SSnaSp Action Switch
Subminiature Snap Action Switch
• Economical, subminiature snap action switch offers long
service life (30 million operations minimum)
• All models are free from overtravel restrictions, permit easy
setting
• Wide switching capacity range from microvoltage/current
loads (1 mA at 5 VDC to high-capacity loads 10.1 A at 250
VAC)
• Standard operating force, low force or super-low force
models available
• RoHS Compliant
Ordering Information
PCB terminal
Soldered
terminal
Tab (#110)
terminal
Contact
Rating
Actuator
OF
Straight
SS-01-ED
Left-angled
Right-angled
0.1 A
Pin plunger
25 g
—
—
SS-01-E
SS-01-F
SS-01-ET
SS-01-FT
50 g
150 g
8 g
SS-01-FD
—
—
SS-01D
SS-01D1
SS-01D2
SS-01
SS-01T
Hinge lever
SS-01GL-ED
SS-01GL-FD
SS-01GLD
—
—
SS-01GL-E
SS-01GL-F
SS-01GL
SS-01GL-ET
SS-01GL-FT
SS-01GLT
16 g
50 g
8 g
—
—
SS-01GLD1
SS-01GLD2
Simulated roller
lever
SS-01GL13-ED
SS-01GL13-FD
SS-01GL13D
SS-01GL2-ED
SS-01GL2-FD
SS-01GL2D
SS-5-FD
—
—
SS-01GL13-E
SS-01GL13-F
SS-01GL13
SS-01GL2-E
SS-01GL2-F
SS-01GL2
SS-5-F
SS-01GL13-ET
SS-01GL13-FT
SS-01GL13T
SS-01GL2-ET
SS-01GL2-FT
SS-01GL2T
SS-5-FT
16 g
50 g
8 g
—
—
—
—
Hinged roller
lever
—
—
—
—
16 g
50 g
50 g
—
—
5 A
Pin plunger
Hinge lever
SS-5-FD1
SS-5-FD2
150 g
16 g
50 g
16 g
SS-5D
SS-5D1
SS-5GL-FD1
SS-5GLD1
—
SS-5D2
SS-5GL-FD2
SS-5GLD2
SS-5
SS-5T
SS-5GL-FD
SS-5GLD
SS-5GL-F
SS-5GL
SS-5GL-FT
SS-5GLT
Simulated roller
lever
SS-5GL13-FD
SS-5GL13-FD2
SS-5GL13-F
SS-5GL13-FT
50 g
16 g
50 g
SS-5GL13D
SS-5GL2-FD
SS-5GL2D
SS-5GL13D1
SS-5GL2-FD1
SS-5GL2D1
SS-5GL13D2
SS-5GL2-FD2
SS-5GL2D2
SS-5GL13
SS-5GL2-F
SS-5GL2
SS-5GL13T
SS-5GL2-FT
SS-5GL2T
Hinge roller
lever
10 A
Pin plunger
Hinge lever
150 g
50 g
50 g
SS-10D
SS-10GLD
SS-10GL13D
—
—
—
—
—
—
SS-10
SS-10T
SS-10GLT
SS-10GL13T
SS-10GL
SS-10GL13
Simulated roller
lever
Hinge roller
lever
50 g
SS-10GL2D
—
—
SS-10GL2
SS-10GL2T
Snap Action Switch SS
95
Model Number Legend
SS-
1 2 3 4 5
(see note)
3. Maximum Operating Force
5. Terminals
None: Solder terminals
1. Ratings
None: 150 gf
-F:
-E:
10:
5:
10.1 A at 125 VAC
5 A at 125 VAC
0.1 A at 30 VDC
T:
Quick-connect terminals (#110)
Straight PCB terminals
50 gf (0.1A and 5A versions)
25 gf (0.1A versions)
D:
01:
D1:
D2:
Left-angled PCB terminals
Right-angled PCB terminals
2. Actuator
None: Pin plunger
GL: Hinge lever
4. Contact Form
None: SPDT
Note: These OF values are for the pin plunger models.
-2:
-3:
SPST-NC
SPST-NO
Consult Omron regarding the following:
- SPST-NC and SPST-NO versions
- High temperature versions that are rated from -25°C to 120°C
- Left and Right angled PCB terminal versions
GL13: Simulated roller lever
GL2: Hinge roller lever
Specifications
■ Characteristics
Operating speed
0.1 mm to 1 m/second (pin plunger models)
Operating frequency
Mechanical: 400 operations per minute max.
Electrical: 30 operations per minute max.
Insulation resistance
Contact resistance
100 MΩ at 500 VDC
150 gf: SS-10, SS-5 models:
SS-01 models:
30 mΩ max.
50 mΩ max.
50 mΩ max.
100 mΩ max.
150 mΩ max.
50 gf:
SS-5 models:
SS-01 models
SS-01 models
25 gf:
Dielectric strength (See note 2)
1,000 VAC (600 VAC for SS-01), 50/60 Hz for 1 minute between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground and between each
terminal and noncurrent-carrying metal parts
Vibration resistance (see note 3)
Shock resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
150 gf:
Destruction: 1,000 m/s2 (approx. 100G) max.
Malfunction: 300 m/s2 (approx. 30G) max.
Destruction: 500 m/s2 (approx. 50G) max.
Malfunction: 200 m/s2 (approx. 20G) max.
50 gf and 25gf:
Degree of protection
IEC IP40
Class I
Degree of protection against
electric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Service life
175
-25° to 85°C (at 60% RH max.) with no icing
85% max. (for 5°C to 35°C)
Mechanical:
30 million operations min. at 60 operations per minute (SS-01, SS-5)
10 million operations min. at 60 operations per minute (SS-10)
Electrical:
200,000 operations min. at 30 operations per minute (SS-01, SS-5)
50,000 operations min. at 30 operations per minute (SS-10)
Weight
Approx. 1.6 g pin plunger type
Note: 1. Data shown are of initial value.
2. The dielectric strength values shown is measured using a separator between the switch and metal mounting plate.
3. For pin plunger models, the above value apply for use at the free position and total travel position. For the lever models, the values apply
at the total travel position.
96
Snap Action Switch SS
■ Ratings (reference values)
Switch series:
SS-10 and SS-5
Lamp load Inductive load
SS-01
Resistive load
NC NO
5 A (10.1A)
Motor load
Resistive Load
Contact form
125 VAC
250 VAC
8 VDC
NC
1.5 A
1 A
NO
NC
NO
NC
NO
NC
NO
0.7 A
0.5 A
3 A
2 A
2.5 A
1.5 A
1.3 A
0.8 A
0.1 A
- - -
3 A (10.1A)
5 A (10.1A)
5 A (10.1A)
4 A
2 A
2 A
5 A
4 A
3 A
3 A
0.1 A
0.1 A
0.1 A
- - -
14 VDC
4 A
3 A
30 VDC
2 A
3 A
125 VDC
250 VDC
0.4 A
0.05 A
0.03 A
0.4 A
0.2 A
0.05 A
0.03 A
0.2 A
- - -
Note: 1. Data in parentheses apply to the SS-10 models only.
2. The above current ratings are the values of the steady-state current.
3. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). The inductive load rating of the SS-10 is the
same as that of SS-5.
4. Lamp load has an inrush current of 10 times the steady-state current
5. Motor load has an inrush current of 6 times the steady-state current.
6. If the switch is used in a DC circuit and is subjected to inrush current or surge, connect a surge suppressor across the switch.
7. The electrical rating applies under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/minute
■ Approved Standards
■ Contact Specifications
UL Recognized (File No. E41515)
CSA Certified (File No. LR21642)
Item
Specification
Material
Gap (standard value)
Inrush current
SS-10
SS-5
SS-01
Rivet
Silver alloy
0.5 mm
NC: 20A max. NC: 20A max.
NO: 15A max. NO: 10A max.
Crossbar
Gold alloy
0.25 mm
Rated Voltage
125 VAC
SS-10
- - -
SS-5
5 A
SS-01
0.1 A
- - -
Silver
250 VAC
10.1 A
- - -
3 A
1A max.
30 VDC
- - -
0.1 A
Minimum applicable
load (see note)
160 mA at 5 VDC
1 mA at 5 VDC
EN61058-1 - - VDE approval
(File No. 129246 for SS-5, 125256 for SS-10)
Note: Minimum applicable loads are indicated by N standard refer-
ence values. This value represents the failure rate at a 60%
(λ60) reliability level (JIS C5003).
Rated Voltage
SS-10
SS-5
250 VAC
10.1 A
5 A
-6
The equation λ60=0.5 x 10 / operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
EN61058-1 - - TÜV Rheinland approval
(File No. J9451450)
Rated Voltage
SS-10
SS-5
250 VAC
10.1 A
5 A
Testing conditions: 5E4 (50,000 operations), T85 (0°C to 85°C)
Note: The rated values approved by each of the safety standards
(e.g. UL, CSA) may be different from the performance charac-
teristics individually defined in this catalog.
Snap Action Switch SS
97
Engineering Data
■ Mechanical Service Life
■ Electrical Service Life
SS-01, SS-5 Models
SS-5 Models
(Pin Plunger Models)
(Pin Plunger Models)
5,000
Ambient temperature: 20 2°C
Ambient humidity: 65 5%
Operating frequency: 30 operations/min
Ambient temperature: 20 2°C
Ambient humidity: 65 5%
Without load
3,000
40,000
cosφ = 1
Operating frequency: 60 operations/min
1,000
30,000
20,000
10,000
5,000
125 VAC
500
300
250 VAC
100
50
30
10
0
1
2
3
4
5
6
7
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Overtravel (mm)
Switching current (A)
■ Mounting
■ Contact Form
Panel Mounting
SPDT
SPST-NC
SPST-NO
All switches may be panel mounted using M2.3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.23 to 0.26 N·m.
Two, 2.4-dia. mounting holes or
M2.3 screw holes
COM
NO
NC
COM
NC
COM
NO
* Consult Omron for SPST-NC and SPST-NO contact form types
ordering information.
9.5 0.1
PCB Layout
Three, 1.35 to 1.5 dia.
(1.6)
+0.15
–0.05
8.8
16.1 0.1
98
Snap Action Switch SS
Dimensions
■ Terminals
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. Terminal plate thickness is 0.5 mm for all models.
Quick-connect Terminals (#110)
Solder Terminals
PCB Terminals
0.6
2.9
3.3
2.9
1.6
2.9
7.0
6.4
10.6
7.1
1.6
0.5
3.2
8.8
7.3
1.2
2.8
8.8
7.3
1.6
Three,
1.6-dia. holes
8.8
7.3
COM
terminal
(C)
9.5 0.1
COM
terminal
(C)
3.2
6.4
9.5 0.1
3.2
19.8
t = 0.5
9.5 0.1
19.8
Three, 1.2 dia.
19.8
NO terminal
COM terminal (C)
NC terminal
NO terminal
NC terminal
NO terminal
NC terminal
Note:Terminal plate thickness is 0.5 mm for all models.
PCB, Left-angled terminal
PCB, Right-angled terminal
Note: Angled terminal directions
are shown below.
Left-angled terminal
Right-angled terminal
COM
terminal
COM
terminal
NC
terminal
NC terminal
NO terminal
NO terminal
■ Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The following illustrations and dimensions are for solder terminal models.
Refer to “Terminals” for models with quick-connect terminals (#110) or PCB terminals.
3. The operating characteristics are for operation in the A direction(
)
Pin Plunger Models
7.5
PT
3.2
SS-01(-E, -F)
2
SS-5(-F)
SS-10
A
OP
9.5
10.2
2.9
2.5
6.4
6.4
2.5 0.07 dia.
1.6
3.2
6.4
e, 1.6 dia.
8.8
7.3
5.1 9.5 0.1
19.8
Characteristics
Part number
SS-01-E
25 g
2 g
0.5 mm
0.5 mm
0.1 mm
SS-01-F, SS-5-F
50 g
SS-01, SS-5
150 g
SS-10
150 g
25 g
0.6 mm
0.4 mm
0.12 mm
OF max.
RF min.
PT max.
OT min.
MD max.
OP
4 g
0.5 m
0.5 mm
0.1 mm
25 g
0.5 mm
0.5 mm
0.1 mm
8.4 0.5 mm
Snap Action Switch SS
99
Hinge Lever Models
SS-01GL(-E, -F)
SS-5GL(-F)
SS-10GL
A
14.5 (see note 2)
t = 0.3
3.6
FP
OP
9.5
10.2
2.5
2.9
6.4
2.5 0.07 dia.
1.6
e, 1.6 dia.
3.2
6.4
8.8
7.3
5.1 9.5 0.1
19.8
Note: 1. Stainless-steel lever
2. Besides the SS- GL models with a hinge lever length of 14.5, the SS- GL11 models with a hinge lever length of 18.5, the
SS- GL111 models with a hinge lever length of 22.6, and the SS- GL1111 models with a hinge lever length of 37.8 are available.
Contact your OMRON representative for these models
Characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
SS-01GL-E
8 g
1 g
1.2 mm
0.8 mm
SS-01GL-F, SS-5GL-F
SS-01GL, SS-5GL
SS-10GL
50 g
6 g
1.0 mm
1.0 mm
16 g
2 g
1.2 mm
0.8 mm
50 g
6 g
1.2 mm
0.8 mm
13.6 mm
8.8 0.8 mm
Simulated Roller Lever Models
SS-01GL13(-E, -F)
SS-5GL13(-F)
SS-10GL13
A
15.8
1.3R
3.6
t = 0.3
(see note)
FP
OP
10.2
9.5
2.5
2.9
6.4
ee, 1.6 dia.
2.5 0.07 dia.
1.6
3.2
6.4
8.8
7.3
5.1 9.5 0.1
Note: Stainless-steel spring lever
19.8
Characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
SS-10GL13-E
8 g
SS-10GL13-F, SS-5GL13-F
SS-01GL13, SS-5GL13
SS-10GL13
50 g
6 g
1.0 mm
1.0 mm
16 g
2 g
1.2 mm
0.8 mm
50 g
6 g
1.2 mm
0.8 mm
1 g
1.2 mm
0.8 mm
15.5 mm
10.7±0.8 mm
Hinge Roller Lever Models
SS-01GL2(-E, -F)
SS-5GL2(-F)
SS-10GL2
14.5
48 da. × 3.2
ote 2)
A
t = 0.3
(see note 1)
FP
OP
9.5
10.2
2.5
2.9
6.4
2.5 0.07 dia.
1.6
ee, 1.6 dia.
3.2
6.4
8.8
7.3
5.1 9.5 0.1
Note: 1. Stainless-steel spring lever
19.8
2. Polyacetal resin roller
Characteristics
OF max.
RF min.
OT min.
MD max.
FP max.
OP
SS-01GL2-E
8 g
1 g
1.2 mm
0.8 mm
SS-01GL2-F, SS-5GL2-F
SS-01GL2, SS-5GL2
SS-10GL2
16 g
2 g
1.2 m
0.8 mm
50 g
6 g
1.2 mm
0.8 mm
50 g
6 g
1.0 mm
1.0 mm
19.3 mm
14.5 0.8 mm
100
Snap Action Switch SS
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Correct Use
■ Cautions
Mounting
Handling
Mount the switch onto a flat surface. Mounting on an uneven surface
may cause deformation of the switch, resulting in faulty operation or
breakage in the housing.
Turn OFF the power supply before mounting or removing the switch,
wiring, or performing maintenance for inspection. Failure to do so
may result in electric shock or burning
Operating Stroke
Terminal Connection
Take particular care in setting the operating stroke for the pin plunger
models. Make sure that the operating stroke is 70% to 100% of the
rated OT distance. Do not operate the actuator exceeding the OT dis-
tance, otherwise the life expectancy of the switch may be shortened.
When soldering the lead wire to the terminal, first insert the lead wire
conductor through the terminal hole and then solder.
Make sure that the capacity of the soldering iron is 60 W maximum.
Do not take more than 5 seconds to solder the switch terminal.
Improper soldering involving an excessively high temperature or
excessive soldering time may deteriorate the characteristics of the
switch.
Using Microloads
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for
microloads and that operate in the following range;
Be sure to apply only the minimum required amount of flux. The
switch may have contact failures if flux intrudes in the interior of the
switch.
Use the following lead wires to connect to the solder terminals;
26mA 100mA
0.16mA
30
24
Model
SS-5
Conductor size
0.5 to 0.75 mm2
0.75 mm2
SS-10
If the PCB terminal models are soldered in a solder bath, flux will per-
meate inside the switch and cause contact failure. Therefore, manu-
ally solder the PCB terminal.
Wire the quick-connect terminals (#110) with receptacles. Insert the
terminals straight into the receptacles. Do not impose excessive
force on the terminal in the horizontal direction, otherwise the termi-
nal may be deformed or the housing may be damaged.
12
Inoperable
range
5
0
1mA
1
100mA
160mA
Insulation Distance
10
100
1,000
Use a separator between the switch and metal mounting panels, to
ensure proper dielectric characteristics are achieved.
Current (mA)
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, then contact wear may
increase and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
According to EN61058-1, the minimum insulation thickness for this
switch should be 1.1 mm and minimum clearance distance between
the terminal and mounting plate should be 1.6 mm. If the insulation
distance cannot be provided in the product incorporating the switch,
either use a switch with insulation barrier or use a separator to
ensure sufficient insulation distance.
Separator
Snap Action Switch SS
101
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
11/10
Specifications subject to change without notice
Printed in USA