WLCL-LD-N [OMRON]

Snap Acting/Limit Switch;
WLCL-LD-N
型号: WLCL-LD-N
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch

文件: 总28页 (文件大小:3616K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Two-circuit Limit Switch  
WL-N  
Select the Best Two-circuit Switch for  
the Operating Environment and  
Application.  
• Standard-feature crossbar contacts provide high  
contact reliability.  
Applicable to either standard loads or microloads.  
• Standard features include 90° overtravel, one-  
side operation, and four-direction mounting.  
• IP67 degree of protection.  
• Approved standards: EN/IEC, UL, cUL, and CCC.  
Contact your OMRON representative for  
information on approved models.  
Be sure to read Safety Precautions on page 24 to 26 and  
Safety Precautions for All Limit Switches.  
Features  
Easy to Select  
The contacts can be used with either standard loads or microloads.  
Standard features include 90° overtravel, one-side operation, and  
four-direction mounting.  
Easy to See (Models with Operation Indicators)  
An indicator with a wide field of view has been used.  
Easy to Work With  
Downsizing of the built-in switch has increased the space to house  
the wiring.  
Steel screws that are attracted by magnetic screwdrivers have  
been used for the terminal screws inside the Switches.  
Resin and elastomer resistance has replaced the insulating paper.  
Internal Structure  
WL  
WL-N *1  
A 3D structure  
disperses light !  
Whether the indicator is lit can be clearly seen from the side.  
More space!  
*1. The wiring method is different for models with indicators.  
Refer to Wring on page 25 under Safety Precautions.  
Easy tightening  
with magnetized  
screwdrivers!  
1
WL-N  
Product Configuration  
Lineup of rotational lever models  
Additional series planned in the future: plunger models, fork lever lock models, and flexible rod models  
Basic Switches  
WLC@-N  
WLG@-N  
High-sensitivity Switches  
Standard  
High-precision Switches  
Protective  
Use the WL Series. *1  
Use the WL Series. *1  
General-purpose  
Indicator-equipped Switches:  
Neon lamps  
Operation indicators  
Indicator-equipped Switches:  
Light emitting diodes (LED)  
WL@-LD-N  
Direct-wired Switches  
Pre-wired Switches  
WL@-@LDK@-N  
Sensor I/O connectors  
WL@-@LD-M1@-N  
WL@-@LD-AGJ@-N  
WL@-@LD-DGJ@-N  
Heat-resistant Switches  
Low-temperature Switches  
Weather-proof Switches  
Airtight Switches  
WL@-TH-N  
WL@-TC-N  
WL@-P1-N  
Environment-resistant  
Use the WL Series. *1  
Hermetic Switches  
Corrosion-proof Switches  
Basic Switches  
WLC@-@S-N  
Spatter-prevention  
High-sensitivity Switches  
High-precision Switches  
WLG@-@S-N  
Use the WL Series. *1  
Use the WL Series. *1  
Long-life  
*1. Planned to be added to the WL-N Series in the future.  
2
WL-N  
Model Number Structure  
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)  
General-purpose Switches  
WL@ - @ @ @ @ @ -N  
(1) (2) (3) (4) (5) (6)  
(1) Actuator and Property Specifications  
(3) Conduit Size, Ground Terminal Specifications  
Symbol  
RCA2  
CA2  
Lever  
Pretravel (PT)  
Specifications  
Symbol  
Without Lever  
Ground terminal presence  
or absence  
Conduit Size  
Roller lever: R38 mm  
Blank  
G1  
G1/2  
Without ground terminal  
CA2-7  
CA2-8  
CA12  
CL  
Roller lever: R50 mm  
15±5°  
G1/2  
Roller lever: R63mm  
With ground terminal *1  
G
Pg13.5  
Adjustable roller lever: R25 to 89 mm  
Adjustable rod lever: 25 to 140 mm  
Without Lever  
*1. Cannot be combined with Connector Type models.  
RG2  
G2  
(4) Indicator Type  
Roller lever: R38 mm  
+2°  
10°  
1°  
Symbol  
Blank  
LD  
Specifications  
G12  
Adjustable roller lever: R25 to 89 mm  
Adjustable rod lever: 25 to 140 mm  
No indicator  
GL  
LED 10 to 115VAC/DC  
(2) Built-in Switch Type  
(5) Lever Type  
Symbol  
Specifications  
Symbol  
Specifications  
Blank  
Standard  
Blank  
A
Standard lever (Allen-head bolt)  
Double nut lever  
(6) Connector Type  
Specifications  
Symbol  
Shape  
Voltage  
----  
Wiring locations  
----  
Connector pin No. *2  
Blank  
K13A  
K13  
No Connector  
----  
----  
3
4
4
AC  
DC  
AC  
DC  
DC  
DC  
DC  
AC  
DC  
DC  
DC  
Only NO  
Only NO  
NC+NO  
NC+NO  
Only NO  
Only NO  
Only NC  
NC+NO  
Only NO  
Only NC  
NC+NO  
3
NC:  
NC:  
3
Direct-wired Connector  
Screw (M12)  
1
1
2
2
3
3
4
4
K43A  
K43  
, NO:  
, NO:  
4
4
2
-M1J  
1
-M1GJ  
-M1JB  
-AGJ  
Screw (M12)  
Smart Click  
3
1
1
2
2
3
3
4
4
Pre-wired Connector *3  
NC:  
3
, NO:  
, NO:  
4
2
-M1TJ  
-M1TJB  
-DTGJ  
3
NC:  
*2. Refer to Contact Forms on page 7 for details about connector pin numbers.  
*3. The standard cable length is 0.3 m. Contact your OMRON representative for information about other cable lengths.  
3
WL-N  
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)  
Environment-resistant Switches  
WL@ - @ @ @ @ @ -N  
(1) (2) (3) (4) (5) (6)  
(1) Actuator and Property Specifications  
Symbol  
RCA2  
CA2  
Lever  
Pretravel (PT)  
Without Lever  
Roller lever: R38 mm  
CA2-7  
CA2-8  
CA12  
CL  
Roller lever: R50 mm  
15±5°  
Roller lever: R63mm  
Adjustable roller lever: R25 to 89 mm  
Adjustable roller lever: 25 to 140 mm  
Without Lever  
RG2  
G2  
Roller lever: R38 mm  
+2°  
1°  
10°  
G12  
Adjustable roller lever: R25 to 89 mm  
Adjustable rod lever: 25 to 140 mm  
GL  
(2) Environment-resistant Model Specifications  
Symbol  
Blank  
P1  
Specifications  
Standard  
Weather-proof  
(3) Built-in Switch Type  
Symbol  
Specifications  
Specifications  
Blank  
Standard  
(4) Temperature Type  
Symbol  
Blank  
TH  
Standard: 10°C to +80°C  
Heat-resistant: +5°C to +120°C *1  
Low-temperature: 40°C to +40°C *1  
TC  
*1. Cannot be combined with Weather-proof Switches.  
(5) Conduit Size, Ground Terminal Specifications  
Specifications  
Symbol  
Conduit Size  
Ground terminal presence or absence  
Blank  
G1  
G1/2  
G1/2  
Without ground terminal  
With ground terminal  
G
Pg13.5  
(6) Lever Type  
Symbol  
Specifications  
Blank  
A
Standard lever (Allen-head bolt material: steel )  
Double nut lever (bolt material: stainless)  
4
WL-N  
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)  
Spatter-prevention Switches  
WL@ - @ @ @ @ S@ -N  
(1) (2) (3) (4) (5) (6)  
(1) Actuator and Property Specifications  
Symbol  
RCA2  
CA2  
Lever  
Pretravel (PT)  
15±5°  
Without Lever  
Roller lever: R38 mm  
Without Lever  
RG2  
+2°  
1°  
10°  
G2  
Roller lever: R38 mm  
(2) Built-in Switch Type  
Symbol  
Specifications  
Blank  
Standard  
(3) Conduit Size, Ground Terminal Specifications  
Specifications  
Symbol  
Conduit Size  
Ground terminal presence or absence  
G1/2  
Without ground terminal  
Blank  
(4) Indicator Type  
Symbol  
Specifications  
LD  
LED 10 to 115VAC/VDC  
(5) Lever Type  
Symbol  
Specifications  
Blank  
Allen-head bolt lever (bolt material: stainless)  
A
F
Double nut lever (bolt material: stainless)  
Hexagonal head screw with hexagon socket lever (bolt material: stainless)  
(6) Connector Type  
Specifications  
Voltage  
----  
Symbol  
Shape  
Wiring locations  
Connector pin No. *1  
Blank  
-DGJS  
-DTGJS  
Without connector  
----  
Screw (M12)  
Smart Click  
----  
----  
1
1
2
2
3
3
4
4
DC  
DC  
NC+NO  
NC+NO  
NC:  
NC:  
, NO:  
, NO:  
Pre-wired Connector *2  
*1. Refer to Contact Forms on page 7 for details about connector pin numbers.  
*2. The standard cable length is 0.3 m. Contact your OMRON representative for information about other cable lengths.  
5
WL-N  
Ordering Information  
General-purpose Switches  
Standard Switches  
Actuator  
Roller lever R38  
Roller lever R50  
Roller lever R63  
Item  
Pretravel (PT)  
Model  
WLCA2-N  
WLG2-N  
Model  
WLCA2-7-N  
-----  
Model  
WLCA2-8-N  
-----  
Basic Switches  
15±5°  
+2°  
-1°  
High-sensitivity Switches  
10°  
Actuator  
Adjustable rod lever  
25 to 140 mm  
Adjustable roller lever  
Item  
Pretravel (PT)  
Model  
WLCA12-N  
WLG12-N  
Model  
WLCL-N  
Basic Switches  
15±5°  
+2°  
-1°  
High-sensitivity Switches  
10°  
WLGL-N  
Indicator-equipped Switches  
Actuator  
Roller lever R38  
Roller lever R50  
Roller lever R63  
Indicator  
LED  
Item  
Pretravel (PT)  
Model  
Model  
Model  
Basic Switches 15±5°  
WLCA2-LD-N  
WLCA2-7LD-N  
WLCA2-8LD-N  
High-sensitivi-  
ty Switches  
+2°  
10°  
WLG2-LD-N  
-----  
-----  
-1°  
Actuator  
Adjustable rod lever  
25 to 140 mm  
Adjustable roller lever  
Indicator  
LED  
Item  
Pretravel (PT)  
Model  
Model  
Basic Switches 15±5°  
WLCA12-LD-N  
WLCL-LD-N  
High-sensitivity  
Switches  
+2°  
10°  
WLG12-LD-N  
WLGL-LD-N  
-1°  
6
WL-N  
General-purpose Switches  
Sensor I/O Connector Switches  
Direct-wired Connectors  
Actuator  
Roller lever R38  
Basic Switches High-sensitivity Switches  
Shape  
Voltage  
Wiring locations  
NO  
Connector pin No.  
Model  
Model  
-----  
3
NC  
3
4
1
4
1
WLCA2-LDK13A-N  
WLCA2-LDK43A-N  
WLCA2-LDK13-N  
WLCA2-LDK43-N  
AC  
DC  
2
2
3
3
4
4
NC + NO  
NO  
, NO  
, NO  
-----  
Screw  
WLG2-LDK13-N  
WLG2-LDK43-N  
NC + NO  
NC  
Pre-wired Connectors  
Actuator  
Roller lever R38  
Basic Switches  
Model  
High-sensitivity Switches  
Model  
Shape  
Voltage  
Wiring locations  
Connector pin No.  
1
4
2
2
4
2
2
3 4  
, NO  
AC  
DC  
NC + NO  
NO  
NC  
3
WLCA2-LD-AGJ-N  
WLCA2-LD-M1J-N  
WLCA2-LD-M1GJ-N  
WLCA2-LD-M1JB-N  
-----  
WLG2-LD-AGJ-N  
WLG2-LD-M1J-N  
WLG2-LD-M1GJ-N  
WLG2-LD-M1JB-N  
WLG2-LD-M1TJ-N  
WLG2-LD-M1TJB-N  
Screw  
1
NO  
3
NC  
3
NO  
Smart Click  
3
NC  
-----  
Contact Forms  
Screw Terminal Switches  
Screw Terminal Switches  
Indicator-equipped (Light-ON when Not Operating) Switches *1  
Za  
Internal  
14 (NO)  
13 (NO)  
11 (NC)  
circuits  
Za  
14 (NO)  
12 (NC)  
13 (NO)  
11 (NC)  
12 (NC)  
Direct-wired Connectors/Pre-wired Connectors  
Indicator-equipped (Light-ON when Not Operating) Switches *1  
AC  
Internal  
circuits  
DC  
Internal  
circuits  
Za  
Za  
NO NC  
NC NO  
NO NC  
NC NO  
WL@-@K13A-N  
4
3
WL@-@K13-N  
4
3
1
WL@-@-M1J-N  
WL@-@-M1TJ-N  
WL@-@K43A-N  
WL@-@-AGJ-N  
4
1
2
3
4
WL@-@-M1GJ-N  
1
2 3 4 indicate the connector pin number.  
WL@-@-M1JB-N  
WL@-@-M1TJB-N  
3
2
2
WL@-@K43-N  
4
1
3
Connector Pin Layout Diagram  
AC  
DC  
Positioning piece *2  
Positioning piece *2  
2
2
3
1
3
1
4
4
Note: Leakage current from indicator circuit may cause load's malfunction. Please check the load's OFF current before use the indicator-equipped switch.  
*1. Light-ON when not operating means the indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the  
actuator rotates or is pushed down.  
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.  
7
WL-N  
Connecting Sensor I/O connector cable (Socket)  
Cable length  
L (m)  
Type  
AC/DC Type Number of cable cores  
Model  
Applicable limit switch models  
2 m  
5 m  
2 m  
5 m  
2 m  
5 m  
2 m  
5 m  
XS2F-A421-DB0-F  
XS2F-A421-GB0-F  
XS2F-A421-D90-F  
XS2F-A421-G90-F  
XS2F-D421-DD0  
XS2F-D421-GD0  
XS2F-D421-DA0-F  
XS2F-D421-GA0-F  
2
WL@-@K13A-N  
AC  
WL@-@K43A-N  
WL@-@-AGJ-N  
4
M12 Screw (Straight)  
WL@-@K13-N  
WL@-@-M1J-N  
2
WL@-@-M1GJ@-N  
DC  
2 m  
5 m  
XS2F-D421-D80-F  
XS2F-D421-G80-F  
WL@-@K43-N  
WL@-@-M1JB-N  
4
M12 Smart click type (Straight)  
2 m  
5 m  
XS5F-D421-D80-F  
XS5F-D421-G80-F  
WL@-@-M1TJ-N  
WL@-@-M1TJB-N  
DC  
4
Dimensions (Unit: mm)  
XS2F-@421-@@0-@  
XS2F-D421-@D0  
L (Cable length)  
40.7  
6 dia.  
14.9 dia.  
DC  
AC  
30  
5
50  
Wiring Diagram  
AC/DC Type  
Two-core model  
Wiring Diagram  
Four-core model  
Wiring Diagram  
Model  
Model  
Terminal No.  
Cable color of  
core sheath  
1
2
3
4
XS2F-A421-DB0-F  
XS2F-A421-GB0-F  
XS2F-A421-D90-F  
XS2F-A421-G90-F  
AC  
Brown  
Blue  
Terminal No.  
Cable color of  
core sheath  
Terminal No.  
Cable color of  
core sheath  
1
2
3
4
XS2F-D421-DD0  
XS2F-D421-GD0  
1
2
3
4
Brown  
White  
Blue  
Blue  
Brown  
Black  
XS2F-D421-D80-F  
XS2F-D421-G80-F  
DC  
Terminal No.  
Cable color of  
core sheath  
1
2
3
4
Brown  
XS2F-D421-DA0-F  
XS2F-D421-GA0-F  
Blue  
XS5F-D421-@80-F  
Wiring Diagram  
L (Cable length)  
Four-core model  
AC/DC Type  
40.7  
6 dia.  
Model  
Wiring Diagram  
Terminal No.  
Cable color of  
core sheath  
14.9 dia.  
1
2
3
4
Brown  
White  
Blue  
XS5F-D421-D80-F  
XS5F-D421-G80-F  
DC  
30  
5
Black  
50  
8
WL-N  
Environment-resistant Switches  
Actuator  
Adjustable rod lever  
Roller lever R38  
Adjustable roller lever  
25 to 140 mm  
Item  
Pretravel (PT)  
Model  
WLCA2-TH-N  
WLG2-TH-N  
WLCA2-TC-N  
WLG2-TC-N  
WLCA2-P1-N  
WLG2-P1-N  
Model  
Model  
WLCL-TH-N  
WLGL-TH-N  
WLCL-TC-N  
WLGL-TC-N  
WLCL-P1-N  
WLGL-P1-N  
Basic Switches  
15±5°  
WLCA12-TH-N  
WLG12-TH-N  
WLCA12-TC-N  
WLG12-TC-N  
WLCA12-P1-N  
WLG12-P1-N  
Heat-resistant Switches  
+2°  
-1°  
High-sensitivity Switches 10°  
Basic Switches  
15±5°  
Low-temperature Switches  
+2°  
-1°  
High-sensitivity Switches 10°  
Basic Switches  
15±5°  
Weather-proof Switches  
+2°  
-1°  
High-sensitivity Switches 10°  
Spatter-prevention Selection Switches  
Actuator  
Roller lever R38  
Double Nut Lever  
Allen-head Lever  
Item  
Pretravel (PT)  
Model  
Model  
Basic Switches  
LED  
15±5°  
WLCA2-LDAS-N  
WLG2-LDAS-N  
WLCA2-LDS-N  
WLG2-LDS-N  
+2°  
High-sensitivity Switches 10°  
-1°  
9
WL-N  
Individual Parts  
Switches without levers / Heads / Actuators  
General-purpose  
Switches without  
levers *1  
Heads *2  
(with Actuators)  
Actuators *3  
Model  
Actuator type  
Item  
Pretravel (PT)  
Set model  
Model  
Model  
Basic Switches  
15±5°  
WLCA2-N  
WLG2-N  
WLRCA2-N  
WL-1H1100-N  
Roller lever  
WL-1A100  
WL-2A100  
WL-4A100  
+2°  
-1°  
High-sensitivity Switches 10°  
WLRG2-N  
WLRCA2-N  
WLRG2-N  
WLRCA2-N  
WLRG2-N  
WL-2H1100-N  
WL-1H2100-N  
WL-2H2100-N  
WL-1H4100-N  
WL-2H4100-N  
Basic Switches  
15±5°  
WLCA12-N  
WLG12-N  
WLCL-N  
Adjustable roller lever  
Adjustable rod lever  
+2°  
-1°  
High-sensitivity Switches 10°  
Basic Switches  
15±5°  
+2°  
-1°  
High-sensitivity Switches 10°  
WLGL-N  
*1. The Switches without levers is not compatible with WL-series models.  
*2. The Heads is not compatible with WL-series models.  
*3. The actuator is common use in WL and WL-N.  
Spatter-prevention Switches  
Switches without  
levers *1  
Heads *2  
(with Actuators)  
Actuators *3  
Model  
Actuator type  
Lever Type  
Item  
Set model  
Model  
Model  
Basic Switches  
WLCA2-LDS-N  
WLG2-LDS-N  
WLRCA2-LDS-N  
WLRG2-LDS-N  
WLRCA2-LDS-N  
WLRG2-LDS-N  
Standard lever  
Double nut lever  
WL-1H1100S-N  
WL-1A103S  
WL-1A105S  
High-sensitivity Switches  
Basic Switches  
Roller lever  
WLCA2-LDAS-N  
WLG2-LDAS-N  
WL-2H1100S-N  
High-sensitivity Switches  
*1. The Switches without levers is not compatible with WL-series models.  
*2. The Heads is not compatible with WL-series models.  
*3. The actuator is common use in WL and WL-N.  
Covers with Operation Indicators(See Note.)  
General-purpose  
Cover  
Covers *1  
Model  
Item  
LED  
WL-LD-N  
*1. The cover is not compatible with WL-series models.  
Spatter-prevention Switches  
Cover  
Covers *1  
Model  
Item  
LED  
WL-LDS-N  
*1. The cover is not compatible with WL-series models.  
Note: The default setting is "light-ON when not operating."  
Turn the lamp holder by 180° to change the setting to "light-ON when operating."  
10  
WL-N  
Specifications  
General-purpose/Environment-resistant Switches  
Ratings  
Screw Terminals  
Non-inductive load (A)  
Rated voltage  
Inductive load (A)  
Inductive load Motor load  
NC NO  
Item  
Resistive load  
Lamp load  
(V)  
NC  
NO  
NC  
NO  
NC  
NO  
AC 125  
250  
10  
10  
10  
3
2
1.5  
1.5  
1
0.8  
10  
10  
3
5
3
1.5  
2.5  
1.5  
0.8  
500  
DC  
8
14  
30  
10  
10  
6
6
6
4
3
3
3
10  
10  
6
6
6
4
Basic Switches  
125  
250  
0.8  
0.4  
0.2  
0.1  
0.2  
0.1  
0.8  
0.4  
0.2  
0.1  
AC 125  
250  
5
5
----  
----  
----  
----  
----  
----  
High-sensitivity Switches  
DC 125  
250  
0.4  
0.2  
Note: 1. The above figures are for steady-state currents.  
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).  
3. A lamp load has an inrush current of 10 times the steady-state current.  
4. A motor load has an inrush current of 6 times the steady-state current.  
5. For PC loads, use the microload models.  
30 A max.  
(15 A max. *)  
NC  
Inrush current  
20 A max.  
(10 A max. *)  
NO  
* For high-sensitivity overtravel.  
Minimum applicable load  
5 VDC 1 mA, resistive load, P level  
Indicator-equipped Switches  
Model  
Item  
Max. rated voltage  
10 to 24 VAC/DC  
115 VAC/DC  
Leakage current (mA)  
Approx. 0.4  
Approx. 0.5  
WL-LD-N  
LED  
Characteristics  
Degree of protection  
IP67  
Mechanical  
Electrical  
15,000,000 operations min. *2  
750,000 operations min. *3  
1 mm/s to 1 m/s (in case of WLCA2-N)  
120 operations/minute min.  
30 operations/minute min.  
50/60 Hz  
Durability *1  
Operating speed  
Operating frequency  
Mechanical  
Electrical  
Rated frequency  
Insulation resistance  
Contact resistance  
100 MΩ min. (at 500 VDC)  
25 mΩ max. (initial value for the built-in switch when tested alone)  
1,000 VAC (600 VAC), 50/60 Hz for 1 min  
Between terminals of the same polarity  
Between currentcarrying metal part and ground  
Dielectric strength  
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min  
Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min  
Vibration resistance Malfunction  
10 to 55 Hz, 1.5-mm double amplitude  
1,000 m/s2 max.  
300 m/s2  
Destruction  
Shock  
resistance  
Malfunction  
Ambient operating temperature  
Ambient operating humidity  
Weight  
-10 to +80°C (with no icing) *4  
35% to 95% RH  
Approx. 255 g (in case of WLCA2-N)  
Note: 1. The above figures are initial values.  
2. 2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.  
*1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON  
sales representative for more detailed information on other operating environments.  
*2. Durability is 1,000,000 operations min. for high-sensitivity models.  
500,000 operations min. for weather-proof models.  
*3. Durability is 500,000 operations min. for high-sensitivity models.  
500,000 operations min. for weather-proof models.  
*4. For low-temperature models this is -40°C to +40°C (with no icing). For heatresistant models the range is +5°C to +120°C.  
11  
WL-N  
Spatter-prevention Switches  
Ratings  
Screw Terminals  
Non-inductive load (A)  
Resistive load Lamp load  
NC NO  
Inductive load (A)  
Inductive load Motor load  
NC NO  
Rated voltage  
(V)  
Item  
NC  
NO  
NC  
NO  
AC 115  
10  
3
1.5  
10  
5
2.5  
WL@-LDS-N  
(Without high-sensitivity overtravel models)  
DC  
12  
24  
10  
6
6
4
3
3
10  
6
6
4
115  
0.8  
0.2  
0.2  
0.8  
0.2  
Note: 1. The above figures are for steady-state currents.  
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).  
3. A lamp load has an inrush current of 10 times the steady-state current.  
4. A motor load has an inrush current of 6 times the steady-state current.  
* Refer to the rating of a General-purpose / Weather-proof Switches type for the rating of a high-sensitivity overtravel type.  
NC  
NO  
30 A max.  
20 A max.  
Inrush current  
(Without high-sensitivity overtravel models)  
Operating temperature  
Operating humidity  
-10°C to +80°C (with no icing)  
35 to 95% RH  
Characteristics  
Degree of protection  
IP67  
Mechanical  
Durability *1  
15,000,000 operations min. *2  
Electrical  
750,000 operations min. *3  
Operating speed  
1 mm/s to 1 m/s (in case of WLCA2-@S-N)  
120 operations/minute min.  
Mechanical  
Operating frequency  
Electrical  
30 operations/minute min.  
Rated frequency  
50/60 Hz  
Insulation resistance  
Contact resistance  
100 MΩ min. (at 500 VDC)  
25 mΩ max. (initial value for the built-in switch when tested alone)  
1,000 VAC (600 VAC), 50/60 Hz for 1 min  
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min  
Between terminals of the same polarity  
Dielectric strength  
Between currentcarrying metal part and ground  
Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min  
Vibration resistance Malfunction  
10 to 55 Hz, 1.5-mm double amplitude  
1,000 m/s2 max.  
300 m/s2  
Destruction  
Shock  
resistance  
Malfunction  
Ambient operating temperature  
Ambient operating humidity  
Weight  
-10 to +80°C (with no icing)  
35% to 95% RH  
Approx. 255 g (in case of WLCA2-@S-N)  
Note: 1. The above figures are initial values.  
2. 2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.  
*1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON  
sales representative for more detailed information on other operating environments.  
*2. Durability is 1,000,000 operations min. for high-sensitivity models.  
500,000 operations min. for weather-proof models.  
*3. Durability is 500,000 operations min. for high-sensitivity models.  
500,000 operations min. for weather-proof models.  
12  
WL-N  
General-purpose/ Environment-resistant/ Spatter-prevention Switches  
Approved Standards  
Agency  
Standard  
UL508  
File No.  
Approved models  
UL  
CSA C22.2 No.14  
EN60947-5-1  
GB14048.5  
Contact your OMRON representative for information Contact your OMRON representative for information  
TÜV Rheinland  
CCC (CQC)  
Approved Standard Ratings  
UL/cUL (UL508, CSA C22.2 No.14)  
Specifications  
Approved Standards  
A600  
Indicator  
Sensor I/O connectors  
Item  
Basic Switches  
1 A, 125 VDC  
No Connector  
B600  
0.5 A, 125 VDC  
High-sensitivity Switches  
No indicator  
C300  
3 A, 250 VAC  
Pre-wired Connector (AC)  
Basic Switches and High-sensitivity Switches  
Basic Switches  
1 A, 125 VDC  
Pre-wired Connector (DC)  
Direct-wired Connector (DC)  
High-sensitivity Switches  
0.5 A, 125 VDC  
A150  
Basic Switches  
10 A, 115 VAC  
1 A, 115 VDC  
No Connector  
B150  
High-sensitivity Switches  
5 A, 115 VAC  
0.5 A, 115 VDC  
LED  
C150  
3 A, 115 VAC  
Pre-wired Connector (AC)  
Basic Switches and High-sensitivity Switches  
Basic Switches  
1 A, 115 VDC  
Pre-wired Connector (DC)  
Direct-wired Connector (DC)  
High-sensitivity Switches  
0.5 A, 115 VDC  
A600 Authentication conditions  
Current (A)  
Volt-ampere (VA)  
Rated voltage  
Energizing current  
Make  
Break  
Make  
Break  
120 VAC  
240 VAC  
480 VAC  
600 VAC  
60  
30  
15  
12  
6
3
1.5  
1.2  
10 A  
7,200  
720  
B600 Authentication conditions  
Current (A)  
Volt-ampere (VA)  
Rated voltage  
Energizing current  
Make  
Break  
Make  
Break  
120 VAC  
240 VAC  
480 VAC  
600 VAC  
30  
15  
7.5  
6
3
1.5  
0.75  
0.6  
5 A  
3,600  
360  
A150 Authentication conditions  
Current (A)  
Volt-ampere (VA)  
Rated voltage  
120 VAC  
Energizing current  
10 A  
Make  
Break  
Make  
Break  
60  
6
7,200  
720  
B150 Authentication conditions  
Current (A)  
Volt-ampere (VA)  
Rated voltage  
120 VAC  
Energizing current  
5 A  
Make  
Break  
Make  
Break  
30  
3
3,600  
360  
C150 Authentication conditions  
Current (A)  
Volt-ampere (VA)  
Rated voltage  
120 VAC  
Energizing current  
2.5 A  
Make  
Break  
Make  
Break  
15  
1.5  
1,800  
180  
13  
WL-N  
TUV (EN60947-5-1)  
(Authenticated for ground terminal models and DC connector models only.)  
Specification  
Authentication conditions  
With ground terminals  
With DC Connector  
No indicator  
LED  
Working load category  
AC-15  
250 V  
DC-12  
48 V  
AC-15  
115 V  
DC-12  
48 V  
DC-12  
48 V  
Rated working voltage (Ue)  
Rated working current (Ie)  
2 A  
Conditional short-circuit current  
Short-circuit protective device (SCPD)  
Rated insulation voltage (Ui)  
Rated impulse dielectric strength (Uimp)  
Pollution degree  
100 A  
10 A, fuse type gG  
250 V  
48 V  
4 kV  
800 V  
3
Electric shock protection class  
Class I  
Class III  
CCC (GB14048.5)  
Specification  
LED  
Authentication conditions  
No indicator  
AC-15  
250 V  
With DC Connector With AC Connector  
Working load category  
DC-13  
48 V  
AC-15  
250 V  
DC-13  
48 V  
DC-13  
48 V  
AC-15  
250 V  
Rated working voltage (Ue)  
Rated working current (Ie)  
2 A  
Conditional short-circuit current  
Short-circuit protective device (SCPD)  
Rated insulation voltage (Ui)  
1000 A  
10 A, fuse type gG  
250 V  
14  
WL-N  
Structure and Nomenclature  
Structure  
General-purpose Switches: WLCA2-N  
Actuator  
Head-mounting Screws  
Roller  
The roller is made of self-lubricating  
sintered stainless steel and boasts high  
resistance to wear.  
Head  
Lever  
You can remove the two screws to  
mount the switch in any of the four  
possible orientations.  
The lever forged of anti-corrosive aluminium  
alloy features high corrosion resistances  
and outstanding ruggedness.  
With roller lever, adjustable rod and flexible  
rod models, the actuator position can be set  
anywhere within 360°. (The lever cannot be  
mounted in the opposite direction.)  
Shaft Section Seal  
An oil seal is fitted on the inlet of the  
shaft section to maintain a tight seal.  
Roller Lever Setscrew  
Operational Plunger  
You can change the direction of the  
operational plunger to electrically switch  
the direction of operation between both  
sides, left only, or right only.  
Set Position Marker Plate  
After operation, set the  
indicator needle on the  
marker plate so that is in the  
convex section of the bearing.  
Built-in Switch  
Built-in switch with SPST-NO+NC  
contact form.  
Requires maintenance (excessive overtravel)  
Proper range  
Requires maintenance (insufficient overtravel)  
Proper range  
Terminal Screws  
Four, M3.5 screws  
Requires maintenance (excessive overtravel)  
Cover Setscrew  
Conduit Opening *1  
Phillips screws are used to ensure ease of  
use.  
The conduit screw is a parallel screw  
for G1/2 piping, and is used together  
with an SC connector to maintain a  
tight seal.  
Cover  
Cover Seal  
By using a packing seal as the cover seal, an  
optimum squeeze can be obtained and  
high sealing properties are assured as well.  
*1. The available conduit screws are Pg 13.5, M20 and 1/2-14 NPT.  
15  
WL-N  
Indicators  
Indicator Covers  
Indicator  
The indicator covered if outsert molded  
from diecast aluminum and has outstanding  
sealing properties.  
The indicator is an LED. Models with LED  
indicators have a built-in rectifier stack, so it  
is not necessary to change the polarity.  
Indicator Windows  
Operation (i.e., light-ON when operating or  
light-ON when not operating) depends on  
LED is used.  
Contact Spring  
The built-in switch's terminal screws are  
used to connect the indicator terminal.  
Since the connection spring (coil spring) is  
used for this connection, it will not be  
necessary to connect the indicator terminal.  
When a ground terminal is provided  
however, a lead wire must be used.  
Light-ON when Operating/Not Operating  
Indicators can be switched from light-ON  
when operating and light-ON when not  
operating, by simply rotating the indicator  
holder by 180°.  
Light-ON when Operating  
Light-ON when Not Operating  
LED at top  
LED at bottom  
Operation  
Internal Circuits  
Power  
Rectifier stack  
Contact spring  
Built-in switch  
Rated  
current  
diode  
Za  
Resistor  
Resistor  
14  
12  
13  
11  
Light-ON when  
operating *1  
WL-LD-N  
Zener  
diode  
Load  
Internal  
circuits  
LED  
WL-LD-N  
Power  
Internal  
circuits  
Za  
Light-ON when  
not operating *2  
Load  
14  
12  
13  
11  
Built-in switch  
Note: 1. The indicator cover cannot be replaced on the molded terminals. In all cases the indicator does not light when the load is ON.  
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed  
down.  
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the  
actuator rotates or is pushed down.  
16  
WL-N  
Spatter-prevention Switches: WLCA2-LDS-N  
Actuator  
Roller, Roller Axis  
Using stainless steel prevents  
spatter from adhering.  
Screws  
Operating Lever  
Externally visible screws on the head and  
cover are made of stainless steel to prevent  
spatter adherence.  
A baking finish is applied to the surface  
so that any adhering spatter is easily  
removed.  
Head Cap  
Using fluororesin prevents spatter from  
adhering.  
Roller Lever Setscrew  
Stainless steel construction to prevent  
spatter adherence.  
* Spatter means the zinc powder produced  
when welding.  
Double nut models are also available.  
Adhering spatter to the Limit Switch may  
cause malfunction of lever or lamp cover.  
The lack of gap prevents spatter  
powder from clogging.  
17  
WL-N  
Dimensions and Operating Characteristics  
(Unit: mm)  
General-purpose Models  
Standard Models  
Basic / High-sensitivity  
Roller lever R38  
Basic  
WLCA2-N  
Roller lever R50  
Basic  
WLCA2-7-N  
High-sensitivity  
WLG2-N  
60 max.  
1.5  
53  
67.2 max.  
1.5  
17.5×15 dia. *  
Two, M3.5  
41.5  
40  
17.5×7 dia. *  
Two, M3.5  
1.5  
58.1  
41.5  
25.4  
13.1  
1.5  
1.5  
25.4  
13.1  
12.7  
R50  
12.7  
R38  
Four, 5.2 dia.  
holes  
25.4  
M5  
25.4  
Allen-head bolt  
14.7  
14.7  
(125)  
(137)  
M5  
Allen-head bolt  
Four, 5.2 dia. holes  
0.2  
58.7  
68.7  
68.7  
0.2  
58.7  
Three, M4  
Three, M4  
5
5
21.6  
21.6  
Four, M6  
Depth: 15 min.  
(4.9)  
(4.9)  
1.2  
Four, M6  
Depth: 15 min  
(15.1)  
29.2  
35  
JIS B 0202 G½  
(15.1)  
1.2  
29.2  
JIS B 0202 G½  
0.2  
30.2  
40  
0.2  
35  
42 max.  
0.8  
30.2  
40  
42 max.  
0.8  
0.7  
0.7  
53.2  
53.2  
* Stainless sintered roller  
* Stainless sintered roller  
Only the external appearance of the set position  
indicator plate varies on high-sensitivity models.  
Roller lever R63  
Basic  
WLCA2-8-N  
Adjustable roller lever  
Basic  
WLCA12-N  
High-sensitivity  
WLG12-N  
60 max.  
53  
17.5×7 dia. *  
1.5  
67 max.  
17.5×7 dia. *  
1.5  
60  
1.5  
41.5  
25.4  
13.1  
1.5  
41.5  
25.4  
13.1  
R63  
Two, M3.5  
Two, M3.5  
M5  
12.7  
Adjustable range:  
25 to 89  
12.7  
Allen-head bolt  
Four, 5.2 dia.  
holes  
(150)  
14.7  
Four, 5.2 dia. holes  
25.4  
25.4  
M5  
Allen-head  
bolt  
14.7  
0.2  
68.7  
58.7  
Three, M4  
68.7  
0.2  
Three, M4  
58.7  
5
5
21.6  
(4.9)  
(4.9)  
21.6  
Four, M6  
(15.1)  
Four, M6  
Depth: 15 min  
(15.1)  
1.2  
29.2  
JIS B 0202 G½  
1.2 Depth: 15 min  
29.2  
35  
0.2  
30.2  
40  
0.2  
30.2  
40  
35  
42 max.  
0.8  
0.7  
JIS B 0202 G½  
0.7  
42 max.  
53.2  
0.8  
65.2  
* Stainless sintered roller  
* Stainless sintered roller  
Only the external appearance of the set position  
indicator plate varies on high-sensitivity models.  
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.  
Model  
WLCA2-N  
WLG2-N  
WLCA2-7-N  
WLCA2-8-N  
Operating characteristics  
Operating force  
Release force  
Pretravel  
Overtravel  
Movement Differential MD max.  
OF max.  
RF min.  
PT  
13.34 N  
1.18 N  
15±5°  
70°  
13.34 N  
10.2 N  
0.9 N  
15±5°  
70°  
8.04 N  
0.71 N  
15±5°  
70°  
1.18 N  
+2°  
1°  
10°  
OT min.  
80°  
7°  
12°  
12°  
12°  
Model  
WLCA12-N *1  
WLG12-N *1  
Operating characteristics  
Operating force  
Release force  
Pretravel  
Overtravel  
Movement Differential MD max.  
OF max.  
RF min.  
PT  
13.34 N  
1.18 N  
15±5°  
70°  
13.34 N  
1.18 N  
+2°  
1°  
10°  
OT min.  
80°  
7°  
12°  
*1. The operating characteristics for WLCA12 -N and WLG12-N are measured at the lever length of 38 mm.  
18  
WL-N  
Basic / High-sensitivity  
Adjustable rod lever 25 to 140 mm  
Basic  
WLCL-N  
High-sensitivity  
WLGL-N  
9
55 max.  
1.5  
46  
3±0.2 dia.  
(length:160) *  
1.5  
41.5  
25.4  
13.1  
12.7  
Adjustable range:  
25 to 140  
M8  
Allen-head  
set screw  
Two, M3.5  
Four, 5.2 dia.  
holes  
25.4  
14.7  
M5  
Allen-head  
set screw  
68.7  
Three, M4  
0.2  
58.7  
5
(4.9)  
Four, M6  
Depth: 15 min.  
21.6  
(15.1)  
1.2  
29.2  
0.2  
JIS B 0202 G½  
30.2  
40  
35  
42 max.  
0.7  
* Stainless steel rod  
Only the external appearance of the set position  
indicator plate varies on high-sensitivity models.  
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.  
Model  
WLCL-N *1  
WLGL-N *1  
Operating characteristics  
Operating force  
Release force  
Pretravel  
Overtravel  
Movement Differential MD max.  
OF max.  
RF min.  
PT  
1.39 N  
0.27 N  
15±5°  
70°  
2.84 N  
0.25 N  
+2°  
1°  
10°  
OT min.  
80°  
7°  
12°  
*1. The operating characteristics for WLCL-N and WLGL-N are measured at the lever length of 140 mm.  
19  
WL-N  
Sensor I/O connector Models  
(For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 8.)  
Direct-wired Connector  
Pre-wired  
Roller lever  
WLCA2-LDK13-N  
Roller lever  
WLCA2-LD-M1J-N  
60 max.  
1.5  
53  
41.5  
25.4  
17.5×7 dia. *  
1.5  
60 max.  
1.5  
53  
41.5  
40  
17.5×7 dia. *  
1.5  
13.1  
12.7  
1.5  
Two, M3.5  
25.4  
13.1  
R38  
Four, 5.2 dia. holes  
Two, M3.5  
12.7  
25.4  
R38  
M5  
14.7  
Four, 5.2 dia. holes  
Allen-head bolt  
25.4  
(125)  
M5  
Allen-head  
bolt  
14.7  
68.7  
(125)  
58.7  
0.2  
58.7  
Three, M4  
68.7  
0.2  
Three, M4  
5
(4.9)  
(15.1)  
5
12.5  
Four, M6  
Depth: 15 min  
SC-1M  
21.6  
JIS B 0202 G½  
(4.9)  
Four, M6  
Depth: 15 m  
(15.1)  
1.2  
29.2  
+100  
50  
300  
0.2  
35  
30.2  
40  
M12×1  
42 max.  
0.7  
0.8  
53.2  
* Stainless sintered roller  
XS2H-D421  
35  
42 max.  
0.2  
30.2  
40  
0.7  
0.8  
53.2  
* Stainless sintered roller  
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.  
2. The following diagrams are for a indicator-equipped models.  
Model  
WLCA2-LDK13-N  
WLCA2-LD-M1J-N  
Operating characteristics  
Operating force  
Release force  
Pretravel  
Overtravel  
Movement Differential MD max.  
OF max.  
RF min.  
PT  
13.34 N  
1.18 N  
15±5°  
70°  
OT min.  
12°  
Operation indicator Models  
Roller lever  
WLCA2-LD-N  
60 max.  
1.5  
53  
41.5  
40  
17.5×7 dia. *  
Two, M3.5  
1.5  
1.5  
25.4  
13.1  
12.7  
R38  
Four, 5.2 dia. holes  
25.4  
14.7  
M5  
(125)  
Allen-head bolt  
0.2  
58.7  
68.7  
Three, M4  
5
21.6  
(4.9)  
1.5  
JIS B 0202 G½  
29.2  
(15.1)  
Four, M6  
Depth: 15 min  
35  
42 max.  
0.8  
0.2  
30.2  
40  
0.7  
53.2  
* Stainless sintered roller  
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.  
Model  
WLCA2-LD-N  
Operating characteristics  
Operating force  
Release force  
Pretravel  
Overtravel  
Movement Differential MD max.  
OF max.  
RF min.  
PT  
13.34 N  
1.18 N  
15±5°  
70°  
OT min.  
12°  
20  
WL-N  
Spatter-prevention Models  
Roller lever  
Roller lever  
(Screw terminals)  
WLCA2-LDS-N  
17.5×7 dia. *  
(Pre-wired Connectors)  
WLCA2-LDS-M1J-N  
60 max.  
1.5  
53  
41.5  
60 max.  
17.5×7 dia. *  
Two, M3.5  
1.5  
1.5  
53  
41.5  
40  
1.5  
25.4  
13.1  
12.7  
1.5  
25.4  
13.1  
R38  
Two, M3.5  
R38  
Four, 5.2 dia. holes  
12.7  
25.4  
Four, 5.2 dia. holes  
M5  
14.7  
25.4  
Allen-head bolt  
(125)  
14.7  
M5  
(125)  
Allen-head bolt  
0.2  
68.7  
58.7  
Three, M4  
0.2  
68.7  
58.7  
Three, M4  
5
(4.9)  
5
(15.1)  
(4.9)  
21.6  
(15.1)  
JIS B 0202 G½  
Four, M6  
Depth: 15 min  
SC-1M  
1.2  
29.2  
0.2  
30.2  
40  
+100  
50  
35  
300  
0.7  
42 max.  
0.8  
53.2  
* Stainless sintered roller  
XS2H-D421  
35  
42 max.  
0.2  
30.2  
40  
0.7  
0.8  
53.2  
* Stainless sintered roller  
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.  
Model  
WLCA2-LDS-N  
Operating characteristics  
WLCA2-LDS-M1J-N  
Operating force  
Release force  
Pretravel  
Overtravel  
Movement Differential MD max.  
OF max.  
RF min.  
PT  
13.34 N  
1.18 N  
15±5°  
70°  
OT min.  
12°  
21  
WL-N  
Actuators (Levers Only)  
Lever: Only rotating lever models are illustrated.  
WL-1A100  
WL-1A115  
WL-1A400  
WL-1A118  
Standard Lever  
Resin Roller  
Bearing Roller  
Nylon Roller:  
Roller Width: 30 mm  
17.5 dia. (length: 30)  
17.9  
12.6  
17.9  
12.6  
16.9  
12.1  
0.8  
17.5 dia. (length: 7)  
stainless sintered alloy roller  
17 dia. (length: 6)  
bearing roller  
40.2  
17.5 dia. (length: 7)  
resin roller  
Nylon roller  
23.6  
7.3-dia.  
7.3-dia.  
mounting  
holes  
7.3-dia.  
mounting  
holes  
R38  
mounting  
54.8  
38 54.8  
holes  
38 54.8  
38 54.8  
7.3-dia.  
mounting  
holes  
M5  
Allen-head bolt  
M5  
M5  
Allen-head bolt  
M5  
16  
16  
16  
16  
11.4  
Allen-head bolt  
Allen-head bolt  
11.4  
11.4  
11.4  
WL-1A105  
Double Nuts  
WL-1A103S  
Spatter  
WL-1A200  
Lever Length: 50  
Roller Width: 15  
WL-1A300  
Lever Length: 63  
17.9  
12.6  
17.5 dia. (length: 15)  
stainless steel roller  
17.9  
12.6  
17.9  
12.6  
17.5 dia. (length: 7)  
stainless steel roller  
17.5 dia. (length: 7)  
stainless sintered alloy roller  
17.5 dia. (length: 7)  
stainless sintered alloy roller  
25.7  
16.6  
7.3-dia.  
mounting  
holes  
7.3-dia.  
mounting  
7.3-dia.  
mounting  
holes  
0.2  
38  
54.8  
38 54.8  
holes  
50 66.8  
0.3  
7.3-dia.  
mounting  
holes  
63  
79.8  
M5  
Two, M5  
Allenhead nut  
and arm set screw  
16  
16  
Allen-head bolt  
11.4  
11.4  
M5  
16  
Allen-head bolt  
11.4  
M5  
16  
Allen-head bolt  
11.4  
WL-2A100  
WL-2A111  
WL-2A107  
WL-2A108  
Resin Roller  
Double Nuts  
Resin Roller  
0.8  
0.8  
24.9  
19.7  
0.8  
0.8  
0.8  
24.9  
19.7  
24.9  
17.5 dia. (length: 7)  
stainless sintered M5  
alloy roller  
17.5 dia. (length: 7)  
stainless sintered alloy roller  
17.5 dia. (length: 7)  
resin roller  
M5  
Allen-head  
bolt  
0.8  
0.8  
17.5 dia. (length: 7)  
resin roller  
24.9  
19.7  
0.8  
19.7  
Allen-head  
bolt  
Adjustable lever:  
stainless steel  
Adjustable lever:  
stainless steel  
Adjustable lever:  
stainless steel  
Adjustable lever:  
stainless steel  
23  
Adjustable  
range:  
25 to 140  
23  
Adjustable  
range:  
25 to 89  
Adjustable  
range:  
25 to 89  
Adjustable  
range:  
28 to 88  
105.75  
M5  
105.75  
M5  
105.75  
7.3-dia.  
mounting  
holes  
7.3-dia.  
mounting  
holes  
155.75  
7.3-dia.  
mounting  
holes  
7.3-dia.  
mounting  
holes  
Allen-head  
bolt  
Allen-head  
bolt  
12  
16  
12  
16  
Two, M5 Allen-head nut  
and arm set screw  
12  
16  
6.2  
(15.8)  
WL-2A122  
WL-2A106  
WL-2A130  
WL-2A104  
0.8  
0.8  
0.8  
0.8  
24.9  
19.7  
17.5 dia. (length: 7)  
stainless sintered  
alloy roller  
24.9  
0.8  
0.8  
24.9  
19.7  
24.7  
19.5  
M5  
Allen-head  
bolt  
17.5 dia. (length: 7)  
stainless sintered  
alloy roller  
17.5 dia. (length: 7)  
stainless sintered  
alloy roller  
0.8  
50 dia. (length: 6)  
Nylon roller  
0.8  
19.7  
9.1  
Adjustable lever:  
stainless steel  
3
Adjustable lever:  
stainless steel  
23  
(21.8)  
(10)  
Adjustable  
range:  
25 to 140  
23  
Adjustable  
range:  
25 to 89  
R89.5  
Adjustable  
from 42 to 89  
(10)  
7.3-dia.  
mounting  
holes  
Three, 5.3+0.2  
105.75  
M5  
(112)  
0
155.75  
dia. holes  
7.3+0.1  
7.3-dia.  
mounting  
holes  
0
7.3-dia.  
mounting  
holes  
mounting holes  
M5  
Allen-head  
bolt  
Allen-head  
bolt  
Two, M5  
(length: 16)  
Allen-head bolt  
15.9  
20  
16  
20  
22.1  
23  
12  
16  
*
Can be installed  
on the rear side.  
6.2  
(15.8)  
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.  
22  
WL-N  
Lever: Only rotating lever models are illustrated.  
WL-2A110 WL-2A105  
WL-1A106  
WL-1A110  
34.2  
24.2  
34.5  
24.4  
35 dia. (length: 6)  
Nylon roller  
50 dia. (length: 6)  
Nylon roller  
0.8  
49 dia. rubber roller  
Material: NBR  
0.8  
20.1  
20.1  
50 dia. (length: 15)  
Nylon roller  
6
R38  
R38  
23  
Adjustable  
Adjustable  
from 41 to  
78.5  
122  
from 41 to  
89  
7.3+0.1 dia.  
mounting  
holes  
M5  
Allen-head  
bolt  
0
16  
7.3-dia.  
mounting  
holes  
11.5  
16  
11.5  
M5  
Allen-head  
bolt  
M5  
Allen-head  
bolt  
7.3-dia.  
mounting  
holes  
7.3-dia.  
mounting  
holes  
16  
16  
WL-4A100  
WL-4A201  
WL-3A100  
WL-3A106  
Double Nut  
9
3.2-dia.  
stainless  
steel rod  
9
3.2-dia.  
stainless steel rod  
2-dia. stainless  
steel for spring  
3-dia. stainless  
steel rod  
7.3-dia. mounting  
holes  
M5  
Adjustable  
from 350  
to 380  
Adjustable  
from 350  
to 380  
7.3-dia.  
13  
Adjustable  
from  
25 to 140  
mounting holes  
Adjustable  
from 270 to  
290  
Allen-head  
bolt  
8
8
2
400  
2
400  
160  
M5  
Allen-head  
bolt  
19  
Actuator's  
center of  
rotation  
2
65  
2
65  
11  
11  
7.5  
7.5  
6
6
11  
7.3-dia.  
mounting  
holes  
7.3-dia.  
mounting  
holes  
Two, M5  
Allenhead  
nut and arm  
set screw  
11  
M5  
Allen-head  
bolt  
13.4  
25.5 max.  
13.4  
12.8  
12.8  
25.5 max.  
WL-3A108  
WL-3A200  
WL-3A203  
WL-4A112  
2.3-dia.  
operation rod  
9
8 dia.  
Cap  
3.2-dia.  
stainless steel rod  
4-dia. stainless  
steel rod  
50  
7.3-dia.  
mounting holes  
Adjustable  
from 650  
to 660  
M5  
Allen-head  
bolt  
Adjustable  
up to 141  
2
417.5  
0.4  
8
±2  
437.5  
Adhesive  
4
450  
680  
160  
±4  
470  
12.5 dia. max.  
11  
19  
12.5  
dia.  
max.  
2.3-dia.  
operation  
rod  
(95)  
2
65  
11  
(95)  
7.5  
7.5  
6
11  
7.5  
6
6
7.3-dia.  
mounting  
holes  
7.3-dia.  
mounting  
holes  
11  
M5  
Allen-head  
bolt  
M5  
Allen-head  
13  
13.4  
7.5  
12.8  
7.3-dia.  
mounting  
holes  
M5  
Allen-head  
bolt  
bolt  
13  
24.6 max.  
25.5 max.  
24.6 max.  
WL-2A129  
WL-5A101  
WL-5A103  
WL-5A105  
15.8  
3
Two, 17.5 dia. (length: 7)  
stainless sintered alloy rollers  
Two, 17.5 dia. (length: 7)  
stainless sintered alloy rollers  
Two, 17.5 dia. (length: 7)  
stainless sintered alloy rollers  
6.7  
17.7  
Marking  
(18.5)  
17.7  
17.7  
12.4  
R8  
6.7  
1.3  
12.4  
12.4  
1.3  
90°  
90°  
90°  
Three, 5.3+0.2  
0
7.3+0.1dia.  
dia. holes  
7.3+0.1dia.  
0
7.3+0.1 dia.  
0
0
R38  
54.8  
R38  
54.8  
R38  
54.8  
84  
95.3  
7.3+0.1 dia.  
mou0nting  
holes  
(108)  
10  
10  
M5 (length: 16)  
Allen-head bolt  
M5 (length: 16)  
Allen-head bolt  
M5 (length: 16)  
Allen-head bolt  
11  
11  
11  
11.3  
15.9  
20  
Two,M5  
(length: 16)  
Allen-head bolts  
WL-5A104 has a plastic roller  
WL-5A100 has a plastic roller  
WL-5A102 has a plastic roller  
22.1  
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.  
2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards.  
Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur.  
23  
WL-N  
Safety Precautions  
Precautions for Safe Use  
Precautions for Correct Use  
Environment  
Take special care to use where there is fine powder, mud and/or  
foreign materials stacking. And check the condition with actual  
using condition before using. Then use without a performance  
problem.  
This switch is only for indoor use. If it is used in outdoor, it may be  
cause of switch failure.  
Do not keep the Switch in locations with corrosive gas, such as  
sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),  
or chlorine gas (Cl2), or high temperature and humidity. Otherwise,  
contact failure or corrosion damage may result.  
Seal material may deteriorate if a Switch is used outdoor or where  
subject to special cutting oils, solvents, or chemicals. Always  
appraise performance under actual application conditions and set  
suitable maintenance and replacement periods.  
Install Switches where they will not be directly subject to cutting  
chips, dust, or dirt. The Actuator and Switch must also be protected  
from the accumulation of cutting chips or sludge.  
Be sure to ground. If not, there is the possibility that electrical shock  
occurs.  
Do not touch charged switch terminals while the switch has carry  
current, otherwise there is the possibility that electrical shock  
occurs.  
Do not disassemble the limit switch or touch inside of it under  
supplying power, otherwise there is the possibility that electrical  
shock occurs.  
Do not touch the wire or rod type actuator in order to prevent injury.  
Connect a fuse which has 1.5 to 2 times higher breaking current  
than the switch rated current to the switch in series in order to  
prevent the switch from short-circuit damage.  
On the occasion when using the switch with GB ratings, use a 10A  
fuse that complies IEC60269, either type gG.  
The durability of switch is depends on the operating condition.  
Be sure to check the condition with actual using condition before  
using, and use with the number of times of operating without a  
performance problem.  
Do not drop the switch. Otherwise, there is the possibility that the  
switch functions may be spoiled.  
Not Suitable  
Suitable  
Do not connect a Single Limit Switch to two power supplies that are  
different in polarity or type.  
Be sure to keep the load current less than the rated value.  
Otherwise, there is the possibility that the switch may be damage  
and/or burnout.  
Do not use the Switch by itself in atmospheres containing  
flammable or explosive gases. Arcs and heating resulting from  
switching may cause fire or explosion.  
Be sure to prevent the foreign materials such like a scrapped cable  
intrusion in to the switch when wiring. Otherwise, there is the  
possibility of spoiling the normal operation.  
Never wire to the wrong terminals.  
Do not store or use the switch with following place.  
Where the temperature fluctuates greatly  
Constantly subjecting a Switch to vibration or shock can result in  
wear, which can lead to contact interference with contacts,  
operation failure, reduced durability, and other problems.  
Excessive vibration or shock can lead to false contact operation or  
damage. Install Switches in locations not subject to shock and  
vibration and in orientations that will not produce resonance.  
The Switches have physical contacts. Using them in environments  
containing silicon gas will result in the formation of silicon oxide  
(SiO2) due to arc energy. If silicon oxide accumulates on the  
contacts, contact interference can occur. If silicon oil, silicon filling  
agents, silicon cables, or other silicon products are present near  
the Switch, suppress arcing with contact protective circuits (surge  
killers) or remove the source of silicon gas.  
Where the humidity is very high and condensation may occur.  
Where the vibration is too much  
Where receiving direct sunshine.  
Where receiving salty wind.  
Do not disassemble and/or modify the switch at anytime.  
Otherwise, there is the possibility of spoiling the normal operation.  
Do not apply the force such like deformation and/or degeneration  
to the switch. Otherwise, there is the possibility that the switch  
functions may be spoiled.  
Installing the Switch  
To install the Switch, make a mounting panel, as shown in the  
following diagram, and tighten screws using the correct torque.  
Front Mountig : Four, 5.2+0.2 dia. holes  
0
or M5 tapped holes  
0.15  
58.7  
Rear Mountig : Four, 6.2+0.2 dia. holes  
0
0.15  
30.2  
24  
WL-N  
Overtravel Markers  
Tightening Torque  
To allow the roller lever type actuator to travel properly, set the  
roller lever according to the dog or cam stroke so that the  
arrowhead of the lever is positioned within overtravel markers as  
shown.  
If screws are too loose they can lead  
to an early malfunction of the Switch,  
so ensure that all screws are  
tightened using the correct torque.  
In particular, when changing the  
direction of the Head, make sure that  
all screws are tightened again to the  
correct torque. Do not allow foreign  
objects to fall into the Switch.  
(1)  
(6)  
(3)  
Screw down  
Head  
Arrowhead  
(4)  
(2)  
Excessive OT  
Setting range  
Shortage OT  
Setting range  
Excessive OT  
(5)  
Connectors  
No.  
Type  
Torque  
Screw type  
M3.5 screw  
M4 screw  
Tighten the connector with the appropriate torque to prevent  
deformation.  
Use the OMRON type SC connector series, which is prepared  
separately, suitable for outer diameter of cable and inner diameter  
of seal rubber.  
0.78 to 0.88  
N•m  
(1) Head mounting screw  
(2) Cover mounting screw  
1.18 to 1.37  
N•m  
Allen-head bolt  
(3)  
4.90 to 5.88 M5 hexagon socket  
N•m head cap screw  
Make sure to wrap the connector with the seal tape, except the  
connector which has O-ring, to keep the sealability.  
To conform to CSA, use a CSA certified water tight treated conduit  
hub.  
Even when the connector is assembled and set correctly, the end  
of the cable and the inside of the Switch may come in contact. This  
can lead to malfunction, leakage current, or fire, so be sure to  
protect the end of the cable from splashes of oil or water and  
corrosive gases.  
(for securing the roller lever)  
Allen-head bolt  
(3) (for securing the adjustable  
rod lever)  
0.88 to 1.08 M8 hexagon socket set  
N•m  
screw  
0.59 to 0.78  
N•m  
(4) Terminal screw  
(5) Connector  
M3.5 screw  
1.77 to 2.16 G1/2orPg13.5orM20or  
N•m 1/2-14NPT  
4.90 to 5.88 M5 hexagon socket  
N•m head cap screw  
(6) Unit mounting screw  
Microload Applications  
The switch contacts can be used both for standard loads and  
microloads, but once a contact has been used to open and close a  
load it can no longer be used for lower loads. Doing so will damage  
the contact surface and reduce contact reliability.  
If an inrush current or other sudden load occurs during a switch  
operation, the switch will begin to degrade severely which can  
result in reduced durability.  
Wring  
In the case of mounting screw  
Use M3.5-nylon insulation covered crimp terminals (round type) for  
wiring.  
Ex.) V1.25-M3.5(RAP1.25-3.5) (J.S.T. Mfg. Co.,Ltd.)  
Appropriate wire size is AWG16 (1.25mm2).  
Do not supply electric power when wiring.  
Otherwise electric shock may result.  
Do not pull out the wires with excessive force.  
It may cause of coming off the wire.  
Use a contact protection circuit if required.  
Minimum operating load: 5 VDC 1 mA, resistive load, P level  
Note: The P level indicates the standard malfunction level at a  
reliability level of 60% (λ60).  
(JISC5003) λ60 = 0.1 × 10-6 per operation, which indicates an  
estimated malfunction of 1 out of every 10,000,000 operations  
at a reliability level of 60%.  
Use crimp terminals for wiring.  
In the case of lump unit, to avoid interference  
between lump unit and crimp terminals, wire  
according to right wiring figure.  
Indicator  
Attach the lump unit spring to terminal screw  
certainly otherwise itÅfs possible to be destroyed  
or shorted.  
Indicator-equipped switch has contacts and indicator in parallel.  
When contacts are open, leakage current flows through the indicator  
circuit and may cause load's malfunction.  
The ground terminal is only installed on models  
with ground terminals.  
Please check the load's OFF current before use the indicatorequipped  
switch.  
Others  
In the case of prewired connecter and direct connecter  
Holding the connecter certainly when pulling connecter.  
Don’t pull the cable holding it.  
For long term (over a year) storage, check according to Operating  
characteristics, Contact resistance and Dielectric strength at least.  
And check with using condition.  
How to handle  
Changing direction of the head  
By removing the screws in the two corners of the head, the head  
can be set any of four directions. Be sure to change the plunger for  
internal operations at the same time.  
Built-in Switch  
Do not remove or replace the built-in switch.  
25  
WL-N  
Using the Switches  
Item  
Applicable models and Actuators  
Details  
Changing the Installation Position  
of the Actuator  
By loosening the Allen-head bolt on  
the actuator lever, the position of the  
actuator can be set anywhere within  
the 360°.  
Roller Levers:  
WLCA2-N, WLG2-N  
Loosen the Allen-head bolt, set  
the actuator's position and then  
tighten the bolt again.  
With Indicator-equipped Switches, the Adjustable Roller Levers:  
actuator lever comes in contact with  
the top of the indicator cover, so use  
caution when rotating and setting the  
lever.  
WLCA12-N, WLG12-N  
Adjustable Rod Levers:  
WLCL-N, WLGL-N  
When the lever only moves forwards  
and backwards, it will not contact the  
lamp cover.  
Loosen the screws.  
Head  
Changing the Orientation of the  
Head  
Roller Levers:  
WLCA2-N, WLG2-N  
By removing the two screws of the  
Head, the Head can be set in any of  
the four directions.  
Be sure to change the plunger for  
internal operations at the same time.  
Adjustable Roller Levers:  
WLCA12-N, WLG12-N  
Adjustable Rod Levers:  
WLCL-N, WLGL-N  
The output of the Switch will be  
changed, regardless of which  
direction the lever is pushed.  
The output of the Switch will  
only be changed when the lever  
is pushed in one direction.  
Operating Operating Not operating Operating  
Operating  
Not operating  
Roller Levers:  
WLCA2-N, WLG2-N  
Changing the Operating Direction  
By removing the Head on models  
which can operate on one-side only,  
and then changing the direction of the  
operational plunger, one of three  
operating directions can be selected.  
Adjustable Roller Levers:  
WLCA12-N, WLG12-N  
Adjustable Rod Levers:  
WLCL-N, WLGL-N  
Operation in both  
directions  
Clockwise operation  
Counterclockwise  
operation  
Installing the Roller on the Inside  
By installing the roller lever in the  
opposite direction, the roller can be  
installed on the inside.  
(Set so that operation can be  
completed within a 180° level range.)  
Roller Levers:  
WLCA2-N, WLG2-N  
Loosen the  
Allen-head bolt.  
Loosen this  
Adjustment  
Allen-head bolt  
and adjust the  
length of the rod.  
range radius:  
24 to 140 mm  
Loosen this  
Adjustment  
range radius:  
25 to 89 mm  
Allen-head bolt  
and adjust the  
length of the  
lever.  
Adjusting the Length of the Rod or  
Lever  
The length of the rod or lever can be  
adjusted by loosening the Allen-head  
bolt.  
Adjustable Roller Levers:  
WLCA12-N, WLG12-N  
Adjustable Rod Levers:  
WLCL-N, WLGL-N  
Adjustable Roller Levers:  
Adjustable Rod Levers:  
26  
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have  
any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing  
by Omron). Omron disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE  
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL  
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products  
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,  
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the  
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price  
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other  
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,  
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by  
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or  
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system  
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in  
writing, are not to be construed as an amendment or addition to the above warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is  
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,  
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with  
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it  
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice  
to change part numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be  
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to  
confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
OMRON Corporation  
Tokyo, JAPAN  
Industrial Automation Company  
Authorized Distributor:  
Contact: www.ia.omron.com  
Regional Headquarters  
OMRON EUROPE B.V.  
Wegalaan 67-69-2132 JD Hoofddorp  
The Netherlands  
OMRON ELECTRONICS LLC  
One Commerce Drive Schaumburg,  
IL 60173-5302 U.S.A.  
Tel: (31)2356-81-300/Fax: (31)2356-81-388  
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787  
© OMRON Corporation 2013 All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China Tower,  
200 Yin Cheng Zhong Road,  
OMRON ASIA PACIFIC PTE. LTD.  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra Technopark,  
CSM_1_1_1013  
Cat. No. C147-E1-01  
Printed in Japan  
1013 (1013) (W)  
PuDong New Area, Shanghai, 200120, China  
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
Singapore 119967  
Tel: (65) 6835-3011/Fax: (65) 6835-2711  

相关型号:

WLCL-N

Snap Acting/Limit Switch
OMRON

WLCL-TH-N

Snap Acting/Limit Switch
OMRON

WLCL-TS

Analog Circuit
OMRON

WLCLG

GRENZTASTER 2POL EINST STANGENHEBEL
ETC

WLCM0603

Multi-Layer Ceramic High Frequency Inductors
WALSIN

WLCM0603TG

Particular ceramic material and coil structure provide high frequency application range up to 10GHz
WALSIN

WLCM0603TGB12NTB

Particular ceramic material and coil structure provide high frequency application range up to 10GHz
WALSIN

WLCM0603TGB1N2TB

Particular ceramic material and coil structure provide high frequency application range up to 10GHz
WALSIN

WLCM0603TGBR10TB

Particular ceramic material and coil structure provide high frequency application range up to 10GHz
WALSIN

WLCM0603TGC12NTB

Particular ceramic material and coil structure provide high frequency application range up to 10GHz
WALSIN

WLCM0603TGC1N2TB

Particular ceramic material and coil structure provide high frequency application range up to 10GHz
WALSIN

WLCM0603TGCR10TB

Particular ceramic material and coil structure provide high frequency application range up to 10GHz
WALSIN