ZC-W55 [OMRON]

Small, High-precision ENclosed Switch; 小型,高精度封闭式开关
ZC-W55
型号: ZC-W55
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Small, High-precision ENclosed Switch
小型,高精度封闭式开关

开关
文件: 总8页 (文件大小:500K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Enclosed Switch  
ZC-@55  
CSM_ZC-_55_DS_E_2_1  
Small, High-precision Enclosed Switch  
Small, High-precision Enclosed Switches with Built-in Basic  
Switches for High Repeatability and Durability of 10 Million  
Operations Minimum.  
Same mounting pitch as Z Basic Switch.  
Requires less operating force than conventional limit switches.  
Lineup includes modes with operation indicators for easy  
maintenance and inspection.  
Approved by EN, UL, CSA, and CCC (Chinese standard).  
(Ask your OMRON representative for Information on approved  
models.)  
Be sure to read Safety Precautions on page 7 and  
Safety Precautions for All Limit Switches.  
Model Number Structure  
Model Number Legend  
W: Short hinge lever  
W1: Hinge lever  
W2: Short hinge roller lever  
W21: Hinge roller lever  
W3: One-way action short hinge roller lever  
W31: One-way action hinge roller lever  
(1) Actuator  
ZC-@55  
D: Plunger  
Q: Panel mount plunger  
(1)  
Q22: Panel mount roller plunger  
Q21: Panel mount crossroller plunger  
N22: Sealed roller plunger  
N21: Sealed crossroller plunger  
Ordering Information  
Approved Standards  
Actuator  
Model  
UL  
CSA  
EN  
ZC-D55  
Plunger  
Panel mount  
plunger  
ZC-Q55  
Panel mount  
roller plunger  
ZC-Q2255  
ZC-Q2155  
ZC-N2255  
ZC-N2155  
ZC-W55  
Panel mount  
crossroller plunger  
Sealed roller  
plunger  
Sealed crossroller  
plunger  
Short hinge  
lever  
ZC-W155  
ZC-W255  
ZC-W2155  
Hinge lever  
Short hinge  
roller lever  
Hinge roller  
lever  
Note: 1. Use molded terminal models when using the  
Switch under one of the following conditions:  
a) dusty, b) high amount of dripping oil, or c)  
high humidity.  
One-way action  
short hinge roller  
lever  
ZC-W355  
2. Models are available with lead outlets in three  
positions: right-hand, left-hand, and underside.  
One-way action  
hinge roller lever  
ZC-W3155  
1
ZC-@55  
Specifications  
Approved Standards  
Agency  
Standard  
File No.  
E76675  
UL*  
UL508  
TÜV Rheinland  
CCC(CQC)  
EN60947-1, EN60947-5-1  
GB14048.5  
J50041904  
2003010303077620  
Note: Ask your OMRON representative for information on approved models.  
* UL certified for CSA C22.2 No. 14.  
Ratings  
Approved Standard Ratings  
UL/CSA  
Non-inductive load (A)  
Resistive load Lamp load Inductive load Motor load  
NC NO NC NO NC NO NC NO  
1.5 10 2.5  
1.25 10  
Inductive load (A)  
Rated  
voltage  
A300  
Volt-amperes  
(VA)  
Current (A)  
Carry  
current  
Voltage  
125 VAC 10  
250 VAC 10  
3
2.5  
5
Make  
Break  
Make  
Break  
3
1.5  
120 VAC  
240 VAC  
60  
30  
6
3
8 VDC 10  
14 VDC 10  
3
3
3
0.4  
0.2  
1.5  
1.5  
1.5  
0.4  
0.2  
6
6
5
0.05  
0.03  
5
5
5
2.5  
2.5  
2.5  
10A  
7,200  
720  
30 VDC  
6
TÜVRheinland (EN60947-1, EN60947-5-1),  
CCC (GB14048.5)  
125 VDC 0.5  
250 VDC 0.25  
0.05 0.05  
0.03 0.03  
Applicable category and ratings  
AC-12 10 A/250 VAC  
NC  
NO  
30 A max.  
15 A max.  
Inrush  
current  
Note: 1. The above figures are for steady-state currents.  
2. Inductive loads have a power factor of 0.4 min. (AC) and a time  
constant of 7 ms max. (DC).  
3. Lamp load has an inrush current of 10 times the steady-state current.  
4. Motor load has an inrush current of 6 times the steady-state current.  
5. The above ratings were tested under the following conditions  
according.  
(1) Ambient temperature:+20 2°C  
(2) Ambient humidity: 65 5%RH  
(3) Operating frequency:20 operations/min.  
Characteristics  
Engineering Data  
Electrical Durability  
Degree of protections  
IP67  
10,000  
7,000  
5,000  
Mechanical  
Durability  
10,000,000 operations min.  
500,000 operations min.  
0.05 mm/s to 0.5 m/s *1  
120 operations/min  
20 operations/min  
Electrical  
125 VAC cosφ=1  
Operating speed  
3,000  
125 VAC cosφ=0.4  
Mechanical  
Electrical  
Operating  
frequency  
250 VAC cosφ=1  
1,000  
700  
500  
250 VAC cosφ=0.4  
Insulation resistance  
100 Mmin. (at 500 VDC)  
15 mmax. (initial value for the built-  
in switch when tested alone)  
300  
Contact resistance  
Between non-continu-  
ous terminals  
1,000 VAC, 50/60 Hz for 1 min  
100  
70  
50  
Dielectric  
strength  
Between each terminal  
and non-current-carry- 2,000 VAC, 50/60 Hz for 1 min  
Operating temperature: +20 2°C  
Operating humidity: 65 5%RH  
30  
ing metal parts  
Operating frequency: 20 operations/min  
Rated insulation voltage (Ui)  
1,000 VAC  
10  
0
Pollution degree  
(operating environment)  
2
4
6
8
10  
12  
3 (IEC947-5-1)  
Switching current (A)  
Short-circuit protective device  
Protection against electric shock  
Proof tracking index (PTI)  
Switch category  
10 A-fuse type gG (IEC 60269)  
Class II  
175  
Mechanical Durability (for ZC-Q55)  
10,000  
7,000  
5,000  
D (IEC335)  
10 A  
Rated operating current (Ie)  
Rated operating voltage (Ue)  
3,000  
250 VAC  
Vibration  
10 to 55 Hz, 1.5-mm double ampli-  
tude *2  
1,000 m/s2 max.  
300 m/s2 max.  
Malfunction  
resistance  
1,000  
700  
500  
Destruction  
Shock  
resistance  
300  
Malfunction  
(in case of plunger model) *1 *2  
Ambient operating temperature  
Ambient operating humidity  
10°C to +80°C (with no icing)  
35% to 95%RH  
100  
70  
50  
Approx. 92 g (in case of ZC-  
Q22(21)55)  
Operating temperature: +20 2˚C  
Operating humidity: 65 5%RH  
No load  
Weight  
30  
*1. Only for models with plungers. (Contact your OMRON representative for  
information on other models.)  
*2. Less than 1 ms under a free state at the operating limits.  
Operating frequency: 120 operations/min  
0.3 0.50.7 7 10  
OT (mm)  
0
0.1  
1
3
5
2
ZC-@55  
Structure and Nomenclature  
Structure  
Contact Form  
Changing the Terminal Protective Cover around allows the cable to  
be pulled out from either the right or the left.  
(COM)1  
2(NC)  
4(NO)  
Roller  
Plunger  
Case  
NC fixed contact  
Moving contact  
Switch  
NO fixed contact  
Seal rubber  
Packing  
Terminal Protective  
Cover  
Common  
terminal  
(COM)  
Normally  
closed terminal (NC)  
terminal (NO)  
Normally  
open  
Note: M4 binding head screws (with toothed washers) are used as the terminal screws.  
Dimensions and Operating Characteristics  
(Unit: mm)  
Plunger  
ZC-D55  
Panel Mount Plunger  
7.8 dia.*1  
ZC-Q55  
53.4  
23.3  
A
PT  
53.4  
14 dia.  
Two M14 × 1  
hexagon nuts *3  
A
PT  
23.3  
7.8 dia.  
14  
*
*2  
12.5  
14  
8
OP  
21  
OP  
21  
5
19  
19  
5
(10)  
(10)  
18.3  
22 max.  
18.3  
22 max.  
0.15  
0.15  
25.4  
25.4  
(21  
× 21)  
15  
15  
(21 ×  
55  
55  
21.7  
Terminal Protective Cover  
*Stainless steel plunger  
Two, 4.3 0.1 dia.  
mounting holes  
Terminal protective cover  
*1. Stainless steel plunger  
Two, 4.3 0.1 dia.  
mounting holes  
21.7  
Seal rubber  
(NBR)  
(NBR)  
*2. The length of the imperfect threads is 1.5 mm maximum.  
*3. Thickness: 3 width: 17  
Note: Do not use the M14 mounting  
screw and the case mounting  
hole at the same time.  
Panel Mount Roller Plunger  
ZC-Q2255  
Panel Mount Crossroller Plunger  
11 dia. × 4.7 *1  
53.4  
23.3  
Set position  
53.4  
23.3  
ZC-Q2155  
11 dia. × 4.7 *1  
A
indication line  
PT  
A
PT  
14  
Set position indication line  
Two M14 × 1  
(3.6)  
(3.6)  
Two M14 × 1  
hexagon nuts  
hexagon nuts  
*3  
*3  
(2.25)  
(2.25)  
*2  
12.5  
21  
*2  
14  
12.5  
OP  
OP  
19  
21  
19  
5
5
(10)  
(10)  
18.3  
22 max.  
18.3  
22 max.  
0.15  
25.4  
0.15  
25.4  
15  
(21 × 21)  
15  
(21 × 21)  
55  
Terminal protective cover  
Two, 4.3 0.1 dia.  
mounting holes  
21.7  
Seal rubber  
(NBR)  
55  
21.7  
Seal rubber  
(NBR)  
Terminal protective cover  
Two, 4.3 0.1 dia.  
mounting holes  
*1. Stainless sintered alloy roller  
*2. The length of the imperfect threads is 1.5 mm maximum.  
*3. Thickness: 3 width: 17  
*1. Stainless sintered alloy roller  
*2. The length of the imperfect threads is 1.5 mm maximum.  
*3. Thickness: 3 width: 17  
Note: Do not use the M14 mounting  
screw and the case mounting  
hole at the same time.  
Note: Do not use the M14 mounting  
screw and the case mounting  
hole at the same time.  
Sealed Roller Plunger  
Sealed Crossroller Plunger  
ZC-N2155  
ZC-N2255  
9.5 dia. × 4.7 *  
53.4  
23.3  
53.4  
23.3  
Rubber boot  
(chloroprene rubber)  
9.5 dia. × 4.7 *  
Rubber boot  
(chloroprene rubber)  
A
A
PT  
PT  
14  
14  
OP  
OP  
19  
19  
5
5
(10)  
(10)  
18.3  
22 max.  
18.3  
22 max.  
0.15  
0.15  
25.4  
25.4  
15  
(21 ×  
21)  
15  
(21  
×
21)  
55  
55  
21.7  
Two, 4.3 0.1 dia.  
mounting holes  
21.7  
Seal rubber  
(NBR)  
Seal rubber  
(NBR)  
Terminal protective cover  
Two, 4.3 0.1 dia.  
mounting holes  
Terminal protective cover  
*
Stainless sintered alloy roller  
*
Stainless sintered alloy roller  
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
2. Operating characteristics are for when the Switch is operated from direction A.  
3
ZC-@55  
Short Hinge Roller Lever  
ZC-W55  
Hinge Lever  
ZC-W155  
53.4  
34.6  
53.4  
34.6  
14  
14  
t=1  
*
70R  
t=1  
*
A
A
8
50R  
8
FP  
FP  
OP  
OP  
22.5  
5
20  
22.5  
5
20  
(10)  
(10)  
18.3  
22 max.  
18.3  
22 max.  
0.15  
25.4  
0.15  
25.4  
15  
(21 × 21)  
15  
(21 × 21)  
55  
Terminal protective cover  
Stainless steel lever  
Two, 4.3 0.1 dia.  
mounting holes  
21.7  
Seal rubber  
(NBR)  
55  
21.7  
Seal rubber  
(NBR)  
Terminal protective cover  
Stainless steel lever  
Two, 4.3 0.1 dia.  
mounting holes  
*
*
Short Hinge Roller Lever  
ZC-W255  
Hinge Roller Lever  
ZC-W2155  
53.4  
34.6  
53.4  
34.6  
A
14  
14  
12.7 dia. × 7.5 *2  
12.7 dia. × 7.5 *2  
A
t=1 *1  
t=1 *1  
70R  
50R  
FP  
FP  
OP  
OP  
22.5  
5
22.5  
5
20  
20  
(10)  
(10)  
18.3  
22 max.  
18.3  
22 max.  
0.15  
0.15  
25.4  
25.4  
15  
(21 × 21)  
15  
(21 × 21)  
55  
55  
Two, 4.3 0.1 dia.  
mounting holes  
Terminal protective cover  
Two, 4.3 0.1 dia.  
mounting holes  
21.7  
21.7  
Seal rubber  
(NBR)  
Seal rubber  
(NBR)  
Terminal protective cover  
*1. Stainless steel lever  
*2. Stainless steel roller  
*1. Stainless steel lever  
*2. Stainless steel roller  
One-way Action Short Hinge Roller Lever  
One-way Action Hinge Roller Lever  
Operating direction  
ZC-W355  
ZC-W3155  
Operating direction  
53.4  
53.4  
34.6  
14  
12.7 dia. × 7.5 *2  
34.6  
14  
12.7 dia. × 7.5 *2  
A
A
Angle of roller  
swing: 90  
°
Angle of roller  
swing: 90  
73R  
°
54R  
t=1 *1  
t=1 *1  
FP  
FP  
OP  
OP  
22.5  
5
22.5  
5
20  
20  
(10)  
(10)  
18.3  
22 max.  
18.3  
22 max.  
0.15  
0.15  
25.4  
25.4  
15  
(21 × 21)  
15  
(21 × 21)  
55  
21.7  
Terminal protective cover  
Two, 4.3 0.1 dia.  
mounting holes  
21.7  
Seal rubber  
(NBR)  
55  
Seal rubber  
(NBR)  
Terminal protective cover  
Two, 4.3 0.1 dia.  
mounting holes  
*1. Stainless steel lever  
*2. Stainless steel roller  
*1. Stainless steel lever  
*2. Stainless steel roller  
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
2. Operating characteristics are for when the Switch is operated from direction A.  
Operating Characteristics  
Model  
OF max.  
RF min.  
ZC-D55  
ZC-Q55  
ZC-Q2255  
ZC-Q2155  
ZC-N2255 *  
ZC-N2155 *  
Operating force  
Release force  
Pretravel  
11.8 N  
4.9 N  
1.5 mm  
2.4 mm  
0.2 mm  
11.8 N  
4.9 N  
1.5 mm  
3 mm  
11.8 N  
4.9 N  
1.5 mm  
3 mm  
11.8 N  
4.9 N  
1.5 mm  
3 mm  
6.86 N  
1.67 N  
1.5 mm  
2.5 mm  
0.2 mm  
6.86 N  
1.67 N  
1.5 mm  
2.5 mm  
0.2 mm  
PT max.  
OT min.  
Overtravel  
Movement Differential MD max.  
0.2 mm  
0.2 mm  
0.2 mm  
Free Position  
Operating Position  
FP  
OP  
---  
---  
---  
---  
---  
---  
max.  
32.4 0.8 mm  
38.2 0.8 mm  
47.4 0.8 mm  
47.4 0.8 mm  
47.4 0.8 mm  
47.4 0.8 mm  
* Make sure that the permissible OT position is not exceeded.  
Operating Characteristics  
Model  
OF max.  
RF min.  
ZC-W55  
ZC-W155  
ZC-W255  
ZC-W2155  
ZC-W355  
ZC-W3155  
Operating force  
Release force  
Pretravel  
3.92 N  
0.78 N  
---  
6 mm  
1 mm  
2.75 N  
0.59 N  
---  
8.4 mm  
1.4 mm  
3.92 N  
0.78 N  
---  
6 mm  
1 mm  
2.75 N  
0.59 N  
---  
8.4 mm  
1.4 mm  
3.92 N  
0.78 N  
---  
6 mm  
1 mm  
2.75 N  
0.59 N  
---  
8.4 mm  
1.4 mm  
PT max.  
OT min.  
Overtravel  
Movement Differential MD max.  
Free Position  
Operating Position  
FP  
OP  
34.7 mm  
28.5 1.2 mm  
36.7 mm  
28.5 1.2 mm  
49.2 mm  
43 1.2 mm  
51.3 mm  
43 1.2 mm  
59.2 mm  
53 1.2 mm  
61.2 mm  
53 1.2 mm  
max.  
4
ZC-@55  
Molded Terminal Models  
(Not Approved by UL, CSA, or EN)  
Use of the molded terminal model is recommended in locations  
subject to excessive dust, oil drips, or moisture.  
All types of ZC Switches can be fabricated into a molded terminal  
version. In this case, the molded terminal model will have the same  
dimensions and operating characteristics as the basic model from  
which the molded terminal model is fabricated.  
Terminal Protective Cover, Seal Rubber, and  
Rubber Packing  
(The Switch is equipped with these 3 items as a  
standard.)  
ZC Terminal Cover  
(Product code: ZC55-0002H)  
ZC Seal Rubber  
(Product code: SC-1404C)  
ZC Rubber Packing  
(Product code: ZC55-0003F)  
Suffix by Location of Lead Outlet  
Model (Suffix)  
COM, NC, NO  
-MR  
Location of  
lead output  
Note: The suffixes on the  
left can be added to  
the model numbers  
given on page 1 to  
specify molded  
Right-hand  
Left-hand  
Underside  
-ML  
-MD  
terminals.  
Lead Supplies  
Nominal  
Speci-  
Leads fica-  
tion  
External  
diameter  
(mm)  
Terminal  
Length  
cross-sectional  
area  
connec-  
(
m)  
tions  
2
(mm )  
V.C.T.  
(vinyl  
cabtire  
cable)  
Black:  
3 conductor: COM  
10.5 dia. White: NO  
Red: NC  
1.25  
1, 3  
Note: When placing your order for the Switch, specify the required length of  
V.C.T. cable in addition to the model number of the Switch.  
Consult with your OMRON representative for other types of lead wires  
and for lead wires longer than 3 m.  
How to Order  
Example:  
Standard type:  
ZC-Q2255  
Location of lead output:Right side  
Length of lead:  
1 m (V.C.T. lead)  
When placing your order for the above Switch, specify the model  
number as ZC-Q2255-MR VCT 1M.  
5
ZC-@55  
Operation Indicator-equipped Models (Not Approved by UL, CSA, or EN)  
All the models can be equipped upon request with a operation indicator to facilitate maintenance and inspection.  
Because the indicator is incorporated in the Terminal Protective Cover, the dimensions of the Limit Switch are not affected. In this model, the  
lead wire is to be connected to the screw terminal. (A connecting washer is provided on the tip of the lead wire).  
The lead wire can be connected to either the NC or NO terminal.  
Operating characteristics are the same as the standard model from which the operation indicator equipped model is fabricated.  
(For AC)  
(For DC)  
The operating voltage range is from 90 to 250 VAC.  
The dimensions are the same as the standard type. The top of the  
Terminal Protective Cover is transparent to allow checking the  
operation easily.  
The DC-operated is provided with an LED indicator.  
There is no protective structure.  
Since a rectifier stack is incorporated into the unit to permit reversing  
the polarity, this type can also operate on AC power source.  
When placing your order for the indicator equipped, AC-operated  
model, add suffix "L" to the end of the model number.  
Example:  
The LED projects from the housing for easy visibility.  
When placing your order, add suffix "L2" or "L4" to the model number of the standard type.  
Example:  
Standard type:  
ZC-Q2255  
Standard type:  
ZC-Q2255  
Indicator equipped type: ZC-Q2255-L  
Indicator equipped type: ZC-Q2255-L2  
Contact Circuit  
Leakage current  
(mA)  
Internal  
resistance (k)  
Model  
Voltage rating (V)  
Power supply  
Neon lamp  
L2  
L4  
12  
24  
Approx.2.4  
Approx.1.2  
4.3  
18  
R = 240 kΩ  
Contact Circuit  
NC terminal  
Power supply  
LED  
Load  
Built-in switch  
Resistor  
NC terminal  
Power supply  
Built-in switch  
Load  
NO terminal  
Load  
Built-in switch  
Power supply  
Built-in switch  
R = 240 kΩ  
Neon lamp  
Note: If the wiring is as shown above, the operation of the respective parts will  
be as shown in the following table. The neon lamp is not wired when the  
Switch is delivered. Connect it as required.  
Load  
NO terminal  
Contact  
NC  
Neon lamp  
ON  
Load  
Actuator  
Operates  
Does not operate  
Operates  
Resistor  
LED  
OFF  
Does not operate  
Does not operate  
Operates  
ON  
Does not operate  
Operates  
NO  
OFF  
Note: If the wiring is as shown above, the operation of the respective parts will  
be as shown in the following table. The LED terminals are not wired when  
the Switch is delivered. Connect it as required.  
Contact  
NC  
LED  
ON  
Load  
Does not operate  
Operates  
Actuator  
Operates  
OFF  
ON  
Does not operate  
Does not operate  
Operates  
Does not operate  
Operates  
NO  
OFF  
6
ZC-@55  
Safety Precautions  
Refer to Safety Precautions for All Limit Switches.  
Precautions for Correct Use  
Operating Environment  
Micro Load Models  
Seal material may deteriorate if a Switch is used outdoor or where  
subject to special cutting oils, solvents, or chemicals. Always  
appraise performance under actual application conditions and set  
suitable maintenance and replacement periods.  
Install Switches where they will not be directly subject to cutting  
chips, dust, or dirt. The Actuator and Switch must also be protected  
from the accumulation of cutting chips or sludge.  
Contact failure may occur is a General-purpose Switch is used to  
switch a microload circuit. Use Switches within the areas shown in the  
following chart. Even when using Microload Switches within the area  
shown below, contact wear will become more extreme with loads that  
generate surge current when switching and durability will be  
adversely affected. If necessary, insert a contact protective circuit.  
Microloads are indicated by N standard reference values. This value  
represents the failure rate at a 60% (λ60) reliability level. (JIS C5003)  
The equation λ60 = 0.5 × 106/operations indicates that a failure rate  
of 1/2,000,000 operations can be expected at a reliability level of 60%.  
Not Suitable  
Suitable  
0.8 W  
26 mA 100 mA  
30  
Constantly subjecting a Switch to vibration or shock can result in  
wear, which can lead to contact interference with contacts,  
operation failure, reduced durability, and other problems.  
Excessive vibration or shock can lead to false contact operation or  
damage. Install Switches in locations not subject to shock and  
vibration and in orientations that will not produce resonance.  
The Switches have physical contacts. Using them in environments  
containing silicon gas will result in the formation of silicon oxide  
(SiO2) due to arc energy. If silicon oxide accumulates on the  
contacts, contact interference can occur. If silicon oil, silicon filling  
agents, silicon cables, or other silicon products are present near the  
Switch, suppress arcing with contact protective circuits (surge  
killers) or remove the source of silicon gas.  
24  
Applicable  
Applicable area  
for Microload  
Models  
area for  
General-  
purpose  
Models  
(ZC-@55-01)  
(ZC-@55)  
12  
Not  
applicable  
5
0
1 mA  
1
100 mA 160 mA  
0.1  
10  
100  
1,000  
Current (mA)  
Dog Angle  
Model  
ZC-@55-01  
ZC-@55  
5 VDC 160mA  
When operating the roller type, be sure to set the dog angle to less than  
Minimum applicable  
load  
30  
°
(even when operating at a low speed). Operating the model at a dog  
will soon cause abrasion or damage. Do not apply a  
5 VDC 1mA  
angle exceeding 30  
°
twisting force to the plunger. Set the OT to 70% to 100% of the specified  
value so that the actuator will not exceed the OT.  
Mounting  
When mounting the Switch with  
screws on a side surface, fasten the  
Switch with M4 screws and use  
washers, spring washers, etc., to  
ensure secure mounting.  
Mounting Holes  
Handling  
Two, 4.3-dia. or M4 screw holes  
When detaching the Terminal  
Protective Cover, insert a  
screwdriver and apply a force  
in the opening direction. Do  
not use excess force to  
remove the cover. Doing so  
may cause deformation in the  
fitting section and reduce the  
holding force.  
0.15  
25.4  
When mounting the Panel Mount-  
type Enclosed Switch (ZC-Q55, ZC-  
Q2255, or ZC-Q2155) with screws  
on a side surface, remove the  
Mounting Holes  
14.5+0.2 dia.  
0
hexagonal nuts from the actuator.  
When mounting the Terminal  
Protective Cover to the case,  
align the cover on the case and then press the cover down to mount  
it firmly. If the cover is pressed down in an inclined position, rubber  
packing will deform and thus affect the sealing capability.  
Appropriate Tightening Torque  
A loose screw may result in a malfunction. Be sure to tighten each  
screw to the proper tightening torque as shown below.  
Appropriate Tightening  
No.  
Type  
Torque  
(1) Terminal screw  
(2) Panel mounting screw  
(3) Side mounting screw  
0.78 to 1.18 N·m  
4.90 to 7.84 N·m  
1.18 to 1.47 N·m  
Operation  
With the ZC-Q22(21)55, an  
Rubber packing  
Rubber packing  
appropriate OT line is marked on  
the plunger. Set the OT so that it is  
between the two X-surface lines.  
A 8.5-dia. to 10.5-dia. cable can be applied as seal rubber for the  
lead wire outlet. (Use two- or three-core cable of VCT1.25 mm2.)  
Use weather-proof rubber (chloroprene rubber) as seal rubber for  
the ZC-N22(21)55.  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

ZC0201

THICK FILM CHIP RESISTORS AND JUMPERS
RCD

ZC0201P

THICK FILM CHIP RESISTORS AND JUMPERS
RCD

ZC0201U

THICK FILM CHIP RESISTORS AND JUMPERS
RCD

ZC0204BKC13590

Fixed Resistor, Metal Film, 0.25W, 590ohm, 0.1% +/-Tol, 15ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204BKD13402

Fixed Resistor, Metal Film, 0.25W, 402ohm, 0.1% +/-Tol, 25ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204BKD13453

Fixed Resistor, Metal Film, 0.25W, 453ohm, 0.1% +/-Tol, 25ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204BKD13510

Fixed Resistor, Metal Film, 0.25W, 510ohm, 0.1% +/-Tol, 25ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204BKD13511

Fixed Resistor, Metal Film, 0.25W, 511ohm, 0.1% +/-Tol, 25ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204BKD1351K0

Fixed Resistor, Metal Film, 0.25W, 51000ohm, 0.1% +/-Tol, 25ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204BKD1351R0

Fixed Resistor, Metal Film, 0.25W, 51ohm, 0.1% +/-Tol, 25ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204CKC13115

Fixed Resistor, Metal Film, 0.25W, 115ohm, 0.25% +/-Tol, 15ppm/Cel, Surface Mount, 1406, MELF
YAGEO

ZC0204CKD13402

Fixed Resistor, Metal Film, 0.25W, 402ohm, 0.25% +/-Tol, 25ppm/Cel, Surface Mount, 1406, MELF
YAGEO