V-166-1A5 [OMRON]

Snap Action Switch; 速动开关
V-166-1A5
型号: V-166-1A5
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Action Switch
速动开关

开关
文件: 总16页 (文件大小:1266K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Snap Action Switch  
V
General Purpose Snap Action Switch  
Industry standard design with switching currents of 10A to 21A  
• Widely used for applications where long life expectancy and  
high reliability is required.  
Choose from a variety of levers, terminals and operating forces.  
• Right and Left Barrier options are available for the V-21 and  
V-16 models  
• Heat resistant versions of the V-15 and V-10 are available.  
• RoHS Compliant  
Ordering Information  
Model Number Legend  
V -  
-
-
-
1 2 3 4 5 6 7  
8
9
1. Ratings  
7. Maximum Operating Force  
4. Contact Form  
21:  
16:  
15:  
11:  
10:  
21 A at 250 VAC  
6:  
5:  
4:  
400 gf  
200 gf  
100 gf  
COM Terminal, Bottom position:  
16 A at 250 VAC  
15 A at 250 VAC  
11 A at 250 VAC  
10 A at 250 VAC  
1:  
2:  
3:  
SPDT  
SPST-NC  
SPST-NO  
Note: These OF values are for  
the pin plunger models.  
COM Terminal, Side position:  
2. Contact Gap  
None: 1 mm (F gap)  
G: 0.5 mm (G gap)  
3. Actuator  
None: Pin plunger  
4:  
5:  
6:  
SPDT  
8. Special Purpose  
SPST-NC  
SPST-NO  
None: Standard  
T:  
Heat resistive  
(V-15 and V-10, only)  
5. Terminals  
9. Mounting Hole Size  
A:  
C2:  
C:  
Solder terminals  
Quick-connect terminal (#187)  
Quick-connect terminal (#250)  
1:  
2:  
3:  
4:  
5:  
6:  
Short hinge lever  
Hinge lever  
Long hinge lever  
Simulated roller lever  
Short hinge roller lever  
Hinge roller lever  
None: 3.1 mm  
K:  
2.9 mm  
6. Insulation Barrier  
None: Without Barrier  
R:  
L:  
Right-hand barrier  
Left-hand barrier  
(Barriers available for V-21 and V-16, only)  
Note: Consult Omron regarding nominclature combinations and part numbers  
not found in this datasheet.  
Snap Action Switch V  
121  
Available Combinations  
Thermoplastic case  
Thermosetting case  
Model  
Rated Current  
V-21  
21 A  
V-16  
16 A  
V-11  
11 A  
V-15  
15 A  
V-10  
10 A  
COM  
terminal  
position  
OF 400 gf  
400 gf  
200 gf  
100 gf  
400 gf  
200 gf  
200 gf  
100 gf  
Insulation  
Heat  
Barrier Resistance  
Terminal Symbol  
Bottom  
No  
Standard  
(80°C)  
Solder terminals (A)  
- - -  
- - -  
Quick-connect  
terminals (#187)(C2)  
Quick-connect  
terminals (#250)(C)  
Heat  
resistant  
(150°C)  
Solder terminals (A)  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
Quick-connect  
terminals (#187)(C2)  
Quick-connect  
terminals (#250)(C)  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
Yes  
Standard  
(80°C)  
Solder terminals (A)  
Quick-connect  
terminals (#187)(C2)  
Quick-connect  
terminals (#250)(C)  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
Side  
No  
Standard  
(80°C)  
Solder terminals (A)  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
Quick-connect  
terminals (#187)(C2)  
Quick-connect  
terminals (#250)(C)  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
- - -  
Note: 1. : Available model.  
Consult OMRON for specific models with standard approval.  
List of Models  
Thermoplastic Case  
21 A (OF: 400 gf)  
Without barrier  
Right-hand barrier Left-hand barrier  
Common  
terminal Contact  
position form  
Terminal style Actuator  
Bottom  
SPDT  
Quick-connect  
(#250) (C)  
V-21-1C6  
V-21-2C6  
V-21-3C6  
V-211-1C6  
V-21-1CR6  
V-21-2CR6  
V-21-3CR6  
V-211-1CR6  
V-21-1CL6  
V-21-2CL6  
V-21-3CL6  
V-211-1CL6  
SPST-NC  
SPST-NO  
SPDT  
Pin plunger  
Short hinge lever  
Hinge lever  
V-212-1C6  
V-213-1C6  
V-212-1CR6  
V-213-1CR6  
V-212-1C6  
V-213-1CL6  
Long hinge lever  
V-214-1C6  
V-215-1C6  
V-214-1CR6  
V-215-1CR6  
V-214-1CL6  
V-215-1CL6  
Simulated roller lever  
Short hinge roller lever  
V-216-1C6  
V-216-1CR6  
V-216-1CL6  
Hinge roller lever  
Note: 1. Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate  
location to obtain 2.9 mm mounting holes. Example: V-21G2-1C6-K  
2. Not all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.  
122  
Snap Action Switch V  
16 A (OF: 200 gf)  
Without barrier  
Right-hand barrier Left-hand barrier  
Common  
terminal Contact  
position form  
Terminal style Actuator  
Bottom  
SPDT  
A
C2  
C
V-16-1A5  
V-16-1C25  
V-16-1C5  
V-16-1AR5  
V-16-1C2R5  
- - -  
V-16-1AL5  
V-16-1C2L5  
- - -  
Pin plunger  
SPST-NC  
SPST-NO  
SPDT  
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
V-16-2A5  
V-16-2C25  
V-16-2C5  
V-16-3A5  
V-16-3C25  
V-16-3C5  
V-16-2AR5  
V-16-2C2R5  
- - -  
V-16-3AR5  
V-16-3C2R5  
- - -  
V-161-1AR5  
V-161-1C2R5  
- - -  
V-162-1AR5  
V-162-1C2R5  
- - -  
V-163-1AR5  
V-163-1C2R5  
- - -  
V-164-1AR5  
V-164-1C2R5  
- - -  
V-165-1AR5  
V-165-1C2R5  
- - -  
V-166-1AR5  
V-166-1C2R5  
- - -  
V-16-2AL5  
V-16-2C2L5  
- - -  
V-16-3AL5  
V-16-3C2L5  
- - -  
V-161-1AL5  
V-161-1C2L5  
- - -  
V-162-1AL5  
V-162-1C2L5  
- - -  
V-163-1AL5  
V-163-1C2L5  
- - -  
V-164-1AL5  
V-164-1C2L5  
- - -  
V-165-1AL5  
V-165-1C2L5  
- - -  
V-166-1AL5  
V-166-1C2L5  
- - -  
V-161-1A5  
V-161-1C25  
V-161-1C5  
V-162-1A5  
V-162-1C25  
V-162-1C5  
V-163-1A5  
V-163-1C25  
V-163-1C5  
V-164-1A5  
V-164-1C25  
V-164-1C5  
V-165-1A5  
V-165-1C25  
V-165-1C5  
V-166-1A5  
V-166-1C25  
V-166-1C5  
Short hinge lever  
Hinge lever  
Long hinge lever  
Simulated roller lever  
Short hinge roller lever  
Hinge roller lever  
11 A (OF: 100 gf)  
Without barrier  
Common  
terminal  
position  
Contact form  
SPDT  
Terminal style  
A
C2  
C
Actuator  
Bottom  
V-11-1A4  
V-11-1C24  
V-11-1C4  
Pin plunger  
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
A
C2  
C
V-111-1A4  
V-111-1C24  
V-111-1C4  
V-112-1A4  
V-112-1C24  
V-112-1C4  
V-113-1A4  
V-113-1C24  
V-113-1C4  
V-114-1A4  
V-114-1C24  
V-114-1C4  
V-115-1A4  
V-115-1C24  
V-115-1C4  
V-116-1A4  
V-116-1C24  
V-116-1C4  
Short hinge lever  
Hinge lever  
Long hinge lever  
Simulated roller lever  
Short hinge roller lever  
Hinge roller lever  
Note: 1. Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate  
location to obtain 2.9 mm mounting holes. Examples: 1) V-16G3-1C25-K 2) V-11G-1A4-K  
2. Not all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.  
Snap Action Switch V  
123  
Thermosetting Case  
Standard models - 15 A / 10 A  
Common Contact Terminal style  
Actuator  
15 A  
10 A  
terminal  
position  
form  
SPDT  
200 gf  
200 gf  
100 gf  
Bottom  
A
V-15G-1A5-K  
V-15G-1C25-K  
V-15G-1C5-K  
V-15G-2A5-K  
V-15G-2C25-K  
V-15G-3A5-K  
V-15G-3C25-K  
V-15G-3C5-K  
V-15G-4A5-K  
V-15G-5A5-K  
V-15G-6A5-K  
V-15G1-1A5-K  
V-15G1-1C25-K  
V-15G2-1A5-K  
V-15G2-1C25-K  
V-15G3-1A5-K  
V-15G3-1C25-K  
V-10G-1A5-K  
V-10G-1C25-K  
V-10G-2A5-K  
V-10G-2C25-K  
V-10G-3A5-K  
V-10G-3C25-K  
V-10G-4A5-K  
V-10G-5A5-K  
V-10G-6A5-K  
V-10G1-1A5-K  
V-10G1-1C25-K  
V-10G2-1A5-K  
V-10G2-1C25-K  
V-10G3-1A5-K  
V-10G3-1C25-K  
V-10G-1A4-K  
V-10G-1C24-K  
V-10G-2A4-K  
V-10G-2C24-K  
V-10G-3A4-K  
V-10G-3C24-K  
V-10G-4A4-K  
V-10G-5A4-K  
V-10G-6A4-K  
V-10G1-1A4-K  
V-10G1-1C24-K  
V-10G2-1A4-K  
V-10G2-1C24-K  
V-10G3-1A4-K  
V-10G3-1C24-K  
Pin plunger  
C2  
C
SPST-NC  
SPST-NO  
A
C2  
A
C2  
C
Side  
SPDT  
A
SPST-NC  
SPST-NO  
SPDT  
Bottom  
A
Short hinge lever  
Hinge lever  
C2  
A
C2  
A
Long hinge lever  
C2  
A
C2  
A
V-15G4-1A5-K  
V-15G4-1C25-K  
V-15G5-1A5-K  
V-15G5-1C25-K  
V-10G4-1A5-K  
V-10G4-1C25-K  
V-10G5-1A5-K  
V-10G5-1C25-K  
V-10G4-1A4-K  
V-10G4-1C24-K  
V-10G5-1A4-K  
V-10G5-1C24-K  
Simulated roller lever  
Short hinge roller lever  
C2  
A
C2  
V-15G6-1A5-K  
V-15G6-1C25-K  
V-10G6-1A5-K  
V-10G6-1A4-K  
V-10G6-1C24-K  
Hinge roller lever  
Note: 1. For SPST-NC and SPST-NO with levers consult Omron.  
2. Not all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.  
Heat Resistant Models (Up to 150°C) - 15 A / 10A  
Common  
terminal  
position  
Contact  
form  
Terminal style  
Actuator  
15 A  
10 A  
200 gf  
100 gf  
Bottom  
SPDT  
Solder Terminals  
(A)  
V-15-1A5-T  
V-10-1A4-T  
Pin plunger  
V-151-1A5-T  
V-152-1A5-T  
V-101-1A4-T  
V-102-1A4-T  
Short hinge lever  
Hinge lever  
V-153-1A5-T  
V-103-1A4-T  
Long hinge lever  
V-154-1A5-T  
V-155-1A5-T  
V-104-1A4-T  
V-105-1A4-T  
Simulated roller lever  
Short hinge roller lever  
V-156-1A5-T  
V-106-1A4-T  
Hinge roller lever  
Note: 1. Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate  
location to obtain 2.9 mm mounting holes. Add “C2” to the part number in the appropriate location to obtain versions with #187 quick-  
connect terminals. Example: 1) V-15G1-1C25-T-K  
2. Not all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.  
124  
Snap Action Switch V  
Specifications  
Ratings (reference values)  
Type  
Rated voltage  
Non-inductive load  
Resistive load Lamp load  
NC NO NC NO  
Inductive load  
Inductive load  
NC NO  
Motor load  
NC NO  
V-21  
250 VAC  
8 VDC  
21 A  
21 A  
14 A  
0.6 A  
0.3 A  
16 A  
16 A  
10 A  
0.6 A  
0.3 A  
15 A  
15 A  
10 A  
0.6 A  
0.3 A  
11 A  
11 A  
6 A  
3 A  
5 A  
5 A  
0.1 A  
0.05 A  
2 A  
4 A  
4 A  
0.1 A  
0.05 A  
2 A  
4 A  
4 A  
0.1 A  
0.05 A  
1.5 A  
3 A  
12 A  
12 A  
12 A  
0.6 A  
0.3 A  
10 A  
10 A  
10 A  
0.6 A  
0.3 A  
10 A  
10 A  
10 A  
0.6 A  
0.3 A  
6 A  
6 A  
6 A  
0.6 A  
0.3 A  
6 A  
6 A  
6 A  
0.6 A  
0.3 A  
4 A  
7 A  
5 A  
0.1 A  
0.05 A  
3 A  
6 A  
4 A  
0.1 A  
0.05 A  
3 A  
6 A  
4 A  
0.1 A  
0.05 A  
2 A  
3 A  
3 A  
0.1 A  
0.05 A  
2 A  
30 VDC  
125 VDC  
250 VDC  
250 VAC  
8 VDC  
30 VDC  
125 VDC  
250 VDC  
250 VAC  
8 VDC  
30 VDC  
125 VDC  
250 VDC  
250 VAC  
8 VDC  
30 VDC  
125 VDC  
250 VDC  
250 VAC  
8 VDC  
V-16  
V-15  
V-11  
V-10  
3 A  
0.6 A  
0.3 A  
10 A  
10 A  
6 A  
0.1 A  
0.05 A  
1.5 A  
3 A  
3 A  
0.1 A  
0.05 A  
3 A  
3 A  
0.1 A  
0.05 A  
30 VDC  
125 VDC  
250 VDC  
0.6 A  
0.3 A  
Note: 1. The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current  
values of models with a contact gap of 0.5 mm (gap G).  
2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).  
3. Lamp load has an inrush current of 10 times the steady-state current.  
4. Motor load has an inrush current of 6 times the steady-state current.  
5. The ratings values apply under the following test conditions: Ambient temperature: 20±2°C, Ambient humidity: 65±5%, Operating frequency: 30 operations/min  
Approved Standards  
UL1054 (File No. E41515)  
CSA C22.2 No.55 (File No. LR21642)  
Rated voltage  
125 VAC  
250 VAC  
V-21  
V-16  
V-15  
V-11  
V-10  
21 A, 1/2 HP  
16 A, 1/2 HP  
15 A, 1/2 HP  
11 A, 1/3 HP  
10 A, 1/3 HP  
125 VDC  
250 VDC  
0.6 A  
0.3 A  
EN 61058-1 (File No. 129608, VDE approval)  
EN 61058-1 (File No. T9451451, TÜV Rheinland approval)  
Rated voltage  
250 VAC  
V-21  
20 (4) A  
V-16  
16 (4) A  
V-11  
11 (3) A  
Rated voltage  
250 VAC  
V-15  
15 A  
V-10  
10 A  
250 VDC  
0.3 A  
Testing conditions: 5E4 (50,000 operations), T105 (0°C to 105°C)  
Testing conditions: 5E4 (50,000 operations), T85 (0°C to 85°C)  
Snap Action Switch V  
125  
Characteristics  
Operating speed  
0.1 mm to 1 m/s (plunger models)  
Operating frequency  
Mechanical: 600 operations/minute, max.  
Electrical: 30 operations/minute, max.  
Insulation resistance  
100 MΩ min. (at 500 VDC)  
Contact resistance  
15 mΩ max.  
Dielectric strength (see note 2)  
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity  
V-21, V-16 and V-11:  
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between  
each terminal and non-current-carrying metal parts  
V-15 and V-10:  
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between  
each terminal and non-current-carrying metal parts  
Vibration resistance (see note 3)  
Shock resistance (see note 3)  
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude  
Destruction: 1,000 m/s2 (approx. 100G) max.  
Malfunction:  
V-21/V-16/V-15:  
300 m/s2 (approx. 30G) max.  
V-11/V10:  
200 m/s2 (approx. 20G) max.  
Life expectancy  
Mechanical: 50,000,000 operations min. (60 operations/minute)  
Electrical: V-21/V-16/V-15:  
100,000 operations min. (30 operations/minute)  
(V-15 heat resistive: 20,000 operations min. (30 ops/minute))  
300,000 operations min. (30 operations/minute)  
V-11/V-10:  
(V-10 heat resistive: 50,000 operations min. (30 ops/minute))  
Degree of protection  
IEC IP40  
Degree of protection against electric shock Class I  
Proof tracking index (PTI)  
175  
Ambient operating temperature  
-25  
-25  
°
C to 80  
°
C (at 60% RH max.) with no icing  
C for heat resistive models (at 60% RH max.) with no icing.  
°C to 150  
°
Ambient operating humidity  
Weight  
85% max. (for 5°C to 35°C)  
Approx. 6.2 g (plunger models)  
Note: 1. Data shown are of initial value.  
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.  
3. For pin plunger models, the above values apply for use at both the free position and total travel position. For lever models, they apply at  
the total travel position.  
4. For testing conditions, contact your OMRON sales representative.  
Contact Specifications  
Item  
V-21  
V-16  
V-15  
V-11  
V-10  
Contact  
Specification  
Material  
Rivet  
Silver alloy  
Silver  
Gap  
(standard value)  
1 mm (F gap type) or 0.5 mm (G gap type)  
Inrush current  
NC  
NO  
50 A max.  
40 A max.  
36 A max.  
24 A max.  
Minimum applicable load  
160 mA at 5 VDC  
Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60% 60) reliability level  
-6  
(JIS C5003). The equation λ60=0.5 x 10 / operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability  
level of 60%  
126  
Snap Action Switch V  
Engineering Data  
Electrical service life  
(Pin plunger models)  
Mechanical service life  
(Pin plunger models)  
V-21/-16/-15/-10  
V-21/-16/-15  
V-11/-10  
Ambient temperature: 20 2°C  
Ambient humidity: 65 5%  
Without load  
Ambient temperature: 20 2°C  
5
5
Ambient humidity: 65 5%  
Operating frequency: 60 operations/min  
cosφ = 1, 250 VAC  
Operating frequency: 60 operations/min  
cosφ = 1, 250 VAC  
Operating frequency: 600 operations/min  
200  
2
1
2
V-10 (0.98 N {100 gf}),  
V-11  
100  
1
0.5  
50  
0.5  
V-21  
Full stroke  
V-10 (1.96 N  
{200 gf})  
V-15  
V-16  
0.3  
0.3  
V-15  
V-16  
V-10  
V-11  
OT rated value  
10  
0.1  
0.1  
V-21  
0.01  
0
0.5 1 2 3 4 5 6 7 8 9 10 11 12  
0
4
8
12  
16  
20  
24  
28  
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 (1.6) 1.8  
OT (mm)  
Switching current (A)  
Switching current (A)  
Contact Form  
Barrier direction (V-21 and V-16)  
Right-hand Barrier  
Left-hand Barrier  
Common  
terminal  
position  
Contact form  
SPDT  
SPST-NC*  
SPST-NO*  
Bottom type  
Side type  
Mounting Holes  
All switches may be panel mounted using M3 mounting screws with  
plane washers or spring washers to securely mount the switch.  
Tighten the screws to a torque of 0.39 to 0.59 N·m.  
*
The SPST-NC and SPST-NO contact form types listed in the  
ordering information tables are for Pin Plunger models only.  
For information concerning lever models consult Omron.  
Two, 3.1-dia. mounting holes or  
M3 screw holes  
10.3 0.1  
22.2 0.1  
Snap Action Switch V  
127  
Dimensions  
Terminals  
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions  
2. The following table is for the SPDT contact specifications. Two terminals will be available for SPST-NO or SPST-NC contact specifications.  
For terminal positions, refer to the above Contact Form  
3. Right-angle PCB terminal type is available with some models (not shown). Drawings will be provided if requested.  
D5: Pins at right angles, to the right  
D6: Pins at right angle, to the left  
Terminal type  
Solder Terminal  
(A)  
Quick-connect Terminal  
Quick-connect Terminal  
(#250) (C)  
(#187) (C2)  
COM  
bottom position  
(5.5)  
(6.5)  
(5.5)  
(6.5)  
(4.9)  
(7.7)  
3.2  
2.9  
2.9  
(10)  
(10)  
(12.0)  
t = 0.8  
Three, quick-connect  
terminals (#250)  
t = 0.5  
t = 0.5  
Three, quick-connect  
terminals (#187)  
Three, solder terminals  
COM  
side position  
(5.5)  
(5.5)  
(6.5)  
(4.9)  
(7.7)  
(6.5)  
2.4  
2.4  
3.6  
(10)  
(12.0)  
(10)  
Terminal  
dimensions  
6.35  
3.2 (see note)  
8.1  
6.35  
3.2  
3.95  
4.75 0.1  
4.75 0.1  
6.35 0.1  
2.4 dia. 1.6 dia.  
1.6-dia. terminal hole  
1.65-dia. terminal hole  
Note: Indicates the length to the  
center of the 1.6-dia. holes  
128  
Snap Action Switch V  
Dimensions and Operating Characteristics  
Thermoplastic Case Models  
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions  
2. The following illustrations and drawings are for quick-connect terminals (#250) (terminals C). V models also incorporate terminals A and C2,  
which are omitted from the following drawings. Refer to Terminals section for the dimensions of these terminals.  
3. The @ in the model number is for the terminal code.  
4. The illustrations for V-21, V-16 and V-11 show a hole size of 3.1 mm. V-21, V-16 and V-11 models with a suffix “K” have a hole size of 2.9 mm.  
5. The operating characteristics are for operation in the A direction (  
).  
Pin Plunger Models  
20.2 0.25  
A
+0.13  
–0.03 dia. holes  
(Without Barrier)  
3.1  
1.6  
4.2  
PT  
2.8  
0.6  
2.8  
V-21-1  
V-16-1  
V-11-1  
6
5
4
2.8  
2.8  
OP  
8.4  
10.3 0.1  
19.1  
15.9  
+0.13  
–0.03  
3.1  
3.4 0.15 dia.  
t=0.8  
10.3  
Characteristics V-21-1@6  
V-16-1@5  
200 gf  
Three, quick-connect  
terminals (#250)  
22.2 0.1  
27.8  
39.8 0.8  
(12.0)  
2.8  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
400 gf  
80 gf  
50 gf  
1.2 mm  
1.0 mm  
0.4 mm  
14.7 ± 0.4 mm  
20.2 0.25  
1.6  
(With Right-hand Barrier)  
A
+0.13  
3.1  
–0.03 dia. holes  
V-21-1 R6  
PT  
4.2  
2.8  
V-16-1 R5  
0.6  
2.8  
2.8  
2.8  
OP  
8.4  
19.1  
10.3 0.1  
15.9  
Characteristics V-11-1@4  
V-11-1@5  
200 gf  
21.9  
+0.13  
3.1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
100 gf  
20 gf  
–0.03  
50 gf  
0.6  
3.4 0.15 dia.  
t=0.8  
1.2 mm  
Three, quick-connect  
22.2 0.1  
27.8  
(12.0)  
10.3  
2.8  
terminals (#250)  
1.0 mm  
0.4 mm  
39.8 0.8  
40.2  
14.7 ± 0.4 mm  
(With Left-hand Barrier)  
20.2 0.25  
A
+0.13  
3.1  
–0.03 dia. holes  
V-21-1 L6  
V-16-1 L5  
1.6  
PT  
4.2  
2.8  
2.8  
2.8  
0.6  
2.8  
OP  
19.1  
8.4  
15.9  
10.3 0.1  
+0.13  
21.9  
3.1  
–0.03  
t=0.8  
3.4 0.15 dia.  
0.6  
Three, quick-connect  
terminals (#250)  
(12.0)  
22.2 0.1  
27.8  
2.8  
10.3  
39.8 0.8  
40.2  
Snap Action Switch V  
129  
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions  
2. The following illustrations and drawings are for quick-connect terminals (#250) (terminals C). V models also incorporate terminals A and C2,  
which are omitted from the following drawings. Refer to Terminals section for the dimensions of these terminals.  
3. The @ in the model number is for the terminal code.  
4. The illustrations for V-21, V-16 and V-11 show a hole size of 3.1 mm. V-21, V-16 and V-11 models with a suffix “K” have a hole size of 2.9 mm.  
5. The operating characteristics are for operation in the A direction (  
).  
Short Hinge Lever Models  
V-211-1  
V-161-1  
V-111-1  
6
5
4
22.1  
Characteristics V-211-1@6 V-161-1@5 V-111-1@4  
t = 0.5  
(see  
note)  
8.1  
+0.13  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
400 gf  
50 gf  
200 gf  
50 gf  
100 gf  
15 gf  
4.3  
A
PT  
3.1  
–0.03 dia. holes  
1.6  
2.8  
0.6  
2.8  
2.8  
1.6 mm  
OP  
8.4  
10.3 0.1  
19.1  
0.8 mm  
15.9  
0.6 mm  
+0.13  
–0.03  
3.1  
15.2 ± 0.5 mm  
3.4 0.15 dia.  
t=0.8  
10.3  
Three, quick-connect  
22.2 0.1  
27.8  
(12.0)  
2.8  
terminals (#250)  
39.8 0.8  
Note: Stainless-steel lever  
Hinge Lever Models  
V-212-1  
V-162-1  
V-112-1  
6
5
4
35.6 0.8  
Characteristics V-212-1@6 V-162-1@5 V-112-1@4  
8.1 1.6  
t = 0.5  
(see note)  
+0.13  
3.1  
PT  
–0.03 dia. holes  
2.8  
8.4  
A
4.3  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
250 gf  
25 gf  
125 gf  
14 gf  
60 gf  
6 gf  
0.6  
2.8  
2.8  
OP  
4.0 mm  
10.3 0.1  
15.9 19.1  
1.6 mm  
+0.13  
–0.03  
3.1  
1.5 mm  
3.4 0.15 dia.  
t=0.8  
15.2 ± 1.2 mm  
Three, quick-connect  
terminals (#250)  
10.3  
22.2 0.1  
(12.0)  
2.8  
27.8  
39.8 0.8  
Note: Stainless-steel lever  
Long Hinge Lever Models  
V-213-1  
V-163-1  
V-113-1  
6
5
4
59.4 0.8  
1.6  
Characteristics V-213-1@6 V-163-1@5 V-113-1@4  
PT  
A
+0.13  
3.1  
4.3  
t = 0.5 (see note)  
–0.03 dia. holes  
2.8  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
130 gf  
12 gf  
70 gf  
6 gf  
35 gf  
- - -  
0.6  
2.8  
2.8  
OP  
8.4  
9.0 mm  
10.3 0.1  
15.9  
19.1  
2.0 mm  
3.2 mm  
+0.13  
–0.03  
3.1  
2.8 mm  
t=0.8  
3.4 0.15 dia.  
15.2  
± 2.6 mm  
Three, quick-connect  
terminals (#250)  
+2.6  
10.3  
15.2  
mm  
3.2  
22.2 0.1  
27.8  
(12.0)  
2.8  
Note: Stainless-steel lever  
39.8 0.8  
130  
Snap Action Switch V  
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions  
2. The following illustrations and drawings are for quick-connect terminals (#250) (terminals C). V models also incorporate terminals A and C2,  
which are omitted from the following drawings. Refer to Terminals section for the dimensions of these terminals.  
3. The @ in the model number is for the terminal code.  
4. The illustrations for V-21, V-16 and V-11 show a hole size of 3.1 mm. V-21, V-16 and V-11 models with a suffix “K” have a hole size of 2.9 mm.  
5. The operating characteristics are for operation in the A direction (  
).  
Simulated Roller Lever Models  
V-214-1  
V-164-1  
V-114-1  
6
5
4
32.6 0.8  
Characteristics V-214-1@6 V-164-1@5 V-114-1@4  
3.5R  
8.1 1.6  
PT  
+0.13  
A
t = 0.5  
(see note)  
3.1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
250 gf  
25 gf  
125 gf  
14 gf  
60 gf  
6 gf  
–0.03 dia. holes  
4.3 2.8  
0.6  
4.0 mm  
2.8  
2.8  
8.4  
OP  
10.3 0.1  
1.6 mm  
15.9 19.1  
1.5 mm  
+0.13  
–0.03  
3.1  
18.7 ± 1.2 mm  
3.4 0.15 dia.  
t=0.8  
10.3  
Three, quick-connect  
terminals (#250)  
22.2 0.1  
(12.0)  
2.8  
27.8  
39.8 0.8  
Note: Stainless-steel lever  
Short Hinge Roller Lever Models  
V-215-1  
V-165-1  
V-115-1  
6
5
4
Characteristics V-215-1@6 V-165-1@5 V-115-1@4  
20.1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
480 gf  
240 gf  
50 gf  
120 gf  
15 gf  
t = 0.5  
A
5.1  
0.6  
PT  
(see  
8.1 1.6  
+0.13  
50 gf  
note 1)  
4.8 dia. × 4.8  
(see note 2)  
3.1  
–0.03 dia. holes  
1.6 mm  
2.8  
2.8  
0.8 mm  
OP  
8.4  
10.3 0.1  
15.9  
0.6 mm  
19.1  
20.7 ± 0.6 mm  
+0.13  
–0.03  
3.1  
3.4 0.15 dia.  
t=0.8  
10.3  
Three, quick-connect  
terminals (#250)  
22.2 0.1  
27.8  
(12.0)  
2.8  
39.8 0.8  
Note: 1. Stainless-steel lever  
2. Oilless polyacetar resin roller  
Hinge Roller Lever Models  
34.0 0.8  
V-216-1  
V-166-1  
V-116-1  
6
5
4
PT  
8.1 1.6  
A
Characteristics V-216-1@6 V-166-1@5 V-116-1@4  
5.1  
t = 0.5  
(see note 1)  
0.6  
+0.13  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
250 gf  
25 gf  
125 gf  
14 gf  
60 gf  
6 gf  
4.8 dia. × 4.8  
(see note 2)  
3.1  
–0.03 dia. holes  
2.8  
2.8  
OP  
4.0 mm  
8.4  
10.3 0.1  
19.1  
15.9  
1.6 mm  
+0.13  
–0.03  
3.1  
1.5 mm  
3.4 0.15 dia.  
20.7 ± 1.2 mm  
10.3  
t=0.8  
Three, quick-connect  
terminals (#250)  
22.2 0.1  
(12.0)  
2.8  
27.8  
39.8 0.8  
Note: 1. Stainless-steel lever  
2. Oilless polyacetar resin roller  
Snap Action Switch V  
131  
Thermosetting Case Models  
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions  
2. The following illustrations are for quick-connect terminals (#250) (terminals C). Refer to Terminals section for the dimensions of other terminals.  
3. The @ in the model number is for the terminal code.  
4. The illustrations show models with a suffix “K”, which have a hole size of 2.9 mm. Omit the “K” to obtain models with hole size = 3.1 mm.  
5. The operating characteristics are for operation in the A direction (  
).  
Pin Plunger Models  
20.2 0.25  
V-15G-1 5-K  
V-10G-1 5-K  
V-10G-1 4-K  
4.2 2.8  
V-15G-1@5-K  
V-10G-1@5-K  
PT  
Characteristics  
V-10G-1@4-K  
2.8  
+0.13  
A
2.9  
–0.03 dia. holes  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
200 gf  
50 gf  
100 gf  
20 gf  
2.8  
OP  
10.3 0.1  
15.9  
18.8  
1.2 mm  
+0.13  
3.1  
–0.03  
1.3 mm  
0.3 mm  
3.4 0.15 dia.  
10.3  
t=0.5  
Three, solder  
terminals  
22.2 0.1  
27.8  
2.8  
(10)  
14.7 ± 0.4 mm  
37.8 0.8  
Short Hinge Lever Models  
t = 0.5 (see note)  
22.1  
V-15G1-1 5-K  
V-10G1-1 5-K  
V-10G1-1 4-K  
4.3 2.8  
V-15G1-1@5-K  
PT  
A
+0.13  
Characteristics  
V-10G1-1@4-K  
2.9  
–0.03 dia. holes  
V-10G1-1@5-K  
200 gf  
8.1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
100 gf  
15 gf  
2.8  
OP  
50 gf  
10.3 0.1  
15.9  
18.8  
1.5 mm  
+0.13  
–0.03  
3.1  
1.0 mm  
0.5 mm  
3.4 0.15 dia.  
10.3  
t=0.5  
Three, solder terminals  
22.2 0.1  
27.8  
2.8  
15.2 ± 0.5 mm  
(10)  
37.8 0.8  
Note: Stainless-steel lever  
Hinge Lever Models  
t = 0.5 (see note)  
35.6 0.8  
V-15G2-1@5-K  
V-15G2-1 5-K  
Characteristics  
V-10G2-1@4-K  
+0.13  
V-10G2-1@5-K  
125 gf  
V-10G2-1 5-K  
V-10G2-1 4-K  
PT  
2.9  
4.3 2.8  
A
–0.03 dia. holes  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
60 gf  
6 gf  
8.1  
14 gf  
2.8  
OP  
3.3 mm  
10.3 0.1  
15.9  
18.8  
2.3 mm  
+0.13  
–0.03  
3.1  
0.8 mm  
3.4 0.15 dia.  
10.3  
15.2 ± 1.2 mm  
+2.6  
15.2  
mm  
t=0.5  
3.2  
Three, solder terminals  
22.2 0.1  
2.8  
27.8  
(10)  
Note: Stainless-steel lever  
37.8 0.8  
Long Hinge Lever Models  
t = 0.5 (see note)  
59.4 0.8  
V-15G3-1 5-K  
V-10G3-1 5-K  
V-10G3-1 4-K  
A
4.3  
+0.13  
2.9  
–0.03 dia. holes  
15.9 18.8  
t=0.5  
PT  
V-15G3-1@5-K  
V-10G3-1@5-K  
Characteristics  
V-10G3-1@4-K  
8.1  
2.8  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
70 gf  
6 gf  
35 gf  
- - - gf  
2.8  
OP  
10.3 0.1  
9.0 mm  
3.0 mm  
7.6 mm  
3.2 mm  
+0.13  
–0.03  
3.1  
2.8  
10.3  
3.4 0.15 dia.  
2.0 mm  
15.2 ± 2.6 mm  
22.2 0.1  
27.8  
37.8 0.8  
(10)  
Three, solder terminals  
Note: Stainless-steel lever  
132  
Snap Action Switch V  
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions  
2. The following illustrations are for quick-connect terminals (#250) (terminals C). Refer to Terminals section for the dimensions of other terminals.  
3. The @ in the model number is for the terminal code.  
4. The illustrations show models with a suffix “K”, which have a hole size of 2.9 mm. Omit the “K” to obtain models with hole size = 3.1 mm.  
5. The operating characteristics are for operation in the A direction (  
).  
Simulated Roller Lever Models  
3.5R  
V-15G4-1 5-K  
t = 0.5 (see note)  
V-15G4-1@5-K  
V-10G4-1@5-K  
V-10G4-1 5-K  
Characteristics  
V-10G4-1@4-K  
4.3  
A
+0.13  
V-10G4-1 4-K  
32.6 0.8  
PT  
2.9  
–0.03 dia. holes  
15.9 18.8  
t=0.5  
8.1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
125 gf  
14 gf  
60 gf  
6 gf  
2.8  
2.8  
OP  
10.3 0.1  
3.3 mm  
2.3 mm  
0.8 mm  
+0.13  
–0.03  
3.1  
2.8  
(10)  
10.3  
3.4 0.15 dia.  
18.7 ± 1.2 mm  
22.2 0.1  
27.8  
37.8 0.8  
Three, solder terminals  
Note: Stainless-steel lever  
Short Hinge Roller Lever Models  
4.8 dia. × 4.8 (see note 2)  
V-15G5-1 5-K  
t = 0.5 (see note 1)  
V-10G5-1 5-K  
V-10G5-1 4-K  
A
V-15G5-1@5-K  
5.1  
20.1  
+0.13  
PT  
Characteristics  
V-10G5-1@4-K  
2.9  
–0.03 dia. holes  
V-10G5-1@5-K  
240 gf  
8.1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
120 gf  
15 gf  
2.8  
OP  
50 gf  
10.3 0.1  
15.9 18.8  
1.5 mm  
1.0 mm  
0.5 mm  
+0.13  
–0.03  
3.1  
2.8  
(10)  
10.3  
3.4 0.15 dia.  
t=0.5  
20.7 ± 0.6 mm  
22.2 0.1  
27.8  
Three, solder terminals  
37.8 0.8  
Note: 1. Stainless-steel lever  
2. Oilless polyacetar resin roller  
Hinge Roller Lever Models  
4.8 dia. × 4.8 (see note 2)  
t = 0.5 (see note 1)  
V-15G6-1 5-K  
V-10G6-1 5-K  
V-10G6-1 4-K  
A
V-15G6-1@5-K  
5.1  
34.0 0.8  
+0.13  
PT  
Characteristics  
V-10G6-1@4-K  
2.9  
–0.03 dia. holes  
V-10G6-1@5-K  
125 gf  
8.1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
60 gf  
6 gf  
2.8  
OP  
14 gf  
10.3 0.1  
15.9 18.8  
3.3 mm  
+0.13  
–0.03  
2.3 mm  
0.8 mm  
3.1  
2.8  
(10)  
10.3  
3.4 0.15 dia.  
20.7 ± 1.6 mm  
t=0.5  
22.2 0.1  
27.8  
37.8 0.8  
Three, solder terminals  
Note: 1. Stainless-steel lever  
2. Oilless polyacetar resin roller  
Accessories  
Refer to the “V/VX/D3C Common Accessories” datasheet for information regarding VAL, VAM and VAV external actuators (sold separately).  
Snap Action Switch V  
133  
Precautions  
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,  
“Snap Action Switches, Technical Information” for correct use.  
Correct Use  
Cautions  
Terminal Connection  
Insulation Distance  
To solder the lead to the solder terminal, apply a soldering iron rated  
at 60 W max. quickly (within 5 seconds) with the actuator at the free  
position.  
According to EN61058-1, the minimum insulation thickness for this  
switch should be 1.1 mm and minimum clearance distance between  
the terminal and mounting plate should be 1.0 mm. If the insulation  
distance cannot be provided in the product incorporating the switch,  
either use a switch with insulation barrier or use a separator to  
ensure sufficient insulation distance.  
Note that applying a soldering iron for too long a time or using one  
that is rated at more than 60 W may degrade the switch characteris-  
tics.  
Use an appropriate mating connector for #187 or #250 quick connect  
terminals.  
Specifications Approved by TÜV Rheinland  
According to EN61058-1  
Appropriate Cable Size (mm2)  
Model  
V-10  
Solder terminal  
0.75, 1.25, 2.0  
1.25, 2.0  
V-15  
Operation  
Make sure that the operating body pushes the switch actuator with  
an adequate force when the switch is to be operated, and that it does  
not touch the actuator when the switch is released.  
Do not change the operating position by modifying the actuator.  
Do not use the switch in a application where the operating speed is  
extremely slow or the actuator is set in the midpoint between the free  
position and operating position.  
Install the pin plunger switch so that the operating force is applied in  
alignment with the stroke of the actuator. The switch should be set so  
that its stroke is in the range of 60 to 90% of the rated OT (minimum  
value) when the switch has been operated.  
134  
Snap Action Switch V  
(b) Use in consumer Products or any use in significant quantities.  
(c) Energy control systems, combustion systems, railroad systems, aviation systems,  
medical equipment, amusement machines, vehicles, safety equipment, and  
installations subject to separate industry or government regulations.  
(d) Systems, machines, and equipment that could present a risk to life or property.  
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING  
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE  
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE  
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED  
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY  
SELLER.  
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of  
a programmable Product.  
Omron Electronic Components, LLC  
Terms and Conditions of Sales  
I. GENERAL  
1. Definitions: The words used herein are defined as follows.  
(a) Terms:  
(b) Seller:  
(c) Buyer:  
These terms and conditions  
Omron Electronic Components LLC and its subsidiaries  
The buyer of Products, including any end user in section III through VI  
(d) Products: Products and/or services of Seller  
(e) Including: Including without limitation  
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,  
invoices, purchase orders and other documents, whether electronic or in writing, relating  
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's  
purchase order or other documents which are inconsistent with, or in addition to, these  
Terms.  
3. Distributor: Any distributor shall inform its customer of the contents after and including  
section III of these Terms.  
IV. WARRANTY AND LIMITATION  
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in  
materials and workmanship for a period of twelve months from the date of sale by Seller  
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY  
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE OF THE PRODUCTS.  
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form  
originally shipped with Buyer responsible for labor charges for removal or replacement  
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an  
amount equal to the purchase price of the Product; provided that there shall be no  
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were  
correctly handled, stored, installed and maintained and not subject to contamination,  
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be  
approved in writing by Seller before shipment.  
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR  
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF  
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED  
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,  
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL  
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF  
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.  
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its  
employees from and against all liabilities, losses, claims, costs and expenses (including  
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding  
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or  
omissions under these Terms or in any way with respect to the Products.  
II. SALES  
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.  
Buyer agrees to pay the price in effect at the time the purchase order is accepted by  
Seller. Payments for Products received are due net 30 days unless otherwise stated in  
the invoice. Buyer shall have no right to set off any amounts against the amount owing in  
respect of this invoice.  
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to  
Buyer after deducting transportation charges, taxes and duties, and will be allowed only  
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past  
due amounts owing to Seller.  
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum  
legal rate, whichever is less, on any balance not paid within the stated terms.  
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.  
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer  
shall make remittance to Seller at the then current exchange rate most favorable to  
Seller; provided that if remittance is not made when due, Buyer will convert the amount  
to U.S. dollars at the then current exchange rate most favorable to Seller available  
during the period between the due date and the date remittance is actually made.  
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining  
any government approvals regarding the importation or sale of the Products.  
7. Taxes: All taxes, duties and other governmental charges (other than general real  
property and income taxes), including any interest or penalties thereon, imposed directly  
or indirectly on Seller or required to be collected directly or indirectly by Seller for the  
manufacture, production, sale, delivery, importation, consumption or use of the Products  
sold hereunder (including customs duties and sales, excise, use, turnover and license  
taxes) shall be charged to and remitted by Buyer to Seller.  
V. INFORMATION; ETC.  
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive  
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way  
without the written permission of Seller. Buyer (at its own expense) shall indemnify and  
hold harmless Seller and defend or settle any action brought against Seller to the extent  
that it is based on a claim that any Product made to Buyer specifications infringed  
intellectual property rights of another party.  
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or  
tooling, all engineering and tooling shall remain the exclusive property of Seller. All  
information and materials supplied by Seller to Buyer relating to the Products are  
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted  
employees and strictly prevent disclosure to any third party.  
3. Performance Data: Performance data is provided as a guide in determining suitability  
and does not constitute a warranty. It may represent the result of Seller's test conditions,  
and the users must correlate it to actual application requirements.  
4. Change In Specifications: Product specifications and descriptions may be changed at  
any time based on improvements or other reasons. It is Seller’s practice to change part  
numbers when published ratings or features are changed, or when significant  
engineering changes are made. However, some specifications of the Product may be  
changed without any notice.  
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,  
Seller reserves the right to stop shipments or require satisfactory security or payment in  
advance. If Buyer fails to make payment or otherwise comply with these Terms or any  
related agreement, Seller may (without liability and in addition to other remedies) cancel  
any unshipped portion of Products sold hereunder and stop any Products in transit until  
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,  
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid  
accounts.  
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer  
indemnifies Seller fully against all costs or expenses arising in connection therewith.  
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from  
causes beyond its control, including earthquakes, fires, floods, strikes or other labor  
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,  
delay in or lack of transportation or the requirements of any government authority.  
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:  
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise  
stated in writing by Seller), at which point title to and all risk of loss of the Products  
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in  
the Products until the full purchase price is paid by Buyer;  
5. Errors And Omissions: The information on Seller’s website or in other documentation  
has been carefully checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses  
regarding (a) export of the Products or information provided by Seller; (b) sale of  
Products to forbidden or other proscribed persons or organizations; (c) disclosure to non-  
citizens of regulated technology or information.  
(b) Delivery and shipping dates are estimates only; and  
(c) Seller will package Products as it deems proper for protection against normal  
handling and extra charges apply to special conditions.  
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products  
occurring before delivery to the carrier or any claim related to pricing or other charges  
must be presented in detail in writing to Seller within 30 days of receipt of shipment.  
III. PRECAUTIONS  
VI. MISCELLANEOUS  
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY  
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE  
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING  
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE  
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC  
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)  
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.  
Buyer acknowledges that it alone has determined that the Products will meet their  
requirements of the intended use in all cases. Buyer must know and observe all  
prohibitions of use applicable to the Product/s.  
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing  
between Buyer and Seller shall operate as a waiver of rights by Seller.  
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.  
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).  
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any  
dispute hereunder.  
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller  
relating to the Products, and no provision may be changed or waived unless in writing  
signed by the parties.  
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall  
not invalidate any other provision.  
2. Use with Attention: The followings are some examples of applications for which  
particular attention must be given. This is not intended to be an exhaustive list of all  
possible use of any Product, nor to imply that any use listed may be suitable for any  
Product:  
(a) Outdoor use, use involving potential chemical contamination or electrical  
interference.  
Snap Action Switch V  
Certain Precautions on Specifications and Use  
1. Suitability for Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's pro-  
dards, codes or regulations which apply to the combination of the Product in  
gramming of a programmable product, or any consequence thereof.  
Buyer's application or use of the Product. At Buyer's request, Seller will pro- 3. Performance Data. Performance data given in this publication is provided as  
vide applicable third party certification documents identifying ratings and limi-  
tations of use which apply to the Product. This information by itself is not  
sufficient for a complete determination of the suitability of the Product in com-  
bination with the end product, machine, system, or other application or use.  
a guide for the user in determining suitability and does not constitute a war-  
ranty. It may represent the result of Seller's test conditions, and the users must  
correlate it to actual application requirements. Actual performance is subject to  
Seller's Warranty and Limitations of Liability.  
Buyer shall be solely responsible for determining appropriateness of the par- 4. Change in Specifications. Product specifications and accessories may be  
ticular Product with respect to Buyer's application, product or system. Buyer  
shall take application responsibility in all cases but the following is a non-  
exhaustive list of applications for which particular attention must be given:  
(i) Outdoor use, uses involving potential chemical contamination or electrical  
interference, or conditions or uses not described in this document.  
(ii) Energy control systems, combustion systems, railroad systems, aviation  
systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government  
regulations.  
(iii) Use in consumer products or any use in significant quantities.  
(iv) Systems, machines and equipment that could present a risk to life or  
property. Please know and observe all prohibitions of use applicable to this  
product.  
changed at any time based on improvements and other reasons. It is our prac-  
tice to change part numbers when published ratings or features are changed,  
or when significant construction changes are made. However, some specifica-  
tions of the Product may be changed without any notice. When in doubt, spe-  
cial part numbers may be assigned to fix or establish key specifications for  
your application. Please consult with your Seller representative at any time to  
confirm actual specifications of purchased Product.  
5. Errors and Omissions. The information in this publication has been carefully  
checked and is believed to be accurate; however, no responsibility is assumed  
for clerical, typographical or proofreading errors, or omissions.  
6. RoHS Compliance. Where indicated, our products currently comply, to the  
best of our knowledge as of the date of this publication, with the requirements  
of the European Union's Directive on the Restriction of certain Hazardous  
Substances ("RoHS"), although the requirements of RoHS do not take effect  
until July 2006. These requirements may be subject to change. Please consult  
our website for current information.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS  
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT  
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE  
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website  
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
11/09  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X303-E-1  
Snap Action Switch V  

相关型号:

V-166-1A5-K

Snap Acting/Limit Switch, SPDT, Momentary, 16A, 8VDC, 5.6mm, Solder Terminal, Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1A6

Miniature Basic Switch that Offers High Reliability and Security

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1AL5

Snap Action Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1AL5-K

暂无描述

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1AR5

Snap Action Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1AR5-K

Snap Acting/Limit Switch, SPDT, Momentary, 16A, 8VDC, 5.6mm, Solder Terminal, Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1C25

Snap Action Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1C25-K

Snap Acting/Limit Switch, SPDT, Momentary, 16A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1C26

Miniature Basic Switch that Offers High Reliability and Security

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1C2L5

Snap Action Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1C2L5-K

Snap Acting/Limit Switch, SPDT, Momentary, 16A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

V-166-1C2R5

Snap Action Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON