XM3B-2522 [OMRON]

D Subminiature Connector, 25 Contact(s), Female, Solder Terminal, Socket,;
XM3B-2522
型号: XM3B-2522
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

D Subminiature Connector, 25 Contact(s), Female, Solder Terminal, Socket,

连接器
文件: 总14页 (文件大小:3224K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
D-sub Connectors  
XM3/XM2S  
The D-sub Connector are Ideal for Office  
Automation Interfacing  
• Shielded against EMI.  
• Multi-hole, ferrite-core Connectors (XM3B-F) offers space-sav-  
ing design and superior noise protection at high frequency.  
• Rugged, compact, metallized plastic hood (XM2S) provides  
excellent noise protection.  
• Conforms to UL standards. (No. E103202)  
(XM2S hoods and other models not included.)  
• Available with many kinds of standard Anchors and grounding fixtures.  
• RoHS Compliant.  
Connectors and Hoods  
Model  
Type  
XM3B  
XM3B-F  
Sockets with Right-angle  
DIP Terminals  
Sockets with Right-angle  
DIP Terminals and ferrite core  
Appearance  
Model  
Type  
XM3C  
XM3F  
XM3A  
XM3D  
Plugs with Right-angle  
DIP Terminals  
Sockets with Straight  
DIP Terminals  
Plugs with Solder Cup  
Terminals  
Sockets with Solder Cup  
Terminals  
Appearance  
Model  
XM2S  
XM2S-E  
Type Straight Cable Connection  
Metallized Plastic  
Right Angle Cable Connection  
Straight Cable Connection,  
Metallized Plastic for 9 and 25 terminal models with ESD Production for 9 terminal models  
Appearance  
D-sub Connectors XM3/XM2S  
1
Ratings and Characteristics  
XM3A, XM3B, XM3B-F,  
XM3C (except 37 terminal models),  
XM3D, XM3F  
XM2S, XM2S-E  
(Hoods)  
XM3C - 37 terminal models  
Rated current  
5 A  
3 A  
Rated voltage  
300 VAC  
Contact resistance  
Insulation resistance  
Dielectric strength  
Total insertion force  
Removal force  
15 mΩ max. (at 20 mV, 100 mA max.)  
1,000 MΩ min. (at 500 VDC)  
1,000 VAC for 1 min. (leakage current: 1 mA max.)  
Number of terminals x 3.33 N max.  
0.29 N min. (for gauge diameter of 0.99 mm)  
200 times  
- - -  
Insertion Durability  
Ambient operating  
temperature  
55°C to 105°C (with no icing)  
25°C to 85°C  
Shield performance  
Mounted in panel: 25 dB min. (30 to 900 MHz)  
Mounted on board: 20 dB min. (30 to 900 MHz)  
- - -  
Materials and Finish  
Connectors  
XM3B  
XM3B-F  
XM3C  
XM3F  
XM3A  
XM3D  
Housing  
Contacts  
Fiber-glass reinforced PBT resin (UL94V-0)/black  
Fiber-glass reinforced PBT resin  
(UL94V-0)/Milky white  
Phosphor Bronze / Nickel base, gold plated (0.4 μm)  
Bronze / Nickel Phosphor  
base, goldplated Bronze / Nickel  
Mating End  
Terminals  
(0.4  
μm)  
base, goldplated  
(0.4 m)  
Phosphor Bronze / Nickel base, Phosphor Bronze / Nickel base, Bronze / Nickel Phosphor  
μ
tin plated (2 μm)  
tin plated (3 μm)  
base, tin plated Bronze / Nickel  
(3 μm)  
base, tin plated  
(3 μm)  
Shell  
Steel.  
Nickel plated  
Hoods  
XM2S  
XM2S-E  
Straight Connecting Cable  
Right-angle Connecting Cable Straight Connecting Cable with  
ESD Protection  
Housing  
ABS resin / nickel plated  
ABS resin  
Cable clamp  
Steel / nickel plated  
- - -  
Lock screw (Driver type)  
Lock screw (Jackscrew)  
Steel / nickel plated  
- - -  
Brass / nickel plated (See note)  
Brass / nickel plated  
Fiber-glass reinforced polyamide  
(UL94V-0)/black  
Note: Jackscrews (thumbscrews) for the straight, non-ESD version of the XM2S hood are sold separately. See “Accessories” section of this datasheet.  
Applicable Wires  
The applicable wires for solder cup terminals are AWG 22 to 28 (solid or stranded).  
2
D-sub Connectors XM3/XM2S  
XM3B Sockets with Right-angle DIP Terminals  
Dimensions  
(unit:mm)  
XM3B-@@22-@@@  
Two, 3.1 dia.  
25-contact model shown above.  
(With anchor 2, Lock Pin, Grounding Fixtures)  
Mounting holes (t = 1.6 mm, bottom view)  
No. of  
contacts  
A
B
C
D
E
F
Two, 3.2 0.1 dia.  
9
30.8  
24.99  
33.32  
47.04  
63.50  
16.30  
24.65  
38.35  
54.80  
10.96  
19.18  
33.12  
49.68  
8.22  
2.74  
15  
25  
37  
39.1  
53.0  
69.3  
16.44  
30.36  
46.92  
2.74  
2.76  
2.76  
1
0.1 dia.  
Note: XM3B Sockets were manufactured in accordance with JIS X 5101. Terminal pitches are a mixed arrangement  
of 2.77 and 2.74 mm contacts on 25 and 37 contact models as specified in the JIS standard. A pitch of 2.76 mm  
is recommended for the mounting holes because of the more advanced numerical control available today.  
This is sufficient to avoid any problems.  
Ordering Information  
Anchor 2  
Anchor 2  
Appearance  
Lock Pin Grounding  
Fixture  
Tap Hole Grounding  
Fixture  
Accessories  
XM2Z-0011 Anchor 2  
(M2.6 × 0.45 metric screws)  
XM2Z-0013 Anchor 2  
XM2Z-0011 Anchor 2 (M2.6 × 0.45 XM2Z-0013 Anchor 2 (#4-40 UNC  
metric screws) inch screws)  
(#4-40 UNC inch screws)  
No. of  
contacts  
XM2Z-0061  
Tap Hole Grounding Fixtures  
XM2Z-0062  
Lock Pin Grounding Fixtures  
9
XM3B-0922-111  
XM3B-1522-111  
XM3B-2522-111  
XM3B-3722-111  
XM3B-0922-131  
XM3B-0922-112  
XM3B-1522-112  
XM3B-2522-112  
XM3B-3722-112  
XM3B-0922-132  
15  
25  
37  
XM3B-1522-131  
XM3B-1522-132  
XM3B-2522-131  
XM3B-2522-132  
XM3B-3722-131  
XM3B-3722-132  
Appearance  
Tap Hole Grounding  
Fixture  
Lock Pin Grounding  
Fixture  
Accessories  
No anchors  
XM2Z-0061  
Tap Hole Grounding Fixtures  
No. of  
contacts  
---  
XM2Z-0062  
Lock Pin Grounding Fixtures  
9
XM3B-0922  
XM3B-1522  
XM3B-2522  
XM3B-3722  
XM3B-0922-501  
XM3B-0922-502  
XM3B-1522-502  
XM3B-2522-502  
XM3B-3722-502  
15  
25  
37  
XM3B-1522-501  
XM3B-2522-501  
XM3B-3722-501  
Note: 1. Use the XM3B-@@22 (No anchors or grounding fixtures) in combination with suitable Anchors and Grounding Fixtures.  
2. Two M3 x 0.5 Tap Hole Grounding Fixtures and an M3 x 0.5 Lock Pin Grounding Fixture for the Anchor Side are provided.  
D-sub Connectors XM3/XM2S  
3
XM3B-F Sockets with Right-angle DIP Terminals and Ferrite Cores  
Dimensions  
(unit:mm)  
XM3B-@@22-501F  
25-contact model shown above.  
Two, M3  
(With Tap Hole Grounding Fixtures)  
Two, M3  
Tap Hole Grounding  
Fixture  
Ferrite core  
Mounting holes (t = 1.6 mm, bottom view)  
No. of  
contacts  
A
B
C
D
E
F
G
9
30.8  
24.99  
33.32  
47.04  
63.50  
16.30  
24.65  
38.35  
54.80  
10.96  
19.18  
33.12  
49.68  
8.22  
2.74  
14.3  
15  
25  
37  
39.1  
53.0  
69.3  
16.44  
30.36  
46.92  
2.74  
2.76  
2.76  
22.0  
36.5  
53.3  
Two, 3.2 0.1 dia.  
1
0.1 dia.  
Note: XM3B Sockets were manufactured in accordance with JIS X 5101. Terminal pitches are a mixed arrangement  
of 2.77 and 2.74 mm contacts on 25 and 37 contact models as specified in the JIS standard. A pitch of 2.76 mm  
is recommended for the mounting holes because of the more advanced numerical control available today.  
This is sufficient to avoid any problems.  
Ordering Information  
Appearance  
Tap Hole Grounding Fixture  
XM2Z-0061  
Tap Hole Grounding Fixtures  
Accessories  
No. of  
contacts  
9
XM3B-0922-501F  
15  
25  
37  
XM3B-1522-501F  
XM3B-2522-501F  
XM3B-3722-501F  
4
D-sub Connectors XM3/XM2S  
XM3C Plugs with Right-angle DIP Terminals  
Dimensions  
A
(unit:mm)  
XM3C-@@22-@@@  
B
C
D
E
F
G
3.2  
N
N-1  
6.25  
25-contact model shown above.  
(No Anchor or Grounding Fixtures)  
12.5  
8.35  
2
1
Two, 3.1 dia.  
0.3  
5.9  
9.6  
Mounting holes (t = 1.6 mm, bottom view)  
3.6  
0.1  
0.1  
0.1  
B
D
E
18.5  
2.84  
0.1  
F
3.3  
3.0  
B
No. of  
contacts  
A
B
C
D
E
F
G
15.5  
3.0  
9.9  
N-1  
N
9
30.8  
24.99  
33.32  
47.04  
63.50  
16.91  
25.25  
38.96  
55.42  
10.96  
19.18  
33.12  
49.68  
8.22  
2.74  
1.37  
15  
25  
37  
39.1  
53.0  
69.3  
16.44  
30.36  
46.92  
2.74  
2.76  
2.76  
1.37  
1.38  
1.38  
1
2
1
0.1 dia.  
0.1  
2.84  
Two, 3.2 0.1 dia.  
0.1  
F
Note: XM3C Sockets were manufactured in accordance with JIS X 5101. Terminal pitches are a mixed arrangement of 2.77 and 2.74 mm con-  
tacts on 25 and 37 contact models as specified in the JIS standard. A pitch of 2.76 mm is recommended for the mounting holes because  
of the more advanced numerical control available today. This is sufficient to avoid any problems.  
Ordering Information  
Tap Hole Grounding Fixture  
Lock Pin Grounding Fixture  
Appearance  
Anchor 2  
Anchor 2  
XM2Z-0011 Anchor 2  
(M2.6 × 0.45 metric screws)  
Accessories  
No. of  
contacts  
Tap Hole Grounding Fixtures  
Lock Pin Grounding Fixtures  
9
XM3C-0922-111  
XM3C-1522-111  
XM3C-2522-111  
XM3C-3722-111  
XM3C-0922-112  
XM3C-1522-112  
XM3C-2522-112  
XM3C-3722-112  
15  
25  
37  
Tap Hole Grounding Fixture  
Lock Pin Grounding Fixture  
Appearance  
Accessories  
No anchors  
No. of  
---  
Tap Hole Grounding Fixtures  
Lock Pin Grounding Fixtures  
XM3C-0922-502  
contacts  
9
XM3C-0922  
XM3C-1522  
XM3C-2522  
XM3C-3722  
XM3C-0922-501  
15  
25  
37  
XM3C-1522-501  
XM3C-2522-501  
XM3C-3722-501  
XM3C-1522-502  
XM3C-2522-502  
XM3C-3722-502  
Note: 1. Use the XM3C-@@22 (No anchors or grounding fixtures) in combination with suitable Anchors and Grounding Fixtures.  
2. Two M3 x 0.5 Tap Hole Grounding Fixtures and an M3 x 0.5 Lock Pin Grounding Fixture for the Anchor Side are provided.  
3. XM3C-@@22-@3@ versions with Inch Screws are also available.  
D-sub Connectors XM3/XM2S  
5
XM3F Sockets with Straight DIP Terminals  
Dimensions  
(unit:mm)  
XM3F-@@20  
XM3F-@@20-112  
25-contact model shown on the left.  
(No anchors or grounding fixtures)  
25-contact model shown on the left.  
(With Anchors and Grounding Fixtures)  
A
B
A
B
Two, 3.1 dia.  
M2.6×0.45  
N-1  
N
N-1  
N
6
12.5 7.9  
12.5 7.9  
1
2
1
2
H
H
5
0.3  
6.1  
0.3  
6.8  
7
6.1  
2.8  
7
0.5  
Anchor  
Lock Pin  
Grounding  
Fixture  
0.7  
0.5  
0.7  
0.5  
3.2  
3.2  
2.84  
2.84  
C
C
F
F
1
2
1
2
9
9
N-1  
N
N-1  
N
D
D
E
E
G
G
Mounting holes (t = 1.6 mm, bottom view)  
0.1  
B
0.1  
E
No. of  
contacts  
A
B
C
D
E
F
G
H
Two, 3.2 0.1 dia.  
0.1  
(D)  
F
9
30.7  
39.0  
52.9  
69.2  
24.99  
33.32  
47.04  
63.50  
10.98  
19.20  
33.12  
49.68  
1.37  
8.22  
2.74  
19.00  
27.12  
41.04  
57.60  
16.33  
24.66  
38.38  
54.84  
N
N-1  
15  
25  
37  
1.37  
1.38  
1.38  
16.44  
30.36  
46.92  
2.74  
2.76  
2.76  
2
1
2.84  
0.1  
F
1
0.1 dia.  
0.1  
C
Ordering Information  
Appearance  
No. of  
contacts  
No anchors or Grounding Fixtures  
Anchors and Lock Pin Grounding Fixtures  
9
XM3F-0920  
XM3F-1520  
XM3F-2520  
XM3F-3720  
XM3F-0920-112  
XM3F-1520-112  
XM3F-2520-112  
XM3F-3720-112  
15  
25  
37  
D-sub Connectors XM3/XM2S  
XM3A Plugs with Solder-cup Terminals  
XM3D Sockets with Solder-cup Terminals  
Dimensions  
(unit:mm)  
A
XM3A-@@21  
B
C
D
E
Two, 3.1 dia.  
1
2
12.4 8.35  
N-1  
N
G
F
Note: 25-contact model shown above.  
5.9  
8.25  
1.5  
1.48 dia.  
No. of  
contacts  
A
B
C
D
E
F
G
9
30.7  
39.0  
52.9  
69.2  
24.99  
33.32  
47.04  
63.50  
16.91  
25.25  
38.96  
55.42  
10.96  
19.18  
33.12  
49.68  
8.22  
2.74  
1.37  
15  
25  
37  
16.44  
30.36  
46.92  
2.74  
2.76  
2.76  
1.37  
1.38  
1.38  
XM3D-@@21  
A
B
C
D
E
Two, 3.1 dia.  
2
1
12.4 7.9  
N
N-1  
G
F
Note: 25-contact model shown above.  
6.1  
8.45  
1.5  
No. of  
contacts  
A
B
C
D
E
F
G
1.53 dia.  
9
30.7  
39.0  
52.9  
69.2  
24.99  
33.32  
47.04  
63.50  
16.33  
24.66  
38.38  
54.84  
10.96  
19.18  
33.12  
49.68  
8.22  
2.74  
2.74  
2.76  
2.76  
1.37  
1.37  
1.38  
1.38  
15  
25  
37  
16.44  
30.36  
46.92  
Ordering Information  
Plugs  
Sockets  
Appearance  
No. of  
contacts  
9
XM3A-0921  
XM3A-1521  
XM3A-2521  
XM3A-3721  
XM3D-0921  
XM3D-1521  
XM3D-2521  
XM3D-3721  
15  
25  
37  
D-sub Connectors XM3/XM2S  
7
XM2S / XM2S-E Straight and Right Angle Hoods  
Dimensions  
(unit:mm)  
9-contact Hood  
with Straight Connecting Cable  
9-contact Hood  
15, 25 and 37-Contact Hoods  
XM2S-091@  
Max. applicable diameter: 9 dia.  
Max. applicable cable diameter: F dia.  
Dot (screw head)  
15, 25 and 37-contact Hood  
with Straight Connecting Cable  
XM2S-@@1@  
Lock screw  
M2.6 × 0.45  
M3 × 0.5  
Lock screw  
M2.6 × 0.45  
M3 × 0.5  
#4-40 UNC  
#4-40 UNC  
No. of  
contacts  
A
B
C
D
E
F
Dot Shape  
15  
40.5  
33.32  
47.04  
63.50  
26.5  
40  
19  
29  
42  
30  
38  
50  
10  
11  
13  
No dot  
1 dot  
2 dots  
25  
37  
54.0  
70.5  
57  
(unit:mm)  
9-contact Hood with  
Right-angle Connecting Cable  
16  
XM2S-092@  
5 dia.  
48  
5.5  
25.2  
Groove  
Max. applicable  
cable diameter: 9 dia.  
18.2  
24.99  
Lock screw  
M2.6 × 0.45  
45  
25-contact Hood with  
Right-angle Connecting Cable  
XM2S-252@  
15  
Max. applicable diameter: 11 dia. (See note.)  
Note: The maximum applicable cable diameter for  
the 25-contact right-angle hood is 9 dia if  
the cable clamp supplied is mounted facing  
the rear.  
5 dia.  
23  
39  
6
41  
Do not use a cable bushing in this case.  
Lock screw  
Groove Shape  
M2.6 × 0.45  
M3 × 0.5  
No Groove  
1 Groove  
2 Grooves  
Groove  
#4-40 UNC  
40  
47.04  
54  
8
D-sub Connectors XM3/XM2S  
Max. applicable cable diameter: 9 dia.  
(unit:mm)  
9-contact Hood  
with Straight Connecting Cable  
and ESD Protection  
XM2S-0911-E  
15  
11  
13  
40.8  
18.2  
24.99  
32.2  
M2.6 × 0.45  
Note: Jackscrews (thumbscrews) for the straight, non-ESD version of the XM2S hood are sold separately. See “Accessories” section of this datasheet.  
Ordering Information  
Straight hoods  
Lock screw  
M2.6 x 0.45 metric screws  
(No dot)  
M3 x 0.5 metric screws  
(1 dot)  
#4-40 UNC inch screws  
(2 dots)  
Applicable  
Anchors  
Anchor 1  
Anchor 2  
Anchor 3  
XM2Z-0001  
XM2Z-0011  
XM2Z-0021  
XM2Z-0002  
XM2Z-0012  
XM2Z-0022  
XM2Z-0003  
XM2Z-0013  
XM2Z-0023  
No. of contacts  
9
XM2S-0911  
XM2S-0912  
XM2S-0913  
15  
25  
37  
XM2S-1511  
XM2S-2511  
XM2S-3711  
XM2S-1512  
XM2S-2512  
XM2S-3712  
XM2S-1513  
XM2S-2513  
XM2S-3713  
*Jackscrews(thumbscrews) for the straight hoods without ESD protection are sold separately. See XM2Z-007@ (Anchor 5) in the Accessories section of this datasheet.  
Right-angle hoods  
Lock screw  
M2.6 x 0.45 metric screws  
(No groove)  
M3 x 0.5 metric screws  
(1 groove)  
#4-40 UNC inch screws  
(2 groove)  
Applicable  
Anchor 1  
XM2Z-0001  
XM2Z-0002  
XM2Z-0003  
Anchors (See Note 3)  
Anchor 2  
XM2Z-0011  
XM2Z-0021  
XM2Z-0012  
XM2Z-0022  
XM2Z-0013  
XM2Z-0023  
No. of contacts  
Anchor 3  
9
XM2S-0921  
XM2S-2521  
XM2S-0922  
XM2S-2522  
XM2S-0923  
XM2S-2523  
25  
*Jackscrews (thumbscrews) for the right-angle hoods are standard, supplied with the hoods.  
Straight hood with ESD Protection  
Lock screw  
M2.6 x 0.45 metric screws  
(No groove)  
Applicable  
Anchors  
Anchor 1  
Anchor 2  
Anchor 3  
XM2Z-0001  
XM2Z-0011  
XM2Z-0021  
No. of contacts  
9
XM2S-0911-E  
*Overmolded Jackscrews (thumbscrews) for the straight hoods with ESD protection are standard, supplied with the hoods.  
Note: 1. The cable bushing, cable clamp, shielded tape and assorted screws are supplied with all hoods  
2. Lock screws are attached to the Hood. Select D-sub Connectors with Anchors or Grounding Fixtures that fit the lock screw of the hood.  
3. Anchor 1 cannot be used with the 9 Contact Right-angle Hoods.  
D-sub Connectors XM3/XM2S  
9
Accessories for XM3 (Sold Separately)  
XM2T Dust Covers for Sockets  
With Retaining Ring  
XM2T-@@01  
Dust Cover holding ring  
0.9 dia.  
No. of  
contacts  
A
B
C
D
Model  
9
17.7  
16.3  
8
68  
77  
XM2T-0901  
15  
25  
37  
26.1  
39.8  
56.2  
24.7  
38.4  
54.8  
10  
15  
18  
XM2T-1501  
XM2T-2501  
XM2T-3701  
120  
135  
Without Retaining Ring  
XM2T-@@01-0  
XM2T Rating and Material  
Operating Temperature 25°C to 85°C  
Polyamide resin  
No. of  
contacts  
A
B
C
Model  
Material  
9
17.7  
16.3  
8
XM2T-0901-0  
XM2T-1501-0  
XM2T-2501-0  
XM2T-3701-0  
15  
25  
37  
26.1  
39.8  
56.2  
24.7  
38.4  
54.8  
10  
15  
18  
XM2Z Anchors  
Anchor 1 (Rectangular)  
Anchor 2 (Hexagonal)  
XM2Z-001@  
Anchor 3 (Hexagonal)  
XM2Z-002@  
XM2Z-000@  
Thread Type  
Model  
Thread Type  
Model  
Thread Type  
Model  
M2.6 x 0.45 metric screw XM2Z-0001  
M3 x 0.5 metric screws XM2Z-0002  
#4-40 UNC inch screws XM2Z-0003  
M2.6 x 0.45 metric screw XM2Z-0011  
M3 x 0.5 metric screws XM2Z-0012  
#4-40 UNC inch screws XM2Z-0013  
M2.6 x 0.45 metric screw XM2Z-0021  
M3 x 0.5 metric screws XM2Z-0022  
#4-40 UNC inch screws XM2Z-0023  
Materials and Finish  
Zinc die-cast/nickel plated  
Materials and Finish  
Iron/nickel plated  
Materials and Finish  
Iron/nickel plated  
5
5
Part A  
Female screw  
(Mates with lock screw)  
M3 × 0.5  
Female screw  
M3 × 0.5  
(mates with lock screw)  
Female screw  
(Mates with lock  
screw and  
M2.6 × 0.45  
M3 × 0.5  
#4-40 UNC  
mounting screw)  
Note: When using a Dust Cover, secure the  
Note: Anchor 3 is used for panel mounting  
connectors. Applicable cable panel  
thickness is 0.6 to 1.3 mm.  
holding ring at part A.  
Note: 2 anchors are necessary per connector. Anchors are not packaged in pairs.  
10  
D-sub Connectors XM3/XM2S  
Anchor 5  
XM2Z-007@  
Thread Type (A)  
Number of  
Grooves  
Groove Shape  
Model  
Screw A  
2.35 dia.  
M2.6 x 0.45 metric screw None  
XM2Z-0071  
M3 x 0.5 metric screws  
#4-40 UNC inch screws  
1
2
XM2Z-0072  
XM2Z-0073  
4 dia.  
Materials and Finish  
Brass/nickel plated  
Note: Anchor 5 is for use only with the Straight Connecting XM2S hoods, to provide a Thumbscrew feature.  
2 anchors are necessary per connector. Anchors are not packaged in pairs.  
XM2Z Grounding Fixtures for XM3B  
Tap Hole Grounding Fixtures  
Lock Pin Grounding Fixtures  
XM2Z-006@  
Material and Finish  
Phosphor bronze/nickel plated  
Applicable through-hole diameter: 3.2 dia.  
XM2Z-006@  
Material and Finish  
Steel/nickel plated  
Fixed side tap hole  
(M3 × 0.5) or through  
hole (3.5 dia.)  
Fixed side tap hole  
(M3 × 0.5) or through  
hole (4.0 dia.)  
PCB side  
M3 × 0.5  
Tap Hole  
Grounding Fixtures  
Lock Pin  
Grounding Fixtures  
Thread Type  
Fixed-side tap holes  
XM2Z-0061  
XM2Z-0062  
XM2Z-0064  
Fixed-side through holes XM2Z-0063  
Note: 2 Grounding Fixtures are necessary per connector. Grounding Fixtures are not packaged in pairs.  
Assembly Information  
Anchors and Grounding Fixtures  
Anchor 2 and 3  
Anchor 1  
Without Anchor  
Grounding  
Fixture (fixed-  
side tap hole)  
Commercial  
hexagonal  
nut (M3)  
Connector  
Anchor 1  
Connector  
Connector  
Grounding Fixture  
(fixed-side tap hole)  
Commercial  
screws (M3)  
Commercial  
screws  
Anchor  
2 or 3  
Note: Always use a screw without an Anchor.  
A grounding Fixture (fixed-side tap) can  
be used in place of the hexagonal nut.  
Note: Use Grounding Fixtures  
Note: 1. Use Grounding Fixtures  
XM2Z-0061 or XM2Z-0062.  
XM2Z-0063 or XM2Z-0064.  
2. Use a 6-mm screw that mates with the male  
screw on Anchor 1.  
Combination of Hexagonal Anchors for each connector (in post installation)  
Type  
Model  
Without Panel Insertion  
With Panel Insertion  
Commercially available nut  
DIP L type socket  
XM3B-@@22  
XM2Z-001@  
XM2Z-002@  
Necessary  
XM3B-@@22-501@  
XM3B-@@22-502  
XM3C-@@22  
Not Necessary  
DIP L type plug  
XM2Z-001@  
XM2Z-001@  
XM2Z-002@  
XM2Z-002@  
Necessary  
XM3C-@@22-501  
XM3C-@@22-502  
XM3F-@@20  
Not Necessary  
DIP straight socket  
Necessary  
D-sub Connectors XM3/XM2S  
11  
Combination Examples  
Relaying Example  
Hood  
Anchor 1  
Hood  
(XM2S-@@1@)  
Lock screw M2.6 × 0.45  
(See note.)  
Anchor 1  
Note: Screw the lock screw of the Hood into the hole on Anchor 1.  
Plug with Solder-cup Terminals  
Sockets with Right-angle DIP  
Terminals (With Anchor 2 and  
Tap Hole Grounding Fixtures)  
Sockets and Right-angle DIP  
Terminals (With Anchor 2 and  
Lock Pin Grounding Fixtures)  
Sockets and Right-angle DIP  
Terminals (no anchor or  
grounding fixtures)  
Sockets with Solder-cup Terminals  
Anchor 2  
(XM2Z-001@)  
Anchor 3  
(XM2Z-002@)  
Anchor 1  
(XM2Z-000@)  
Panel  
Panel  
(t = 1.3 max.)  
Panel  
(t = 1.3 max.)  
Panel  
Commercial  
M3 nut  
Commercial  
M3 nut  
Commercial  
nut  
Connector  
Commercial  
screw  
Anchor 3  
Connector  
Anchor 3  
Anchor 1  
Anchor 2  
Connector  
XM3D  
Panel mounting procedure  
Applicable anchors  
Not secured to the panel  
Secured to the panel  
Anchor 2  
Anchor 1  
Anchor 3 or M3 screws  
A min.  
Two, 3.2  
0.1 dia.  
A min.  
13 min.  
6.4 min.  
11.4 min.  
Two, R3.2  
11.4 min.  
Panel  
Four, R1  
Four, R3.4  
Four, R2.5  
dimensions  
A (mm)  
A (mm)  
34.1  
A (mm) B (mm)  
No. of contacts  
No. of contacts  
No. of contacts  
9
31.0  
39.4  
53.3  
69.6  
9
9
24.99  
33.32  
47.04  
63.50  
20.5  
28.8  
42.5  
59.1  
15  
25  
37  
15  
25  
37  
42.4  
56.1  
72.6  
15  
25  
37  
Note: 1. 2 Anchors are required per connector. Anchors are not packaged in pairs  
2. Applicable panel thickness is 1.3 mm max.  
12  
D-sub Connectors XM3/XM2S  
Precautions  
Correct Use  
Grounding  
Shielded Cable Preparation  
Refer to the following diagram when soldering shielded cable to the connector  
when using a hood.  
To ground, create copper foil around the connector attachment hole on the  
board, assemble the connector and grounding fixture, and dip in solder as  
shown below.  
No. of Contacts  
L (mm)  
25  
Tap Hole Grounding Fixtures  
9
Insert the connector into the PCB, tighten the screws, and then dip-solder the  
connector terminals to the board.  
15  
25  
37  
35  
40  
45  
Tap Hole Grounding Fixtures  
PCB (t = 1.6 mm)  
Braided shield  
Cable bushing  
Approx. 2.3  
M3 screw  
10 1 (Folded shield dimensions)  
12 (Taped shield dimensions)  
Lock Pin Grounding Fixtures  
Insert the connector into the PCB and then simultaneously dip-solder the con-  
nector terminals and lock pin to the board.  
1. Fold the unravelled braided shield back over the cable bushing  
2. Wrap tape around the folded shield.  
Shield Effects  
Lock Pin Grounding Fixtures  
PCB (t = 1.6 mm)  
When connecting the braided cable shield to a connector hood, use the cable  
clamp to clamp all the braids at once through the shielded tape.  
Mate the lock screw washer and spring washer outside the connector when  
assembling the hood.  
Clamp screws (2)  
Cable bushing (1)  
Shielded tape (1)  
Cable clamp  
Approx.  
Lock screw  
2.2 to 2.5  
washers (2)  
with spring  
washer  
Cover screw  
hexagonal nut  
(2)  
Attaching the Dust Cover  
To attach the cord to the connector, use Anchor 1 and secure it as shown  
below.  
Cord  
XM3B  
Keep the shell flange of the connector as far away from the metal panel as  
possible to maximize the shield effect with a connector mounted to a panel.  
Anchor 1  
The ground wire for the connector will fall into the shell (external metal cover-  
ing) with solder-cup terminals, so connect the ground wire to the panel or to  
ground on the board.  
To attach the cord to a panel, drill an M3 hole in the panel and secure the cord  
to it with an M3 screw. If the cord is not required, cut it off. Use a commercially  
available M3 screw.  
Shell flange  
Gap  
Panel mounting holes  
Panel  
XM3A/XM3D Connector Insertion and Removal  
Grasp the connector or the hood cover when inserting and removing the con-  
nector. Never try to remove the connector by pulling the cable.  
Tightening Clamp Screws  
Use the following torques when tightening cable clamp to hood.  
Soldering - Automated Soldering Conditions.  
(Jet Flow) (XM3B, XM3C and XM3F)  
1. Soldering temperature: 250 5°C  
2. Continuous soldering time: Within 5 s  
Terminal Screw Tightening Torque (N·m)  
9
15  
Contacts  
25  
37  
Contacts  
Contacts  
Contacts  
0.25  
0.44  
0.49  
D-sub Connectors XM3/XM2S  
13  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
01/13  
Specifications subject to change without notice  
Printed in USA  
Cat. No. G057-E-1a  
14  
D-sub Connectors XM3/XM2S  

相关型号:

XM3B-2522-111

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2522-112

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2522-131

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2522-501

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2522-501F

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2522-502

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2542-112L

D-sub Connectors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2542-132L

D-sub Connectors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-2542-502L

D-sub Connectors

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-3722

D Subminiature Connector, 37 Contact(s), Female, Solder Terminal, Socket,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-3722-111

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

XM3B-3722-131

D Subminiature Connector

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON