Product Description  
Oplink’s Single Channel Bi-directional Integrated Tap Monitor (BTMS) is a hybrid component  
that integrates a flat spectral response of a thin-film tap with a high sensitivity PIN photodiode  
for power monitoring applications.The Bi-directional feature allows power monitoring from  
both input and output ports. BTMS minimizes component assembly costs and module foot-  
print while increasing module design efficiency by facilitating fiber management.  
The BTMS integrates the functionality of an optical coupler and a photodiode while delivering  
low insertion loss and low dark current with high temperature stability over a wide wavelength  
range. It is compact and easy to mount on a PCB board for module and network system use.  
Applications include DWDM channel power monitoring,optical network switching/protection  
monitoring, re-configurable optical add/drop multiplexers systems.  
Oplink can provide customized designs to meet specialized feature applications. Also, Oplink  
offers modular assemblies that integrate other components to form a full function module or  
subsystem.  
Functional Diagram  
Input  
Output  
PD  
Performance Specificationns  
Parameters  
Features  
Specification  
Unit  
2-/3-pin Package Easily Mounted  
Operating Wavelength Range  
1260~1360 1510~1610  
mm  
on a PCB  
2%  
5%  
10%  
≤ 0.4  
≤ 0.6  
≤ 0.9  
Flat and Broad Operating  
Insertion Loss (@ λOp, TOp, All SOP, exclude  
connector)  
dB  
Wavelength Range  
Through  
Low Insertion Loss and PDL  
Low Dark Current  
Polarization Dependent Loss  
≤ 0.1  
≥ 45  
dB  
dB  
Return loss (exclude connector)  
Various Tap Ratios Available  
2%  
5%  
10%  
10~23  
26~59  
52~110  
14~25  
35~65  
70~120  
Responsivity (relative to nominal power at  
input port)  
mA/W  
High Temperature Stability with  
Tapped  
Hermetically Sealed Photodiode  
Monitoring  
Responsivity Polarization Dependence  
≤ 0.1  
≤ 0.5  
≤ 10  
≥ 0.5  
≤ 20  
≤ 5  
dB  
dB  
Monitor Optical Signal from One  
[1]  
Uniformity  
Both Input and Output  
PD Dark Current (@ 70°C, -5V bias)  
nA  
GHz  
V
Bandwidth (50 ohm, 5V, -3dB)  
PD  
Reverse Voltage  
Applications  
Forward Current  
mA  
EDFAs and Raman amplifiers  
2%  
5%  
10%  
≤ 21  
≤ 16  
≤ 12  
Add/Drop and optical protection  
Input Optical Power  
Conditions  
dBm  
monitoring  
DWDM/CWDM systems  
Operating Temperature Range (<85%RH,Non-condensing)  
Storage Temperature Range (<85%RH, Non-condensing)  
0 to +70  
-40 to +85  
SMF-28  
°C  
°C  
Fiber Type  
Notes: 1) Excluding connectors.  
R03.20080714  
Bi-directional Single Channel Integrated Tap Monitors  
BTMS Series  
Mechanical Drawing / Package Dimensions (dimension in mm)  
Standard Package (P1, Bare Fiber or LooseTube)  
Miniature Package (P2, Bare Fiber)  
Input(Black)  
Note:  
Anode is connected to the metal housing.  
Standard Package Pin Assignment  
Pin 1: Anode  
Pin 2: Cathode  
Pin 3: Case Ground  
Miniature Package (P3, LooseTube)  
Input(Blue)  
Output(White)  
Note:  
Anode is connected to the metal housing.  
Ordering Information  
Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink’s OEM  
design team or account manager for your requirements and ordering information (510) 933-7200.  
0
5
0
0
BTMS  
Bandwidth  
0.5G= 05  
Tap Ratio  
2/98 = 02  
5/95 = 05  
10/90 = 10  
Connector  
Type  
Fiber Length  
0.5meter= H  
1.0meter= 1  
1.5meter= 5  
2.0meter= 2  
None = 1  
FC/PC=2  
FC/SPC=3  
FC/APC=4  
SC/PC=5  
SC/SPC=6  
SC/APC=7  
ST=8  
Wavelength  
1310/1550nm= D  
1310nm= 3  
C+L band= E  
Package & Fiber Type  
P1+250µm bare fiber =11  
P1+900µm loose tube =12  
P2+250µm bare fiber = 21  
P3+900µm loose tube = 32  
LC=9  
MU=A  
RoHS:  
1. Add “Gto the end of the above PN for RoHS 6 Requirement.  
R03.20080714  
Monitoring/Conditioning Amplification Transmission Interconnect RGB Laser Modules  
Product Lines: Mux/Demux  
Switching/Routing  
Coupling/Splitting  

BTMS302050021H 相关器件

型号 制造商 描述 价格 文档
BTMS3020500321 OPLINK Bi-directional Single Channel Integrated Tap Monitors 获取价格
BTMS3020500322 OPLINK Bi-directional Single Channel Integrated Tap Monitors 获取价格
BTMS3020500325 OPLINK Bi-directional Single Channel Integrated Tap Monitors 获取价格
BTMS302050032H OPLINK Bi-directional Single Channel Integrated Tap Monitors 获取价格
BTMS302050051 OPLINK Bi-directional Single ChannelTap Monitors 获取价格
BTMS3020500H1 OPLINK Bi-directional Single ChannelTap Monitors 获取价格
BTMS305050011 OPLINK Bi-directional Single ChannelTap Monitors 获取价格
BTMS3050500111 OPLINK Bi-directional Single Channel Integrated Tap Monitors 获取价格
BTMS30505001111 OPLINK Bi-directional Single ChannelTap Monitors 获取价格
BTMS3050500112 OPLINK Bi-directional Single Channel Integrated Tap Monitors 获取价格

BTMS302050021H 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6