XG4A-3432 [OMRON]

Board Connector;
XG4A-3432
型号: XG4A-3432
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Board Connector

连接器
文件: 总20页 (文件大小:2240K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Flat Cable Connectors  
XG4  
The Mainstream of Circuit Board  
Connectors conforming MIL Standards  
with Improved Design.  
*
Our new production system improves reliability.  
Space-saving Box-type Plugs (XG4C) available.  
IDC Plugs (XG4E) can be used for relaying.  
An endless number of combinations can be made  
using the XG-5 IDC Connectors for discrete wires,  
XG8 Original Plugs, and the XG2 IDC Connectors  
for PCBs.  
The Original Plugs (XG8) and the Box-type Plugs  
(XG4C) can be locked using Lock Levers.  
Conform to MIL standards (MIL-C-83503).  
UL standards (file No. E103202) (All XG4 models  
* Excluding XG4U  
except those with XG4U)  
RoHS Compliant  
Terminology  
z MIL standard  
z Standoff  
Abbreviation for Military Standard. To unify the compatibil-  
ity and quality assurance condition of each company, MIL-  
C-83503 (applicable to connectors) was established in  
1977.  
Part provided for lifting the housing from the board (This  
part improves airflow at the through-hole for better assem-  
bly.)  
z Open-end cover  
An open-end cover has a structure where a flat cable can  
be pulled out from both sides of the cover when a cable is  
attached to a connector. (The cover having a structure  
where a flat cable can be pulled out from only one side of  
the cover is called a "Closed-end cover.")  
Ordering Information  
Model  
XG4M  
XG4M  
XG4T  
XG4A  
MIL plugs  
XG4A  
XG4E  
XG4S  
XG4C  
XG4H  
XG4M-U  
Appear-  
ance  
MIL sockets  
with strain relief  
(with lock)  
MIL sockets with  
strain relief  
Plugs with  
dual ports  
IDC plugs with  
strain relief  
Box-type plugs  
Board-to-board  
sockets  
Page  
3
4
5 to 10  
11 to 12  
13 to 14  
15 to 16  
17 to 18  
Cross-sectional View  
Ratings and Characteristics  
of Terminal  
Item  
MIL Sockets: XG4M  
Relay Plug: XG4E  
MIL Plugs: XG4A  
Box-type Plugs: XG4C  
XG4A  
Board-to-board Sockets: XG4H  
XG4C  
XG4H  
Rated current  
1 A  
250 VAC  
3 A (See note 1.)  
300 VAC  
Rated voltage  
Contact resistance  
Insulation resistance  
Dielectric strength  
Total insertion force  
Removal force  
20 mΩ max. (at 20 mV, 100 mA max.)  
1,000 MΩ min. (at 500 VDC)  
500 VAC for 1 min (leakage current: 1 mA max.)  
0.65 dia.  
0.7 dia.  
1.96 N max. per contact  
0.39 N min. (with test gauge, t= 0.64 mm)  
50 times  
Insertion durability  
Ambient operating  
temperature  
55 to 105°C (with no icing at low temperature)  
Note:  
1. The rated current will depend on the Socket you are using. It is 1 A using the XG4M for example.  
1
Materials and Finish  
Item  
MIL Plugs: XG4A  
Box-type Plugs: XG4C  
IDC Plugs: XG4E  
(Strain Relief: XG4S)  
MIL Sockets: XG4M  
(Strain Relief: XG4T)  
Board-to-board  
Sockets: XG4H  
Housings  
Covers  
Fiber-glass reinforced PBT resin (UL94 V-0)/black  
---  
Polyamide resin (UL94 V-0)/  
black  
Fiber-glass reinforced PBT  
resin (UL94 V-0)/black  
---  
---  
Contacts  
Mating end  
Brass/nickel base, 0.15-μm  
Phosphor bronze/nickel base, 0.15-μm gold plating  
gold plating  
Terminal Press fit Brass/nickel base, 2.0-μm tin  
Phosphor bronze/nickel base, 2.0-μm tin plating  
plating  
Strain Reliefs  
---  
Polyamide resin (UL94 V-0)/  
black  
Fiber-glass reinforced PBT  
resin (UL94 V-0)/black  
Applicable Wires  
For pressing  
1.27-mm pitch flat cable incorporating AWG28 wires  
• UL2651(standard cable)  
• UL20012 (folding cable)  
• UL20028 (color-code cable)  
Mating Combinations for XG4 and XG5  
Sockets  
Plugs  
XG4C  
Box-type  
Plugs  
XG4M  
MIL Connectors  
XG4T  
XG4E  
XG8W  
Original  
Plugs  
XG5M  
XG4A  
XG4A  
IDC Plugs with  
Long Locks  
XG4S  
Sockets for  
Discrete  
Wires  
2-tier Plugs MIL Plugs  
with Long  
Mates  
with  
Strain Reliefs  
Locks  
Strain Reliefs  
XG5N  
Discrete  
Wire  
Crimping  
Sockets  
XG4M  
MIL Sockets  
Plugs  
XG4C  
Box-type  
Plugs  
XG4A  
MIL Plugs with  
Short Locks  
XG4E  
XG8W  
Original  
Plugs  
IDC Plugs with  
Short Locks  
XG4S  
Mates  
with  
Strain Reliefs  
Sockets  
Plugs  
XG4C  
Box-type  
Plugs  
XG4M-U  
XG5N-U  
Discrete  
Wire  
Crimping  
Lock Levers  
MIL Sockets  
and Strain  
Relief with  
Locks  
Mates  
with  
2
Flat Cable Connectors XG4  
XG4M-U MIL Connectors with Socket Locks  
Dimensions  
(Unit: mm)  
XG4U  
Mating Diagrams for XG4M  
Strain Reliefs with Locks  
XG4U + XG4M + XG4C (with straight terminals)  
XG4U  
9.5  
5.6  
A
B
20.2  
3.3  
1
(Locked)  
XG4C  
6.7  
XG4M  
(16.8)  
XG4U + XG4M + XG4C (with right-angle terminals)  
10.1  
XG4U  
XG4U  
3
20.2  
9.3  
9.5  
5.6  
XG4M  
XG4C  
C
3.3  
1
XG4C  
7.4  
9.1  
(Unlocked)  
XG4M  
(16.5)  
Dimensions  
No. of  
contacts  
Dimensions (mm)  
C
3
A
B
D
E
XG4M-@@30 (one polarity guide)  
XG4M-@@31 (all others)  
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
26.8  
13.2  
26.2  
31.2  
33.8  
38.9  
46.5  
51.6  
56.6  
64.3  
77.0  
89.7  
94.7  
17.3  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
Open-end cover  
31.8  
34.4  
39.5  
47.1  
52.2  
57.2  
64.9  
77.6  
90.3  
95.3  
18.2  
20.8  
25.9  
33.5  
38.6  
43.6  
51.3  
64.0  
76.7  
81.7  
22.3  
24.9  
30.0  
37.6  
42.7  
47.7  
55.4  
68.1  
80.8  
85.8  
10.6  
6.6  
3
Triangular mark  
Polarizing Key slot (2) Polarity guide Polarizing Key slot (1)  
(not on models with  
less than 14 contacts)  
D
E
2.54  
3.8  
2.54  
6.1  
Ordering Information  
No. of  
contacts  
No. of polarity Socket and Strain Relief Sets (See note 1.) Socket with Open-end Cover (See note 2.) Strain Relief with Locks  
guides  
10  
0
1
1
1
1
1
1
1
1
1
XG4M-1031-U  
XG4M-1030-U  
XG4M-1430-U  
XG4M-1630-U  
XG4M-2030-U  
XG4M-2630-U  
XG4M-3030-U  
XG4M-3430-U  
XG4M-4030-U  
XG4M-5030-U  
XG4M-1031  
XG4M-1030  
XG4M-1430  
XG4M-1630  
XG4M-2030  
XG4M-2630  
XG4M-3030  
XG4M-3430  
XG4M-4030  
XG4M-5030  
XG4M-5031  
XG4M-6030  
XG4M-6031  
XG4M-6430  
XG4M-6431  
XG4U-1004  
14  
16  
20  
26  
30  
34  
40  
50  
XG4U-1404  
XG4U-1604  
XG4U-2004  
XG4U-2604  
XG4U-3004  
XG4U-3404  
XG4U-4004  
XG4U-5004  
2 (See note 3.) XG4M-5031-U  
XG4M-6030-U  
2 (See note 3.) XG4M-6031-U  
XG4M-6430-U  
2 (See note 3.) XG4M-6431-U  
60  
64  
1
XG4U-6004  
XG4U-6404  
1
Note: 1. With open-end cover.  
2. Strain Relief sold separately.  
3. Polarity guide pitch is 22.86 mm.  
Flat Cable Connectors XG4  
3
XG4M MIL Sockets  
Dimensions  
XG4M-@@30 (one polarizing guide)  
XG4M-@@31 (all others)  
(Unit: mm)  
Strain relief  
Open-end cover  
Dimensions  
Triangular mark  
Polarizing Key slot (2) Polarity guide  
(Not on models with  
less than 14 contacts.)  
Polarizing Key slot (1)  
No. of  
Dimensions (mm)  
contacts  
A
B
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
17.3  
22.3  
24.9  
30.0  
37.6  
42.7  
47.7  
55.4  
68.1  
80.8  
85.8  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
XG4T-@@04  
Strain Relief  
XG4M-@@30-T (XG4M-@@30 + XG4T-@@04)  
XG4M-@@31-T (XG4M-@@31 + XG4T-@@04)  
MIL Socket and Strain Relief Sets  
Ordering Information  
No. of  
No. of polarity Socket and Strain Relief Set (See note 1.)  
Socket with Open-end Cover (See note 2.) Strain Relief for the XG4M  
contacts  
guides  
10  
0
1
1
1
1
1
1
1
1
1
XG4M-1031-T  
XG4M-1030-T  
XG4M-1430-T  
XG4M-1630-T  
XG4M-2030-T  
XG4M-2630-T  
XG4M-3030-T  
XG4M-3430-T  
XG4M-4030-T  
XG4M-5030-T  
XG4M-1031  
XG4M-1030  
XG4M-1430  
XG4M-1630  
XG4M-2030  
XG4M-2630  
XG4M-3030  
XG4M-3430  
XG4M-4030  
XG4M-5030  
XG4M-5031  
XG4M-6030  
XG4M-6031  
XG4M-6430  
XG4M-6431  
XG4T-1004  
14  
16  
20  
26  
30  
34  
40  
50  
XG4T-1404  
XG4T-1604  
XG4T-2004  
XG4T-2604  
XG4T-3004  
XG4T-3404  
XG4T-4004  
XG4T-5004  
2 (See note 3.) XG4M-5031-T  
XG4M-6030-T  
2 (See note 3.) XG4M-6031-T  
XG4M-6430-T  
2 (See note 3.) XG4M-6431-T  
60  
64  
1
XG4T-6004  
XG4T-6404  
1
Note: 1. With open-end cover.  
2. Strain Relief sold separately.  
3. Polarity guide pitch is 22.86 mm  
4
Flat Cable Connectors XG4  
XG4A MIL Plugs with Long Locks (MIL Standards)  
Dimensions  
XG4A-@@31/-@@71 (With straight DIP terminals)  
XG4A-@@34/-@@74 (With right-angle DIP terminals)  
(Unit: mm)  
Straight DIP terminals  
Right-angle DIP terminals  
0.635 × 0.635  
0.635 × 0.635  
Straight DIP terminals  
Right-angle DIP terminals  
Two, 2.6 dia.  
(M3 tapping screw hole)  
Two, 2.65 dia.  
Triangular  
mark  
Polarizing Key slot  
(not on models with  
less than 14 contacts)  
Polarity slot  
Polarizing Key slot  
Mounting view (bottom view)  
Right-angle terminals  
Dimensions  
+0.1  
0
0.8  
dia. (DIP terminals)  
No. of  
contacts  
Dimensions (mm)  
A
B
C
D
E
F
46.4  
51.5  
54.1  
59.1  
66.8  
71.8  
76.9  
84.5  
97.2  
109.9  
115.0  
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
32.0  
37.1  
17.5  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
21.8  
27.9  
22.6  
25.2  
30.2  
37.9  
42.9  
48.0  
55.6  
68.3  
81.0  
86.1  
26.9  
29.5  
34.5  
42.2  
47.2  
52.3  
59.9  
72.6  
85.3  
90.4  
33.0  
35.6  
40.6  
48.3  
53.3  
58.4  
66.0  
78.7  
91.4  
96.5  
Two, 2.8 dia.  
(M2.6)  
Two, 3.2 dia.  
(M3 tapping  
screw hole)  
39.6  
44.7  
52.3  
57.4  
62.5  
70.1  
82.8  
95.5  
100.6  
Straight terminals  
dia. (DIP terminals)  
+0.1  
0
0.8  
Two, 3.2 dia.  
(M3 tapping  
screw hole)  
Note: See page 16 for details on the availability (10-contact Connectors)  
and pitch (with 50, 60, or 64-contact Connectors) of polarity slots.  
Flat Cable Connectors XG4  
5
Ordering Information  
Use in Combination with Strain-relief Sockets.  
Plugs with straight DIP terminals  
Plugs with right-angle DIP terminals  
No. of  
contacts  
No. of  
polarizing  
slots  
10  
0
1
1
1
1
1
1
1
1
1
XG4A-1071  
XG4A-1031  
XG4A-1431  
XG4A-1631  
XG4A-2031  
XG4A-2631  
XG4A-3031  
XG4A-3431  
XG4A-4031  
XG4A-5031  
XG4A-1074  
XG4A-1034  
XG4A-1434  
XG4A-1634  
XG4A-2034  
XG4A-2634  
XG4A-3034  
XG4A-3434  
XG4A-4034  
XG4A-5034  
XG4A-5074  
XG4A-6034  
XG4A-6074  
XG4A-6434  
XG4A-6474  
14  
16  
20  
26  
30  
34  
40  
50  
2 (See note.) XG4A-5071  
XG4A-6031  
2 (See note.) XG4A-6071  
XG4A-6431  
2 (See note.) XG4A-6471  
Note: Polarizing slot pitch is 22.86 mm.  
60  
64  
1
1
6
Flat Cable Connectors XG4  
XG4A MIL Plugs with Short Locks  
Dimensions  
XG4A-@@32/-@@72 (With straight DIP terminals)  
XG4A-@@35/-@@75 (With right-angle DIP terminals)  
(Unit: mm)  
Straight DIP terminals  
Right-angle DIP terminals  
0.635 × 0.635  
0.635 × 0.635  
Straight DIP terminals  
Right-angle DIP terminals  
Two, 2.6 dia.  
(M3 tapping screw hole)  
Two, 2.65 dia.  
Triangular  
mark  
Polarizing Key slot  
(not on models with  
less than 14 contacts)  
Polarity slot  
Polarizing Key slot  
Mounting holes (bottom view)  
Right-angle terminals  
Dimensions  
+0.1  
0
0.8  
dia. (DIP terminals)  
No. of  
contacts  
Dimensions (mm)  
A
B
C
D
E
27.9  
33.0  
35.6  
40.6  
48.3  
53.3  
58.4  
66.0  
78.7  
91.4  
96.5  
F
40.4  
45.5  
48.0  
53.1  
60.7  
65.8  
70.9  
78.5  
91.2  
103.9  
109.0  
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
32.0  
37.1  
17.5  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
21.8  
22.6  
25.2  
30.2  
37.9  
42.9  
48.0  
55.6  
68.3  
81.0  
86.1  
26.9  
29.5  
34.5  
42.2  
47.2  
52.3  
59.9  
72.6  
85.3  
90.4  
39.6  
44.7  
52.3  
57.4  
62.5  
70.1  
82.8  
95.5  
100.6  
Two, 2.8 dia.  
(M2.6)  
Two, 3.2 dia.  
(M3 tapping  
screw hole)  
Straight terminals  
+0.1  
0
0.8  
dia. (DIP terminals)  
Two, 3.2 dia.  
(M3 tapping  
screw hole)  
Note: See page 16 for details on the availability (10-contact Connectors)  
and pitch (with 50, 60, or 64-contact Connectors) of polarity slots.  
Flat Cable Connectors XG4  
7
Ordering Information  
Use in combination with sockets without strain-relief.  
Plugs with straight DIP terminals  
Plugs with right-angle DIP terminals  
No. of  
contacts  
No. of  
polarizing  
slots  
10  
0
1
1
1
1
1
1
1
1
1
XG4A-1072  
XG4A-1032  
XG4A-1432  
XG4A-1632  
XG4A-2032  
XG4A-2632  
XG4A-3032  
XG4A-3432  
XG4A-4032  
XG4A-5032  
XG4A-1075  
XG4A-1035  
XG4A-1435  
XG4A-1635  
XG4A-2035  
XG4A-2635  
XG4A-3035  
XG4A-3435  
XG4A-4035  
XG4A-5035  
XG4A-5075  
XG4A-6035  
XG4A-6075  
XG4A-6435  
XG4A-6475  
14  
16  
20  
26  
30  
34  
40  
50  
2 (See note.) XG4A-5072  
XG4A-6032  
2 (See note.) XG4A-6072  
XG4A-6432  
2 (See note.) XG4A-6472  
Note: Polarizing slot pitch is 22.86 mm.  
60  
64  
1
1
8
Flat Cable Connectors XG4  
XG4A MIL Plugs without Lock Levers (Lock Levers  
mounted later)  
Dimensions  
XG4A-@@33/-@@73 (With straight DIP terminals)  
XG4A-@@36/-@@76 (With right-angle DIP terminals)  
(Unit: mm)  
Straight DIP terminals  
Right-angle DIP terminals  
0.635 × 0.635  
0.635 × 0.635  
Straight DIP terminals  
Right-angle DIP terminals  
Two, 2.6 dia.  
(M3 tapping screw hole)  
Two, 2.65 dia.  
Triangular mark  
Polarizing Key slot  
Polarity slot  
Polarizing Key slot  
(not on models with  
less than 14 contacts)  
Mounting holes (bottom view)  
Dimensions  
Right-angle terminals  
+0.1  
0
0.8  
dia. (DIP terminals)  
No. of  
contacts  
Dimensions (mm)  
A
B
C
D
E
27.9  
33.0  
35.6  
40.6  
48.3  
53.3  
58.4  
66.0  
78.7  
91.4  
96.5  
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
32.0  
37.1  
17.5  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
21.8  
22.6  
25.2  
30.2  
37.9  
42.9  
48.0  
55.6  
68.3  
81.0  
86.1  
26.9  
29.5  
34.5  
42.2  
47.2  
52.3  
59.9  
72.6  
85.3  
90.4  
39.6  
44.7  
52.3  
57.4  
62.5  
70.1  
82.8  
95.5  
100.6  
C
D
0.12  
0.15  
Two, 2.8 dia.  
(M2.6)  
Two, 3.2 dia.  
(M3 tapping  
screw hole)  
Straight terminals  
dia. (DIP terminals)  
+0.1  
0
0.8  
Two, 3.2 dia.  
(M3 tapping  
screw hole)  
Note: See page 16 for details on the availability (10-contact Connectors)  
and pitch (with 50, 60, or 64-contact Connectors) of polarizing slots.  
Flat Cable Connectors XG4  
9
Ordering Information  
Plugs with straight DIP terminals  
Plugs right-angle DIP terminals  
No. of  
No. of  
polarizing  
slots  
contacts  
10  
0
1
1
1
1
1
1
1
1
1
XG4A-1073  
XG4A-1033  
XG4A-1433  
XG4A-1633  
XG4A-2033  
XG4A-2633  
XG4A-3033  
XG4A-3433  
XG4A-4033  
XG4A-5033  
XG4A-1076  
XG4A-1036  
XG4A-1436  
XG4A-1636  
XG4A-2036  
XG4A-2636  
XG4A-3036  
XG4A-3436  
XG4A-4036  
XG4A-5036  
XG4A-5076  
XG4A-6036  
XG4A-6076  
XG4A-6436  
XG4A-6476  
14  
16  
20  
26  
30  
34  
40  
50  
2 (See note.) XG4A-5073  
XG4A-6033  
2 (See note.) XG4A-6073  
XG4A-6433  
2 (See note.) XG4A-6473  
60  
64  
1
1
Note: Polarity slot pitch is 22.86 mm.  
Lock Levers  
This series of Connectors allows you to attach Lock Levers on  
Attachment after Soldering  
Right-angle Terminal Plugs after automated soldering is completed.  
Long Levers interfere with automated mounting.  
Lock Levers can be easily mounted simply by manually pushing  
them in.  
Long Levers are in the way when boards are packed.  
These problems are resolved using Connectors with Long Levers  
that can be attached after soldering is completed.  
XG4Z-0010  
XG4Z-0011  
Long Lock Lever  
Short Lock Lever  
Type  
Model  
Long Lock Levers  
Short Lock Levers  
XG4Z-0010  
XG4Z-0011  
Note: The left and right Lock Levers are identical. One pair is needed  
for each Plug.  
10  
Flat Cable Connectors XG4  
XG4A 2-tier Plugs with Long Lock  
Dimensions  
(Unit: mm)  
XG4A-@@39-A/-@@79-A  
(With long locks and right-  
angle DIP terminals)  
0.635 × 0.635  
Two, 2.65 dia.  
Stopper (For connecting top and bottom connectors)  
Dimensions  
Two, 2.65 dia.  
No. of  
Dimensions (mm)  
Triangular  
mark  
contacts  
Polarity slot  
Polarizing Key slot  
(not on the XG4A-  
1039-A)  
A
B
C
D
E
Polarizing Key slot  
(not on models with  
less than 14 contacts)  
10 × 2  
14 × 2  
16 × 2  
20 × 2  
26 × 2  
30 × 2  
34 × 2  
40 × 2  
50 × 2  
60 × 2  
64 × 2  
32.0 17.5 10.16 21.8 46.4  
37.1 22.6 15.24 26.9 51.5  
39.6 25.2 17.78 29.5 54.1  
44.7 30.2 22.86 34.5 59.1  
52.3 37.9 30.48 42.2 66.8  
57.4 42.9 35.56 47.2 71.8  
62.5 48.0 40.64 52.3 76.9  
70.1 55.6 48.26 59.9 84.9  
82.8 68.3 60.96 72.6 97.2  
95.5 81.0 73.66 85.3 109.9  
100.6 86.1 78.74 90.4 115.0  
Mounting holes (bottom view)  
+0.1  
0
0.8  
dia.  
Two, 2.8 dia.  
2.54 0.05  
2.54 0.05  
2.54 0.05  
2.54 0.05  
0.12  
C
D
0.15  
Note: Polarizing slot pitch is 22.86 mm for 50-, 60-,  
and 64-contact Connectors.  
Ordering Information  
Model  
Model  
No. of  
No. of  
polarizing  
slots  
No. of  
contacts  
No. of  
polarity slots  
contacts  
10 × 2  
0
1
1
1
1
1
1
1
XG4A-1079-A  
XG4A-1039-A  
XG4A-1439-A  
XG4A-1639-A  
XG4A-2039-A  
XG4A-2639-A  
XG4A-3039-A  
XG4A-3439-A  
40 × 2  
50 × 2  
60 × 2  
64 × 2  
1
XG4A-4039-A  
14 × 2  
16 × 2  
20 × 2  
26 × 2  
30 × 2  
34 × 2  
1
XG4A-5039-A  
XG4A-5079-A  
XG4A-6039-A  
XG4A-6079-A  
XG4A-6439-A  
XG4A-6479-A  
2 (See note 2.)  
1
2 (See note 2.)  
1
2 (See note 2.)  
Note: 1. Set containing a stopper, mounting screw (assembled with  
washer) and nut.  
2. Polarizing slot pitch is 22.86 mm.  
Screw size: M2.6 x 20 mm  
Flat Cable Connectors XG4  
11  
Mounting Example  
2-tier Plug Features  
Recommended for high-density mounting.  
MIL-compliant cable ensures faster delivery times and lower cost  
than half-pitch board cable. The 2.54-mm pitch simplifies pattern-  
ing.  
Cable Number and  
Applicable Sockets  
Contact Position  
Model  
No. of contacts No. of polarity slots  
XG4M for flat cable  
(See note 1.)  
XG5M-N for  
discrete wire  
Cable and Corresponding Contact Number  
(See note 2.)  
XG5M-103@-N  
XG5M-103@-N  
XG5M-143@-N  
XG5M-163@-N  
XG5M-203@-N  
XG5M-263@-N  
XG5M-303@-N  
XG5M-343@-N  
XG5M-403@-N  
XG5M-503@-N  
The contact numbers are not marked on the Con-  
nector. Use the triangular mark as a guide when  
wiring and designing circuit boards.  
10 × 2  
0
XG4A-1079-A XG4M-1031  
XG4A-1039-A XG4M-1030  
XG4A-1439-A XG4M-1430  
XG4A-1639-A XG4M-1630  
XG4A-2039-A XG4M-2030  
XG4A-2639-A XG4M-2630  
XG4A-3039-A XG4M-3030  
XG4A-3439-A XG4M-3430  
XG4A-4039-A XG4M-4030  
XG4A-5039-A XG4M-5030  
XG4A-5079-A XG4M-5031  
XG4A-6039-A XG4M-6030  
XG4A-6079-A XG4M-6031  
XG4A-6439-A XG4M-6430  
XG4A-6479-A XG4M-6431  
1
For the cable number, count starting from the cable  
mark side as shown below.  
14 × 2  
16 × 2  
20 × 2  
26 × 2  
30 × 2  
34 × 2  
40 × 2  
50 × 2  
1
1
Socket (mating side)  
1
1
Triangular mark  
XG4M  
1
1
1
1
2 (See note 3.)  
Cable mark  
Cable number  
60 × 2  
64 × 2  
1
XG5M-603@-N  
XG5M-643@-N  
2 (See note 3.)  
1
Right-angle terminals (terminal side)  
2 (See note 3.)  
XG4A  
Triangular mark (back)  
Note: 1. Use with the supplied Strain Relief.  
2. Use with the supplied Semi-cover. Hood Cover cannot be used.  
3. Polarity slot pitch is 22.86 mm.  
Lower connector  
Upper connector  
Precautions  
Soldering  
• Automated Soldering Conditions (Jet Flow)  
Correct Use  
Mounting  
1. Soldering temperature: 250 ±5°C  
2. Continuous soldering time: Within 5 ± 1 s  
Be sure to anchor the board with screws before mounting.  
Note that a Polarizing Key cannot be mounted on the lower Plug.  
Lock Lever Operation  
When you operate the lock lever, do not force it past the movable  
range.  
The connector may be damaged.  
Do not use any type of tool to operate the lock lever. Operate it only  
with your hand.  
Connecting the Socket  
Before connecting the XG4M with Strain Relief, remove as much  
slack from the cable as possible. Insert as shown below.  
Attach the Semi-cover before connecting the XG5M-N. It is not pos-  
sible to use the Hood Cover.  
The connector may be damaged.  
Always release the lock mechanism before you disconnect the con-  
nector from the connected socket.  
The connector may be damaged.  
12  
Flat Cable Connectors XG4  
XG4E IDC Plugs  
Dimensions  
(Unit: mm)  
XG4E-@@31/-@@71  
(With long locks)  
(Long locks)  
(Short locks)  
XG4E-@@32/-@@72  
(With short locks)  
0.635 × 0.635  
0.635 × 0.635  
Open-end cover  
Strain Relief  
Two, 2.6 dia.  
(M3 tapping screw hole)  
Two, 2.65 dia.  
Triangular  
mark  
Polarizing Key slot  
(Not on models with  
less than 14 contacts.)  
Polarity slot  
Polarizing Key slot  
XG4S-@@04  
Strain Relief  
Dimensions  
No. of  
contacts  
Dimensions (mm)  
A
B
C
D
E
F
G
Long  
Lock  
Short  
Lock  
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
32.0  
17.5  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
21.8  
27.9  
33.0  
35.6  
40.6  
48.3  
53.3  
58.4  
66.0  
78.7  
91.4  
96.5  
46.4  
40.4  
45.5  
48.0  
53.1  
60.7  
65.8  
70.9  
78.5  
91.2  
103.9  
109.0  
16.9  
37.1  
39.6  
44.7  
52.3  
57.4  
62.5  
70.1  
82.8  
95.5  
100.6  
22.6  
25.2  
30.2  
37.9  
42.9  
48.0  
55.6  
68.3  
81.0  
86.1  
26.9  
29.5  
34.5  
42.2  
47.2  
52.3  
59.9  
72.6  
85.3  
90.4  
51.5  
54.1  
59.1  
66.8  
71.8  
76.9  
84.5  
97.2  
109.9  
115.0  
22.0  
24.6  
29.6  
38.0  
42.3  
47.4  
55.0  
67.7  
80.4  
85.5  
Note: See the following page for details on the availability (10-contact Connectors) and pitch  
(with 50, 60, or 64-contact Connectors) of polarity slots.  
Flat Cable Connectors XG4  
13  
Ordering Information  
IDC Plugs  
Use Long-lock Plugs together with Strain-relief Sockets, and use Short-lock Plugs together with Non-strain-relief Sockets.  
Long-lock Plugs with Open-end Covers  
(See note 1.)  
Short-lock Plugs with Open-end Covers Strain Reliefs for XG4E  
(See note 1.)  
No. of  
contacts  
No. of  
polarizing  
slots  
10  
0
1
1
1
1
1
1
1
1
1
XG4E-1071  
XG4E-1031  
XG4E-1431  
XG4E-1631  
XG4E-2031  
XG4E-2631  
XG4E-3031  
XG4E-3431  
XG4E-4031  
XG4E-5031  
XG4E-1072  
XG4E-1032  
XG4E-1432  
XG4E-1632  
XG4E-2032  
XG4E-2632  
XG4E-3032  
XG4E-3432  
XG4E-4032  
XG4E-5032  
XG4E-5072  
XG4E-6032  
XG4E-6072  
XG4E-6432  
XG4E-6472  
XG4S-1004  
14  
16  
20  
26  
30  
34  
40  
50  
XG4S-1404  
XG4S-1604  
XG4S-2004  
XG4S-2604  
XG4S-3004  
XG4S-3404  
XG4S-4004  
XG4S-5004  
2 (See note 2.) XG4E-5071  
XG4E-6031  
2 (See note 2.) XG4E-6071  
XG4E-6431  
2 (See note 2.) XG4E-6471  
60  
64  
1
XG4S-6004  
XG4S-6404  
1
Note: 1. Strain Relief sold separately.  
2. Polarity slot pitch is 22.86 mm.  
Cable Number and Contact Position  
Socket (mated side)  
Right-angle Terminal Plug (terminal side)  
XG4A XG4C  
Cable and Corresponding  
Contact Number  
Triangular mark  
The contact numbers are not marked on  
the Connector. Use the triangular mark as  
a guide when wiring and designing circuit  
boards.  
Triangular mark  
(back)  
For the cable number, count starting from  
the cable mark side as shown on the right.  
Cable mark  
Cable No.  
Plug (XG4E)  
Straight Terminal Plug (terminal side)  
Triangular mark  
Triangular mark  
Cable mark  
Cable No.  
14  
Flat Cable Connectors XG4  
XG4C Box-type Plugs  
Dimensions  
(Unit: mm)  
XG4C-@@31/-@@71  
(With straight DIP terminals)  
Polarizing Key slot  
(Not on models with  
less than 14 contacts.)  
Triangular mark  
Polarity slot  
Polarizing Key slot  
Right-angle DIP terminals  
Straight DIP terminals  
Dimensions  
No. of  
contacts  
XG4C-@@34/-@@74  
(With right-angle DIP terminals)  
Dimensions (mm)  
(Straight DIP terminals)  
(Right-angle DIP terminals)  
A
20.0  
25.1  
27.6  
32.7  
40.3  
45.4  
50.5  
58.1  
70.8  
83.5  
88.6  
B
17.5  
22.6  
25.2  
30.2  
37.9  
42.9  
48.0  
55.6  
68.3  
81.0  
86.1  
C
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
Mounting holes (bottom view)  
Straight DIP terminals  
+0.1  
0
0.8  
dia.  
Right-angle DIP terminals  
+0.1  
0.8  
dia.  
0
Note: See the following page for details on  
the availability (10-contact Connec-  
tors) and pitch (with 50, 60, or 64-con-  
tact Connectors) of polarity slots.  
C
0.12  
Ordering Information  
Plugs with straight DIP terminals  
Plugs with right-angle DIP terminals  
No. of  
No. of  
polarizing  
slots  
contacts  
10  
0
1
1
1
1
1
1
1
1
1
XG4C-1071  
XG4C-1031  
XG4C-1431  
XG4C-1631  
XG4C-2031  
XG4C-2631  
XG4C-3031  
XG4C-3431  
XG4C-4031  
XG4C-5031  
XG4C-5071  
XG4C-6031  
XG4C-6071  
XG4C-6431  
XG4C-6471  
XG4C-1074  
XG4C-1034  
XG4C-1434  
XG4C-1634  
XG4C-2034  
XG4C-2634  
XG4C-3034  
XG4C-3434  
XG4C-4034  
XG4C-5034  
XG4C-5074  
XG4C-6034  
XG4C-6074  
XG4C-6434  
XG4C-6474  
14  
16  
20  
26  
30  
34  
40  
50  
2 (See note 1.)  
60  
64  
1
2 (See note 1.)  
1
2 (See note 1.)  
Note: 1. Polarizing slot pitch is 22.86 mm.  
2. The Box-type Plug can be locked using Lock Lever II (sold separately). (See XG4Z-0002 on page 19.)  
Flat Cable Connectors XG4  
15  
Mating Diagrams for XG4M  
XG4T + XG4M + XG4A  
XG4U + XG4M + XG4C  
(With straight terminals)  
XG4U  
XG4T + XG4M + XG4C + Lock Lever  
XG4T XG4M  
10.9  
XG4T XG4M  
20.2  
19.0  
27  
23.5  
XG4C  
XG4A  
XG4Z-0002  
Lock Lever  
XG4C  
XG4U + XG4M + XG4XCG4M  
(With right-angle terminals)  
XG4T + XG4M + XG8B (Original Plug) + Lock Lever  
XG4T + XG4M + XG4E  
XG4T  
XG4M  
XG4U  
XG4U  
9
XG4T XG4M  
XG4M  
XG4C  
20.2  
9.3  
28.1  
24.7  
18.8  
XG4C  
XG8B  
XG5Z-0002  
Lock Lever  
XG4M  
XG4E  
Polarity Slot and Polarizing Key Slot Number and Position  
Classification  
No. of contacts  
14 contacts  
10 contacts  
16 to 40 contacts  
50 to 64 contacts  
XG4M-1630 to XG4M-6430  
Polarizing Key slot  
XG4M-1031  
XG4M-1030  
XG4M-1430  
XG4M  
MIL Sockets  
---  
XG4M-5031, XG4M-6031,  
XG4M-6431  
Polarizing guide  
XG4A-163@ to XG4A-643@  
Polarizing  
Key slot  
XG4A-107@  
XG4E-107@  
XG4A-103@  
XG4E-103@  
XG4A-143@  
XG4E-143@  
XG4A  
XG4E-163@ to XG4E-643@  
MIL Plugs  
XG4E  
---  
XG4A-507@, XG4A-607@,  
XG4A-647@  
IDC Plugs  
Polarizing slot  
XG4E-507@, XG4E-607@,  
XG4E-647@  
XG4C-163@ to XG4C-643@  
Polarizing slot  
XG4C-107@  
XG4C-103@  
XG4C-143@  
XG4C  
Box-type Plugs  
---  
XG4C-507@, XG4C-607@,  
XG4C-647@  
Polarizing slot  
No. of polarizing  
guides (Polarizing  
Slots)  
0
1
1
0
1
1
1
2
1
2 (H = 22.86 mm)  
No. of Polarizing  
Key slot (Polarizing  
Key Slots)  
2
16  
Flat Cable Connectors XG4  
XG4H Board-to-Board Sockets  
Dimensions  
(Unit: mm)  
XG4H-@@31/-@@71  
(With straight DIP terminals)  
XG4H-3431-1  
XG4H-4031-1  
(With straight DIP terminals)  
*Sockets with model numbers end-  
ing in -1 are available only with 34  
or 40 contacts (provide kinked ter-  
minals and standoff to prevent the  
Sockets from falling over).  
Mounting holes (bottom view)  
0.8+0.1dia.  
0
0.05  
2.54  
6.1  
6.1  
2.54  
3.8  
Polarizing Key slot  
(Not on models with  
less than 14 contacts.)  
Triangular  
3.8  
2.54  
Polarizing Key slot  
(Not on models with less than 10  
0.05  
0.12  
2.54  
B
Polarizing Key slot  
Polarizing guide Triangular  
Polarity guide  
3
contacts.)  
7.1  
3
7.1  
mark  
A
mark  
6.2  
7.2  
6.6  
7.2  
0.6  
3.1  
Dimensions  
3.1  
B
A
2.54  
B
A
2.54  
No. of  
contacts  
A
B
XG4H-4034  
(With right-angle DIP terminals)  
10  
14  
16  
20  
26  
30  
34  
40  
50  
60  
64  
17.3  
22.3  
10.16  
15.24  
17.78  
22.86  
30.48  
35.56  
40.64  
48.26  
60.96  
73.66  
78.74  
50.8  
48.26  
24.9  
30.0  
37.6  
42.7  
47.7  
55.4  
68.1  
80.8  
85.8  
1.27  
1.27  
Mounting holes (bottom view)  
2.54  
6.24  
7.87 0.05  
2.92  
Mating end  
40, 0.9 dia.  
2
0.15  
8.4  
7.87  
2.54 0.08  
0.3 0.38  
2.54  
1.85  
0.7  
Ordering Information  
Sockets with straight DIP terminals  
Sockets with right-angle DIP terminals  
No. of  
No. of  
polarizing  
slots  
No. of  
contacts  
contacts  
10  
14  
16  
20  
26  
30  
34  
40  
50  
1
1
1
1
1
1
1
1
1
XG4H-1031  
XG4H-1431  
XG4H-1631  
XG4H-2031  
XG4H-2631  
XG4H-3031  
XG4H-3431-1  
XG4H-4031-1  
XG4H-5031  
40  
XG4H-4034  
2 (See note.) XG4H-5071  
XG4H-6031  
2 (See note.) XG4H-6071  
XG4H-6431  
2 (See note.) XG4H-6471  
Note: Polarizing guide pitch is 22.86 mm.  
60  
64  
1
1
Flat Cable Connectors XG4  
17  
Mating Diagrams for XG4H  
Plug  
XG8W Original Plugs  
XG4C Box-type Plugs  
Socket  
XG4H-@@31/-@@71  
(With straight DIP termi-  
nals)  
4.4  
2.54  
3.1  
2.54  
XG8W  
XG4H  
2.54  
11.8  
2.54  
6.5  
7.2  
XG4C  
XG4H  
XG4C  
XG8W  
XG4H  
12.9  
10.1  
9.7  
XG4H  
2.54  
Stacking  
2.54  
Stacking  
2.54  
Vertical  
Vertical  
XG4H-4034  
(With right-angle DIP ter-  
minals)  
---  
XG8W  
XG4H  
XG8W  
15.23  
XG4H  
15.23  
6.22  
0.02  
6.24  
6.22  
6.24  
Horizontal  
(forward direction)  
Horizontal  
(reverse direction)  
6.24  
XG4H  
10.9  
XG8W  
Vertical  
18  
Flat Cable Connectors XG4  
Tools and Accessories (Sold Separately)  
XG4Z-0004 Polarizing Key  
XG4Z-0005 Coding Pin  
XY2E-0002 Contact Cutting Driver  
Polarity guides and slots can be used by  
themselves to help prevent reverse inser-  
tion. Use the Polarizing Key as well for best  
results.  
(To prevent erroneous insertion)  
The Contact Cutting Driver is used to cut  
(twist off) a contact on the mating Plug  
when using an XG4Z-0005 Coding Pin.  
The Coding Pin is used to prevent confu-  
sion when many Connectors with the same  
number of contacts are lined up. It can also  
be used to prevent reverse insertion when  
using Connectors without a shroud like the  
XG8 Unshrouded Plug. The Coding Pin  
can also be used with XC5, and XC6 DIN  
Connectors as well as with XG5 Discrete-  
wire IDC Connectors.  
How to use  
Twist  
How to use  
Insert the plug  
contact into the  
groove on the  
Driver, and twist  
off the contact  
from the base.  
Insert  
Twist  
How to use  
Material: PBT resin  
(UL94 V-0)/white  
Twist  
Insert  
Material: PBT resin  
(UL94 V-0)/white  
Model  
XG4Z-0004  
XG4Z-0005  
XY2E-0002  
Polarizing Key  
Twist  
Polarizing Key slot  
Note: 1. A contact with a Coding Pin in-  
serted cannot be used.  
Note: Each XG4Z-0004 has 4 Polarizing  
2. Each XG4Z-0005 has 4 Polarizing  
Keys.  
Keys.  
Lock Lever II for XG4C Plugs  
Lock Lever for XG8B and XG8W Plugs (With Right-angle  
Terminals)  
XG4Z-0002  
XG5Z-0002  
Use to lock XG4C Box-type Plugs.  
Use to lock Unshrouded Plugs (for XG8B and XG8W Plugs with  
right-angle terminals).  
Material: Polyamide resin  
Material: Polyamide resin  
(UL94 V-2)/natural  
(UL94 V-2)/natural  
Lock Lever  
Tab  
XG4M  
Model  
XG4M  
XG4C  
Insert the tab on the Lock  
Lever into the guide hole.  
XG5Z-0002  
XG4Z-0002  
Polarity guide hole  
XG8B  
Precautions  
• Soldering  
Solder-mount the XG4A with the lock levers  
fully closed or fully open.  
Solder-mounting the XG4A with the lock  
lever half-open may cause play in lock lever  
due to thermal deformation of the housing.  
• Storage  
Correct Use  
• Automated Soldering Conditions (Jet  
Flow)  
If the lock levers of the XG4A or XG4E con-  
nector are left at an intermediate position  
for a long time, they may get to feel loose in  
operation due to deterioration of the plastic  
part. When the lock levers are not used,  
store the plug with the lock levers fully  
closed or fully open.  
1. Soldering temperature: 250 5°C  
2. Continuous soldering time: Within 5 1 s  
Flat Cable Connectors XG4  
19  
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. G039-E1-03  
0816(0412)(O)  

相关型号:

XG4A-3433

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-3434

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-3435

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-3436

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-3439-A

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-4031

Industry Standard Circuit Board Connectors Conform to MIL Standards

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-4032

Flat Cable Connectors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-4033

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-4034

Flat Cable Connectors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-4035

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-4036

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XG4A-4039-A

Board Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON