Y92B-P200 [OMRON]
HEAT SINK 0.43DEGC/W FOR G3PB;型号: | Y92B-P200 |
厂家: | OMRON ELECTRONICS LLC |
描述: | HEAT SINK 0.43DEGC/W FOR G3PB 装置 耐热支撑装置 |
文件: | 总13页 (文件大小:1448K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Solid State Contactors for Heaters
G3PE-Three-phase
CSM_G3PE-Three-phase_DS_E_4_2
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase
Heaters Reduced Installation Work
with DIN Track Mounting.
• RoHS compliant.
• Surge pass protection improved surge dielectric strength
for output currents. (OMRON testing)
• Slim design with 3-phase output and built-in heat sinks.
•
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track
(applicable DIN Track: TR35-15Fe (IEC 60715)).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
• Conforms to UL, CSA, and EN standards (TÜV certification).
Refer to Safety Precautions for All G3PE
Models.
Ordering Information
List of Models
Models with Built-in Heat Sinks
Number of
phases
Insulation
method
Operation
indicator
Rated input
voltage
Zero cross
function
Number of
poles
Type
Applicable load *1
Model
3
G3PE-215B-3N DC12-24
G3PE-215B-2N DC12-24
G3PE-225B-3N DC12-24
G3PE-225B-2N DC12-24
G3PE-235B-3N DC12-24
G3PE-235B-2N DC12-24
G3PE-245B-3N DC12-24
G3PE-245B-2N DC12-24
G3PE-515B-3N DC12-24
G3PE-515B-2N DC12-24
G3PE-525B-3N DC12-24
G3PE-525B-2N DC12-24
G3PE-535B-3N DC12-24
G3PE-535B-2N DC12-24
G3PE-545B-3N DC12-24
G3PE-545B-2N DC12-24
G3PE-215B-3 DC12-24
G3PE-215B-2 DC12-24 *3
G3PE-225B-3 DC12-24
G3PE-225B-2 DC12-24
G3PE-235B-3 DC12-24
G3PE-235B-2 DC12-24
G3PE-245B-3 DC12-24
G3PE-245B-2 DC12-24
G3PE-515B-3 DC12-24
G3PE-515B-2 DC12-24 *3
G3PE-525B-3 DC12-24
G3PE-525B-2 DC12-24
G3PE-535B-3 DC12-24
G3PE-535B-2 DC12-24
G3PE-545B-3 DC12-24
G3PE-545B-2 DC12-24
15 A, 100 to 240 VAC
2
3
25 A, 100 to 240 VAC
35 A, 100 to 240 VAC
45 A, 100 to 240 VAC
15 A, 200 to 480 VAC
25 A, 200 to 480 VAC
35 A, 200 to 480 VAC
45 A, 200 to 480 VAC
15 A, 100 to 240 VAC
25 A, 100 to 240 VAC
35 A, 100 to 240 VAC
45 A, 100 to 240 VAC
15 A, 200 to 480 VAC
25 A, 200 to 480 VAC
35 A, 200 to 480 VAC
45 A, 200 to 480 VAC
2
3
2
3
2
DIN track
mounting *2
3
2
3
2
3
2
3
2
Phototriac
coupler
Three-phase
Yes (yellow)
12 to 24 VDC
Yes
3
2
3
2
3
2
3
2
Screw
mounting
3
2
3
2
3
2
3
2
*1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering
Data on page 5.
*2. The applicable DIN Track is the TR35-15Fe (IEC 60715). For details, refer to the mounting information in the Safety Precautions for All G3PE Models.
*3. DIN Track or Screw mounting.
1
G3PE-Three-phase
Models with Externally Attached Heat Sinks
Number of
phases
Insulation
method
Operation
indicator
Rated input
voltage
Zero cross
function
Number
Model
Type
Applicable load *
of poles
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
G3PE-215B-3H DC12-24
G3PE-215B-2H DC12-24
G3PE-225B-3H DC12-24
G3PE-225B-2H DC12-24
G3PE-235B-3H DC12-24
G3PE-235B-2H DC12-24
G3PE-245B-3H DC12-24
G3PE-245B-2H DC12-24
G3PE-515B-3H DC12-24
G3PE-515B-2H DC12-24
G3PE-525B-3H DC12-24
G3PE-525B-2H DC12-24
G3PE-535B-3H DC12-24
G3PE-535B-2H DC12-24
G3PE-545B-3H DC12-24
G3PE-545B-2H DC12-24
15 A, 100 to 240 VAC
25 A, 100 to 240 VAC
35 A, 100 to 240 VAC
45 A, 100 to 240 VAC
15 A, 200 to 480 VAC
25 A, 200 to 480 VAC
35 A, 200 to 480 VAC
45 A, 200 to 480 VAC
Externally
attached heat
sinks
Phototriac
coupler
Three-phase
Yes (yellow)
12 to 24 VDC
Yes
* The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature. For details, refer to
Load Current vs. Ambient Temperature.
Accessories (Order Separately)
Heat Sink
Heat resistance Rth (s-a) (°C/W)
Model
1.67
1.01
0.63
0.43
0.36
Y92B-P50
Y92B-P100
Y92B-P150
Y92B-P200
Y92B-P250
2
G3PE-Three-phase
Specifications
Certification
UL508, CSA22.2 No.14, and EN60947-4-3
Ratings (at an Ambient Temperature of 25°C)
Operating Circuit (All Models)
ItemModel
Rated operating voltage
Operating voltage range
Same for all models
12 to 24 VDC
9.6 to 30 VDC
Rated input current (impedance) 10 mA max. (24 VDC)
Must-operate voltage
Must-release voltage
Insulation method
9.6 VDC max.
1 VDC min.
Phototriac
Operation indicator
Yellow LED
Main Circuit of Models with Built-in Heat Sinks
Model G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE-
215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B-
Item
3(N)
2(N)
3(N)
2(N)
3(N)
2(N)
3(N)
2(N)
3(N)
2(N)
3(N)
2(N)
3(N)
2(N)
3(N)
2(N)
Rated load voltage
100 to 240 VAC
200 to 480 VAC
Operating voltage
range
75 to 264 VAC
180 to 528 VAC
Rated load current *1
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)
Minimum load current
0.2 A
0.5 A
Inrush current
resistance (peak
value)
150 A
220 A
440 A
(60 Hz, 1 cycle)
220 A
(60 Hz, 1 cycle)
440 A
(60 Hz, 1 cycle)
(60 Hz, 1 cycle) (60 Hz, 1 cycle)
Permissible I2t
(reference value)
121A2s
260A2s
1,260A2s
260A2s
1,260A2s
Applicable load
(resistive load: AC1
class) *2
5.1 kW
(at 200 VAC)
8.6 kW
(at 200 VAC)
12.1 kW
(at 200 VAC)
15.5 kW
(at 200 VAC)
12.5 kW
(at 480 VAC)
20.7 kW
(at 480 VAC)
29.0 kW
(at 480 VAC)
37.4 kW
(at 480 VAC)
*1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering
Data on page 5.
*2. Applicable Load
Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections.
Maximum load capacity = Load current × Load voltage × √3
Example: 15 A × 200 V × √3 = 5,196 W ≅ 5.1 kW
Example: 15 A × 400 V × √3 = 10,392 W ≅ 10.3 kW
Main Circuit of Models with Externally Attached Heat Sinks
Model G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE-
215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B-
Item
3H
2H
3HH
2H
3H
2H
3H
2H
3H
2H
3H
2H
3H
2H
3H
2H
Rated load voltage
100 to 240 VAC
200 to 480 VAC
Operating voltage
range
75 to 264 VAC
180 to 528 VAC
Rated load current *
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)
Minimum load current
0.2 A
0.5 A
Inrush current
resistance (peak
value)
150 A
220 A
440 A
(60 Hz, 1 cycle)
220 A
(60 Hz, 1 cycle)
440 A
(60 Hz, 1 cycle)
(60 Hz, 1 cycle) (60 Hz, 1 cycle)
Permissible I2t
(reference value)
121A2s
260A2s
1,260A2s
260A2s
1,260A2s
Applicable load
(resistive load: AC1
class)
Refer to Engineering Data on page 5.
* The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature.
For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5.
3
G3PE-Three-phase
Characteristics
Models with Built-in Heat Sinks
Model G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE-
215B-
3(N)
215B-
2(N)
225B-
3(N)
225B-
2(N)
235B-
3(N)
235B-
2(N)
245B-
3(N)
245B-
2(N)
515B-
3(N)
515B-
2(N)
525B-
3(N)
525B-
2(N)
535B-
3(N)
535B-
2(N)
545B-
3(N)
545B-
2(N)
Item
Operate time 1/2 of load power source cycle + 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON
1.6 V (RMS) max.
voltage drop
1.8 V (RMS) max.
20 mA max. (at 480 VAC)
Leakage
10 mA max. (at 200 VAC)
current *
Insulation
100 MΩ min. (at 500 VDC)
resistance
Dielectric
2,500 VAC, 50/60 Hz for 1 min
strength
Vibration
resistance
• DIN Track mounting: 10 to 55 to 10 Hz, 0.175-mm single amplitude (0.35-mm double amplitude)
• Screw mounting: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Shock
resistance
294 m/s2 (reverse mounting: 98 m/s2)
Ambient
storage
temperature
−30 to 100°C (with no icing or condensation)
Ambient
operating
temperature
−30 to 80°C (with no icing or condensation)
Ambient
operating
humidity
45% to 85%
Approx. Approx. Approx. Approx. Approx. Approx.
Approx. Approx. Approx. Approx. Approx. Approx.
1.45 kg 1.25 kg 1.65 kg 1.45 kg 2.0 kg 1.65 kg
Weight
Approx. 1.25 kg
Approx. 1.25 kg
1.45 kg 1.25 kg 1.65 kg 1.45 kg 2.0 kg
1.65 kg
* The leakage current of phase S will be approximately √3 times larger if the 2-element model is used.
Models with Externally Attached Heat Sinks
Model G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE- G3PE-
215B-
3H
215B-
2H
225B-
3H
225B-
2H
235B-
3H
235B-
2H
245B-
3H
245B-
2H
515B-
3H
515B-
2H
525B-
3H
525B-
2H
535B-
3H
535B-
2H
545B-
3H
545B-
2H
Item
Operate time 1/2 of load power source cycle + 1 ms max.
Release time 1/2 of load power source cycle + 1 ms max.
Output ON
1.6 V (RMS) max.
voltage drop
1.8 V (RMS) max.
20 mA max. (at 480 VAC)
Leakage
10 mA max. (at 200 VAC)
current *
Insulation
100 MΩ min. (at 500 VDC)
resistance
Dielectric
2,500 VAC, 50/60 Hz for 1 min
strength
Vibration
resistance
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Destruction: 294 m/s2
Shock
resistance
Ambient
storage
temperature
−30 to 100°C (with no icing or condensation)
−30 to 80°C (with no icing or condensation)
Ambient
operating
temperature
Ambient
operating
humidity
45% to 85%
Weight
Approx. 300 g
* The leakage current of phase S will be approximately √3 times larger if the 2-element model is used.
Heat Sinks
Model
Weight
Y92B-P50
Y92B-P100
Y92B-P150
Y92B-P200
Y92B-P250
Approx. 450 g
Approx. 450 g
Approx. 600 g
Approx. 850 g
Approx. 1,200 g
4
G3PE-Three-phase
Engineering Data
Input Voltage vs. Input Impedance and Input Voltage vs. Input Current
G3PE-2@@B-@@
G3PE-5@@B-@@
10
15
14
13
12
11
10
9
Ta = 25°C
9
8
7
6
5
4
3
2
1
Input current
8
Input current
7
6
5
Input impedance
4
Input impedance
3
2
1
0
0
5
10
15
20
25
30
35
0
5
10
15
20
25
30
35
Input voltage (V)
Input voltage (V)
Load Current vs. Ambient Temperature
Models with Built-in Heat Sinks
G3PE-215B-3(N), G3PE-225B-3(N)
G3PE-215B-2(N), G3PE-225B-2(N)
G3PE-515B-3(N), G3PE-525B-3(N)
G3PE-515B-2(N), G3PE-525B-2(N)
G3PE-235B-3(N), G3PE-245B-3(N)
G3PE-235B-2(N), G3PE-245B-2(N)
G3PE-535B-3(N), G3PE-545B-3(N)
G3PE-535B-2(N), G3PE-545B-2(N)
30
50
45
40
35
30
G3PE-245B-3(N)
G3PE-245B-2(N)
G3PE-545B-3(N)
G3PE-545B-2(N)
25
G3PE-225B-3(N)
G3PE-225B-2(N)
G3PE-525B-3(N)
20
15
G3PE-525B-2(N)
G3PE-235B-3(N)
G3PE-235B-2(N)
G3PE-535B-3(N)
G3PE-535B-2(N)
*
G3PE-215B-3(N)
G3PE-215B-2(N)
G3PE-515B-3(N)
G3PE-515B-2(N)
20
18
* The dotted lines in the charts are
the UL derating curves for the
10
7
14
12
10
G3PE-235B-3(N),G3PE-245B-3(N),
G3PE-235B-2(N),G3PE-245B-2(N),
G3PE-535B-3(N),G3PE-545B-3(N),
G3PE-535B-2(N), G3PE-545B-2(N).
0
0
−30 −20
0
20
40
60
80
100
−30 −20
0
20 25 40
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
Models with Externally Attached Heat Sinks
G3PE-215B-3H(-2H)
G3PE-225B-3H(-2H)
G3PE-515B-3H(-2H)
G3PE-525B-3H(-2H)
10
G3PE-235B-3H(-2H)
G3PE-245B-3H(-2H)
G3PE-535B-3H(-2H)
G3PE-545B-3H(-2H)
10
G3PE-235B-3H(-2H)
G3PE-245B-3H(-2H)
G3PE-535B-3H(-2H)
G3PE-545B-3H(-2H)
8
8
G3PE-225B-3H(-2H)
G3PE-525B-3H(-2H)
6
4
6
5
G3PE-215B-3H(-2H)
G3PE-515B-3H(-2H)
4
2
0
2
0
−30 −20
0
2025 40
60
80
100
−30 −20
0
20
40
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
5
G3PE-Three-phase
Inrush Current Resistance: Non-repetitive
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.
G3PE-215B-3(N)(H)
G3PE-215B-2(N)(H)
G3PE-225B-3(N)(H), G3PE-525B-3(N)(H)
G3PE-225B-2(N)(H), G3PE-525B-2(N)(H)
G3PE-515B-3(N)(H),
G3PE-235B-3(N)(H), G3PE-535B-3(N)(H)
G3PE-235B-2(N)(H), G3PE-535B-2(N)(H)
G3PE-245B-3(N)(H), G3PE-545B-3(N)(H)
G3PE-245B-2(N)(H), G3PE-545B-2(N)(H)
G3PE-515B-2(N)(H),
250
200
250
500
200
400
150
100
150
100
300
200
50
0
50
0
100
0
10
30 50 100
300 500 1,000 3,000 5,000
Energized time (ms)
10
30 50 100
300 500 1,000 3,000 5,000
Energized time (ms)
10
30 50 100
300 500 1,000 3,000 5,000
Energized time (ms)
Heat Sink Area vs. Load Current (40°C and 80°C)
G3PE-225B-3H
G3PE-525B-3H
Note: The heat sink area is the combined
area of all surfaces of the heat sink
that radiate heat.
50,000
30,000
50,000
30,000
Ambient temperature
+ 80°C
Ambient temperature
+ 80°C
Ambient temperature
+ 40°C
Ambient temperature
+ 40°C
For the G3PE-525B-3H, when a
current of 18 A flows through the SSR
at 40°C, the graph shows that a heat
sink area of about 2,500 cm2 would
be required. Therefore, if the heat
sink is square, one side of an
10,000
10,000
5,000
3,000
5,000
3,000
Aluminum plate t = 3.0
Aluminum plate t = 3.0
aluminum plate in the heat sink must
be 36 cm or longer (√2,500 (cm2)/2 =
36 cm (rounded to a whole number)).
1,000
1,000
500
300
500
300
100
100
0
10
20
30
40
0
10
20
30
40
Load current (A)
Load current (A)
Models with Externally Attached Heat Sinks
Heat Resistance Rth (Junction/SSR Back
Surface)
Model
Rth (°C/W)
1.05
G3PE-215B-3H
G3PE-225B-3H
G3PE-235B-3H
G3PE-245B-3H
0.57
0.57
0.57
Heat Resistance of Heat Sinks
Model
Rth (°C/W)
1.67
Y92B-P50
Y92B-P100
Y92B-P150
Y92B-P200
Y92B-P250
1.01
0.63
0.43
0.36
Note: If a commercially available heat sink is used, use one that has
a heat resistance equal to or lower than a standard OMRON
Heat Sink.
6
G3PE-Three-phase
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Solid State Relays
Two, 4.6-dia. mounting holes
Models with
Four, 8 dia.
Two, M3.5
DIN Track Mounting
G3PE-215B-3N
G3PE-215B-2N
G3PE-225B-2N
G3PE-515B-3N
84.5
max.
100
max.
90
24 68
Two, R2.3
mounting
holes
G3PE-515B-2N
G3PE-525B-2N
0.5
64
20 20
80 max.
Six, M4
32.2
68
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
35
0.3
64
23.2 max.
19.1
0.3
90
120 max.
Four, 4.5 dia. or M4
Terminal Arrangement/Internal Circuit Diagram
G3PE-215B-3N
G3PE-2@5B-2N
G3PE-515E-3N
G3PE-5@5B-2N
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
Two, 4.6-dia. mounting holes
Four, 8 dia.
Models with
DIN Track Mounting
G3PE-225B-3N
Two, M3.5
G3PE-235B-2N
G3PE-525B-3N
84.5
max.
120
max.
24 68
100 110
G3PE-535B-2N
Two, R2.3
mounting
holes
0.5
64
80 max.
Six, M5 (35-A type)
Six, M4 (25-A type)
20 20
32.2
68
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
35
max.
0.3
64
23.2
19.1
0.3
110
120 max.
Four, 4.5 dia. or M4
Terminal Arrangement/Internal Circuit Diagram
G3PE-235B-2N G3PE-525B-3N
G3PE-225B-3N
G3PE-535B-2N
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
7
G3PE-Three-phase
Two, 4.6-dia. mounting holes
Four, 8 dia.
Models with
DIN Track Mounting
G3PE-235B-3N
Two, M3.5
G3PE-245B-2N
G3PE-535B-3N
G3PE-545B-2N
84.5
max.
140
max.
24 68
120 130
Two, R2.3
mounting
holes
0.5
Six, M5
20 20
32.2
68
64
80 max.
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
35
max.
0.3
64
23.2
19.1
120 max.
0.3
130
Four, 4.5 dia. or M4
Terminal Arrangement/Internal Circuit Diagram
G3PE-235B-3N
G3PE-245B-2N
G3PE-535B-3N
G3PE-545B-2N
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
Models with
DIN Track Mounting
G3PE-245B-3N
Two, 4.6-dia. mounting holes
Four, 8 dia.
Two, M3.5
G3PE-545B-3N
84.5
max.
140
max.
24 68
120 130
Two, R2.3
mounting
holes
0.5
Six, M5
64
20 20
32.2
68
80 max.
110 max.
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
35
max.
0.3
64
23.2
19.1
120 max.
0.3
130
Four, 4.5 dia. or M4
Terminal Arrangement/Internal Circuit Diagram
G3PE245B-3N G3PE-545B-3N
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
8
G3PE-Three-phase
Models with Screw Mounting
G3PE-215B-2
4.6 dia.
50
G3PE-515B-2
84.5
max.
100
90
24
68
max.
Two, M3.5
Six, M4
0.5
80 max.
4.6 × 5.6
elliptical hole
20 20
32.2
Note: With terminal cover.
68
Note: Without terminal cover.
DIN Track or screw mounting
Mounting Holes
Two, 4.5 dia. or M4
35
max.
23.2
19.1
0.3
90
55 max.
Terminal Arrangement/Internal Circuit Diagram
G3PE-215B-2 G3PE-515B-2
0.3
50
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
Models with Screw Mounting
G3PE-215B-3
Four, R2.5
5
G3PE-225B-2
G3PE-515B-3
G3PE-525B-2
84.5
max.
80.5
24
68
60
Two, M3.5
Six, M4
0.5
80 max.
90
20 20
32.2
100
110.5 max.
68
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
35
max.
Four, 4.5 dia. or M4
23.2
19.1
For screw mounting only
0.3
60
70 max.
0.3
100
Terminal Arrangement/Internal Circuit Diagram
G3PE-225B-2
G3PE-215B-3
G3PE-515B-3
G3PE-525B-2
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
9
G3PE-Three-phase
5
Models with
Four, R2.5
Screw Mounting
G3PE-225B-3
G3PE-235B-2
G3PE-525B-3
G3PE-535B-2
84.5
max.
110.5
max.
24
68
90
Two, M3.5
Six, M5
(G3PE-@35B-2)
Six, M4
0.5
80 max.
90
20 20
32.2
100
(G3PE-@25B-3)
110.5 max.
68
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
Four, 4.5 dia. or M4
35
max.
For screw mounting only
23.2
19.1
0.3
90
70 max.
0.3
100
Terminal Arrangement/Internal Circuit Diagram
G3PE-235B-2
G3PE-225B-3
G3PE-525B-3
G3PE-535B-2
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
Models with
5
Four, R2.5
Screw Mounting
G3PE-235B-3
G3PE-245B-2
G3PE-535B-3
G3PE-545B-2
84.5
max.
130.5
max.
24 68
90
Two, M3.5
Six, M5
0.5
80 max.
110
20 20
32.2
120
68
130.5 max.
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
Four, 4.5 dia. or M4
35
max.
23.2
19.1
For screw mounting only
70 max.
0.3
90
0.3
120
Terminal Arrangement/Internal Circuit Diagram
G3PE-245B-2
G3PE-235B-3
G3PE-535B-3
G3PE-545B-2
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
10
G3PE-Three-phase
Models with Screw Mounting
G3PE-245B-3
5
Four, R2.5
G3PE-545B-3
84.5
max.
190.5
max.
24 68
150
Two, M3.5
Six, M5
0.5
80 max.
20 20
32.2
110
120
130.5 max.
68
Note: Without terminal cover.
Note: With terminal cover.
Mounting Holes
35
max.
Four, 4.5 dia. or M4
For screw mounting only
23.2
19.1
70 max.
0.3
150
Terminal Arrangement/Internal Circuit Diagram
G3PE-245B-3 G3PE-545B-3
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
0.3
120
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
Models with Externally Attached Heat Sinks
Four, 8 dia.
Four, 4.5 dia.
9
G3PE-215B-3H
G3PE-215B-2H
G3PE-225B-3H
G3PE-225B-2H
G3PE-235B-3H
G3PE-235B-2H
G3PE-245B-3H
G3PE-245B-2H
G3PE-515B-3H
G3PE-515B-2H
G3PE-525B-3H
G3PE-525B-2H
G3PE-535B-3H
G3PE-535B-2H
G3PE-545B-3H
G3PE-545B-2H
8 dia.
4.5 dia.
84.5
24 68
80
max.
Two, M3.5
Six, M4
(G3PE-@15B-@H/-@25B-@H)
Six, M5
(G3PE-@35B-@H/-@45B-@H)
0.5
80 max.
20 20
32.2
Note: With terminal cover.
68
Note: Without terminal cover.
Mounting Holes
Four, 4.5 dia. or M4
35
max.
23.2
19.1
0.3
68
0.3
68
Terminal Arrangement/Internal Circuit Diagram
G3PE-2@5B-2H G3PE-5@5B-3H
G3PE-2@5B-3H
G3PE-5@5B-2H
(+)
(+)
(+)
(+)
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
L1/R
L2/S
L3/T
A1
A1
A1
A1
A2
A2
A2
A2
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
T1/U
T2/V
T3/W
(−)
(−)
(−)
(−)
11
G3PE-Three-phase
Accessories (Order Separately)
Heat Sink
Heat Sink
Y92B-P100
For G3PE-215B-3H,
G3PE-225B-2H,
G3PE-515B-3H, and
G3PE-525B-2H
Y92B-P50 (Mounts to DIN Track.)
For G3PE-215B-2H and
G3PE-515B-2H
Four, M4
Mounting Holes
Mounting Holes
4.6 dia.
100
50
Four, 4.5 dia. or M4
Two, 4.5 dia. or M4
5
80.5
max.
0.3
60
68
60
80.5
max.
100
max.
68
90
0.3
90
4.6 × 5.6
elliptical
hole
0.3
100
Four,
R2.5
68
110.5 max.
0.3
50
68
80 max.
70 max.
55 max.
Heat Sink
Y92B-P150
Heat Sink
Y92B-P200
Heat Sink
Y92B-P250
For G3PE-225B-3H,
G3PE-235B-2H,
For G3PE-235B-3H,
G3PE-245B-2H,
For G3PE-245B-3H and
G3PE-545B-3H
G3PE-525B-3H, and
G3PE-535B-2H
G3PE-535B-3H, and
G3PE-545B-2H
120
Four, M4
120
100
Four, M4
5
5
5
M4-D10
Four, M4
110.5
max.
130.5
90
68
90
68
max.
190.5
max.
68 47.6
150
Four,
68
Four,
R2.5
R2.5
68
120
M4-D10
110.5 max.
130.5 max.
Four,
R2.5
68
120
130.5 max.
70 max.
70 max.
70 max.
Mounting Holes
Mounting Holes
Mounting Holes
Four, 4.5 dia. or M4
Four, 4.5 dia. or M4
Four, 4.5 dia. or M4
0.3
90
0.3
90
0.3
150
0.3
100
0.3
120
0.3
120
12
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
相关型号:
Y92B-P250
Solid State Relays G3NAWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92B-P250NF
Solid State Relays G3NAWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92B-P50
HEAT SINK 1.67DEGC/W FOR G3PBWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92B-S08N
Solid State RelayWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92C-30
This Compact Cam Positioner, Popular for Its Ease-of-use, Now Comes with Even Better Functions.Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92E-A34
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92E-B12
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92E-B18-2
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92E-B30
Inductive SensorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92E-B30-2
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92E-B8
Analog CircuitWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
Y92E-C1R6
Miniature Square Inductive Proximity SensorWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON
©2020 ICPDF网 联系我们和版权申明