V600-D8KR04 [OMRON]
Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems;型号: | V600-D8KR04 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems |
文件: | 总34页 (文件大小:3229K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Electromagnetic Coupling RFID System
V600
Non-contact Data Communications System
• New compact, slim Controller with two input channels added to
the lineup.
• Superior environmental resistance.
• Heat-resistant Data Carrier available (150°C max.).
• Large memory capacity of 8 kbytes for Built-in-battery Data Car-
riers and 254 bytes for Battery-less Data Carriers.
• Built-in-battery Data Carriers have a battery life detecting func-
tion.
• Data of Battery-less Data Carriers with small memory capacity
can be overwritten 300,000 times at normal temperatures.
• Thin, compact, and low-cost Data Carriers are available.
• Transmission distance of 100 mm max.
• CE marking/FCC approvals.
Ordering Information
■ Data Carriers
Item
Model
Specifications/Design/Memory capacity
Large Memory
Capacity
Built-in-battery Data Car- V600-D8KR12
riers
Rectangular compact
65 × 40 × 15 mm
8 Kbytes
V600-D8KR13
Thin rectangular
86 × 54 × 10.3 mm
V600-D8KR04
Intermediate-range rectangular
86 × 54 × 20 mm
Battery-less Data Carri-
ers
Intermediate-range rectangular
86 × 54 × 20 mm
V600-D8KF04
Replaceable-batteryData V600-D2KR16
Carriers
Compact
65 × 40 × 5 mm
2 Kbytes
Small Memory
Capacity
Battery-less Data Carri- V600-D23P71
ers
Ultrathin card-type
86 × 54 × 1.5 mm
254 bytes
V600-D23P72
Thin half-size card-type
50 × 34 × 1.5 mm
V600-D23P66N
V600-D23P66SP
Rectangular
34 × 34 × 3.5 mm
Rectangular package with PFA
95 × 36.5 × 6.5 mm
V600-D23P61
V600-D23P53
V600-D23P54
V600-D23P55
Rectangular compact
32 × 24 × 6 mm
Round super-compact
8 dia. × 5 mm
Round compact
12 dia. × 6 mm
Round super-compact
8 dia. × 5 mm
Electromagnetic Coupling RFID System V600
1
■ R/W Heads
Item
Model
Specifications/Design
Rectangular type
V600-H07 (0.5 m)
V600-H07 (2 m)
V600-H07 (5 m)
V600-H07 (10 m)
Dimensions: 100 × 100 × 30 mm
0.5-m cable
2-m cable
5-m cable
10-m cable
V600-H11 (0.5 m)
V600-H11-R (0.5 m)
V600-H11 (2 m)
V600-H11 (5 m)
V600-H11 (10 m)
V600-H51 (0.5 m)
V600-H51 (2 m)
V600-H51 (5 m)
V600-H51 (10 m)
V600-H52 (0.5 m)
V600-H52 (2 m)
V600-H52 (5 m)
V600-H52 (10 m)
Dimensions: 53 × 40 × 23 mm
0.5-m cable
0.5-m cable
2-m cable
5-m cable
10-m cable
0.5-m cable
2-m cable
5-m cable
10-m cable
0.5-m cable
2-m cable
5-m cable
10-m cable
Cylinder type
Dimensions: 22 dia. × 80 mm
Dimensions: 22 dia. × 85 mm
Separate-amplifier Amplifier V600-HA51 (2 m)
73.8 × 22.6 × 36.5 mm, with 2-m cable
73.8 × 22.6 × 36.5 mm, with 5-m cable
73.8 × 22.6 × 36.5 mm, with 10-m cable
12 dia. × 35 mm deep, with 2-m cable
type
section
V600-HA51 (5 m)
V600-HA51 (10 m)
V600-HS51
Sensor
section
V600-HS61
30.5 × 18 × 10 mm, with a 2-m cable
■ ID Controllers
Item
Model
Specifications/Design
DC Power Supply
24 VDC
Two R/W Head channels
105 × 90 × 65 mm
Host RS-232C, RS-422,
and RS-485 interfaces
V600-CA5D02
V600-CD1D-V3
V600-CM1D
24 VDC
Single R/W Head connect-
able
115 × 68 × 80 mm
24-VDC, 5-VDC 2-system
RS-232C host interface
input
Single R/W Head connect-
able
Board type
POWER
1
2
3
4
IN
1
OUUT
5
DC Power Supply
V600-IDSC02
V600-IDSC04
2
3
24 VDC
RS-232C interface
Two R/W Heads connect-
able
MAOON
No.
X10
DC24VV
IINNPUT
TEST
ON
HEAD1
HEAD22
POWWER
1
2
3
4
INN
1
OUT
5
2
3
Four R/W Heads connect-
able
MAON
No..
MAON
No.
X10
X10
DC24V
INPUT
TEST
ON
TESTT
ON
HEAADD1
HEAADD1
HEAD2
HEAD2
2
Electromagnetic Coupling RFID System V600
■ Accessories (Order Separately)
Item
Model
Specifications/Design
Extension cable for
R/W Heads
V600-A45
V600-A44
V600-A40
V600-A41
V600-A42
V600-A56
V600-A55
V600-A50
V600-A51
V600-A52
V600-A81
Standard cable
3-m cable
5-m cable
10-m cable
20-m cable
30-m cable
3-m cable
5-m cable
10-m cable
20-m cable
30-m cable
Non-water-resistant connectors
Robotic cable
Non-water-resistant connectors
Holder
For the V600-D2KR16
*Mount with M3 flat countersunk head screws (at least two).
V600-A84
V600-A86
For the V600-D23P71/D23P72
Ultrasonic deposition can be used on the plastic container.
Attachment
For the V600-D23P66N
■ RS-232C Cables (Order
■ Connectors for ID Controllers
Separately)
(One Set per Unit)
Model
XW2Z-200S
XW2Z-500S
Cable length
Compatible ID Controllers
Model
Name
Compatible ID Controllers
2 m
5 m
XM2A-0901
Connector
Plug
V600-CD1D-V3
V600-CM1D
V600-CD1D-V3
V600-CM1D
XM2S-0911
Connector
Hood
MC1.5/5-STF-3.5 RS-422/
(made by Phoenix RS-485
V600-CA5D02
Contact)
communica-
tions
connector
Electromagnetic Coupling RFID System V600
3
Specifications
■ Battery-less Data Carriers with Small Memory Capacity
Shape Ultrathin
Card-type
Ultrathin Rectangular Chemical- Rectangular
Round
Super-
compact
Round
Compact
Round
Super-
compact
Half-size
Compact
resistant
Compact
Card-type
Model
V600-
D23P71
V600-
D23P72
V600-
D23P66N
V600-
D23P66SP
V600-
D23P61
V600-
D23P53
V600-
D23P54
V600-
D23P55
Item
Memory capacity
Memory type
254 bytes
EEPROM (non-volatile memory)
Transmission distance Refer to “Transmission Distance Specifications for Battery-less Data Carriers with Small Memory Capacity” on
page 10.
Data retention time
(after writing data)
10 years
10 years (−40 10 years
to 110°C)
1 year (−40 to
150°C)
10 years (−40
to 110°C)
1 year (−40 to
150°C)
Number of
overwrites
(per address)
(Refer to
separate
item for
Up to 0°C 800,000 times
Up to
400,000 times
300,000 times
100,000 times
25°C
Up to
60°C
ambient
Up to
temperature) 85°C
Transmission error
detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Ambient
temperature storage
For data −20 to 110°C
−40 to 150°C −40 to 110°C −40 to 85°C
(See note.)
−40 to 150°C
(See note.)
For
reading/
writing
−10 to 70°C
−20 to 85°C −20 to 70°C −25 to 70°C
−25 to 85°C
Storage temperature
−20 to 110°C
−40 to 150°C −40 to 110°C −40 to 85°C
(See note.)
−40 to 150°C
(See note.)
Ambient humidity
Operating: 35% to 95%
IEC 60529: IP67
Degree of protection
IEC 60529:
IP68
IEC 60529:
IP67
IEC 60529: IP67
IEC 60529:
IP67
10 to 2,000 Hz, 3.0-mm double amplitude, 300 m/s2 accel-
eration for 30 min each in 3 directions (90 min total)
10 to 2,000 Hz,
1.5-mm double
amplitude,
10 to 2,000 Hz,
1.5-mm double
amplitude,
Vibration resistance
(destruction)
10 to 2,000 Hz, 3.0-mm
double amplitude, 300 m/s2
acceleration for 30 min
each in 3 directions (90 min
total)
150 m/s2 accel-
eration 10
150 m/s2 accel-
eration 10
times each in 3
directions (15
min)
times each in 3
directions (15
min)
1,000 m/s2 3 times each in 3
directions (18 times total)
1,000 m/s2 3 times each in 3 directions (18 times total)
Shock resistance
(destruction)
500 m/s2 3
times each in 3
directions (18
times total)
500 m/s2
3
times each in 3
directions (18
times total)
Weight
Approx. 15 g Approx. 5 g Approx 6.5 g Approx. 19 g Approx. 5.8 g Approx. 0.4 g Approx. 1.0 g Approx. 0.6 g
Note: The 150°C heat resistance was confirmed by leaving the Unit at 150°C for 1,000 continuous hours, and by a thermal shock test consisting
of 1,000 −10°C/150°C cycles of 30 min each. No defect was found among the 22 test samples.
4
Electromagnetic Coupling RFID System V600
■ Data Carriers with Large Memory Capacity
Shape
Built-in-battery
Battery-less
Rectangular
Replaceable-battery
Rectangular
Compact
Rectangular Thin
Rectangular
Rectangular
Compact with
Replaceable Battery
Intermediate Range Intermediate Range
Model
V600-D8KR12
V600-D8KR13
V600-D8KR04 V600-D8KF04
V600-D2KR16
Item
Memory capacity
Memory type
8 KB
SRAM (volatile memory)
2 KB
FeRAM
SRAM
(nonvolatile memory) (volatile memory)
Transmission distance Refer to “Transmission Distance Specifications for Data Carriers with Large Memory Capacity (Built-in-battery/Battery-
less/Replaceable-battery)” on page 15
Battery life (See note
1.)
Refer to “Battery Life” on page 22
--- (See note 4.)
1,000 million
2 years (at 25°C)
(See note 2.)
Number of reads/writes Unlimited
Unlimited (Does not
affect battery life)
Transmission error
detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Ambient
temperature storage
For data −40 to 70°C
−15 to 70°C
0 to 50°C
For
−25 to 70°C
reading/
writing
Storage temperature
Ambient humidity
Storage humidity
−40 to 70°C
−15 to 70°C
35% to 85%
35% to 95%
35% to 95%
IEC 60529: IP67
Degree of protection
IEC 60529: IP50 (dust-
proof) (See note 3.)
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in
X, Y, and Z directions
Vibration resistance
(destruction)
10 to 150 Hz, 0.75-mm
single amplitude, 100-
m/s2 acceleration for
30 min each in X, Y,
and Z directions
1,000 m/s2 3 times each in X, Y, and Z directions (18 times total)
500 m/s2 3 times each 300 m/s2 3 times each
Shock resistance
(destruction)
in X, Y, and Z direc-
tions (18 times total)
in X, Y, and Z direc-
tions (18 times total)
Weight
Approx. 70 g
Approx. 160 g
Approx. 150 g
Approx. 15 g
Note: 1. A low battery detection function is built-in.
2. The battery life is applicable for batteries used at a temperature of 25°C. Refer to “Temperature and Battery Life” on page 22 for details
on the relationship between temperature and battery life. The lithium battery is commercially available (CR2016).
3. The Data Carrier is dustproof when the provided battery replacement cover seal is used.
4. Data holding time: 10 years
Electromagnetic Coupling RFID System V600
5
■ Read/Write (R/W) Heads with Built-in Amplifier
Model
V600-H07
V600-H11/H11-R
V600-H51
V600-H52
Item
Oscillation frequency
Ambient temperature
Storage temperature
Ambient humidity
530 kHz
−25 to 70°C
−40 to 85°C
35% to 95%
35% to 95%
−10 to 60°C
−25 to 75°C
Storage humidity
Insulation resistance
Dielectric strength
Degree of protection
50 MΩ min. (at 500 VDC) between cable terminals and case
1,000 VAC, 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
IEC 60529: IP67
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in X, Y, and Z directions
Vibration resistance
(destruction)
Destruction: 500 m/s2 3 times each in X, Y, and Z directions (18 times total)
Shock resistance
Cable length (See note 1.) Standard lengths of 0.5 m, 2 m, 5 m, and 10 m.
Wireless transmission
error detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Indicators
Weight
Power: green; transmission: orange
Approx. 1 kg
Approx. 650 g (with 10-m cable)
(with 10-m cable)
Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52.
2. The connectors are not water-resistant.
6
Electromagnetic Coupling RFID System V600
■ Read/Write (R/W) Heads with Separate Amplifier
Model
Sensor section
Amplifier section
V600-HA51
V600-HS51
V600-HS61
Item
Oscillation frequency
Ambient temperature
Storage temperature
Ambient humidity
530 kHz
---
−10 to 60°C
−25 to 75°C
35% to 95%
Insulation resistance
Dielectric strength
Degree of protection
50 MΩ min. (at 500 VDC) between cable terminals and case
1,000 VAC 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
IEC 60529: IP67
10 to 2,000 Hz, 1.5-mm single amplitude, 300 m/s2 accel-
eration with 2 sweeps of 15 min each in 3 directions
IEC 60529: IP66
Installed in panel
Vibration resistance
(destruction)
10 to 2,000 Hz, 1.5-mm single am-
plitude, 300-m/s2 acceleration with 2
sweeps of 11 min each in 3 direc-
tions
DIN Track installa- 10 to 500 Hz, 1.0-mm single ampli-
tude, 150-m/s2 acceleration with 3
sweeps of 11 min each in 3 direc-
tions
tion
1,000 m/s2 3 times each in 3 directions (18 times total) 500 m/s2 3 times each in 3 directions (18 times total)
Shock resistance
(destruction)
Cable length Sensor to
amplifier
2 m (fixed)
---
Amplifier to ---
Standard lengths of 2 m, 5 m, and 10 m (See note 1.)
controller
Wireless transmission
error detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Indicators
Weight
---
Power: green; transmission: orange
Approx. 650 g (with 10-m cable)
Approx. 70 g (with 2-m cable)
Note: 1. Extension cables are also available. The maximum cable length is 50 m for the V600-HA51. Extension cables are not available for the
V600-HS51/HS61.
2. The connectors are not water-resistant.
Electromagnetic Coupling RFID System V600
7
■ ID Controllers
Series
V600 Series
Model
V600-CA5D02
V600-CD1D-V3
V600-CM1D
Item
Host interface
RS-232C, RS-422, RS-485
2
RS-232C
1
Possible number of R/W
Heads
Power supply voltage
24 VDC
24 VDC
24 VDC, 5 VDC
Acceptablepowersupply 20.4 to 26.4 VDC
voltage
20.4 to 26.4 VDC
20.4 to 26.4 VDC
4.5 to 5.5 VDC
Power consumption
Insulation resistance
Dielectric strength
15 W max.
7.2 W max.
24 VDC: 7.2 W max.
5 VDC: 1.5 W max.
50 MΩ min. (at 500 VDC) between power terminals and case, between I/O terminals and case, or between the power
supply terminals and I/O terminals
1,000 VAC, 50/60 Hz for 1 min be-
tween the points listed above;
Leakage current: 10 mA max.
1,000 VAC, 50/60 Hz for 1 min between the points listed above;
Leakage current: 10 mA max.
Noise immunity
1,500-V (p-p) pulses of 100-ns to 1-µs pulse width with a 1-ns rise time
Vibration
Destruction --- 10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z direc-
resistance
tions
Malfunction 10 to 150 Hz, 0.2-mm double ampli- 10 to 150 Hz, 0.2-mm double amplitude for 32 min each in X, Y, and Z direc-
tude, 15 m/s2 acceleration 10 times for
8 min each in 3 directions
tions
Destruction: 200 m/s2 3 times each in X, Y, and Z directions (18 times total)
---
Shock
resistance
Destruction ---
150 m/s2 3 times each in X, Y, and Z
directions (18 times total)
Malfunction
Ambient temperature
Ambient humidity
Operating conditions
Storage temperature
Memory back-up
−10 to 55°C
0 to 50°C
35% to 85% (with no condensation)
No corrosive gases
−25 to 65°C
−15 to 70°C
A capacitor backs up the most recent Memory backup is not available. Error details, however, can be read from the
error data and statistical error data for personal computer when the power is turned ON.
up to 20 days (at 25°C) after a power
interruption.
Diagnostic functions
Ground
Checks for CPU errors, memory errors, power interruptions, and transmission errors
Ground to 100 Ω or less.
Degree of protection
Weight
IEC 60529: IP30 (panel mounted)
Approx. 300 g
Approx 360 g
Approx. 180 g
8
Electromagnetic Coupling RFID System V600
■ V600-IDSC
Series
Model
V600-IDSC Series
V600-IDSC02
V600-IDSC04
POWER
POWER
1
1
IN
2
3
4
INN
2
3
4
1
OUT
5
1
2
3
OUT
5
2
3
MAON
No..
X10
MAON
No.
MAOON
No..
X10
X110
DC244VV
IINNPUT
DC244VV
IINNPUT
TESST
ON
TEST
ON
TEST
ON
HEAAD1
HEAD1
HEAD1
1
Item
HEAD2
HEAD2
HEAD2
2
Host interface
RS-232C
2
Possible number of R/W Heads
Power supply voltage
4
24 VDC
Acceptable power supply voltage
Power consumption
19.2 to 28.8 VDC
50 W max.
Insulation resistance
20 MΩ min. (at 500 VDC) between power supply terminals and frame ground terminals
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between power supply terminals and frame ground terminals with a de-
tected current of10 mA max.
10 to 50 Hz, 0.075-mm amplitude, 57 to 150 Hz, 9.8 m/s2 acceleration for 10 sweeps each in X, Y, and Z
directions
Vibration resistance
147 m/s2 3 times each in X, Y, and Z directions
Shock resistance
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Ground
0 to 55°C (with no icing)
10% to 90% (with no condensation)
−20 to 75°C (with no icing)
10% to 90% (with no condensation)
Ground to 100 Ω or less.
Installed in panel
Approx. 700 g
Ground to 100 Ω or less.
Installed in panel
Approx. 800 g
Construction
Weight
Electromagnetic Coupling RFID System V600
9
■ Transmission Distance Specifications for Battery-less Data Carriers
with Small Memory Capacity
Recommended combinations
Data Carrier R/W Head
V600-D23P71 V600-H07
Installation
Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Stationary Read dis-
tance
Irrelevant
10 to 70 mm (max. axi- These Data Carriers are for installa-
al offset ±10 mm)
tion on non-metallic surfaces only.
Write dis-
tance
V600-D23P71/72
Data Carrier
R/W Head
Moving
Read dis-
tance
30 to 60 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
Iron
Non-metallic
(Resin, plastic, wood, etc.)
V600-H11/-H11-R
Stationary Read dis-
tance
Irrelevant
Irrelevant
Irrelevant
5 to 40 mm (max. axial
offset ±10 mm)
Data transmission will be impossi-
ble if the DC is installed directly on
a metal surface. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
Write dis-
tance
Moving
Read dis-
tance
15 to 40 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
V600-D23P72 V600-H07
Stationary Read dis-
tance
10 to 50 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
Moving
Read dis-
tance
30 to 40 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
V600-H11/-H11-R
Stationary Read dis-
tance
5 to 30 mm (max. axial
offset ±10 mm)
Write dis-
tance
Moving
Read dis-
tance
15 to 30 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
10
Electromagnetic Coupling RFID System V600
Recommended combinations
Data Carrier R/W Head
V600-D23P66N V600-H07
Installation
Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Stationary Read dis-
tance
Transmission
distance priority offset ±10 mm)
5 to 45 mm (max. axial
R/W Head
Data Carrier
Transmission
time priority
5 to 35 mm (max. axial
offset ±10 mm)
Iron
Write dis-
tance
Irrelevant
5 to 35 mm (max. axial
offset ±10 mm)
Non-metallic
(Resin, plastic, wood, etc.)
Moving
Read dis-
tance
Transmission
distance priority al offset ±10 mm)
25 to 40 mm (max. axi-
Data transmission will be impossi-
ble if the DC is installed directly on
a metal surface. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
Transmission
time priority
25 to 30 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
Irrelevant
25 to 30 mm (max. axi-
al offset ±10 mm)
V600-H11/-H11-R
Stationary Read dis-
tance
Transmission
distance priority offset ±10 mm)
5 to 30 mm (max. axial
Transmission
time priority
5 to 25 mm (max. axial
offset ±10 mm)
Write dis-
tance
Irrelevant
5 to 25 mm (max. axial
offset ±10 mm)
Moving
Read dis-
tance
Transmission
distance priority al offset ±10 mm)
15 to 25 mm (max. axi-
Transmission
time priority
15 to 20 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
Irrelevant
15 to 20 mm (max. axi-
al offset ±10 mm)
V600-
D23P66SP
V600-H07
Stationary Read dis-
tance
Transmission
distance priority offset ±10 mm)
5 to 40 mm (max. axial
Transmission
time priority
5 to 30 mm (max. axial
offset ±10 mm)
Write dis-
tance
Irrelevant
5 to 30 mm (max. axial
offset ±10 mm)
Moving
Read dis-
tance
Transmission
distance priority al offset ±10 mm)
20 to 40 mm (max. axi-
Transmission
time priority
20 to 30 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
Irrelevant
20 to 30 mm (max. axi-
al offset ±10 mm)
V600-H11/-H11-R
Stationary Read dis-
tance
Transmission
distance priority offset ±10 mm)
5 to 25 mm (max. axial
Transmission
time priority
5 to 20 mm (max. axial
offset ±10 mm)
Write dis-
tance
Irrelevant
5 to 20 mm (max. axial
offset ±10 mm)
Moving
Read dis-
tance
Transmission
distance priority al offset ±10 mm)
10 to 25 mm (max. axi-
Transmission
time priority
10 to 20 mm (max. axi-
al offset ±10 mm)
Write dis-
tance
Irrelevant
10 to 20 mm (max. axi-
al offset ±10 mm)
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
Electromagnetic Coupling RFID System V600
11
Recommended combinations
Data Carrier R/W Head
V600-D23P61 V600-H11/-H11-R
Installation
Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Stationary Read dis-
tance
Transmission
distance priority offset ±10 mm)
2 to 19 mm (max. axial These Data Carriers can be in-
stalled on metallic surfaces.
Transmission
time priority
2 to 16 mm (max. axial
offset ±10 mm)
V600-D23P61
Data Carrier
Write dis-
tance
Irrelevant
2 to 16 mm (max. axial
offset ±10 mm)
V600-H51
R/W Head
Moving
Read dis-
tance
Transmission
distance priority al offset ±10 mm)
12 to 19 mm (max. axi-
Iron
Transmission
time priority
12 to 16 mm (max. axi-
al offset ±10 mm)
Iron (SC, SS)
V600-H11
R/W Head
V600-D23P61
Data Carrier
Write dis-
tance
Irrelevant
12 to 16 mm (max. axi-
al offset ±10 mm)
V600-H51
Stationary Read dis-
tance
Transmission
distance priority offset ±10 mm)
1 to 16 mm (max. axial
Iron
Transmission
time priority
1 to 14 mm (max. axial
offset ±10 mm)
Iron (SC, SS)
The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
7 to 14 mm (max. axial
No. Z128) for details.
Write dis-
tance
Irrelevant
1 to 14 mm (max. axial
offset ±10 mm)
Moving
Read dis-
tance
Transmission
distance priority offset ±10 mm)
7 to 16 mm (max. axial
Transmission
time priority
offset ±10 mm)
Write dis-
tance
Irrelevant
7 to 14 mm (max. axial
offset ±10 mm)
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
12
Electromagnetic Coupling RFID System V600
Recommended combinations
Data Carrier R/W Head
Installation
Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
0.5 to 4.0
mm (max.
0.5 to 4.5
mm (max.
V600-D23P53 V600-HS51
(See note 4.)
Stationary Read dis-
tance
Transmission
distance priority
These Data Carriers are for flush
mounting in metallic bases only.
axial offset axial offset
±2 mm)
±1 mm)
V600-D23P53/54
Data Carrier
V600-HS61
R/W Head
0.5 to 3.0
mm (max.
0.5 to 3.5
mm (max.
Transmission
time priority
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 3.0
mm (max.
0.5 to 3.5
mm (max.
Write dis-
tance
Irrelevant
axial offset axial offset
Iron
±2 mm)
±1 mm)
Iron
(SC, SS)
0.5 to 4.0
mm (max.
0.5 to 4.5
mm (max.
V600-HS61
(See note 4.)
Stationary Read dis-
tance
Transmission
distance priority
axial offset axial offset
V600-D23P53/54
Data Carrier
±2 mm)
±1 mm)
0.5 to 3.0
mm (max.
0.5 to 3.5
mm (max.
Transmission
time priority
axial offset axial offset
V600-HS51
R/W Head
±2 mm)
±1 mm)
0.5 to 3.0
mm (max.
0.5 to 3.5
mm (max.
Write dis-
tance
Irrelevant
axial offset axial offset
Iron
Iron(SC, SS)
±2 mm)
±1 mm)
0.5 to 4.0
mm (max.
0.5 to 4.5
mm (max.
V600-H52
Stationary Read dis-
tance
Transmission
distance priority
V600-D23P53/54
Data Carrier
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 3.0
mm (max.
0.5 to 3.5
mm (max.
Transmission
time priority
V600-H52
R/W Head
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 3.0
mm (max.
0.5 to 3.5
mm (max.
Write dis-
tance
Irrelevant
Iron
Iron(SC, SS)
axial offset axial offset
The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
±2 mm)
±1 mm)
0.5 to 6.0
mm (max.
0.5 to 6.5
mm (max.
V600-D23P54 V600-HS51
(See note 4.)
Stationary Read dis-
tance
Transmission
distance priority
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 5.5
mm (max.
axial offset axial offset
±2 mm)
0.5 to 6.0
mm (max.
Transmission
time priority
±1 mm)
0.5 to 5.0
mm (max.
0.5 to 5.5
mm (max.
Write dis-
tance
Irrelevant
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 6.5
mm (max.
0.5 to 7.0
mm (max.
V600-HS61
(See note 4.)
Stationary Read dis-
tance
Transmission
distance priority
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 5.5
mm (max.
0.5 to 6.0
mm (max.
Transmission
time priority
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 5.5
mm (max.
0.5 to 6.0
mm (max.
Write dis-
tance
Irrelevant
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 6.5
mm (max.
0.5 to 7.0
mm (max.
V600-H52
Stationary Read dis-
tance
Transmission
distance priority
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 5.5
mm (max.
0.5 to 6.0
mm (max.
Transmission
time priority
axial offset axial offset
±2 mm)
±1 mm)
0.5 to 5.5
mm (max.
0.5 to 6.0
mm (max.
Write dis-
tance
Irrelevant
axial offset axial offset
±2 mm)
±1 mm)
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.
Electromagnetic Coupling RFID System V600
13
Recommended combinations
Data Carrier R/W Head
Installation
Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
V600-D23P55 V600-HS51
(See note 4.)
Stationary Read dis-
tance
Transmission
distance priority axial offset ±2 mm)
0.5 to 6.5 mm (max.
These Data Carriers are for flush
mounting in non-metallic bases
only.
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
V600-D23P55
Data Carrier
Write dis-
tance
Transmission
distance priority axial offset ±2 mm)
0.5 to 6.5 mm (max.
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
V600-HS51
R/W Head
V600-HS61
(See note 4.)
Stationary Read dis-
tance
Transmission
distance priority axial offset ±2 mm)
0.5 to 7.0 mm (max.
Iron
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
Non-metallic
(Resin, plastic, wood, etc.)
Write dis-
tance
Transmission
distance priority axial offset ±2 mm)
0.5 to 7.0 mm (max.
V600-D23P55
Data Carrier
V600-HS61
R/W Head
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
V600-H52
Stationary Read dis-
tance
Transmission
distance priority axial offset ±2 mm)
0.5 to 9.0 mm (max.
Transmission
time priority
0.5 to 8.5 mm (max.
axial offset ±2 mm)
Iron
Non-metallic
(Resin, plastic, wood, etc.)
Write dis-
tance
Transmission
distance priority axial offset ±2 mm)
0.5 to 8.5 mm (max.
Transmission
time priority
0.5 to 8.5 mm (max.
axial offset ±2 mm)
V600-D23P55
Data Carrier
V600-H52
R/W Head
Iron
Non-metallic
(Resin, plastic, wood, etc.)
The transmission distance decreas-
es considerably when flush mount-
ed in non-metallic bases. Refer to
the V600 R/W Heads and EEPROM
Data Carriers Operation Manual
(Cat. No. Z128) for details.
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.
14
Electromagnetic Coupling RFID System V600
■ Transmission Distance Specifications for Data Carriers with Large
Memory Capacity (Built-in-battery/Battery-less/Replaceable-battery)
Recommended combinations
Data Carrier R/W Head
V600-D8KR12 V600-H07
Installation
Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Stationary Flush-mount- Irrelevant
ed in metal
10 to 50 mm (max. axi-
al offset ±10 mm)
R/W Head
Metal
Surface-
mounted on
metal
10 to 60 mm (max. axi-
al offset ±10 mm)
Moving
Flush-mount-
ed in metal
25 to 50 mm (max. axi-
al offset ±10 mm)
Data Carrier
Surface-mounted on metal
Surface-
mounted on
metal
25 to 60 mm (max. axi-
al offset ±10 mm)
Metal
V600-H11
Stationary Flush-mount- Irrelevant
ed in metal
5 to 40 mm (max. axial
offset ±10 mm)
Surface-
mounted on
metal
5 to 45 mm (max. axial
offset ±10 mm)
Data Carrier
Flush-mounted in metal
Moving
Flush-mount-
ed in metal
25 to 40 mm (max. axi-
al offset ±10 mm)
Metal
Surface-
mounted on
metal
25 to 45 mm (max. axi-
al offset ±10 mm)
The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and SRAM Data Carri-
ers Operation Manual (Cat. No.
Z127) for details.
V600-D8KR13 V600-H07
Stationary Flush-mount- Irrelevant
ed in metal
10 to 30 mm (max. axi-
al offset ±10 mm)
Surface-
mounted on
metal
10 to 35 mm (max. axi-
al offset ±10 mm)
Moving
Flush-mount-
ed in metal
20 to 30 mm (max. axi-
al offset ±10 mm)
Surface-
mounted on
metal
20 to 35 mm (max. axi-
al offset ±10 mm)
V600-H11
Stationary Flush-mount- Irrelevant
ed in metal
10 to 30 mm (max. axi-
al offset ±10 mm)
Surface-
mounted on
metal
Moving
Flush-mount-
ed in metal
15 to 30 mm (max. axi-
al offset ±10 mm)
Surface-
mounted on
metal
Electromagnetic Coupling RFID System V600
15
Recommended combinations
Data Carrier R/W Head
Installation
Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
V600-D8KR04 V600-H07
(unsealed)
Stationary Flush-mount- Irrelevant
ed in metal
See note1.
The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and SRAM Data Carri-
ers Operation Manual (Cat. No.
Z127) for details.
Surface-
mounted on
metal
10 to 100 mm (max.
axial offset ±10 mm)
Moving
Flush-mount-
ed in metal
See note1.
Surface-
mounted on
metal
50 to 100 mm (max.
axial offset ±10 mm)
V600-H11
V600-D8KF04 V600-H07
V600-H11
Stationary Flush-mount- Irrelevant
ed in metal
See note1.
Surface-
mounted on
metal
10 to 65 mm (max. axi-
al offset ±10 mm)
Moving
Flush-mount-
ed in metal
See note1.
Surface-
mounted on
metal
30 to 65 mm (max. axi-
al offset ±10 mm)
Stationary Flush-mount- Irrelevant
ed in metal
See note1.
Surface-
mounted on
metal
10 to 50 mm (max. axi-
al offset ±10 mm)
Moving
Flush-mount-
ed in metal
See note1.
Surface-
mounted on
metal
25 to 50 mm (max. axi-
al offset ±10 mm)
Stationary Flush-mount- Irrelevant
ed in metal
See note1.
Surface-
mounted on
metal
10 to 32 mm (max. axi-
al offset ±10 mm)
Moving
Flush-mount-
ed in metal
See note1.
Surface-
mounted on
metal
15 to 32 mm (max. axi-
al offset ±10 mm)
V600-D2KR16 V600-H11
Stationary Flush-mount- Irrelevant
ed in metal
2 to 15 mm (max. axial
offset ±10 mm) (See
note 2.)
Surface-
mounted on
metal
2 to 15 mm (max. axial
offset ±10 mm)
Moving
Flush-mount-
ed in metal
6 to 15 mm (max. axial
offset ±10 mm) (See
note 2.)
Surface-
mounted on
metal
10 to 15 mm (max. axi-
al offset ±10 mm)
Note: 1. When Data Carriers are flush-mounted in metal, the read/
write distance will depend on the distance (x) between the
side of the DC and the metal surface.
2. Use the following method for flush mounting into a metallic
base.
10 mm min.
10 mm min.
Flush-mounted
mm
mm
Flush-mounted
Refer to the V600 R/W
Heads and SRAM Data
Carriers Operation Manual
(Cat. No. Z127) for details.
Metal
20 mm max.
Metal
16
Electromagnetic Coupling RFID System V600
■ Influence of Surrounding Metal
V600-D8KR04 Combined with V600-H07
V600-D8KR04 Combined with V600-H11
(Axial offset: ±0 mm)
(Axial offset: ±0 mm)
100
80
60
40
100
R/W Head
Data Carrier
R/W Head
Data Carrier
50
20
0
0
20
40
60
80
∞
20
40
60
80
(Above 100)
Distance from metal surface ( ) (mm)
∞
(Above 100)
Distance from metal surface ( ) (mm)
V600-D8KF04 Combined with V600-H07
V600-D8KF04 Combined with V600-H11
(Axial offset: ±0 mm)
70
(Axial offset: ±0 mm)
70
60
50
40
30
60
50
40
30
R/W Head
Data Carrier
R/W Head
Data Carrier
20
10
20
10
0
20
40
60
80
100
0
20
40
60
80
100
(Above 100)
(Above 100)
Distance from metal surface ( ) (mm)
Distance from metal surface ( ) (mm)
Electromagnetic Coupling RFID System V600
17
Lower-level Communications Mode Setting (Distance/Time Priority)
The lower-level communications mode is set with the DIP Switch or memory switch on the Serial-interface Controller (V600-CA5D02, V600-CD1D-
V3, V600-CM1D) or ID Sensor Unit. (Refer to the Controller’s operation manual for more details on the setting.)
Characteristic Data (Typical)
■ Transmission Range
Note: The values shown in the following graphs are in millimeters. Refer to pages 10 to 16 for details on Data Carrier and R/W Head mounting
conditions.
Battery-less Data Carriers with Small Memory Capacity
V600-D23P71 & V600-H07
V600-D23P71 & V600-H11
Y
Y
Y
Y
80
100
80
60
40
20
X
60
40
20
X
–120 –100 –80 –60 –40 –20
0
20 40 60 80 100 120
X
–100 –80 –60 –40 –20
0
20
40
60
80 100 X
V600-D23P72 & V600-H07
V600-D23P72 & V600-H11
Y
Y
Y
Y
60
100
80
60
40
20
X
X
40
20
–
120
–
100
–
80
–
60
–
40
–
20
0
20 40 60 80 100 120
X
–80
–60
–40
–20
0
20
40
60
80
80
80
40
X
X
X
X
V600-D23P66N & V600-H07
V600-D23P66N & V600-H11
Y
Y
Y
Y
60
80
X
X
60
40
20
40
20
–80
–60
–40
–20
0
20
40
40
20
60
–100 –80 –60 –40 –20
0
20
40
40
20
60
60
30
80 100 X
V600-D23P66SP & V600-H07
V600-D23P66SP & V600-H11
Y
Y
Y
Y
80
60
X
60
40
20
X
40
20
–100 –80 –60 –40 –20
0
20
80 100 X
–80
–60
–40
–20
0
20
60
Y
V600-D23P61 & V600-H11
V600-D23P61 & V600-H51
Y
Y
Y
40
30
X
X
30
20
10
20
10
–50 –40 –30 –20 –10
0
10
40
50
X
–40
–30
–20
–10
0
10
30
Write range (in transmission distance or transmission time priority mode)
Read range (in transmission time priority mode)
Read range (in transmission distance priority mode)
18
Electromagnetic Coupling RFID System V600
V600-D23P53 & V600-HS51
+V600-HA51
V600-D23P53 & V600-HS61
+V600-HA51
V600-D23P53 & V600-H52
Y
Y
Y
Y
Y
Y
10
10
10
X
X
X
5
5
5
–10
–5
0
5
10 X
–10
–5
0
5
10
X
–10
–5
0
5
10 X
V600-D23P54 & V600-HS51
+V600-HA51
V600-D23P54 & V600-HS61
+V600-HA51
V600-D23P54 & V600-H52
Y
Y
Y
Y
Y
Y
15
15
15
X
X
X
10
5
10
5
10
5
X
–15
–10
–5
0
5
10
15
–15
–10
–5
0
5
10
15
X
–15
–10
–5
0
5
10
15
X
V600-D23P55 & V600-HS51
+V600-HA51
V600-D23P55 & V600-HS61
+V600-HA51
V600-D23P55 & V600-H52
Y
Y
Y
Y
Y
Y
15
15
15
10
5
X
X
X
10
5
10
5
–15
–10
–5
0
5
10
15
X
–15
–10
–5
0
5
10
15
X
–15
–10
–5
0
5
10
15
X
Write range (in transmission distance or transmission time priority mode)
Read range (in transmission time priority mode)
Read range (in transmission distance priority mode)
Electromagnetic Coupling RFID System V600
19
Built-in-battery Data Carriers with Large Memory Capacity
V600-D8KR12 & V600-H07
V600-D8KR12 & V600-H11
Y
Y
Y
Y
80
60
X
X
60
40
20
40
20
–100 –80 –60 –40 –20
0
20
40
60
80 100 X
–80
–60
–40
–20
0
20
40
60
80 X
V600-D8KR13 & V600-H07
V600-D8KR13 & V600-H11
Y
Y
Y
Y
80
60
X
X
60
40
20
40
20
–100 –80 –60 –40 –20
0
20
40
60
80 100 X
–80
–60
–40
–20
0
20
40
60
80 X
V600-D8KR04 & V600-H07
V600-D8KR04 & V600-H11
Y
Y
Y
Y
120
80
X
X
60
40
20
80
40
–160
–120
–80
–40
0
40
80
120
160 X
–100 –80 –60 –40 –20
0
20
40
60
80 100 X
Battery-less Data Carriers with Large Memory Capacity
V600-D8KF04 & V600-H07
V600-D8KF04 & V600-H11
Y
Y
Y
Y
80
80
X
X
60
40
20
60
40
20
−100 −80 −60 −40 −20
0
20
40
60
80 100 X
−100 −80 −60 −40 −20
0
20
40
60
80 100 X
Replaceable-battery Data Carriers with Large Memory Capacity
V600-D2KR16 & V600-H11
Y
Y
60
X
40
20
–80
–60
–40
–20
0
20
40
60
80 X
Read/Write range (in transmission distance or transmission time priority mode)
20
Electromagnetic Coupling RFID System V600
■ Communications Time
• The communications time does not depend on the model of R/W
Head or Data Carrier, although communications times differ
between Data Carriers with and without batteries.
• The lower-level communications time does not include the host
communications; it is the time required for communications
between the R/W Head and Data Carrier. The lower-level commu-
nications time is used in the equation for the DC speed.
• The turn around time (TAT) is the total time required from the issu-
ance of a command from the host device (for example, a host com-
puter) until the reception of a response.
DC Speed = (Distance travelled in the transmission range)/
(Lower-level communications time)
RDH1……………*
Command
RD001122……………*
Response
Lower-level communications time
TAT (Turn Around Time)
Lower-level Communications Time with
Built-in-battery Data Carriers (Reference)
1,000
Lower-level Communications Time with
Battery-less Data Carriers (Reference)
(Battery-less Models Excluding V600-
D8KF04)
2,500
800
Transmission distance priority mode
Transmission time priority mode
(Auto) Write
600
2,000
(Auto) Write
1,500
400
1,000
200
0
(Auto) Read
(Auto) Read
500
1
50
100
150
200
250 300
Number of bytes
0
50
100
150
200
250 300
Calculation (Reference)
Number of bytes
Lower-level communications time
(ms)
Calculation (Reference)
R/W
READ
t = 1.8 N + 48.4
t = 4.2 N + 86.5
Lower-level communications
time (ms)
WRITE
N is the number of processing bytes.
Distance
priority mode
READ
WRITE
READ
WRITE
t = 4.3 N + 64.6
t = 8.7 N + 167.1
t = 1.8 N + 79.0
t = 7.1 N + 180.4
V600-D8KF04 (Battery-less)
1,000
Time priority
mode
N is the number of processing bytes.
800
600
(Auto)Write
400
200
0
(Auto)Read
1
50
100
150
200
250 300
Number of bytes
Calculation (Reference)
Lower-level communications time
(ms)
READ
t = 1.8 N + 168.4
t = 4.2 N + 206.5
WRITE
N is the number of processing bytes.
Electromagnetic Coupling RFID System V600
21
■ Battery Life
The Data Carrier has a built-in lithium battery.
The following graphs show the relationship between the number of bytes per transmission, the number of transmissions per day, and the battery life.
V600-D8KR12 (Typical Example)
V600-D8KR04 (Typical Example)
V600-D8KR13 (Typical Example)
5 years
5 years
5 years
8 years
8 years
8 years
Number of bytes/transmission
Number of bytes/transmission
Number of bytes/transmission
■ Temperature and Battery Life
V600-D2KR16
The battery life is two years at 25°C regardless of the relationship between the number of bytes read/written and the number of transmissions.
Examples Showing Relationship between Battery Life and Temperature
The following table shows the standard values.
2.5
Temperature
20°C
Battery consumption rate in one year
1%
2%
2
1.5
1
30°C
40°C
50°C
60°C
4%
8%
16%
32%
70°C
Note: If the battery is stored at 70°C and is not installed, the battery
0.5
life is calculated as follows:
2 (years) × (1 - 0.32) = 1.36 years
If the battery is stored at 25°C after one year’s storage, the bat-
tery life will be approximately 1 year and 4 months. (The battery
life will be shortened if the battery is used at temperatures close
to 0°C or 50°C.)
0
10
20
30
40
50
Ambient temperature (˚C)
The values in the above graph are based on the battery being installed (i.e., the insulation sheet is removed). If the battery is not installed, the
values shown in the above table will apply.
22
Electromagnetic Coupling RFID System V600
Precautions
Data Carrier Batteries
Built-in-battery Data Carriers
Replaceable-battery Data Carriers
WARNING
WARNING
The SRAM-type Data Carrier has a built-in lithium
battery which may occasionally ignite, explode, and
burn if mishandled. Do not disassemble, deform,
heat above 212°F (100°C), or incinerate the Data
Carrier.
The SRAM-type Data Carrier has replaceable lithium
batteries which may occasionally take fire, explode,
burn, or leak liquid if mishandled. Do not deform,
heat above 212°F (100°C), incinerate, or charge the
batteries, or short-circuit their positive and negative
terminals.
■ Mutual Interference (Reference Values)
Mutual Interference between R/W Heads
When more than one set of R/W Heads are used, mutual interference between the Heads can be avoided by mounting the Heads at the specified
distance as shown below.
V600-H07
V600-H11
• Facing
• Facing
RD/WT command: 650 mm min.
Auto command: 900 mm min.
RD/WT command: 200 mm min.
Auto command: 200 mm min.
650 mm min.
200 mm min.
(900 mm min.)
• Side-by-side
• Side-by-side
RD/WT command: 550 mm min.
Auto command: 1,200 mm min.
RD/WT command: 200 mm min.
Auto command: 200 mm min.
200 mm min.
550 mm min.
(1,200 mm min.)
Electromagnetic Coupling RFID System V600
23
V600-H51
V600-H52
V600-HS51
• Facing: 120 mm min.
• Facing: 80 mm min.
• Facing: 80 mm min.
V600-H51
V600-H51
V600-H52
V600-H52
V600-HS51
V600-HS51
80 mm min.
120 mm min.
80 mm min.
• Side-by-side: 100 mm min.
• Side-by-side: 80 mm min.
• Side-by-side: 80 mm min.
80 mm min.
80 mm min.
100 mm min.
V600-HS51
V600-HS51
V600-H51
V600-H51
V600-H52
V600-H52
V600-HS61
• Facing: 80 mm min.
• Side-by-side: 80 mm min.
V600-HS61
V600-HS61
V600
V600
-HS61
-HS61
80 mm min.
80 mm min.
Note: If the two R/W Heads are not transmitting simultaneously (i.e., independent read/write), mutual interference will not occur. Therefore, the
restriction on the distance between the Heads will not be applicable.
The commands will be received by the R/W Heads and transmission will oscillate between them.
Mutual Interference between Proximity Sensors
The V600-series Units use electromagnetic coupling (frequency: 530 kHz). When a V600 Unit is wired close to R/W Heads, Proximity Switches,
and Sensors that have an oscillating frequency between 400 and 600 kHz, the Proximity Sensor may malfunction, so be sure to install the Units
according to the distance restrictions specified in the following diagrams. Make sure to thoroughly test that the mounting positions and the fixed
positions of the Sensors are correct before putting them into actual operation.
• Facing: 300 mm min.
V600-H07
• Vertical/Parallel: 400 mm min.
300 mm min.
V600-H07
Proximity Sensor
Proximity Sensor
400 mm min.
400 mm min.
Proximity Sensor
V600-H07
24
Electromagnetic Coupling RFID System V600
• Facing: 100 mm min.
V600-H11
• Vertical/Parallel: 100 mm min.
100 mm min.
V600-H11
Proximity Sensor
Proximity Sensor
100 mm min.
100 mm min.
V600-H11
Proximity Sensor
V600-H51/H52
V600-HS51
V600-HS61
100 mm min.
V600-HS61
Proximity Sensor
Proximity Sensor
Proximity Sensor
100 mm min.
100 mm min.
Proximity Sensor
Proximity Sensor
Proximity Sensor
V600-HS51
V600-H51/52
200 mm min.
200 mm min.
100 mm min.
100 mm min.
150 mm min.
150 mm min.
Proximity Sensor
Proximity Sensor
V600-HS61
Proximity Sensor
Electromagnetic Coupling RFID System V600
25
Mutual Interference between Data Carriers
When more than one Data Carrier is used, mutual interference between the DCs can be avoided by making sure that they are mounted apart at
the distances specified below.
Reading/Writing
V600-D23P53
V600-D23P54
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
40 mm min.
45 mm min.
V600-D23P55
V600-D23P61
R/W Head: V600-H11/-H51
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
50 mm min.
90 mm min.
V600-D23P66N
R/W Head: V600-H11
V600-D23P66SP
R/W Head: V600-H11
140 mm min.
140 mm min.
R/W Head: V600-H07
R/W Head: 600-H07
160 mm min.
160 mm min.
V600-D23P72
R/W Head: V600-H11
R/W Head: V600-H07
210 mm min.
170 mm min.
180 mm min.
140 mm min.
V600-D23P71
R/W Head: V600-H07
290 mm min.
210 mm min.
26
Electromagnetic Coupling RFID System V600
V600-D8KR12
R/W Head: V600-H11
R/W Head: V600-H07
140 mm min.
160 mm min.
140 mm min.
160 mm min.
V600-D8KR13
R/W Head: V600-H11
R/W Head: V600-H07
160 mm min.
180 mm min.
160 mm min.
160 mm min.
V600-D8KR04/V600-D8KF04
R/W Head: V600-H11
R/W Head: V600-H07
220 mm min.
180 mm min.
180 mm min.
V600-D2KR16
R/W Head: V600-H11
150 mm min.
90 mm min.
Electromagnetic Coupling RFID System V600
27
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Data Carriers with Large Memory Capacity
Built-in-battery DCs
V600-D8KR12
V600-D8KR13
65
86
0.2
55±
Two, 4.5-dia. mounting holes
10
5
10
27
Two, 4.5-dia. mounting holes
10
27
10
0.2
54 44±0.2
40 30±
76±0.2
Case: ABS resin
Filler: Epoxy resin
5
15
8
Case: ABS resin
Filler: Epoxy resin
10.3
5
V600-D8KR04
86
31
5
Four, 4.5-dia. mounting holes
0.2
5
76±
0.2
54 44±
Case: ABS resin
Filler: Epoxy resin
20
10
Replaceable-battery DCs
V600-D2KR16
4-R1.5
65
40
R0.5
Case: ABS resin
5
Battery-less DCs
V600-D8KF04
86
31
Four, 4.5-dia. mounting holes
0.2
5
5
76±
0.2
54 44±
20
Case: ABS resin
Filler: Epoxy resin
10
28
Electromagnetic Coupling RFID System V600
Data Carriers with Small Memory Capacity
Battery-less DCs
V600-D23P53
V600-D23P54
V600-D23P55
V600-D23P61
36
0.1
30±
24
0
R0.3
12 – 0.2dia.
R0.2
R0.2
0
0
8
– 0.1dia.
8
– 0.1dia.
24
2-R1.0
0
Two, 3.5-dia. mounting holes
0
5 – 0.1
5 – 0.1
0
6 – 0.2
6
2.2
Case: ABS resin
Filler: Epoxy resin
Case: ABS resin
Filler: Epoxy resin
Case: PPS resin
Filler: Epoxy resin
Case: ABS resin
Filler: Epoxy resin
V600-D23P66N
V600-D23P66SP
Mounting Hole Dimensions
2-M3
Two, 5.5-dia.
mounting holes
4-R6
Mounting Hole Dimensions
2-M5
34
4-R4
0.2
25±
4-R3
34
36.5
0.2
0.2
80±
0.2
25±
25±
34 32
Two, 3.5-dia.
Two, 6-dia.
Coating: PFA resin
0.2
6.5
25±
1.3
0.1
32
34
3.5±
0.2
80±
2.5 max.
Case: PPS resin
95
V600-D23P71
V600-D23P72
4-R2
4-R2
50
86
34
54
Case: Glass epoxy resin
Coating: Polyurethane resin
1.5
Case: Glass epoxy resin
Coating: Polyurethane resin
1.5
Electromagnetic Coupling RFID System V600
29
R/W Heads
V600-H07
Four, 4.5-dia.
mounting holes
100
0.2
90±
5
5
50
50
Power indicator
(green)
25
43
100
90±
14.7 dia.
0.2
Transmission
indicators
(orange)
Vinyl-insulated Connector
round cord
(6-mm dia.)
Bushing
10
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
14
10
30
20
11
V600-H11
Vinyl-insulated round cord (6-mm dia.)
Connector
4-R1
28
Two, 4.5-dia. mounting holes
Bushing
2-R5
Accessories: Two brackets
for rear panel mounting
10
40
14.7 dia.
43
5
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
5
27
6
5
13
18
Power (green)/transmission
(orange) indicators
53
20
23
11
V600-H51
V600-H52
80
(72)
(66)
62.5
85
(77)
(71)
67.5
12
7
43
43
12 dia.
14.7 dia.
14.7 dia.
19.8 dia.
Connector
Connector
Vinyl-insulated round cord (6-mm dia.)
Vinyl-insulated round cord (6-mm dia.)
M22X1
2 lock washers
M22X1
Power (green)/transmission (orange) indicators
Power (green)/transmission (orange) indicators
2 lock nuts
2 lock washers
2 lock nuts
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
Cable: PVC (oil-resistant)
V600-HS51 (Sensor Section)
V600-HS61 (Sensor Section)
2 lock washers
Vinyl-insulated round cord
(4-mm dia.)
30.5
4.5
8.5
2 lock nuts
M12X1
18
Connector
49.5
0.1
12±
9.6 dia.
13.7 dia.
18
13.7 dia.
7
Connector
49.5
Transmission surface
Two, 3.5x5
mounting holes
33
35
Vinyl-insulated round cord
(4-mm dia.)
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Case: ABS resin
Filler: Epoxy resin
10
Cable: PVC (oil-resistant)
6.5
Cable: PVC (oil-resistant)
30
Electromagnetic Coupling RFID System V600
V600-HA51 (Amplifier Section)
Operating indicator (orange)
Power indicator (green)
12.8 dia.
22.6 22
51.7
5.9
61.8
5
(10,000)
43
Connector
13.7 dia.
8
14.7 dia.
36.5
23.5
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
Vinyl-insulated round cord
6-mm dia (7/0.18-mm dia.),
8-conductor cable
Connector
0.2
51.3±
4
6.1
35.6
Two, 4.5-dia. mounting holes
13.2
ID Controllers
V600-CA5D02 (Compact)
Two, 4.5-dia.
mounting holes
105
95
80
5
65
18
90
80
17.5
5
7.5
V600-CD1D-V3 (Compact)
18
68
53
17.5
50
5.5
81
92
80
Two, 4.5-dia.
115
V600-CM1D (Board-mounted)
102
92
78
76
9
16.5
21.5
5
6
57.4
95
86.3
107
Four, 3.5-dia.
R/W Head connector
Electromagnetic Coupling RFID System V600
31
■ Accessories
Holder
V600-A81
68
0.1
8-R0.5
40±
0.1
24±
20
42
(Four, 3.5-dia.)
(Four, 5.5-dia.)
Case: ABS resin
2-R2.5
9
3.5
V600-A84
Use M3 countersunk screws in the two 3.2-dia.
mounting holes or apply ultrasonic welding.
0.5
99.8±
8.5
5
4-R3
2.1
24.4
42.5
0.5
67.8±
63.6
2.1
2.1
2.1
95.6
Attachment
V600-A86
Material: PPS resin
Two, 4-dia.
4-R5.5
0.2
25±
0.2
34 15
16
37
25±
15
34
37
4
3.5
10
Mounting Hole Dimensions
2-M3
0.2
25±
0.2
25±
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
32
Electromagnetic Coupling RFID System V600
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of
sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate
catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use
of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other
application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the
products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,
and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of
Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or
proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
Cat. No. Q124-E1-03
2007.3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.