Z-15GA55 [OMRON]

Snap Acting/Limit Switch,;
Z-15GA55
型号: Z-15GA55
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch,

文件: 总28页 (文件大小:7080K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General-purpose Basic Switch  
Z
CSM_Z_DS_E_4_4  
Best-selling Basic Switch Boasting  
High Precision and Wide Variety  
• A large switching capacity of 15 A with high repeat accuracy.  
• A wide range of variations in contact form for your selection: basic,  
split-contact, maintained-contact, and adjustable contact gap types.  
• A series of standard models for micro loads is available.  
• A series of molded terminal-type models incorporating safety  
terminal protective cover is available.  
Be sure to read Safety Precautions on page 26 and Safety Precautions  
for All Basic Switches.  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
Model Number Structure  
Configuration  
Refer to page 3.  
Refer to page 5.  
Basic models  
General-purpose  
Drip-proof  
Without terminal protective cover  
Refer to page 5.  
Refer to page 2.  
Refer to page 4.  
Refer to page 4.  
With terminal protective cover  
Molded terminal  
Split-contact models  
General-purpose  
General-purpose  
Maintained-contact models  
Basic Models  
Split-contact Models  
This type is identical in construction to the general-purpose basic  
switch except that it has two pairs of simultaneous acting contacts  
by splitting moving contacts.  
Since the moving contacts are connected to a common terminal,  
either parallel or series connection is possible.  
Highly reliable micro load switching is ensured if the model is used  
as a twin-contact switch.  
General-purpose  
A variety of actuators is available for a wide range of application.  
The contact mechanism of models for micro loads is a crossbar  
type with gold-alloy contacts, which ensures highly reliable  
operations for micro loads.  
Contact Gap:  
H2: 0.20 mm (extra-high-sensitivity)  
H: 0.25 mm (high-sensitivity, micro voltage current load)  
G: 0.5 mm (standard)  
E: 1.8 mm (high-capacity)  
Maintained-contact Models  
The maintained-contact type has a reset button at the bottom of the  
switch case, in addition to the pushbutton (plunger) located on the  
opposite side of the reset button. Use these buttons alternately.  
Since the Switch has greater pretravel than overtravel, it is suitable  
for use in reversible control circuits, manual reset circuits, safety  
limit circuits, and other circuits which are not preferable for  
automatic resetting. (For further details, refer to individual  
datasheets.)  
Drip-proof  
These Switches use a rubber boot on the actuator and adhesive fill  
between the case and cover to increase resistance to drips.  
Models with drip-proof terminal protective covers and molded  
terminals with resin filling are also available.  
1
Z
Model Number Legend  
Basic Models  
Standard Models (Drip-proof Type/Molded Terminals)  
Z-@@@@-@  
Z-@55-M@@ @M  
(1)(2)(3)(4) (5)  
(1)  
(2)(3) (4)  
(1) Ratings  
(1) Drip-proof Type  
(2) Lead Outlets  
None : VSF  
01  
15  
: 0.1 A (micro load)  
: 15 A  
(2) Contact Gap  
19  
: VCT  
H2  
H
: 0.20 (extra-high-sensitivity)  
: 0.25 mm (high-sensitivity,  
micro load)  
: 0.5 mm (standard)  
: 1.8 mm (high-capacity)  
(3) Directions of Lead  
Outlets (See following  
diagrams.)  
L Type  
D Type  
R Type  
G
E
L
: Left  
(3) Actuator  
R
D
: Right  
: Descending  
None : Pin plunger  
(4) Length of Lead  
Outlets  
S
D
K
K3  
Q3  
Q
: Slim spring plunger  
: Short spring plunger  
: Spring plunger (medium OP)  
: Spring plunger (high OP)  
: Panel mount plunger (low OP)  
: Panel mount plunger (medium  
OP)  
1
3
: 1 m  
: 3 m  
Split-contact Models  
Maintained-contact Models  
Q8  
Q22  
Q21  
: Panel mount plunger (high OP)  
: Panel mount roller plunger  
: Panel mount cross roller  
plunger  
Z-10F@Y-B  
Z-15-E@R  
(1)(2)(3)(4) (5)  
(1) (2)(3)(4)  
(1) Ratings  
(1) Ratings  
L
L2  
W21  
W
W3  
W32  
W4  
W44  
W78  
: Leaf spring (high OF)  
: Roller leaf spring  
: Short hinge lever  
: Hinge lever (low OF)  
: Hinge lever (medium OF)  
: Hinge lever (high OF)  
: Low-force hinge lever  
: Long hinge lever  
: Low-force wire hinge lever  
(low OF)  
: Low-force wire hinge lever  
(high OF)  
: Short hinge roller lever  
: Hinge roller lever  
: Hinge roller lever (large roller)  
: Short hinge cross roller lever  
: Hinge cross roller lever  
10  
: 10 A (split-contact models)  
15  
: 15 A  
(2) Contact Gap  
F
(3) Actuator  
None : Pin plunger  
S
D
Q
Q22  
W
(2) Contact Gap  
E
(3) Actuator  
None : Pin plunger  
S
W
: 1 mm (high-capacity)  
: 1.8 mm (high capacity)  
: Slim spring plunger  
: Slim spring plunger  
: Hinge lever  
: Short spring plunger  
: Panel mount plunger  
: Panel mount roller plunger  
: Hinge lever  
: Short hinge roller lever  
: Hinge roller lever  
: Reverse short hinge roller  
lever  
(4) Structure  
R
: Maintained-contact models  
W52  
W22  
W2  
M22  
W22  
W2  
W25  
W49  
W54  
(4) Construction  
Y
: Split-contact models  
(5) Terminals  
W2277 : Unidirectional short hinge  
roller lever (low OF)  
B
: Screw terminal  
(with toothed washer)  
M
: Reverse hinge lever  
: Reverse short hinge roller  
lever  
M22  
M2  
NJ  
NJS  
: Reverse hinge roller lever  
: Flexible rod (high OF)  
: Flexible rod (low OF)  
(4) Degree of Protection  
None : General-purpose  
55  
: Drip-proof  
(not include the terminals)  
: Drip-proof  
A55  
(including the terminals)  
(5) Terminals  
None : Solder terminal  
B
: Screw terminal  
(with toothed washer)  
B5V  
: Screw terminal with terminal  
cover (for Z-15G@A55 only)  
Note: For combinations of models, Ordering  
Information on page 3 to 6.  
2
Z
Ordering Information  
Main Unit  
Basic Models (General-purpose)  
Extra-high  
sensitivity  
Classification  
Standard  
High-sensitivity  
High-capacity  
Micro load  
Actuator  
Contact gap  
G (0.5 mm)  
Model  
H (0.25 mm)  
Model  
H2 (0.20 mm)  
Model  
E (1.8 mm)  
Model  
H (0.25 mm)  
Model  
Terminal *1  
Pin plunger  
Z-15G  
Z-15H  
Z-15H2  
Z-15E  
Z-01H  
Z-15G-B  
Z-15H-B  
Z-15HS  
Z-15H2-B  
Z-15E-B  
Z-01H-B  
Z-01HS  
Z-15GS  
Slim spring plunger  
---  
---  
---  
Z-15GS-B  
Z-15GD  
Z-15HS-B  
Z-15HD  
Z-01HS-B  
Z-01HD  
Z-15ED  
Short spring  
plunger  
Z-15GD-B  
Z-15GQ3  
Z-15HD-B  
Z-15ED-B  
Z-01HD-B  
Low  
OP  
---  
---  
---  
Panel mount  
plunger  
Z-15GQ3-B  
Z-15GQ  
Z-15HQ  
Z-15EQ  
Z-01HQ  
Medium  
OP  
---  
Z-15GQ-B  
Z-15GQ8  
Z-15HQ-B  
Z-15EQ-B  
Z-01HQ-B  
High  
OP  
---  
---  
---  
---  
---  
---  
---  
---  
Z-15GQ8-B  
Z-15GQ22  
Z-15GQ22-B  
Z-15GQ21  
Z-15GQ21-B  
Z-15GL  
Z-15HQ22  
Z-15HQ22-B  
Z-15HQ21  
Z-15EQ22  
Z-15EQ22-B  
Z-15EQ21  
Panel mount roller  
plunger  
---  
---  
---  
---  
---  
Panel mount cross  
roller plunger  
Z-15HQ21-B  
Z-15EQ21-B  
Leaf spring  
---  
---  
---  
---  
---  
---  
Z-15GL-B  
Z-15GL2  
Roller leaf spring  
Short hinge lever  
Z-15GL2-B  
Z-15GW21  
Z-15GW21-B  
Z-15GW  
Z-15HW  
Low  
OP  
Z-15GW-B  
Z-15GW3  
Z-15GW3-B  
Z-15GW32  
Z-15GW32-B  
Z-15GW4  
Z-15GW4-B  
Z-15HW-B  
Hinge lever  
Medium  
OP  
---  
---  
---  
---  
High  
OP  
Z-15HW24  
Z-15HW24-B  
Z-15HW78  
Low-force hinge  
lever  
---  
---  
---  
---  
---  
---  
Low  
OP  
Low-  
Z-15HW78-B  
Z-15HW52  
forcewire  
hinge  
---  
High  
OP  
lever  
Z-15HW52-B  
Z-15HW22  
Z-15GW22  
Z-15GW22-B  
Z-15GW49  
Z-15EW22  
Z-01HW22  
Short hinge roller  
lever  
---  
---  
Z-15HW22-B  
Z-15EW22-B  
Z-01HW22-B  
Short hinge cross  
roller lever  
---  
---  
---  
---  
---  
---  
---  
---  
---  
Z-15GW49-B  
Z-15GW2  
Z-15HW2  
Stan-  
dard  
Hinge roller  
lever  
Z-15GW2-B  
Z-15GW25  
Z-15HW2-B  
---  
Large  
roller  
---  
---  
Z-15GW25-B  
Z-15GW54  
Hinge cross roller  
lever  
---  
---  
---  
---  
---  
Z-15GW54-B  
Z-15GW2277  
Unidirectional  
short hinge  
roller lever  
Parallel  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
Z-15GW2277-B  
Z-15GM  
Z-15GM-B  
Z-15GM22  
Reverse hinge lever *2  
Reverse short  
hinge roller lever  
Reverse hinge  
*2  
Z-15GM22-B  
Z-15GM2  
roller lever *2  
Z-15GM2-B  
*1.  
: Solder terminal  
: Screw terminal  
*2. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating  
the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed.  
3
Z
Minimum Order Lot  
The following models are available at the minimum order lot specified below.  
Orders must be placed per lot.  
Classification  
Minimum  
order lot (pcs)  
Standard  
Z-15GD-B  
High-sensitivity  
---  
Actuator  
Short spring plunger  
Z-15GQ  
Z-15GQ-B  
Z-15GQ8-B  
---  
---  
Panel mount plunger  
Z-15GQ22  
Z-15GQ22-B  
Panel mount roller plunger  
Panel mount cross roller  
plunger  
Short hinge lever  
Z-15GQ21-B  
---  
---  
---  
Z-15GW21-B  
Z-15GW  
Z-15GW-B  
Hinge lever  
10  
Z-15GW4-B  
---  
Z-15HW24-B  
Z-15HW78-B  
Low-force hinge lever  
Low-force hinge wire lever  
Z-15GW22  
Z-15GW22-B  
Short hinge roller lever  
Hinge roller lever  
---  
---  
Z-15GW2  
Z-15GW2-B  
Reverse short hinge roller  
lever  
Z-15GM22-B  
Z-15GM2-B  
---  
---  
Reverse hinge roller lever  
Split-contact Models  
Maintained-contact Models  
Actuator  
Contact gap  
Terminal  
F (1.0 mm)  
Model  
Z-15ER  
Actuator  
*
1
Model  
---  
Pin plunger  
Pin plunger  
Z-10FY-B  
---  
Z-15ESR  
Z-15EWR  
Slim spring plunger  
Hinge lever  
Slim spring plunger  
Short spring plunger  
Z-10FSY-B  
---  
Z-10FDY-B  
---  
Panel mount plunger  
Z-10FQY-B  
---  
Z-10FQ22Y-B  
---  
Panel mount roller  
plunger  
Hinge lever  
Z-10FWY-B  
---  
Short hinge roller  
lever  
Z-10FW22Y-B  
---  
Hinge roller lever  
Z-10FW2Y-B  
---  
Reverse short hinge  
roller lever *2  
Z-10FM22Y-B  
*1.  
: Solder terminal  
: Screw terminal  
*2. The pin plungers of reverse-type models are continuously pressed by the  
actuator levers with compression coil springs and the pin plungers are freed  
by operating the levers. Reverse-type models are highly vibration- and  
shock-resistive because the pin plungers are normally pressed.  
4
Z
Standard, Microload  
Basic Models (Drip-proof Models  
)
Classification  
Standard  
Micro load  
Contact gap  
G (0.5 mm)  
H (0.25 mm)  
Drip-proof terminal  
protective cover  
Not provided  
Provided  
Not provided  
Terminal  
*1  
Model  
Model  
---  
Model  
Z-01H55  
Actuator  
Z-15G55  
Pin plunger  
Z-15G55-B  
Z-15GD55  
Z-15GD55-B  
Z-15GK55  
Z-15GK55-B  
Z-15GK355  
Z-15GK355-B  
Z-15GQ55  
Z-15GA55-B5V  
Z-01H55-B  
Z-01HD55  
Z-01HD55-B  
Short spring plunger  
Spring plunger  
---  
---  
Low  
OP  
---  
---  
---  
---  
Z-15GK3A55-B5V  
---  
High  
OP  
Panel mount plunger  
Z-15GQ55-B  
Z-15GQ2255  
Z-15GQ2255-B  
Z-15GQA55-B5V  
---  
Panel mount roller  
plunger  
---  
Z-15GQ22A55-B5V  
---  
---  
Panel mount cross  
roller plunger  
---  
---  
---  
---  
---  
---  
Z-15GQ2155-B  
Z-15GL55  
Z-15GQ21A55-B5V  
Leaf spring  
---  
---  
---  
Z-15GL55-B  
Z-15GL255  
Roller leaf spring  
Short hinge lever  
Long hinge lever  
Hinge lever  
Z-15GL255-B  
Z-15GW2155  
Z-15GW2155-B  
Z-15GW4455  
Z-15GW4455-B  
Z-15GW55  
---  
Z-15GW44A55-B5V  
---  
Z-15GW55-B  
Z-15GW2255  
Z-15GW2255-B  
Z-15GWA55-B5V  
---  
Z-01HW2255  
Short hinge roller lever  
Z-15GW22A55-B5V  
Z-01HW2255-B  
Z-15GW255  
Z-15GW255-B  
Z-15GW227755  
---  
Hinge roller lever  
---  
---  
Z-15GW2A55-B5V  
---  
Unidirectional short  
hinge roller lever  
Z-15GW227755-B  
Z-15GM55  
Z-15GW2277A55-B5V  
Reverse hinge lever  
Reverse short hinge  
*2  
---  
---  
---  
---  
---  
---  
Z-15GM55-B  
Z-15GM2255  
Z-15GM2255-B  
Z-15GM255  
roller lever  
*2  
Reverse hinge roller  
lever  
*2  
Z-15GM255-B  
Z-15GNJ55  
Flexible rod (coil spring)  
*3  
---  
---  
Z-15GNJ55-B  
*1.  
: Solder terminal  
: Screw terminal  
*2. The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating  
the levers.  
*3. The tip is made of resin.  
Classification  
Contact gap  
Standard  
G (0.5 mm)  
Minimum order  
lot (pcs)  
Minimum Order Lot  
Actuator  
The following models are available at the minimum order lot specified  
below.  
Orders must be placed per lot.  
Short spring plunger  
Spring plunger  
Z-15GD55-B  
Z-15GK55-B  
Z-15GW4455-B  
Z-15GW55  
Hinge lever  
Z-15GW55-B  
Z-15GW2255  
Z-15GW2255-B  
Z-15GW255-B  
Z-15GNJ55-B  
10  
Short hinge roller lever  
Hinge roller lever  
Flexible rod (coil spring)  
5
Z
Basic Models (Drip-proof Models  
)
Minimum Order Lot  
High-sensitivity  
The following models are available at the minimum order lot specified  
below.  
Orders must be placed per lot.  
Classification  
Contact gap  
Drip-proof terminal protective cover  
High-sensitivity  
H (0.25 mm)  
Not provided  
Model  
Classification High-sensitivity  
Minimumorder  
lot (pcs)  
Actuator  
Terminal *  
Actuator  
Contact gap  
H (0.25 mm)  
Z-15HNJS55  
Flexible rod (steel wire)  
Z-15HNJS55-B  
10  
Flexible rod  
(steel wire)  
Z-15HNJS55-B  
*
: Solder terminal  
: Screw terminal  
Specifications  
Ratings (Basic, Split-contact and Maintained contact Models)  
Z-15 (Except Micro Load and Flexible Rod Models)  
Z-01H  
Item  
Non-inductive load (A)  
Resistive load Lamp load  
Inductive load (A)  
Inductive load Motor load  
Resistive load (A)  
NC NO  
Rated voltage  
Contact Rated  
gap voltage  
125 VAC  
8 VDC  
14 VDC  
30 VDC  
0.1  
NC NO  
15 (10) *  
15 (10) *  
10  
NC  
NO  
NC NO  
15 (10) *  
15 (10) *  
6
NC  
NO  
0.1  
0.1  
0.1  
125 VAC  
250 VAC  
500 VAC *  
3
2.5  
1.5  
1.5  
1.25  
0.75  
5
3
1.5  
2.5  
1.5  
0.75  
G, H,  
H2, E  
8 VDC  
15  
15  
6
0.5  
0.25  
3
3
3
0.5  
0.25  
1.5  
1.5  
1.5  
0.5  
0.25  
15  
10  
5
0.05  
0.03  
5
5
5
0.05  
0.03  
2.5  
2.5  
2.5  
0.05  
0.03  
14 VDC  
30 VDC  
125 VDC  
250 VDC  
Note: 1. The above current ratings are the values  
of the steady-state current.  
G
2. Inductive load has a power factor of 0.4  
min. (AC) and a time constant of 7 ms  
max. (DC).  
3. Lamp load has an inrush current of 10  
times the steady-state current.  
4. Motor load has an inrush current of 6  
times the steady-state current.  
5. The normally closed and normally open  
ratings of reverse hinge lever models are  
opposite to each other.  
6. The AC ratings of molded terminals are  
125 and 250 V only.  
7. The ratings values apply under the  
following test conditions:  
8 VDC  
15  
15  
2
0.4  
0.2  
3
3
2
0.4  
0.2  
1.5  
1.5  
1.4  
0.4  
0.2  
15  
10  
1
0.03  
0.02  
5
5
1
0.03  
0.02  
2.5  
2.5  
1
0.03  
0.02  
14 VDC  
H, H2 30 VDC  
125 VDC  
250 VDC  
8 VDC  
14 VDC  
30 VDC  
125 VDC  
250 VDC  
15  
15  
15  
0.75  
0.3  
3
3
3
0.75  
0.3  
1.5  
1.5  
1.5  
0.75  
0.3  
15  
15  
10  
0.4  
0.2  
5
5
5
0.4  
0.2  
2.5  
2.5  
2.5  
0.4  
0.2  
E
(1) Ambient temperature: 20 2°C  
(2) Ambient humidity: 65 5%RH  
(3) Operating frequency: 20 operations/min  
* Figures in parentheses are for the Z-15HW52, Z-15HW78(-B) and Z-15H2(-B) models, the AC ratings of  
these models are 125 and 250 V only.  
Z-15 (Flexible Rod Models)  
Non-inductive load (A)  
Resistive load Lamp load  
NC NO  
Inductive load (A)  
Inductive load Motor load  
NC NO  
Rated voltage  
Use the switch within the operating  
range.  
NC  
NO  
NC  
NO  
125 VAC  
250 VAC  
15  
15  
2
1
1
0.5  
7
5
2.5  
1.5  
2
1
5 mW  
800 mW  
0.16 mA  
26 mA  
30  
24  
8 VDC  
15  
15  
2
0.4  
0.2  
2
2
2
0.4  
0.2  
1
1
1
0.4  
0.2  
7
7
1
0.03  
0.02  
3
3
1
0.03  
0.02  
1.5  
1.5  
0.5  
0.03  
0.02  
Standard  
load area  
Z-15H, H2  
Z-15G  
Z-15E  
Z-10FY  
Z-15ER  
14 VDC  
30 VDC  
125 VDC  
250 VDC  
Micro load area  
Z-01H  
Z-10F  
12  
Item  
Non-inductive load (A)  
Resistive load Lamp load  
Inductive load (A)  
Unusable  
Inductive load  
Motor load  
range  
Contact  
gap  
Rated  
voltage  
5
0
NC NO  
NC  
NO  
NC NO  
NC  
NO  
1 mA  
100 mA 160 mA  
125 VAC  
250 VAC  
10  
10  
4
2.5  
2
1.5  
6
6
5
3
2.5  
1.5  
0.1  
1
10  
100  
1,000  
Series  
connec-  
tion  
Current (mA)  
30 VDC  
125 VDC  
250 VDC  
10  
1
0.6  
4
1
0.6  
2
1
0.6  
6
0.1  
0.05  
6
0.1  
0.05  
3
0.1  
0.05  
Z-01H  
Z-15@, Z-10FY  
Minimum  
applicable  
load  
125 VAC  
250 VAC  
6
6
3
2.5  
1.5  
1.25  
4
4
4
2
2
1
5 VDC 1 mA 5 VDC 160 mA  
Parallel  
connec-  
tion  
30 VDC  
125 VDC  
250 VDC  
6
0.6  
0.3  
4
0.6  
0.3  
2
0.6  
0.3  
4
0.1  
0.05  
6
0.1  
0.05  
3
0.1  
0.05  
6
Z
Certified Standard Ratings  
Ask your OMRON representative for information on certified models.  
UL/CSA (General ratings only)  
TÜV (EN61058-1)  
Rated  
Model  
Rated  
Z-15H@  
Z-15G@  
Z-01H@  
Model  
Z-15  
Z-10F  
Z-01H  
voltage  
voltage  
125 VAC  
250 VAC  
480 VAC  
30 VDC  
250 VAC  
125 VAC  
30 VDC  
15 A  
---  
---  
15 A  
---  
---  
---  
0.1 A  
0.1 A  
15A 1/8HP  
15A 1/4HP  
15A  
---  
0.5A  
6A 1/10HP  
6A 1/8HP  
6A  
---  
0.6A  
0.1A  
---  
---  
0.1A  
---  
---  
CCC (GB14048.5)  
125 VDC  
250 VDC  
Rated  
Model  
0.25A  
0.3A  
Z-15H@  
Z-15G@  
Z-01H@  
voltage  
250 VAC  
125 VAC  
30 VDC  
15 A  
---  
---  
15 A  
---  
---  
---  
0.1 A  
0.1 A  
Characteristics  
Classifica-  
Z-15 (except micro  
tion load and flexible rod)  
Item  
Z-01H  
Z-15 (flexible rod)  
Z-10F  
Z-15H2  
Operating speed  
0.01 mm to 1 m/s *1  
1 mm to 1 m/s  
120 operations/min  
0.1 mm to 1 m/s *1  
240 operations/min  
0.01 mm to 1 m/s  
240 operations/min  
Mechanical 240 operations/min  
Operating  
frequency  
Electrical  
20 operations/min  
Insulation resistance  
Contact resistance  
100 MΩ min. (at 500 VDC)  
15 mΩ  
max. (initial value) 50 m  
Ω
max. (initial value) 15 mΩ max. (initial value)  
25 mΩ max. (initial value) 15 mΩ max. (initial value)  
Between contacts of same polarity  
Between contacts of same polarity  
Contact gap G: 1,000 VAC, 50/60 Hz for 1  
min  
Between contacts of same  
polarity  
Contact gap F: 1,500 VAC,  
Between contacts of  
same polarity  
600VAC, 50/60Hz for  
Contact gap G: 1,000 VAC, 50/60 Hz for 1 min  
Contact gap H: 600 VAC, 50/60 Hz for 1 min  
Contact gap E: 1,500 VAC, 50/60 Hz for 1 min  
Dielectric strength  
Contact gap H: 600 VAC, 50/60 Hz for 1 min 50/60 Hz for 1 min  
1min  
Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min  
10 to 20 Hz, 1.5-mm double  
Vibration  
resistance  
Malfunction 10 to 55 Hz, 1.5-mm double amplitude *5  
10 to 55 Hz, 1.5-mm double amplitude *5  
amplitude *5  
Destruction 1,000 m/s2 max.  
Malfunction 300 m/s2 max. *2 *5  
Shock  
resistance  
50 m/s2 max. *5  
300 m/s2 max. *3 *5  
100 m/s2 max.  
Contact gap G, H: 20,000,000 operations min.  
Contact gap E: 300,000 operations  
Contact gap G, H: 500,000 operations min.  
Contact gap E: 100,000 operations min.  
500,000 operations  
min. *1  
100,000 operations  
min.  
20,000,000operations  
min.  
500,000 operations  
min.  
Mechanical  
Electrical  
1,000,000 operations min.  
Durability  
100,000 operations min.  
General-purpose IP00  
Drip-proof Equivalent to IP62 (except terminals)  
Degree of  
protection  
Degree of protection  
against electric shock  
Proof tracking index  
(PTI)  
Class I  
175  
General-purpose 25°C to 80°C (with no icing)  
Drip-proof 15°C to 80°C (with no icing)  
General-purpose 35% to 85%RH  
Ambient operat-  
ing temperature  
Ambient operat-  
ing humidity  
Drip-proof 35% to 95%RH  
Weight  
Approx. 22 to 58 g  
Approx. 42 to 48 g  
Approx. 34 to 61 g  
Approx. 22 g  
*1. The values are for the plunger models. (For the lever models, the values are at the plunger section.) (Consult your OMRON representative for other models.)  
*2. The values are for the Z-15G pin plunger.  
*3. The values are for the Z-10FY-B.  
*4. The values are for the pin plunger. The durability for models other than the pin plunger is 10,000,000 min.  
*5. Malfunction: 1 ms max.  
Contacts Specification  
Item  
Classification  
Z-15  
Rivet  
Z-01H  
Single crossbar  
Gold alloy  
Z-10F  
Rivet  
Shape  
Contacts  
Material  
NC  
Silver  
Silver  
30 A max.  
15 A max.  
0.1 A max.  
0.1 A max.  
40 A max.  
20 A max.  
Inrush current  
NO  
Engineering Data  
Mechanical Durability (Z-15G)  
Electrical Durability (Z-15G)  
10,000  
5,000  
Ambient temperature: 20 2°C  
Ambient temperature: 20 2°C  
Ambient humidity: 65 5%RH  
3,000  
Ambient humidity: 65 5%RH  
5,000  
3,000  
Without load  
Operating frequency: 240 operations/min  
Operating frequency: 20 operations/min.  
125 VAC cos dia. = 1  
125 VAC cos dia. = 0.4  
1,000  
500  
300  
250 VAC cos dia. = 1  
250 VAC  
cos dia. = 0.4  
1,000  
100  
500  
300  
50  
30  
500 VAC cos dia. = 1  
500 VAC cos dia. = 0.4  
100  
10  
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8  
Overtravel (mm)  
0
2
4
6
8
10 12 14 16  
Switching Current (A)  
7
Z
Structure  
Basic Models  
Split-contact Models  
Contact Form (SPDT)  
Contact Form  
NC  
COM  
NC  
NO  
COM  
NO  
NC  
NO  
Note: The Z-15GM is a reversible model and the NO and NC positions are  
reversed.  
Note: The NO and NC terminal arrangement is reversed for Models with  
reverse operation (Z-10FM).  
Molded Terminals  
COM (Black)  
(Red) NC  
(White) NO  
Connection Example  
Series Connection  
Parallel Connection  
( ) indicates wire color.  
Note: The Z-15GM is a reversible model and the NO and NC positions are  
reversed.  
Structure  
Drip-proof Construction  
• Without Terminal Protective Cover  
Rubber boot  
Fixed contact (b)  
Glued surface  
(adhesive is  
Movable spring  
filled between  
case and cover)  
Maintained-contact Models  
Contact Form  
Movable contact  
COM  
NC  
NO  
Spring pivot  
Fixed contact (a)  
• With Terminal Protective Cover  
Rubber boot (weather-resistive  
chloroprene is used)  
Pushbutton for resetting  
Stainless-steel stopper  
(improves sealing)  
Rubber packing (improves  
sealing between switch  
housing and terminal cover)  
Terminal protective covers are sold separately  
for maintenance purposes, which can be,  
however, used with the Z-  
For details, refer to page 22.  
@-B5V models only.  
8
Z
Dimensions  
(Unit: mm)  
Mounting  
Use M4 screws with plane washers and spring washers to mount the  
Switch. Tighten each mounting screw securely to a torque of 1.18 to  
1.47 N·m.  
When mounting the Switch to a panel, use a tightening torque of 2.94  
to 4.9 N·m for the hexagonal nuts on the actuator.  
Panel Mount Plunger  
Panel Mount Roller Plunger  
12.5+0.2dia.  
Two, 4.2 dia. mounting holes or M4  
12.5+0.2 dia.  
0
0
5+0.2  
0
0.1  
25.4  
13+0.2  
0
General-purpose  
Basic Models  
and Split-contact Models  
Terminals  
Basic Models  
Split-contact Models  
Screw Terminals (-B)  
Solder Terminal (-A) (“-A” is not included  
in the model numbers.)  
Screw Terminals (Y-B)  
5.6  
6.4  
9.2  
11.9  
0.1  
25.4  
11.9  
0.2  
17.45  
20  
20  
23  
17.1  
0.2  
17.45  
0.2  
17.45  
3
Five, M3.5 × 5.5  
terminal screws  
(with toothed  
washer)  
COM  
1
NO  
NC  
2
1
NO  
COM  
NC  
Three, M4 × 5.5  
Terminal screws  
(with toothed  
washer)  
2
3
Appropriate terminal screw tightening torque: 0.49  
to 0.78 N·m.  
Note: With reverse action models (Z-10FM), the  
49.2  
49.2  
Appropriate terminal screw tightening torque: 0.78  
to 1.18 N·m.  
positions of NO and NC terminals are  
Note: With reverse action models (Z-15GM), the positions of NO and NC terminals are reversed.  
reversed.  
Dimensions and Operating Characteristics  
The models, illustrations, and graphics are for screw-terminal models (-B). The “-A” at the end of the model number for solder terminal models has been omitted. For  
details of the terminals, see above.  
Pin Plunger  
2.3 dia.  
+0.075  
-0.025  
PT  
0.25  
23.3  
4.2  
dia. hole  
Z-15G-B  
Z-15H2-B  
Z-15H-B  
Z-15E-B  
Z-01H-B  
Z-10FY-B  
2.3SR *  
OP  
24.2  
9.2  
+0.075  
-0.025  
4.2  
+0.1  
-0.05  
4.36  
dia.  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel plunger  
49.2  
Operating  
Characteristics  
Model  
OF  
RF min.  
PT max.  
OT min.  
Z-15G-B  
Z-15H2-B  
Z-15H-B  
Z-15E-B  
Z-01H-B  
Z-10FY-B  
Operating force  
Release force  
Pretravel  
Overtravel  
Movement Differential MD max.  
2.45 to 3.43 N  
1.12 N  
0.4 mm  
0.13 mm  
0.05 mm  
1.96 to 2.5 N  
1.12 N  
0.3 mm  
0.13 mm  
0.005 to 0.008 mm  
1.96 to 2.75 N 6.12 to 7.85 N  
2.45 N max.  
0.78 N  
0.5 mm  
0.13 mm  
0.04 mm  
4.46 to 7.26 N  
1.12 N  
0.8 mm  
0.13 mm  
0.1 mm  
1.12 N  
0.3 mm  
0.13 mm  
0.025 mm  
1.12 N  
0.8 mm  
0.13 mm  
0.13 mm  
Operating Position OP  
15.9 0.4 mm  
5.2 dia.  
4 dia.  
Slim Spring Plunger  
PT  
0.25  
23.3  
*
Z-15GS-B  
Z-15HS-B  
Z-01HS-B  
Z-10FSY-B  
+0.075  
-0.025  
4.2  
dia. hole  
OP  
9 dia.  
24.2  
9.2  
+0.075  
-0.025  
4.2  
+0.1  
-0.05  
4.36  
dia.  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel plunger (flat, 1R chamfered)  
49.2  
Z-15GS-B  
Z-15HS-B  
Z-01HS  
Z-10FSY-B  
OF  
2.45 to 3.43 N  
1.12 N  
0.4 mm  
1.6 mm  
0.05 mm  
1.96 to 2.79 N  
1.12 N  
0.3 mm  
1.6 mm  
0.025 mm  
2.45 N max.  
0.78 N  
0.5 mm  
1.6 mm  
0.05 mm  
4.46 to 7.26 N  
1.12 N  
RF min.  
PT max.  
OT min.  
MD max.  
0.8 mm  
1.6 mm  
0.1 mm  
OP  
28.2 0.5 mm  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
9
Z
Short Spring Plunger  
12.3 dia.  
10 dia.  
Z-15GD-B  
Z-15HD-B  
Z-15ED-B  
Z-01HD-B  
Z-10FDY-B  
0.25  
23.3  
PT  
7.15 dia.  
12SR *  
+0.075  
-0.025  
4.2  
dia. hole  
OP  
24.2  
9.2  
+0.075  
-0.025  
4.2  
+0.1  
-0.05  
4.36  
dia.  
0.2  
17.45  
11.9  
0.1  
25.4  
* Plated iron plunger  
49.2  
Z-15GD-B  
Z-15HD-B  
Z-15ED-B  
Z-01HD-B  
Z-10FDY-B  
OF  
2.45 to 3.43 N  
1.12 N  
0.4 mm  
1.6 mm  
0.05 mm  
1.96 to 2.79 N  
1.12 N  
0.3 mm  
1.6 mm  
0.025 mm  
6.13 to 7.85 N  
1.12 N  
0.8 mm  
1.6 mm  
0.13 mm  
2.45 N max.  
0.78 N  
0.5 mm  
1.6 mm  
0.05 mm  
4.46 to 7.26 N  
1.12 N  
RF min.  
PT max.  
OT min.  
MD max.  
0.8 mm  
1.6 mm  
0.1 mm  
OP  
21.5 0.5 mm  
Panel Mount Plunger  
8.35 dia.  
0.25  
23.3  
Note: 1. Do not use the M12 mounting screw  
and the case mounting hole at the  
same time, or excessive pulling force  
will be imposed on the switch and the  
case and cover may be damaged.  
2. On the model Z-15GQ3-B, PT can be  
set to a value larger than that for the Z-  
15GQ.  
PT  
Z-15GQ-B  
Z-15HQ-B  
Z-15EQ-B  
Z-15GQ8-B *  
Z-01HQ-B  
Z-10FQY-B  
Z-15GQ3-B *  
11.9SR  
*1  
M12 × 1  
mounting screw  
*2  
OP  
13.1  
16.3  
+0.075  
-0.025  
4.2  
dia. hole  
*3  
*4  
16 dia.  
3. On the model Z-15GQ8-B, operating  
position can be adjusted by providing a  
screw in the plunger section.  
4. On the model Z-15GQ8-B, the M3 hole  
with a depth of 10 mm is a through  
hole. Take precautions so that no  
water or screw lock agent penetrates  
into the hole.  
9.2  
4.2+0.075  
-0.025  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
*1. Stainless-steel plunger  
*2. Two hexagonal nuts (2 t  
11.9  
* The external  
dimensions of the  
actuator vary.  
0.1  
25.4  
×
14 width across flats)  
49.2  
*3. Two lock nuts (2 t × 15.6 width across flats)  
*4. Incomplete screw part with a maximum length  
of 1.5 mm.  
Z-15GQ-B  
Z-15HQ-B  
Z-15EQ-B  
Z-01HQ-B  
Z-10FQY-B  
Z-15GQ3-B  
Z-15GQ8-B  
OF  
2.45 to 3.43 N  
1.12 N  
0.4 mm  
5.5 mm  
0.05 mm  
1.96 to 2.79 N  
1.12 N  
0.3 mm  
5.5 mm  
0.025 mm  
6.13 to 7.85 N  
1.12 N  
0.8 mm  
5.5 mm  
0.13 mm  
2.45 N max.  
0.78 N  
0.5 mm  
5.5 mm  
0.05 mm  
4.46 to 7.26 N  
1.12 N  
2.45 to 3.43 N  
1.12 N  
2.45 to 3.43 N  
1.12 N  
0.5 mm  
5.5 mm  
0.05 mm  
RF min.  
PT max.  
OT min.  
MD max.  
0.8 mm  
5.5 mm  
0.1 mm  
4.2 mm  
2.5 mm  
2.2 mm  
OP  
21.8 0.8 mm  
18.8 0.8 mm  
32.5 1 mm  
Panel Mount Roller Plunger  
Z-15GQ22-B Z-15EQ22-B  
Z-15HQ22-B Z-10FQ22Y-B  
0.25  
23.3  
12.7 dia. × 4.8 *1  
PT  
*2  
OP  
15.5  
M12 × 1  
mounting  
screw  
+0.075  
-0.025  
4.2  
dia. hole  
Note: Do not use the M12 mounting screw and  
the case mounting hole at the same time,  
or the case may be damaged.  
*3  
16 dia.  
16.3  
9.2  
+0.075  
-0.025  
4.2  
+0.1  
-0.05  
4.36  
dia.  
0.2  
17.45  
11.9  
0.1  
25.4  
*1. Stainless-steel roller  
*2. Two hexagonal nuts (3 t × 17 width across flats)  
49.2  
*3. Incomplete screw part with a maximum length of 1.5 mm.  
Z-15GQ22-B  
Z-15HQ22-B  
Z-15EQ22-B  
Z-10FQ22Y-B  
OF  
2.45 to 3.43 N  
1.12 N  
0.4 mm  
3.58 mm  
0.05 mm  
1.96 to 2.79 N  
1.12 N  
0.3 mm  
3.58 mm  
0.025 mm  
6.13 to 7.85 N  
1.12 N  
0.8 mm  
3.58 mm  
0.13 mm  
4.46 to 7.26 N  
1.12 N  
1 mm  
3.55 mm  
0.1 mm  
RF min.  
PT max.  
OT min.  
MD max.  
OP  
33.4 1.2 mm  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
10  
Z
Panel Mount Cross Roller Plunger  
Z-15GQ21-B Z-15EQ21-B  
0.25  
23.3  
12.7 dia. × 4.8 *1  
PT  
Z-15HQ21-B  
Z-15GQ21-B  
Z-15HQ21-B  
OF  
2.45 to 3.43 N  
1.12 N  
0.4 mm  
3.58 mm  
0.05 mm  
1.96 to 2.79 N  
1.12 N  
0.3 mm  
3.58 mm  
0.025 mm  
RF min.  
PT max.  
OT min.  
MD max.  
*2  
OP  
15.5  
16.3  
M12 × 1  
mounting  
screw  
+0.075  
-0.025  
4.2  
dia. hole  
*3  
16 dia.  
OP  
33.4 1.2 mm  
9.2  
+0.075  
-0.025  
Z-15EQ21-B  
4.2  
+0.1  
OF  
6.13 to 7.85 N  
1.12 N  
0.8 mm  
3.58 mm  
0.13 mm  
4.36  
dia.  
-0.05  
0.2  
17.45  
RF min.  
PT max.  
OT min.  
MD max.  
11.9  
0.1  
25.4  
*1. Stainless-steel roller  
*2. Two hexagonal nuts (3 t × 17 width  
49.2  
across flats)  
Note: Do not use the M12 mounting screw and the  
case mounting hole at the same time, or the  
case may be damaged.  
*3. Incomplete screw part with a maximum  
length of 1.5 mm.  
OP  
33.4 1.2 mm  
Leaf Spring  
Z-15GL-B  
t = 0.3*  
4.8  
0.8  
49.6  
+0.075  
-0.025  
4.2  
dia. hole  
OF max.  
RF min.  
OT *min.  
MD max.  
1.38 N  
0.14 N  
1.6 mm  
1.3 mm  
FP  
OP  
23.9  
9.2  
FP max.  
OP  
20.6 mm  
17.4 0.8 mm  
+0.075  
-0.025  
4.2  
+0.1  
4.36  
dia.  
-0.05  
0.2  
11.9  
17.45  
* When operating, be sure not  
to exceed 1.6 mm.  
0.1  
25.4  
* Stainless-steel spring lever  
49.2  
9.5 dia. × 4  
(plastic toller)  
Roller Leaf Spring  
Z-15GL2-B  
0.8  
46  
t = 0.3 *  
4.2+0.075  
-0.025 dia. hole  
OF max.  
RF min.  
OT *min.  
MD max.  
1.38 N  
0.14 N  
1.6 mm  
1.3 mm  
FP  
OP  
23.9  
9.2  
+0.075  
-0.025  
FP max.  
OP  
31.8 mm  
28.6 0.8 mm  
4.2  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
* When operating, be sure not  
to exceed 1.6 mm.  
0.1  
25.4  
* Stainless-steel spring lever  
49.2  
t = 1 *  
Short Hinge Lever  
Z-15GW21-B  
26.2  
4.9  
FP  
20.2  
OP  
16.9  
13.9  
OF max.  
RF min.  
OT min.  
MD max.  
1.57 N  
0.27 N  
2 mm  
1 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
4.2  
dia. hole  
+0.1  
4.36  
dia.  
-0.05  
FP max.  
OP  
24.8 mm  
19 0.8 mm  
0.2  
17.45  
* Stainless-steel lever  
11.9  
0.1  
25.4  
49.2  
t = 1 *  
Hinge Lever  
Z-15GW-B Z-15GW32-B  
4.9  
26.2  
Z-15HW-B  
Z-15GW3-B (Lever Length: 56R)*  
Z-10FWY-B  
FP  
20.2  
OP  
16.9  
4.2  
13.9  
9.2  
+0.075  
-0.025  
+0.075  
-0.025  
4.2  
dia. hole  
+0.1  
-0.05  
4.36  
dia.  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Z-15GW-B  
Z-15HW-B  
Z-15GW32-B  
Z-10FWY-B  
Z-15GW3-B  
* The external dimensions of the actuator vary.  
OF  
0.69 N max.  
0.14 N  
5.6 mm  
0.66 N max.  
0.14 N  
5.6 mm  
1.47 to 1.96 N  
0.92 N  
5.6 mm  
1.27 mm  
0.88 N max.  
0.14 N  
5.6 mm  
0.78 N max.  
0.15 N  
4.8 mm  
RF min.  
OT min.  
MD max.  
1.27 mm  
0.63 mm  
2.4 mm  
1.12 mm  
FP max.  
OP  
28.2 mm  
27.4 mm  
28.2 mm  
29.8 mm  
27.2 mm  
19 0.8 mm  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
11  
Z
Low-force Hinge Lever  
Z-15GW4-B  
t = 1 *  
PT  
4.9  
26.2  
20.2  
OP  
16.9  
13.9  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
274 mN  
34.3 mN  
10 mm  
5.6 mm  
1.27 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
4.2  
dia. hole  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
OP  
19 0.8mm  
* Stainless-steel lever  
49.2  
t = 0.8 *  
Z-15HW24-B  
5
2
120R  
26.2  
PT  
20.2  
OP  
16.9  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
58.8 mN  
4.90 mN  
19.8 mm  
10 mm  
13.9  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
4.2  
dia. hole  
+0.1  
2 mm  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
OP  
19.8 1.6 mm  
0.1  
25.4  
49.2  
* Stainless-steel lever  
Low-force Wire Hinge Lever  
Z-15HW52-B  
Z-15HW78-B (Lever Length: 110R) *  
Z-15HW52-B  
t = 1 *  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
58.8 mN  
4.90 mN  
8.3 mm  
5.6 mm  
0.65 mm  
3 max.  
20.2  
26.2  
PT  
OP  
16.9  
13.9  
OP  
19 1 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
4.2  
dia. hole  
+0.1  
-0.05  
4.36  
dia.  
* The external dimensions of the actuator vary.  
Note: AC electrical ratings: 10 A, 125/250 V.  
Z-15HW78-B  
0.2  
17.45  
11.9  
0.1  
25.4  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
39.2 mN  
2.94 mN  
10 mm  
6 mm  
* Stainless-steel wire lever  
49.2  
3 mm  
OP  
20 1 mm  
Short Hinge Roller Lever  
Z-15GW22-B Z-01HW22-B  
Z-15HW22-B Z-10FW22Y-B  
Z-15EW22-B  
9.5 dia. × 4  
(plastic roller)  
t = 1 *  
26.2  
Z-15GW2-B * Z-15HW2-B *  
Z-10FW2Y-B *  
FP  
OP  
20.2  
16.9  
13.9  
4.2  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
dia. hole  
+0.1  
-0.05  
4.36  
dia.  
* The external  
dimensions of the  
actuator vary.  
(Lever Length:  
48.5R)  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Z-15GW22-B  
Z-15HW22-B  
Z-15EW22-B  
Z-01HW22-B  
Z-10FW22Y-B  
Z-15GW2-B  
Z-15HW2-B  
Z-10FW2Y-B  
OF max.  
RF min.  
OT min.  
MD max.  
1.57 N  
0.41 N  
2.4 mm  
0.5 mm  
1.47 N  
0.41 N  
2.4 mm  
0.45 mm  
1.94 N  
0.41 N  
2.4 mm  
1.3 mm  
1.57 N  
0.27 N  
2.4 mm  
0.5 mm  
2.45 N  
0.34 N  
2.4 mm  
1 mm  
0.98 N  
0.22 N  
4 mm  
0.84 N  
0.22 N  
4 mm  
1.27 N  
0.22 N  
4 mm  
2 mm  
1.02 mm  
0.6 mm  
FP max.  
OP  
32.5 mm  
30.2 0.4 mm  
35.1 mm  
30.2 0.4 mm  
32.5 mm  
30.2 0.4 mm  
34.8 mm  
30.2 0.4 mm  
36.5 mm  
30.2 0.8 mm  
37.4 mm  
30.2 0.8 mm  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
12  
Z
Short Hinge Cross Roller Lever  
Z-15GW49-B  
26.2  
9.5 dia. × 4  
(plastic roller)  
t = 1 *  
Z-15GW54-B (Lever Length: 48.7R) *  
FP  
OP  
Z-15GW49-B  
Z-15GW54-B  
20.2  
16.9  
13.9  
4.2  
OF max.  
RF min.  
OT min.  
MD max.  
1.67 N  
0.41 N  
2.4 mm  
0.98 N  
0.22 N  
4 mm  
1 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
dia. hole  
0.51 mm  
+0.1  
4.36  
dia.  
-0.05  
FP max.  
OP  
33.3 mm  
31 0.4 mm  
37.3 mm  
31 0.8 mm  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
* The external dimensions of the actuator vary.  
20 dia. × 4  
R2 (plastic roller)  
Hinge Roller Lever  
Z-15GW25-B  
26.2  
t = 1*  
FP  
OP  
20.2  
OF max.  
RF min.  
OT min.  
MD max.  
0.98 N  
0.21 N  
4 mm  
16.9  
13.9  
4.2  
9.2  
+0.075  
-0.025  
1.6 mm  
4.2  
+0.075  
-0.025  
dia. hole  
+0.1  
FP max.  
OP  
47.5 mm  
41.2 0.8 mm  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Operating direction  
26.2  
Unidirectional Short Hinge Roller Lever  
Z-15GW2277-B  
9.5 dia. × 4  
(plastic roller)  
t = 1 *  
FP  
OP  
34.1 max.  
20.2  
16.9  
OF max.  
RF min.  
OT min.  
MD max.  
1.67 N  
0.41 N  
2.4 mm  
0.51 mm  
13.9  
4.2  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
dia. hole  
+0.1  
FP max.  
OP  
43.6 mm  
41.3 0.8 mm  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
t = 1 *  
Reverse Hinge Lever **  
Z-15GM-B  
4.9  
18.65  
FP  
20.2  
17.4  
OP  
OF max.  
RF min.  
OT min.  
MD max.  
1.67 N  
0.27 N  
5.6 mm  
0.89 mm  
13.9  
9.2  
+0.075  
-0.025  
4.2  
4.2 +0.075  
-0.025 dia. hole  
+0.1  
4.36  
dia.  
-0.05  
FP max.  
OP  
23.8 mm  
19 0.8 mm  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
t = 1 *  
9.5 dia. × 4  
(plastic roller)  
Reverse Short Hinge Roller Lever **  
Z-15GM22-B  
18.65  
Z-10FM22Y-B  
Z-15GM22-B  
Z-10FM22Y-B  
FP  
OP  
20.2  
17.4  
OF max.  
RF min.  
OT min.  
MD max.  
5.28 N  
1.67 N  
2 mm  
6.37 N  
1.67 N  
2 mm  
13.9  
9.2  
+0.075  
-0.025  
4.2  
0.28 mm  
0.56mm  
4.2 +0.075  
-0.025 dia. hole  
+0.1  
4.36  
dia.  
FP max.  
OP  
31.8 mm  
29.4 0.4 mm  
33 mm  
29.4 0.4 mm  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
t = 1*  
9.5 dia. × 4  
(plastic roller)  
Reverse Hinge Roller Lever **  
Z-15GM2-B  
18.65  
FP  
OP  
20.2  
OF max.  
RF min.  
OT min.  
MD max.  
2.35 N  
0.55 N  
4 mm  
17.4  
13.9  
9.2  
+0.075  
-0.025  
0.64 mm  
4.2  
4.2 +0.075  
-0.025 dia. hole  
+0.1  
FP max.  
OP  
35 mm  
30.2 0.8 mm  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
** The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating  
the levers. Reverse-type models are highly vibration- and shock-resistive because the pin plungers are normally pressed.  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
13  
Z
(Drip-proof) without Terminal Protective Cover  
Basic Models  
Terminals (Molded Terminals: Refer to page 21.)  
Without Terminal Protective Cover  
9.2  
20  
20  
0.2  
17.45  
COM  
1
NO  
NC  
2
Three, M4 × 5.5  
Terminal screws  
(with toothed  
washer)  
Note: With reverse action models (Z-15GM), the positions of NO and NC terminals are  
reversed.  
3
49.2  
Dimensions and Operating Characteristics  
The above illustration is for model without terminal protective cover.  
Pin Plunger  
Z-15G55-B  
3.9 dia.  
PT  
4.2 +0.075  
-0.025 dia. hole  
0.25  
23.3  
6SR *  
Z-01H55-B  
OP  
Z-15G55-B  
Z-01H55-B  
23.9  
9.2  
OF  
2.45 to 4.22 N  
1.12 N  
2.2 mm  
0.13 mm  
0.06 mm  
3.43 N max.  
0.78 N  
2.2 mm  
0.13 mm  
0.06 mm  
+0.075  
-0.025  
4.2  
RF min.  
PT max.  
OT min.  
MD max.  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel plunger  
49.2  
OP  
15.9 0.4 mm  
Short Spring Plunger  
Z-15GD55-B  
Z-01HD55-B  
15 dia.  
PT  
0.25  
11.9SR *  
23.3  
7.15 dia.  
4.2+0.075  
-0.025 dia. hole  
OP  
Z-15GD55-B  
Z-01HD55-B  
23.9  
9.2  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
1.8 mm  
1.6 mm  
0.06 mm  
3.63 N  
0.78 N  
1.9 mm  
1.6 mm  
0.06 mm  
+0.075  
-0.025  
4.2  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel plunger  
49.2  
OP  
21.5 0.5 mm  
Spring Plunger  
Z-15GK55-B  
17 dia.  
PT  
0.25  
11.9SR *  
23.3  
7.15 dia.  
4.2 +0.075  
-0.025 dia. hole  
OP  
23.9  
9.2  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
2.3 mm  
1.6 mm  
0.06 mm  
+0.075  
-0.025  
4.2  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel plunger  
49.2  
OP  
28.2 0.5 mm  
Z-15GK355-B  
17 dia.  
PT  
0.25  
11.9SR *  
23.3  
8.35 dia.  
4.2 +0.075  
-0.025 dia. hole  
OP  
23.5  
9.2  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
2.4 mm  
3.5 mm  
0.06 mm  
+0.075  
-0.025  
4.2  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel plunger  
49.2  
OP  
37.8 1.2 mm  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
14  
Z
Panel Mount Plunger  
Z-15GQ55-B  
8.35 dia.  
M12 × 1  
0.25  
23.3  
PT  
11.9SR  
*1  
Mounting  
screw  
*2  
OP  
13.1  
16.3  
4.2 +0.075  
-0.025 dia. hole  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
1.8 mm  
5.5 mm  
0.06 mm  
*3  
*4  
16 dia.  
9.2  
+0.075  
-0.025  
4.2  
OP  
21.8 0.8 mm  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
Note: Do not use the M12  
mounting screw and the  
case mounting hole at  
the same time, or the  
case may be damaged.  
11.9  
0.1  
25.4  
49.2  
*1. Stainless-steel plunger  
*2. Two hexagonal nuts (2 t × 14 width across flats)  
*3. Two lock nuts (2 t × 15.6 width across flats)  
*4. Incomplete screw part with a maximum length of 1.5 mm.  
Panel Mount Roller Plunger  
Z-15GQ2255-B  
0.25  
23.3  
12.7 dia. × 4.8 *1  
PT  
*2  
OP  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
1.8 mm  
3.58 mm  
0.06 mm  
15.5  
16.3  
M12 × 1  
mounting screw  
4.2+0.075  
-0.025 dia. hole  
*3  
16 dia.  
9.2  
+0.075  
-0.025  
OP  
33.4 1.2 mm  
4.2  
+0.1  
4.36  
dia.  
Note: Do not use the M12  
mounting screw and the  
case mounting hole at  
the same time, or the  
case may be damaged.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
49.2  
*1. Stainless-steel roller  
*2. Two hexagonal nuts (3 t × 17 width across flats)  
*3. Incomplete screw part with a maximum length of 1.5 mm.  
Panel Mount Cross Roller Plunger  
Z-15GQ2155-B  
0.25  
23.3  
12.7 dia. × 4.8 *1  
PT  
*2  
OP  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
1.8 mm  
3.58 mm  
0.06 mm  
15.5  
16.3  
M12 × 1  
mounting  
screw  
4.2 +0.075  
-0.025 dia. hole  
*3  
16 dia.  
9.2  
+0.075  
-0.025  
OP  
33.4 1.2 mm  
4.2  
+0.1  
4.36  
dia.  
Note: Do not use the M12  
mounting screw and the  
case mounting hole at  
the same time, or the  
case may be damaged.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
49.2  
*1. Stainless-steel roller  
*2. Two hexagonal nuts (3 t × 17 width across flats)  
*3. Incomplete screw part with a maximum length of 1.5 mm.  
Leaf Spring  
Z-15GL55-B  
t = 0.3 *  
4.8  
0.8  
49.6  
+0.075  
-0.025  
4.2  
dia. hole  
OF max.  
RF min.  
OT *min.  
MD max.  
1.96 N  
0.14 N  
1.6 mm  
1.3 mm  
FP  
OP  
23.9  
9.2  
FP max.  
OP  
20.6 mm  
17.5 0.8 mm  
+0.075  
-0.025  
4.2  
+0.1  
-0.05  
4.36  
dia.  
0.2  
* When operating, be sure not to  
exceed 1.6 mm.  
17.45  
* Stainless-steel spring lever  
11.9  
0.1  
25.4  
49.2  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
15  
Z
Roller Leaf Spring  
Z-15GL255-B  
9.5 dia. × 4  
(plastic roller)  
0.8  
46  
t = 0.3*  
4.2+0.075  
-0.025 dia. hole  
OF max.  
RF min.  
OT *min.  
MD max.  
1.96 N  
0.14 N  
1.6 mm  
1.3 mm  
FP  
OP  
23.9  
9.2  
FP max.  
OP  
31.8 mm  
28.6 0.8 mm  
+0.075  
-0.025  
4.2  
+0.1  
-0.05  
4.36  
dia.  
0.2  
17.45  
* When operating, be sure not to  
exceed 1.6 mm.  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Short Hinge Lever  
Z-15GW2155-B  
t = 1*  
26.2  
4.9  
FP  
20.2  
OP  
16.9  
13.9  
OF max.  
RF min.  
OT min.  
MD max.  
1.86 N  
0.27 N  
2 mm  
1 mm  
9.2  
+0.075  
-0.025  
4.2  
4.2 +0.075  
-0.025 dia. hole  
+0.1  
4.36  
dia.  
-0.05  
FP max.  
OP  
25 mm  
19 0.8 mm  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Long Hinge Lever  
Z-15GW4455-B  
t = 1 *  
4.9  
26.2  
FP  
20.2  
OP  
16.9  
13.9  
4.2  
OF max.  
RF min.  
OT min.  
MD max.  
0.88 N  
0.14 N  
5.6 mm  
3.5 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
dia. hole  
+0.1  
-0.05  
4.36  
dia.  
0.2  
FP max.  
OP  
33 mm  
19 1.2 mm  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Hinge Lever  
Z-15GW55-B  
t = 1*  
4.9  
26.2  
FP  
20.2  
OP  
16.9  
13.9  
4.2  
OF max.  
RF min.  
OT min.  
MD max.  
0.98 N  
0.14 N  
5.6 mm  
2 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
dia. hole  
+0.1  
-0.05  
4.36  
dia.  
FP max.  
OP  
28.2 mm  
19 0.8 mm  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Short Hinge Roller Lever  
Z-15GW2255-B  
9.5 dia. × 4  
(plastic roller)  
t = 1 *  
26.2  
Z-01HW2255-B  
FP  
OP  
Z-15GW2255-B Z-01HW2255-B  
20.2  
16.9  
13.9  
OF max.  
RF min.  
OT min.  
MD max.  
1.96 N  
0.41 N  
2.4 mm  
0.8 mm  
1.96 N  
0.27 N  
2.4 mm  
0.8 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
4.2  
dia. hole  
+0.1  
-0.05  
4.36  
dia.  
0.2  
FP max.  
OP  
32.9 mm  
30.2 0.4 mm  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
16  
Z
Hinge Roller Lever  
Z-15GW255-B  
9.5 dia. × 4  
(plastic roller)  
26.2  
t = 1 *  
FP  
OP  
20.2  
16.9  
13.9  
OF max.  
RF min.  
OT min.  
MD max.  
1.27 N  
0.21 N  
4 mm  
9.2  
+0.075  
-0.025  
4.2  
4.2 +0.075  
-0.025 dia. hole  
+0.1  
1.6 mm  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
FP max.  
OP  
36.5 mm  
30.2 0.8 mm  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Unidirectional Short Hinge Roller Lever  
Z-15GW227755-B  
Operating direction  
26.2  
9.5 dia. × 4  
(plastic roller)  
t = 1 *  
FP  
OP  
34.1 max.  
20.2  
16.9  
13.9  
4.2  
OF max.  
RF min.  
OT min.  
MD max.  
1.77 N  
0.49 N  
2.4 mm  
0.8 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
dia. hole  
+0.1  
-0.05  
4.36  
dia.  
0.2  
FP max.  
OP  
43.6 mm  
41.3 0.8 mm  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Reverse Hinge Lever *  
Z-15GM55-B  
t = 1 *  
4.9  
18.65  
FP  
20.2  
OP  
17.4  
13.9  
OF max.  
RF min.  
OT min.  
MD max.  
1.96 N  
0.27 N  
5.6 mm  
0.89 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
4.2  
dia. hole  
+0.1  
4.36  
dia.  
-0.05  
FP max.  
OP  
23.8 mm  
19 0.8 mm  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Reverse Short Hinge Roller Lever *  
Z-15GM2255-B  
t = 1 *  
9.5 dia. × 4  
(plastic roller)  
18.65  
FP  
OP  
20.2  
17.4  
13.9  
4.2  
OF max.  
RF min.  
OT min.  
MD max.  
5.69 N  
1.67 N  
2 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
-0.025  
dia. hole  
0.28 mm  
+0.1  
4.36  
dia.  
-0.05  
FP max.  
OP  
31.8mm  
29.4 0.4mm  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
Reverse Hinge Roller Lever *  
Z-15GM255-B  
9.5 dia. × 4  
(plastic roller)  
t = 1 *  
18.65  
FP  
OP  
20.2  
17.4  
13.9  
OF max.  
RF min.  
OT min.  
MD max.  
2.65 N  
0.55 N  
4 mm  
9.2  
+0.075  
-0.025  
4.2  
+0.075  
0.64 mm  
4.2  
dia. hole  
-0.025  
+0.1  
4.36  
dia.  
-0.05  
FP max.  
OP  
35 mm  
30.2 0.8 mm  
0.2  
17.45  
11.9  
0.1  
25.4  
* Stainless-steel lever  
49.2  
* The pin plungers of reverse-type models are continuously pressed by the actuator levers with compression coil springs and the pin plungers are freed by operating  
the levers.  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
17  
Z
Flexible Rod (Coil Spring)  
Z-15GNJ55-B  
*1  
6.1 dia.  
3.2 dia.  
PT  
Nylon rod  
30 Operating range *2  
38  
(111.3)  
43.4  
12 dia.  
Rubber cap  
0.25  
23.3  
OF max.  
PT max.  
0.49 N  
(20 mm)  
+0.075  
-0.025  
(13.6)  
16.3  
4.2  
dia. hole  
TT max.  
40 mm  
9.2  
*1. Operation is possible in any direction other than the  
axial direction (indicated by the arrow ).  
*2. Use only the area within the top 30 mm of the rod as  
the operating part. (Do not use the area that falls within  
80 mm from the mounting hole as the operating part.  
Using this area may cause damage to the nylon rod.  
+0.075  
-0.025  
4.2  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
0.1  
25.4  
49.2  
Flexible Rod (Steel Wire)  
Z-15HNJS55-B  
*1  
PT  
1-dia. stainless  
steel wire *3  
30 Operating range *2  
0.4  
100  
Four, M3 set screws  
with hexagonal holes  
(130.1)  
(22)  
12 dia.  
Rubber cap  
0.25  
23.3  
4.2 +0.075  
-0.025 dia. hole  
(13.8)  
16.3  
OF max.  
PT max.  
0.15 N  
(25 mm)  
9.2  
+0.075  
-0.025  
4.2  
*1. Operation is possible in any direction other than the axial  
direction (indicated by the arrow ).  
+0.1  
4.36  
dia.  
-0.05  
0.2  
17.45  
11.9  
*2. Use only the area within the top 30 mm of the rod as the  
operating part. (Do not use the area that falls within 100  
mm from the mounting hole as the operating part.  
Using this area may cause damage to the steel wire.)  
*3. The steel wire can be replaced if damaged.  
(Model: Lever for HNJS55)  
0.1  
25.4  
49.2  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
18  
Z
(Drip-proof) with Terminal Protective Cover  
Basic Models  
Dimensions and Operating Characteristics  
Pin Plunger  
Z-15GA55-B5V  
6SR *  
PT  
3.9 dia.  
0.25  
23.3  
OP  
14.7  
(11)  
OF max. 2.45 to 4.22 N  
+0.075  
-0.025  
RF min.  
PT max.  
OT min.  
MD max.  
1.12 N  
2.2 mm  
0.13 mm  
0.06 mm  
4.2  
19.2  
+0.1  
4.36  
dia.  
-0.05  
+0.075  
-0.025  
4.2  
dia. hole  
0.2  
17.45  
0.1  
25.4  
13.7  
OP  
15.9 0.4 mm  
52.8  
* Stainless-steel plunger  
(28.8)  
17 dia.  
Z-15GK3A55-B5V  
PT  
0.25  
23.3  
11.9SR *  
8.35 dia.  
OP  
14.7  
(11)  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
2.4 mm  
3.5 mm  
0.06 mm  
+0.075  
-0.025  
4.2  
19.2  
+0.1  
-0.05  
4.36  
dia.  
4.2 +0.075  
-0.025 dia. hole  
OP  
37.8 1.2 mm  
0.2  
17.45  
0.1  
25.4  
13.7  
52.8  
* Stainless-steel plunger  
(28.8)  
8.35 dia.  
Panel Mount Plunger  
Z-15GQA55-B5V  
PT  
OP  
0.25  
23.3  
11.9SR *1  
M12 P = 1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
1.8 mm  
5.5 mm  
0.06 mm  
*2  
*3  
13.1  
16 dia.  
16.3  
OP  
21.8 0.8 mm  
(11)  
+0.075  
-0.025  
4.2  
19.2  
Note: Do not use the M12  
mounting screw and the  
case mounting hole at  
the same time, or the  
case may be damaged.  
+0.1  
4.36  
dia.  
-0.05  
4.2 +0.075  
-0.025dia. hole  
0.2  
17.45  
0.1  
25.4  
13.7  
*1. Stainless-steel plunger  
52.8  
(28.8)  
*2. Two hexagonal nuts (2 t × 14 width across flat)  
*3. Two lock nuts (2 t × 15.6 width across flats)  
PT  
0.25  
23.3  
Panel Mount Roller Plunger  
Z-15GQ22A55-B5V  
12.7 dia. × 4.8 *1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
1.8 mm  
3.58 mm  
0.06 mm  
*2  
OP  
M12 P = 1  
15.5  
16 dia.  
16.3  
19.2  
OP  
33.4 1.2 mm  
Note: Do not use the M12  
mounting screw and the  
case mounting hole at  
the same time, or the  
case may be damaged.  
(11)  
+0.075  
-0.025  
4.2  
+0.1  
4.36  
dia.  
-0.05  
4.2 +0.075  
-0.025 dia. hole  
0.2  
17.45  
0.1  
25.4  
13.7  
*1. Stainless-steel roller  
*2. Two hexagonal nuts (3 t × 17 width across flats)  
52.8  
(28.8)  
PT  
OP  
0.25  
23.3  
Panel Mount Cross-roller Plunger  
Z-15GQ21A55-B5V  
12.7 dia. × 4.8 *1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.30 N  
1.12 N  
1.8 mm  
3.58mm  
0.06 mm  
*2  
M12 P = 1  
15.5  
16 dia.  
16.3  
OP  
33.4 1.2 mm  
Note: Do not use the M12  
mounting screw and the  
case mounting hole at  
the same time, or the  
case may be damaged.  
(11)  
+0.075  
-0.025  
4.2  
19.2  
+0.1  
4.36  
dia.  
-0.05  
4.2 +0.075  
-0.025 dia. hole  
0.2  
17.45  
0.1  
25.4  
13.7  
*1. Stainless-steel roller  
52.8  
(28.8)  
*2. Two hexagonal nuts (3 t × 17 width across flats)  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
19  
Z
Long Hinge Lever  
Z-15GW44A55-B5V  
t = 1 *  
4.9  
26.2  
FP  
20.2  
OP  
OP  
OP  
16.9  
13.9  
OF max.  
RF min.  
OT min.  
MD max.  
0.88 N  
0.14 N  
5.6 mm  
3.5 mm  
(11)  
+0.075  
-0.025  
4.2  
19.2  
+0.1  
4.36  
dia.  
-0.05  
4.2 +0.075  
-0.025 dia. hole  
FP max.  
OP  
33 mm  
19 1.2 mm  
0.2  
17.45  
0.1  
25.4  
13.7  
52.8  
* Stainless-steel lever  
(28.8)  
Hinge Lever  
t = 1 *  
Z-15GWA55-B5V  
4.9  
26.2  
FP  
20.2  
OF max.  
RF min.  
OT min.  
MD max.  
0.98 N  
0.14 N  
5.6 mm  
2 mm  
16.9  
13.9  
(11)  
+0.075  
-0.025  
4.2  
19.2  
FP max.  
OP  
28.2 mm  
19 0.8 mm  
+0.1  
-0.05  
4.36  
dia.  
4.2 +0.075  
-0.025 dia. hole  
0.2  
17.45  
0.1  
25.4  
13.7  
52.8  
* Stainless-steel lever  
(28.8)  
Short Hinge Roller Lever  
Z-15GW22A55-B5V  
t = 1 *  
9.5 dia. × 4  
(plastic roller)  
26.2  
FP  
OF max.  
RF min.  
OT min.  
MD max.  
1.96 N  
0.41 N  
2.4 mm  
0.8 mm  
20.2  
16.9  
13.9  
(11)  
+0.075  
-0.025  
4.2  
19.2  
FP max.  
OP  
32.9 mm  
30.2 0.4 mm  
+0.1  
4.36  
dia.  
-0.05  
4.2 +0.075  
-0.025 dia. hole  
0.2  
17.45  
0.1  
25.4  
13.7  
52.8  
* Stainless-steel lever  
(28.8)  
Hinge Roller Lever  
Z-15GW2A55-B5V  
9.5 dia. × 4  
(plastic roller)  
26.2  
t = 1 *  
FP  
OP  
OF max.  
RF min.  
OT min.  
MD max.  
1.27 N  
0.21 N  
4 mm  
20.2  
16.9  
13.9  
(11)  
+0.075  
-0.025  
1.6 mm  
4.2  
19.2  
FP max.  
OP  
36.5 mm  
30.2 0.8 mm  
+0.1  
4.36  
dia.  
-0.05  
4.2 +0.075  
-0.025dia. hole  
0.2  
17.45  
0.1  
25.4  
13.7  
52.8  
* Stainless-steel lever  
(28.8)  
Unidirectional Short Hinge Roller Lever  
Z-15GW2277A55-B5V  
Operating direction  
26.2  
9.5 dia. × 4  
(plastic roller)  
t = 1 *  
FP  
OP  
34.1 max.  
OF max.  
RF min.  
OT min.  
MD max.  
1.77 N  
0.49 N  
2.4 mm  
0.8 mm  
20.2  
16.9  
13.9  
(11)  
+0.075  
-0.025  
4.2  
19.2  
FP max.  
OP  
43.6 mm  
41.3 0.8 mm  
+0.1  
4.36  
dia.  
-0.05  
+0.075  
4.2  
dia. hole  
-0.025  
0.2  
17.45  
0.1  
25.4  
13.7  
52.8  
* Stainless-steel lever  
(28.8)  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
20  
Z
(Drop-proof) with Modeled terminals  
Basic Models  
Molded Terminals  
L/R Type (The following illustration is the R type.)  
D Type  
c
a
a
c
38  
5
b
b
Size (mm)  
Lead wire  
Size (mm)  
a
b
c
a
b
c
Lead wire  
VSF  
VCT  
VSF  
VCT  
12  
4
12  
12  
4
13  
19 11 16  
19 11 20  
Lead Wire Specifications  
Specifications Nominal cross sec-  
tional area (mm2)  
Finished outer  
diameter (mm)  
Connection  
to terminal  
Length (m)  
Lead wire  
VSF (single-core, vinyl cord)  
Approx. 3.1 dia.  
Black:COM  
White:NO  
Red: NC  
1.25  
1, 3  
Three-core:  
approx. 10.5 dia.  
VCT (vinyl-insulated cable)  
Note: 1. No models with molded terminals are approved by UL, CSA, or EN.  
2. Molded terminals are not available on all models. Contact your OMRON representative for applicable products.  
Maintained-contact Models  
Dimensions and Operating Characteristics  
Pin Plunger  
Z-15ER  
2.3 dia.  
+0.075  
-0.025  
PT  
0.25  
23.3  
4.2  
dia. hole  
2.3SR *1  
Plunger  
OF max. 1.96 to 2.50 N  
Reset position  
OP  
7.1 min.  
6.4 dia.  
21.4  
6.4  
PT max.  
OT min.  
0.4 mm  
0.13 mm  
+0.075  
-0.025  
+0.1  
-0.05  
4.2  
4.36  
dia.  
Reset free  
position  
0.3  
14.3  
25.4  
OP  
15.9 0.4 mm  
11.9  
Reset button *2  
0.1  
0.2  
9.5 max.  
17.45  
49.2  
Reset Button  
NO  
NC  
COM  
OF max. 0.55 to 2.79 N  
*1. Stainless steel plunger  
*2. Plastic plunger  
OT min.  
0.4 mm  
Slim Spring Plunger  
Z-15ESR  
5.2 dia.  
4 dia.  
0.25  
23.3  
*1  
PT  
Plunger  
+0.075  
-0.025  
4.2  
dia. hole  
OF max.  
PT max.  
OT min.  
2.65 N  
0.4 mm  
1.6 mm  
OP  
Reset position  
7.1 min.  
9 dia.  
21.4  
6.4  
OP  
28.2 0.5 mm  
+0.075  
4.2  
-0.025  
+0.1  
6.4 dia.  
4.36  
dia.  
-0.05  
Reset free  
0.3  
14.3  
position 9.5 max.  
11.9  
Reset button *2  
Reset Button  
0.1  
25.4  
0.2  
17.45  
49.2  
*1. Stainless steel plunger (tip only, flat, R1 bevel).  
*2. Plastic plunger  
OF max.  
OT min.  
2.79 N  
0.4 mm  
Hinge Lever  
Z-15EWR  
t = 1 *1  
4.9  
26.2  
Lever Tip  
FP  
OF max.  
OT min.  
0.54 N  
5.6 mm  
Reset position  
7.1 min.  
20.2  
OP  
16.9  
13.9  
FP max.  
OP  
28.2 mm  
19 0.8 mm  
6.4  
+0.075  
4.2  
-0.025  
+0.1  
4.36  
dia.  
6.4 dia.  
-0.05  
Reset free  
position  
9.5 max.  
0.3  
14.3  
25.4  
4.2 +0.075  
-0.025 dia. hole  
Reset button *2  
11.9  
0.1  
0.2  
17.45  
Reset Button  
49.2  
*1. Stainless steel lever  
*2. Plastic plunger  
OF max.  
OT min.  
2.94 N  
0.4 mm  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
21  
Z
Accessories (Order Separately)  
A Terminal Protective Cover, Actuators, and a Separator are available.  
Drip-proof Terminal  
Cover (Order Separately)  
The Drip-proof Terminal Protective Cover is provided for maintenance for Z-@A55-B5V Switches.  
Ordering Information  
Dimensions  
(Unit: mm)  
Name  
Model  
Drip-proof Terminal  
Protective Cover  
17.4  
13.5 dia. 17 dia.  
AP-DV  
48.521  
11  
Mounting bracket  
7.5  
27.9  
15  
17.4  
0.6  
51.6  
9
17.4  
29.5±1  
Terminal Covers (Sold Separately)  
Separator (Sold Separately)  
The Terminal Covers can be attached to Z, A, X, and DZ Switches.  
Use a Separator when it is difficult to  
provide a sufficient insulation distance or  
when using the Switch near metal parts or  
copper wires.  
The Terminal Cover is secured with mounting screws and protects the casing and terminal wires  
from dust, vibration, or fingers, thus preventing terminal short-circuiting, ground faults, wire  
disconnection or improper connection, and electric shock accidents.  
Terminal Covers made of phenol resin have five or six thin wall sections. These sections can be  
torn open for providing holes for lead cables at desired points.  
A terminal cover can’t be used in the case of using an actuator sold separately.  
Operation Information  
Model  
SEPARATOR FOR Z  
Operation Information  
Application Soldering terminal use Screw terminal use  
Remarks  
Material  
Mounting direction  
Side mounting  
Model  
AP-Z  
Phenol resin  
AP-A  
AP-B  
---  
Metal press mold Side mounting  
Vinyl chloride Side mounting  
AP1-A  
AP1-B  
Used for AP-A and AP-B  
---  
Note: Use a Terminal Cover for screw terminals fir DZ-series Switches with soldering terminals.  
22  
Z
Dimensions (Unit: mm)  
Terminal Covers  
52.8  
25.4  
53.8  
25.4  
AP-A  
Soldering Terminal Use  
(Phenol Resin)  
AP-B  
Screw Terminal Use  
(Phenol Resin)  
4.3+0.2  
4.3+0.2  
4.3+0.2  
4.3+0.2  
0
0
0
0
8
8
8
8
16.3  
6.5  
20.2  
6.5  
2.15R  
2.15R  
21  
21  
Note: The Cover has five thin, easy-to-separate  
portions for easy lead wire connections.  
Note: The Cover has six thin, easy-to-separate  
portions for easy lead wire connections.  
55.4  
25.4  
54.4  
25.4  
AP1-A  
Soldering Terminal Use  
AP1-B  
Screw Terminal Use  
4.3+0.2  
4.3+0.2  
4.3+0.2  
4.3+0.2  
0
0
0
0
(Metal Press Mold)  
(Metal Press Mold)  
8
8
17.1  
21  
2.15R  
2.15R  
7.2  
7
8.5 22.6  
8.5 22.6  
Note: The Cover has five holes for easy lead wire connections.  
Note: The Cover has six holes for easy lead wire connections.  
Two, 4.2 dia.  
AP-Z  
Pressure plate  
(t1 steel)  
52.8  
25.4  
Soldering or Screw Terminal Use  
21  
Cable Pull-out Dimension  
(Vinyl Chloride)  
7
14  
A-A' cross-section  
B-B' cross-section  
21  
6 dia.  
15 8 dia.  
13  
39  
46  
Note: A 6-dia. or 8-dia. cable can be  
used by cutting the cable pull-out  
hole to the size of the cable to be  
used.  
A
B
A'  
B'  
13  
15  
M3 × 20 Phillips screw  
(with plane washer and nut)  
12  
Nut  
Note: Each dimension has a tolerance of 0.4 mm unless otherwise specified. ( 0.8 mm for the AP-Z)  
Separator  
Two, 4.5 dia.  
13.5  
27 0.5  
Note: 1. Each dimension has a tolerance of 0.4 mm unless otherwise specified.  
2. The material is EAVTC (Epoxide Alkyd Varnished Tetron Cloth) and its heat-resisting  
temperature is 130°C.  
11.9  
25.4 0.2  
49.2 0.5  
t = 0.51  
23  
Z
Actuators (Sold Separately)  
A Switch can be actuated by a cam or an appropriate object, in which case, use one of the following Actuators according to the application.  
Ordering Information  
Actuator  
Application  
Common to Z and X models  
XAA-1  
Hinge lever  
Hinge roller lever  
ZAA-2  
Short  
Medium  
Long  
ZAQ-3  
ZAQ-2  
ZAQ-1  
Panel mount plunger  
Panel mount roller plunger  
ZAQ-22  
Dimensions (Unit: mm) and Operating Characteristics  
Note: These Actuators are not provided with Switches.  
Two, M4 30  
Two, M4  
Hinge Lever  
XAA-1  
Model  
Z-15G-B  
X-10G-B  
Operating characteristics  
19.1  
Operating force OF max.  
4.90 N  
1.67 N  
12.7 mm  
2.2 mm  
4.90 N  
1.67 N  
12.7 mm  
3.3 mm  
Release force  
Overtravel  
RF min.  
OT min.  
X A A - 1  
*
XAA-1  
Movement Differential MD max.  
7
Free Position  
Operating Position OP  
FP max.  
32.9 1.6 mm  
28.9 1.6 mm  
FP  
OP  
29.4  
Note: This Actuator can be used with the Z-15G(-B) and X-  
10G(-B). When mounting the Switch, set the overtravel to  
between 32% and 100%, taking into consideration the  
operating body and the distance between the Actuator  
and the dog.  
20.5  
38.5  
* Stainless steel  
11.9  
25.4 0.1  
49.2  
Two, M4 30  
Two, M4  
Hinge Roller Lever  
ZAA-2  
Z-15G-B  
X-10G-B  
19.1  
OF max.  
RF min.  
OT min.  
MD max.  
4.90 N  
1.67 N  
12.7 mm  
4.90 N  
1.67 N  
12.7 mm  
22.2  
9.5 dia. × 4.8 *1  
2.2 mm  
3.3 mm  
FP max.  
OP  
44.5 1.6 mm  
40.4 1.6 mm  
*2  
7
Note: This Actuator can be used with the Z-15G(-  
B) and ZX-10G(-B). When mounting the  
Switch, set the overtravel to between 32%  
and 100%, taking into consideration the  
operating body and the distance between  
the Actuator and the dog.  
FP  
OP  
29.4  
20.5  
38.5  
*1. Stainless steel roller  
*2. Stainless steel  
11.9  
25.4 0.1  
49.2  
Short Panel Mount Plunger  
7.9 dia.  
23.3  
12SR  
ZAQ-3  
M12 × 1 mounting  
screw  
2 t × 14 width  
across flats  
ZAQ-3  
PT  
Z-15E-B  
X-10G-B  
*1  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
8.34 N  
1.12 N  
0.8 mm  
4.8 mm  
0.15 mm  
5.39 N  
1.12 N  
1 mm  
4.5 mm  
0.2 mm  
OP  
17.5  
*3  
14.5  
dia.  
1.6  
2 t × 15.6 width  
across flats  
Two, M4 nuts  
20.7  
OP  
27.8 1.5 mm  
24.2  
22.6  
Note: 1. This Actuator (pin plunger) can be used  
with Standard Pin Plungers (Z-15G(-B),  
Z-15E(-B), X-10G(-B), DZ-10G-1A(-1B))  
for the Z, X, and DZ models.  
*3  
*2  
13.5  
Two, M4 × 25 screws  
25.4 0.1  
52.4  
20.7  
*1. Stainless-steel pin plunger  
*2. Bronze frame  
*3. Incomplete screw section part with a maximum of 1.5 mm  
Note: Each dimension has a tolerance of 0.4 mm unless otherwise specified.  
24  
Z
Medium Panel Mount Plunger  
ZAQ-2  
7.9 dia.  
PT  
23.3  
12SR  
M12 × 1 mounting screw  
*1  
ZAQ-2  
Z-15E-B  
X-10G-B  
2 t × 14 width across  
flats  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
8.34 N  
1.12 N  
0.8 mm  
4.8 mm  
0.15 mm  
5.39 N  
1.12 N  
1 mm  
4.5 mm  
0.2 mm  
OP  
42.8  
24.2  
2 t × 15.6 width  
across flats  
14.5  
dia.  
*3  
1.6  
OP  
53.2 1.5 mm  
Note: This Actuator (pin plunger) can be used with  
Standard Pin Plungers (Z-15G(-B), Z-15E(-  
B), X-10G(-B), DZ-10G-1A(-1B)) for the Z,  
X, and DZ models.  
Two, M4 × 25 screws  
20.7  
22.6  
*2  
13.5  
Two, M4 nuts  
25.4 0.1  
52.4  
20.7  
*1. Stainless-steel pin plunger  
*2. Copper alloy frame  
*3. Incomplete screw section part with a maximum of 1.5 mm  
Long Panel Mount Plunger  
ZAQ-1  
7.9 dia.  
PT  
23.3  
12SR  
*1  
ZAQ-1  
Z-15E-B  
X-10G-B  
M12 × 1 mounting screw  
OF max.  
8.34 N  
1.12 N  
0.8 mm  
20.6 mm  
0.15 mm  
5.39 N  
1.12 N  
1 mm  
20.4 mm  
0.2 mm  
RF min.  
PT max.  
OT min.  
MD max.  
2 t × 14 width across  
flats  
OP  
42.8  
24.2  
OP  
69.1 1.5 mm  
2 t × 15.6 width  
across flats  
Note: This Actuator (pin plunger) can be used with  
Standard Pin Plungers (Z-15G(-B), Z-15E(-  
B), X-10G(-B), DZ-10G-1A(-1B)) for the Z,  
X, and DZ models.  
14.5  
dia.  
*3  
1.6  
Two, M4 × 25 screws  
20.7  
22.6  
*2  
13.5  
Two, M4 nuts  
25.4 0.1  
52.4  
20.7  
*1. Stainless-steel pin plunger  
*2. Copper alloy frame  
*3. Incomplete screw section part with a maximum of 1.5 mm  
Panel Mount Roller Plunger  
ZAQ-22  
48  
12.7 dia. *1  
4.8  
PT  
23.3 0.25  
Two hex nuts 5-mm  
thickness, 19 mm  
between opposing edges  
With groove for roller  
ZAQ-22  
Z-15E-B  
DZ-10G-1B  
OF max.  
8.34 N  
1.12 N  
2 mm  
3.58 mm  
0.15 mm  
11.1 N  
1.12 N  
2 mm  
1 mm  
0.46 mm  
penetration  
OP  
RF min.  
PT max.  
OT min.  
MD max.  
M12 × 1 mounting  
screw  
*3  
18.9  
23.9  
1.6  
14.5  
dia.  
OP  
37 0.8 mm  
35.4 1.2 mm  
20.7  
Note: This Actuator (roller plunger) can be used with  
standard pin plungers (Z-15G(-B), Z-15E(-B),  
and DZ-10G-1A(-1B)). It cannot be used with  
X models.  
Two, M4 × 25  
screws  
Spring washer  
*2  
25.4 0.2  
49.2  
20.7  
11.9  
*1. Stainless-steel pin plunger  
*2. Steel frame  
*3. Incomplete screw section part with a maximum of 1.5 mm  
Note: Each dimension has a tolerance of 0.4 mm unless otherwise specified.  
25  
Z
Safety Precautions  
Refer to Safety Precautions for All Basic Switches.  
Precautions for Safe Use  
Incorrect  
Correct  
Separate the  
installation lo-  
cation from  
Terminal Connection  
heat sources.  
When soldering lead wires to the Switch, make sure that the capacity  
of the soldering iron is 60 W maximum. Do not take more than 5 s to  
solder any part of the Switch. The characteristics of the Switch will  
deteriorate if a soldering iron with a capacity of more than 60 W is  
applied to any part of the Switch for 5 s or more.  
Mount a cover if the switch is to be installed in a location where  
worker inattention could result in incorrect operation or accidents.  
Operation  
Correct  
Incorrect  
Make sure that the switching frequency or speed is within the  
specified range.  
1.If the switching speed is extremely slow, the contact may not be  
switched smoothly, which may result in a contact failure or  
contact welding.  
(preventing malfunctions)  
2.If the switching speed is extremely fast, switching shock may  
damage the Switch soon. If the switching frequency is too high,  
the contact may not catch up with the speed.  
The rated permissible switching speed and frequency indicate the  
switching reliability of the Switch.  
The life of a Switch is determined at the specified switching speed.  
The life varies with the switching speed and frequency even when  
they are within the permissible ranges. In order to determine the  
life of a Switch model to be applied to a particular use, it is best to  
conduct an appropriate durability test on some samples of the  
model under actual conditions.  
Subjecting the switch to continuous vibration or shock may result in  
contact failure or faulty operation due to abrasion powder and in  
reduced durability. Excessive vibration or shock will cause the  
contacts to operate malfunction or become damaged. Mount the  
switch in a location that is not subject to vibration or shock and in a  
direction that does not subject the switch to resonance.  
If silver contacts are used with relatively low frequency for a long  
time or are used with microloads, the sulfide coating produced on  
the contact surface will not be broken down and contact faults will  
result. Use a microload switch that uses gold contacts.  
Do not use the switch in atmospheres with high humidity or heat or  
in harmful gases, such as sulfide gas (H2S, SO2), ammonia gas  
(NH3), nitric acid gas (HNO3), or chlorine gas (Cl2). Doing so may  
impair functionality, such as with damage due to contacting faults  
or corrosion.  
Make sure that the actuator travel does not exceed the permissible OT  
position. The operating stroke must be set to 70% to 100% of the rated OT.  
Precautions for Correct Use  
The switch includes contacts. If the switch is used in an atmosphere  
with silicon gas, arc energy may cause silicon oxide (SiO2) to  
accumulate on the contacts and result in contact failure. If there is  
silicon oil, silicon filling, silicon wiring, or other silicon products in the  
vicinity of the switch, use a contact protection circuit to limit arcing  
and remove the source of the silicon gas.  
Mounting Location  
Do not use the switch alone in atmospheres such as flammable or  
explosive gases. Arcing and heat generation associated with  
switching may cause fires or explosions.  
Switches are generally not constructed with resistance against water. Use  
a protective cover to prevent direct spraying if the switch is used in  
locations subject to splashing or spurting oil or water, dust adhering.  
Mounting  
Always make sure that the power is turned OFF before mounting,  
removing, or wiring the Switch, or performing maintenance.  
Electric shock or burning may occur.  
Incorrect  
Correct  
Selecting Models  
We recommend using Drip-proof Models (protection equivalent to  
IP62) in locations subject to floating dirt and dust. Other models do not  
have a protective structure.  
Terminal box  
Terminal box  
Wiring  
Install the switch in a location that is not directly subject to debris  
and dust from cutting. The actuator and the switch body must be  
protected from accumulated cutting debris and dirt.  
Use wire sizes that are suitable to the applied voltage and carried  
current.  
If you use a soldering iron to solder the wires, do not allow the tip of  
the soldering iron to exceed 380°C. If a Switch is used with  
insufficient soldering, abnormal heat and burning may occur.  
Solder for no more than 5 s at 350°C and for no more than 3 s at  
380°C. If heat is applied for too long, the case may melt, the lead  
wire coverings may be scorched, and other characteristics of the  
Switch may deteriorate.  
Incorrect  
Correct  
Do not use the switch in locations subject to hot water (greater than  
60°C) or in water vapor.  
Do not use the switch outside the specified temperature and  
atmospheric conditions.  
The permissible ambient temperature depends on the model. (Refer to  
the specifications in this catalog.) Sudden thermal changes may cause  
thermal shock to distort the switch and result in faults.  
Tightening  
The suitable tightening torque for screw terminals is given below.  
Screw terminals except for those on Split-contact Models (Z-10FY-  
B): 0.78 to 1.18 N·m  
Screw terminals on Split-contact Models (Z-10FY-B):  
0.49 to 1.18 N·m  
Operation  
Make sure that the switching speed and frequency are is within the  
specified ranges.  
1. If the switching speed is extremely slow, the contacts may not be switched  
smoothly, which may result in a contact failure or contact welding.  
26  
Z
2. If the switching speed is extremely fast, switching shock may  
damage the Switch prematurely. If the switching frequency is too  
high, the contacts may not be able to keep up with the speed.  
The rated permissible switching speed and frequency indicate the  
switching reliability of the Switch.  
The life of a Switch is determined at the specified switching speed.  
The life varies with the switching speed and frequency even when  
they are within the permissible ranges. Always conduct appropriate  
durability tests under actual conditions before using a Switch.  
Models with Drip-proof Terminal Cover (Z-@A55-B5V)  
Wiring  
To attach the Protective Cover to the case, hold the cover in almost  
parallel to the case and then push it to the case. If the cover is  
pushed diagonally, the rubber packing may slip off, degrading the  
sealability of the Switch.  
Terminal with  
toothed  
washer  
Make sure that the actuator travel does not exceed the permissible OT  
position. The operating stroke must be set to 70% to 100% of the rated OT.  
Panel Mount Switch (Z-15@Q@, Z-01@Q@)  
Rubber packing  
When mounting the panel mount plunger model with screws on a  
side surface, be careful of the dog angle and operation speed.  
Excessive dog angle or operation speed may damage the Switch.  
When using the panel mount plunger model mounted with screws  
on a side surface, be careful not to apply a large shock. Applying a  
shock exceeding 1,000 m/s2 may damage the Switch.  
Use round solderless terminals having the  
following dimensions to connect leads to the  
terminals. Tighten the screws of terminals to  
a torque of 0.78 to 1.18 N·m. Use the  
4.3 dia.  
When using the panel mount plunger model mounted with screws  
on a side surface, remove the hexagonal nuts from the actuator.  
8
High-sensitivity Switch (Z-15H)/  
20 max.  
terminal shown below.  
A cable 8.5 to 10.5 mm in diameter can be  
Extra-high-sensitivity Switch (Z-15H2)  
applicable to the sealing rubber of the lead outlet of the Switch. A  
two-core or three-core VCT cable having a cross-sectional area of  
1.25 mm2 is especially suitable for this.  
Use M4 small screws with spring toothed washer are used as the  
terminal screws.  
When using the Switch in a DC circuit, be sure to provide an arc  
suppressor as well because the small contact gap of the Switch  
may result in contact troubles.  
In an application where a high repeat accuracy is required, limit the  
current that flows through the Switch to within 0.1 A. Also, use a  
relay to control a high-capacity load if the Switch is connected to  
such a load. (In this case, the exciting current of the relay coil is the  
load of the Switch.)  
Drip-proof Switch (Z-@55)  
The Switch is not perfectly oil-tight; so do not dip it in oil or water.  
The rubber boots are made from weather-resistive chloroprene  
rubber.  
Do not use Basic Switches in places with radical changes in  
temperature.  
Rubber boots and rubber caps will tend to harden at lower ambient  
temperatures. If an Actuator is used in a pressed state for an  
extended period of time at low temperatures, it may return slowly or  
it may not return at all. OMRON can provide special Actuators for  
use at low temperature with rubber boots or rubber caps made of  
silicon rubber, which has superior resistance to cold. Ask your  
OMRON representative for details.  
Do not apply a force of 19.6 N or higher to the pin plunger.  
Exercise care that the environment conditions such as temperature  
and humidity do not change abruptly.  
Micro Load Applicable Range  
Using a model for ordinary loads to open or close the contact of a  
micro load circuit may result in faulty contact. Use models that operate  
in the following range. However, even when using micro load models  
within the operating range shown here, if inrush current occurs when  
the contact is opened or closed, it may increase contact wear and so  
decrease durability. Therefore, insert a contact protection circuit  
where necessary.  
The minimum applicable load is the N-level reference value. This  
value indicates the malfunction reference level for the reliability level  
of 60% (λ 60). The equation, λ 60 = 0.5×10-6/operations indicates that  
the estimated malfunction rate is less than 1/2,000,000 operations  
with a reliability level of 60%.  
Split-contact Switch (Z-10F@Y)  
The applicable current varies depending on how the contacts are  
used. If the Switch is connected in series, the Switch can endure a  
current 1.5 to 2 times higher than the current that can be applied in  
parallel connection.  
5 mW  
800 mW  
Flexible Rod Switch (Z-15@NJ@55, Drip-proof)  
When the rod is fully swung, the Switch may operate when the lever  
returns, causing chattering. Use a circuit that compensates for  
chattering wherever possible.  
Do not switch the rod to the fullest extent when the Switch is to  
break a power circuit because such a practice may cause metal  
deposition to occur between the mating contacts of the Switch.  
0.16 mA  
26 mA  
30  
24  
Operating  
range for  
general load  
models  
Z-15H, H2  
Z-15G  
Z-15E  
Z-10FY  
Z-15ER  
Operating range  
for micro load  
models Z-01H  
12  
Other Precautions  
Unusable  
range  
Do not apply excessive force with a screwdriver or other tool when  
attaching or removing the Protective Cover. Doing so may deform  
the Switch.  
5
0
1 mA  
100 mA 160 mA  
0.1  
1
10  
100  
1,000  
Current (mA)  
Screwdriver  
Z-01H  
Z-15@, Z-10FY  
Minimum applicable  
load  
1 mA at 5 VDC  
160 mA at 5 VDC  
The Drip-proof Terminal Protective Cover can be sued only with  
Switches with model numbers ending in “-B5V.”  
Only the Terminal Protective Cover is available for maintenance.  
27  
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2016.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2016 All Right Reserved.  

相关型号:

Z-15GA55-B5V

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD-5-B7

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD-B

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD-B7

ENDLAGENSCHALTER NACHLAUFSTOESSEL KURZ

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Z-15GD-B7-K

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD-K

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD55

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD55-B

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD55-B-ND

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD55-B7-K

General-purpose Basic Switch

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Z-15GD55-M19R 1M

SWTCH SPDT 15A SHORT SPRNG PLNGR

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON