearance  
41  
4.5 dia. 0.1  
Front-mounting  
bracket  
(for S8VK-R10)  
S82Y-VS10F  
35 0.1  
7.3  
10  
40  
50  
t = 1.0  
0.1  
140  
Front-mounting  
bracket  
(for S8VK-R20)  
150  
S82Y-VK10F  
0.1  
25  
5.4  
0.1  
4.5 dia.  
38  
t = 2.0  
Left-side mounting Right-side mounting  
0.1  
4.5 dia.  
0.1  
60  
80  
Side-mounting  
bracket  
(for S8VK-R10)  
S82Y-VS10S  
0.1  
55  
13  
35  
64  
t = 2.0  
73  
0.1  
0.1  
15.5  
40  
49  
50  
Left-side mounting  
Right-side mounting  
0.1  
4.5 dia.  
Side-mounting  
bracket  
(for S8VK-R20)  
0.1  
140  
125  
S82Y-VK10S  
150  
t = 2.0  
8
S8VK-R  
Safety Precautions  
Warning Indications  
Precautions for Safe Use  
Indicates a potentially hazardous  
situation which, if not avoided, may  
result in minor or moderate injury or in  
property damage.  
Wiring  
CAUTION  
Minor fire may possibly occur. Ensure that input and output  
terminals are wired correctly.  
Increases in the temperature of internal parts resulting from  
heating of wiring materials may result in deterioration or damage to  
parts. Use wiring materials suitable to the current being used. The  
following wiring materials, torque and strip length are  
recommended to prevent heating and possible fires in wiring  
materials.  
Supplementary comments on what to  
do or avoid doing, to use the product  
safely.  
Precautions for  
Safe Use  
Supplementary comments on what to  
do or avoid doing, to prevent failure to  
operate, malfunction or undesirable  
effect on product performance.  
Precautions for  
Correct Use  
Recommend Wire Type  
Terminal  
Input  
Model  
AWG  
Solid wire  
Twisted wire  
2.5 mm2  
4 mm2  
Meaning of Product Safety Symbols  
S8VK-R10  
S8VK-R20  
S8VK-R10  
S8VK-R20  
AWG14 to 12 2.5 to 4 mm2  
AWG12 to 10 4 to 6 mm2  
AWG14 to 12 2.5 to 4 mm2  
AWG12 to 10 4 to 6 mm2  
2.5 mm2  
4 mm2  
Used to warn of the risk of minor injury caused by  
high temperatures.  
Output  
Status  
contact  
S8VK-R@@ AWG16  
1.5 mm2  
---  
All  
terminals  
Used for general mandatory action precautions  
for which there is no specified symbol.  
wires to be stripped: 8 mm  
On rare occasions there is a risk of internal element deterioration  
and damage if use is continued in a short-circuit or over-current  
state.  
Do not apply more than 75N force to the terminal block when  
tightening it.  
Use to indicate prohibition when there is a risk of  
minor injury from electrical shock or other source  
if the product is disassembled.  
Use within a range that does not exceed the output current rating.  
When a load short-circuit occurs, the short-circuit current of two  
power supply units flows. Use output wiring that can handle the  
short-circuit current of two units. If the wiring does not have  
sufficient current capacity, connect a fuse on the output side.  
Recommended fuse S8VK-R10: 15 A, S8VK-R20: 30 A Fast-  
acting type  
!CAUTION  
Risk of a mild burn on rare occasions. Do not touch  
the device unit while it is powered on or immediately  
after the power is turned off.  
If the current rating of the output terminal is exceeded on the S8VK-  
R20, always use multiple terminals simultaneously.  
Risk of damage to internal components. Do not use in a state that  
exceeds the rated current of the signal output.  
The ignition may accidentally be caused. Tighten  
terminal screws to a specified torque 4.43 to  
5.31 lb-in (0.5 to 0.6 N·m).  
Minor electric shock, fire, or Product failure may  
occasionally occur. Do not allow any pieces of metal  
or conductors or any clippings or cuttings resulting  
from installation work to enter the Product.  
Installation Environment  
Do not use the Redundancy Unit in locations subject to shocks or  
vibrations. In particular, install the Redundancy Unit as far away as  
possible from contactors or other devices that are a vibration  
source.  
Risk of product damage. Do not reverse the polarity  
of the device input terminals when wiring.  
Install the Redundancy Unit well away from any sources of strong,  
high-frequency noise and surge.  
Ambient Operating and Storage Environments  
Store the product with ambient temperature 40 to 85°C, and  
relative humidity 0 to 95%.  
Risk of internal component deterioration and  
damage. Do not connect an AC power supply.  
The internal parts may occasionally be deteriorated or broken. Do  
not use at a temperature that exceed the operating temperature  
range for the mounting type.  
Use the product where the relative humidity is 0 to 95%.  
Avoid places where the product is subjected to direct sunlight.  
Avoid places where the product is subjected to penetration of  
liquid, foreign substance, or corrosive gas.  
Minor electric shock, fire, or Product failure may  
occasionally occur. Do not disassemble, modify, or  
repair the Product or touch the interior of the  
Product.  
Avoid places subject to shock or vibration.A device such as a  
contact breaker may be a vibration source.  
Set the Redundancy Unit as far as possible from possible sources  
of shock or vibration.  
If the Redundancy Unit is used in an area with excessive electronic  
noise or surge, be sure to separate the Redundancy Unit as far as  
possible from the noise sources.  
9
S8VK-R  
Precautions for Correct Use  
Mounting  
Dielectric Strength Test  
The long-term reliability of the S8VK-R can be increased by installing  
it properly and sufficiently considering heat dissipation.  
Install the S8VK-R so that the air flow circulates around it, because  
the S8VK-R is designed to radiate heat by means of natural air  
circulation.  
The S8VK-R is designed to withstand a voltage test of 1 kV AC  
between all input/output terminals and the chassis, and 0.5 kV AC  
between all input/output terminals and the signal output terminal, for  
one minute.  
Note:  
Can be used in a contact mounting with the S8VK-G (not covered by  
safety certification). Two S8VK-G units cannot be mounted together  
in a contact mounting.  
1. The S8VK-R may possibly be damaged from the impulse voltage  
if a testing device switch is used to abruptly apply or shut off 1 kV  
AC, 0.5 kV AC. Increase the applied voltage gradually using the  
voltage adjustment on the testing device.  
2. When testing, always short-circuit all terminals to prevent damage  
*4  
*4  
*1  
*2  
to the output terminal.  
Signal output  
Photo switch output  
Photo switch ON when input voltage difference is 2.4 V typ. or less.  
30 VDC max. (LVLC), 50 mA max., residual voltage when ON: 2 V  
max., leakage current when OFF: 0.1 mA max.  
*1. Convection of air  
*2. 75 mm min.  
*3. 75 mm min.  
*4. 20 mm min.  
Status display LEDs  
The status display LEDs show the status of the input power as shown  
in the table below.  
*3  
*1  
Redundancy OK  
Green on: Input voltage difference is 2.4 V typ. or less.  
Voltage balance  
Input Voltage  
Rating  
Green on: Input voltage difference is 50 mV typ. or less.  
The redundancy OK display/signal operates when the voltage  
difference is no more than 2.4 V typ. When using a 5 V or 12 V power  
supply, verify that there is no difference in the output voltages of the  
power supplies.  
The voltage balance display does not guarantee current balance. The  
degree of balance varies by model, and therefore if you require  
operation with balanced current, check the output current of each  
power supply unit.  
S8VK-R10: DC5 to 30V  
S8VK-R20: DC10 to 60V  
Input Power Supply Selection  
This product contains an internal fuse. If a power supply other than  
the S8VK-G is used, the fuse may blow, depending on the state of the  
load. Do not connect a power supply other than the S8VK-G to this  
product.  
The models below use a voltage balance display, and cannot be used  
as a current balance.  
S8VK-G015@@  
If you are building a redundant system, never use in a state that  
exceeds the rated current of the power supply. If one of the power  
supplies goes down, there is a risk that the voltage on the load side  
cannot be attained.  
Use the same model for the power supplies that are connected.  
On rare occasions internal element deterioration and damage may  
occur if use is continued in a short-circuit or over-current state. Do not  
continue use for more than 10 seconds.  
S8VK-G03012·S8VK-G03024  
S8VK-G06024  
When adjusting the voltage based on the voltage balance, adjust the  
voltage of only one power supply. If you must adjust the voltages of  
both power supplies, be sure to check the output voltage before use.  
If you want to use the voltage balance display to ensure that the  
expected life is obtained, use the same thickness and length of wiring  
from each S8VK-G to the S8VK-R.  
Do not use in applications where load rush current or overload may  
frequently occur. Slight risk of deterioration and damage due to  
internal loss.  
The signal output / status LED may occasionally not operate stably.  
When using in environments where the temperature is less than  
25 °C, always adjust the 5 V power supply to 5.3 V or higher.  
Connections  
It is possible to connect S8VK-R like below.  
REDUNDANCY  
MONITOR  
IN1 IN2  
FG  
OPTIONAL  
REDUNDANCY  
UNIT  
POWER SUPPLY  
POWER SUPPLY  
OUT  
L
N
L N  
LOAD  
L
N
10  
Terms and Conditions of Sale  
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed  
part of all quotes, agreements, purchase orders, acknowledgments, price lists,  
catalogs, manuals, brochures and other documents, whether electronic or in  
writing, relating to the sale of products or services (collectively, the "Products")  
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron  
objects to any terms or conditions proposed in Buyer’s purchase order or other  
documents which are inconsistent with, or in addition to, these Terms.  
2. Prices; Payment Terms. All prices stated are current, subject to change with-  
out notice by Omron. Omron reserves the right to increase or decrease prices  
on any unshipped portions of outstanding orders. Payments for Products are  
due net 30 days unless otherwise stated in the invoice.  
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.  
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR  
INTENDED USE. Omron further disclaims all warranties and responsibility of  
any type for claims or expenses based on infringement by the Products or oth-  
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-  
gation hereunder shall be, at Omron’s election, to (i) replace (in the form  
originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying  
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of  
the non-complying Product; provided that in no event shall Omron be responsi-  
ble for warranty, repair, indemnity or any other claims or expenses regarding  
the Products unless Omron’s analysis confirms that the Products were prop-  
erly handled, stored, installed and maintained and not subject to contamina-  
tion, abuse, misuse or inappropriate modification. Return of any Products by  
Buyer must be approved in writing by Omron before shipment. Omron Compa-  
nies shall not be liable for the suitability or unsuitability or the results from the  
use of Products in combination with any electrical or electronic components,  
circuits, system assemblies or any other materials or substances or environ-  
ments. Any advice, recommendations or information given orally or in writing,  
are not to be construed as an amendment or addition to the above warranty.  
See http://www.omron247.com or contact your Omron representative for pub-  
lished information.  
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices  
sent to Buyer after deducting transportation charges, taxes and duties, and will  
be allowed only if (i) the invoice is paid according to Omron’s payment terms  
and (ii) Buyer has no past due amounts.  
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or  
the maximum legal rate, whichever is less, on any balance not paid within the  
stated terms.  
5. Orders. Omron will accept no order less than $200 net billing.  
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all  
costs involved in, obtaining any government approvals required for the impor-  
tation or sale of the Products.  
7. Taxes. All taxes, duties and other governmental charges (other than general  
real property and income taxes), including any interest or penalties thereon, 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE  
imposed directly or indirectly on Omron or required to be collected directly or  
indirectly by Omron for the manufacture, production, sale, delivery, importa-  
tion, consumption or use of the Products sold hereunder (including customs  
duties and sales, excise, use, turnover and license taxes) shall be charged to  
and remitted by Buyer to Omron.  
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY  
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS  
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual  
price of the Product on which liability is asserted.  
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory  
to Omron, Omron reserves the right to stop shipments or require satisfactory 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and  
security or payment in advance. If Buyer fails to make payment or otherwise  
comply with these Terms or any related agreement, Omron may (without liabil-  
ity and in addition to other remedies) cancel any unshipped portion of Prod-  
ucts sold hereunder and stop any Products in transit until Buyer pays all  
amounts, including amounts payable hereunder, whether or not then due,  
which are owing to it by Buyer. Buyer shall in any event remain liable for all  
unpaid accounts.  
their employees from and against all liabilities, losses, claims, costs and  
expenses (including attorney's fees and expenses) related to any claim, inves-  
tigation, litigation or proceeding (whether or not Omron is a party) which arises  
or is alleged to arise from Buyer's acts or omissions under these Terms or in  
any way with respect to the Products. Without limiting the foregoing, Buyer (at  
its own expense) shall indemnify and hold harmless Omron and defend or set-  
tle any action brought against such Companies to the extent based on a claim  
that any Product made to Buyer specifications infringed intellectual property  
rights of another party.  
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation  
unless Buyer indemnifies Omron against all related costs or expenses.  
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-  
resulting from causes beyond its control, including earthquakes, fires, floods,  
strikes or other labor disputes, shortage of labor or materials, accidents to  
machinery, acts of sabotage, riots, delay in or lack of transportation or the  
requirements of any government authority.  
sive property of Omron Companies and Buyer shall not attempt to duplicate it  
in any way without the written permission of Omron. Notwithstanding any  
charges to Buyer for engineering or tooling, all engineering and tooling shall  
remain the exclusive property of Omron. All information and materials supplied  
by Omron to Buyer relating to the Products are confidential and proprietary,  
and Buyer shall limit distribution thereof to its trusted employees and strictly  
prevent disclosure to any third party.  
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:  
a.Shipments shall be by a carrier selected by Omron; Omron will not drop ship  
except in “break down” situations.  
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall 17. Export Controls. Buyer shall comply with all applicable laws, regulations and  
constitute delivery to Buyer;  
licenses regarding (i) export of products or information; (iii) sale of products to  
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of  
regulated technology or information.  
c. All sales and shipments of Products shall be FOB shipping point (unless oth-  
erwise stated in writing by Omron), at which point title and risk of loss shall  
pass from Omron to Buyer; provided that Omron shall retain a security inter- 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right  
est in the Products until the full purchase price is paid;  
d.Delivery and shipping dates are estimates only; and  
e.Omron will package Products as it deems proper for protection against nor-  
mal handling and extra charges apply to special conditions.  
and no course of dealing between Buyer and Omron shall operate as a waiver  
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder  
without Omron's written consent. (c) Law. These Terms are governed by the  
law of the jurisdiction of the home office of the Omron company from which  
Buyer is purchasing the Products (without regard to conflict of law princi-  
ples). (d) Amendment. These Terms constitute the entire agreement between  
Buyer and Omron relating to the Products, and no provision may be changed  
or waived unless in writing signed by the parties. (e) Severability. If any provi-  
sion hereof is rendered ineffective or invalid, such provision shall not invalidate  
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts  
against the amount owing in respect of this invoice. (g) Definitions. As used  
herein, “including” means “including without limitation”; and “Omron Compa-  
nies” (or similar words) mean Omron Corporation and any direct or indirect  
subsidiary or affiliate thereof.  
12. Claims. Any claim by Buyer against Omron for shortage or damage to the  
Products occurring before delivery to the carrier must be presented in writing  
to Omron within 30 days of receipt of shipment and include the original trans-  
portation bill signed by the carrier noting that the carrier received the Products  
from Omron in the condition claimed.  
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the  
Products will be free from defects in materials and workmanship for a period of  
twelve months from the date of sale by Omron (or such other period expressed  
in writing by Omron). Omron disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,  
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-  
Certain Precautions on Specifications and Use  
1. Suitability of Use. Omron Companies shall not be responsible for conformity  
with any standards, codes or regulations which apply to the combination of the  
Product in the Buyer’s application or use of the Product. At Buyer’s request,  
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-  
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Omron will provide applicable third party certification documents identifying 2. Programmable Products. Omron Companies shall not be responsible for the  
ratings and limitations of use which apply to the Product. This information by  
itself is not sufficient for a complete determination of the suitability of the Prod- 3. Performance Data. Data presented in Omron Company websites, catalogs  
user’s programming of a programmable Product, or any consequence thereof.  
uct in combination with the end product, machine, system, or other application  
or use. Buyer shall be solely responsible for determining appropriateness of  
the particular Product with respect to Buyer’s application, product or system.  
Buyer shall take application responsibility in all cases but the following is a  
non-exhaustive list of applications for which particular attention must be given:  
and other materials is provided as a guide for the user in determining suitabil-  
ity and does not constitute a warranty. It may represent the result of Omron’s  
test conditions, and the user must correlate it to actual application require-  
ments. Actual performance is subject to the Omron’s Warranty and Limitations  
of Liability.  
(i) Outdoor use, uses involving potential chemical contamination or electrical 4. Change in Specifications. Product specifications and accessories may be  
interference, or conditions or uses not described in this document.  
(ii) Use in consumer products or any use in significant quantities.  
(iii) Energy control systems, combustion systems, railroad systems, aviation  
systems, medical equipment, amusement machines, vehicles, safety equip-  
ment, and installations subject to separate industry or government regulations.  
(iv) Systems, machines and equipment that could present a risk to life or prop-  
erty. Please know and observe all prohibitions of use applicable to this Prod-  
uct.  
changed at any time based on improvements and other reasons. It is our prac-  
tice to change part numbers when published ratings or features are changed,  
or when significant construction changes are made. However, some specifica-  
tions of the Product may be changed without any notice. When in doubt, spe-  
cial part numbers may be assigned to fix or establish key specifications for  
your application. Please consult with your Omron’s representative at any time  
to confirm actual specifications of purchased Product.  
5. Errors and Omissions. Information presented by Omron Companies has been  
checked and is believed to be accurate; however, no responsibility is assumed  
for clerical, typographical or proofreading errors or omissions.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS  
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT  
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO  
OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS  
Schaumburg, IL USA 847.843.7900 800.556.6766 www.omron247.com  
OMRON CANADA, INC. • HEAD OFFICE  
Toronto, ON, Canada 416.286.6465 866.986.6766 www.omron247.com  
OMRON ARGENTINA • SALES OFFICE  
Cono Sur 54.11.4783.5300  
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE  
México DF 52.55.59.01.43.00 001.800.556.6766 mela@omron.com  
OMRON CHILE • SALES OFFICE  
Santiago 56.9.9917.3920  
OMRON ELECTRONICS DE MEXICO • SALES OFFICE  
Apodaca, N.L. 52.81.11.56.99.20 001.800.556.6766 mela@omron.com  
OTHER OMRON LATIN AMERICA SALES  
54.11.4783.5300  
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE  
São Paulo, SP, Brasil 55.11.2101.6300 www.omron.com.br  
OMRON EUROpE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands.  
Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu  
Tel: +31 (0) 23 568 13 00  
Cat. No. T059-E3-01 06/13  
Note: Specifications are subject to change.  
© 2013 Omron Electronics LLC  
Printed in U.S.A.  

相关型号:

S8VK-R20

Contribute to build high reliable systems Compact and Cost-effective solution for Back-up applications Easy setup for system reliability requirement
OMRON

S8VK-S24024

AC-DC Regulated Power Supply Module,
OMRON

S8VK-S48024

AC-DC Regulated Power Supply Module,
OMRON

S8VM

Switch Mode Power Supply
OMRON

S8VM-01505

Switch Mode Power Supply
OMRON

S8VM-01505C

Switch Mode Power Supply
OMRON

S8VM-01505CD

Switch Mode Power Supply
OMRON

S8VM-01505D

Switch Mode Power Supply
OMRON

S8VM-01512

Switch Mode Power Supply
OMRON

S8VM-01512C

Switch Mode Power Supply
OMRON

S8VM-01512CD

Switch Mode Power Supply
OMRON

S8VM-01512D

Switch Mode Power Supply
OMRON