VAQR-4B [OMRON]

Pushbutton Switch, SPDT, Momentary, 15A, 8VDC, Quick Connect Terminal, Panel Mount-threaded;
VAQR-4B
型号: VAQR-4B
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Pushbutton Switch, SPDT, Momentary, 15A, 8VDC, Quick Connect Terminal, Panel Mount-threaded

开关 光电二极管
文件: 总5页 (文件大小:360K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Pushbutton Switch (Cylindrical 10.5-dia.)  
VAQ  
CSM_VAQ_DS_E_4_1  
Built-in V-series Miniature Basic  
Switch for Compatibility with  
Business and Consumer Equipment  
• Momentary operation and lock.  
• Operation Unit available in six colors.  
• Improved sense of touch with built-in miniature basic switch.  
Refer to Safety Precautions for All Pushbutton Switches  
and Safety Precautions on page 4.  
Ordering Information  
Operation Unit color  
Classifica-  
tion  
Shape of  
Out-  
put  
Operation Unit  
Blue (-A)  
Black (-B)  
VAQ-4B-K  
Green (-G)  
Red (-R)  
White (-W)  
Yellow (-Y)  
VAQ-4Y-K  
1 *1  
1 *2  
2 *2  
1 *2  
VAQ-4A-K  
VAQ-4G-K  
VAQ-4G-L  
2VAQ-4G  
VAQR-4G  
VAQ-4R-K  
VAQ-4W-K  
VAQ-4W-L  
2VAQ-4W  
VAQR-4W  
Momentary  
operation  
13 dia.  
VAQ-4A-L  
2VAQ-4A  
VAQR-4A  
VAQ-4B-L  
2VAQ-4B  
VAQR-4B  
VAQ-4R-L  
2VAQ-4R  
VAQR-4R  
VAQ-4Y-L  
2VAQ-4Y  
11.4  
Lock  
*2  
*1. The Operation Unit can be inserted and removed.  
*2. The Operation Unit is screwed in.  
Specifications  
Ratings  
Non-inductive load (A)  
Inductive load (A)  
Inductive  
Item  
Rated  
voltage (V)  
Resistive  
load  
Lamp load  
Motor load  
Built-in Switch  
load  
125 VAC  
250 VAC  
8 VDC  
15  
15  
15  
10  
0.6  
0.3  
2
10  
3
2
10  
3
4
10  
6
V-15-1A5  
30 VDC  
125 VDC  
250 VDC  
4
10  
4
0.1  
0.05  
0.6  
0.3  
0.1  
0.05  
Note: 1. The above values are for steady-state currents.  
2. Inductive load: Power factor = 0.4 (AC); time constant = 7 ms (DC).  
3. The lamp load has an inrush current of 10 times the steady-state current.  
4. The motor load has an inrush current of 6 times the steady-state current.  
5. The rated values above are for testing conducted under the following conditions.  
(1) Ambient temperature: 20 2°C.  
(2) Ambient humidity: 65% 5%RH  
(3) Operating frequency: 20 times/min.  
1
VAQ  
Specifications  
Characteristics  
Operating Characteristics  
Mechanical  
Electrical  
120 operations/min  
Operating  
frequency  
Output  
1
2
20 operations/min  
Operating characteristics  
Insulation resistance  
Contact resistance  
100 MΩ min. (at 500 VDC)  
30 mΩ max. (initial value)  
Operating force  
Releasing force  
Pretravel  
OF max.  
RF min.  
PT max.  
1.96 N  
0.39 N  
1.3 mm  
4.90 N  
0.78 N  
1.6 mm  
Between terminals of  
same polarity  
1,000 VAC, 50/60 Hz for 1  
minute  
Between current-  
carrying metal part and  
ground, and between  
Contact Form  
Dielectric  
strength  
Name  
Contact form  
1,500 VAC, 50/60 Hz for 1  
each terminal and non- minute  
current-carrying metal  
part  
Double-throw contacts  
NC  
NO  
Vibration  
resistance  
10 to 55 Hz, 1.5 mm  
Malfunction  
double amplitude *  
COM  
Destruction  
Malfunction  
Mechanical  
Electrical  
500 m/s2  
Shock  
200 m/s2 max. *  
3,000,000 operations min.  
100,000 operations min.  
Approx. 12 to 40 g  
36 A max.  
resistance  
Approved Standard Ratings  
Durability  
Weight  
The built-in V-15-1A5 Switch is approved for UL and CSA.  
NC  
NO  
Inrush  
current  
36 A max.  
–25 to 80°C (with no icing or  
Ambient operating temperature  
Ambient operating humidity  
Ambient storage temperature  
condensation)  
35% to 85%RH  
–25 to 80°C (with no icing or  
condensation)  
Degree of protection  
Electric shock protection class  
PTI (proof tracking index)  
Pollution degree  
IP00  
Class II  
175  
3 (IEC947-5-1)  
* Malfunction within 1 ms  
Insert one of the following letters into the box (@) in the model number. Refer to Ordering Information for color symbols.  
Dimensions  
(Unit: mm)  
VAQ-4@-K  
3 × 16 tapping screw  
*4  
18  
11  
5.6 dia. 6 dia.  
Width across hexagonal nut flats: 14,  
*2  
*3  
Thickness: 2.  
15 dia. (lock washer)  
Face nut thickness: 2, Diameter: 14.  
*1  
38  
One, M10  
22.2  
3
28  
13 dia.  
11.4  
7
Note: The Operation Unit can be  
inserted and removed.  
8.6 10.3  
*1. Unthreaded screw section: Approx. one thread  
*2. Thermoplastic resin foam  
*3. V-15-1A5 Miniature Basic Switch  
*4. Three, #187 tab/solder terminals (t = 0.5)  
10  
21.9  
25  
FP: 24.5 max.  
2
VAQ  
VAQ-4@-L  
3 × 16 tapping screw  
*4  
18  
11  
5.6 dia. 6 dia.  
*2  
Width across hexagonal nut flats: 14,  
Thickness: 2.  
*3  
15 dia. (lock washer)  
Face nut thickness: 2, Diameter: 14.  
*1  
38  
One, M10  
22.2  
3
28  
13 dia.  
7
*1. Unthreaded screw section: Approx. one thread  
*2. Thermoplastic resin foam  
*3. V-15-1A5 Miniature Basic Switch  
*4. Three, #187 tab/solder terminals (t = 0.5)  
11.4  
8.6 10.3  
Note: The Operation Unit is  
mounted with M3 screws.  
10  
FP: 24.5 max.  
21.9  
25  
VAQR-4@  
24.5  
16 max.  
6.2  
2
*4  
Two, M3 × 16 pan-head mounting screws  
25  
*2 *3  
Width across hexagonal nut flats: 14,  
Thickness: 2.  
15 dia. (lock washer)  
Face nut thickness: 2, Diameter: 14.  
*1  
38  
38  
One, M10  
22.2  
3
28  
13 dia.  
5.5  
*1. Unthreaded screw section: Approx. one thread  
*2. V-15-1A5 Miniature Basic Switch  
*3. Separator (t = 0.18 mm) (varnished Tetron cloth)  
*4. Six, #187 tab/solder terminals (t = 0.5)  
Note: The Operation Unit is  
mounted with M3 screws.  
1.8  
11.4  
10 7.1 10.3  
21.3  
FP: 24.5 max.  
29  
2VAQ-4@  
*4  
2.7  
25.3  
2
*3  
*2  
Two, M3 × 28 tapping screw  
Width across hexagonal nut flats: 14,  
Thickness: 2.  
15 dia. (lock washer)  
Face nut thickness: 2, Diameter: 14.  
*1  
39  
38  
One, M10  
22.2  
29.2  
13 dia.  
6
4
*1. Unthreaded screw section: Approx. one thread  
*2. Two V-15-1A5 Miniature Basic Switches  
*3. Separator (t = 0.18 mm) (varnished Tetron cloth)  
*4. Six, #187 tab/solder terminals (t = 0.5)  
Note: The Operation Unit is  
mounted with M3 screws.  
8.1 10.3  
0.8  
11.4  
FP: 24.5 max.  
10  
21.4  
29  
Panel Cutout  
(Unit: mm)  
10.5 0.3 dia.  
Note: Recommended panel  
thickness: 1 to 4 mm.  
3
VAQ  
Safety Precautions  
Refer to Safety Precautions for All Pushbutton Switches.  
Precautions for Correct Use  
Operation Unit Mounting  
Panel Mounting and Operation Unit Mounting  
VAQ-4@-K  
Operation Unit Mounting  
VAQ-4@-K  
The Operation Unit can be inserted  
and removed.  
Mounting can be performed by  
The Operation Unit can be inserted and removed.  
Mounting can be performed by inserting the slit of the Operation  
Unit into the mounting screw of the Switch.  
Mounting force: 39.2 N max.  
Operation Unit  
Removing strength: 22.5 N min.  
inserting the slit of the Operation Unit  
Slit  
Insert/remove  
VAQ-4@-L  
The Operation Unit is screwed in.  
into the mounting screw of the Switch.  
Mounting force: 39.2 N max.  
Mounting screw  
Mounting can be performed by inserting the M3 screw of the  
Operation Unit into the flange of the Switch.  
Tighten the Operation Unit to a torque of 0.20 to 0.39 N·m.  
2VAQ-4@  
VAQR-4@  
The Operation Unit is screwed in.  
Mounting can be performed by inserting the M3 screw of the  
Operation Unit into the metal flange of the Switch.  
Tighten the Operation Unit to a torque of 0.20 to 0.39 N·m.  
Removing strength: 22.5 N min.  
VAQ-4@-L, 2VAQ-4@, VAQR-4@  
The Operation Unit is screwed in.  
Mounting can be performed by  
inserting the M3 screw of the  
Operation Unit into the flange of the  
Switch.  
Tighten the Operation Unit to a torque  
of 0.20 to 0.39 N·m.  
Screw-mounted  
Operation Unit  
M3 screws  
Flange  
Mounting  
Tighten the nut to a torque of 0.49 to 0.78 N·m.  
Do not perform wiring with power supplied to the Switch. Do not  
touch the terminals or other charged parts of the Switch while  
power is being supplied. Doing so may result in electric shock.  
After wiring the Switch, ensure an appropriate insulating distance.  
Panel Mounting  
Tighten the hexagonal nut using a wrench while securing the Switch  
by holding it with your fingers.  
(Hexagonal nut tightening torque: 0.98 N·m)  
Wiring  
Face nut  
Twist the conductors through the terminal holes before soldering.  
To perform soldering on solder terminals, use a soldering iron with  
a capacity of 60 W maximum and complete soldering within 5  
seconds. Wait for one minute after soldering before exerting any  
external force on the solder.  
Panel  
Lock washer  
For connection with tab terminals, gently insert receptacles for  
#187 tabs in the terminal push-out direction.  
The Switch does not have a ground terminal.  
Hexagonal nut  
Locking Method  
VAQR-@@  
To turn ON the lock, press the Operation Unit and turn it clockwise  
as indicated at the top of the Operation Unit.  
To release the lock, turn the Operation Unit counterclockwise.  
Operation Unit Models  
Method  
Insert/remove  
Screw-mounted  
Operation Unit color  
Blue (A)  
VAQ-BA HEAD  
VAQ-BB HEAD  
VAQ-BG HEAD  
VAQ-BR HEAD  
VAQ-BW HEAD  
VAQ-BY HEAD  
VAQ-4A YO HEAD  
VAQ-4B YO HEAD  
VAQ-4G YO HEAD  
VAQ-4R YO HEAD  
VAQ-4W YO HEAD  
VAQ-4Y YO HEAD  
Black (B)  
Green (G)  
Red (R)  
White (W)  
Yellow (Y)  
4
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2010.10  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2010 All Right Reserved.  

相关型号:

VAR

Ultra High Precision, High Resolution Z-Foil Audio Resistor, with TCR of ± 0.2 ppm/°C, Tolerance to ± 0.01 % and Noise < - 40 dB
VISHAY

VAR-18024053M3P-K

Ring Varistors
TDK

VAR-18030053M3P-AK

Ring Varistors
TDK

VAR-18030053M3P-K

Ring Varistors
TDK

VAR-18042032Y3P-K

Varistor, 4.5V, Surface Mount, LEAD FREE
TDK

VAR-18042053M3P-K

Varistor, 6.6V, Surface Mount, LEAD FREE
TDK

VAR-18042077M3P-K

Varistor, 9.4V, Surface Mount, LEAD FREE
TDK

VAR-18048032Y3P-K

Varistor, 4.5V, Surface Mount, LEAD FREE
TDK

VAR-18048053M3P-K

Varistor, 6.6V, Surface Mount, LEAD FREE
TDK

VAR-18048077M3P-K

Varistor, 9.4V, Surface Mount, LEAD FREE
TDK

VAR-18060032Y3P-K

Ring Varistors
TDK

VAR-18060053M3P-K

Ring Varistors
TDK