Round Water-resistant Connectors (M12 Threads)
XS2
CSM_XS2_DS_E_11_8
Water- and Environment-resistive
FA Connectors Save Wiring and
Maintenance Effort
• Compact FA connectors meet IP67 requirements and ensure a
94V-0 fire retardant rating.
• A wide array of connectors makes a wiring system more
modular, simplifies maintenance, and reduces downtime.
• Connectors with Cables and Connector Assemblies are available.
• Three types of Connector Assembly: Crimping, soldering, and
screw-on.
• Connectors with Cables are UL certified.
• Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Refer to Safety Precautions on page 32.
Model Number Legend
Connectors with Cables Model Number Legend
XS5: One-touch Smartclick Connection *
(compatible with M12 connectors)
XS2: M12 Screw Connection
Connector
Cable specifications
Cable length (m)
Model
Reference page
Cable length (m)
Model
0.5
1
XS2W-D421-B81-F
XS2W-D421-C81-F
XS2W-D421-D81-F
XS2W-D421-E81-F
XS2W-D421-F81-F
XS2W-D421-G81-F
XS2W-D421-J81-F
XS2W-D421-K81-F
XS2W-D421-L81-F
XS2W-D421-D81-SA
XS2W-D421-G81-SA
XS2F-D421-C80-F
XS2F-D421-D80-F
XS2F-D421-E80-F
XS2F-D421-G80-F
XS2F-D421-J80-F
XS2F-D421-K80-F
XS2F-D421-L80-F
XS2F-D421-D80-SA
XS2F-D421-G80-SA
XS2H-D421-A80-F
XS2H-D421-B80-F
XS2H-D421-C80-F
XS2H-D421-D80-F
—
0.5
1
XS5W-D421-B81-F
XS5W-D421-C81-F
XS5W-D421-D81-F
XS5W-D421-E81-F
XS5W-D421-F81-F
XS5W-D421-G81-F
XS5W-D421-J81-F
XS5W-D421-K81-F
XS5W-D421-L81-F
XS5W-D421-D81-SA
XS5W-D421-G81-SA
XS5F-D421-C80-F
XS5F-D421-D80-F
XS5F-D421-E80-F
XS5F-D421-G80-F
XS5F-D421-J80-F
XS5F-D421-K80-F
XS5F-D421-L80-F
XS5F-D421-D80-SA
XS5F-D421-G80-SA
XS5H-D421-A80-F
XS5H-D421-B80-F
XS5H-D421-C80-F
XS5H-D421-D80-F
XS5H-D421-E80-F
XS5H-D421-G80-F
XS5H-D421-A80-SA
XS5H-D421-C80-SA
2
2
3
3
Fire-retardant, robot
cable
4
4
Connectors on both
cable ends
5
4
5
10
15
20
2
10
15
20
2
Spatter-resistant cable
5
5
1
1
2
2
3
3
Fire-retardant, robot
cable
5
5
Connector on one cable
end
10
15
20
2
6
10
15
20
2
(Socket)
Spatter-resistant cable
5
5
0.3
0.5
1
0.3
0.5
1
Fire-retardant, robot
cable
Connector on one cable
end
2
2
13
3
3
(Plug)
5
XS2H-D421-G80-F
XS2H-D421-A80-SA
XS2H-D421-C80-SA
5
0.3
1
0.3
1
Spatter-resistant cable
*For details, refer to the data sheet of the XS5 Round Water-resistant Connectors (M12 Smartclick).
Note 1. Only DC, straight, 4-core types, and common cable specifications are shown above. Refer to the relevant pages for other products.
2. Other than the M12 sizes introduced above, M8-sized (XS3) products are also available.
For details, refer to the data sheet of the XS3 Round Water-resistant Connectors (M8/S8).
XS2: M12 Screw Connection
XS5: One-touch Smartclick Connection*
(compatible with M12 screws)
Note: Screw connections will be made if connecting with a screw type.
Socket side
Plug side
Socket side
Plug side
Turn approx. 1/8 of a turn to connect Connections can be checked using markings
*For details, refer to the data sheet of the XS5 Round Water-resistant Connectors (M12 Smartclick).
1
XS2
Ratings and Specifications
Rated current
4 A
Rated voltage
250 VAC/VDC
Contact resistance (Connector)
Insulation resistance
Dielectric strength (Connector)
Degree of protection
Insertion tolerance
40 mΩ max. (20 m V max. and 100 mA max.)
1,000 MΩ min. (at 500 VDC)
1,500 VAC for 1 min (leakage current: 1 mA max.)
IP67 (IEC60529)
200 times
Cable diameter: 6 mm
4 to 5 mm 49 N/15 s
3 mm 29 N/15 s
98 N/15 s
Cable holding strength
Ambient operating temperature range
Ambient humidity range
−25 to 70°C *
20% to 85%
*Use the robot cable within a temperature range between 0°C and 70°C to prevent the wires inside the cable from being broken when bending it.
Materials and Finish
Item
Model
XS2F/H/W
Copper alloy/Gold plating
Brass/Copper alloy *
PBT resin
XS2F-LED
XS2M/R/P
XS2C/G
Contacts
Thread bracket
Pin block
O-ring
Brass
PA resin
PBT resin
PBT resin
Rubber
Cover
Soft PBT resin
TPU resin
—
—
UL AWM2464 CL3, 6 mm dia.
AWG20
Fire-retardant, Robot cable
—
—
—
—
Non-polar DC Connectors
with Standard cable
6 mm dia.
AWG20
—
—
E2E models with conventional
connector pin with Fire-
retardant, Robot cable
UL AWM2464 CL3, 6 mm dia.
AWG20
—
—
Cable
Heat-resistant cable up to
105°C
6 mm dia.
AWG20
—
—
—
—
—
—
6.6 mm dia.
AWG20
Spatter-resistant cable
UL AWM2464
Standard cable
(XS2F-LED)
5.0 mm dia. (3 conductors)
5.4 mm dia. (4 conductors)
0.34 mm2
—
—
—
*The T-joint of the XS2R is aluminum/white.
Pin Arrangement (Engaged Side)
Item
No. of poles
4 poles
5 poles
1
5
1
4
Male (plug) contacts
4
2
2
3
2
3
DC type
2
5
Female (socket)
contacts
3
1
3
1
4
4
1
4
Male (plug) contacts
---
---
2
3
2
AC type
Female (socket)
contacts
3
1
4
Note: The AC and DC mating section forms are different as shown here and therefore cannot be connected together.
Connections
Connection Combinations
M12 Plug Connectors
Smartclick Plug Connectors
XS5H, XS5G, XS5W (plug side),
XS5R (plug side), XS5M
OMRON model No.
XS2H, XS2G, XS2W (plug side),
XS2R (plug side), XS2M
XS2F, XS2C, XS2W (socket side),
XS2R (socket side), XS2P
M12 Socket Connectors
❍
❍
❍
Smartclick Socket
Connectors
XS5F, XS5C, XS5W (socket side),
XS5R (socket side), XS5P
: Connected by twisting.
❍: Connected by screwing.
Note: The XS@M and XS@P cannot mate with each other.
2
XS2
XS2WSockets and Plugs on Both Cable Ends
Model Number Structure
Model Number Legend
Use this model number legend to identify products from their model number. Use this model number legend to identify products from their
model number. When ordering, use a model number from the table in Ordering Information.
9
XS2W-D@2@-@@1-@@
1
2
3
4
5
6
7
8
1. Type
W: Connectors with cables, socket and plug on both cable ends
2. AC/DC (Mating Section Form)
D: For DC
3. Connector Poles
4: 4 poles
5: 5 poles
4. Contact Plating
2: Gold plating
5. Cable Connection Direction
1: Straight (socket)/Straight (plug)
2: Right-angle (socket)/Right-angle (plug)
3: Straight (socket)/Right-angle (plug)
4: Right-angle (socket)/Straight (plug)
6. Cable Length
A : 0.3 m (straight/straight only)
B : 0.5 m (straight/straight only)
C : 1 m (straight/straight only)
D : 2 m
E : 3 m (straight/straight only)
F : 4 m (straight/straight only)
G : 5 m
H : 7 m (straight/straight only)
J : 10 m (straight/straight only)
K : 15 m (straight/straight only)
L : 20 m (straight/straight only)
7. Connections (Numbers inside circles are terminal numbers)
8 : A Brown, B White, C Blue, D Black (for DC)
G : A Brown, B White, C Blue, D Black, E Gray
8. Connectors on One End/Both Ends
1: Both ends
9. Cable Specifications
F
: Fire-retardant, Robot cable
SA : Spatter-resistant cable
3
XS2
XS2WSockets and Plugs on Both Cable Ends
Ordering Information
Cable
No. of
Cable core
Cable
DC
Cable connection
Cable specifications
diameter cable cross-sectional length L
(mm)
UL
direction
Model
cores
area (mm2)
(m)
0.5
1
XS2W-D421-B81-F
XS2W-D421-C81-F
XS2W-D421-D81-F
XS2W-D421-E81-F
XS2W-D421-F81-F
XS2W-D421-G81-F
XS2W-D421-J81-F
XS2W-D421-K81-F
XS2W-D421-L81-F
XS2W-D422-D81-F
XS2W-D422-G81-F
XS2W-D423-D81-F
XS2W-D423-G81-F
XS2W-D424-C81-F
XS2W-D424-D81-F
XS2W-D424-G81-F
XS2W-D424-J81-F
XS2W-D421-D81-SA
XS2W-D421-G81-SA
2
3
Straight (Plug)/
Straight (Socket)
4
5
10
15
20
2
UL 2238
certified
(File No.
E207683)
Fire-retardant,
Robot cable
6.0 dia.
4
0.5
Right-angle (Plug)/
Right-angle (Socket)
5
2
Straight (Socket)/
Right-angle (Plug)
5
1
2
Right-angle (Socket)/
Straight (Plug)
5
10
2
Straight (Plug)/
Straight (Socket)
Spatter-resistant cable
6.6 dia.
—
5
Note: Ask your OMRON representative about other cable lengths, and about 5-core cables.
4
XS2
Dimensions
(Unit: mm)
Straight (Socket)/Straight (Plug)
Fire-retardant, Robot cable
XS2W-D421-@81-F
Spatter-resistant cable
XS2W-D421-D81-SA
45°
M12×1
5 dia.
M12×1
5 dia.
45°
14.9 dia.
14.9 dia.
40.7
44.7
L
Right-angle/Right-angle
Fire-retardant, Robot cable
XS2W-D422-@81-F
L
25.3
25.3
Wiring Diagram for 4 Cores
28.3
32.3
Contact No.
Cable lead
colors
1
2
3
4
1
Brown
2 White
3 Blue
4
Black
(DC)
14.9 dia.
14.9 dia.
M12×1
5 dia.
M12×1
5 dia.
45°
45°
Straight (Socket)/Right-angle (Plug)
Fire-retardant, Robot cable
XS2W-D423-@81-F
Wiring Diagram for 5 Cores
L
40.7
25.3
Contact No.
Cable lead
colors
M12×1
5 dia.
45°
1
2
3
4
5
1
Brown
2
3
4
5
White
Blue
Black
Gray
14.9 dia.
32.3
14.9 dia.
M12×1
5 dia.
45°
Right-angle (Socket)/Straight (Plug)
Fire-retardant, Robot cable
XS2W-D421-@81-F
L
25.3
44.7
M12×1
5 dia.
45°
14.9 dia.
28.3
14.9 dia.
M12×1
5 dia.
45°
5
XS2
XS2FSocket on One Cable End
Model Number Structure
Model Number Legend
Use this model number legend to identify products from their model number. Use this model number legend to identify products from their
model number. When ordering, use a model number from the table in Ordering Information.
XS2F-@@2@-@@0-@@
1
2
3
4
5
6
7
8
9
1. Type
9. Cable Specifications
F: Connector with cables, socket on one cable end
F: Standard cable (Fire-retardant, Robot cable)
E: Heat-resistant cable up to 105°C
SA: Spatter-resistant cable
2. AC/DC (Mating Section Form)
A: For AC
D: For DC
A: Standard cable
Note: E type and SA type is a 4-core cable.
E: For DC, stainless steel lock
3. Connector Poles
4: 4 poles
5: 5 poles
4. Contact Plating
2: Gold plating
5. Cable Connection Direction
1: Straight
2: Right-angle
6. Cable Length
A : 0.3 m
B : 0.5 m
C : 1 m
D : 2 m
E : 3 m
F : 4 m
G : 5 m
H : 7 m
J : 10 m
K : 15 m
L : 20 m
Designations for Non-polar DC
(For Limit Switches and Sensors)
Note: Only the 2 m (D), 5 m (G) and 10 m (J) cables are available for cables
with 5 poles.
6. Cable Length
3: 2 m
4: 5 m
7. Connections
(Numbers inside circles are terminal numbers)
A : A Brown, B ---,
B : A ---, B ---,
C : A Brown, B ---,
D : A ---, B ---,
C ---,
D Blue (for DC)
7. Connections
C Brown, D Blue (for AC)
C Blue, D Black
C Blue, D Brown
(Numbers inside circles are terminal numbers)
1: A ---, B ---, C Black, D White
8 : A Brown, B White, C Blue, D Black (for DC)
9 : A Brown, B White, C Blue, D Black (for AC)
G : A Brown, B ---, C Blue, D Black, E Gray
8. Connectors on One End/Both Ends
0: One end
9. Cable Specifications
8. Connectors on One End/Both Ends
Not designated.
0: One end
Note: DC non-polarity models have different specific codes. (6, 7 and 9)
6
XS2
XS2FSocket on One Cable End
Ordering Information
Cable core
cross-
DC
AC
Cable
No. of
Cable
Cable
length
L (m)
Cable
specifications
connection cable diameter
direction
UL
sectional
Model
Model
cores
(mm)
area (mm2)
2
3
4
2
3
4
4
2
3
4
2
3
XS2F-D421-CA0-F
XS2F-D421-CC0-F
XS2F-D421-C80-F
XS2F-D421-DA0-F
XS2F-D421-DC0-F
XS2F-D421-D80-F
XS2F-D421-E80-F
XS2F-A421-CB0-F
1
—
XS2F-A421-C90-F
XS2F-A421-DB0-F
—
2
3
5
XS2F-A421-D90-F
—
Straight
XS2F-D421-GA0-F XS2F-A421-GB0-F
XS2F-D421-GC0-F
XS2F-D421-G80-F
XS2F-D421-JA0-F
XS2F-D421-JC0-F
XS2F-D421-J80-F
XS2F-D421-K80-F
XS2F-D421-L80-F
XS2F-D422-CA0-F
XS2F-D422-CC0-F
XS2F-D422-C80-F
XS2F-D422-DA0-F
XS2F-D422-DC0-F
XS2F-D422-D80-F
XS2F-D422-E80-F
—
XS2F-A421-G90-F
XS2F-A421-JB0-F
10
—
XS2F-A421-J90-F
UL 2238
certified
(File No.
E207683)
4
15
20
—
Fire-retardant,
Robot cable
—
2
3
4
2
3
4
4
2
3
4
2
3
4
2
2
2
2
2
2
2
XS2F-A422-CB0-F
1
—
—
XS2F-A422-DB0-F
2
3
5
—
—
—
6.0 dia.
0.5
Right-angle
XS2F-D422-GA0-F XS2F-A422-GB0-F
XS2F-D422-GC0-F
XS2F-D422-G80-F
XS2F-D422-JA0-F
XS2F-D422-JC0-F
XS2F-D422-J80-F
XS2F-D421-310
XS2F-D421-410
XS2F-D422-310
XS2F-D422-410
XS2F-D421-DD0
XS2F-D421-GD0
XS2F-D422-DD0
—
—
XS2F-A422-JB0-F
10
—
—
XS2F-A421-310
XS2F-A421-410
XS2F-A422-310
XS2F-A422-410
—
2
5
2
5
2
5
2
Straight
Non-polar DC
Connectors with
Standard cable
—
—
Right-angle
Straight
E2E models with
conventional
connector pin with
Fire-retardant,
Robot cable
—
—
Right-angle
2
5
XS2F-D422-GD0
—
2
5
XS2F-E421-D80-E
XS2F-E421-G80-E
XS2F-E422-D80-E
XS2F-E422-G80-E
XS2F-D421-D80-SA
XS2F-D421-G80-SA
XS2F-D521-DG0-A
XS2F-D521-GG0-A
XS2F-D521-JG0-A
XS2F-D522-DG0-A
XS2F-D522-GG0-A
—
—
—
—
—
—
—
—
—
—
—
Straight
Heat-resistant
cable up to
105°C *
4
—
—
2
Right-angle
Straight
5
2
Spatter-
resistant cable
4
5
6.6 dia.
6.0 dia.
5
2
Straight
5
Standard cable
0.3
10
2
—
Right-angle
5
Note: Ask your OMRON representative about other cable lengths.
*The heat-resistant fixture material is SUS316L stainless steel without surface treatment.
7
XS2
Dimensions
(Unit: mm)
Straight Connectors
Fire-retardant, Robot cable
XS2F-D421-@@0-F
XS2F-A421-@@0-F
Non-polar DC Connectors with Standard cable
XS2F-D421-@@0
XS2F-A421-@@0
E2E models with conventional connector pin with Fire-retardant, Robot cable
XS2F-D421-@@0
Heat-resistant cable up to 105°C
XS2F-E421-@80-E
Spatter-resistant cable
XS2F-D421-@80-SA
×
×
1
5 dia.
M12
5 dia.
1
M12
45°
45°
6 dia.
14.9 dia.
40.7
30
5
DC
AC
L
50
Right-angle Connectors
Fire-retardant, Robot cable
XS2F-D422-@@0-F
XS2F-A422-@@0-F
Non-polar DC Connectors with Standard cable
XS2F-D422-@@0
XS2F-A422-@@0
E2E models with conventional connector pin with Fire-retardant, Robot cable
XS2F-D422-@@0
Heat-resistant cable up to 105°C
XS2F-E422-@80-E
L
25.3
6 dia.
28.3
30
5
50
14.9 dia.
×
×
M12
1
M12
5 dia.
1
5 dia.
DC
AC
45°
45°
Wiring Diagram
Two-core
Three-core
Four-core
Fire-retardant,
Robot cable
Contact No.
Cable lead
colors
XS2F-
@
42
@
-
@@0-F
1
2
3
4
Brown
Contact No.
Cable lead
colors
Contact No.
Cable lead
colors
Blue
(DC)
Spatter-resistant
cable *
XS2F-D421-
@
80-SA
80-E
1
2
3
4
1
2
3
4
Brown
White
Blue
Black
(DC/AC)
Brown
Blue
Black
(DC)
Contact No.
Cable lead
colors
1
2
3
4
Heat-resistant
cable up to 105°C *
XS2F-E42
@
-
@
Brown
Blue
(AC)
Contact No.
Cable lead
colors
Non-polar DC
Connectors with
Standard cable
1
2
3
4
XS2F-
@
42
@
-
@@
0
—
—
—
—
Black
White
E2E models with
conventional
connector pin with XS2F-D42
Fire-retardant,
Contact No.
Cable lead
colors
1
2
3
4
@-@D0
Blue
Brown
Robot cable
*Spatter-resistant Cables and Heat-resistant Cables (105°C) are available only for four cores and DC.
8
XS2
Dimensions
(Unit: mm)
Straight
Note:
Standard cable
XS2F-D521-@G0-A
Use the XS2H-D521-@G0-A in combination
with the XS2F-D521-@G0-A.
×
M12
1
45°
6 dia.
5 dia.
14.9 dia.
40.7
30
5
L
50
Wiring Diagram
Contact No.
Cable lead
colors
Brown
White
Blue
Black
Gray
1
2
3
4
5
Right-angle
L
Standard cable
XS2F-D522-@G0-A
25.3
6 dia.
28.3
30
5
50
M12
For details on connecting with E2E Proximity Sensors, refer to E2E Small-diameter Proximity Sensor Data Sheet (Cat. No.:
SCEC-044).
9
XS2
Connectors with Cables, Socket on One Cable End,
XS2F-G/H
Model Number Structure
Model Number Legend
Use this model number legend to identify products from their model number. Use this model number legend to identify products from their
model number. When ordering, use a model number from the table in Ordering Information.
XS2F-@42@-@@@-F
1
2
3
4
5
1. Type
F: Connector with cables, sockets on one cable end
2. AC/DC
G: For DC
H: For AC
3. Cable Connection Direction
1: Straight
2: Right-angle
4. Cable Length
G80 : 5m (for DC)
G90 : 5m (for AC)
J80 : 10m (for DC)
J90 : 10m (for AC)
5. Structure
Screw Loosening-preventing
Ordering Information
DC
Model
AC
Model
Cable connection
No. of cable cores
direction
Cable length L (m)
UL
5
10
5
XS2F-G421-G80-F
XS2F-G421-J80-F
XS2F-G422-G80-F
XS2F-G422-J80-F
XS2F-H421-G90-F
XS2F-H421-J90-F
XS2F-H422-G90-F
XS2F-H422-J90-F
Straight
UL 2238 certified
(File No. E207683)
4
Right-angle
10
10
XS2
Dimensions
(Unit: mm)
Straight
XS2F-G421-@80-F
XS2F-G421-@90-F
M12 × 1
5 dia.
M12 × 1
5 dia.
45°
45°
6 dia.
14.9 dia.
DC
AC
40.7
30
5
L
50
Right-angle
XS2F-G422-@80-F
XS2F-G422-@90-F
L
25.3
6 dia.
4
5
6
7
28.3
30
5
50
14.9 dia.
M12 × 1
5 dia.
M12 × 1
5 dia.
DC
AC
45°
45°
Features
Screw Loosening-preventing Structure
Appearance
Black nickel plating
Structure
Convex and
Ribbed portion
concave portion
By the above structure, the convex and concave portion of the thread bracket and housing ribs interfere with each other at 45°
increments to work as a loosening-preventing mechanism when engaged.
11
XS2
XS2FSockets on One Cable End with Indicator
Model Number Structure
Model Number Legend
Use this model number legend to identify products from their model number. Use this model number legend to identify products from their
model number. When ordering, use a model number from the table in Ordering Information.
XS2F-M12PVC@A@@M@LED
1
2
3
4
5
6
7
8
1. Type
4. Connector Poles
7. Applicable Sensors
F: Connector with cables, sockets
on one cable end
3: 3 poles
4: 4 poles
P: PNP
N: NPN
2. Mating Section Form
5. Cable Connection Direction
8. With indicator
M12: M12
A: Right-angle
LED: With indicator
3. Cable Material
6. Cable Length
PVC: PVC
2 : 2 m
5 : 5 m
10 : 10 m
Ordering Information
Cable
diameter
(mm)
No. of Cable core cross-
Cable
length L
(m)
Cable connection
direction
Cable specifications
cable
cores
sectional area
LED
Model
UL
(mm2)
2
5
XS2F-M12PVC3A2MPLED
PNP XS2F-M12PVC3A5MPLED
XS2F-M12PVC3A10MPLED
XS2F-M12PVC3A2MNLED
10
2
5 dia.
3
4
UL 2238
certified
(File No.
E207683)
PVC
Right-angle
0.34
5
NPN XS2F-M12PVC3A5MNLED
XS2F-M12PVC3A10MNLED
XS2F-M12PVC4A2MPLED
PNP XS2F-M12PVC4A5MPLED
XS2F-M12PVC4A10MPLED
10
2
5.4 dia.
5
10
Dimensions
(Unit: mm)
L
Right-angle
XS2F-M12PVC3A@MPLED
XS2F-M12PVC4A@MPLED
5
35
28.2
30
28
9.1
50
14.9 dia.
M12×1
Wiring Diagram
3 poles
4 poles
PNP
NPN
PNP
1
2
4
+
1
+
BROWN
+
BROWN
WHITE
BLACK
1
4
BROWN
YELLOW
GREEN
BLACK
R1
D1
R2
D2
R3
D3
4
3
BLACK
BLUE
YELLOW
GREEN
3
-
BLUE
-
-
BLUE
3
12
XS2
XS2HPlugs on One Cable End
Model Number Structure
Model Number Legend
Use this model number legend to identify products from their model number. When ordering, use a model number from the table
in Ordering Information.
XS2H-@@21-@@0-@@
1
2
3
8
9
1. Type
H: Connector with cables, plug on one cable end
2. AC/DC
A: For AC
D: For DC
3. Connector Poles
4: 4 poles
5: 5 poles
4. Contact Plating
2: Gold plating
5. Cable Connection Direction
1: Straight
6. Cable Length
A : 0.3 m
B : 0.5 m
C : 1 m
D : 2 m
G : 5 m
7. Connections (Numbers inside circles are terminal numbers)
8 : A Brown, B White, C Blue, D Black (for DC)
9 : A Brown, B White, C Blue, D Black (for AC)
A : A Brown, B ---,
B : A ---, B ---,
C : A Brown, B ---,
C ---,
D Blue (for DC)
C Brown, D Blue (for AC)
C Blue, D Black (for DC)
G : A Brown, B White, C Blue, D Black, E Gray
8. Connectors on One End/Both Ends
0: One end
9. Cable Specifications
A
F
:Standard cable
:Fire-retardant, Robot cable
SA :Spatter-resistant cable
13
XS2
XS2HPlugs on One Cable End
Ordering Information
Cablecore
cross-
DC
AC
No. of
Cable
Cable
No. of
Cable
length
L (m)
Cable
specifications
connector connection diameter cable
poles
UL
sectional
Model
Model
direction
(mm)
cores
area (mm2)
2
3
XS2H-D421-AA0-F XS2H-A421-AB0-F
0.3 XS2H-D421-AC0-F
XS2H-D421-A80-F
—
XS2H-A421-A90-F
—
4
UL 2238
certified
(File No.
E207683)
0.5 XS2H-D421-B80-F
Fire-retardant,
Robot cable
4
6.0 dia.
2
3
XS2H-D421-CA0-F XS2H-A421-CB0-F
0.5
0.3
1
XS2H-D421-CC0-F
XS2H-D421-C80-F
XS2H-D421-D80-F
XS2H-D421-G80-F
—
Straight
Connectors
XS2H-A421-C90-F
4
2
5
—
—
—
—
—
—
0.3 XS2H-D421-A80-SA
XS2H-D421-C80-SA
0.3 XS2H-D521-AG0-A
Spatter-
resistant cable
4
5
6.6 dia.
6.0 dia.
4
5
1
—
Standard
cable
1
XS2H-D521-CG0-A
Note: Ask your OMRON representative about other cable lengths.
Dimensions
(Unit: mm)
Straight (4 poles)
Fire-retardant, Robot cable XS2H-@421-@@0-F
Spatter-resistant cable XS2H-D421-@80-SA
44.7
×
M12
5 dia.
1
45°
45°
5 dia.
6 dia.
14.9 dia.
DC
AC
30
5
L
50
Wiring Diagram
Two-cores
Three-cores
Four-cores
Contact No.
Cable lead
colors
1
2
3
4
Brown
Contact No.
Cable lead
colors
Contact No.
Cable lead
colors
Blue
(DC)
1
2
3
4
1
2
3
4
Brown
White
Blue
Black
(DC/AC)
Brown
Blue
Black
(DC)
Contact No.
Cable lead
colors
1
2
3
4
Brown
Blue
(AC)
Straight (5 poles)
Standard cable XS2H-D521-@G0-A (For DC)
Note:
Use the XS2F-D521-@G0-A in combination
with the XS2H-D521-@G0-A.
×
M12
1
45°
6 dia.
5 dia.
14.9 dia.
44.7
30
5
L
50
Wiring Diagram
Five-cores
Contact No.
Cable lead
colors
Brown
White
Blue
1
2
3
4
Black
Gray
5
14
XS2
XS2@Sensor I/O Connectors on Cables (8-pole)
Ordering Information
Cable
connection
direction
Cable
length L
(m)
Applicable
wire
diameter
Number of
cores
Connector type
Panel-mounting Plug
Model
UL
XS2M-D824-4
—
—
—
8
—
AWG22 to 28 XS2P-D821-2
Panel-mounting socket
XS2P-D822-2
XS2H-D821-AH0-C
0.3
1
UL 2238
certified
(File No.
E207683)
Plug on one cable end
XS2H-D821-CH0-C
XS2F-D821-DH0-C
XS2F-D821-GH0-C
XS2W-D821-DH1-C
XS2W-D821-GH1-C
2
Socket on one cable end
Plug and socket on both cable ends
Straight
—
5
2
5
Note: Ask your OMRON representative about other cable lengths.
Ask your OMRON representative about robot cable models (-R).
Ratings and Specifications
Rated current
Rated voltage
1.5 A
36 VDC
40 mΩ max.
(at 20 mVDC max. and 100 mA max.)
Contact resistance
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC for 1 min (leakage current: 1 mA max.)
Degree of protection
IP67
Insertion tolerance
Ambient operating temperature range
200 times min.
−25 to 70°C
Materials and Finish
Contacts
Thread Bracket, body, M16 nuts
Pin block
Cover *1
Seal rubber and O-ring *2
Brass, gold plating
Brass/nickel plated
PBT resin, light gray
Soft PBT resin
Rubber
6 mm dia.
AWG24
Cable
Standard cable (8 core)
*1. XS2F/XS2H/XS2W only.
*2. O-rings are on sockets only.
Pins and Cable Lead Colors
Pin No.
1
2
3
4
5
6
7
8
XS2F/XS2H/XS2W cable lead
colors
White
Brown
Green
Yellow
Gray
Pink
Blue
Shield
Wiring
Wiring Example
Relay box,
In-panel terminal block
Sensor, actuator, etc.
XS2M
XS2P
XS2F
XS2W
XS2H
15
XS2
Dimensions
(Unit: mm)
Plug on One Cable End (M12)
XS2H
1
5
2
6 dia.
7
6
3
14.9 dia.
4
8
×
M12
1
30
5
44.7
L
50
Socket on One Cable End (M12)
XS2F
2
5
1
8
6 dia.
7
3
4
14.9 dia.
6
×
M12
1
30
5
40.7
L
50
Socket and Plug on Both Cable Ends (M12)
XS2W
×
M12
1
5
1
8
4
2
5
1
7
6 dia.
6
7
3
4
14.9 dia.
14.9 dia.
3
2
6
8
44.7
×
M12
1
40.7
L
Panel-mounting Socket (M12)
Rear Lock Model
Panel-mounting Plug (M12)
Front Lock Model
XS2P-D821-2 (with Solder Cup Pins)
XS2M-D824-4 (with Solder Cup Pins)
Panel
20.9
8.7
5
Panel
M16 nut
3
1.5
Seal rubber
3
3 3
20 dia.
7
10.6 dia.
7
20 dia. 14 dia.
×
M12
M16
M16 nut
Seal rubber
1
×
M12
1
×
×
1
M16
1
2.5
10.5
3
20.4
5
Panel-mounting Socket (M12)
Front Lock Model
XS2P-D822-2 (with Solder Cup Pins)
Panel Cutout
Connector Terminal Numbers
(from Connection Side)
7+0.1
2
1
1
2
16+0.2 dia.
0
0
3
7
6
7
6
3
Seal rubber
1.5
3
Panel
M16 nut
4
4
8
8
5
5
7 20 dia. 14 dia.
24 min.
14 dia.
Plug
Socket
Note: 1. Mounting panel thickness: 1 to 4 mm.
2. Applicable core wire size for solder cup pins: 0.5 mm2 max.
3. The M16 nut and seal rubber are included.
×
×
1
8.7
3
6
5
M12
1
M16
20.4
16
XS2
XS2GCrimping/Soldering Plug Assemblies
Ordering Information
Cable
connection
direction
DC
AC
Suitable cable
(mm)
Core conductor Suitable sheath
Connection
method
UL
size (mm2)
material
Model
Model
0.18 to 0.3
Crimping
Soldering
Crimping
Soldering
Crimping
Soldering
XS2G-D4C1 XS2G-A4C1
XS2G-D421 XS2G-A421
0.5 to 0.75*
0.5 max.
Straight
6 dia. (5 to 6 dia.)
4 dia. (4 to 5 dia.)
3 dia. (3 to 4 dia.)
Right-angle
Straight
XS2G-D422
—
0.18 to 0.3
0.5 to 0.75*
UL 2238
certified
XS2G-D4C3 XS2G-A4C3
PVC, PE, PUR
XS2G-D423 XS2G-A423 (File No.
E207683)
0.5 max.
Right-angle
Straight
XS2G-D424
—
0.18 to 0.3
0.5 to 0.75*
XS2G-D4C5 XS2G-A4C5
XS2G-D425 XS2G-A425
0.5 max.
Right-angle
XS2G-D426
—
*There are two types of contacts.
Note: Crimping plug pins are sold separately.
Use a cable of mentioning. If you do not use one of these cables, there is a possibility that the performance can’t be met.
Ask your OMRON representative about selecting a cable of other than above.
Dimensions
(Unit: mm)
Straight Connectors
XS2G-@4C@ (Crimping Model)
XS2G-@42@ (Soldering Model)
45°
45°
×
M12
1
5 dia.
5 dia.
14.9 dia.
14.2 dia.
47.1
35.7
DC
AC
Right-angle
45°
5 dia.
XS2G-D42@ (Soldering Model)
14.9 dia. M12 × 1
23
DC
XS2UCrimping Pin for XS2G
Ordering Information
Suitable core size (mm2)
0.18 to 0.3
Model
XS2U-3121
XS2U-3122
0.5 to 0.75
Dimensions
(Unit: mm)
* A special tool must be used for crimping. For details, refer to page 31.
XS2U-312@
Slit
Dimensions
Dimension (mm)
Suitable core
size (mm2)
No. of
slits
1 dia.
2 dia. 2.3 dia.
Model
C dia.
A
B
C
1.5
XS2U-3121
XS2U-3122
0.18 to 0.3 20.0 6.1
0.5 to 0.75 20.1 6.2
0.8
1.3
1
0
B
A
17
XS2
XS2CCrimping/Soldering Socket Assemblies
Ordering Information
Cable
connection
direction
DC
AC
Suitable cable
(mm)
Core conductor Suitable sheath
Connection
method
UL
size (mm2)
material
Model
Model
0.18 to 0.3
0.5 to 0.75*
0.5 max.
0.18 to 0.3
0.5 to 0.75*
0.5 max.
0.18 to 0.3
0.5 to 0.75*
0.5 max.
0.18 to 0.3
0.5 to 0.75*
0.5 max.
0.18 to 0.3
0.5 to 0.75*
0.5 max.
0.18 to 0.3
0.5 to 0.75*
0.5 max.
Crimping
Soldering
Crimping
Soldering
Crimping
Soldering
Crimping
Soldering
Crimping
Soldering
Crimping
Soldering
XS2C-D4C1 XS2C-A4C1
XS2C-D421 XS2C-A421
XS2C-D4C2 XS2C-A4C2
XS2C-D422 XS2C-A422
XS2C-D4C3 XS2C-A4C3
XS2C-D423 XS2C-A423
XS2C-D4C4 XS2C-A4C4
XS2C-D424 XS2C-A424
XS2C-D4C5 XS2C-A4C5
XS2C-D425 XS2C-A425
XS2C-D4C6 XS2C-A4C6
XS2C-D426 XS2C-A426
Straight
6 dia. (5 to 6 dia.)
4 dia. (4 to 5 dia.)
3 dia. (3 to 4 dia.)
Right-angle
Straight
UL 2238
certified
(File No.
E207683)
PVC, PE, PUR
Right-angle
Straight
Right-angle
*There are two types of contacts.
Note: Crimping plug contacts are sold separately.
Use a cable of mentioning. If you do not use one of these cables, there is a possibility that the performance can’t be met.
Ask your OMRON representative about selecting a cable of other than above.
Dimensions
(Unit: mm)
Straight Connectors
45°
45°
5 dia.
M12
5 dia.
M12
×
1
×
1
14.9 dia.
14.2 dia.
43.2
DC
AC
Right-angle Connectors
45°
45°
31.8
5 dia.
M12
5 dia.
M12
×
1
×
1
14.9 dia.
23
DC
AC
XS2UCrimping Pin for XS2C
Ordering Information
Suitable core size (mm2)
0.18 to 0.3
Model
XS2U-2221
XS2U-2222
0.5 to 0.75
Dimensions
(Unit: mm)
* A special tool must be used for crimping. For details, refer to page 31.
Socket Pin
Slit
Dimensions
Dimension (mm)
Suitable core
size (mm2
No. of
slits
2 dia. 2.3 dia.
C dia.
Model
)
A
B
C
1.5
XS2U-2221
XS2U-2222
0.18 to 0.3
0.5 to 0.75
16.7
16.8
6.1
6.2
0.8
1.3
1
0
B
A
18
XS2
XS2GScrew-on Plug Assemblies
Ordering Information
Straight
connectors
(for DC)
Right-angle
connectors
(for DC)
No. of
poles
Core conductor
size (mm2)
Suitable sheath
material
Suitable cable (mm)
UL
Model
Model
—
8 dia. (7 to 8 dia.)
7 dia. (6 to 7 dia.)
6 dia. (5 to 6 dia.)
8 dia. (7 to 8 dia.)
7 dia. (6 to 7 dia.)
6 dia. (5 to 6 dia.)
4 dia. (4 to 5 dia.)
3 dia. (3 to 4 dia.)
XS2G-D5S7
XS2G-D5S9
XS2G-D5S1
XS2G-D4S7
XS2G-D4S9
XS2G-D4S1
XS2G-D4S3
XS2G-D4S5
5
4
—
XS2G-D5S2
—
UL 2238 certified
(File No. E207683)
0.18 to 0.75
PVC, PE, PUR
—
XS2G-D4S2
XS2G-D4S4
XS2G-D4S6
Note: XS2G Screw-on Plugs cannot be connected to side by side to the CN1 and CN2 connectors of XS2R Y-Joint Sockets/Plugs.
Use a cable of mentioning. If you do not use one of these cables, there is a possibility that the performance can’t be met.
Ask your OMRON representative about selecting a cable of other than above.
Dimensions
(Unit: mm)
Straight Connectors
Applicable Cable Outer Diameter: 8 mm
XS2G-D5S7 (5poles)
XS2G-D4S7 (4 poles)
Applicable Cable Outer Diameter: 7 mm
XS2G-D5S9 (5poles)
58.7
M12 × 1
XS2G-D4S9 (4 poles)
20 dia.
16 dia.
14.9 dia.
Straight Connectors
Applicable Cable Outer Diameter: 6 mm
XS2G-D5S1 (5poles)
XS2G-D4S1 (4 poles)
Applicable Cable Outer Diameter: 4 mm
XS2G-D4S3 (4 poles)
58.7
M12 × 1
Applicable Cable Outer Diameter: 3 mm
XS2G-D4S5 (4 poles)
20 dia.
14 dia.
14.9 dia.
Right-angle Connectors
Applicable Cable Outer Diameter: 6 mm
XS2G-D5S2 (5poles)
XS2G-D4S2 (4 poles)
39.7
M12 × 1
Applicable Cable Outer Diameter: 4 mm
XS2G-D4S4 (4 poles)
20 dia. 14.9 dia.
Applicable Cable Outer Diameter: 3 mm
XS2G-D4S6 (4 poles)
39.6
14 dia.
19
XS2
XS2CScrew-on Socket Assemblies
Ordering Information
Straight
connectors
(for DC)
Right-angle
connectors
(for DC)
No. of
poles
Core conductor
size (mm2)
Suitable sheath
material
Suitable cable (mm)
UL
Model
Model
—
8 dia. (7 to 8 dia.)
7 dia. (6 to 7 dia.)
6 dia. (5 to 6 dia.)
8 dia. (7 to 8 dia.)
7 dia. (6 to 7 dia.)
6 dia. (5 to 6 dia.)
4 dia. (4 to 5 dia.)
3 dia. (3 to 4 dia.)
XS2C-D5S7
XS2C-D5S9
XS2C-D5S1
XS2C-D4S7
XS2C-D4S9
XS2C-D4S1
XS2C-D4S3
XS2C-D4S5
5
4
—
XS2C-D5S2
—
UL 2238 certified
(File No. E207683)
0.18 to 0.75
PVC, PE, PUR
—
XS2C-D4S2
XS2C-D4S4
XS2C-D4S6
Note: Use a cable of mentioning. If you do not use one of these cables, there is a possibility that the performance can’t be met.
Ask your OMRON representative about selecting a cable of other than above.
Dimensions
(Unit: mm)
Straight Connectors
Applicable Cable Outer Diameter: 8 mm
XS2C-D5S7 (5 poles)
XS2C-D4S7 (4 poles)
Applicable Cable Outer Diameter: 7 mm
XS2C-D5S9 (5 poles)
XS2C-D4S9 (4 poles)
54.9
M12 × 1
20 dia. 14.9 dia.
16 dia.
Straight Connectors
Applicable Cable Outer Diameter: 6 mm
XS2C-D5S1 (5 poles)
XS2C-D4S1 (4 poles)
Applicable Cable Outer Diameter: 4 mm
XS2C-D4S3 (4 poles)
Applicable Cable Outer Diameter: 3 mm
54.9
M12 × 1
XS2C-D4S5 (4 poles)
20 dia. 14.9 dia.
14 dia.
Right-angle Connectors
Applicable Cable Outer Diameter: 6 mm
XS2C-D5S2 (5 poles)
XS2C-D4S2 (4 poles)
Applicable Cable Outer Diameter: 4 mm
35.9
M12 × 1
XS2C-D4S4 (4 poles)
Applicable Cable Outer Diameter: 3 mm
20 dia. 14.9 dia.
XS2C-D4S6 (4 poles)
39.6
14 dia.
20
XS2
XS2C/XS2G Safety Precautions
Assembly Procedure for XS2C/XS2G Connector Assemblies
(1) Connector and Cable Diameters
(3) Wiring (Dressing the Cable Ends)
•
Connectors for 8, 7, 6, 4, and 3 mm diameter Cables (i.e.,
Cables that are 7 to 8, 6 to 7, 5 to 6, 4 to 5, and 3 to 4 mm in
diameter respectively) are available.
Soldering Connectors
When assembling a Connector used with a cable, make sure
that the external diameter of the Connector is suited to that
of the cable.
• A waterproof bushing for 6/7 mm diameter Cable has no
stripe, that for 8/4 mm diameter Cable has a single stripe,
and that for 3 mm diameter Cable has two stripes.
6
0.5
*A
• Strip 10 mm of the Cable sheath and 4 mm of each core.
• Before soldering cores and solder cup pins together, solder-
coat each of them.
(2) Component Insertion
• The following conditions are recommended for soldering
each solder cup pin.
Crimping/Soldering Connectors
Straight Connectors
Soldering temperature: 350±5°C
Soldering period: 3±1 s
• The length marked *A should be 6.5 mm max., otherwise
the proper degree of protection of the connector will not be
maintained.
Watertight
bushing
Cable
clamp
Cover
Cap
Crimping Connectors
Crimping
Right-angle Connectors
Ring (Right-angle models only) *
Cable clamp
Watertight
bushing
Cap
Cover
• Strip 14 mm of the Cable sheath and 4 mm of each core.
• Make sure that each core is not damaged and its end
strands are not spread out.
• Mount the XY2F-0003 Locator to XY2F-0002 Crimp Tool,
both of which are sold separately, and set the selector dial
of the Crimp Tool to 8.
*A ring is not required for Screw-on Connectors.
• As shown in the above illustration, connect the above
components to the Cable with its end processed.
• After mounting the crimping pins to the Locator, fully insert
the cores to the crimping pins.
Screw-on Connectors
• Squeeze the handle of the Crimp Tool to press-fit the cores
to the crimping pins.
(Squeeze the handle firmly until the handle automatically
returns to the release position.)
Confirm that you have all of the required parts.
Cover
Cable clamp
Cap
Watertight
bushing
Wiring
*2
Pin clamp
Press
Ring *1
Watertight bushing
Cable clamp
Cap
Cover
1 to 1.5
• After press-fitting the cores to the pins, insert the pins into
the pin clamp as shown in the illustration. Then make sure
that the lead colors correspond to the pin clamp numbers
that are identical to the connector pin numbers.
Insulation caps and insulation tubes are included with
5-pole Connectors (XS2C-D5S and XS2G-D5S ).
@
@
*1. Rings are not required with 7-mm and 8-mm cables.
*2. Insert the waterproof bushing for 7-mm and 8-mm cables in the
direction shown in the diagram.
Insertion
Pin Block
Pin Clamp
Key groove Key groove
XS2C use XS2G use
Key
6
0.5
• Tentatively insert the pins to the pin block holes so that the
key on the pin block will coincide with the key groove on the
pin clamp. Then insert the cable along with the pin clamp.
21
XS2
Connecting Shielded Cables to Five-pole Connectors
• Place the insulation tub on the drain line of the shield and
connect it to the terminal.
• Tighten the screw and then check visually to see if there is
insulation between the cores.
Screw-on Connectors
Dressing the Cable End
• Four-pole Connectors
8
12
Drain line
Insulation tube
12 0.5
• Loosen the screws on pins 1 to 4 and insert the cores
according to the pin numbers.
*When tightening the screws, use the dedicated XW4Z-00B Screwdriver
that matches with the screw-slot dimensions.
Screwdriver
XW4Z-00B
• Use the dedicated Screwdriver (XW4Z-00B)* and tighten
the screws securely so that the cores do not pull out. (0.15
to 0.2 N·m)
(4) Inserting Pin Block
• Five-pole Connectors
• Strip the cable sheath for a total of 15 mm and strip the core
covering for 8 mm for the core to connect to pin 5.
Pin block
(Soldering Model)
Cover
(Straight Model)
Lock spring
O-ring
Conductors for
pins 1 to 4
Positioning key
(triangle mark)
Polarity key
Triangle mark
(Right-angle Model)
Conductors for
pin 5
8
7
(Crimping Model)
• Connect the core to pin 5 (in the center) first.
• Insert the core from the side of the hold with the tab and
tighten the screw securely (tightening torque: Pins 1 to 4:
0.15 to 0.2 N·m, Pin 5: 0.03 to 0.05 N·m), and then cut off
the excess wire with wire cutters.
• Mount the cover to the pin block so that the triangle mark on
the pin block will coincide with the triangle mark on the
cover.
Screw
Screw
• If the cover is used for a Right-angle model, the relationship
between the position of the polarity key on the engaged side
and cable connection direction will be determined by the
direction in which the positioning key is inserted into the
cover, which can be rotated by 90°.
Special
Screwdriver
Special
Screwdriver
Tab
• Bend the cable as shown below, attached the enclosed
insulation cap, and then strip the other cores.
• Fully insert the positioning key until the positioning key is
hidden by the casing.
Pin block
(Screw-on Connectors)
Triangle mark
Cover
Insulation cap
Cover lock
Pin block
• Connect the cores to pins 1 to 4.
• Align the triangular marks on the pin block and cover and
insert the pin block into the cover.
• Press them together firmly until the pin block does not come
out of the cover. (0.39 to 0.49 N·m)
22
XS2
(5) Mounting Cap
Recommended Cables
When connecting a commercially available cable to a
• After mounting the cover to the pin block and the cover
snaps into place, tighten the cap securely by hand (0.39 to
0.49 N·m)
connector assembly, use a cable with an outside diameter of
3 to 6 mm and core conductor sizes of 0.18 to 0.75 mm2 for
crimping connectors and 0.5 mm2 maximum for soldering
connectors.
Note: If the cap is not tighten securely enough, the degree of protection (IP67)
may not be maintained or vibration may cause the cap to become loose.
Do not tighten the cap with pliers or similar tools; they may damage the
cap.
Connector Arrangement
For safety, when constructing a connection system between a
Sensor and panel with a connector, make sure that the
connector plug is on the Sensor side and the connector socket
is on the panel side (i.e., the female pins are located on the
power-supply side).
A
Cap
Panel Side
(Power-supply Side)
• After fully tightening the cap, length A should be
approximately one of the following according to the cable
external diameter and the Connector model. (Use these as
a guide.)
Connecting Cable
Sensor Side
(Plug)
Cable external diameter (mm)
(Socket)
(Plug)
(Socket)
External diameter of
applicable cable
6 mm
1
5 mm
0
2
4 mm
—
1
3 mm
—
For 6-mm-dia. cable
For 4-mm-dia. cable
For 3-mm-dia. cable
—
—
—
—
2
1
(6) After Assembly
• Confirm the insulation between cores after completing
assembly.
23
XS2
XS2PPanel-mounting Sockets for Terminal Boxes
Ordering Information
DC
Model
AC
Model
XS2P-A421-2
XS2P-A422-2
XS2P-A422-1
—
No. of
poles
Applicable wire
diameter
Lock method
Rear lock
Pin shape*
UL
Solder cup pin
Solder cup pin
DIP pin
XS2P-D421-2
XS2P-D422-2
XS2P-D422-1
XS2P-D522-2
XS2P-D522-1
UL 2238 certified
(File No. E207683)
4
Front lock
AWG20 to 28
Solder cup pin
DIP pin
5
Front lock
—
—
*The solder cup pin is for wire mounting, and the DIP pin is for PCB mounting. Soldering is required for both pins.
Dimensions
(Unit: mm)
Rear Lock Model
XS2P-@421-2 (with Solder Cup Pins)
Panel
M16 × 1
Rubber bushing
×
×
1
M12
1
M12
20 dia.14.6 dia.
7.8
2.5
7
DC
AC
20.5
24
Front Lock Model
XS2P-@422-1 (with DIP Pins)
XS2P-@422-2 (with Solder Cup Pins)
With Solder Cup Pins
With DIP Pins
Panel
Panel
M16 × 1
M16 × 1
Rubber bushing
Rubber bushing
2 dia.
5 dia.
×
×
1
M12
1
M12
14 dia.
14 dia.
20 dia.
16 dia.
6
7
7
17
8.7
17
23.5
27
2.5
20.5
24
DC
AC
Front Lock Model
XS2P-D522-1 (with DIP Pins)
XS2P-D522-2 (with Solder Cup Pins)
With Solder Cup Pins
With DIP Pins
M16×1
3
M16 × 1
3
M16 nut
1.5
M16 nut
1.5
2 dia.
2 dia.
M12 × 1
0.8 dia.
14 dia.
14 dia.
16 dia.
6.8
8.7
3
6.8
8.7
7
17
17
2.5
2.5
20.5
9
DC
5
23.5
3.5
25.5
Panel Cutout
PCB-mounting
Dimensions
With DIP Pins
7+0.1
16+0.15 dia.
0
0
5
Land
5
Four, 2.2-dia.holes
24 min.
24 min.
Note: The panel thickness is 1 to 4 mm.
24
XS2
XS2RY-Joint Plug/Socket Connectors
Ordering Information
DC
Cable
Connector
UL
Cable length L (m)
Model
0.5
1
2
XS2R-D426-B11-F
XS2R-D426-C11-F
XS2R-D426-D11-F UL 2238 certified
Connectors on
both cable ends
With cable
3
2
5
XS2R-D426-E11-F
XS2R-D426-D10-F
XS2R-D426-G10-F
(File No. E207683)
Connectoronone
cable end
DC
Cable
Connector
UL
Cable length L (m)
Model
XS2R-D426-1
XS2R-D426-5
XS2R-D426-81
XS2R-D426-82
Connectors on
both cable ends
UL 2238 certified
(File No. E207683)
Without cable
—
Note: XS2G Screw-on Plugs cannot be connected side-by-side to the CN1 and CN2 connectors.
Consider using a crimping or soldering model instead. Refer to page 17 for details.
Dimensions
(Unit: mm)
Connectors on Both Cable Ends (Y-Joint Plug/Socket)
XS2R-D426-@11-F
Wiring Diagram
1
2
×
45.5
4.6 dia.
M12
1
15.0
Socket
CN2
3
CN2
4
14.9 dia.
Plug
4
3
2
1
2
3
1
4
6 dia.
4
1
3
2
14.9 dia.
35.0
18.0
1
2
3
4
2
3
1
4
CN1
14.9 dia.
CN1
8.5
×
M12
1
Blue marking
44.7
13.6
L
Connectors on One Cable End (Y-Joint Socket)
XS2R-D426-@10-F
Wiring Diagram
1
2
3
4
15.0
×
45.5
4.6 dia.
M12
1
Socket
CN2
CN2
Black
Blue
14.9 dia.
2
1
6 dia.
3
4
White
Brown
35.0
18.0
1
2
3
2
3
CN1
1
4
14.9 dia.
CN1
8.5
4
13.6
Blue marking
30
5
50
L
Y-Joint Plug/Socket without Cable
XS2R-D426-1
Wiring Diagram
XS2R-D426-1
XS2R-D426-5
4
4
3
2
1
3
2
1
CN2
CN2
27
7
15
×
M12
1
Socket
4.5 dia.
4
3
2
1
CN2
4
3
2
1
4
3
2
1
4
3
2
1
CN0
14.9 dia.
2
CN1
CN1
1
4
CN0
3
CN0
24.5
Plug
(37)
18.0
4
14.9 dia.
12.5
1
2
2
3
1
4
XS2R-D426-81
XS2R-D426-82
3
14.9 dia.
CN1
4
3
2
1
4
3
2
1
CN2
CN2
×
M12
1
58.3
Blue marking
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
CN0
CN0
CN1
CN1
25
XS2
XS2RT-Joint Plug/Socket Connectors
Ordering Information
DC
Model
Type
UL
XS2R-D422-1
XS2R-D422-5
XS2R-D423-1
XS2R-D424-1
Aggregate model
UL 2238 certified
(File No.
E207683)\
Bifurcated model
Daisy-chain model
Dimensions
(Unit: mm)
Aggregate model
XS2R-D422-1
XS2R-D422-5
Wiring Diagram
XS2R-D422-1
A (Female)
B (Female)
4
3
2
1
4
3
2
1
50.6
24.6
×
M12
1
14.6 dia.
A
B
1
2
3
4
C (Male)
C
29
×
M12
1
XS2R-D422-5
A (Female)
B (Female)
4
3
2
1
4
3
2
1
1
2
3
4
C (Male)
Bifurcated model
XS2R-D423-1
Wiring Diagram
50.6
24.6
A (Male)
B (Male)
4
3
2
1
4
3
2
1
A
B
×
M12
1
C
29
1
2
3
4
C (Female)
14.6 dia.
×
M12
1
Daisy-chain model
XS2R-D424-1
Wiring Diagram
50.6
24.6
A (Female)
B (Male)
×
M12
1
4
3
2
1
4
3
2
1
14.6 dia.
A
B
×
M12
1
C
29
1
2
3
4
C (Female)
26
XS2
Features
XS2R Application Examples
XS2R-D422-1 (Aggregate Model)
• A pair of Two-wire Sensors or
Three-wire Sensors can be
connected as shown in the
illustration.
Sensor
Sensor
XS2G/XS2H
XS2R-D422-1
XS2G/XS2H
• The XS2R-D422-5 has feed through
connections, thus working as a
connector for the extension cable.
A
B
C
Photoelectric sensor
Photoelectric sensor
XS2W/XS2F/XS2C
XS2R-D423-1 (Bifurcated Model)
XS2W/XS2F/XS2C
XS2R-D423-1
XS2W/XS2F/XS2C
A
B
• Two or Three-wire Sensor signals
can be bifurcated.
C
Proximity sensor
XS2G/XS2H
PLC (A)
PLC (B)
Sensor
XS2R-D424-1 (Daisy Chain Model)
A
B
A
B
A
B
C
C
C
• Two-wire Sensors with contact
output can be connected through a
daisy chain to obtain AND output.
Sensor1
Sensor2
Sensor2
Sensor3
Safety Precautions
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed product ratings.
• Before using the XS2R for Sensors, make sure that the wiring of the Sensors and the internal connections of the XS2R are
correct.
27
XS2
XS2MSensor-embedded Plugs
Ordering Information
DC
Model
AC
Model
No. of
poles
Applicable wire di-
ameter
Mounting method
Pin shape
UL
Embedded with screw
threads
XS2M-D421
XS2M-D422
XS2M-A421
XS2M-A422
UL 2238 certified
(File No. E207683)
4
Solder cup pin
AWG22 to 28
Embedded without
screw threads
Dimensions
(Unit: mm)
Embedded with screw threads
XS2M-D421 (For DC)
XS2M-A421 (For AC)
Mounting Dimensions
Resin
filled
×
M12
1
6.5
45°
45°
O-ring
5 dia.
5 dia.
+0.05
−0
9.45
dia.
10.5 dia.
8 dia. 9.4 dia.
1.2
10
4
0.7
DC
AC
6.7 min.
16
Note: After mounting, anchor the solder cup
pins by injecting resin.
Embedded without screw threads
XS2M-D422 (For DC)
Mounting Dimensions
15.7 min.
Resin
XS2M-A422 (For AC)
O-ring
1.2
5 dia.
5 dia.
9.6 dia.
45°
45°
filled
+0.05
9.45
dia.
−0
10.5 dia.
9.4 dia.
0.7
DC
AC
10.8
16
1.5
6.5
M12 × 1
Note: After mounting, anchor the solder cup
pins by injecting resin.
28
XS2
XS2MPanel-mounting Plugs
Ordering Information
DC
Model
AC
Model
XS2M-A423
XS2M-A424-1
XS2M-A424-2
—
No. of
poles
Applicable wire
diameter
Mounting method
Flange-mounting
Screw-mounting
Pin shape*1
UL
Solder cup pin
DIP pin
AWG22 to 28
—
XS2M-D423
XS2M-D424-1
XS2M-D424-2
XS2M-D524-2
XS2M-D524-4 *2
4
UL 2238 certified
(File No. E207683)
Solder cup pin
Solder cup pin
Solder cup pin
AWG20 to 28
5
Screw-mounting
—
*1. The solder cup pin is for wire mounting, and the DIP pin is for PCB mounting.
Soldering is required for both pins.
Note: 4-pole DC screw-mounting models (XS2M-D424-@) with metal bodies are
also available.
*2. XS2M-D524-4 plugs have a metal body.
Ask your OMRON representative for details.
Dimensions
(Unit: mm)
Flange-mounting
XS2M-D423 (For DC)
XS2M-A423 (For AC)
Panel Cutouts
×
M12
1
10+1
Rubber bushing
2.5 dia.
6.5
0
45°
45°
1.5
5 dia.
5 dia.
Four,
3.2 dia.
3.2 dia.
9.4 dia.
20 14
20 14
10.5 dia.
14 0.1
10
14
20
14
20
2
1
14 0.1
16
0.7
21 min.
DC
AC
Screw-mounting
XS2M-@424-1 For DIP (Resin Body)
XS2M-@424-2 Solder Cup Pins (Resin Body)
Panel Cutout
7+0.2
16+0.3 dia.
0
0
Panel
M16 × 1
M12 × 1
Rubber bushing
2 dia.
1.5
5 dia.
24 min.
16 dia. 20 dia.
Note: The panel thickness is 1 to 4 mm.
PCB-mounting Dimensions
5
3
2.5
17
7
7
Land
1.5
9
3.5
6.8
8.7
6.5
DC
AC
5
27.7
Four,
24 min.
2.2-dia. holes
Solder Cup Pins (Resin Body)
XS2M-D524-2
Solder Cup Pins (Metal Body)
XS2M-D524-4
Panel Cutout
Panel Cutout
7 dia.+0.2
16 dia.+0.3
7 dia.+0.1
16 dia.+0.1
0
0
0
0
3
3
1.5
M16
Seal rubber
×
M16 nut
1
×
M16 1
Seal rubber
M16 nut
×
1
20 dia.
20 dia.
×
M12
1
5 dia.
M12
16 dia.
×
×
M12
1
M12
1
6.5
6.8
8.7
1.5
8.7
1.5
7
17
17
7
6.5
2.5
9
1.5
4.5
18.7
3.5
3.5
27.7
27.7
5.5
5.5
29
XS2
Common Accessories and Tools (Order Separately)
Ordering Information
Connector Covers
Waterproof Covers
Application Example: XS2Z-11
XS2Z-11
M12 male screw
9.4
XS2Z-11
14.9 dia.
M12
×
1
(female
screw)
You can use the Waterproof
Cover when the connector is not
connected to ensure an IP67
degree of protection. When
mounting the Water-resistive
Cover to a Connector, be sure to
apply a torque range between
0.39 and 0.49 N·m to tighten the
Water-resistive Cover.
×
M12
1
XS2Z-22
15.7
9.2
×
M12 1 female screw (thread bracket)
×
1
XS2Z-22
M12
10.6 dia.
14.9 dia.
×
M12
1
Suitable connector
Model
Model
Materials
Mounting portion
XS2G/XS2H/XS2M/XS2R/XS2W/XS5H/
XS5M/XS5W
XS2Z-11
XS2Z-22
M12 male screw
Brass/nickel plated
XS2C/XS2R/XS2F/XS2P/XS2W/XW3B/
XS5F/XS5W/XS5R/XS5P/XW3D
M12 female screw
(thread bracket)
Dust Covers
XS2Z-13
Application Example: XS2Z-13
XS2Z-13
M12 male screw
XS2Z-15/XS2Z-14
M12 female screw (thread bracket)
XS2Z-15
XS2Z-14
The Dust Cover is for dust prevention and does not
ensure IP67 degree of protection.
When mounting the Dust Cover to a Connector, be
sure to press the Dust Cover onto the Connector until
the Connector is fully inserted into the Dust Cover.
Pin block (female pins)
Suitable connector
Model
Model
Materials
Mounting portion
XS2Z-13
XS2Z-14
XS2G/XS2H/XS2M/XS2R
M12 male screw
Pin block
(female pins)
Rubber/black
XS2C/XS2R/XS2F/XS2P/XW3A/XW3B
M12 female screw
(thread bracket)
XS2Z-15
30
XS2
Loosening-preventing C-ring
XS2Z-18
Application Example: XS2Z-18
This C-ring prevents the M12 connector
from becoming loose.
C ring
When you attach the C-ring, press it
securely between the thread bracket and
cover.
Note: Attach C-rings to both the plug and socket.
Model
Materials
Suitable connector
XS2Z-18
POM
XS2F/H/W
Sputter Protective Cover
XS2Z-31
Application Example: XS2Z-31
M12 female screw (thread bracket)
XS2Z-31
The Sputter Protective Cover protects the
connector from weld sputter.
Make sure it covers the entire connector.
Pin block (female contact)
Model
Materials
Suitable connector
XS2Z-31
Silicone rubber/black
XS2F/XS2H/XS2W
Tools
Torque Wrench
XY2F-0004
Crimp Tool
XY2F-0002
Locator
Tool in open position
XY2F-0003
Tool in closed
position
SEL.
NO.
Use the Crimp Tool to crimp a cable core to the XS2U
Crimping Pin used with the XS2C or XS2G Crimping
Connector.
Selector dial
(Set to 8.)
XY2F-0002
Crimp Tool
Locator guide
XY2F-0003 Locator
• The XY2F-0002 Crimp Tool is DMC’s AFM8 (M22520/
2-01).
• Mount the XY2F-0003 Locator (sold separately) to the
locator guide of the Crimp Tool with a screw provided with
the XY2F-0003 Locator.
Pin-block Extraction Tool
XY2F-0001
Use this tool to extract a Pin Block from the covers in order to
make wiring changes or corrections after the cover has been
mounted to the pin block for Connector Assemblies (XS2C/
XS2G, soldering/crimping).
31
XS2
Safety Precautions
Extraction Procedure
Precautions for Correct Use
(1) Disconnecting Components
• The pin block must not be extracted from the same
• Disconnect all components on the cap side from the cover.
Connector more than 3 times, otherwise the proper degree
of protection of the pin block or Connector will not be
maintained.
• Do not use the product in atmospheres or environments that
exceed product ratings.
Pin block Cover
Rubber Cable clamp Cap
bushing
Tightening Cap (Connector Assemblies)
1) Do not use pliers to tighten caps, otherwise the caps may
be damaged. Use your fingers to tighten the Connectors
sufficiently.
(0.39 to 0.49 N·m)
(2) Extracting Pin Block
• Insert the claws of the Tool into the four holes of the cover.
2) If caps are not tightened securely, the Connectors may not
maintain their proper degree of protection (i.e., IP67) or the
caps may become loose due to vibration.
Holes
Connector Connection and Disconnection
• When connecting or disconnecting Connectors, be sure to
hold the Connectors by hand.
• Do not hold the cable when disconnecting Connectors.
• Connectors mating with sockets must be fully inserted into
the mating sections. Tighten the thread bracket carefully so
that the threads will not be damaged.
• Fully tighten thread bracket within a torque range between
0.39 and 0.49 N·m and be sure that the threads of the
opposite parts are hidden by the thread bracket.
• When disconnecting Connectors, be sure to loosen the
thread brackets first. Do not loosen the caps.
Claws
• Make sure that the pin block is outside the Tool.
Tool
• Thread brackets must be loosened in the cutout direction.
Cutout
Pin block
Loosen
Cover
Guide
Cover
• Press the Tool so that the guides of the Tool are in close
contact. Then pull the pin block straight.
Thread
bracket
Guide
Pin block
Degree of Protection
• Do not impose external force continuously on the joints of
pin blocks and covers, otherwise the Connectors may not
keep its proper degree of protection (i.e., IP67).
• The degree of protection of connectors (IP67) is not for a
fully watertight structure. Do not use them underwater.
• Connectors are of resin mold construction. Do not impose
excessive force on them.
Extracting
direction
Setup
• Do not make any cable bends near the base of the Unit.
• Any bends made must have a minimum radius of 40 mm.
32
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2019.6
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2019 All Right Reserved.
相关型号:
XS2F-D422-LC0-A
Circular Connector, 4 Contact(s), Polybutylene Terephthalate, Female, Clamp Terminal, Socket
OMRON
XS2F-D422-LD0-A
Circular Connector, 4 Contact(s), Polybutylene Terephthalate, Female, Clamp Terminal, Socket,
OMRON
XS2F-D522-DG0-A
Circular Connector, 5 Contact(s), Polybutylene Terephthalate, Female, Clamp Terminal, Socket
OMRON
XS2F-D522-GG0-A
Circular Connector, 5 Contact(s), Polybutylene Terephthalate, Female, Clamp Terminal, Socket
OMRON
©2020 ICPDF网 联系我们和版权申明