XM3A-3721 [OMRON]
The D-sub Connector are Ideal for Office Automation Interfacing;型号: | XM3A-3721 |
厂家: | OMRON ELECTRONICS LLC |
描述: | The D-sub Connector are Ideal for Office Automation Interfacing |
文件: | 总14页 (文件大小:3230K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
D-sub Connectors
XM3/XM2S
The D-sub Connector are Ideal for Office
Automation Interfacing
• Shielded against EMI.
• Multi-hole, ferrite-core Connectors (XM3B-F) offers space-sav-
ing design and superior noise protection at high frequency.
• Rugged, compact, metallized plastic hood (XM2S) provides
excellent noise protection.
• Conforms to UL standards. (No. E103202)
(XM2S hoods and other models not included.)
• Available with many kinds of standard Anchors and grounding fixtures.
• RoHS Compliant.
Connectors and Hoods
Model
Type
XM3B
XM3B-F
Sockets with Right-angle
DIP Terminals
Sockets with Right-angle
DIP Terminals and ferrite core
Appearance
Model
Type
XM3C
XM3F
XM3A
XM3D
Plugs with Right-angle
DIP Terminals
Sockets with Straight
DIP Terminals
Plugs with Solder Cup
Terminals
Sockets with Solder Cup
Terminals
Appearance
Model
XM2S
XM2S-E
Type Straight Cable Connection
Metallized Plastic
Right Angle Cable Connection
Straight Cable Connection,
Metallized Plastic for 9 and 25 terminal models with ESD Production for 9 terminal models
Appearance
D-sub Connectors XM3/XM2S
1
■ Ratings and Characteristics
XM3A, XM3B, XM3B-F,
XM3C (except 37 terminal models),
XM3D, XM3F
XM2S, XM2S-E
(Hoods)
XM3C - 37 terminal models
Rated current
5 A
3 A
Rated voltage
300 VAC
Contact resistance
Insulation resistance
Dielectric strength
Total insertion force
Removal force
15 mΩ max. (at 20 mV, 100 mA max.)
1,000 MΩ min. (at 500 VDC)
1,000 VAC for 1 min. (leakage current: 1 mA max.)
Number of terminals x 3.33 N max.
0.29 N min. (for gauge diameter of 0.99 mm)
200 times
- - -
Insertion Durability
Ambient operating
temperature
−55°C to 105°C (with no icing)
−25°C to 85°C
Shield performance
Mounted in panel: 25 dB min. (30 to 900 MHz)
Mounted on board: 20 dB min. (30 to 900 MHz)
- - -
■ Materials and Finish
Connectors
XM3B
XM3B-F
XM3C
XM3F
XM3A
XM3D
Housing
Contacts
Fiber-glass reinforced PBT resin (UL94V-0)/black
Fiber-glass reinforced PBT resin
(UL94V-0)/Milky white
Phosphor Bronze / Nickel base, gold plated (0.4 μm)
Bronze / Nickel Phosphor
base, goldplated Bronze / Nickel
Mating End
Terminals
(0.4
μm)
base, goldplated
(0.4 m)
Phosphor Bronze / Nickel base, Phosphor Bronze / Nickel base, Bronze / Nickel Phosphor
μ
tin plated (2 μm)
tin plated (3 μm)
base, tin plated Bronze / Nickel
(3 μm)
base, tin plated
(3 μm)
Shell
Steel.
Nickel plated
Hoods
XM2S
XM2S-E
Straight Connecting Cable
Right-angle Connecting Cable Straight Connecting Cable with
ESD Protection
Housing
ABS resin / nickel plated
ABS resin
Cable clamp
Steel / nickel plated
- - -
Lock screw (Driver type)
Lock screw (Jackscrew)
Steel / nickel plated
- - -
Brass / nickel plated (See note)
Brass / nickel plated
Fiber-glass reinforced polyamide
(UL94V-0)/black
Note: Jackscrews (thumbscrews) for the straight, non-ESD version of the XM2S hood are sold separately. See “Accessories” section of this datasheet.
■ Applicable Wires
The applicable wires for solder cup terminals are AWG 22 to 28 (solid or stranded).
2
D-sub Connectors XM3/XM2S
XM3B Sockets with Right-angle DIP Terminals
Dimensions
(unit:mm)
XM3B-@@22-@@@
Two, 3.1 dia.
25-contact model shown above.
(With anchor 2, Lock Pin, Grounding Fixtures)
Mounting holes (t = 1.6 mm, bottom view)
No. of
contacts
A
B
C
D
E
F
Two, 3.2 0.1 dia.
9
30.8
24.99
33.32
47.04
63.50
16.30
24.65
38.35
54.80
10.96
19.18
33.12
49.68
8.22
2.74
15
25
37
39.1
53.0
69.3
16.44
30.36
46.92
2.74
2.76
2.76
1
0.1 dia.
Note: XM3B Sockets were manufactured in accordance with JIS X 5101. Terminal pitches are a mixed arrangement
of 2.77 and 2.74 mm contacts on 25 and 37 contact models as specified in the JIS standard. A pitch of 2.76 mm
is recommended for the mounting holes because of the more advanced numerical control available today.
This is sufficient to avoid any problems.
Ordering Information
Anchor 2
Anchor 2
Appearance
Lock Pin Grounding
Fixture
Tap Hole Grounding
Fixture
Accessories
XM2Z-0011 Anchor 2
(M2.6 × 0.45 metric screws)
XM2Z-0013 Anchor 2
XM2Z-0011 Anchor 2 (M2.6 × 0.45 XM2Z-0013 Anchor 2 (#4-40 UNC
metric screws) inch screws)
(#4-40 UNC inch screws)
No. of
contacts
XM2Z-0061
Tap Hole Grounding Fixtures
XM2Z-0062
Lock Pin Grounding Fixtures
9
XM3B-0922-111
XM3B-1522-111
XM3B-2522-111
XM3B-3722-111
XM3B-0922-131
XM3B-0922-112
XM3B-1522-112
XM3B-2522-112
XM3B-3722-112
XM3B-0922-132
15
25
37
XM3B-1522-131
XM3B-1522-132
XM3B-2522-131
XM3B-2522-132
XM3B-3722-131
XM3B-3722-132
Appearance
Tap Hole Grounding
Fixture
Lock Pin Grounding
Fixture
Accessories
No anchors
XM2Z-0061
Tap Hole Grounding Fixtures
No. of
contacts
---
XM2Z-0062
Lock Pin Grounding Fixtures
9
XM3B-0922
XM3B-1522
XM3B-2522
XM3B-3722
XM3B-0922-501
XM3B-0922-502
XM3B-1522-502
XM3B-2522-502
XM3B-3722-502
15
25
37
XM3B-1522-501
XM3B-2522-501
XM3B-3722-501
Note: 1. Use the XM3B-@@22 (No anchors or grounding fixtures) in combination with suitable Anchors and Grounding Fixtures.
2. Two M3 x 0.5 Tap Hole Grounding Fixtures and an M3 x 0.5 Lock Pin Grounding Fixture for the Anchor Side are provided.
D-sub Connectors XM3/XM2S
3
XM3B-F Sockets with Right-angle DIP Terminals and Ferrite Cores
Dimensions
(unit:mm)
XM3B-@@22-501F
25-contact model shown above.
Two, M3
(With Tap Hole Grounding Fixtures)
Two, M3
Tap Hole Grounding
Fixture
Ferrite core
Mounting holes (t = 1.6 mm, bottom view)
No. of
contacts
A
B
C
D
E
F
G
9
30.8
24.99
33.32
47.04
63.50
16.30
24.65
38.35
54.80
10.96
19.18
33.12
49.68
8.22
2.74
14.3
15
25
37
39.1
53.0
69.3
16.44
30.36
46.92
2.74
2.76
2.76
22.0
36.5
53.3
Two, 3.2 0.1 dia.
1
0.1 dia.
Note: XM3B Sockets were manufactured in accordance with JIS X 5101. Terminal pitches are a mixed arrangement
of 2.77 and 2.74 mm contacts on 25 and 37 contact models as specified in the JIS standard. A pitch of 2.76 mm
is recommended for the mounting holes because of the more advanced numerical control available today.
This is sufficient to avoid any problems.
Ordering Information
Appearance
Tap Hole Grounding Fixture
XM2Z-0061
Tap Hole Grounding Fixtures
Accessories
No. of
contacts
9
XM3B-0922-501F
15
25
37
XM3B-1522-501F
XM3B-2522-501F
XM3B-3722-501F
4
D-sub Connectors XM3/XM2S
XM3C Plugs with Right-angle DIP Terminals
Dimensions
A
(unit:mm)
XM3C-@@22-@@@
B
C
D
E
F
G
3.2
N
N-1
6.25
25-contact model shown above.
(No Anchor or Grounding Fixtures)
12.5
8.35
2
1
Two, 3.1 dia.
0.3
5.9
9.6
Mounting holes (t = 1.6 mm, bottom view)
3.6
0.1
0.1
0.1
B
D
E
18.5
2.84
0.1
F
3.3
3.0
B
No. of
contacts
A
B
C
D
E
F
G
15.5
3.0
9.9
N-1
N
9
30.8
24.99
33.32
47.04
63.50
16.91
25.25
38.96
55.42
10.96
19.18
33.12
49.68
8.22
2.74
1.37
15
25
37
39.1
53.0
69.3
16.44
30.36
46.92
2.74
2.76
2.76
1.37
1.38
1.38
1
2
1
0.1 dia.
0.1
2.84
Two, 3.2 0.1 dia.
0.1
F
Note: XM3C Sockets were manufactured in accordance with JIS X 5101. Terminal pitches are a mixed arrangement of 2.77 and 2.74 mm con-
tacts on 25 and 37 contact models as specified in the JIS standard. A pitch of 2.76 mm is recommended for the mounting holes because
of the more advanced numerical control available today. This is sufficient to avoid any problems.
Ordering Information
Tap Hole Grounding Fixture
Lock Pin Grounding Fixture
Appearance
Anchor 2
Anchor 2
XM2Z-0011 Anchor 2
(M2.6 × 0.45 metric screws)
Accessories
No. of
contacts
Tap Hole Grounding Fixtures
Lock Pin Grounding Fixtures
9
XM3C-0922-111
XM3C-1522-111
XM3C-2522-111
XM3C-3722-111
XM3C-0922-112
XM3C-1522-112
XM3C-2522-112
XM3C-3722-112
15
25
37
Tap Hole Grounding Fixture
Lock Pin Grounding Fixture
Appearance
Accessories
No anchors
No. of
---
Tap Hole Grounding Fixtures
Lock Pin Grounding Fixtures
XM3C-0922-502
contacts
9
XM3C-0922
XM3C-1522
XM3C-2522
XM3C-3722
XM3C-0922-501
15
25
37
XM3C-1522-501
XM3C-2522-501
XM3C-3722-501
XM3C-1522-502
XM3C-2522-502
XM3C-3722-502
Note: 1. Use the XM3C-@@22 (No anchors or grounding fixtures) in combination with suitable Anchors and Grounding Fixtures.
2. Two M3 x 0.5 Tap Hole Grounding Fixtures and an M3 x 0.5 Lock Pin Grounding Fixture for the Anchor Side are provided.
3. XM3C-@@22-@3@ versions with Inch Screws are also available.
D-sub Connectors XM3/XM2S
5
XM3F Sockets with Straight DIP Terminals
Dimensions
(unit:mm)
XM3F-@@20
XM3F-@@20-112
25-contact model shown on the left.
(No anchors or grounding fixtures)
25-contact model shown on the left.
(With Anchors and Grounding Fixtures)
A
B
A
B
Two, 3.1 dia.
M2.6×0.45
N-1
N
N-1
N
6
12.5 7.9
12.5 7.9
1
2
1
2
H
H
5
0.3
6.1
0.3
6.8
7
6.1
2.8
7
0.5
Anchor
Lock Pin
Grounding
Fixture
0.7
0.5
0.7
0.5
3.2
3.2
2.84
2.84
C
C
F
F
1
2
1
2
9
9
N-1
N
N-1
N
D
D
E
E
G
G
Mounting holes (t = 1.6 mm, bottom view)
0.1
B
0.1
E
No. of
contacts
A
B
C
D
E
F
G
H
Two, 3.2 0.1 dia.
0.1
(D)
F
9
30.7
39.0
52.9
69.2
24.99
33.32
47.04
63.50
10.98
19.20
33.12
49.68
1.37
8.22
2.74
19.00
27.12
41.04
57.60
16.33
24.66
38.38
54.84
N
N-1
15
25
37
1.37
1.38
1.38
16.44
30.36
46.92
2.74
2.76
2.76
2
1
2.84
0.1
F
1
0.1 dia.
0.1
C
Ordering Information
Appearance
No. of
contacts
No anchors or Grounding Fixtures
Anchors and Lock Pin Grounding Fixtures
9
XM3F-0920
XM3F-1520
XM3F-2520
XM3F-3720
XM3F-0920-112
XM3F-1520-112
XM3F-2520-112
XM3F-3720-112
15
25
37
D-sub Connectors XM3/XM2S
XM3A Plugs with Solder-cup Terminals
XM3D Sockets with Solder-cup Terminals
Dimensions
(unit:mm)
A
XM3A-@@21
B
C
D
E
Two, 3.1 dia.
1
2
12.4 8.35
N-1
N
G
F
Note: 25-contact model shown above.
5.9
8.25
1.5
1.48 dia.
No. of
contacts
A
B
C
D
E
F
G
9
30.7
39.0
52.9
69.2
24.99
33.32
47.04
63.50
16.91
25.25
38.96
55.42
10.96
19.18
33.12
49.68
8.22
2.74
1.37
15
25
37
16.44
30.36
46.92
2.74
2.76
2.76
1.37
1.38
1.38
XM3D-@@21
A
B
C
D
E
Two, 3.1 dia.
2
1
12.4 7.9
N
N-1
G
F
Note: 25-contact model shown above.
6.1
8.45
1.5
No. of
contacts
A
B
C
D
E
F
G
1.53 dia.
9
30.7
39.0
52.9
69.2
24.99
33.32
47.04
63.50
16.33
24.66
38.38
54.84
10.96
19.18
33.12
49.68
8.22
2.74
2.74
2.76
2.76
1.37
1.37
1.38
1.38
15
25
37
16.44
30.36
46.92
Ordering Information
Plugs
Sockets
Appearance
No. of
contacts
9
XM3A-0921
XM3A-1521
XM3A-2521
XM3A-3721
XM3D-0921
XM3D-1521
XM3D-2521
XM3D-3721
15
25
37
D-sub Connectors XM3/XM2S
7
XM2S / XM2S-E Straight and Right Angle Hoods
Dimensions
(unit:mm)
9-contact Hood
with Straight Connecting Cable
9-contact Hood
15, 25 and 37-Contact Hoods
XM2S-091@
Max. applicable diameter: 9 dia.
Max. applicable cable diameter: F dia.
Dot (screw head)
15, 25 and 37-contact Hood
with Straight Connecting Cable
XM2S-@@1@
Lock screw
M2.6 × 0.45
M3 × 0.5
Lock screw
M2.6 × 0.45
M3 × 0.5
#4-40 UNC
#4-40 UNC
No. of
contacts
A
B
C
D
E
F
Dot Shape
15
40.5
33.32
47.04
63.50
26.5
40
19
29
42
30
38
50
10
11
13
No dot
1 dot
2 dots
25
37
54.0
70.5
57
(unit:mm)
9-contact Hood with
Right-angle Connecting Cable
16
XM2S-092@
5 dia.
48
5.5
25.2
Groove
Max. applicable
cable diameter: 9 dia.
18.2
24.99
Lock screw
M2.6 × 0.45
45
25-contact Hood with
Right-angle Connecting Cable
XM2S-252@
15
Max. applicable diameter: 11 dia. (See note.)
Note: The maximum applicable cable diameter for
the 25-contact right-angle hood is 9 dia if
the cable clamp supplied is mounted facing
the rear.
5 dia.
23
39
6
41
Do not use a cable bushing in this case.
Lock screw
Groove Shape
M2.6 × 0.45
M3 × 0.5
No Groove
1 Groove
2 Grooves
Groove
#4-40 UNC
40
47.04
54
8
D-sub Connectors XM3/XM2S
Max. applicable cable diameter: 9 dia.
(unit:mm)
9-contact Hood
with Straight Connecting Cable
and ESD Protection
XM2S-0911-E
15
11
13
40.8
18.2
24.99
32.2
M2.6 × 0.45
Note: Jackscrews (thumbscrews) for the straight, non-ESD version of the XM2S hood are sold separately. See “Accessories” section of this datasheet.
Ordering Information
Straight hoods
Lock screw
M2.6 x 0.45 metric screws
(No dot)
M3 x 0.5 metric screws
(1 dot)
#4-40 UNC inch screws
(2 dots)
Applicable
Anchors
Anchor 1
Anchor 2
Anchor 3
XM2Z-0001
XM2Z-0011
XM2Z-0021
XM2Z-0002
XM2Z-0012
XM2Z-0022
XM2Z-0003
XM2Z-0013
XM2Z-0023
No. of contacts
9
XM2S-0911
XM2S-0912
XM2S-0913
15
25
37
XM2S-1511
XM2S-2511
XM2S-3711
XM2S-1512
XM2S-2512
XM2S-3712
XM2S-1513
XM2S-2513
XM2S-3713
*Jackscrews(thumbscrews) for the straight hoods without ESD protection are sold separately. See XM2Z-007@ (Anchor 5) in the Accessories section of this datasheet.
Right-angle hoods
Lock screw
M2.6 x 0.45 metric screws
(No groove)
M3 x 0.5 metric screws
(1 groove)
#4-40 UNC inch screws
(2 groove)
Applicable
Anchor 1
XM2Z-0001
XM2Z-0002
XM2Z-0003
Anchors (See Note 3)
Anchor 2
XM2Z-0011
XM2Z-0021
XM2Z-0012
XM2Z-0022
XM2Z-0013
XM2Z-0023
No. of contacts
Anchor 3
9
XM2S-0921
XM2S-2521
XM2S-0922
XM2S-2522
XM2S-0923
XM2S-2523
25
*Jackscrews (thumbscrews) for the right-angle hoods are standard, supplied with the hoods.
Straight hood with ESD Protection
Lock screw
M2.6 x 0.45 metric screws
(No groove)
Applicable
Anchors
Anchor 1
Anchor 2
Anchor 3
XM2Z-0001
XM2Z-0011
XM2Z-0021
No. of contacts
9
XM2S-0911-E
*Overmolded Jackscrews (thumbscrews) for the straight hoods with ESD protection are standard, supplied with the hoods.
Note: 1. The cable bushing, cable clamp, shielded tape and assorted screws are supplied with all hoods
2. Lock screws are attached to the Hood. Select D-sub Connectors with Anchors or Grounding Fixtures that fit the lock screw of the hood.
3. Anchor 1 cannot be used with the 9 Contact Right-angle Hoods.
D-sub Connectors XM3/XM2S
9
Accessories for XM3 (Sold Separately)
■ XM2T Dust Covers for Sockets
With Retaining Ring
XM2T-@@01
Dust Cover holding ring
0.9 dia.
No. of
contacts
A
B
C
D
Model
9
17.7
16.3
8
68
77
XM2T-0901
15
25
37
26.1
39.8
56.2
24.7
38.4
54.8
10
15
18
XM2T-1501
XM2T-2501
XM2T-3701
120
135
Without Retaining Ring
XM2T-@@01-0
XM2T Rating and Material
Operating Temperature −25°C to 85°C
Polyamide resin
No. of
contacts
A
B
C
Model
Material
9
17.7
16.3
8
XM2T-0901-0
XM2T-1501-0
XM2T-2501-0
XM2T-3701-0
15
25
37
26.1
39.8
56.2
24.7
38.4
54.8
10
15
18
■ XM2Z Anchors
Anchor 1 (Rectangular)
Anchor 2 (Hexagonal)
XM2Z-001@
Anchor 3 (Hexagonal)
XM2Z-002@
XM2Z-000@
Thread Type
Model
Thread Type
Model
Thread Type
Model
M2.6 x 0.45 metric screw XM2Z-0001
M3 x 0.5 metric screws XM2Z-0002
#4-40 UNC inch screws XM2Z-0003
M2.6 x 0.45 metric screw XM2Z-0011
M3 x 0.5 metric screws XM2Z-0012
#4-40 UNC inch screws XM2Z-0013
M2.6 x 0.45 metric screw XM2Z-0021
M3 x 0.5 metric screws XM2Z-0022
#4-40 UNC inch screws XM2Z-0023
Materials and Finish
Zinc die-cast/nickel plated
Materials and Finish
Iron/nickel plated
Materials and Finish
Iron/nickel plated
5
5
Part A
Female screw
(Mates with lock screw)
M3 × 0.5
Female screw
M3 × 0.5
(mates with lock screw)
Female screw
(Mates with lock
screw and
M2.6 × 0.45
M3 × 0.5
#4-40 UNC
mounting screw)
Note: When using a Dust Cover, secure the
Note: Anchor 3 is used for panel mounting
connectors. Applicable cable panel
thickness is 0.6 to 1.3 mm.
holding ring at part A.
Note: 2 anchors are necessary per connector. Anchors are not packaged in pairs.
10
D-sub Connectors XM3/XM2S
Anchor 5
XM2Z-007@
Thread Type (A)
Number of
Grooves
Groove Shape
Model
Screw A
2.35 dia.
M2.6 x 0.45 metric screw None
XM2Z-0071
M3 x 0.5 metric screws
#4-40 UNC inch screws
1
2
XM2Z-0072
XM2Z-0073
4 dia.
Materials and Finish
Brass/nickel plated
Note: Anchor 5 is for use only with the Straight Connecting XM2S hoods, to provide a Thumbscrew feature.
2 anchors are necessary per connector. Anchors are not packaged in pairs.
■ XM2Z Grounding Fixtures for XM3B
Tap Hole Grounding Fixtures
Lock Pin Grounding Fixtures
XM2Z-006@
Material and Finish
Phosphor bronze/nickel plated
Applicable through-hole diameter: 3.2 dia.
XM2Z-006@
Material and Finish
Steel/nickel plated
Fixed side tap hole
(M3 × 0.5) or through
hole (3.5 dia.)
Fixed side tap hole
(M3 × 0.5) or through
hole (4.0 dia.)
PCB side
M3 × 0.5
Tap Hole
Grounding Fixtures
Lock Pin
Grounding Fixtures
Thread Type
Fixed-side tap holes
XM2Z-0061
XM2Z-0062
XM2Z-0064
Fixed-side through holes XM2Z-0063
Note: 2 Grounding Fixtures are necessary per connector. Grounding Fixtures are not packaged in pairs.
Assembly Information
■ Anchors and Grounding Fixtures
Anchor 2 and 3
Anchor 1
Without Anchor
Grounding
Fixture (fixed-
side tap hole)
Commercial
hexagonal
nut (M3)
Connector
Anchor 1
Connector
Connector
Grounding Fixture
(fixed-side tap hole)
Commercial
screws (M3)
Commercial
screws
Anchor
2 or 3
Note: Always use a screw without an Anchor.
A grounding Fixture (fixed-side tap) can
be used in place of the hexagonal nut.
Note: Use Grounding Fixtures
Note: 1. Use Grounding Fixtures
XM2Z-0061 or XM2Z-0062.
XM2Z-0063 or XM2Z-0064.
2. Use a 6-mm screw that mates with the male
screw on Anchor 1.
■ Combination of Hexagonal Anchors for each connector (in post installation)
Type
Model
Without Panel Insertion
With Panel Insertion
Commercially available nut
DIP L type socket
XM3B-@@22
XM2Z-001@
XM2Z-002@
Necessary
XM3B-@@22-501@
XM3B-@@22-502
XM3C-@@22
Not Necessary
DIP L type plug
XM2Z-001@
XM2Z-001@
XM2Z-002@
XM2Z-002@
Necessary
XM3C-@@22-501
XM3C-@@22-502
XM3F-@@20
Not Necessary
DIP straight socket
Necessary
D-sub Connectors XM3/XM2S
11
■ Combination Examples
Relaying Example
Hood
Anchor 1
Hood
(XM2S-@@1@)
Lock screw M2.6 × 0.45
(See note.)
Anchor 1
Note: Screw the lock screw of the Hood into the hole on Anchor 1.
Plug with Solder-cup Terminals
Sockets with Right-angle DIP
Terminals (With Anchor 2 and
Tap Hole Grounding Fixtures)
Sockets and Right-angle DIP
Terminals (With Anchor 2 and
Lock Pin Grounding Fixtures)
Sockets and Right-angle DIP
Terminals (no anchor or
grounding fixtures)
Sockets with Solder-cup Terminals
Anchor 2
(XM2Z-001@)
Anchor 3
(XM2Z-002@)
Anchor 1
(XM2Z-000@)
Panel
Panel
(t = 1.3 max.)
Panel
(t = 1.3 max.)
Panel
Commercial
M3 nut
Commercial
M3 nut
Commercial
nut
Connector
Commercial
screw
Anchor 3
Connector
Anchor 3
Anchor 1
Anchor 2
Connector
XM3D
Panel mounting procedure
Applicable anchors
Not secured to the panel
Secured to the panel
Anchor 2
Anchor 1
Anchor 3 or M3 screws
A min.
Two, 3.2
0.1 dia.
A min.
13 min.
6.4 min.
11.4 min.
Two, R3.2
11.4 min.
Panel
Four, R1
Four, R3.4
Four, R2.5
dimensions
A (mm)
A (mm)
34.1
A (mm) B (mm)
No. of contacts
No. of contacts
No. of contacts
9
31.0
39.4
53.3
69.6
9
9
24.99
33.32
47.04
63.50
20.5
28.8
42.5
59.1
15
25
37
15
25
37
42.4
56.1
72.6
15
25
37
Note: 1. 2 Anchors are required per connector. Anchors are not packaged in pairs
2. Applicable panel thickness is 1.3 mm max.
12
D-sub Connectors XM3/XM2S
Precautions
■ Correct Use
Grounding
Shielded Cable Preparation
Refer to the following diagram when soldering shielded cable to the connector
when using a hood.
To ground, create copper foil around the connector attachment hole on the
board, assemble the connector and grounding fixture, and dip in solder as
shown below.
No. of Contacts
L (mm)
25
Tap Hole Grounding Fixtures
9
Insert the connector into the PCB, tighten the screws, and then dip-solder the
connector terminals to the board.
15
25
37
35
40
45
Tap Hole Grounding Fixtures
PCB (t = 1.6 mm)
Braided shield
Cable bushing
Approx. 2.3
M3 screw
10 1 (Folded shield dimensions)
12 (Taped shield dimensions)
Lock Pin Grounding Fixtures
Insert the connector into the PCB and then simultaneously dip-solder the con-
nector terminals and lock pin to the board.
1. Fold the unravelled braided shield back over the cable bushing
2. Wrap tape around the folded shield.
Shield Effects
Lock Pin Grounding Fixtures
PCB (t = 1.6 mm)
When connecting the braided cable shield to a connector hood, use the cable
clamp to clamp all the braids at once through the shielded tape.
Mate the lock screw washer and spring washer outside the connector when
assembling the hood.
Clamp screws (2)
Cable bushing (1)
Shielded tape (1)
Cable clamp
Approx.
Lock screw
2.2 to 2.5
washers (2)
with spring
washer
Cover screw
hexagonal nut
(2)
Attaching the Dust Cover
To attach the cord to the connector, use Anchor 1 and secure it as shown
below.
Cord
XM3B
Keep the shell flange of the connector as far away from the metal panel as
possible to maximize the shield effect with a connector mounted to a panel.
Anchor 1
The ground wire for the connector will fall into the shell (external metal cover-
ing) with solder-cup terminals, so connect the ground wire to the panel or to
ground on the board.
To attach the cord to a panel, drill an M3 hole in the panel and secure the cord
to it with an M3 screw. If the cord is not required, cut it off. Use a commercially
available M3 screw.
Shell flange
Gap
Panel mounting holes
Panel
XM3A/XM3D Connector Insertion and Removal
Grasp the connector or the hood cover when inserting and removing the con-
nector. Never try to remove the connector by pulling the cable.
Tightening Clamp Screws
Use the following torques when tightening cable clamp to hood.
Soldering - Automated Soldering Conditions.
(Jet Flow) (XM3B, XM3C and XM3F)
1. Soldering temperature: 250 5°C
2. Continuous soldering time: Within 5 s
Terminal Screw Tightening Torque (N·m)
9
15
Contacts
25
37
Contacts
Contacts
Contacts
0.25
0.44
0.49
D-sub Connectors XM3/XM2S
13
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
01/13
Specifications subject to change without notice
Printed in USA
Cat. No. G057-E-1a
14
D-sub Connectors XM3/XM2S
相关型号:
XM3B-0922
D Subminiature Connector, 9 Contact(s), Female, Solder Terminal, Socket,Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0922-111
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0922-131
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0922-501
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0922-502
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0942-112L
D-sub ConnectorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0942-132L
D-sub ConnectorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0942-132LS
D Subminiature Connector, 9 Contact(s), Female, 0.108 inch Pitch, Solder Terminal, #4-40, ReceptacleWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-0942-502L
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-1522-111
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-1522-112
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
XM3B-1522-131
D Subminiature ConnectorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
©2020 ICPDF网 联系我们和版权申明