ZE-Q-2S [OMRON]

General-purpose Enclosed Switches with High Breaking Capacity and High Durability; 通用封闭式开关与高分断能力和高耐用性
ZE-Q-2S
型号: ZE-Q-2S
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
通用封闭式开关与高分断能力和高耐用性

开关
文件: 总11页 (文件大小:1644K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Enclosed Switches  
ZE/ZV/ZV2/XE/XV/XV2  
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1  
General-purpose Enclosed  
Switches with High Breaking  
Capacity and High Durability  
Z General-purpose Basic Switches are built into ZE, ZV,  
and ZV2 Switches. They provided high durability and high  
breaking capacity.  
X Basic Switches with magnetic blowout are built into XE,  
XV, and XV2 Switches. DC models have also been added  
to the series.  
Three mounting methods (side, base, and diagonal side)  
and many types of actuator are available.  
Terminals face the front when the cover is removed for  
easy connection.  
Switches with ground terminals have CE marking.  
Approved by UL, CSA, and CCC (Chinese standard).  
(Ask your OMRON representative for information on  
approved models.)  
Be sure to read Safety Precautions on page 8 to 9 and  
Safety Precautions for All Limit Switches.  
Model Number Structure  
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)  
@@-@-2@  
(1)(2) (3)  
(4)  
(1) Built-in Switch  
(3) Actuator  
(4) Conduit/Ground Terminal *  
Z
X
: SPDT (AC)  
: SPDT (DC)  
Q
: Plunger  
None : G 1/2/without ground terminal  
G1 : G 1/2/with ground terminal  
Q22 : Roller plunger  
Q21 : Crossroller plunger  
QA2 : Roller arm lever  
QA277 : One-way action roller arm lever  
G
: Pg13.5/with ground terminal  
(2) Mounting Direction  
SG1 : 1/2-14NPSM/with ground terminal  
YG1 : M20/with ground terminal  
E
V
: Side mounting  
: Base mounting  
N
: Sealed plunger  
S
Y
: 1/2-14NPSM/without ground terminal  
: M20/without ground terminal  
V2 : Diagonal side mounting  
N22 : Sealed roller plunger (ZE, ZV, ZV2 only)  
N21 : Sealed crossroller plunger (ZE, ZV, ZV2 only)  
NA2 : Sealed roller arm lever  
NA277 : Sealed one-way action roller arm lever  
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard  
models.  
1
ZE/ZV/ZV2/XE/XV/XV2  
Ordering Information  
Side mounting  
Base mounting  
Diagonal side mounting  
Mounting  
Approved  
standards  
Approved  
standards  
Approved  
standards  
Actuator  
Model  
Model  
Model  
UL  
CSA  
UL  
CSA  
UL  
CSA  
AC  
DC  
AC  
DC  
AC  
DC  
AC  
DC  
AC  
DC  
AC  
DC  
ZE-Q-2  
ZV-Q-2  
ZV2-Q-2  
Plunger  
XE-Q-2  
XV-Q-2  
ZV-Q22-2  
XV-Q22-2  
ZV-Q21-2  
XV-Q21-2  
ZV-QA2-2  
XV-QA2-2  
---  
XV2-Q-2  
ZV2-Q22-2  
XV2-Q22-2  
ZV2-Q21-2  
---  
ZE-Q22-2  
XE-Q22-2  
ZE-Q21-2  
XE-Q21-2  
ZE-QA2-2  
XE-QA2-2  
ZE-QA277-2  
XE-QA277-2  
ZE-N-2  
Roller plunger  
General  
Crossroller plunger  
purpose  
ZV2-QA2-2  
XV2-QA2-2  
ZV2-QA277-2  
---  
Roller arm lever  
One-way action roller  
arm lever  
---  
ZV-N-2  
XV-N-2  
ZV2-N-2  
XV2-N-2  
Sealed plunger  
XE-N-2  
Sealed roller plunger  
AC  
AC  
ZE-N22-2  
ZE-N21-2  
ZV-N22-2  
ZV-N21-2  
ZV2-N22-2  
ZV2-N21-2  
Sealed crossroller  
plunger  
Sealed  
(Booted)  
AC  
DC  
AC  
DC  
ZE-NA2-2  
ZV-NA2-2  
XV-NA2-2  
ZV-NA277-2  
---  
ZV2-NA2-2  
Sealed roller arm lever  
XE-NA2-2  
XV2-NA2-2  
ZE-NA277-2  
XE-NA277-2  
ZV2-NA277-2  
XV2-NA277-2  
One-way action  
sealed roller arm lever  
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with  
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.  
2. Ask your OMRON representative for information on models with ground terminals.  
Specifications  
Approved Standards  
Agency  
Standard  
UL508  
File No.  
E76675  
UL  
CSA  
CSA C22.2 No.14  
GB14048.5  
LR45746  
CCC (CQC)  
2003010303077623  
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.  
2. Ask your OMRON representative for information on approved models.  
Ratings  
Non-inductive load (A)  
Resistive load Lamp load  
NC NO NC NO  
Inductive load (A)  
Inductive load Motor load  
NC NO  
NC  
NO  
30 A max.  
15 A max.  
Inrush  
current  
Rated  
voltage  
Model  
NC  
NO  
125 VAC  
250 VAC  
480 VAC  
15  
15  
10  
3
2.5  
1.5  
1.5  
1.25  
0.75  
15  
15  
6
5
3
1.5  
2.5  
1.5  
0.75  
ZE-@  
ZV-@  
ZV2-@  
125 VDC  
250 VDC  
0.5  
0.25  
0.5  
0.25  
0.05  
0.03  
0.05  
0.03  
Note: 1. The above figures are for standard currents.  
2. Inductive loads have a power factor of 0.4 min.  
(AC) and a time constant of 7 ms max. (DC).  
3. Lamp load has an inrush current of 10 times  
the steadystate current.  
8 VDC  
10  
10  
10  
10  
3
3
3
3
3
1.5  
1.5  
1.5  
1.5  
0.75  
10  
10  
10  
7.5  
2
10  
10  
10  
6
5
5
5
2
2
2.5  
2.5  
2.5  
2.5  
1.5  
XE-@  
XV-@  
XV2-@  
14 VDC  
30 VDC  
125 VDC  
250 VDC  
1.5  
1.5  
4. Motor load has an inrush current of 6 times the  
steady-state current.  
2
ZE/ZV/ZV2/XE/XV/XV2  
Approved Standard Ratings  
UL/CSA  
Characteristics  
Degree of protection  
IP65*1  
Z@: 10,000,000 operations min.  
Model  
Rated voltage  
Current  
Horsepower  
Mechanical  
X@: 1,000,000 operations min.  
125 VAC  
250 VAC  
480 VAC  
15 A  
15 A  
15 A  
Durability  
* 2  
1/8HP  
1/4HP  
Z@: 500,000 operations min., for 15 A,  
250 VAC resistive load  
X@: 100,000 operations min., for 10 A,  
125 VDC resistive load  
Electrical  
ZE  
125 VDC  
250 VDC  
0.5 A  
0.25 A  
---  
Plunger type: 0.01 mm/s to 0.5 m/s  
Lever type: 0.02 mm/s to 0.5 m/s  
Operating speed  
CCC (GB14048.5)  
Mechanical  
Electrical  
Rated frequency  
Insulation resistance  
Contact resistance  
Terminal temperature rise  
120 operations/min  
20 operations/min  
50/60 Hz  
Operating  
frequency  
Applicable category and ratings  
AC-12 10 A/250 VAC  
100 Mmin. (at 500 VDC)  
15 mmax. (initial value)  
50°C max.  
Between terminals  
of the same polarity  
1,000 VAC, 50/60 Hz for 1 min  
Between current-  
carrying metal  
Z@: 2,000 VAC, 50/60 Hz for 1 min  
X@: 1,500 VAC, 50/60 Hz for 1 min  
Dielectric  
part and ground  
strength  
Between each  
terminal and  
Z@: 2,000 VAC, 50/60 Hz for 1 min  
X@: 1,500 VAC, 50/60 Hz for 1 min  
non-current-car-  
rying metal part  
Vibration  
Malfunction  
resistance  
10 to 55 Hz, 1.5-mm double amplitude*3  
1,000m/s2 min.  
Destruction  
Shock  
100 m/s2 min.*4  
resistance  
Malfunction  
*3  
50 m/s2 min.*5  
Ambient operating temperature 10°C to +80°C (with no icing)  
General-purpose type: 35% to 85%RH  
Sealed type: 35% to 95%RH  
Ambient operating humidity  
Weight  
Approx. 260 to 280 g  
Note: The above figures are initial values.  
*1. IP65 for @-N models and IP60 for @-Q models.  
*2. The values are calculated at an operating temperature of +5  
°
C to +35°C, and an  
operating humidity of 40% to 70%RH. Contact your OMRON sales  
representative for more detailed information on other operating environments.  
*3. At the operation limit positions.  
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm  
lever.  
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and  
sealed roller plunger.  
Engineering Data  
Electrical Durability  
ZE (cosφ = 1)  
XE (L/R = 0)  
Operating frequency:  
20 operations/min  
OT: Full stroke  
Operating frequency:  
20 operations/min  
OT: Full stroke  
200  
1,000  
500  
125 VAC  
125 VAC  
250 VAC  
100  
70  
50  
250 VAC  
100  
480 VAC  
50  
0
2
4
6
8
10  
12  
14 16  
0
1
2
3
5
10  
Switching current (A)  
Switching current (A)  
ZE (cosφ = 0.4)  
XE (L/R = 7 ms)  
Operating frequency:  
20 operations/min  
OT: Full stroke  
Operating frequency:  
20 operations/min  
OT: Full stroke  
100  
1,000  
500  
70  
50  
125 VAC  
250 VAC  
125 VAC  
30  
480 VAC  
100  
20  
250 VAC  
50  
0
2
4
6
8
10  
12  
14 16  
0
1
2
3
5
10  
Switching current (A)  
Switching current (A)  
3
ZE/ZV/ZV2/XE/XV/XV2  
Structure and Nomenclature  
Structure  
ZE-NA2-2  
Contact Form  
COM  
NC  
NO  
Pin plunger  
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the  
Tightening band  
Case  
+ terminal.  
Rubber cap (CR)  
Separator  
Built-in switch  
Terminal  
Conduit  
opening  
Cover Seal rubber (NBR)  
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"  
accompanying the JIS B 0202 revision. This changes applies only to the  
indication; thread sizes and pitches have not been affected.  
Dimensions and Operating Characteristics  
(Unit: mm)  
Side Mounting Models  
Plunger  
Roller Plunger  
12.7 dia. × 4.8 *  
JIS B0202 G1/2  
PT  
12R  
*
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
PT  
ZE-Q-2  
XE-Q-2  
ZE-Q22-2  
XE-Q22-2  
Effective thread:  
4 threads min.  
17  
17  
Two, M4  
(length: 45)  
OP  
Two, M4  
(length: 45)  
OP  
19  
19  
25.5  
23  
25.5  
23  
2.1 0.1  
24  
2.1 0.1  
24  
25.4 0.3  
25.4 0.3  
25.4 0.12  
25.4 0.12  
86  
86  
* Stainless steel plunger  
* Stainless steel roller  
19.1 dia. × 7.9 *1  
*2  
Crossroller Plunger  
Roller Arm Lever  
39.7  
12.7 dia. × 4.8 *  
ZE-Q21-2  
XE-Q21-2  
ZE-QA2-2  
XE-QA2-2  
PT  
(23.1)  
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
17  
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
PT  
17  
wo, M4  
ength: 45)  
44 0.8  
OP  
Two, M4  
(length: 45)  
19.3  
19  
19  
25.5  
23  
25.5  
23  
2.1 0.1  
24  
2.1 0.1  
24  
25.4 0.3  
25.4 0.3  
25.4 0.12  
25.4 0.12  
86  
*1. Stainless sintered roller  
*2. Adjustable between 0° and 225°  
86  
* Stainless steel roller  
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)  
Operating  
characteristics  
Model  
ZE-Q-2  
XE-Q-2  
ZE-Q22-2  
XE-Q22-2  
ZE-Q21-2  
XE-Q21-2  
ZE-QA2-2  
XE-QA2-2  
6.47 N max.  
1.67 N  
6 mm  
5.5 mm  
0.72 mm  
Operating force  
Release force  
Pretravel  
Over Travel  
Movement Differential MD max.  
OF  
2.45 to 3.43 N 5.00 N max. 2.45 to 3.43 N 5.00 N max. 2.45 to 3.43 N 5.00 N max.  
5.59 N max.  
1.67 N  
4 mm  
6 mm  
0.4 mm  
RF min.  
PT max.  
OT min.  
1.12 N  
0.4 mm  
5.5 mm  
0.05 mm  
1.12 N  
0.9 mm  
5.5 mm  
0.47 mm  
1.12 N  
0.5 mm  
3.6 mm  
0.05 mm  
1.12 N  
0.9 mm  
3.6 mm  
0.47 mm  
1.12 N  
0.5 mm  
3.6 mm  
0.05 mm  
1.12 N  
0.9 mm  
3.6 mm  
0.47 mm  
Operating Position OP  
38.2 0.8 mm  
49.7 1 mm  
49.7 1 mm  
---  
4
ZE/ZV/ZV2/XE/XV/XV2  
One-way Action Roller Arm Lever  
Sealed Plunger  
ZE-N-2  
ZE-QA277-2  
18.7 dia. × 9 *1  
Operate in this  
direction only  
XE-QA277-2  
XE-N-2  
39.7  
19.3  
*2  
(40)  
17.4R  
PT  
*
12R  
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
PT  
17  
17  
Two, M4  
(length: 45)  
Two, M4  
(length: 45)  
OP  
44 0.8  
19  
19  
25.5  
23  
25.5  
23  
2.1 0.1  
24  
2.1 0.1  
24  
25.4 0.3  
25.4 0.3  
25.4 0.12  
25.4 0.12  
86  
86  
*1. Stainless sintered alloy roller  
*2. Adjustable between 0° and 225°  
* Stainless steel plunger  
Sealed Roller Plunger  
ZE-N22-2  
Sealed Crossroller Plunger  
ZE-N21-2  
12.7 dia. × 4.8 *  
JIS B0202 G1/2  
12.7 dia. × 4.8 *  
PT  
PT  
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
Effective thread:  
4 threads min.  
17  
17  
OP  
OP  
Two, M4  
(length: 45)  
Two, M4  
(length: 45)  
19  
19  
25.5  
25.5  
23  
23  
2.1 0.1  
24  
2.1 0.1  
24  
25.4 0.3  
25.4 0.3  
25.4 0.12  
25.4 0.12  
86  
86  
* Stainless steel roller  
* Stainless steel roller  
Sealed Roller Arm Lever  
ZE-NA2-2  
XE-NA2-2  
One-way Action Sealed Roller Arm Lever  
18.7 dia. × 9 *1  
ZE-NA277-2  
Operate in this  
direction only  
19.1 dia. × 7.9 *1  
XE-NA277-2  
*2  
39.7  
39.7  
*2  
(40)  
17.4R  
(23.1)  
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
JIS B0202 G1/2  
Effective thread:  
4 threads min.  
PT  
PT  
17  
17  
53.4 0.8  
19  
53.4 0.8  
Two, M4  
(length: 45)  
Two, M4  
(length: 45)  
19.3  
19.3  
19  
25.5  
23  
25.5  
23  
2.1 0.1  
24  
2.1 0.1  
24  
25.4 0.3  
25.4 0.3  
25.4 0.12  
25.4 0.12  
86  
86  
*1. Stainless steel roller  
*2. Adjustable between 0° and 225°  
*1. Stainless sintered alloy roller  
*2. Adjustable between 0° and 225°  
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)  
ZE-QA277-2  
XE-QA277-2  
ZE-N-2  
XE-N-2  
ZE-N22-2  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.59 N  
1.67 N  
4 mm  
6 mm  
0.4 mm  
6.47 N  
1.67 N  
6 mm  
5.5 mm  
0.72 mm  
7.85 N  
2.35 N  
2 mm  
5 mm  
0.1 mm  
10.20 N  
2.35 N  
3 mm  
4 mm  
0.47 mm  
4.90 N  
0.98 N  
1 mm  
3.5 mm  
0.12 mm  
OP  
---  
45.8 0.8 mm  
49.7 0.8 mm  
ZE-N21-2  
ZE-NA2-2  
XE-NA2-2  
ZE-NA277-2  
XE-NA277-2  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
4.90 N  
0.98 N  
1 mm  
3.5 mm  
0.12 mm  
6.28 N  
2.26 N  
5 mm  
6 mm  
0.4 mm  
7.26 N  
2.26 N  
6 mm  
5.5 mm  
0.72 mm  
6.28 N  
2.26 N  
5 mm  
6 mm  
0.4 mm  
7.26 N  
2.26 N  
6 mm  
5.5 mm  
0.72 mm  
OP  
49.7 0.8 mm  
---  
---  
5
ZE/ZV/ZV2/XE/XV/XV2  
Base Mounting/Diagonal Side Mounting Models  
The diagrams show the base-mounted model (ZV-@ or XV-@) on top and the diagonal side-mounted model (ZV2-@ or XV2-@) on bottom.  
The flange on base-mounted models is shown with dotted lines.  
Plunger  
ZV(2)-Q-2  
XV(2)-Q-2  
Roller Plunger  
ZV(2)-Q22-2  
XV(2)-Q22-2  
t = 3 (ZV-Q-2/XV-Q-2 flange)  
t = 3 (ZV-Q22-2/XV-Q22-2 flange)  
53R  
53R  
41.3 0.2  
54  
41.3 0.2  
54  
10.5 0.3  
36.6  
10.5 0.3  
36.6  
Two, 4.3 0.2 dia.  
Two, 4.3 0.2 dia.  
JIS B0202 G1/2  
Effective  
thread: 4  
threads min.  
12.7 dia. × 4.8 *1  
JIS B0202 G1/2  
PT  
26.1  
*1  
12R  
PT  
26.1  
Effective  
thread: 4 threads min.  
(see note 2)  
5
17  
17  
(see note 1)  
5
OP  
OP  
31 0.2  
31 0.2  
23  
23  
*2  
3
3
*2  
75 0.2  
86  
75 0.2  
86  
Two, 5.4 +0.2dia.  
5.5  
Two, 5.4 +0.2dia.  
0
0
5.5  
25.4 0.3  
25.4 0.3  
holes  
holes  
*1. Stainless steel plunger  
*2. Only the ZV2-Q-2 and XV2-Q-2 incorporate  
mounting holes.  
*1. Stainless steel roller  
*2. Only the ZV2-Q22-2 and XV2-Q22-2  
incorporate mounting holes.  
Crossroller Plunger  
ZV(2)-Q21-2  
Roller Arm Lever  
ZV(2)-QA2-2  
XV(2)-Q21-2  
XV(2)-QA2-2  
t = 3 (ZV-QA2-2/XV-QA2-2 flange)  
t = 3 (ZV-Q21-2/XV-Q21-2 flange)  
53R  
53R  
41.3 0.2  
54  
54  
41.3 0.2  
10.5 0.3  
10.5 0.3  
36.6  
Two, 4.3 0.2 dia.  
36.6  
Two, 4.3 0.2 dia.  
19.1 dia. × 7.9  
*1  
39.7  
*2  
JIS B0202  
G1/2  
12.7 dia. × 4.8 *1  
JIS B0202 G1/2  
PT  
26.1  
Effective  
thread: 4  
threads min.  
23.1 max.  
PT  
Effective  
thread: 4 threads min.  
(see note 3)  
17  
17  
30 0.8  
19.3  
5
5
OP  
69.5 0.8  
31 0.2  
31 0.2  
23  
23  
3
3
*2  
*3  
75 0.2  
86  
75 0.2  
86  
Two, 5.4 +0.2dia.  
5.5  
Two, 5.4 +0.2dia.  
0
5.5  
0
25.4 0.3  
25.4 0.3  
holes  
holes  
*1. Stainless steel roller  
*2. Only the ZV2-Q21-2 and XV2-Q21-2 incorporate  
mounting holes.  
*1. Stainless sintered roller  
*2. Adjustment between 0° to 225°.  
*3. Only the ZV2-QA2-2 and XV2-QA2-2 incorporate mounting holes.  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
ZV-Q-2  
ZV2-Q-2  
XV-Q-2  
XV2-Q-2  
ZV-Q22-2  
ZV2-Q22-2  
XV-Q22-2  
XV2-Q22-2  
ZV-Q21-2  
ZV2-Q21-2  
XV-Q21-2  
XV2-Q21-2  
ZV-QA2-2  
ZV2-QA2-2  
XV-QA2-2  
XV2-QA2-2  
OF  
2.45 to 3.43 N  
1.12 N  
0.4 mm  
5.5 mm  
0.05 mm  
5.00 N max.  
1.12 N  
0.9 mm  
5.5 mm  
0.47 mm  
2.45 to 3.43 N  
1.12 N  
0.5 mm  
3.6 mm  
0.05 mm  
5.00 N max.  
1.12 N  
0.9 mm  
3.6 mm  
0.47 mm  
2.45 to 3.43 N  
1.12 N  
0.5 mm  
3.6 mm  
0.05 mm  
5.00 N max.  
1.12 N  
0.9 mm  
3.6 mm  
0.47 mm  
5.59 N max.  
1.67 N  
4 mm  
6 mm  
0.4 mm  
6.47 N max.  
1.67 N  
6 mm  
5.5 mm  
0.72 mm  
RF min.  
PT max.  
OT min.  
MD max.  
63.7 0.8 mm (see note 1)  
(ZV-Q-2, XV-Q-2)  
75.2 0.8 mm (see note 2)  
(ZV-Q22-2, XV-Q21-2)  
75.2 0.8 mm (see note 3)  
(ZV-Q22-2, XV-Q21-2)  
OP  
---  
Note: 1. OP for ZV2-Q-2 and XV2-Q-2 is 24.2 0.8 mm.  
2. OP for ZV2-Q22-2 and XV2-Q22-2 is 35.7 1 mm.  
3. OP for ZV2-Q21-2 and XV2-Q21-2 is 35.7 0.8 mm.  
6
ZE/ZV/ZV2/XE/XV/XV2  
One-way Action Roller Arm Lever  
ZV2-QA277-2  
Sealed Plunger  
ZV(2)-N-2  
XV(2)-QA277-2  
XV(2)-N-2  
t=3 (ZV-NA277-2/XV-NA277-2 flanges)  
t = 3 (ZV-N-2/XV-N-2 flange)  
53R  
41.3 0.2  
54  
53R  
41.3 0.2  
54  
10.6 0.3  
Two, 4.3 0.2 dia. holes  
(40)  
18.7 dia. × 9  
36.6  
*1  
10.6 0.3  
Operates in this  
direction only  
*2  
Two, 4.3 0.2 dia. holes  
36.6  
39.7  
JIS B0202 G1/2  
Effective  
R17.4  
thread: 4  
threads min.  
PT  
JIS B0202 G1/2  
Effective  
thread: 4 threads min.  
26.1  
12CR *1  
PT  
19.3  
17  
30 0.8  
5
(see note 1)  
17  
69.5 0.8  
5
31 0.2  
OP  
23  
31 0.2  
3
23  
*2  
*3  
75 0.2  
86  
*1. Stainless steel roller  
*2. Adjustment between 0° to 225°.  
Two, 5.4 +0.2dia.  
5.5  
3
0
25.4 0.3  
holes  
75 0.2  
86  
Two, 5.4 +0.2dia.  
5.5  
25.4 0.3  
0
holes  
*1. Stainless steel plunger  
*2. Only the ZV2-N-2 and XV2-N-2 incorporate mounting holes.  
*3. Only the ZV2-NA277-2 and XV2-NA277-2  
incorporate mounting holes.  
Sealed Roller Plunger  
ZV(2)-N22-2  
Sealed Crossroller Plunger  
ZV(2)-N21-2  
t = 3 (ZV-N22-2 flange)  
t = 3 (ZV-N21-2 flange)  
53R  
53R  
41.3 0.2  
41.3 0.2  
54  
54  
10.6 0.3  
10.6 0.3  
36.6  
Two, 4.3 0.2 dia. holes  
36.6  
Two, 4.3 0.2 dia. holes  
12.7 dia. × 4.8  
*1  
PT  
12.7 dia. × 4.8  
*1  
PT  
26.1  
26.1  
JIS B0202  
G1/2 Effective  
thread: 4 threads min.  
JIS B0202 G1/2  
Effective  
thread: 4 threads min.  
(see note 2)  
(see note 3)  
5
17  
17  
5
OP  
OP  
31 0.2  
31 0.2  
23  
*2  
23  
*2  
3
3
75 0.2  
86  
75 0.2  
86  
5.5  
5.5  
Two, 5.4 +0.2dia.  
25.4 0.3  
Two, 5.4 +0.2dia.  
25.4 0.3  
0
0
holes  
holes  
*1. Stainless steel roller  
*2. Only the ZV2-N22-2 incorporate mounting holes.  
*1. Stainless steel roller  
*2. Only the ZV2-N21-2 incorporate mounting holes.  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
XV-QA277-2  
XV2-QA277-2  
ZV-N-2  
ZV2-N-2  
XV-N-2  
XV2-N-2  
ZV-N22-2  
ZV2-N22-2  
ZV-N21-2  
ZV2-N21-2  
ZV2-QA277-2  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
5.59 N  
1.67 N  
4 mm  
6 mm  
0.4 mm  
6.47 N  
1.67 N  
6 mm  
5.5 mm  
0.72 mm  
7.85 N  
2.35 N  
2 mm  
5 mm  
0.1 mm  
10.20 N  
2.35 N  
3 mm  
4 mm  
0.47 mm  
4.90 N  
0.98 N  
1 mm  
3.5 mm  
0.12 mm  
4.90 N  
0.98 N  
1 mm  
3.5 mm  
0.12 mm  
75.2 0.8 mm  
(see note 2)  
(ZV-N22-2)  
75.2 0.8 mm  
(see note 3)  
(ZV-N21-2)  
71.4 0.8 mm (see note 1)  
(ZV-N-2, XV-N-2)  
OP  
---  
Note: 1. OP for ZV2-N-2 and XV2-N-2 is 31.9 0.8 mm.  
2. OP for ZV2-N22-2 is 35.7 0.8 mm.  
3. OP for ZV2-N21-2 is 35.7 0.8 mm.  
7
ZE/ZV/ZV2/XE/XV/XV2  
Sealed Roller Arm Lever  
ZV(2)-NA2-2  
XV(2)-NA2-2  
One-way Action Sealed Roller Arm Lever  
ZV(2)-NA277-2  
XV(2)-NA277-2  
t=3 (ZV-NA277-2/XV-NA277-2 flanges)  
t=3 (ZV-NA2-2/XV-NA2-2 flanges)  
53R  
53R  
41.3 0.2  
54  
41.3 0.2 54  
Two, 4.3 0.2 dia. holes  
10.6 0.3  
8.7 dia. × 9  
*1  
10.6 0.3  
36.6  
39.7  
36.6  
39.7  
Two, 4.3 0.2 dia.  
Operates in this  
direction only  
*2  
19.1 dia. × 9  
*1  
(40)  
*2  
17.4R  
JIS B0202  
G1/2  
Effective  
thread: 4  
threads min.  
JIS B0202  
G1/2  
Effective  
thread: 4  
(23.1)  
PT  
PT  
threads min.  
19.3  
39.5 0.8  
5
17  
19.3  
39.5 0.8  
5
17  
79 0.8  
79 0.8  
31 0.2  
31 0.2  
23  
23  
3
3
*3  
75 0.2  
86  
Two, 5.4 +0.2dia.  
5.5  
*3  
0
75 0.2  
86  
25.4 0.3  
Two, 5.4 +0.2dia.  
5.5  
holes  
25.4 0.3  
0
holes  
*1. Stainless steel roller  
*2. Adjustment between 0° to 225°.  
*3. Only the ZV2-NA277-2 and XV2-NA277-2 incorporate  
mounting holes.  
*1. Stainless sintered alloy roller  
*2. Adjustment between 0° to 225°.  
*3. Only the ZV2-NA2-2 and XV2-NA2-2 incorporate mounting holes.  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
ZV-NA2-2  
ZV2-NA2-2  
XV-NA2-2  
XV2-NA2-2  
ZV-NA277-2  
ZV2-NA277-2  
XV-NA277-2  
XV2-NA277-2  
OF max.  
RF min.  
PT max.  
OT min.  
MD max.  
6.28 N  
2.26 N  
5 mm  
6 mm  
0.4 mm  
7.26 N  
2.26 N  
6 mm  
5.5 mm  
0.72 mm  
6.28 N  
2.26 N  
5 mm  
6 mm  
0.4 mm  
7.26 N  
2.26 N  
6 mm  
5.5 mm  
0.72 mm  
Safety Precautions  
Refer to Safety Precautions for All Limit Switches.  
Precautions for Correct Use  
Install Switches where they will not be directly subject to cutting  
chips, dust, or dirt. The Actuator and Switch must also be protected  
from the accumulation of cutting chips or sludge.  
Operating Environment  
Seal material may deteriorate if a Switch is used outdoor or where  
subject to special cutting oils, solvents, or chemicals. Always  
appraise performance under actual application conditions and set  
suitable maintenance and replacement periods.  
Not Suitable  
Suitable  
Be sure to protect part A with grease in order to maintain the  
mechanical durability and performance of the Limit Switch. The use  
of molybdenum disulfide grease is recommended.  
Constantly subjecting a Switch to vibration or shock can result in  
wear, which can lead to contact interference with contacts,  
operation failure, reduced durability, and other problems.  
Excessive vibration or shock can lead to false contact operation or  
damage. Install Switches in locations not subject to shock and  
vibration and in orientations that will not produce resonance.  
The Switches have physical contacts. Using them in environments  
containing silicon gas will result in the formation of silicon oxide  
(SiO2) due to arc energy. If silicon oxide accumulates on the  
contacts, contact interference can occur. If silicon oil, silicon filling  
agents, silicon cables, or other silicon products are present near the  
Switch, suppress arcing with contact protective circuits (surge  
killers) or remove the source of silicon gas.  
8
ZE/ZV/ZV2/XE/XV/XV2  
Mounting  
Mounting  
With the Roller Lever-type Enclosed Switches, the roller arm has  
been temporarily tightened prior to shipment, so that its position  
may be adjusted later. When mounting the Switch, be sure to re-  
tighten the roller arm so as to prevent it from becoming loose during  
operation.  
Mounting Holes  
Side Mounting  
Bottom Mounting  
Two, 4.3 dia.  
mounting holes or  
M4 screw holes  
Two, 4.3 dia.  
mounting holes or  
M4 screw holes  
To adequately maintain the seals at the mounting screw section on  
the side of the Enclosed Switch, insert each O-ring correctly and  
secure it with the lock nut.  
To provide the Switch with improved sealing property, use of the SC  
Connector is recommended. Refer to Limit Switch Connectors for  
details on SC Connectors.  
25.4 0.1  
41.3 0.15  
Side Diagonal Mounting  
Two, 5.4 dia.  
mounting holes or  
M5 screw holes  
When routing wires into the conduit opening, be sure that cuttings  
and other foreign matter do not enter the Switch.  
31 0.1  
Appropriate Tightening Torque  
75 0.1  
A loose screw may result in a malfunction. Be sure to tighten each  
screw to the proper tightening torque as shown below.  
Operation  
No.  
1
Type  
Appropriate tightening torque  
1.18 to 1.37 N·m  
Operating method, shape of cam or dog, operating frequency, and  
the overtravel (OT) have significant effect on the service life and  
precision of the Limit Switch. Make sure that the shape of the cam  
is smooth enough.  
Check that OT has a sufficient margin. The actual OT should be  
rated OT x 0.7 to 1.  
Cover mounting screw  
Switch mounting screw*1  
Switch mounting screw*2  
2
1.18 to 1.37 N·m  
3
4.90 to 5.88 N·m  
Switch terminal screw  
(M4 screws)  
4
5
0.78 to 1.18 N·m  
4.90 to 5.88 N·m  
Roller arm mounting nut  
*1. This torque range applies to side mounting or bottom mounting. (M4 screws)  
*2. This torque range applies to diagonal side mounting. (M5 Allen-head bolt)  
Dedicated Wrench  
1. The roller arm can be set freely within a range of 225° after  
loosening the nut.  
2. The roller arm mounting bracket can be set in any direction after  
loosening the nut.  
Make sure that the nut is free of foreign substances when the nut is  
loosened.  
A dedicated wrench is provided separately.  
Model  
SUPANA FOR ZE  
9
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  
Mouser Electronics  
Authorized Distributor  
Click to View Pricing, Inventory, Delivery & Lifecycle Information:  
Omron:  
ZV-N-2S ZE-NJ-2S ZE-QCL-2S ZE-N22-2S ZE-N-2S ZE-Q22-2S ZE-NA2-2S XE-NA277-2 ZE-N-2 ZE-N21-2S  
ZE-N22-2 ZE-N-2G ZE-NA2-2 ZE-NA2-2G ZE-NA2-2S-NL ZE-NA277-2G ZE-NA277-2S ZE-NCL-2S ZE-Q-2 ZE-  
Q21-2 ZE-Q21-2G ZE-Q21-2S ZE-Q22-2 ZE-Q22-2G ZE-Q-2G ZE-Q-2S ZE-QA2-2 ZE-QA2-2S ZE-QA277-2  
ZE-QA277-2S ZE-YN-2 ZE-YQ-22-2 ZV2-N-2 ZV2-N21-2 ZV2-N21-2S ZV2-N22-2 ZV2-N22-2S ZV2-N-2S ZV2-  
NA2-2S ZV2-NA277-2S ZV2-NJ-2S ZV2-Q-2S ZV2-QA2-2S ZV-N22-2S ZV-NA2-2 ZV-NA2-2S ZV-NA277-2S ZV-  
NCL-2S ZV-NJ-2S ZV-Q21-2S ZV-Q22-2S ZV-QA2-2S ZV-N21-2  

相关型号:

ZE-Q-2ZEQ21-2

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON

ZE-Q21-2

Long Service Life and Large Breaking Power
OMRON

ZE-Q21-2G

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON

ZE-Q21-2S

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON

ZE-Q22-2

Long Service Life and Large Breaking Power
OMRON

ZE-Q22-2G

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON

ZE-Q22-2S

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON

ZE-QA2-2

Long Service Life and Large Breaking Power
OMRON

ZE-QA2-2S

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON

ZE-QA277-2

Long Service Life and Large Breaking Power
OMRON

ZE-QA277-2S

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON

ZE-QCL-2S

General-purpose Enclosed Switches with High Breaking Capacity and High Durability
OMRON