WLCA2-7TS-N [OMRON]
Snap Acting/Limit Switch,;型号: | WLCA2-7TS-N |
厂家: | OMRON ELECTRONICS LLC |
描述: | Snap Acting/Limit Switch, |
文件: | 总72页 (文件大小:15223K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Two-circuit Limit Switch
WL-N/WL
Two-circuit limit switches that can be
selected to match the operating
environment and application
• Wide variety of head shapes, including Roller Lever,
Plunger, Flexible Rod, and Fork Lock Lever Switches.
• You can select the optimum actuator shape for the
workpiece shape and movement from a variety of
actuators.
• In addition to general detection, we also have environment
resistant models for harsh environments, sputter resistant
models for welding processes, and long-life models for
high-frequency use.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on page 62 to 67
and Safety Precautions for All Limit Switches.
Features
General-purpose Switches
A Wide Range of Models
You can select the optimum product for the workpiece shape and
movement from a variety of actuators, including Roller Lever,
Plunger, Flexible Rod, and Fork Lock Lever Switches.
Features Common
DPDB Operation
The two-circuit double-break structure ensures circuit braking.
• Basic/Retention type Switches (WL-N)
11
12
14
13
Za
Environment-resistant Switches
(NO)14
(NC)11
13(NO)
12(NC)
Six environment resistant models are available
Airtight Switches, Hermetic Switches, Heat-resistant Switches, Low-
temperature Switches, Corrosion-proof Switches, and Weather-proof
Switches are available.
Load
Load
• High-sensitivity/High-precision Switches (WL)
You can select the model based on the onsite environment.
1
4
3
2
Spatter-prevention Switches
Ideal for Welding Sites
Uses stainless steel and plastic materials that prevent the adhesion
of spatter.
Za
(NO)4
(NC)1
3(NO)
2(NC)
Load
Load
They can be used to reduce problems caused by zinc power
generated during welding.
Degree of Protection; IP67
Long-life Switches
Models with Connectors to Reduce Wiring
Long-life Models for High-frequency
Applications
A mechanical durability of over 30 million cycles is achieved by
improving slidability and the wear resistance of the head.
A neon lamp or LED indicates the operating status. This makes
startup checks and maintenance easy.
Sensor I/O Connector Models to Match Wiring
Specifications
Direct-wire types and pre-wired types are available for easy
replacement of limit switches.
1
WL-N/WL
Product Configuration
Typical models
Head/Actuator
Operating Characteristic
WLC@-N
WLG@
WLGCA2
General-
purpose
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
High-precision Switches
Standard *1
WLD@-N
WLSD@-N
Plunger Actuators
Basic Switches
WLNJ-@-N
Flexible Rod Actuators
Fork Lock Lever Actuator
Basic Switches
WLCA32-4@-N
Retention type Switches
Indicator-equipped
WLC@-LE-N
WLG@-LE
WLGCA2-LE
Basic Switches
High-sensitivity Switches
High-precision Switches
Roller Lever
Actuators
Operation indicators *1
Switches:Neon lamps
Indicator-equipped
Switches: Light emitting
diodes (LED)
WLC@-LD-N
WLG@-LD
WLGCA2-LD
Basic Switches
High-sensitivity Switches
High-precision Switches
Basic Switches
Basic Switches
WLD@-LE-N
Plunger
Actuators
Indicator-equipped
WLSD@-LE-N
Switches: Neon lamps
Indicator-equipped
Switches: Light emitting
diodes (LED)
WLD@-LD-N
WLSD@-LD-N
Indicator-equipped
Basic Switches
Basic Switches
WLNJ-@LE-N
WLNJ-@LD-N
Flexible Rod
Actuators
Switches: Neon lamps
Indicator-equipped
Switches: Light emitting
diodes (LED)
Indicator-equipped
Retention type Switches
Retention type Switches
WLCA32-4@LE-N
WLCA32-4@LD-N
Fork Lock
Lever Actuator
Switches: Neon lamps
Indicator-equipped
Switches: Light emitting
diodes (LED)
Direct-wired Types
Pre-wired Types
WLCA2-LDK@-N
WLG2-LDK@
WLGCA2-LDK@
Sensor I/O connectors
Basic Switches
High-sensitivity Switches
Roller Lever
Actuators
High-precision Switches
WLCA2-@LD-M1@@-N
WLCA2-@LD-D@J-N
Basic Switches
High-sensitivity Switches
WLG2-@LD-M1@@
WLG2-@LD-D@J@
High-precision Switches
WLGCA2-@LD-M1@@
WLGCA2-@LD-D@J@
Basic Switches
Basic Switches
WLD28-@LDK@-N
WLD28-@LD-M1@@-N
WLD28-@LD-D@J-N
Direct-wired Types
Pre-wired Types
Plunger
Actuators
*1. The standard wiring specification is the Screw terminal type.
*2. Wiring specification: Smart-click type is also available.
2
WL-N/WL
Head/Actuator
Operating Characteristic
Typical models
Basic Switches
WLC@-55-N
WLG@-55
WLGCA2-55
Environment-
resistant
*1
Roller Lever Actuators
Airtight seal *4
High-sensitivity Switches
High-precision Switches
Basic Switches
WLD@-55-N, WLSD@-55-N
WLNJ-@55-N
Plunger Actuators
Basic Switches
Flexible Rod Actuators
Roller Lever Actuators
Basic Switches
WLC@-139-N
WLG@-139
WLGCA2-139
Hermetic seal *4
High-sensitivity Switches
High-precision Switches
WLD@-139-N, WLSD@-139-N
WLNJ-@139-N
Basic Switches
Plunger Actuators
Basic Switches
Flexible Rod Actuators
Basic Switches
WLC@-TH-N
WLG@-TH
WLGCA2-TH
Heat-resistant
Roller Lever Actuators
High-sensitivity Switches
High-precision Switches
Basic Switches
WLD@-TH-N, WLSD@-TH-N
WLNJ-@TH-N
Plunger Actuators
Basic Switches
Flexible Rod Actuators
Basic Switches
High-sensitivity Switches
High-precision Switches
WLC@-TC-N
WLG@-TC
WLGCA2-TC
Low-temperature
Roller Lever Actuators
Basic Switches
WLD@-TC-N, WLSD@-TC-N
WLNJ-@TC-N
Plunger Actuators
Basic Switches
Flexible Rod Actuators
Roller Lever Actuators
Basic Switches
High-sensitivity Switches
WLC@-RP-N
WLG@-RP
Corrosion-proof
High-precision Switches
WLGCA2-RP
Basic Switches
WLD@-RP-N, WLSD@-RP-N
Plunger Actuators
Basic Switches
WLNJ-@RP-N
Flexible Rod Actuators
Basic Switches
WLC@-P1-N
WLG@-P1
Weather-proof
Roller Lever Actuators
High-sensitivity Switches
Basic Switches
WLCA2-@S-N
WLG2-@S
WLGCA2-@S
WLD28-@S-N
Spatter-prevention *1 *3
Roller Lever Actuators
Plunger Actuators
High-sensitivity Switches
High-precision Switches
Basic Switches
Basic Switches
High-sensitivity Switches
High-precision Switches
WLMCA2-@-N
WLMG2-@
WLMGCA2-@
Roller Lever Actuators *4
Long-life *1 *2 *3
*1. The standard wiring specification is the Screw terminal type.
*2. Wiring specification: Direct-wire Connector type is also available. Contact your OMRON sales representative for further information.
*3. Wiring specification: Pre-wired Connector type is also available. Contact your OMRON sales representative for further information.
*4. A type with an operation indicator light is also available. For details, see Ordering Information.
3
WL-N/WL
Selection
WL-N/WL Actuator Types and Selection
Shock and
vibration
resistance *1
Operating
force (OF) accuracy *1
Repeat
Head
Appearance
Classification
Description
• Can be used over a wide range, from positioning to
workpiece detection.
• Easy to use because the stroke in the direction of revolution
can be set to an angle from 45° to 90° (varies by model),
and the lever can be set to any angle over 360°.
• High-sensitivity Switches with minimal movement before
activation (example: WLG2) and High-precision Switches
with high repeatability (example: WLGCA2) are available.
★★★
Medium
Roller Lever
★★★
★★ *2
Roller Lever
Models
• Adjustable length between dog and lever. (Consideration
must be given to telegraphing.)
Adjustable
Roller Lever
• Can be used over a wide range, from positioning to
workpiece detection.
• High-sensitivity Switches with minimal movement before
activation (example: WLG12) are also available.
Medium
Medium
★★
★★
• Suitable for detection of a dog or workpiece with a large
amount of play. (Consideration must be given to
telegraphing.)
• Also good for detection of irregularly shaped workpieces.
• Lightest activation (WLCL-N) among rotating-type limit
switches.
Adjustable Rod
Lever
★★
★★
• Rod length is adjustable.
• High-sensitivity Switches with minimal movement before
activation (example: WLG2) are also available.
• High repeatability, good for positioning detection.
• The workpiece movement direction and plunger movement
direction must be matched so that an unbalanced load is not
applied to the plunger.
Plunger
Large
Large
Large
Small
★★★
★★★
★★
★★★
★★★
★★★
★
Plunger Models
• A wide range of operation is possible by attaching an
auxiliary actuator to a cam, dog, cylinder, or other part.
• High repeatability, good for positioning detection.
Roller plunger
Ball plunger
Coil spring
• The tip of the plunger is made of a steel ball, which can be
operated in any direction with no limitations.
• The ball plunger is convenient when the mounting side is not
aligned with the movement direction of the dog or the Limit
Switch is actuated by two dogs in X and Y directions.
• Operation from any direction over 360° is possible,
excluding the axial direction.
• Lowest activation force of the limit switches. Effective for
detection of non-uniform directions and shapes.
• Large tolerance for workpiece play because the actuator
absorbs movement after activation.
★
Flexible rod
Models
• The resin rod minimizes damage to the workpiece.
• Operation from any direction over 360° is possible,
excluding the axial direction.
• Lowest activation force of the limit switches. Effective for
detection of non-uniform directions and shapes.
• Large tolerance for workpiece play because the actuator
absorbs movement after activation.
Resin rod
Small
★
★
• The steel wire enables easy workpiece length adjustment,
and easy bending is possible.
• Operation from any direction over 360° is possible,
excluding the axial direction.
Steel wire
Small
★
★
• Lowest activation force of the limit switches. Effective for
detection of non-uniform directions and shapes.
• Large tolerance for workpiece play because the actuator
absorbs movement after activation.
Fork Lock Lever
Models
• Self-rotates when operated to a position of 55°, holds state
at the 90° position.
Fork Lock Lever
Medium
★★
★★★
• Reciprocating motion can be detected with a single dog.
• To allow greater deviation in the roller position, two dogs can
be used.
*1. Indications for repeat accuracy and shock and vibration resistance are as follows: ★: OK, ★★: Good, ★★★: Excellent
*2. The top line shows High-precision Switches. The bottom line shows Basic Switches.
4
WL-N/WL
OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for your application.
According to Operating Environment
Environment
Key specifications
Models
−10°C
+80°C
General-purpose
Switches
Standard model
High-sensitivity,
WL@-N
WLG@
Normal
High-precision model
Standard model
Long-life Switches
WLM@-N
WLMG@
Water-resistant to IP67.
High-sensitivity,
High-precision model
+120°C
+5°C
WL@-TH-N
WLG@-TH
Environment-resistant,
Heat-resistant Switches High-sensitivity,
Standard model *1
High-temperature
Low-temperature
To increase heat resistance, the rubber material have
been changed.
High-precision model *1
−40°C
+40°C
WL@-TC-N
WLG -TC
Standard model *1
High-sensitivity,
High-precision model *1
Environment-resistant,
Low-temperature Switches
@
To increase resistance to cold, epichlorhydrin rubber
and other measures are used.
A rubber material resistant to temperature changes is
used.
Stainless steel is used for the screws.
The roller is made of stainless steel with superior corrosion
resistance.
WL@-P1-N
WLG -P1
Standard model *1
High-sensitivity,
High-precision model *1
Environment-resistant,
Weather-proof Switches
@
Outdoors
Corrosion-proof specifications have been used for the
housing, fluorine rubber has been used for rubber
parts, and stainless steel has been used for screws
and nuts (except for the actuator) to increase
resistance to oils, chemicals, and weather.
WL@-RP-N
WLG -RP
Standard model *1
High-sensitivity,
High-precision model *1
Environment-resistant,
Corrosion-proof Switches
Chemicals and oil
@
WL@-55-N
WLG@-55
Standard model *1
High-sensitivity,
High-precision model *1
Environment-resistant,
Airtight Switches
Water drops and mist
Uses an airtight built-in switch.
Cables are attached. Uses a general-purpose built-in
switch.
The cover screws, case cover, and conduit opening are
molded from epoxy resin to increase the seal. (The
cover cannot be removed.)
WL@-139-N
WLG@-139
Standard model *1*2
High-sensitivity,
High-precision model *1*2
Environment-resistant,
Molded-terminal Switches
Cables are attached. Uses an airtight built-in switch.
The case cover and conduit opening are molded from
epoxy resin to increase the seal. (The cover cannot be
removed.)
The SC connector can be removed, so it is possible to
use flexible conduit for the cable.
Constant water
drops and mist
WL@-RP40-N
WLG@-RP40
Standard model *1*2
High-sensitivity,
High-precision model *1*2
Environment-resistant,
Molded-terminal Switches
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are
molded from epoxy resin to increase the seal. (The cover
cannot be removed.)
WL@-140-N
WLG@-140
Standard model *1*2
High-sensitivity,
High-precision model *1*2
Environment-resistant,
Molded-terminal Switches
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, and conduit opening are
molded from epoxy resin to increase the seal. (The
cover cannot be removed.)
Two-layer seal on actuator rotation shaft.
-141: The Head section is molded from epoxy resin;
Head direction cannot be changed.
WL@-141-N
WLG@-141
Standard model *1*2
High-sensitivity,
Environment-resistant,
Molded-terminal Switches
Constant water
drops or splattering
cutting powder
High-precision model *1*2
WL@-145-N
WLG@-145
Environment-resistant,
Molded-terminal Switches
Standard model *1*2
High-sensitivity,
High-precision model *1*2
-145: The Head section is molded from epoxy resin;
Head can be in any of 4 directions.
Cables are attached. Uses an airtight built-in switch.
The cover screws, case cover, conduit opening, and
head screws are molded from epoxy resin to increase
the seal.
(The cover and head cannot be removed.)
Rubber parts are made from fluorine rubber to
increase resistance to coolant.
WL@-RP60-N
WLG@-RP60
Environment-resistant,
Anti-coolant Switches
Standard model *1*2
High-sensitivity,
High-precision model *1*2
Coolant
To prevent spatter during welding, a heat-resistant
resin is used for the indicator cover and screws and
rollers are all made from stainless steel.
Spatter-prevention
Switches
Standard model
High-sensitivity,
High-precision model
WL@-@S-N
WLG2-@S
WLGCA2-@S
Spattering from
welding
*1. Not all functions can be combined with environment-resistant models.
*2. For details on the hermetic structure, see the hermetic mold specifications on pages 40 and 41.
5
WL-N/WL
According to Application Conditions
Conditions
Key specifications
Models
General-purpose Switches
Environment-resistant Switches Basic Switches
Spatter-prevention Switches
Long-life Switches
Basic/Retention type Switches
WL@-@-N
Applicable to either standard
loads or microloads.
Basic Switches
Basic Switches
10 A at 125,250, or 500 VAC
0.8 A at 125 VDC
0.4 A at 250 VDC
Switching
standard
loads
General-purpose Switches
Environment-resistant Switches
Spatter-prevention Switches
Long-life Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
WL
WLG@
WLG@-S
WLMG@
General-purpose Switches
Basic/Retention type Switches
WL@-@-N
Applicable to either standard
loads or microloads.
0.1 A at 125 VAC,
resistive load
Switching
microloads
0.1 A at 30 VDC,
resistive load
General-purpose
High-sensitivity/High-precision Switches
WL
Microload Switches
WL01G@
General-purpose Switches
Spatter-prevention Switches
Basic Switches
Basic Switches
WL@-N
Mechanical: 15 million
operation min.
(10 million operation min. for
high-sensitivity models * or
flexible rod models)
WL@-S-N
Normal
durability
General-purpose Switches
Spatter-prevention Switches
High-sensitivity/High-precision Switches
High-sensitivity/High-precision Switches
WL
WLG@
WLG@-S
Long-life Switches
Long-life Switches
Basic Switches
WLM@-N
Mechanical: 30 million
operation min.
Long-life
High-sensitivity/
High-precision Switches
WL
WLMG@
According to Ease of Installation and Maintenance
Conditions
Key specifications
Models
Neon lamp
125 to 250 VAC
Switching light-ON between
operating/not operating.
(Switching is not possible for
Switches with Molded Terminals.)
General-purpose,
Basic Switches
High-sensitivity/High-precision Switches
WL@-LE-N
WLG@-LE
Indicator-equipped Switches
Daily
Spatter-prevention Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-LES-N
WLG@-LES
inspections
and
maintenance
checks
LED
General-purpose,
Basic Switches
High-sensitivity/High-precision Switches
WL@-LD-N
WLG@-LD
Indicator-equipped Switches
10 to 115 VAC/DC
Switching light-ON between
operating/not operating.
(Switching not possible for
models with molded terminals.)
Spatter-prevention Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-LDS-N
WLG@-LDS
General-purpose Switches
Long-life Switches
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-N
WLG@
WLM@-N
WLMG@
Screw terminals. No ground terminal.
Conduit size: G1/2
Screw
tightening
and
installation
Screw terminals. Ground terminal.
Conduit size: 4 sizes
General-purpose Switches
General-purpose Switches
Long-life Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-N
WLG@
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LDK13@-N
WLG@-@LDK13@
WLM@-LDK13@-N
WLMG@-@LDK13@
Direct-wired connector, 2-conductor.
Greatly reduces wiring work.
Basic Switches
High-sensitivity/High-precision Switches
One-touch
connector
attachment
General-purpose Switches
Long-life Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LDK43@-N
WLG@-@LDK43@
Direct-wired connector, 4-conductor.
Greatly reduces wiring work.
Basic Switches
High-sensitivity/High-precision Switches
WLM@-LDK43@-N
WLMG@-@LDK43@
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LD-M1@J-N
WLG@-@LD-M1@J
WL@-@S-M1@J-1-N
WLG@-@S-M1@J-1
WLM@-LD-M1@J-N
WLMG@-LD-M1@J
Pre-wired connector, 2-conductor.
Greatly reduces wiring work.
Smartclick connectors for even
easier maintenance.
Basic Switches
High-sensitivity/High-precision Switches
Connector
attachment
in control
and relay
boxes
Basic Switches
High-sensitivity/High-precision Switches
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
Basic Switches
High-sensitivity/High-precision Switches
WL@-@LD-@GJ-N
WLG@-@LD-@GJ@
WL@-@S-@GJS-N
WLG@-@S-@GJS@
WLM@-LD-@GJ-N
WLMG@-LD-@GJ@
Pre-wired connector, 4-conductor.
Greatly reduces wiring work.
Smartclick connectors for even
easier maintenance.
Basic Switches
High-sensitivity/High-precision Switches
Basic Switches
High-sensitivity/High-precision Switches
6
WL-N/WL
Application Examples
Detection of Passing Pallets on Production
Lines
Detection of Work Table Origins (X, Y, and Z)
on Machine Tools
Detection of Forward and Reverse Movement
of Hydraulic Cylinders on Molding Machines
Detection of Arm Movement on Welding
Robots
Detection of Car Pallet Positions in Parking
Towers
Detection of Vertical Limits on Conveyor
Systems
7
WL-N/WL
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
Standard Switches
Operation indicator Switches
Basic and Retention type Switches
WL@ - @ @ @ @ -N
(1) (2) (3) (4) (5)
(1) Actuator and Property Specifications
(2) Built-in Switch Specifications
Code
CA2
Actuator
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
Roller lever: R38 mm
Roller lever: R50 mm
Roller lever: R63 mm
CA2-7
CA2-8
CA12
CL
Adjustable roller lever: R25 to 89 mm
Adjustable rod lever: 25 to 140 mm
Adjustable rod lever: 350 to 380 mm
Rod spring lever
(3) Conduit Size, Ground Terminal Specifications
Specifications
Code
CAL4
CAL5
CA2-2
CA12-2
CL-2
Conduit Size
Ground terminal
Blank
G1
G
G1/2
None
Roller lever: R38 mm
G1/2
Adjustable roller lever: R25 to 89 mm
Adjustable rod lever: 25 to 140 mm
Roller lever: R38 mm
Pg13.5
M20
1/2-14NPT
Provided *
Y
CA2-2N
CA12-2N
CL-2N
CA32-41
CA32-42
CA32-43
D18
TS
Adjustable roller lever: R25 to 89 mm
Adjustable rod lever: 25 to 140 mm
Fork lock lever
* Models with ground terminals are certified for EN/IEC (CE Marking).
(4) Indicator Specifications
Fork lock lever
Fork lock lever
Code
Blank
LE
Specifications
No indicator
Sealed top plunger
D28
Sealed top-roller plunger
Sealed top-ball plunger
Top-roller plunger
Neon lamp: 125 to 250 VAC
LED (10 to 115 VAC/DC)
D38
LD
D2
SD
Horizontal plunger
(5) Lever Specifications
SD2
Horizontal-roller plunger
Horizontal-ball plunger
Code
Blank
A
Specifications
SD3
Standard lever (Allen-head bolt)
Double nut lever
NJ
Flexible rod: Coil spring
Flexible rod: Coil spring, multi-wire
Flexible rod: Resin rod
NJ-30
NJ-2
NJ-S2
Flexible rod: Steel wire
8
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
Standard Switches
Operation indicator Switches
High-sensitivity and High-precision Switches
WL@ @ - @ @ @ @ @ @ @ @
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
(1) Electrical Rating
Code
Blank
01
Specifications
Standard load
Microload
(2) Actuator and Property Specifications
Code
G2
Actuator
Roller lever: R38 mm High-sensitivity
GCA2
G12
GL
Roller lever: R38 mm High-precision
Adjustable roller lever: R25 to 89 mm High-sensitivity
Adjustable roller lever: 25 to 140 mm High-sensitivity
(3) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(4) Conduit Size, Ground Terminal Specifications
Specifications
Code
Conduit Size
Ground terminal
Blank
G1
G
G1/2
None
G1/2
Pg13.5
M20
Provided *
Y
TS
1/2-14NPT
* Models with ground terminals are certified for EN/IEC (CE Marking).
(5) Indicator Type
Code
Blank
LE
Specifications
No indicator
Neon lamp: 125 to 250 VAC
LED (10 to 115 VAC/DC)
LD
(6) Lever Type
Code
Blank
A
Specifications
Standard lever (Allen-head bolt)
Double nut lever
9
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
Basic and Retention type Switches
Sensor I/O Connector Switches
WL@ - @ L D @ -N
(1) (2) (3) (4)
(1) Actuator and Property Specifications
Code
CA2
D28
D2
Actuator
Roller lever: R38 mm
Sealed top-roller plunger
Top-roller plunger
(2) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(3) Indicator Specifications
Code
Specifications
LED (10 to 115 VAC/DC)
LD
(4) Connector Type Wiring Specifications
Specifications
Code
Shape
Voltage *1
AC
Wiring locations
Connector pin No. *2
3
3
1
1
3
1
3
1
1
2
3
1
3
1
2
4
K13A
K13
NO only
NO only
NC+NO
NC+NO
NO only
NO only
NC only
NC+NO
NC+NO
NO only
NO only
NO only
NC only
NC+NO
NO only
NO:
NO:
NC:
NC:
NO:
NO:
NC:
NC:
NC:
NC:
NO:
NO:
NC:
NC:
NC:
4
DC
Direct-wire Connector type
Threaded (M12)
2
3
3
4
4
K43A
K43
AC
, NO:
, NO:
2
DC
4
-M1J
DC
4
-M1GJ
-M1JB
-AGJ
DC
2
DC
Threaded (M12)
2
3
3
4
4
4
AC
, NO:
, NO:
2
-DGJ
DC
Pre-wired Connector type
*3
3
-DK1EJ
-M1TJ
-M1TGJ
-M1TJB
-DTGJ
-DTK1EJ
DC
, NO:
4
4
2
DC
DC
Smartclick
DC
2
3
4
4
DC
, NO:
3
DC
, NO:
*1. DC models are certified for EN/IEC (CE Marking).
*2. Refer to Contact Forms on page 21 for details on connector pin numbers.
*3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
10
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose Switches
High-sensitivity and High-precision Switches
Sensor I/O Connector Switches
WL@ @ - @ L D @ -N
(1) (2) (3) (4) (5)
(1) Electrical Rating
Code
Blank
01
Specifications
Standard load
Microload
(2) Actuator and Property Specifications
Code
G2
Actuator
Roller lever: R38 mm High-sensitivity
Roller lever: R38 mm High-precision
GCA2
(3) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(4) Indicator Specifications
Code
Specifications
LED (10 to 115 VAC/DC)
LD
(5) Connector Type Wiring Specifications
Specifications
Code
Shape
Voltage *1
AC
Wiring locations
NO only
NO only
NC+NO
Connector pin No. *2
3
3
1
1
3
1
3
1
1
2
4
K13A
NO:
NO:
NC:
NC:
NO:
NO:
NC:
NC:
NC:
NC:
4
K13
DC
Direct-wire Connector type
2
3
3
4
4
K43A
AC
, NO:
, NO:
2
K43
DC
NC+NO
4
-M1J *1
DC
NO only
NO only
NC only
Threaded (M12)
4
-M1GJ *1
-M1JB
DC
2
2
DC
Pre-wired Connector type *3
3
3
4
4
4
-AGJ03
AC
NC+NO
, NO:
, NO:
2
-DGJ03 *1
-DK1EJ03 *1
DC
NC+NO
3
DC
NO only
, NO:
*1. DC models are certified for EN/IEC (CE Marking).
*2. Refer to Contact Forms on page 21 for details on connector pin numbers.
*3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
11
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic Switches
Environment-resistant Switches
WL@ - @ @ @ @ @ @ @ @ -N
(1) (2) (3) (4) (5) (6) (7) (8) (9)
(1) Actuator and Property Specifications
(5) Hermetic Specifications
Code
CA2
Actuator
Code
Blank
Specifications
Roller lever: R38 mm
Roller lever: R50 mm
Roller lever: R63 mm
No cable molding.
CA2-7
CA2-8
CA12
CL
Standard built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
139
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed.)
Adjustable roller lever: R25 to 89 mm
Adjustable rod lever: 25 to 140 mm
Adjustable rod lever: 350 to 380 mm
Rod spring lever
140
CAL4
CAL5
CA2-2
CA12-2
CL-2
Conduit opening, cover, head, cover attachment screw part, air-
tight built-in switch.
Cable is attached.
141
Roller lever: R38 mm
Molded head screws. (The cover cannot be removed and the
head direction cannot be changed.)
Two-layer seal on actuator rotation shaft.
Adjustable roller lever: R25 to 89 mm
Adjustable rod lever: 25 to 140 mm
Roller lever: R38 mm
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws.
(The cover cannot be removed. The head can be mounted in
any of 4 directions.)
CA2-2N
145
CA12-2N Adjustable roller lever: R25 to 89 mm
CL-2N Adjustable rod lever: 25 to 140 mm
Two-layer seal on actuator rotation shaft.
CA32-41 Fork lock lever
CA32-42 Fork lock lever
CA32-43 Fork lock lever
Airtight built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
SC Connector can be removed, so it is possible to use flexible
conduits for the cable.
RP40
RP60
D18
D28
D38
D2
Sealed top plunger
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, cover screws, and head screws.
(The cover cannot be removed and the head direction cannot
be changed.)
Sealed top-roller plunger
Sealed top-ball plunger
Top-roller plunger
Fluorine rubber is used for all rubber parts.
SD
Horizontal plunger
SD2
SD3
NJ
Horizontal-roller plunger
Horizontal-ball plunger
Flexible rod: Coil spring
Flexible rod: Coil spring, multi-wire
Flexible rod: Resin rod
Flexible rod: Steel wire
(6) Conduit Size, Ground Terminal Specifications
Specifications
Code
Conduit Size
Ground terminal
NJ-30
NJ-2
NJ-S2
Blank
G1
G
G1/2
None
G1/2
Pg13.5
M20
Provided *2
(2) Environment-resistant Model Specifications
Y
TS
1/2-14NPT
Code
Blank
RP
Specifications
*2. Models with ground terminals are certified for EN/IEC (CE
Marking).
Standard
Corrosion-proof
Weather-resistant
P1
(7) Indicator Specifications
(3) Built-in Switch Specifications
Code
Blank
LE
Specifications
No indicator
Code
Blank
55
Specifications
Neon lamp: 125 to 250 VAC *3
LED (10 to 115 VAC/DC) *3
Standard built-in switch
Airtight built-in switch
LD
*3. Cannot be combined with Corrosion-proof (RP), Weather-proof
(P1), Heat-resistant (TC), or Low-temperature (TC) Switches.
(4) Temperature Specifications
Code
Blank
TH
Specifications
(8) Indicator Wiring Specifications
Standard: -10 to +80°C
Code
Specifications
Heat-resistant: -5 to +120°C *1
Low-temperature: -40 to +40°C *1
2
3
NC connection: Light-ON when operating *4
NO connection: Light-ON when not operating *4
TC
*1. Cannot be combined with Corrosion-proof (RP) or Weather-proof
(P1) Switches.
*4. Always include the indicator wiring specification if you specify a
(5) hermetic structure and an (7) indicator.
(9) Lever Type
Code
Blank
A
Specifications
Standard lever (Allen-head bolt)
Double nut lever
12
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
High-sensitivity and High-precision Switches
Environment-resistant Switches
WL@ @ - @ @ @ @ @ @ @ @
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
(1) Electrical Rating
(6) Hermetic Specification
Code
Blank
01
Specifications
Code
Blank
Specifications
Standard load
Microload
No cable molding.
Standard built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
139
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws. (The cover
cannot be removed.)
(2) Actuator and Property Specifications
140
Code
G2
Actuator
Conduit opening, cover, head, cover attachment screw part, air-
tight built-in switch.
Roller lever: R38 mm High sensitivity
Cable is attached.
Molded head screws. (The cover cannot be removed and the
head direction cannot be changed.)
GCA2
G12
GL
Roller lever: R38 mm High-precision
141
Adjustable roller lever: R25 to 89 mm High sensitivity
Adjustable rod lever: 25 to 140 mm High sensitivity
Two-layer seal on actuator rotation shaft.
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, and cover screws.
(The cover cannot be removed. The head can be mounted in
any of 4 directions.)
(3) Environment-resistant Model Specifications
145
Code
Blank
RP
Specifications
Two-layer seal on actuator rotation shaft.
Standard
Airtight built-in switch. Cable is attached.
Molded conduit opening and cover. (The cover cannot be removed.)
SC Connector can be removed, so it is possible to use flexible
conduits for the cable.
Corrosion-proof
Weather-proof
RP40
RP60
P1
Airtight built-in switch. Cable is attached.
Molded conduit opening, cover, cover screws, and head screws.
(The cover cannot be removed and the head direction cannot
be changed.)
(4) Built-in Switch Specifications
Code
Blank
55
Specifications
Fluorine rubber is used for all rubber parts.
Standard built-in switch
Airtight built-in switch
(7) Conduit Size, Ground Terminal Specifications
Specifications
Code
(5) Temperature Specifications
Conduit Size
Ground terminal
Code
Blank
TH
Specifications
Blank
G1
G
G1/2
None
Standard: -10 to +80°C
G1/2
Heat-resistant: -5 to +120°C *1
Low-temperature: -40 to +40°C *1
Pg13.5
M20
Provided *2
TC
Y
TS
1/2-14NPT
*1. Cannot be combined with Corrosion-proof (RP) or Weather-proof
(P1) Switches.
*2. Models with ground terminals are certified for EN/IEC (CE
Marking).
(8) Indicator Type
Code
Blank
LE
Specifications
No indicator
Neon lamp: 125 to 250 VAC *3
LED (10 to 115 VAC/DC) *3
LD
*3. Cannot be combined with Corrosion-proof (RP), Weather-proof
(P1), Heat-resistant (TC), or Low-temperature (TC) Switches.
(9) Indicator Wiring Specification
Code
Specifications
2
3
NC connection: Light-ON when operating *4
NO connection: Light-ON when not operating *4
*4. Always include the indicator wiring specification if you specify a
(6) hermetic structure and an (8) indicator.
(10) Lever Type
Code
Blank
A
Specifications
Standard lever (Allen-head bolt)
Double nut lever
13
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic Switches
Spatter-prevention Switches
WL@ - @ @ S@ -N
(1) (2) (3) (4)
(1) Actuator and Property Specifications
(3) Indicator Specifications
Code
CA2
D28
Actuator
Code
Specifications
Neon lamp: 125 to 250 VAC *1
LED (10 to 115 VAC/DC)
Roller lever: R38 mm
LE
LD
Sealed top-roller plunger
*1. Cannot be combined with a (4) Connector Type Wiring
Specifications.
(2) Built-in Switch Specifications
Code
Blank
55
Specifications
Standard built-in switch
Airtight built-in switch
(4) Connector Type Wiring Specifications
Specifications
Code
Shape
Voltage *2
Wiring locations
---
Connector pin No. *3
Blank
-M1J-1
-M1GJ-1
-DGJS
Screw terminal type
---
---
3
1
1
1
4
4
2
2
DC
DC
DC
DC
NO only
NO only
NC+NO
NC+NO
NO:
NO:
NC:
NC:
Threaded (M12)
Smartclick
Pre-wired Connector type
*4
3
3
4
4
, NO:
, NO:
-DTGJS
*2. DC models are certified for EN/IEC (CE Marking).
*3. Refer to Contact Forms on page 21 for details on connector pin numbers.
*4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
High-sensitivity and High-precision Switches
Spatter-prevention Switches
WL@ @ - @ @ S@
(1) (2) (3) (4) (5)
(1) Electrical Rating
(3) Built-in Switch Specifications
Code
Blank
01
Specifications
Code
Blank
55
Specifications
Standard load
Microload
Standard built-in switch
Airtight built-in switch
(2) Actuator and Property Specifications
(4) Indicator Specifications
Code
Blank
GCA2
Actuator
Roller lever: R38 High-sensitivity
Roller lever: R38 High-precision
Code
Specifications
LE
LD
Neon lamp: 125 to 250 VAC *1
LED (10 to 115 VAC/DC)
*1. Cannot be combined with a (5) Connector Type Wiring
Specifications.
(5) Connector Type Wiring Specifications
Specifications
Code
Shape
Voltage *2
Wiring locations
---
Connector pin No. *3
Blank
Screw terminal type
---
---
3
1
1
4
4
2
-M1J -1
DC
DC
DC
NO only
NO only
NC+NO
NO:
NO:
NC:
Pre-wired Connector type
*4
-M1GJ -1
-DGJS03
Threaded (M12)
3
4
, NO:
*2. DC models are certified for EN/IEC (CE Marking).
*3. Refer to Contact Forms on page 21 for details on connector pin numbers.
*4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
14
WL-N/WL
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Basic Switches
Long-life Switches
WLM@ - LD@ -N
(1) (2) (3)
(1) Actuator and Property Specifications
Code
CA2
Actuator
Roller lever: R38 mm
(2) Indicator Type
Code
Specifications
LD
LED (10 to 115 VAC/DC)
(3) Connector Type Wiring Specifications
Specifications
Code
Shape
Voltage
---
Wiring locations
---
Connector pin No. *1
Blank
K13A
K13
Screw terminal type
---
3
3
1
1
3
1
1
3
1
4
4
2
2
4
2
2
4
2
AC
NO only
NO only
NC+NO
NC+NO
NO only
NC+NO
NC+NO
NO only
NC+NO
NO:
NO:
NC:
NC:
NO:
NC:
NC:
NO:
NC:
DC
AC
Direct-wire Connector type
Threaded (M12)
3
3
4
4
K43A
K43
, NO:
, NO:
DC
DC
AC
-M1J
-AGJ
-DGJ
-M1TJ
-DTGJ
3
3
4
4
Threaded (M12)
Smartclick
, NO:
, NO:
Pre-wired Connector type *2
DC
DC
DC
3
4
, NO:
*1. Refer to Contact Forms on page 21 for details on connector pin numbers.
*2. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
High-sensitivity and High-precision Switches
Long-life Switches
WLM@ - LD@
(1) (2) (3)
(1) Actuator and Property Specifications
Code
G2
Actuator
Roller lever: R38 mm High-sensitivity
Roller lever: R38 mm High-precision
GCA2
(2) Indicator Type
Code
Specifications
LED (10 to 115 VAC/DC)
LD
(3) Connector Type Wiring Specifications
Specifications
Voltage
Code
Wiring loca-
tions
Shape
Connector pin No. *1
Blank
K13A
K13
Screw terminal type
---
---
---
3
3
1
1
3
1
1
4
4
2
2
4
2
2
AC
DC
AC
DC
DC
AC
DC
NO only
NO only
NC+NO
NC+NO
NO only
NC+NO
NC+NO
NO:
NO:
NC:
NC:
NO:
NC:
NC:
Direct-wire Connector type
3
3
4
4
K43A
K43
, NO:
, NO:
Threaded (M12)
-M1J
3
3
4
4
-AGJ03
-DGJ03
Pre-wired Connector type *2
, NO:
, NO:
*1. Refer to Contact Forms on page 21 for details on connector pin numbers.
*2. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths.
15
WL-N/WL
Ordering Information
General-purpose Switches
Standard Switches
Switches with Roller Lever Actuators
Basic Switches
Actuator
Roller lever: R38
Roller lever: R50
Roller lever: R63
Pretravel (PT)
15 5ꢀ
Model
WLCA2-N
Model
WLCA2-7-N
Model
WLCA2-8-N
25 5ꢀ
WLCA2-2-N
WLCA2-2N-N
---
---
---
---
20ꢀ max.
Actuator
Adjustable rod lever:
25 to 140 mm
Adjustable rod lever:
350 to 380 mm
Adjustable roller lever
Rod spring lever
Pretravel (PT)
15 5ꢀ
Model
WLCA12-N
Model
WLCL-N
Model
Model
WLCAL4-N
WLCAL5-N
25 5ꢀ
WLCA12-2-N
WLCA12-2N-N
WLCL-2-N
---
---
---
---
20ꢀ max.
WLCL-2N-N
High-sensitivity Switches
Actuator
Adjustable rod lever:
25 to 140 mm
Roller lever: R38
Adjustable roller lever
Load
Model
Model
WLG12
Model
WLGL
Standard load
Microload
WLG2
WL01G2
WL01G12
WL01GL
High-precision Switches
Actuator
Roller lever: R38
Load
Model
WLGCA2
Standard load
Microload
WL01GCA2
Switches with Plunger Actuators
Basic Switches
Actuator
Sealed Top-roller
plunger
Sealed Top Plunger
Sealed Top-ball plunger
Top-roller plunger
Pretravel (PT)
1.7 mm max.
Model
WLD18-N
Model
Model
Model
WLD28-N
WLD38-N
WLD2-N
Actuator
Horizontal plunger
Horizontal-roller plunger
Horizontal-ball plunger
Pretravel (PT)
2.8 mm max.
Model
Model
Model
WLSD-N
WLSD2-N
WLSD3-N
Switches with Flexible Rod Actuators
Basic Switches
Actuator
Coil spring
Coil spring
(spring diameter: 6.5)
(spring diameter: 4.8)
Pretravel (PT)
20 10 mm
Model
Model
WLNJ-N
WLNJ-30-N
Actuator
Resin rod
Steel wire
(rod diameter: 8)
(wire diameter: 1)
Pretravel (PT)
40 20 mm
Model
WLNJ-2-N
WLNJ-S2-N
Switches with Fork Lock Lever Actuator
Retention type Switches
Actuator
Fork lock lever
Fork lock lever
Fork lock lever
Fork lock lever
Pretravel (PT)
55ꢀ max.
Model
Model
Model
Model
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-44-N
16
WL-N/WL
General-purpose Switches
Operation indicator Switches
Switches with Roller Lever Actuators
Basic Switches
Actuator
Roller lever: R38
Roller lever: R50
Roller lever: R63
Indicator *
Neon lamp
Pretravel (PT)
15±5°
Model
WLCA2-LE-N
Model
Model
WLCA2-7LE-N
WLCA2-8LE-N
25±5°
WLCA2-2LE-N
WLCA2-2NLE-N
WLCA2-LD-N
WLCA2-2LD-N
WLCA2-2NLD-N
---
---
20° max.
15±5°
---
---
WLCA2-7LD-N
WLCA2-8LD-N
LED
25±5°
---
---
---
---
20° max.
Actuator
Adjustable rod lever:
25 to 140 mm
Adjustable rod lever:
350 to 380 mm
Adjustable roller lever
Rod Spring Lever
Indicator *
Neon lamp
Pretravel (PT)
15±5°
Model
WLCA12-LE-N
WLCA12-2LE-N
WLCA12-2NLE-N
WLCA12-LD-N
WLCA12-2LD-N
WLCA12-2NLD-N
Model
WLCL-LE-N
Model
Model
WLCAL4-LE-N
WLCAL5-LE-N
25±5°
WLCL-2LE-N
WLCL-2NLE-N
WLCL-LD-N
---
---
20° max.
15±5°
---
---
WLCAL4-LD-N
WLCAL5-LD-N
LED
25±5°
WLCL-2LD-N
WLCL-2NLD-N
---
---
---
---
20° max.
High-sensitivity Switches
Actuator
Roller lever R38
Indicator *
Neon lamp
LED
Pretravel (PT)
Model
WLG2-LE
+2°
10°
-1°
WLG2-LD
Actuator
Adjustable rod lever:
25 to 140 mm
Adjustable roller lever
Indicator *
Neon lamp
LED
Pretravel (PT)
Model
WLG12-LE
Model
WLGL-LE
+2°
10°
-1°
WLG12-LD
WLGL-LD
High-precision Switches
Actuator
Roller lever R38
Indicator *
Neon lamp
LED
Pretravel (PT)
Model
WLGCA2-LE
WLGCA2-LD
5° +2°
0°
Switches with Fork Lock Lever Actuator
Retention type Switches
Actuator
Fork lock lever
Fork lock lever
Fork lock lever
Indicator *
Neon lamp
LED
Pretravel (PT)
55° max.
Model
WLCA32-41LE-N
WLCA32-41LD-N
Model
WLCA32-42LE-N
---
Model
WLCA32-43LE-N
WLCA32-43LD-N
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
17
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Actuator
Sealed Top-roller
plunger
Sealed Top-ball
plunger
Sealed Top plunger
Top-roller plunger
Indicator *
Neon lamp
LED
Pretravel (PT)
1.7 mm max.
Model
WLD18-LE-N
WLD18-LD-N
Model
WLD28-LE-N
WLD28-LD-N
Model
WLD38-LE-N
WLD38-LD-N
Model
WLD2-LE-N
WLD2-LD-N
Actuator
Horizontal plunger
Horizontal-roller plunger
Horizontal-ball plunger
Indicator *
Neon lamp
LED
Pretravel (PT)
2.8 mm max.
Model
WLSD-LE-N
WLSD-LD-N
Model
WLSD2-LE-N
WLSD2-LD-N
Model
WLSD3-LE-N
WLSD3-LD-N
Switches with Flexible Rod Actuators
Basic Switches
Actuator
Coil spring
Coil spring
(spring diameter: 6.5)
(spring diameter: 8)
Indicator *
Neon lamp
LED
Pretravel (PT)
20±10 mm
Model
WLNJ-LE-N
WLNJ-LD-N
Model
WLNJ-30LE-N
WLNJ-30LD-N
Actuator
Resin rod
Steel wire
(rod diameter: 8)
(wire diameter: 1)
Indicator *
Neon lamp
LED
Pretravel (PT)
40±20 mm
Model
WLNJ-2LE-N
WLNJ-2LD-N
Model
WLNJ-S2LE-N
WLNJ-S2LD-N
* The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating
(NC wiring).
18
WL-N/WL
General-purpose Switches
Sensor I/O Connector Switches
Switches with Direct-wired Connectors
Basic Switches
Actuator
Roller lever: R38
Model
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
AC
Pretravel (PT)
3
4
NO only 2 core
NC + NO 4 core
NO only 2 core
NC + NO 4 core
NO only 2 core
NC + NO 4 core
NO
WLCA2-LDK13A-N
WLCA2-LDK43A-N
WLCA2-LDK13-N
WLCA2-LDK43-N
WLCA2-55LDK13-N
WLCA2-55LDK43-N
1
3
2
4
NC
NO
General-
purpose
3
4
NO
Threaded
DC
DC
15±5°
1
3
2
4
NC
NO
3
4
NO
Airtight
1
3
2
4
NC
NO
Actuator
Sealed Top-roller plunger
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
DC
Pretravel (PT)
Model
3
4
NO only 2 core
NC + NO 4 core
NO only 2 core
NC + NO 4 core
NO
WLD28-LDK13-N
WLD28-LDK43-N
WLD28-55LDK13-N
WLD28-55LDK43-N
General-
purpose
1
3
2
4
NC
NO
Threaded
1.7 mm max.
3
4
NO
Airtight
DC
1
3
2
4
NC
NO
High-sensitivity Switches
Actuator
Roller lever: R38
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
DC
Pretravel (PT)
Model
3
4
NO only 2 core
NC + NO 4 core
NO only 2 core
NC + NO 4 core
NO
WLG2-LDK13
WLG2-LDK43
WLG2-55LDK13
WLG2-55LDK43
General-
purpose
1
3
2
4
NC
NO
+2°
Threaded
10°
-1°
3
4
NO
Airtight
1
3
2
4
NC
NO
High-precision Switches
Actuator
Roller lever: R38
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
DC
Pretravel (PT)
Model
3
4
NO only 2 core
NC + NO 4 core
NO only 2 core
NC + NO 4 core
NO
WLGCA2-LDK13
WLGCA2-LDK43
WLGCA2-55LDK13
WLGCA2-55LDK43
General-
purpose
1
3
2
4
NC
NO
Threaded
5° +2°
0°
3
4
NO
Airtight
1
3
2
4
NC
NO
Note: The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180 to change the setting to light-ON when operating (NC wiring).
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
°
19
WL-N/WL
Switches with Pre-wired Connectors
Basic Switches
Actuator
Roller lever: R38
Model
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
Pretravel (PT)
3
1
3
4
4
2
NO
NO
NC
WLCA2-LD-M1J-N
WLCA2-LD-M1GJ-N
WLCA2-LD-M1JB-N
NO only 2 core
NC only 2 core
NC + NO 4 core
General-
purpose
1
3
2
4
NC
NO
WLCA2-LD-DGJ-N
3
2
4
NO
NC
NO only 3 core
NO only 2 core
WLCA2-LD-DK1EJ-N
Threaded *
DC
15±5°
3
1
3
4
4
2
NO
NO
NC
WLCA2-55LD-M1J-N
WLCA2-55LD-M1GJ-N
WLCA2-55LD-M1JB-N
NC only 2 core
NC + NO 4 core
Airtight
1
3
2
4
NC
NO
WLCA2-55LD-DGJ-N
3
2
4
NO
NC
NO only 3 core
WLCA2-55LD-DK1EJ-N
Actuator
Sealed Top-roller Plunger
Model
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
Pretravel (PT)
3
1
4
4
NO
NO
WLD28-LD-M1J-N
WLD28-LD-M1GJ-N
NO only 2 core
General-
purpose
1
3
2
4
NC
NO
NC + NO 4 core
NO only 3 core
WLD28-LD-DGJ-N
3
2
4
NO
NC
WLD28-LD-DK1EJ-N
Threaded *
DC
1.7 mm max.
3
1
3
4
4
2
4
NO
NO
NC
WLD28-55LD-M1J-N
WLD28-55LD-M1GJ-N
WLD28-55LD-M1JB-N
NO only 2 core
Airtight
NC only 2 core
NO only 3 core
3
2
NO
NC
WLD28-55LD-DK1EJ-N
High-sensitivity Switches
Actuator
Pretravel (PT)
+2°
Roller lever: R38
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
DC
Model
3
4
NO only 2 core
NO
WLG2-LD-M1J
WLG2-LD-DGJ03
General-
purpose
1
3
2
4
NC
NO
NC + NO 4 core
Threaded *
10°
-1°
1
3
2
4
NC
NO
Airtight
NC + NO 4 core
WLG2-55LD-DGJ03
High-precision Switches
Actuator
Roller lever: R38
Model
Connector
shape
Built-in switch
specification
Wiring
Specifications
Connector pin
No.
Voltage
DC
Pretravel (PT)
General-
purpose
3
4
NO only 2 core
NO only 2 core
NC + NO 4 core
NO
NO
WLGCA2-LD-M1J
Threaded *
5° +2°
WLGCA2-55LD-M1J
WLGCA2-55LD-DGJ03
3
4
0°
Airtight
1
3
2
4
NC
NO
* The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths.
Note: The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180
° to change the setting to light-ON when operating (NC wiring).
(However, Three-core and Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
20
WL-N/WL
Contact Forms
Wiring specification
Screw terminal types
No indicator
Operation indicator (Light-ON when Not Operating) Switches
High-sensitivity/
Basic Switches
Basic Switches
High-sensitivity/
High-precision Switches
High-precision Switches
Internal
circuits
Internal
circuits
Za
Za
(NO) 4
3 (NO)
14 (NO)
11 (NC)
13 (NO)
12 (NC)
Za
Za
14 (NO)
13 (NO)
12 (NC)
(NO) 4
(NC) 1
3 (NO)
(NC) 1
2 (NC)
11 (NC)
2 (NC)
Direct-wire Connector and Pre-wired Connector types
No indicator
Basic
High-sensitivity/High-precision Switches
AC
DC
AC
DC
Za
Za
Za
Za
NO NC
NC NO
NO NC
NC NO
NO NC
NC NO
NO NC
NC NO
2 core
4 core
4
4
---
1
---
2
3
3
2 core
4 core
4
---
---
3
4
---
---
3
4
4
---
---
---
2
3
4
1
2
3
4
---
3
---
2
1
2 core
---
3
1
2 core
---
---
---
---
1
2
3
4
indicate the connector
1
2
3
4
indicate the connector
pin number.
pin number.
4
4
---
1
2
2
3
3
4 core
4
1
2
3
3 core
4 core
1
2
3
4
indicate the connector
pin number.
1
2
3
4
indicate the connector
pin number.
Operation indicator (Light-ON when Not Operating) Switches
Basic
High-sensitivity/High-precision Switches
Internal
Internal
Internal
Internal
AC
DC
circuits
circuits
circuits
circuits
AC
DC
Za
Za
Za
Za
NO NC
NC NO
NO NC
NC NO
NO NC
NC NO
NO NC
NC NO
2 core
4 core
4
4
---
1
---
2
3
3
2 core
4 core
4
---
---
3
4
4
---
---
3
---
---
2
3
1
4
---
---
3
2 core
4 core
4
1
2
3
4
---
3
---
2
1
2 core
---
---
---
---
1
2
3
4
indicate the connector
1
2 3 4 indicate the connector
pin number.
pin number.
4
4
---
1
2
2
3
3
4
1
2
3
3 core
4 core
1
2
3
4
indicate the connector
pin number.
1
2
3
4
indicate the connector
pin number.
Connector Pin Layout Diagram
Basic/High-sensitivity/High-precision Switches
Positioning piece *2
AC
DC
Positioning piece *2
2
2
3
1
3
1
4
4
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when not operating means the operation indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close
when the actuator rotates or is pushed down.
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight
connector.
21
WL-N/WL
Connecting Sensor I/O connector cable (Socket)
Number of cable
cores
Cable length
L (m)
Applicable limit switch
models
Type
AC/DC Type
Model
2 m
5 m
2 m
5 m
2 m
5 m
2 m
5 m
2 m
XS2F-A421-DB0-F
XS2F-A421-GB0-F
XS2F-A421-D90-F
XS2F-A421-G90-F
XS2F-D421-DD0
XS2F-D421-GD0
XS2F-D421-DA0-F
XS2F-D421-GA0-F
XS2F-D421-D80-F
2
4
WL@-@K13A-N
AC
WL@-@K43A-N
WL@-@-AGJ-N
M12 Screw (Straight)
WL@-@K13-N
WL@-@-M1J-N
2
WL@-@-M1GJ@-N
DC
DC
WL@-@K43-N
WL@-@-M1JB-N
WL@-@-DGJ-N
4
4
5 m
2 m
XS2F-D421-G80-F
XS5F-D421-D80-F
M12 Smart click type (Straight)
WL@-@-M1TJ-N
WL@-@-M1TJB-N
5 m
XS5F-D421-G80-F
Dimensions (Unit: mm)
XS2F-@421-@@0-@
XS2F-D421-@D0
L (Cable length)
40.7
6 dia.
14.9 dia.
DC
AC
30
5
50
Wiring Diagram
Two-core model
Wiring Diagram
Four-core model
Wiring Diagram
AC/DC Type
Model
Model
Terminal No.
Cable color of
core sheath
1
2
3
4
XS2F-A421-DB0-F
XS2F-A421-GB0-F
XS2F-A421-D90-F
XS2F-A421-G90-F
AC
DC
Brown
Blue
Terminal No.
Cable color of
core sheath
Terminal No.
Cable color of
core sheath
1
2
3
4
1
2
3
4
XS2F-D421-DD0
XS2F-D421-GD0
Brown
White
Blue
Blue
Brown
Black
XS2F-D421-D80-F
XS2F-D421-G80-F
Terminal No.
Cable color of
core sheath
1
2
3
4
XS2F-D421-DA0-F
XS2F-D421-GA0-F
Brown
Blue
XS5F-D421-@80-F
Wiring Diagram
L (Cable length)
40.7
6 dia.
Four-core model
Wiring Diagram
AC/DC Type
14.9 dia.
Model
Terminal No.
Cable color of
core sheath
30
5
50
XS5F-D421-D80-F
XS5F-D421-G80-F
1
2
3
4
Brown
White
Blue
DC
Black
22
WL-N/WL
Environment-resistant Switches
Switches with Roller Lever Actuators
Basic Switches
Adjustable rod lever:
25 to 140 mm
Actuator
Roller lever: R38
Adjustable roller lever
Built-in switch specification
Model
WLCA2-55-N
Model
Model
WLCA12-55-N
WLCL-55-N
Airtight seal
WLCA2-255-N
WLCA2-2N55-N
WLCA2-139-N
WLCA2-2139-N
WLCA2-2N139-N
WLCA2-140-N
---
---
---
---
WLCA12-139-N
---
---
WLCL-139-N
Molded terminals, -139 models
Molded terminals, -140 models
Molded terminals, -141 models
Anti-coolant
---
---
---
WLCL-140-N
---
WLCA12-140-N
---
WLCA2-2N140-N
WLCA2-141-N
---
---
---
Hermetic
seal *
WLCA12-141-N
---
---
---
---
---
---
WLCA2-RP60-N
WLCA2-2RP60-N
---
WLCA12-RP60-N
---
WLCL-RP60-N
---
---
---
WLCA2-TH-N
WLCA2-2TH-N
WLCA2-2NTH-N
WLCA2-TC-N
WLCA2-2TC-N
WLCA2-2NTC-N
WLCA2-RP-N
WLCA2-P1-N
WLCA12-TH-N
WLCA12-2TH-N
WLCA12-2NTH-N
WLCA12-TC-N
WLCA12-2TC-N
WLCA12-2NTC-N
WLCA12-RP-N
WLCA12-P1-N
WLCL-TH-N
WLCL-2TH-N
WLCL-2NTH-N
WLCL-TC-N
WLCL-2TC-N
WLCL-2NTC-N
WLCL-RP-N
WLCL-P1-N
Heat-resistant
Low-temperature
Corrosion-proof
Weather-proof
* The maximum cable length for a Hermetic Switch is 5 m.
High-sensitivity Switches
Adjustable rod lever:
25 to 140 mm
Actuator
Roller lever: R38
Model
Adjustable roller lever
Built-in switch specification
Model
Model
Airtight seal
WLG2-55
WLG2-139
WLG2-140
WLG2-141
---
---
Molded terminals, -139 models
Molded terminals, -140 models
Molded terminals, -141 models
Anti-coolant
---
---
---
---
Hermetic
seal *
---
---
WLG2-RP60
WLG2-TH
WLG2-TC
WLG2-RP
WLG2-P1
---
---
Heat-resistant
Low-temperature
Corrosion-proof
Weather-proof
WLG12-TH
WLG12-TC
WLG12-RP
WLG12-P1
WLGL-TH
WLGL-TC
WLGL-RP
WLGL-P1
* The maximum cable length for a Hermetic Switch is 5 m.
High-precision Switches
Actuator
Roller lever: R38
Built-in switch specification
Model
WLGCA2-55
Airtight seal
Molded terminals, -139 models
Molded terminals, -140 models
Molded terminals, -141 models
Anti-coolant
WLGCA2-139
WLGCA2-140
WLGCA2-141
WLGCA2-RP60
WLGCA2-TH
WLGCA2-TC
WLGCA2-RP
---
Hermetic
seal *
Heat-resistant
Low-temperature
Corrosion-proof
Weather-proof
* The maximum cable length for a Hermetic Switch is 5 m.
23
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Sealed Top-roller
plunger
Horizontal-roller
plunger
Actuator
Top-roller plunger
Horizontal plunger
Built-in switch specification
Model
Model
WLD2-55-N
WLD2-139-N
---
Model
WLSD-55-N
WLSD-139-N
---
Model
Airtight seal
WLD28-55-N
WLD28-139-N
WLD28-140-N
WLD28-RP60-N
WLD28-TH-N
---
WLSD2-55-N
Molded terminals, -139 models
Molded terminals, -140 models
Anti-coolant
WLSD2-139-N
WLSD2-140-N
WLSD2-RP60-N
WLSD2-TH-N
WLSD2-TC-N
WLSD2-RP-N
Hermetic
seal *
WLD2-RP60-N
WLD2-TH-N
---
WLSD-RP60-N
WLSD-TH-N
WLSD-TC-N
WLSD-RP-N
Heat-resistant
Low-temperature
Corrosion-proof
WLD28-RP-N
---
* The maximum cable length for a Hermetic Switch is 5 m.
Switches with Flexible Rod Actuators
Basic Switches
Coil spring
Actuator
Resin rod
(rod diameter: 8)
(spring diameter: 6.5)
Built-in switch specification
Airtight seal
Model
WLNJ-55-N
Model
WLNJ-255-N
WLNJ-2139-N
WLNJ-2140-N
WLNJ-2RP60-N
---
Molded terminals, -139 models
Molded terminals, -140 models
Anti-coolant
WLNJ-139-N
WLNJ-140-N
WLNJ-RP60-N
WLNJ-TH-N
WLNJ-TC-N
WLNJ-RP-N
Hermetic
seal *
Heat-resistant
Low-temperature
Corrosion-proof
---
WLNJ-2RP-N
* The maximum cable length for a Hermetic Switch is 5 m.
24
WL-N/WL
Environment-resistant Switches
Operation indicator Switches
Switches with Roller Lever Actuators
Basic Switches
Adjustable rod lever:
25 to 140 mm
Actuator
Roller lever: R38
Model
Adjustable roller lever
Model
Wiring
Built-in switch specification
Airtight seal
Indicator *
Neon lamp
Model
Specifications
NO wiring
NO wiring
NO wiring
NO wiring
NO wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
WLCA2-55LE-N
WLCA12-55LE-N
---
WLCA2-255LE-N
WLCA2-2N55LE-N
WLCA2-55LD-N
---
---
---
---
WLCA12-55LD-N
WLCL-55LD-N
LED
WLCA2-255LD-N
WLCA2-2N55LD-N
WLCA2-139LD2-N
WLCA2-139LD3-N
WLCA2-2139LD2-N
WLCA2-2139LD3-N
WLCA2-141LD2-N
WLCA2-141LD3-N
WLCA2-RP60LD2-N
WLCA2-RP60LD3-N
WLCA2-2RP60LD2-N
WLCA2-2RP60LD3-N
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
Moldedterminals,
-139 models
Hermetic Moldedterminals,
LED
seal
-140 models
Anti-coolant
High-sensitivity Switches
Actuator
Roller lever: R38
Model
Wiring
Specifications
Built-in switch specification
Airtight seal
Indicator *
Neon lamp
LED
NO wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
WLG2-55LE
WLG2-55LD
---
Moldedterminals,
-139 models
WLG2-139LD3
WLG2-140LD2
WLG2-140LD3
WLG2-141LD2
WLG2-141LD3
WLG2-RP60LD2
WLG2-RP60LD3
Moldedterminals,
-140 models
Hermetic
LED
seal
Moldedterminals,
-141 models
Anti-coolant
High-precision Switches
Actuator
Roller lever: R38
Model
Wiring
Specifications
Built-in switch specification
Airtight seal
Indicator *
Neon lamp
LED
NO wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
NC wiring
NO wiring
WLGCA2-55LE
WLGCA2-55LD
WLGCA2-139LD2
WLGCA2-139LD3
WLGCA2-140LD2
WLGCA2-140LD3
---
Moldedterminals,
-139 models
Moldedterminals,
-140 models
Hermetic
LED
seal
Moldedterminals,
-141 models
WLGCA2-141LD3
WLGCA2-RP60LD2
WLGCA2-RP60LD3
Anti-coolant
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180 to change the setting to light-ON when operating (NC wiring).
(Note that the lamp holder cannot be replaced on hermetic models.)
°
25
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Sealed top-roller
plunger
Horizontal-roller
plunger
Actuator
Top-roller plunger
Model
Horizontal plunger
Model
Internal
Wiring
switch
Indicator *
Model
Model
Specifications
Specifications
Neon lamp
LED
NO wiring
NO wiring
WLD28-55LE-N
WLD28-55LD-N
WLD2-55LE-N
WLD2-55LD-N
---
---
Airtight seal
WLSD-55LD-N
WLSD2-55LD-N
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180 to change the setting to light-ON when operating (NC wiring).
°
Switches with Flexible Rod Actuators
Basic Switches
Coil spring
(spring diameter: 6.5)
Resin rod
(rod diameter: 8)
Actuator
Internal
switch
Specifications
Wiring
Specifications
Model
Model
Indicator *
Neon lamp
LED
NO wiring
NO wiring
---
WLNJ-55LD-N
---
WLNJ-255LD-N
Airtight seal
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180 to change the setting to light-ON when operating (NC wiring).
°
26
WL-N/WL
Spatter-prevention Switches
Basic Switches
Actuator
Roller lever: R38
Sealed Top-roller
plunger
Double nut lever
Allen-head lever
Indicator *
Model
WLCA2-LEAS-N
WLCA2-LDAS-N
Model
WLCA2-LES-N
WLCA2-LDS-N
Model
WLD28-LES-N
WLD28-LDS-N
Neon lamp
LED
High-sensitivity Switches
Actuator
Roller lever: R38
Double nut lever
Model
Allen-head lever
Indicator *
Model
WLG2-LES
Neon lamp
LED
WLG2-LEAS
WLG2-LDAS
WLG2-LDS
High-precision Switches
Actuator
Roller lever: R38
Double nut lever
Allen-head lever
Model
Indicator *
Model
---
Neon lamp
LED
WLGCA2-LES
WLGCA2-LDS
---
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180 to change the setting to light-ON when operating (NC wiring).
°
27
WL-N/WL
Long-life Switches
Basic Switches
Indicator
*1
AC/DC
Type
Wiring
Specifications
Connectors
pin No.
Actuator
Model
Roller lever
Screw terminal type
AC/DC
---
---
WLMCA2-LD-N
3
4
2-conductor
4-conductor
2-conductor
4-conductor
NO
WLMCA2-LDK13A-N
WLMCA2-LDK43A-N
WLMCA2-LDK13-N
WLMCA2-LDK43-N
AC
DC
1
3
2
4
NC
NO
Roller lever
Direct-wire Connector
type
3
4
NO
LED
1
3
2
4
NC
NO
3
4
2-conductor
4-conductor
NO
WLMCA2-LD-M1J-N
WLMCA2-LD-DGJ-N
Roller lever
Pre-wired Connector
type *2
DC
1
3
2
4
NC
NO
*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180 to change the setting to light-ON when operating (NC wiring).
°
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
*2. With 0.3-m cable.
High-sensitivity/High-precision Switches
High-sensitivity
Model
High-precision Models
Model
Indicator
*1
AC/DC
Type
Wiring
Specifications
Connectors
pin No.
Actuator
Roller lever
Screw terminal type
AC/DC
---
---
WLMG2-LD
WLMGCA2-LD
3
4
2-conductor
4-conductor
2-conductor
4-conductor
NO
WLMG2-LDK13A
WLMG2-LDK43A
WLMG2-LDK13
WLMG2-LDK43
WLMGCA2-LDK13A
WLMGCA2-LDK43A
WLMGCA2-LDK13
WLMGCA2-LDK43
AC
DC
1
3
2
4
NC
NO
Roller lever
Direct-wire Connector
type
3
4
NO
LED
1
3
2
4
NC
NO
3
4
2-conductor
4-conductor
NO
WLMG2-LD-M1J
WLMGCA2-LD-M1J
---
Roller lever
Pre-wired Connector
type *2
DC
1
3
2
4
NC
NO
WLMG2-LD-DGJ03
*1. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180 to change the setting to light-ON when operating (NC wiring).
°
(However, Four-core Switches cannot be switched to light-ON when operating (NC wiring).)
*2. With 0.3-m cable.
28
WL-N/WL
Individual Parts
Switches without Levers, Heads, and Actuators
General-purpose Parts
Switches without
levers
Heads
(with Actuators)
Actuator only *
Model
Operating
characteristics
Actuator
Set
Model
WLRCA2-N
WLRCA2-2-N
WLRCA2-2N-N
WLRG2
Model
WL-1H1100-N
WL-3H1100-N
WL-1H1100-N
WL-2H1100
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
WLG2
Basic
Roller lever
WL-1A100
High-sensitivity
Basic
WLCA12-N
WLCA12-2-N
WLCA12-2N-N
WLG12
WLRCA2-N
WLRCA2-2-N
WLRCA2-2N-N
WLRG2
WL-1H2100-N
WL-3H2100-N
WL-1H2100-N
WL-2H2100
Adjustable roller
lever
WL-2A100
WL-4A100
High-sensitivity
Basic
WLCL-N
WLRCL-N
WL-4H4100-N
WL-3H4100-N
WL-1H4100-N
WL-2H4100
WLCL-2-N
WLCL-2N-N
WLGL
WLRCA2-2-N
WLRCA2-2N-N
WLRG2
Variable rod lever
Fork lock lever
High-sensitivity
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-44-N
WLD18-N
WL-5H5100-N
WL-5H5102-N
WL-5H5104-N
WL-5H5104-N
WL-7H100-N
WL-7H400-N
WL-7H300-N
WL-8H100-N
WL-8H200-N
WL-8H300-N
WL-9H100-N
WL-9H200-N
WL-9H300-N
WL-9H400-N
WL-5A100
WL-5A102
WL-5A104
WL-5A104
Basic
WLRCA32-N
---
Top plunger
Basic
Basic
WLD28-N
---
---
---
---
---
---
---
---
---
---
---
WLD38-N
WLSD-N
Horizontal plunger
WLSD2-N
WLSD3-N
WLNJ-N
WLNJ-30-N
WLNJ-2-N
WLNJ-S2-N
Flexible rod
Basic
---
* The same Actuators can be used for both WL and WL-N Switches.
Spatter-prevention Parts
Switches without
levers
Heads
(with Actuators)
Actuator only *
Model
Lever
Specifications
Actuator
Item
Set Model Numbers
Model
WLRCA2-LES-N
WLRCA2-LDS-N
WLRG2-LDS
Model
WLCA2-LES-N
WLCA2-LDS-N
Basic
Allen-head bolt
lever
---
WL-1A103S
High-sensitivity WLG2-LDS
Roller lever
WLCA2-LEAS-N
Basic
WLRCA2-LES-N
WLRCA2-LDS-N
WLRG2-LDS
Double nut lever
WLCA2-LDAS-N
---
WL-1A105S
High-sensitivity WLG2-LDAS
* The same Actuators can be used for both WL and WL-N Switches.
29
WL-N/WL
Covers with Indicators(See Note.)
General-purpose/Long-life Parts
Basic Parts
Cover
Color
Cover only *1
Model
Indicator *2
Neon lamp
Orange
Red
WL-LE-N *3
WL-LD-N
LED
Yellow
WL-LW-N *3
High-sensitivity/High-precision Parts
Cover
Color
Cover only *1
Model
Indicator *2
Neon lamp
LED
Orange
Red
WL-LE
WL-LD
*1. The Covers are not compatible with Basic Switches (WL-N), or High-sensitivity/High-precision Switches (WL).
*2. The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
*3.
The Color Universal Design structure is certified by an NPO.
Certification conditions: Ambient illumination of 500 lx max. (JIS
Z 9110)
Color Universal Design was developed in consideration of
people with various types of color vision to allow information to
be accurately conveyed to as many individuals as possible.
Spatter-prevention Parts
Basic Parts
Cover
Color
Cover only
Model
Indicator *
Neon lamp
LED
Orange
Red
WL-LES-N
WL-LDS-N
* The default setting is light-ON when not operating (NO wiring).
Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring).
30
WL-N/WL
Specifications
General-purpose/Environment-resistant Switches
Ratings
Wiring Specifications
Screw terminal types
Standard-load Switches (excluding micro-load Switches)
Micro-load Switches (Refer to these ratings before using the product.)
Non-inductive load (A)
Inductive load (A)
Rated voltage (V)
AC125
Rated current (A) - Resistive load
Rated
voltage
(V)
Resistive
load
Lamp
load
Inductive
load
Motor
load
Item
0.1
DC 30
NC NO NC NO NC NO NC NO
Note: The load is a resistive load.
AC 125
250
10
10
10
3
2
1.5
1
10
10
3
5
3
2.5
1.5
Operation in the following ranges will produce optimum performance.
500
1.5 0.8
1.5 0.8
5 to 30 VDC
Recommended load range
DC
8
14
30
10
10
6
6
6
4
3
3
3
10
10
6
6
6
4
Basic
0.16 to 100 mA
125
250
0.8
0.4
0.2 0.2
0.1 0.1
0.8
0.4
0.2
0.1
AC 125
250
5
5
High-
sensitivity
High-
----
----
----
----
----
----
DC 125
250
0.4
0.2
30
precision *1
Note: 1. The above figures are for steady-state currents.
10
5
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
0.8 W
5 mW
3. A lamp load has an inrush current of 10 times the steady-
state current.
4. A motor load has an inrush current of 6 times the steady-
state current.
1
0.1 0.16
1
5
10
100
Current (mA)
Operating characteristics
High-sensitivity,
High-precision
Minimum applicable load
NC
NO
30 A max. (15 A max. *1)
20 A max. (10 A max. *1)
Inrush current
5 VDC 1 mA N level reference value
*1. For High-sensitivity and High-precision Switches.
Operating characteristics
Basic
Minimum applicable load
Operation indicator Switches
Operation Indicator
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, resistive load, N level
reference value
Model
Max. rated voltage (V) Leakage current (mA)
125 VAC
250 AC
Approx. 0.6
Approx. 1.9
Approx. 0.4
WL-LE-N
WL-LE
Direct-wired connector and Pre-wired Connector type
Neon lamp
LED
Non-inductive load (A)
Inductive load (A)
WL-LD-N
WL-LW-N
WL-LD
10 to 24 VAC/DC
Rated
voltage
(V)
Resistive
load
Lamp
load
Inductive
load
Motor
load
Item
115 VAC/DC
Approx. 0.5
NC NO NC NO NC NO NC NO
AC 115
3
3
1.5
3
3
2.5
DC 12
24
3
3
0.8
3
3
0.2
3
3
0.8
3
3
0.2
Basic
115
High-
AC 115
3
----
----
----
sensitivity
High-
precision *1
DC 115
0.4
----
----
----
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-
state current.
4. A motor load has an inrush current of 6 times the steady-
state current.
NC
NO
3 A max.
3 A max.
Inrush current
Operating characteristics
Basic
Minimum applicable load
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, RESISTIVE Load, N
level reference value
31
WL-N/WL
Characteristics
Degree of protection
IP67
Mechanical
15,000,000 operations min. *2
Durability *1
Electrical
750,000 operations min.
(3 A at 250 VAC, resistive load) *3
Operating speed
1 mm to 1 m/s (for WLCA2-N)
120 operations/minute min.
30 operations/minute min.
50/60 Hz
Mechanical
Electrical
Operating
frequency
Rated frequency
Insulation resistance
100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value for the
built-in switch when tested alone)
Contact resistance
Between terminals
1,000 VAC (600 VAC) 50/60 Hz
of the same polarity 1 min
Between currentcar-
rying metal part and
ground
2,200 VAC (1,500 VAC) 50/60 Hz
1 min *5
Dielectric
strength
Between each termi-
nal and non-current-
carrying metal part
2,200 VAC (1,500 VAC) 50/60 Hz
1 min *5
Vibration
resistance
10 to 55 hz, 1.5-mm double
amplitude *6
Malfunction
Destruction
Malfunction
1,000 m/s2 max.
300 m/s2 *6
Shock
resistance
Ambient operating temperature
Ambient operating humidity
Weight
-10 to +80°C (with no icing) *7
35% to 95% RH
Approx. 255 g (for WLCA2-N)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision switches models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70% RH.
Contact your OMRON sales representative for more detailed
information on other operating environments.
*2. High-sensitivity models and Flexible Rod models: 10 million
operations min.
500,000 operations min. for Weather-resistant models.
*3. High-sensitivity models, High-precision models, and Weather-
proof models are 500,000 operations min.
Micro-load models are 1 million operations min.
Contact your OMRON representative for information on Airtight
models and Hermetic models.
*4. Micro-load models and Weather-proof models are 50 mΩ or less
(default value, built-in switch only).
*5. Sensor I/O connector type is 1,500 V.
*6. Except Flexible Rod models. Micro-load models are 200 m/s2 max.
*7. For low-temperature models this is –40°C to +40°C (with no icing).
For heat-resistant models the range is +5°C to +120°C.
32
WL-N/WL
Spatter-prevention Switches
Ratings
Wiring Specifications
Screw terminal types
Characteristics
Degree of protection
IP67
Mechanical
Durability *1
Electrical
15,000,000 operations min. *2
750,000 operations min.
(3 A at 250 VAC, resistive load) *3
Non-inductive load (A)
Inductive load (A)
Rated
voltage
(V)
Resistive
load
Lamp
load
Inductive
load
Motor
load
1 mm to 1 m/s (in case of WLCA2-
LDS-N)
Item
Operating speed
NC NO NC NO NC NO NC NO
Mechanical
Electrical
120 operations/minute min.
30 operations/minute min.
50/60Hz
Operating
frequency
AC 125
250
10 (5)
10 (5)
3
2
1.5
1
10
10
5
3
2.5
1.5
WL
WL
@
-LES-N
Rated frequency
AC 115
10 (5)
3
1.5
10
5
2.5
Insulation resistance
100 MΩ min. (at 500 VDC)
DC 12
24
10
6
6
4
3
3
10
6
0.8
6
4
0.2
@-LDS-N
25 mΩ max. (initial value for the
built-in switch)
Contact resistance
115
0.8(0.4) 0.2 0.2
Between terminals
of the same polarity 1 min
1,000 VAC (600 VAC) 50/60 Hz
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-
state current.
Between currentcar-
rying metal part and
ground
2,200 VAC (1,500 VAC) 50/60 Hz
1 min *4
Dielectric
strength
4. A motor load has an inrush current of 6 times the steady-
Between each termi-
nal and non-current-
carrying metal part
2,200 VAC (1,500 VAC) 50/60 Hz
1 min *4
state current.
5. The figures in parentheses for resistive load are those for
the high-sensitivity and high-precision switches models.
Vibration
resistance
10 to 55 hz, 1.5-mm double ampli-
tude
1,000 m/s2 max.
Malfunction
NC
NO
30 A max. (15 A max. *)
20 A max. (10 A max. *)
Inrush current
Destruction
Malfunction
Shock
resistance
300 m/s2 max.
* For High-sensitivity and High-precision Switches.
Ambient operating temperature
Ambient operating humidity
-10 to +80°C (with no icing)
35% to 95% RH
Operating characteristics
Basic
Minimum applicable load
Approx. 255 g (in case of WLCA2-
LDS-N)
5 VDC 1 mA, resistive load, P level
Weight
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision switches models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed
information on other operating environments.
*2. High-sensitivity models are 10 million operations min.
*3. High-sensitivity models and High-precision models are 500,000
operations min.
Direct-wired connector and Pre-wired Connector type
Non-inductive load (A)
Inductive load (A)
Rated
voltage
(V)
Resistive
load
Lamp
load
Inductive
load
Motor
load
Item
NC NO NC NO NC NO NC NO
AC 115
3
3
1.5
3
3
2.5
DC 12
24
3
3
0.8
3
3
0.2
3
3
0.8
3
3
0.2
Basic
Micro-load models are 10 million operations min.
Contact your OMRON representative for information on Airtight
switches.
115
High-
AC 115
3
----
----
----
*4. Sensor I/O connector type is 1,500 V.
sensitivity
High-
precision *1
DC 115
0.4
----
----
----
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-
state current.
4. A motor load has an inrush current of 6 times the steady-
state current.
NC
NO
3 A max.
3 A max.
Inrush current
Operating characteristics
Basic
Minimum applicable load
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Operation indicator Switches
Operation Indicator
Model
Max. rated voltage (V) Leakage current (mA)
125 VAC
250 VAC
Approx. 0.6
Approx. 1.9
Approx. 0.4
Approx. 0.5
WL-LES-N
WL-LE
Neon lamp
LED
10 to 24 VAC/DC
115 VAC/DC
WL-LDS-N
WL-LD
33
WL-N/WL
Long-life Switches
Ratings
Wiring Specifications
Screw terminal type
Characteristics
Degree of protection
IP67
Mechanical
30,000,000 operations min.
30,000,000 operations min. (10 mA
at 24 VDC, resistive load)
750,000 operations min. (3 A at
115 VAC, resistive load), but for
high-precision models:
Non-inductive load
(A)
Inductive load (A)
Rated
voltage
(V)
Durability *1
Electrical
Item
Resistive
load
Lamp
load
Inductive
load
Motor
load
High-sensitivity and High-precision
Switches: 500,000 operations min.
NC NO NC NO NC NO NC NO
AC 115
10
3
1.5
10
5
2.5
1 mm to 1 m/s
(in case of WLMCA2-LD-N)
DC
12
24
10
6
0.8
6
4
3
3
10
6
0.8
6
4
0.2
Operating speed
Basic
Mechanical
Operating
frequency
120 operations/min.
30 operations/min.
50/60 Hz
115
0.2 0.2
High-
sensitivity
High-
Electrical
AC 115
DC 115
5
----
----
----
----
Rated frequency
0.4
----
----
Insulation resistance
100 MΩ min. (at 500 VDC)
precision *
25 mΩ max. (initial value for the
built-in switch when tested alone)
*2
Note: 1. The above figures are for steady-state currents.
Contact resistance
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-
state current.
Between terminals
1,000 VAC (600 VAC), 50/60 Hz
of the same polarity 1 min
Dielectric
strength
(50/60 Hz
1 min.)
Between currentcar-
rying metal part and
ground
A motor load has an inrush current of 6 times the steady-
state current.
2,200 VAC (1,500 VAC) 50/60 Hz
1 min *3
NC
NO
30 A max. (15 A max. *)
20 A max. (10 A max. *)
Between each termi-
nal and non-current-
carrying metal part
Inrush current
2,200 VAC (1,500 VAC) 50/60 Hz
1 min *3
* For High-sensitivity and High-precision Switches.
Vibration
resistance
10 to 55 Hz, 1.5-mm double ampli-
tude
Malfunction
Operating characteristics
Basic
Minimum applicable load
Destruction
Malfunction
1,000 m/s2 max.
300 m/s2 max. *4
Shock
resistance
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Ambient operating temperature
Ambient operating humidity
-10 to +80°C (with no icing)
35% to 95% RH
Approx. 255 g
(in case of WLMCA2-LD-N)
Direct-wired connector and Pre-wired Connector type
Weight
Non-inductive load
Inductive load (A)
Note: 1. The above figures are initial values.
(A)
Rated
voltage
(V)
2. The figures in parentheses for dielectric strength are those
for the high-sensitivity and high-precision switches models.
*1. The values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed
information on other operating environments.
Item
Resistive
load
Lamp
load
Inductive
load
Motor
load
NC NO NC NO NC NO NC NO
AC 115
3
3
1.5
3
3
2.5
DC
12
24
3
3
0.8
3
3
0.2
3
3
0.8
3
3
0.2
Basic
*2. For microload models, the contact resistance is 50 mΩ max.
115
(initial value for built-in switch).
High-
sensitivity
High-
AC 115
3
----
----
----
*3. Sensor I/O connector models are 1,500 V.
*4. Micro-load models are 200 m/s2 max.
DC 115
0.4
----
----
----
precision *1
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a
time constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-
state current.
4. A motor load has an inrush current of 6 times the steady-
state current.
NC
NO
3 A max.
3 A max.
Inrush current
Operating characteristics
Basic
Minimum applicable load
5 VDC 1 mA, resistive load, P level
High-sensitivity,
High-precision
5 VDC 160 mA, Resistive load, N level
reference value
Operation indicator Switches
Operation Indicator
Model
Max. rated voltage (V) Leakage current (mA)
WL-LD-N
WL-LW-N
WL-LD
10 to 24 VAC/DC
115 VAC/DC
Approx. 0.4
Approx. 0.5
LED
34
WL-N/WL
General-purpose/Environment-resistant/Spatter-prevention/Long-life Switches
Approved Standards
Agency
UL
Standard
UL508
File No.
Approved models
CSA cUL
CSA C22.2 No.14
EN60947-5-1
GB14048.5
Contact your OMRON representative for information Contact your OMRON representative for information
TÜV Rheinland
CCC (CQC)
Approved Standard Ratings
UL/cUL, CSA (UL508, CSA C22.2 No.14)
Specifications
A600 Authentication conditions
Current (A)
Volt-ampere (VA)
Energizing
current
Approved
Standards
Rated voltage
Make
Break
Make
Break
Indicator Sensor I/O connectors
Item
120 VAC
240 VAC
480 VAC
600 VAC
60
30
15
12
6
3
1.5
1.2
A600
1 A, 125 VDC
Basic Switches
10 A
7,200
720
No Connector
High-sensitivity or
high-precision
A600
No
indicator
C300 Authentication conditions
Basic, high-sensitivity C300
Pre-wired Connector (AC)
or high-precision
3 A, 250 VAC
Current (A)
Volt-ampere (VA)
Energizing
current
Rated voltage
Basic Switches
1 A, 125 VDC
Make
Break
Make
Break
Pre-wired Connector (DC)
Direct-wired Connector (DC)
High-sensitivity or
high-precision
0.8 A, 125 VDC
120 VAC
240 VAC
15
7.5
1.5
0.75
2.5 A
1,800
180
Basic Switches
A300
10 A, 250 VAC
No Connector
A300 Authentication conditions
High-sensitivity or
high-precision
Neon
lamp
Current (A)
Volt-ampere (VA)
Energizing
current
Rated voltage
Basic, high-sensitivity C300
Pre-wired Connector (AC)
Make
Break
Make
Break
or high-precision
3 A, 250 VAC
120 VAC
240 VAC
60
30
6
3
A150
10 A, 115 VAC
1 A, 115 VDC
10 A
7,200
720
Basic Switches
No Connector
A150 Authentication conditions
A150
10 A, 115 VAC
0.8 A, 115 VDC
High-sensitivity or
high-precision
Current (A)
Volt-ampere (VA)
Energizing
current
Rated voltage
120 VAC
LED
Make
Break
Make
Break
Basic, high-sensitivity C150
10 A
60
6
7,200
720
Pre-wired Connector (AC)
or high-precision
3 A, 115 VAC
Basic Switches
1 A, 115 VDC
C150 Authentication conditions
Pre-wired Connector (DC)
Direct-wired Connector (DC)
High-sensitivity or
high-precision
0.8 A,
115 VDC
Current (A)
Volt-ampere (VA)
Energizing
current
Rated voltage
120 VAC
Make
Break
Make
Break
2.5 A
15
1.5
1,800
180
TÜV (EN 60947-5-1)
CCC (GB14048.5)
(Certification Only for Switches with Ground Terminals and DC
Switches with Connectors)
Specification
LED
Authentication
conditions
Neon
lamp
No
With DC
Connector Connector
With AC
indicator
Specification
Working load
category
Authentication
conditions
With ground terminals
AC-15 DC-13 AC-15 AC-15 DC-13
250 V 48 V 250 V 250 V 48 V
2 A
DC-13
AC-15
With DC
Connector
Neon
lamp
No indicator
LED
Rated working
voltage (Ue)
48 V
250 V
Working load
category
AC-15
DC-12
AC-15
AC-15
DC-12
DC-12
Rated working
current (Ie)
Rated working
voltage (Ue)
250 V
48 V
250 V 115 V
48 V
48 V
Conditional
short-circuit
current
1000 A
Rated working
current (Ie)
2 A
Short-circuit
protective
device (SCPD)
Conditional
short-circuit
current
10 A, fuse type gG
100 A
Rated insulation
voltage (Ui)
250 V
Short-circuit
protective
10 A, fuse type gG
device (SCPD)
Rated insulation
voltage (Ui)
250 V
4 kV
48 V
Rated impulse
dielectric
800 V
strength (Uimp)
Pollution degree
3
Electric shock
protection class
Class I
Class III
35
WL-N/WL
Structure and Nomenclature
Basic Switches
Standard Switches
General-purpose Switches: WLCA2-N
Actuator
Head-mounting Screws
Roller
The roller is made of self-lubricating
sintered stainless steel and boasts high
resistance to wear.
Head
Lever
You can remove the two screws to
mount the switch in any of the four
possible orientations.
The lever is forged from corrosion-resistant
aluminum alloy. It provides superior
corrosion resistance and outstanding
strength.
With roller lever, adjustable rod and flexible
rod models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
Shaft Section Seal
An oil seal is fitted on the inlet of the
shaft section to maintain a tight seal.
Roller Lever Bolt
Operational Plunger
You can change the direction of the
operational plunger to electrically switch
the direction of operation between both
sides, left only, or right only.
Set Position Marker Plate
Set the indicator needle so
that it is between protrusions
on the bearing section on the
marker plate after operation.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Head
Set position marker plate
Requires maintenance (excessive overtravel)
Proper range
Terminal Screws
Requires maintenance (insufficient overtravel)
Four, M3.5 screws
Proper range
Requires maintenance (excessive overtravel)
Cover Setscrew
Conduit Opening
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
The conduit screw is a parallel screw
for G1/2 piping, and is used together
with an SC connector to maintain a
tight seal.
Cover
Cover Seal
High sealing performance is achieved. The
seal also serves as a spacer.
There is no troublesome insulating paper,
making it easy to work with the Switch.
36
WL-N/WL
General-purpose Switches:
WLG2
High-sensitivity and High-precision Switches
Actuator
Standard Switches
Head-mounting Screws
Roller
Head
The roller is made of self-lubricating
sintered stainless steel and boasts
high resistance to wear.
By removing the four corner screws, the
head can be mounted in any of four
orientations.
Lever
The lever forged of anti-corrosive
aluminium alloy features high corrosion
resistances and outstanding ruggedness.
With roller lever, adjustable rod and
flexible rod models, the actuator position
can be set anywhere within 360°. (The
lever cannot be mounted in the opposite
direction.)
Shaft Section Seal
By fitting an O-ring to the rotary shaft
and with an appropriate interference
of the screws, high-sealing properties
are maintained.
Roller Lever Setscrew
Operational Plunger
Set Position Marker Plate
After operation, set the indicator needle
on the marker plate so that is in the
convex section of the bearing.
Bearing
The bearing smooths the
plunger movement.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Requires maintenance
(excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
Requires maintenance
(excessive overtravel)
Terminal Screws
Four, M4 screws
Separator
Cover Seal
The separator has outstanding insulation
properties and prevents the generation of any
gases which may corrode the internal parts.
By using a packing seal as the cover seal,
an optimum squeeze can be obtained and
high sealing properties are assured as well.
Conduit Opening
Cover
The conduit screw is a parallel screw for G1
piping, and is used together with an SC
connector to maintain a tight seal.
/2
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling from
the cover even when the screw is loose.
37
WL-N/WL
Operation indicator Switches
Basic Switches
Indicator Covers
Indicator
The indicator covered if outsert molded
from diecast aluminum and has outstanding
sealing properties.
The indicator is either a neon lamp or an
LED. Switches with LED indicators have a
built-in rectifier stack, so there is no
connection polarity.
Indicator Windows
Operating status (i.e., light-ON when
operating or light-ON when not operating)
depends on whether a neon lamp or an
LED is used.
Contact Spring
The built-in switch's terminal screws
are used to connect the indicator
terminal. Since the connection spring
(coil spring) is used for this connection,
it will not be necessary to connect the
indicator terminal. When a ground
terminal is provided however, a lead
wire must be used.
Light-ON when Operating/Not Operating
Lamp Holder
Indicators can be switched from light-ON
when operating and light-ON when not
operating, by simply rotating the indicator
holder by 180°.
(However, Direct-wired Connector,
Pre-wired Connector, Three-core, and
Four-core Switches cannot be switched to
light-ON when operating (NC wiring).)
Light-ON when Operating
Light-ON when Not Operating
LED at top
LED at bottom
Light-ON when Not Operating
Operation
Internal Circuits
Power
Neon lamp
Built-in switch
Contact spring
Resistor
Za
WL@-LE-N
14
11
13
12
Light-ON when
operating *1
Load
Internal
circuits
WL@-LE-N
WL@-LD-N
WL@-LW-N
Rectifier stack
Contact spring
Power
Rated
Internal
circuits
Resistor
Resistor
current
WL@-LD-N
WL@-LW-N
diode
Light-ON when not
operating *2
Za
Zener
diode
Load
14
11
13
12
LED
Built-in switch
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the
actuator rotates or is pushed down.
38
WL-N/WL
Operation indicator Switches
High-sensitivity and High-precision Switches
Indicator
Indicator Covers
The indicator covered if outsert molded from
diecast aluminum and has outstanding sealing
properties.
The indicator is either a neon lamp or an
LED. Switches with LED indicators have a
built-in rectifier stack, so there is no
connection polarity.
Indicator Windows
Operation (i.e., light-ON when operating or
light-ON when not operating) depends on
whether a neon lamp or LED is used.
Contact Spring
The built-in switch's terminal screws are
used to connect the indicator terminal.
Since the connection spring (coil spring) is
used for this connection, it will not be
necessary to connect the indicator terminal.
When a ground terminal is provided
however, a lead wire must be used.
Light-ON when Operating/Not Operating
Indicators can be switched from light-ON when
operating and light-ON when not operating, by
simply rotating the indicator holder by 180°.
(However, Direct-wired Connector, Pre-wired
Connector, Three-core, and Four-core Switches
cannot be switched to light-ON when operating
(NC wiring).)
Light-ON when Operating
Light-ON when Not Operating
LED at top
LED at bottom
Light-ON when Not
Operating
Operation
Internal Circuits
Power
Neon lamp
Built-in switch
Za
Contact spring
Resistor
WLG@-LE
4
1
3
2
Light-ON when
operating *1
Load
Internal circuits
WLG@-LE
WLG@-LD
Rectifier stack
Contact spring
Power
Rated
current
diode
Resistor
Resistor
Internal circuits
WLG@-LD
Light-ON when
not operating *2
Za
Zener
diode
Load
4
1
3
2
LED
Built-in switch
Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current
is higher than the leakage current.
For countermeasures, refer to technical support on your OMRON website.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed
down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the
actuator rotates or is pushed down.
39
WL-N/WL
Basic Switches
Environment-resistant Switches
Molding Specifications for Hermetic Switches
: Molded parts
WL@-139-N
WL@-140-N
WL@-141-N
Oil seal
Head cap
Airtight
built-in switch
Airtight
built-in switch
Standard
built-in switch
WL@-145-N
WL@-RP40-N
WL@-RP60-N *1
Oil seal
Head cap
Airtight
built-in switch
Airtight
built-in switch
Airtight
built-in switch
*1. Fluorine rubber is used for all rubber parts.
Model
Cable specifications
Standard 5-m VCT cable.
Finished outer diameter: 11.5 mm, 4 conductors.
Connector specifications
WL@-139-N
Resin cap
WL@-140-N
WL@-141-N
WL@-145-N
Metal connector
Standard 5-m VCT cable, with high flexibility and good
anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
WL@-RP40-N
WL@-RP60-N
Resin connector *2
Resin cap
*2. The connector can be removed, so it is possible to use flexible conduit for the cable.
40
WL-N/WL
High-sensitivity and High-precision Switches
Environment-resistant Switches
Mold Specifications for Hermetic Seal Switches
: Molded parts
WLG@-141
WLG@-139
WLG@-140
Oil seal for protection against cutting powder
X-ring
Standard
built-in
switch
Airtight
built-in
switch
Airtight
built-in
switch
WLG@-145
WLG@-RP40
WLG@-RP60 *1
Oil seal for protection against cutting powder
X-ring
O-ring
Airtight
built-in
switch
Airtight
built-in
switch
Airtight
built-in
switch
*1. Fluorine rubber is used for all rubber parts.
Model
WLG@-139
Cable specifications
Standard 5-m VCT cable.
Finished outer diameter: 11.5 mm, 4 conductors.
Connector specifications
Resin cap
WLG@-140
WLG@-141
WLG@-145
Metal connector
Standard 5-m VCT cable, with high flexibility and good
anti-oil properties attached. Finished outer diameter:
11.5 mm, 4 conductors.
WLG@-RP40
WLG@-RP60
Resin connector *2
Resin cap
*2. The connector can be removed, so it is possible to use flexible conduit for the cable.
41
WL-N/WL
Basic Switches
Spatter-prevention Switches: WLCA2-LES-N
Actuator
Roller, Roller Axis
Using stainless steel prevents
spatter from adhering.
Screws
Operating Lever
Externally visible screws on the head and
cover are made of stainless steel to prevent
spatter adherence.
A baking finish is applied to the surface
so that any adhering spatter is easily
removed.
Head Cap
Roller Lever Bolt
Using fluororesin prevents spatter from
adhering.
Stainless steel construction to prevent
spatter adherence.
Double nut models are also available.
* Spatter means the zinc powder produced
when welding.
Adhering spatter to the Limit Switch may
cause malfunction of lever or lamp cover.
The lack of gap prevents spatter
powder from clogging.
High-sensitivity and High-precision Switches
Spatter-prevention Switches: WLG2-LEAS
Actuator
Roller, Roller Axis
Using stainless steel prevents spatter
from adhering.
Screws
Externally visible screws on the head and
cover are made of stainless steel to prevent
spatter adherence.
Operating Lever
A baking finish is applied to the surface so
that any adhering spatter is easily removed.
Head Cap
Using fluororesin prevents spatter from
adhering.
* Spatter means the zinc powder produced
when welding.
Adhering spatter to the Limit Switch may
cause malfunction of lever or lamp cover.
Double Nut
SUS is used for double nut.
Lamp Cover
· Heat-resistant resin is used for the lamp
cover.
· By using spherical surface for the display
part, it disperses the direction of spatter.
The lack of gap prevents spatter
powder from clogging.
42
WL-N/WL
Basic Switches
Long-life Switches: WLMCA2-N
Head Cap
Head
The head cap helps prevent the entry of cutting
chips.You can use the protrusion on the cap to
confirm the set position.
You can remove the two screws to mount the head in
any of the four possible directions.
Actuator
Roller
The roller is made of self-lubricating sintered
Shield Structure
A head cap and oil seal form a double-seal structure.
Excellent durability and reliability are ensured.
stainless steel.
It provides superior resistance to wear.
Lever
The lever is forged from anti-corrosive aluminum
alloy. It provides superior corrosion resistance and
outstanding strength. With a roller lever actuator,
the actuator position can be set anywhere within
360°. (The lever cannot be mounted in the opposite
direction.)
Oil seal
Head cap
Operating Plunger
PEEK resin is used. It provides superior resistance to
wear.You can change the mounting direction to use
any one of the three operating directions (both sides,
left side, or right side).
Built-in Switch
Built-in switch with an
SPST-NO+NC contact form.
Cover Seal
High sealing performance is achieved. The seal also
serves as a spacer.
There is no troublesome insulating paper, making it
easy to work with the Switch.
Terminal Screws
Four, M3.5 screws.
Cover Setscrew
A combination Philips-slotted screw is used.
A retainer prevents the screw from falling
from the cover even when the screw is loose.
Conduit Opening
Cover
In addition to parallel threads for G1/2 tubing,
direct-wired and pre-wired connector types are available.
43
WL-N/WL
High-sensitivity/High-precision Switches
Long-life Switches: WLMG2
Release Plunger
Set Position Marker Plate
Hardening method changed for greater
abrasion resistance.
The set position is easy to view.
The stroke is indicated in fluorescent color that
is visible from the slit in the rubber cap.
Long-life Model
Standard Model
Stainless
steel +
Hardening
Sintered
alloy
Head
The Head can be mounted in any of the
four directions by removing the screws
at the four corners of the Head.
Fluorescent paint
Shaft Section Seal
Requires maintenance (excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
By fitting a double seal consisting of an
oil seal and an X-ring to the rotary
shaft, even greater sealing properties
are achieved.
Requires maintenance (excessive overtravel)
Actuator
Roller
The roller is made of self-lubricating stainless
sintered and boasts high resistance to wear.
Lever
Head
Mounting
Screws
X-ring
Oil seal
Smoother Movement
The lever forged of anti-corrosive aluminium
alloy features high corrosion resistance and
outstanding ruggedness. With roller lever
models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
A grease holder is provided on the
shaft to prevent the grease from
running out.
Standard Model
Operational Plunger *
Cover Seal
By using a packing seal as the
Long-life Model
cover seal, an optimum squeeze
can be obtained and high sealing
properties are assured as well.
Grease holder
Terminal Screws
Four, M4 screws
Smooth movement is achieved using
olefin grease. (Standard models use
molybdenum disulfide grease.)
Cover
Separator
Bearing
The separator has outstanding
insulation properties and prevents
the generation of any gases
which may corrode the internal
parts.
The bearing smooths the plunger
movement.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Cover Mounting Screw
Phillips screws are used to
ensure ease of use.
Conduit Opening
In addition to parallel threads for G½ tubing,
direct-wired and pre-wired connector types are
available.
44
WL-N/WL
Dimensions and Operating Characteristics
(Unit: mm)
General-purpose and Environment-resistant Switches
Standard Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Roller lever R50
WLCA2-N
WLCA2-7-N
WLCA2-2-N
WLCA2-2N-N
60 max.
67.2 max.
1.5
1.5
58.1
41.5
36
53
41.5
40
1.5
1.5
17.5×7 dia. *
17.5×15 dia. *
Two, M3.5
1.5
1.5
25.4
13.1
25.4
13.1
Two, M3.5
12.7
R50
R38
12.7
Four, 5.2 dia.
holes
25.4
68.7
M5
25.4
68.7
Allen-head bolt
14.7
(125)
14.7
(137)
M5
Allen-head bolt
Four, 5.2 dia. holes
0.2
58.7
0.2
58.7
Three, M4
Three, M4
5
5
21.6
Four, M6
Depth: 15 min.
21.6
(4.9)
(4.9)
1.2
29.2
Four, M6
Depth: 15 min
(15.1)
30.2
40
JIS B 0202 G½
(15.1)
1.2
JIS B 0202 G½
29.2
42 max.
0.2
0.2
0.8
30.2
40
42 max.
53.2
53.2
0.7
0.7
0.8
* Stainless sintered roller
* Stainless sintered roller
Roller lever R63
Adjustable roller lever
WLCA2-8-N
WLCA12-N
WLCA12-2-N
WLCA12-2N-N
60 max.
53
1.5
1.5
41.5
40
17.5×7 dia. *
67 max.
60
1.5
17.5×7 dia. *
1.5
1.5
41.5
25.4
25.4
13.1
R63
13.1
Two, M3.5
Two, M3.5
Adjustable range:
25 to 89
12.7
12.7
M5
Allen-head bolt
Four, 5.2 dia.
Four, 5.2 dia. holes
(150)
25.4
68.7
25.4
68.7
M5
Allen-head
bolt
holes
14.7
14.7
0.2
58.7
0.2
Three, M4
Three, M4
58.7
5
5
Four, M6
Depth: 15 min
21.6
(4.9)
21.6
(4.9)
(15.1)
Four, M6
Depth: 15 min
(15.1)
1.2
29.2
1.2
29.2
0.2
30.2
40
JIS B 0202 G½
0.2
42 max.
30.2
40
0.7
JIS B 0202 G½
42 max.
0.8
0.8
65.2
0.7
53.2
* Stainless sintered roller
* Stainless sintered roller
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Model
WLCA2-N
WLCA2-2-N
WLCA2-2N-N
WLCA2-7-N
WLCA2-8-N
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
13.34 N
1.18 N
15 5°
70°
13.34 N
1.18 N
25 5°
60°
13.34 N
1.18 N
20° max.
70°
10.2 N
0.9 N
15 5°
70°
8.04 N
0.71 N
15 5°
70°
12°
16°
10°
12°
12°
Model
WLCA12-N *1
WLCA12-2-N *1
WLCA12-2N-N *1
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
13.34 N
1.18 N
15 5°
70°
13.34 N
1.18 N
25 5°
60°
13.34 N
1.18 N
20° max
70°
12°
16°
10°
* The operating characteristics are measured at the lever length of 38 mm.
45
WL-N/WL
Switches with Roller Lever Actuators
Basic Switches
Adjustable rod lever 25 to 140 mm
Adjustable rod lever
WLCAL4-N
WLCL-N
WLCL-2-N
WLCL-2N-N
67 max.
8
9
3.2 dia. *
12.8
55 max.
1.5
46
1.5
0.2 dia.
54.5
3
(length:160) *
1.5
1.5
41.5
25.4
13.1
41.5
Adjustable range:
350 to 380
25.4
13.1
Adjustable range:
25 to 140
M8
Allen-head
set screw
Two, M3.5
12.7
12.7
65
Four, 5.2 dia.
holes
25.4
68.7
25.4
68.7
M5
Allen-head
set screw
14.7
14.7
M5
Allen-head
set screw
Four, 5.2 dia.
holes
Three, M4
0.2
0.2
58.7
58.7
5
Three, M4
5
(4.9)
Four, M6
Depth: 15 min.
21.6
(4.9)
Four, M6
Depth: 15 min.
21.6
JIS B 0202 G½
(15.1)
(15.1)
1.2
29.2
1.2
0.2
29.2
30.2
0.2
JIS B 0202 G½
30.2
40
42 max.
0.7
42 max.
40
0.7
* Stainless steel rod
* Stainless steel rod
Rod spring lever
WLCAL5-N
67 max.
7.5
2.3 dia. *
2
428.5
1.5
54.5
1.5
41.5
65
25.4
13.1
12.7
Four, 5.2
dia. holes
11
14.7
25.4
M5
Allen-head
bolt
68.7
0.2
58.7
Three, M4
5
(4.9)
21.6
29.2
42 max.
Four, M6
Depth: 15 min.
(15.1)
1.2
JIS B 0202 G½
0.2
30.2
40
0.7
* Piano wire
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Model
WLCL-N *1
WLCL-2-N *1
WLCL-2N-N *1
WLCAL4-N *2
WLCAL5-N
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
1.39 N
0.27 N
15 5°
70°
1.39 N
0.27 N
25 5°
60°
1.39 N
0.27 N
20° max
70°
0.98 N
0.15 N
15 5°
70°
0.9 N
0.09 N
15 5°
70°
12°
16°
10°
12°
12°
Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is
mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring.
*1. The operating characteristics are measured at the lever length of 140 mm.
*2. The operating characteristics are measured at a rod length of 380 mm.
46
WL-N/WL
Switches with Roller Lever Actuators
High-sensitivity Switches
Roller lever R38
Adjustable rod lever 25 to 140 mm
WLG2
WLGL
WL01G2
WL01GL
60 max.
53 1.5
41.5 1.5
40 1.5
9
55 max.
46 1.5
17.5 dia. (length: 7) *
Four, M3.5
13.1
41.5 1.5
13.1
3
0.2 dia.
25.4
(length: 160) *
12.7
25.4
12.7
38R
Adjustable range:
25 to 140
M5 (length: 12)
Four, M3.5
Allen-head bolt
M8 (length: 12)
Allen-head
lock screw
25.4
68.7
14.7
25.4
68.7
(125)
M5 (length: 12)
Allenhead bolt
14.7
Four, 5.2+0.2
dia. holes0
Four, 5.2+0.2
dia. holes0
58.7 0.2
Three, M4
(length: 13)
58.7 0.2
Three, M4
(length: 13)
5
21.6
Four, M6
Depth: 15 min.
5
JIS B0202 G½
Effective thread:
4 threads min.
1.2
21.6
1.2
(15.1)
JIS B0202 G½
Effective thread:
4 threads min.
29.2
(15.1)
Four, M6
Depth: 15 min.
(4.9)
(4.9)
35
29.2
30.2 0.2
40 0.7
30.2 0.2
40 0.7
42 max.
35
53.2 0.8
42 max.
* Stainless sintered roller
* Stainless sintered roller
Adjustable Roller Lever
WLG12
WL01G12
67 max.
60 1.5
41.5 1.5
13.1
17.5 dia. (length: 7) *
Four, M3.5
25.4
12.7
Adjustable range:
25 to 89
M5 (length: 16)
Allen-head
bolt
25.4
68.7
Four, 5.2+0.2
dia. holes0
14.7
58.7 0.2
Three, M4
(length: 13)
5
21.6
1.2 Four, M6
JIS B0202 G½
Effective thread:
4 threads min.
(15.1)
30.2 0.2
40 0.7
29.2
Depth: 15 min.
(4.9)
35
42 max.
65.2 0.8
* Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Switches with High-precision Actuators
Roller lever R38
60 max.
WLGCA2
WL01GCA2
53 1.5
41.5 1.5
40 1.5
13.1
17.5 dia. (length: 7) *
25.4
12.7
Four, M3.5
38R
M5 (length: 12)
Allen-head bolt
25.4
14.7
(125)
Four, 5.2+0.2
dia. holes0
68.7
58.7 0.2
Three, M4
(length: 13)
5
21.6
1.2
29.2
JIS B0202 G½
Effective thread:
4 threads min.
Four, M6
Depth: 15 min.
(15.1)
30.2 0.2
40 0.7
(4.9)
35
42 max.
53.2 0.8
* Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model
WLG2
WLG12 *1
WLGL *2
WLGCA2
WL01G2
WL01G12 *1
WL01GL *2
WL01GCA2
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
9.81 N
9.81 N
2.84 N
13.34 N
1.47 N
0.98 N
0.98 N
0.25 N
+2°
+2°
+2°
10°
10°
10°
5° +2°
−1°
−1°
−1°
0°
65°
7°
65°
7°
65°
7°
40°
3°
*1. The operating characteristics are measured at the lever length of 38 mm.
*2. The operating characteristics are measured at a rod length of 140 mm.
47
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Sealed top plunger
Horizontal plunger
WLSD-N
OP
46.6
PT
0.8
13.1
12.9
10 dia.
13.1
12.7
WLD18-N
25.4
Two, M3.5
PT
R1 *
25 dia. *2
R1
Two, M3.5
OP
27.5
17.8
9.3 dia. *1
(96.2)
Four, 5.2 dia. holes
Four, 5.2 dia. holes
0.2
0.2
58.7
58.7
68.7
68.7
Three, M4
Three, M4
5
5
*1. Stainless steel plunger
*2. Cosmetic nuts
21.6
21.6
(15.1)
30.2
Four, M6
Depth: 15 min
(15.1)
30.2
Four, M6
Depth: 15 min
JIS B 0202 G
½
JIS B 0202 G
½
(4.9)
(4.9)
* Stainless steel plunger
0.2
0.2
1.2
1.2
29.2
29.2
0.7
42 max.
0.7
42 max.
40
40
Sealed top-roller plunger
Horizontal-roller plunger
WLSD2-N
13.1
12.9
PT
Two, M3.5
25 dia. *2
OP
55.7
WLD28-N
14.3 dia.×5
*
0.8
13.1
12.7
25.4
PT
Two, M3.5
OP
27.5
17.8
17 dia.×4.6 *1
(96.2)
58.7
Four, 5.2 dia. holes
Four, 5.2 dia. holes
0.2
0.2
58.7
68.7
68.7
Three, M4
Three, M4
5
5
21.6
21.6
(15.1)
30.2
*1. Stainless sintered roller
*2. Cosmetic nuts
(15.1)
30.2
Four, M6
Depth: 15 min
Four, M6
Depth: 15 min
JIS B 0202 G
½
JIS B 0202 G½
(4.9)
(4.9)
*Stainless sintered roller
0.2
0.2
1.2
1.2
29.2
29.2
0.7
42 max.
0.7
42 max.
40
40
Sealed top-ball plunger
Horizontal-ball plunger
WLSD3-N
PT
Two, M3.5
25 dia.
OP
46.6
13.1
12.9
15.5 dia.
0.8
WLD38-N
PT
1/2" dia. *
13.1
12.7
25.4
*2
Two, M3.5
OP
15.5 dia.
1/2" dia.
27.5
17.8
*1
(96.2)
Four, 5.2 dia. holes
Four, 5.2 dia. holes
0.2
58.7
0.2
68.7
58.7
68.7
Three, M4
Three, M4
5
5
*
*
1. Stainless steel ball
2. Cosmetic nuts
21.6
(15.1)
30.2
Four, M6
Depth: 15 min
21.6
JIS B0202 G
½
(15.1)
30.2
Four, M6
Depth: 15 min
(4.9)
* Stainless steel ball
JIS B0202 G
½
0.2
0.7
1.2
(4.9)
29.2
0.2
1.2
29.2
42 max.
0.7
42 max.
40
40
Top-roller plunger
13.1
12.9
17 dia.×4.6
*
WLD2-N
PT
Four, M3.5
OP
28.4
68.7
Four, 5.2 dia. holes
0.2
58.7
5
Three, M4
*Stainless sintered roller
21.6
Four, M6
Depth: 15 min
JIS B0202 G
½
(15.1)
30.2
(4.9)
1.2
29.2
0.2
42 max.
0.7
40
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Model
WLD18-N
WLD28-N
WLD38-N
WLD2-N
WLSD-N
WLSD2-N
WLSD3-N
Operating characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential MD
OF
max.
min.
max.
min.
max.
26.67 N
8.92 N
1.7 mm
6.4 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
4 mm
RF
PT
OT
1 mm
Operating position
Total travel position
OP
TTP
34 0.8 mm
29.5 mm
44 0.8 mm
39.5 mm
44.5 0.8 mm
41 mm
44 0.8 mm
39.5 mm
40.6 0.8 mm
54.2 0.8 mm
54.1 0.8 mm
max.
---
---
---
48
WL-N/WL
Switches with Flexible Rod Actuators
Basic Switches
Coil spring
Coil Spring (Multi-wire)
WLNJ-30-N
WLNJ-N
* 1
* 1
PT
PT
6.5 dia.
4.8 dia.
* 3
* 3
* 2
* 2
(107)
(107)
2.5
140
2.5
140
13.1
12.9
13.1
12.9
Two, M3.5
Two, M3.5
0.8
33.7
0.8
33.7
0.2
Four, 5.2 dia. holes
Four, 5.2 dia. holes
0.2
58.7
5
68.7
58.7
5
68.7
Three, M4
Three, M4
21.6
(15.1)
30.2
Four, M6
Depth: 15 min
JIS B 0202 G
½
(4.9)
21.6
(15.1)
30.2
Four, M6
Depth: 15 min
0.2
0.7
1.2
29.2
42 max.
JIS B 0202 G
½
(4.9)
0.2
1.2
29.2
40
0.7
42 max.
40
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
*1. Do not operate the Switch in the direction of the axial center.
*2. Piano wire coil spring.
*3. The range for operation is 1/3rd of the overall spring length from the end of the spring.
Resin rod
Steel wire
* 1
WLNJ-2-N
* 1
WLNJ-S2-N
1 dia
PT
PT
8 dia.
* 3
* 3
* 2
(95.4)
(159)
* 2
2.5
140
2.5
193
13.1
12.9
26 dia.
13.1
12.9
Two, M3.5
0.8
Two, M3.5
44.6
0.8
33.7
Four, 5.2 dia. holes
Four, 5.2 dia. holes
0.2
58.7
5
68.7
0.2
58.7
5
68.7
Three, M4
Three, M4
21.6
(15.1)
30.2
Four, M6
Depth: 15 min
JIS B0202 G
½
(4.9)
21.6
(15.1)
30.2
Four, M6
Depth: 15 min
0.2
0.7
1.2
JIS B 0202 G
½
29.2
(4.9)
0.2
1.2
29.2
42 max.
42 max.
40
0.7
40
*1. Do not operate the Switch in the direction of the axial center.
*2. Stainless steel wire.
*1. Do not operate the Switch in the direction of the axial center.
*2. Polyamide Resin Rod
*3. The range for operation is 1/3rd of the overall wire length from the end of the wire.
*3. The range for operation is 1/3rd of the overall rod length from the end of the rod.
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Model
WLNJ-N
WLNJ-30-N
WLNJ-2-N
WLNJ-S2-N
Operating characteristics
Operating force
Pretravel
OF
PT
max.
1.47 N
20 10 mm
1.47 N
20 10 mm
1.47 N
40 20 mm
0.28 N
40 20 mm
* These values are for the top end of the spring, rod, or wire.
49
WL-N/WL
Switches with Fork Lock Lever Actuators
Retention Switches
General-purpose
The WLCA32-41-N is shown in the following
diagram.
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-44-N
62.5 max.
3.5
56.4
3.5
Two, 17.5×7 dia. *
42.8
25.4
13.1
12.7
3°
90°
R38
Two, M3.5
34.1
14.7
M5 Allen-head
set screw
(125)
Four, 5.2 dia.
holes
Three, M4
0.2
58.7
5
68.7
(15.1)
(4.9)
21.6
4-M6
Four, M6
Depth: 15 min.
JIS B 0202 G½
1.2
0.2
29.2
30.2
0.7
40
42 max.
* Plastic Roller
(The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.)
Note: 1. Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Model
WLCA32-41 to 44-N
Operating characteristics
Force necessary to reverse the direction of the lever max.
Movement until the lever reverses
11.77N
50 5°
55°
Movement until switch operation
Movement after switch operation
max.
min.
35°
Operation indicator Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
General-purpose Models
WLCA2-LD-N
WLCA2-LE-N
60 max.
1.5
53
17.5×7 dia. *
Two, M3.5
1.5
41.5
40
1.5
25.4
13.1
12.7
R38
Four, 5.2 dia. holes
25.4
68.7
14.7
M5
(125)
Allen-head bolt
0.2
58.7
Three, M4
5
21.6
(4.9)
1.5
JIS B 0202 G½
29.2
(15.1)
Four, M6
Depth: 15 min
42 max.
0.2
30.2
40
0.8
53.2
0.7
* Stainless sintered roller
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Operating characteristics
Basic models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
13.34 N
1.18 N
15 5°
70°
12°
50
WL-N/WL
Sensor I/O Connector Switches
(For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 22.)
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Roller lever R38
60 max.
Pre-wired Connector type
WLCA2-LD-M1J-N
1.5
53
Direct-wire Connector type
WLCA2-LDK13-N
1.5
41.5
40
17.5×7 dia. *
1.5
25.4
13.1
60 max.
1.5
53
41.5
40
17.5×7 dia. *
1.5
Two, M3.5
Four, 5.2 dia. holes
12.7
1.5
R38
25.4
13.1
25.4
68.7
Two, M3.5
12.7
M5
14.7
R38
Allen-head bolt
(125)
Four, 5.2 dia. holes
25.4
68.7
M5
Allen-head
bolt
14.7
0.2
58.7
Three, M4
(125)
58.7
0.2
5
Three, M4
(4.9)
(15.1)
Four, M6
Depth: 15 min
5
SC-1M
12.5
+100
−50
(4.9)
Four, M6
Depth: 15 min.
300
1.2
(15.1)
29.2
42 max.
0.2
30.2
40
M12×1
0.8
53.2
0.7
XS2H-D421
1.2
29.2
* Stainless sintered roller
0.2
30.2
40
42 max.
0.7
0.8
53.2
* Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
Operating characteristics
Basic models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
13.34 N
1.18 N
15 5°
70°
12°
High-sensitivity and High-precision Switches
Roller lever R38
60 max.
53
Roller lever R38
41.15.5 1.5
60 max.
Direct-wire Connector type
High-sensitivity
Pre-wired Connector type
High-sensitivity
WLG2
40 1.5
17.5 dia. (length: 7) *
53 1.5
13.1
41.5 1.5
25.4
12.7
WLG2
High-precision
WLGCA2
40 1.5
Four, M3.5
13.1
17.5 dia. (length: 7) *
Four, M3.5
38R
High-precision
25.4
12.7
WLGCA2
25.4
M5 (length: 12)
Allen-head bolt
14.7
38R
Four, 5.2+0.2
25.4
dia. holes0
M5 (length: 12)
Allen-head bolt
14.7
68.7
58.7 0.2
Three, M4
(length: 13)
Four, 5.2+0.2
dia. holes0
5
68.7
58.7 0.2
Three, M4
(length: 13)
(20)
Four, M6
Depth: 15 min.
5
12.5
SC-1M
Four, M6
Depth: 15 min.
21.6
+100
M12 × 1
300
-50
1.2
(15.1)
30.2 0.2
40 0.7
(4.9)
29.2
JIS B0202 G½
Effective thread:
4 threads min.
35
42 max.
53.2 0.8
6 dia.
* Stainless sintered roller
21.6
1.2
XS2H-D421
(15.1)
(4.9)
29.2
35
30.2 0.2
40 0.7
M12 × 1
42 max.
53.2 0.8
* Stainless sintered roller
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Operating characteristics
High-sensitivity
High-precision Models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
9.81 N
13.34 N
1.47 N
0.98 N
+2°
10°
5°+2°
−1°
0°
65°
7°
40°
3°
51
WL-N/WL
Spatter-prevention Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Roller lever R38
Screw terminal type
WLCA2-@S-N
Pre-wired Connector type
WLCA2-@S-M1J-1-N
60 max.
60 max.
1.5
1.5
53
53
1.5
17.5×7 dia. *
Two, M3.5
1.5
41.5
40
41.5
40
17.5×7 dia. *
1.5
1.5
25.4
13.1
25.4
13.1
Two, M3.5
12.7
12.7
R38
R38
Four, 5.2 dia. holes
Four, 5.2 dia. holes
25.4
68.7
25.4
68.7
14.7
M5
M5
14.7
(125)
Allen-head bolt
(125)
Allen-head bolt
Fluorine
resin cap
Fluorine
resin cap
0.2
58.7
0.2
58.7
Three, M4
Three, M4
5
5
(4.9)
21.6
(4.9)
(15.1)
Four, M6
Depth: 15 min
(15.1)
JIS B 0202 G½
Four, M6
Depth: 15 min
1.2
29.2
0.2
30.2
40
42 max.
0.7
SC-1M
0.8
53.2
+100
−50
* Stainless sintered roller
300
XS2H-D421
1.2
29.2
0.2
30.2
40
42 max.
0.7
0.8
53.2
* Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
High-sensitivity/High-precision Switches
Roller lever R38
Roller lever R38
Screw terminal type
WLG2-@S
WLGCA2-@S
Pre-wired Connector type
WLG2-@S-M1J *
WLGCA2-@S-M1J *
* External dimensions are the same even for different core wires.
60 max.
53 1.5
41.5 1.5
60 max.
54 1.5
40 1.5
17.5 dia. (length: 7) *
13.1
17.5 dia. (length: 7) *
Four, M3.5
13.1
Four, M3.5
head clamping screws
Two, M5 Allen-head nut
and arm set screw
25.4
12.7
25.4
12.7
head clamping screws
38R
Two, M5 Allen-head nut
and arm set screw
38R
25.4
Four, 5.2+0.2
dia. holes0
25.4
Four, 5.2+0.2
dia. holes0
14.7
14.7
Fluororesin cap
(125)
Fluororesin cap
Three, M4
(length: 13)
68.7
58.7 0.2
68.7
58.7 0.2
Lamp cover
Lamp cover
5
5
Three, M4
(length: 13)
(20)
Four, M6
Depth: 15 min.
21.6
1.2
29.2
Four, M6
Depth: 15 min.
(15.1)
30.2 0.2
40 0.7
JIS B0202 G½
Effective thread:
4 threads min.
(4.9)
SC-1M
35
300 +100
−50
42 max.
* Stainless steel roller
6 dia.
21.6
1.2
XS2H-D421
(15.1)
(4.9)
29.2
30.2 0.2
40 0.7
35
42 max.
53.2 0.8
* Stainless steel roller
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Operating characteristics
Basic models
High-sensitivity
High-precision Models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
13.34 N
1.18 N
15 5°
70°
9.81 N
13.34 N
1.47 N
0.98 N
+2°
10°
5° +2°
−1°
0°
65°
7°
40°
3°
12°
52
WL-N/WL
Switches with Plunger Actuators
Basic Switches
Sealed top-roller plunger
Sealed top-roller plunger
Pre-wired Connector type
WLD28-@S-M1J-1-N
Screw terminal type
WLD28-@S-N
13.1
12.9
13.1
12.9
PT
14.3 dia.×5 *
Rubber cap
(fluorine rubber)
14.3 dia.×5 *
PT
Rubber cap
(fluorine rubber)
Two, M3.5
OP
Two, M3.5
OP
Four, 5.2 dia. holes
Four, 5.2 dia. holes
0.2
58.7
5
68.7
0.2
58.7
68.7
Three, M4
Three, M4
5
(15.1)
(4.9)
Four, M6
Depth: 15 min
21.6
Four, M6
Depth: 15 min
JIS B 0202 G
½
SC-1M
0.2
0.7
1.2
29.2
30.2
40
42 max.
+100
−50
300
*Stainless sintered roller
XS2H-D421
(15.1)
(4.9)
1.2
29.2
42 max.
0.2
0.7
30.2
40
*Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
Operating characteristics
Basic models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
16.67 N
4.41 N
1.7 mm max.
5.6 mm
1 mm
Operating force
Pretravel
OF max.
PT
44 0.8 mm
39.5 mm
53
WL-N/WL
Long-life Switches
Switches with Roller Lever Actuators
Basic Switches
Roller lever R38
Roller lever R38
Screw terminal type
WLMCA2-LD-N
Direct-wire Connector type
WLMCA2-LDK13-N
60 max.
53
60 max.
53
1.5
1.5
1.5
1.5
1.5
41.5
40
41.5
40
1.5
17.5 dia.×7 *
17.5 dia.×7
*
25.4
25.4
13.1
12.7
13.1
12.7
Two, M3.5
Two, M3.5
R38
R38
Four, 5.2 dia. holes
Four, 5.2 dia. holes
25.4
68.7
25.4
68.7
14.7
58.7
14.7
M5 Allen-head bolt
Fluorine resin cap
M5 Allen-head bolt
Fluorine resin cap
0.2
0.2
58.7
5
Three, M4
Three, M4
5
12.5
21.6
(15.1)
(4.9)
Four, M6
Depth: 15 min
Four, M6
Depth: 15 min
(15.1)
(4.9)
M12×1
1.2
0.2
1.2
29.2
29.2
30.2
JIS B 0202 G
½
0.7
0.2
0.7
42 max.
42 max.
40
30.2
40
0.8
0.8
53.2
53.2
*Stainless sintered roller
*Stainless sintered roller
Roller lever R38
Pre-wired Connector type
WLMCA2-LD-M1J-N
60 max.
53
1.5
1.5
41.5
1.5
40
17.5 dia.×7 *
25.4
13.1
12.7
R38
Two, M3.5
Four, 5.2 dia. holes
25.4
68.7
14.7
M5 Allen-head bolt
Fluorine resin cap
0.2
58.7
Three, M4
5
Four, M6
Depth: 15 min
SC-1M
+100
300
−50
XS2H-D421
(15.1)
(4.9)
1.2
29.2
0.2
42 max.
30.2
0.7
40
0.8
53.2
*Stainless sintered roller
Note: 1. Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
2. The models with operation indicators are shown in the above diagrams.
Operating characteristics
Basic models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
13.34 N
1.18 N
15 5°
70°
12°
54
WL-N/WL
Switches with Roller Lever Actuators
High-sensitivity and High-precision Switches
Roller lever R38
Roller lever R38
60 max.
60 max.
53 1.5
Screw terminal type
WLMG@-LD
Direct-wire Connector type
WLMG@-LD@
53 1.5
41.5 1.5
40 1.5
41.5 1.5
40 1.5
13.1
13.1
17.5 dia. (length: 7) *
17.5 dia. (length: 7) *
Four, M3.5
(length: 26.5)
25.4
12.7
25.4
12.7
Four, M3.5
(length: 26.5)
M5 (length: 12)
Allen-head bolt
38R
38R
M5 (length: 12)
Allen-head bolt
Four, 5.2+0.2
25.4
68.7
25.4
68.7
Four, 5.2+0.2
dia. holes0
dia. holes0
14.7
14.7
Rubber cap
Rubber cap
58.7 0.2
58.7 0.2
Three, M4
(length: 13)
Three, M4
(length: 13)
Lamp cover
5
12.5
Lamp cover
5
21.6
1.2
29.2
Four, M6
Depth: 15 min.
Four, M6
Depth: 15 min.
SC-2FD
(15.1)
30.2 0.2
40 0.7
21.6
1.2
(4.9)
(15.1)
30.2 0.2
40 0.7
JIS B0202 G½
Effective thread:
4 threads min.
35
42 max.
53.2 0.8
(4.9)
29.2
x
M12
1
35
42 max.
53.2 0.8
* Stainless sintered roller
JIS B0202 G½
Effective thread:
4 threads min.
* Stainless sintered roller
Roller lever R38
Pre-wired Connector type
WLMG@-LD@
60 max.
53 1.5
41.5 1.5
40 1.5
13.1
17.5 dia. (length: 7) *
Four, M3.5
(length: 26.5)
25.4
12.7
M5 (length: 12)
Allen-head bolt
38R
Four, 5.2+0.2
25.4
68.7
dia. holes0
14.7
Rubber cap
Three, M4
(length: 13)
58.7 0.2
Lamp cover
(20)
5
Four, M6
Depth: 15 min.
XS2H-D421
+100
-50
300
44.7
6 dia.
21.6
1.2
(15.1)
(4.9)
29.2
30.2 0.2
40 0.7
35
42 max.
53.2 0.8
* Stainless sintered roller
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
Operating characteristics
High-sensitivity
High-precision Models
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
9.81 N
13.34 N
1.47 N
0.98 N
+2°
10°
5°+2°
−1°
0°
65°
7°
40°
3°
55
WL-N/WL
Actuators (Levers Only)
Lever: Only rotating lever models are illustrated.
WL-1A100
WL-1A115
WL-1A400
WL-1A118
Standard Lever
Resin Roller
Bearing Roller
Nylon Roller:
Roller Width: 30 mm
17.5 dia. (length: 30)
0.8
40.2
17.9
12.6
17.9
12.6
16.9
12.1
17.5 dia. × 7,
sintered stainless steel roller
17 dia. (length: 6)
bearing roller
17.5 dia. (length: 7)
resin roller
Nylon roller
23.6
7.3-dia.
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
mounting
38
54.8
38 54.8
holes
38 54.8
38 54.8
7.3-dia.
mounting
holes
M5
Allen-head bolt
M5
M5
Allen-head bolt
M5
16
16
16
16
11.4
Allen-head bolt
Allen-head bolt
11.4
11.4
11.4
WL-1A105
WL-1A103S
WL-1A200
WL-1A300
Double Nuts
Spatter Prevention
Lever Length: 50
Roller Width: 15
Lever Length: 63
17.9
12.6
17.5 dia. × 15,
sintered stainless steel roller
17.9
12.6
17.9
12.6
17.5 dia. (length: 7)
stainless steel roller
17.5 dia. × 7,
sintered stainless steel roller
17.5 dia. × 7,
sintered stainless steel roller
25.7
16.6
7.3-dia.
7.3-dia.
mounting
mounting
7.3-dia.
mounting
38 54.8
holes
38 54.8
holes
50 66.8
7.3-dia.
mounting
holes
63 79.8
holes
M5
Two, M5
Allenhead nut
and arm set screw
16
16
Allen-head bolt
11.4
11.4
M5
Allen-head bolt
16
11.4
M5
Allen-head bolt
16
11.4
WL-2A100
WL-2A111
WL-2A107
WL-2A108
Resin Roller
Double Nuts
Resin Roller
0.8
0.8
24.9
19.7
0.8
0.8
0.8
17.5 dia. × 7,
steel roller
24.9
19.7
24.9
17.5 dia. × 7,
sintered stainless steel roller
17.5 dia. (length: 7)
resin roller
M5
Allen-head
bolt
0.8
0.8
17.5 dia. (length: 7)
resin roller
24.9
19.7
sintered stainless M5
0.8
19.7
Allen-head
bolt
Adjustable lever:
stainless steel
Adjustable lever:
stainless steel
Adjustable lever:
stainless steel
Adjustable lever:
stainless steel
23
23
23
Adjustable
range:
25 to 140
23
Adjustable
range:
25 to 89
105.75
Adjustable
range:
25 to 89
Adjustable
range:
25 to 89
105.75
M5
105.75
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
155.75
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
M5
Allen-head
Allen-head
bolt
bolt
12
16
12
16
Two, M5 Allen-head nut
and arm set screw
12
16
6.2
(15.8)
WL-2A122
WL-2A106
WL-2A130
WL-2A104
0.8
0.8
0.8
0.8
0.8
0.8
0.8
17.5 dia. × 7,
sintered stainless
steel roller
24.9
19.7
24.9
19.7
24.9
24.7
M5
Allen-head
bolt
17.5 dia. × 7,
sintered stainless
steel roller
17.5 dia. × 7,
sintered stainless
steel roller
50 dia. (length: 6)
Nylon roller
0.8
19.5
19.7
9.1
3
Adjustable lever:
stainless steel
Adjustable lever:
stainless steel
23
(21.8)
(10)
Adjustable
range:
25 to 140
23
Adjustable
range:
25 to 89
R89.5
Three, 5.3+0.2
Adjustable
from 42 to 89
(10)
7.3-dia.
mounting
holes
105.75
M5
(112)
0
155.75
dia. holes
7.3 dia.
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
mounting holes
M5
Allen-head
bolt
Allen-head
bolt
M5
Allen-head bolt
15.9
20
16
20
23
23
12
16
*
Can be installed
on the rear side.
6.2
(15.8)
Note: Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
56
WL-N/WL
Lever: Only rotating lever models are illustrated.
WL-2A110 WL-2A105
WL-1A106
WL-1A110
34.2
24.2
34.5
24.4
35 dia. (length: 6)
Nylon roller
50 dia. (length: 6)
Nylon roller
0.8
49 dia. rubber roller
Material: NBR
0.8
20.1
20.1
50 dia. (length: 15)
Nylon roller
6
R38
R38
23
23
Adjustable
Adjustable
from 41 to
78.5
122
from 41 to
89
M5
Allen-head
M5
Allen-head
bolt
7.3 dia.
mounting
holes
16
7.3-dia.
mounting
holes
bolt
11.5
16
11.5
M5
Allen-head
bolt
M5
Allen-head
bolt
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
16
16
WL-4A100
WL-4A201
WL-3A100
WL-3A106
Double Nut
9
3.2-dia.
stainless
steel rod
9
3.2-dia.
stainless steel rod
2-dia. stainless
steel for spring
3-dia. stainless
steel rod
7.3-dia. mounting
holes
M5
Adjustable
from 350
to 380
Adjustable
from 350
to 380
M5
Allen-head
bolt
7.3-dia.
13
Adjustable
from
25 to 140
mounting holes
Adjustable
from 270 to
290
Allen-head
bolt
8
8
2
400
2
400
160
M5
Allen-head
bolt
19
Actuator's
center of
rotation
M8
Allen-head
set screw
2
65
2
65
11
M8
Allen-head
set screw
11
7.5
7.5
6
6
11
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
Two, M5
Allenhead
nut and arm
set screw
11
M5
Allen-head
bolt
13.4
25.5 max.
13.4
25.5 max.
12.8
12.8
WL-3A108
WL-3A200
WL-3A203
WL-4A112
2.3-dia.
operation rod
9
8 dia.
Cap
3.2-dia.
stainless steel rod
4-dia. stainless
steel rod
50
7.3-dia.
mounting holes
Adjustable
from 650
to 660
M5
Allen-head
bolt
Adjustable
up to 141
2
417.5
8
2
437.5
Adhesive
4
0.4
450
680
1.5
160
4
470
12.5 dia. max.
11
19
12.5
dia.
max.
2.3 dia.
rod
(95)
2
65
11
(95)
M8
Allen-head
set screw
7.5
7.5
6
11
7.5
6
6
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
11
M5
M5
Allen-head
13
13.4
7.5
12.8
Allen-head
7.3-dia.
mounting
holes
M5
bolt
bolt
13
24.6 max.
25.5 max.
Allen-head
bolt
7.5
24.6 max.
WL-2A129
WL-5A101
WL-5A103
WL-5A105
15.8
Two, 17.5 dia. × 7,
sintered stainless steel rollers
Two, 17.5 dia. × 7,
sintered stainless steel rollers
Two, 17.5 dia. × 7,
sintered stainless steel rollers
6.7
17.7
17.7
12.4
3
17.7
12.4
Marking
(18.5)
6.7
1.3
R8
12.4
1.3
90°
90°
90°
Three, 5.2
dia. holes
7.3 dia.
R38
7.3 dia.
7.3 dia.
R38
R38
54.8
84
95.3
54.8
54.8
7.3 dia.
mounting
hole
(108)
10
10
M5 Allen-head
bolt
M5 Allen-head
bolt
M5 Allen-head
bolt
11
11
11
11.3
M5
Allen-head
bolt
15.9
20
WL-5A104 has a plastic roller
WL-5A100 has a plastic roller
WL-5A102 has a plastic roller
22.1
Note: 1. Unless otherwise indicated, a tolerance of 0.4 mm applies to all dimensions.
2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards.
Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur.
57
WL-N/WL
Model Replacement Table (Replacing WL Basic Models with WL-N Basic Models)
Manufacturing of the basic WL models is scheduled to be discontinued. Use the following table to find the corresponding WL-N-series models and
order them instead.
WL
WL-N
WL
WLD3-LD
WL-N
WL
WL-N
WLCA2-N
WLNJ
WLNJ-N
WLNJ-N
WLD38-LD-N
WLCA2
WL01NJ
WLNJ-30
WLD28-LE
WLD28-LE-N
WL01CA2
WLH2
WLCA2-N
WLNJ-30-N
WLD28-LD
WLD28-LD-N
WLCA2-N
WL01NJ-30
WLNJ-2
WLNJ-30-N
WLSD-LE
WLSD-LE-N
WL01H2
WLCA2-N
WLNJ-2-N
WLSD-LD
WLSD-LD-N
WLCA2-2
WL01CA2-2
WLCA2-2N
WL01CA2-2N
WLCA2-7
WL01CA2-7
WLCA2-8
WL01CA2-8
WLCA12
WLCA2-2-N
WLCA2-2-N
WLCA2-2N-N
WLCA2-2N-N
WLCA2-7-N
WLCA2-7-N
WLCA2-8-N
WLCA2-8-N
WLCA12-N
WLCA12-N
WLCA12-N
WLCA12-N
WLCA12-2-N
WLCA12-2-N
WLCA12-2N-N
WLCA12-2N-N
WLCL-N
WL01NJ-2
WLNJ-2-N
WLSD2-LE
WLSD2-LE-N
WLNJ-S2
WLNJ-S2-N
WLSD2-LD
WLSD2-LD-N
WL01NJ-S2
WLCA2-LE
WLCA2-LD
WLH2-LE
WLNJ-S2-N
WLSD3-LE
WLSD3-LE-N
WLCA2-LE-N
WLCA2-LD-N
WLCA2-LE-N
WLCA2-LD-N
WLCA2-2LE-N
WLCA2-2LD-N
WLCA2-2NLE-N
WLCA2-2NLD-N
WLCA2-7LE-N
WLCA2-7LD-N
WLCA2-8LE-N
WLCA2-8LD-N
WLCA12-LE-N
WLCA12-LD-N
WLCA12-LE-N
WLCA12-LD-N
WLCA12-2LE-N
WLCA12-2LD-N
WLCA12-2NLE-N
WLCA12-2NLD-N
WLCL-LE-N
WLSD3-LD
WLSD3-LD-N
WLNJ-LE
WLNJ-LE-N
WLNJ-LD
WLNJ-LD-N
WLH2-LD
WLNJ-30LE
WLNJ-30LE-N
WLCA2-2LE
WLCA2-2LD
WLCA2-2NLE
WLCA2-2NLD
WLCA2-7LE
WLCA2-7LD
WLCA2-8LE
WLCA2-8LD
WLCA12-LE
WLCA12-LD
WLH12-LE
WLH12-LD
WLCA12-2LE
WLCA12-2LD
WLCA12-2NLE
WLCA12-2NLD
WLCL-LE
WLNJ-30LD
WLNJ-30LD-N
WLNJ-2LE
WLNJ-2LE-N
WL01CA12
WLH12
WLNJ-2LD
WLNJ-2LD-N
WLNJ-S2LE
WLNJ-S2LE-N
WL01H12
WLCA12-2
WL01CA12-2
WLCA12-2N
WL01CA12-2N
WLCL
WLNJ-S2LD
WLNJ-S2LD-N
WLCA2-LDK13
WLCA2-55LDK13
WLCA2-LDK43
WLCA2-55LDK43
WLD2-LDK13
WLD2-55LDK13
WLD2-LDK43
WLD2-55LDK43
WLH2-LDK13
WLH2-55LDK13
WLH2-LDK43
WLH2-55LDK43
WLCA2-55LD-M1J
WLCA2-LD-M1GJ
WLCA2-55LD-M1GJ
WLCA2-55LD-M1JB
WLCA2-LD-DGJ03
WLCA2-55LD-DGJ03
WLCA2-LD-DK1EJ03
WLCA2-55LD-DK1EJ03
WLD2-LD-M1J
WLD2-55LD-M1J
WLD2-LD-M1GJ
WLD2-55LD-M1GJ
WLD2-55LD-M1JB
WLD2-LD-DGJ03
WLD2-LD-DK1EJ03
WLD2-55LD-DK1EJ03
WLH2-LD-M1J
WLH2-LD-M1GJ
WLH2-LD-DGJ03
WLCA2-55
WLCA2-LDK13-N
WLCA2-55LDK13-N
WLCA2-LDK43-N
WLCA2-55LDK43-N
WLD28-LDK13-N
WLD28-55LDK13-N
WLD28-LDK43-N
WLD28-55LDK43-N
WLCA2-LDK13-N
WLCA2-55LDK13-N
WLCA2-LDK43-N
WLCA2-55LDK43-N
WLCA2-55LD-M1J-N
WLCA2-LD-M1GJ-N
WLCA2-55LD-M1GJ-N
WLCA2-55LD-M1JB-N
WLCA2-LD-DGJ-N
WLCA2-55LD-DGJ-N
WLCA2-LD-DK1EJ-N
WLCA2-55LD-DK1EJ-N
WLD28-LD-M1J-N
WLD28-55LD-M1J-N
WLD28-LD-M1GJ-N
WLD28-55LD-M1GJ-N
WLD28-55LD-M1JB-N
WLD28-LD-DGJ-N
WLD28-LD-DK1EJ-N
WLD28-55LD-DK1EJ-N
WLCA2-LD-M1J-N
WLCA2-LD-M1GJ-N
WLCA2-LD-DGJ-N
WLCA2-55-N
WL01CL
WLCL-N
WLHL
WLCL-2N-N
WLCL-2N-N
WLCL-2-N
WLCL-2N-N
WLCL-2N-N
WLCAL4-N
WLCAL5-N
WLCA32-41-N
WLCA32-41-N
WLCA32-42-N
WLCA32-43-N
WLCA32-43-N
WLCA32-44-N
WLCA32-44-N
WLD18-N
WL01HL
WLCL-2
WLCL-2N
WL01CL-2N
WLHAL4
WLHAL5
WLCL-LD
WLCL-LD-N
WLCA32-41
WL01CA32-41
WLCA32-42
WLCA32-43
WL01CA32-43
WLCA32-44
WL01CA32-44
WLD
WLHL-LE
WLCL-2NLE-N
WLCL-2NLD-N
WLCL-2LE-N
WLCL-2LD-N
WLCL-2NLE-N
WLCL-2NLD-N
WLCAL4-LE-N
WLCAL4-LD-N
WLCAL5-LE-N
WLCAL5-LD-N
WLCA32-41LE-N
WLCA32-41LD-N
WLCA32-42LE-N
WLCA32-43LE-N
WLCA32-43LD-N
WLD18-LE-N
WLD18-LD-N
WLD28-LE-N
WLD28-LD-N
WLD38-LE-N
WLHL-LD
WLCL-2LE
WLCL-2LD
WLCL-2NLE
WLCL-2NLD
WLHAL4-LE
WLHAL4-LD
WLHAL5-LE
WLHAL5-LD
WLCA32-41LE
WLCA32-41LD
WLCA32-42LE
WLCA32-43LE
WLCA32-43LD
WLD-LE
WL01D
WLD18-N
WLD2
WLD28-N
WL01D2
WLD28-N
WLD3
WLD38-N
WL01D3
WLD38-N
WLD28
WLD28-N
WL01D28
WLSD
WLD28-N
WLSD-N
WL01SD
WLSD-N
WLD-LD
WLSD2
WLSD2-N
WLD2-LE
WL01SD2
WLSD3
WLSD2-N
WLD2-LD
WLSD3-N
WLD3-LE
WLCA2-55LD
WLCA2-55LD-N
WL01SD3
WLSD3-N
58
WL-N/WL
WL
WLCA2-55LE
WLCA2-139
WL-N
WL
WLCA12-RP60
WLCA12-TH
WLCA12-TC
WLCA12-RP
WLCA12-P1
WLH12-TH
WLH12-TC
WLH12-RP
WLH12-P1
WLCA12-2TH
WLCA12-2TC
WLCA12-2NTH
WLCA12-2NTC
WLCL-55
WL-N
WLCA12-RP60-N
WLCA12-TH-N
WLCA12-TC-N
WLCA12-RP-N
WLCA12-P1-N
WLCA12-TH-N
WLCA12-TC-N
WLCA12-RP-N
WLCA12-P1-N
WLCA12-2TH-N
WLCA12-2TC-N
WLCA12-2NTH-N
WLCA12-2NTC-N
WLCL-55-N
WL
WLSD-TH
WL-N
WLCA2-55LE-N
WLCA2-139-N
WLSD-TH-N
WLSD-TC
WLSD-TC-N
WLCA2-139LD2
WLCA2-139LD3
WLCA2-140
WLCA2-139LD2-N
WLCA2-139LD3-N
WLCA2-140-N
WLSD-RP
WLSD-RP-N
WLSD2-55
WLSD2-55-N
WLSD2-55LD
WLSD2-139
WLSD2-140
WLSD2-RP60
WLSD2-TH
WLSD2-55LD-N
WLSD2-139-N
WLSD2-140-N
WLSD2-RP60-N
WLSD2-TH-N
WLCA2-141
WLCA2-141-N
WLCA2-141LD2
WLCA2-141LD3
WLCA2-RP60
WLCA2-RP60LD2
WLCA2-RP60LD3
WLCA2-TH
WLCA2-141LD2-N
WLCA2-141LD3-N
WLCA2-RP60-N
WLCA2-RP60LD2-N
WLCA2-RP60LD3-N
WLCA2-TH-N
WLSD2-TC
WLSD2-TC-N
WLSD2-RP
WLSD2-RP-N
WLNJ-55
WLNJ-55-N
WLCA2-TC
WLCA2-TC-N
WLNJ-55LD
WLNJ-139
WLNJ-55LD-N
WLNJ-139-N
WLCA2-RP
WLCA2-RP-N
WLCA2-P1
WLCA2-P1-N
WLCL-55LD
WLCL-139
WLCL-140
WLCL-RP60
WLCL-TH
WLCL-55LD-N
WLCL-139-N
WLNJ-140
WLNJ-140-N
WLH2-55
WLCA2-55-N
WLNJ-RP60
WLNJ-TH
WLNJ-RP60-N
WLNJ-TH-N
WLH2-55LD
WLCA2-55LD-N
WLCA2-55LE-N
WLCA2-139-N
WLCL-140-N
WLH2-55LE
WLCL-RP60-N
WLCL-TH-N
WLNJ-TC
WLNJ-TC-N
WLH2-139
WLNJ-RP
WLNJ-RP-N
WLH2-140
WLCA2-140-N
WLCL-TC
WLCL-TC-N
WLNJ-255
WLNJ-255-N
WLH2-141
WLCA2-141-N
WLCL-RP
WLCL-RP-N
WLNJ-255LD
WLNJ-2140
WLNJ-255LD-N
WLNJ-2140-N
WLNJ-2RP60-N
WLNJ-2RP-N
WLH2-141LD3
WLH2-RP60
WLCA2-141LD3-N
WLCA2-RP60-N
WLCA2-RP60LD3-N
WLCA2-TH-N
WLCL-P1
WLCL-P1-N
WLHL-TH
WLCL-2NTH-N
WLCL-2NTC-N
WLCL-2NRP-N
WLCL-2NP1-N
WLGL-TH-N
WLNJ-2RP60
WLNJ-2RP
WLH2-RP60LD3
WLH2-TH
WLHL-TC
WLHL-RP
WLCA2-LEAS
WLH2-LEAS
WLCA2-LDAS
WLH2-LDAS
WLCA2-LES
WLH2-LES
WLCA2-LEAS-N
WLCA2-LEAS-N
WLCA2-LDAS-N
WLCA2-LDAS-N
WLCA2-LES-N
WLCA2-LES-N
WLCA2-LDS-N
WLCA2-LDS-N
WLD28-LES-N
WLD28-LDS-N
WLMCA2-LD-N
WLMCA2-LDK13A-N
WLMCA2-LDK13-N
WLMCA2-LDK43A-N
WLMCA2-LDK43-N
WLMCA2-LD-M1J-N
WLMCA2-LD-DGJ-N
WLMCA2-LD-N
WLMCA2-LDK13A-N
WLMCA2-LDK13-N
WLMCA2-LDK43A-N
WLMCA2-LDK43-N
WLMCA2-LD-M1J-N
WLMCA2-LD-DGJ-N
WLRCA2-N
WLH2-TC
WLCA2-TC-N
WLHL-P1
WLH2-RP
WLCA2-RP-N
WLGL-TH
WLH2-P1
WLCA2-P1-N
WLCL-2TH
WLCL-2TC
WLCL-2RP
WLCL-2NTH
WLCL-2NTC
WLD2-55
WLCL-2TH-N
WLCL-2TC-N
WLCL-2RP-N
WLCL-2NTH-N
WLCL-2NTC-N
WLD28-55-N
WLCA2-255
WLCA2-255-N
WLCA2-255LD
WLCA2-255LE
WLCA2-2139
WLCA2-2139LD2
WLCA2-2139LD3
WLCA2-2RP60
WLCA2-2RP60LD2
WLCA2-2RP60LD3
WLCA2-2TH
WLCA2-2TC
WLCA2-2N55
WLCA2-2N55LD
WLCA2-2N55LE
WLCA2-2N139
WLCA2-2N140
WLCA2-2NTH
WLCA2-2NTC
WLCA12-55
WLCA2-255LD-N
WLCA2-255LE-N
WLCA2-2139-N
WLCA2-2139LD2-N
WLCA2-2139LD3-N
WLCA2-2RP60-N
WLCA2-2RP60LD2-N
WLCA2-2RP60LD3-N
WLCA2-2TH-N
WLCA2-2TC-N
WLCA2-2N55-N
WLCA2-2N55LD-N
WLCA2-2N55LE-N
WLCA2-2N139-N
WLCA2-2N140-N
WLCA2-2NTH-N
WLCA2-2NTC-N
WLCA12-55-N
WLCA2-LDS
WLH2-LDS
WLD28-LES
WLD28-LDS
WLMCA2-LD
WLMCA2-LDK13A
WLMCA2-LDK13
WLMCA2-LDK43A
WLMCA2-LDK43
WLMCA2-LD-M1J
WLMCA2-LD-DGJ03
WLMH2-LD
WLD2-55LD
WLD2-55LE
WLD2-139
WLD2-RP60
WLD2-TH
WLD28-55LD-N
WLD28-55LE-N
WLD28-139-N
WLD28-RP60-N
WLD28-TH-N
WLD28-TC-N
WLD28-RP-N
WLD28-55-N
WLD2-TC
WLD2-RP
WLD28-55
WLD28-55LD
WLD28-55LE
WLD28-139
WLD28-140
WLD28-RP60
WLD28-TH
WLD28-RP
WLSD-55
WLD28-55LD-N
WLD28-55LE-N
WLD28-139-N
WLD28-140-N
WLD28-RP60-N
WLD28-TH-N
WLD28-RP-N
WLSD-55-N
WLMH2-LDK13A
WLMH2-LDK13
WLMH2-LDK43A
WLMH2-LDK43
WLMH2-LD-M1J
WLMH2-LD-DGJ03
WLRCA2
WLCA12-55LD
WLCA12-55LE
WLCA12-139
WLCA12-140
WLCA12-141
WLCA12-55LD-N
WLCA12-55LE-N
WLCA12-139-N
WLCA12-140-N
WLCA12-141-N
WLSD-55LD
WLSD-139
WLSD-RP60
WLSD-55LD-N
WLSD-139-N
WLSD-RP60-N
WLRH2
WLRCA2-N
WLRCA2-2
WLRCA2-2-N
WLRCA2-2N
WLRCA2-2N-N
59
WL-N/WL
WL
WLRCA2
WL-N
WLRCA2-N
WLRH2
WLRCA2-N
WLRCA2-2
WLRCA2-2N
WLRCL
WLRCA2-2-N
WLRCA2-2N-N
WLRCA2-N
WLRCA2-2
WLRCA2-2N
WLRCA32
WLRCA2-LDS
WLRH2-LES
WLRH2-LDS
WLRCA2-2-N
WLRCA2-2N-N
WLRCA32-N
WLRCA2-LDS-N
WLRCA2-LES-N
WLRCA2-LDS-N
60
WL-N/WL
Model Replacement Table (Replacing WL-N High-sensitivity and High-
precision Models with WL High-sensitivity and High-precision Models)
The WL-N high-sensitivity and high-precision models have been integrated into the WL Series. To use a WL-N high-sensitivity or high-precision
model, find the corresponding WL high-sensitivity or high-precision model in the following model replacement table, and order the switch with the
WL model number.
WL-N
WL
WL-N
WL
WL-N
WL
WL01G2-TH-F
WLG2-TH-F
WLGCA2-LDS-N
WLGCA2-LDS-M1J-1-N
WLGCA2-LDS-M1GJ-1-N
WLGCA2-LDS
WLG2-55LD-M1JB-N WLG2-55LD-M1JB
WLG2-55LD-M1GJ-N WLG2-55LD-M1GJ 0.3M
WLGCA2-LDS-M1J-1
WLGCA2-LDS-M1GJ-1
WL01GCA2-LD
WLG2-TH-N
WL01G2-55LDK43
WLG2-55LDK43-N
WLG2-TH
WLG2-55LDK43
WL01G2
WLGCA2-LD-N
WLG2-N
WLGCA2-LD
WL01G2-55LDK13
WLG2
WLGCA2-LD-M1J-N
WLGCA2-LD-M1GJ-N
WLGCA2-LD-M1J
WLGCA2-LD-M1GJ 0.3M
WL01GCA2-LDK43
WLGCA2-LDK43
WLGCA2-LDK13
WLGCA2-LD-DGJ03
WLGCA2-55
WLG2-55LDK13-N
WLG2-55LDK13
WL01G2-LDS
WLG2-LDS
WLG2-LDS-N
WLG2-LD-N
WLG2-LD-M1J-N
WLG2-55LDK13CE
WLG2-55LD-DTK1EJ03
WLG2-55LD-DTK1EJ-N
WL01G2-LD
WLGCA2-LDK43-N
WLG2-55LD-DK1EJ-N WLG2-55LD-DK1EJ03
WLG2-LD
WLGCA2-LDK13-N
WLGCA2-LD-DGJ-N
WLGCA2-55-N
WL01G2-55LD-DGJ03
WLG2-55LD-DGJ-N
WL01G2-LD-M1J
WLG2-LD-M1J
WLG2-LD-M1JB 0.3M
WLG2-LD-M1GJ 0.3M
WL01G2-LD-DGJ03
WLG2-LD-DGJ03
WL01G12-TH
WLG12-TH
WLG2-55LD-DGJ03
WLG2-141-N 5M
WLG2-141-N 2M
WLG2-141 5M
WLG2-141 2M
WL01G2-141LD3 5M
WLG2-141LD3 5M
WLG2-141LD2 5M
WLG2-140 5M
WLG2-139 5M
WLG2-139 3M
WLG2-139LD3 5M
WLG12-TC
WLG2-LD-M1JB-N
WLG2-LD-M1GJ-N
WLGCA2-55LE-N
WLGCA2-55LE
WL01GCA2-55LD
WLGCA2-55LD
WLGCA2-55LD-N
WLG2-141LD3-N 5M
WLG2-LD-DGJ-N
WLG12-TH-N
WLG12-N
WLGCA2-55LD-M1J-N
WLGCA2-55LD-M1JB-N
WLGCA2-55LD-M1GJ-N
WLGCA2-55LD-M1J 0.3M
WLGCA2-55LD-M1JB 0.3M
WLGCA2-55LD-M1GJ 0.3M
WL01GCA2-55LDK43
WLGCA2-55LDK43
WL01GCA2-55LDK13
WLGCA2-55LDK13
WLGCA2-55LDK13CE
WLGCA2-55LD-DGJ03
WLGCA2-139 5M
WLGCA2-139 3M
WLGCA2-139 2M
WLG2-141LD2-N 5M
WLG2-140-N 5M
WLG2-139-N 5M
WLG2-139-N 3M
WLG2-139LD3-N 5M
WLG12-TC-N
WL01G12
WLG12
WLGCA2-55LDK43-N
WLR01G2
WLRG2-N
WLRG2
WLGCA2-55LDK13-N
WLG12-P1-N
WLG12-P1
WLRG2-LDS-N
WLRG2-LDS
WLMGCA2-LD
WLMGCA2-LD-M1J
WLMGCA2-LDK43
WLMGCA2-LDK13
WLMGCA2-LDK13A
WLMG2-LD
WLG12-LE-N
WLG12-LE
WLMGCA2-LD-N
WLMGCA2-LD-M1J-N
WLMGCA2-LDK43-N
WLMGCA2-LDK13-N
WLMGCA2-LDK13A-N
WLMG2-LD-N
WLGCA2-55LD-DGJ-N
WLGCA2-139-N 5M
WLGCA2-139-N 3M
WLGCA2-139-N 2M
WLG12-LD-N
WLG12-LD
WL-2H4100-N
(FOR WLGL-N)
None
None
None
None
None
WL-2H2100-N
(FOR WLG12-N)
WLGCA2-
139LD3-N 5M
WLGCA2-
1395LD3 S-FLEX 5M
WL-2H1100W-N
(FOR WLG2-141-N)
WLMG2-LD-M1J-N
WLMG2-LDK43-N
WLMG2-LDK13-N
WLMG2-LDK13A-N
WLMG2-LD-DGJ-N
WLGL-TH-N
WLMG2-LD-M1J
WLMG2-LDK43
WLMG2-LDK13
WLMG2-LDK13A
WLMG2-LD-DGJ03
WLGL-TH
WLGCA2-139LD3-N 5M WLGCA2-139LD3 5M
WLGCA2-139LD2-N 5M WLGCA2-139LD2 5M
WL-2H1100S-N
(FOR WLG2-S-N)
WLG2-TC-N
WLG2-TC
WL-2H1100-N
(FOR WLG2-N)
WLG2-RP-N
WLG2-RP
WLG2-RP60-N 5M
WLG2-RP60-N 10M
WLG2-RP60
WLG2-RP60 10M
WLGL-TC-N
WLGL-TC
WLG2-RP60LD3-N 5M WLG2-RP60LD3
WLG2-RP60LD2-N 5M WLG2-RP60LD2
WLGL-P1-N
WLGL-P1
WL01GL
WLGL-N
WLG2-P1-N
WLG2-P1
WLGL
WLG2-LES-N
WLG2-LES
WLGL-LE-N
WLGL-LD-N
WLGL-LE
WL01G2-LE
WLG2-LE
WLGL-LD
WLG2-LE-N
WL01GCA2-TH
WLGCA2-2TH
WLGCA2-TH
WLGCA2-TC
WLGCA2-RP
WLGCA2-RP60
WLGCA2-RP60LD3
WLGCA2-RP60LD2
WL01GCA2
WLG2-LEAS-N
WLG2-LDK43-N
WLG2-LEAS
WLG2-LDK43
WL01G2-LDK13
WLG2-LDK13
WLG2-LD-DK1EJ03
WLG2-LDAS
WL01G2-55
WLGCA2-TH-N
WLGCA2-TC-N
WLG2-LDK13-N
WLGCA2-RP-N
WLG2-LD-DK1EJ-N
WLG2-LDAS-N
WLGCA2-RP60-N 5M
WLGCA2-RP60LD3-N 5M
WLGCA2-RP60LD2-N 5M
WLG2-55-N
WLG2-55
WLGCA2-N
WLG2-55LE-N
WLG2-55LD-N
WLG2-55LD-M1TJ-N
WLG2-55LE
WL01G2-55LD
WLG2-55LD
WLG2-55LD-M1TJ
WLGCA2
WLGCA2-LES-N
WLGCA2-LE-N
WLGCA2-LES
WL01GCA2-LE
WLGCA2-LE
WLG2-55LD-M1TJB-N WLG2-55LD-M1TJB
61
WL-N/WL
Safety Precautions
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near
the Switch, suppress arcing with contact protective circuits (surge
suppressor) or remove the source of silicon gas.
Precautions for Safe Use
• Be sure to ground. Otherwise electric shock may result.
• Do not touch charged switch terminals while the switch has carry
current, Otherwise electric shock may result.
• Do not disassemble the limit switch or touch inside of it under
supplying power,
Otherwise electric shock may result.
• Do not disassemble the limit switch or touch inside of it under
supplying power, otherwise there is the possibility that electrical
shock occurs.
• Do not touch the wire or rod type actuator in order to prevent injury.
• Connect a fuse which has 1.5 to 2 times higher breaking current
than the switch rated current to the switch in series in order to
prevent the switch from short-circuit damage.
Installing the Switch
• To install the Switch, make a mounting panel, as shown in the
following diagram, and tighten screws using the appropriate
tightening torque.
• On the occasion when using the switch with GB ratings, use a 10A
fuse that complies IEC60269, either type gG.
• The durability of switch is depends on the operating condition Be
sure to check the condition with actual using condition before
using, and use with the number of times of operating without a
performance problem.
Front Mounting : Four, 5.2+0.2 dia. holes
0
or M5 tapped holes
0.15
58.7
Rear Mounting : Four, 6.2 +0.2 dia. holes
0
• Otherwise, there is the possibility of spoiling the normal operation.
Do not drop the switch.
• Do not connect a Single Limit Switch to two power supplies that are
different in polarity or type. Risk of interference.
• Be sure to keep the load current less than the rated value.
Otherwise, there is the possibility that the switch may be damage
and/or burnout.
• Do not use the Switch by itself in atmospheres containing
flammable or explosive gases. Arcs and heating resulting from
switching may cause fire or explosion.
• Be sure to prevent the foreign materials such like a scrapped cable
intrusion in to the switch when wiring. Otherwise, there is the
possibility of spoiling the normal operation.
• Never wire to the wrong terminals.
• Do not store or use the switch with following place.
Where the temperature fluctuates greatly
0.15
30.2
Using Switches for Micro Loads
Contact faults may occur if a Switch for a general-load is used to
switch a micro load circuit. Use switches in the ranges shown in the
diagram below. However, even when using microload models within
the operating range shown here, if inrush current occurs when the
contact is opened or closed, it may increase contact wear and so
decrease durability. Therefore, insert a contact protection circuit
where necessary.
For the WL-N, the P level is at the min. operating load of 5 VDC and
1 mA resistive load.
Note: The P level indicates the standard malfunction level at a
reliability level of 60% (λ60).
Where the humidity is very high and condensation may occur.
Where the vibration is too much
Where receiving direct sunshine.
(JISC5003) λ60 =0.1×10-6/operations indicates that the
estimated malfunction rate is less than 1/10,000,000
operations with a reliability level of 60%.
Where receiving salty wind.
For the WL01G@, the N level is a reference value at the min.
operating load of 5 VDC and 1 mA resistive load. An estimated
malfunction rate of 1/2,000,000 operations at a reliability level of 60%
is indicated as a reference value.
• Do not disassemble and/or modify the switch at anytime.
Otherwise, there is the possibility of spoiling the normal operation.
• Do not apply the force such like deformation and/or degeneration
to the switch.
5 mW
800 mW
0.16 mA
26 mA
30
24
Precautions for Correct Use
Environment
Operating range
for standard
models
• Take special care to use where there is fine powder, mud and/or
foreign materials stacking. And check the condition with actual
using condition before using. Then use without a performance
problem.
Operating range
for micro-load
models
• Do not keep the Switch in locations with corrosive gas, such as
sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),
or chlorine gas (Cl2), or high temperature and humidity.Otherwise,
contact failure or corrosion damage may result.
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
12
Unusable
range
5
0
1 mA
1
100 mA 160 mA
0.1
10
100
1,000
Current (mA)
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
Suitable
62
WL-N/WL
In the case of prewired connector and direct
Tightening Torque
connector
• If screws are too loose they can lead to
an early malfunction of the Switch, so
ensure that all screws are tightened
using the appropriate tightening torque.
• In particular, when changing the
direction of the Head, make sure that all
screws are tightened again to the
appropriate tightening torque. Do not
allow foreign objects to fall into the
Switch.
• Holding the connector certainly when pulling connector.
• Don’t pull the cable holding it.
(1)
(6)
(3)
How to handle
Changing direction of the head
• By removing two head screws or four head screws, mounting in
any of four orientations is possible. Be sure to change the plunger
for internal operations at the same time.
(4)
(2)
Built-in Switch
• Do not remove or replace the built-in switch. Risk of
malfunctioning.
(5)
No.
Type
Torque
Screw type
M3.5 screw
M4 screw
Overtravel Markers
• All Switches with Roller Lever Actuators except for Switches with
Fork Lock Levers and Low-temperature Switches have a set
position marker plate.
0.78 to 0.88
(1) Head mounting screw
(2) Cover mounting screw
N•m
1.18 to 1.37
N•m
• To allow the roller lever type actuator to travel properly, set the
roller lever according to the dog or cam stroke so that the
arrowhead of the lever is positioned within the overtravel markers
(pages 36, 37).
Allen-head bolt
(3)
4.90 to 5.88 M5 hexagon socket
N•m head cap screw
(for securing the roller lever)
Allen-head bolt
(3) (for securing the adjustable
rod lever)
0.88 to 1.08 M8 hexagon socket set
N•m
screw
Connectors
0.59 to 0.78
(4) Terminal screw
(5) Connector
M3.5 screw
N•m
• Tighten the connector with the appropriate torque to prevent
deformation.
1.77 to 2.16 G1/2orPg13.5orM20or
N•m
1/2-14NPT
• Use the OMRON type SC connector series, which is prepared
separately, suitable for outer diameter of cable and inner diameter
of seal rubber.
• Make sure to wrap the connector with the seal tape, except the
connector which has O-ring, to keep the sealability.
• To conform to CSA, use a CSA certified water tight treated conduit
hub.
• Even when the connector is assembled and set correctly, the end
of the cable and the inside of the Switch may come in contact. This
can lead to malfunction, leakage current, or fire, so be sure to
protect the end of the cable from splashes of oil or water and
corrosive gases.
4.90 to 5.88
Unit mounting screw
(6)
M5 screw
N•m
4.90 to 5.88
Back mounting screws
M6 screw
N•m
Wring
In the case of mounting screw
Basic Switches
• Use M3.5-nylon insulation covered crimp terminals (round type) for wiring.
Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.)
• Appropriate wire size is AWG16 (1.25 mm2).
• Do not supply electric power when wiring. Otherwise electric shock
may result.
Microload Applications
• The WL-N Basic Models contacts can be used both for standard
loads and microloads, but once a contact has been used to open
and close a load it can no longer be used for lower loads. Doing so
will damage the contact surface and reduce contact reliability.
• If an inrush current or other sudden load occurs during a switch
operation, the switch will begin to degrade severely which can
result in reduced durability. Use a contact protection circuit if
required.
• Do not pull out the wires with excessive force. It may cause of
coming off the wire.
• Use crimp terminals for wiring.
• In the case of indicator unit, to avoid interference
between lump unit and crimp terminals, wire
according to right wiring figure.
Attach the indicator unit spring to terminal screw
certainly, otherwise it's possible to be destroyed or
shorted.
Indicator
• The ground terminal is only installed on models
with ground terminals.
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the indicator
circuit and may cause load's malfunction. Leakage current may cause
load malfunction (i.e., the load may remain ON). Make sure that the
load operating current is higher than the leakage current. For
countermeasures, refer to technical support on your OMRON
website.
High-sensitivity and High-precision Switches
• Use 1.25-mm2 lead wires and M4-insulation covered crimp
terminals for wiring.
Crimp Terminal External
Wiring Method
Switch Box Section
Ground terminal
Dimensions
L
F
l
D dia.
B
dz dia.: 4.3
D dia. : 4.5
dz dia.
B
L
F
l
: 8.5
: 21.0
: 7.8
NO terminal
NC terminal
: 9.0 (mm)
• The ground terminal is only installed on models with ground terminals.
63
WL-N/WL
Terminal Plate
Basic Switches
By using the Terminal Plate (sold separately), as shown in the
following diagram, the Switch can be used as a single-polarity double-
break switch.
Attach the Terminal Plate
so that the “COM” mark is
oriented as shown on the left.
Terminal Plate
Terminal Plate Mounting Diagram
(with Two Terminal Screws Removed)
Model
WL-N TERMINAL PLATE
High-sensitivity/High-precision Switches
By using a short circuit plate, as shown in the following diagram, the
Switch can be fabricated into a single-polarity double-break switch.
When ordering, specify WL Terminal Plate (product code: WL-
9662F).
9
2.5+0.2
7.1
0
3R
COM
9
0.2
23 0.4
16 0.15
7
2R
3.5
2.1R
4.2+0.1
t = 0.6 Brass plate
0
Using a WL@-2N Switch Mounted from the Side
If you replace a previous Switch with a WL@-2N-N Switch, a Mounting
Plate (sold separately) is available to maintain mounting compatibility.
If you use the Mounting Plate, the Switch mounting holes and actuator
position will be compatible. (The position of the dog remains
unchanged.)
Mounting Plate
23
30.2
WL@-2N
Mounting Plate
Replacing a Switch
with the WL@-2N-N
Plate mounting
bolts (2)
Set
contents
Switch mounting
bolts (2)
Plate (1)
WLN-P001
Model
64
WL-N/WL
• Make sure that the actuator does not exceed the OT (overtravel)
range, otherwise the Limit Switch may malfunction. When
mounting the Limit Switch, be sure to adjust the Limit Switch
carefully while considering the whole movement of the actuator.
Operation
• Carefully determine the position and shape of the dog or cam so
that the actuator will not abruptly snap back, thus causing shock.
In order to operate the Limit Switch at a comparatively high speed,
use a dog or cam that keeps the Limit Switch turned ON for a
sufficient time so that the relay or valve will be sufficiently
energized.
Operating
body
PT (Pretravel)
Install a stopper.
70% of
• The method of operation, the shape of the cam or dog, the
operating frequency, and the travel after operation have a large
influence on the durability and operating accuracy of the Limit
Switch. The cam or dog must be smooth in shape.
FP (Free position)
OP (Operating position)
100% of
rated OT
OT (Overtravel)
rated OT
TTP (Total travel position)
Incorrect
Correct
Optimum setting range
Distance to the
optimum setting range.
Snapped
back
Reference line
Abruptly
actuated
• The Limit Switch may soon malfunction if the OT is excessive.
Therefore, adjustments and careful consideration of the position of
the Limit Switch and the expected OT of the operating body are
necessary when mounting the Limit Switch.
Incorrect
Correct
Snapped
back
Correct
Abruptly
actuated
Stopper
• Appropriate force must be imposed on the actuator by the cam or
dog in both rotary operation and linear operation.
If the dog touches the lever as shown below, the operating position
will not be stable.
• When using a pin-plunger actuator, make sure that the stroke of
the actuator and the movement of the dog are located along a
single straight line.
Incorrect
Correct
Incorrect
Correct
Dog
Dog
Operating
body
Operating
body
• Unbalanced force must not be imposed on the actuator. Otherwise,
wear and tear on the actuator may result.
Incorrect
Correct
Others
Dog
Roller
Dog
Roller
• For long term (over a year) storage, check according to Operating
characteristics, Contact resistance and Dielectric strength at least.
And check with using condition.
• The durability of the Switch is greatly affected by operating
conditions.
Evaluate the Switch under actual working conditions before
permanent installation and use the Switch within a number of
switching operations that will not adversely affect the Switch’s
performance.
• With a roller actuator, the dog must touch the actuator at a right
angle. The actuator or shaft may deform or break if the dog touches
the actuator (roller) at an oblique angle.
Incorrect
Correct
Dog
65
WL-N/WL
Using the Switches
Item
Applicable models and Actuators
Details
Roller lever:
Changing the Installation Position of the
Actuator
By loosening the Allen-head bolt on the ac-
tuator lever, the position of the actuator can
be set anywhere within the 360°.
With Operation Indicator-equipped Switch-
es, the actuator lever comes in contact with
the top of the indicator cover, so use caution
when rotating and setting the lever. When
the lever only moves forwards and back-
wards, it will not contact the lamp cover.
(This does not apply to Long-life Models.)
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2,
WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N,
WLMG2, WLMGCA2)
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable Rod Lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL,
Loosen the Allen-head bolt, set
the actuator's position and then
tighten the bolt again.
WLCAL4-N, WLCAL5-N)
Roller lever:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2,
WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N,
WLMG2, WLMGCA2)
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable Rod Lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL,
WLCAL4-N, WLCAL5-N)
Horizontal plunger:
Loosen the screws.
Head
Changing the Orientation of the Head
By removing the head screws (two or four
screws), mounting in any of four orientations
is possible. Be sure to change the plunger
for internal operations at the same time.
The roller plunger can be set in either of two
positions at 90°.
(WLSD@-N)
Top-roller plunger:
(WLD2-N)
Sealed top-roller plunger:
(WLD28-N)
Fork lock lever:
(WLCA32-4@-N)
Note: Excludes the -RP60-series and -
141-series.
One-side Operation
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Roller lever:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLCA2-7-N,
WLCA2-8-N, WLMCA2-N)
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N)
Operating Operating Not operating Operating
Operating
Not operating
Adjustable Rod Lever:
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLCAL4-N,
WLCAL5-N)
Changing the Operating Direction
By removing the Head on models which can
operate on one-side only, and then changing
the direction of the operational plunger, one
of three operating directions can be selected.
The tightening torque for the screws on the
Head is 0.78 to 0.88 N·m.
Operation in both
directions
Clockwise operation
Counterclockwise
operation
One-side Operation for High-sensitivity and High-precision Switches
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Operating Operating Not operating Operating Operating Not operating
Roller lever:
(WLGCA2, WLMGCA2)
Operational
plunger
Operation in both
directions
Clockwise operation
Counterclockwise
operation
66
WL-N/WL
Item
Applicable models and Actuators
Details
Roller lever:
(WLCA2-N, WLCA2-2-N,
WLCA2-2N-N, WLG2,
WLCA2-7-N, WLCA2-8-N,
WLGCA2, WLMCA2-N,
WLMG2, WLMGCA2)
Fork Lock Lever:
Installing the Roller on the Inside
By installing the roller lever in the opposite
direction, the roller can be installed on the in-
side. (Set so that operation can be complet-
ed within a 180° level range.)
Loosen the
Allen-head bolt.
(WLCA32-4@-N)
Loosen this
Adjustment
Allen-head bolt
and adjust the
length of the rod.
range radius:
25 to 140 mm
Loosen this
Adjustment
range radius:
25 to 89 mm
Allen-head bolt
and adjust the
length of the
lever.
Adjustable Roller Lever:
(WLCA12-N, WLCA12-2-N,
WLCA12-2N-N, WLG12)
Adjustable Rod Lever:
Adjusting the Length of the Rod or Lever
The length of the rod or lever can be adjust-
ed by loosening the Allen-head bolt.
(WLCL-N, WLCL-2-N,
WLCL-2N-N, WLGL, WLCAL4-N)
Adjustable Roller Levers:
WLCA32-41-N
Adjustable Rod Levers:
WLCA32-43-N
Selecting the Roller Position
There are four types of Switches with Fork
Lock Levers for use depending on the roller
position.
Fork Lock Lever:
(WLCA32-4@-N)
WLCA32-42-N
WLCA32-44-N
An explanation of the operation of fork lock levers is provided after this
table.
Operation of Fork Lock Levers
A Switch with a Fork Lock Lever is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after
the dog moves on.
If the dog then pushes the lever from the opposite direction, the lever will return to its original position.
Example
NC terminal: ON
NO terminal: ON
NO terminal: ON
67
WL-N/WL
Limit Switch Connectors
Connectors (SC Series)
Cabtire cables and flexible tubes with various diameters are used to
connect machine tools and controllers with Limit Switches. To ensure
the watertightness of the edges of the conduits, use an SC Connector
that is suitable for the external diameter of cable and model of Limit
Switch.
Ordering Information
Connector for Cabtire Cable
External diameter of cable
Min. Max.
5.5 mm 7.5 mm
Innerdiameter(D)
of seal rubber
Conduit
Applicable cable
Model
SC-1M
Applicable model
7 mm
9 mm
7.5 mm
11 mm
12 mm
9 mm
9.5 mm
13 mm
14 mm
11 mm
7.5 mm
9.5 mm
13 mm
14 mm
11 mm
7.5 mm
9.5 mm
13 mm
14 mm
11 mm
SC-2M
SC-3M
SC-4M
SC-5M
SC-21
Cabtire cable (general-
purpose)
12.5 mm
14 mm
11 mm
7 mm
WL-N, WL, D4A-@N, D4B-@N,
ZE, ZV, ZV2, XE, XV, XV2
JIS B 0202 G½
5.5 mm
7.5 mm
11 mm
12 mm
9 mm
9 mm
SC-22
Cabtire cable (anti-cor-
rosive)
12.5 mm
14 mm
11 mm
7 mm
SC-23
SC-24
SC-25
5.5 mm
7.5 mm
11 mm
12 mm
9 mm
SC-1PT
SC-2PT
SC-3PT
SC-4PT
SC-5PT
9 mm
½-14NPT
Cabtire cable
12.5 mm
14 mm
11 mm
D4A-@N
Note: Please use sealing tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is
not necessary to ensure a proper seal.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
External diameter of cable
Innerdiameter(D)
of seal rubber
Conduit
Applicable cable
Model
SC-P2
Applicable model
Min.
Max.
10.5 mm
9.5 mm
WL-N, WL, D4A-@N, D4B-@N,
ZE, ZV, ZV2, XE, XV, XV2
JIS B 0202 G½
Pg13.5
10.6 mm
9.6 mm
8.5 mm
7.5 mm
7.5 mm
SC-P3
SC-6
WL@-G-N
Cabtire cable
WL-N, WL, D4A-@N, D4N *,
D4N-@R *, D4B-@N, ZE, ZV,
ZV2, XE, XV, XV2
JIS B 0202 G½
9 mm
9 mm
Note: Simple connector are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
Models marked with an asterisk (*) however, can only be used with resin connectors.
68
WL-N/WL
Dimensions and Structure
(Unit: mm)
Connectors for Cabtire Cable
As for models without an O-ring, please use sealing tape with SC Connectors.
Ball head lock nut
(brass and nickel plating)
Metal Models without O-ring
G½
SC-21 to 25
JIS B 0202 G
½
Sealing rubber
(nitrile rubber)
14.6 dia.
*E
24
14 dia.
4.8
15
9
Washer (stainless steel)
Connector
(brass and nickel plating)
27.7
29.3
*D
(34)
Ball head lock nut
(zinc die-cast and zinc plating)
Metal Models with O-ring
G½
Sealing rubber
(nitrile rubber)
JIS B 0202 G
½
14.6 dia.
*E
27
14 dia.
Washer (stainless steel)
15
5 9
Connector
(zinc die-cast and
zinc plating)
SC-1M to 5M
*D
29.3
30
Sealing rubber (nitrile rubber)
(34)
Ball head lock nut
(zinc die-cast and zinc plating)
Metal Models without O-ring
½-14NPT
(U.S.-standard screws)
SC-1PT to 5PT
14.6 dia.
14 dia.
24
14 dia.
5
½-14NPT
27.7
Sealing rubber (nitrile rubber)
15
14
Washer (stainless steel)
Connector
(zinc die-cast and
zinc plating)
*D
29.3
(39)
Note: Dimensions not shown in the above diagrams have a variation of 0.4 mm.
Simple Connectors (Not Suitable for Locations Subject to Oil or Water)
Conduit washer
(ferrous metal and
zinc plating)
Resin Models
G½
SC-P2
JIS B 0202
15
Hexagonal nut
(polyacetal resin)
1
4.5
G
½
22
5
Ring (chloroprene rubber)
18 dia.
12.6 dia.
18 dia.
10.6 dia.
25.4
Conduit washer
(ferrous metal and
zinc plating)
Resin Models
Pg13.5
SC-P3
Hexagonal nut
(polyacetal resin)
15.5 Pg13.5
5
1
4.5
21
Ring (chloroprene rubber)
18 dia.
18 dia.
23.5
12 dia.
9.6 dia.
Ball head lock nut
(polyacetal resin)
Resin Models
G½
SC-6
(30.6)
22.5
12
9
Sealing rubber (nitrile rubber)
10
9
12
Washer
Connector
(polyacetal resin)
5
9
(ferrous metal and
zinc plating)
*D
26
G
½
M20 × 1.5
Note: Dimensions not shown in the above diagrams have a variation of 0.4 mm.
* Diameter of Part Marked with Asterisk
Inner diameter (D)
of sealed rubber
Internal diameter
(E) of washer
Model
Applicable cable
SC-21, -1M, -1PT 7 mm
SC-22, -2M, -2PT 9 mm
SC-23, -3M, -3PT 12.5 mm
10.4 mm
13.2 mm
14.6 mm
14.6 mm
13.2 mm
10 mm
5.5 to 7.5-mm dia.
7.5 to 9.5-mm dia.
11 to 13-mm dia.
12 to 14-mm dia.
9 to 11-mm dia.
7.5 to 9-mm dia.
SC-24, -4M, 4PT
SC-25, -5M, -5PT 11 mm
SC-6 9 mm
14 mm
69
MEMO
70
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation
Kyoto, JAPAN
Industrial Automation Company
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
© OMRON Corporation 2017 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
CSM_1_2_0417
Cat. No. C151-E1-01