Multi-rate 10-Gigabit DWDM 40km XFP
Transceiver with Digital Diagnostics
TXD3XGGI2xx
Pb
Product Description
TheTXD3XGGI2xx DWDM XFP multi-rate fiber optic transceivers with digital
diagnostics monitoring functionality provide a quick and reliable interface
for 40km 10Gbps DWDM applications. The diagnostic functions, alarm and
warning features as described in the XFP Multi-Source Agreement (MSA)
are provided via standard I2C serial interface. The transceivers are compliant
with the XFP Multi-Source Agreement and are designed to support SONET/
SDH, 10G Ethernet, and 10G Fiber Channel data rates from 9.95Gb/s to
11.09Gb/s.
Each transceiver utilizes an electro-absorption modulator integrated laser
with an operating wavelength in full compliance with 100GHz (0.8nm)
spacing per the ITU-grid. The transceivers satisfy Class I Laser Safety
requirements in accordance with the U.S. FDA/CDRH and international IEC-
60825 standards.
Features
The transceivers connect to standard 30-pad XFP connectors for hot plug
capability. This allows the system designer to make configuration changes
or maintenance by simply plugging in different types of transceivers
without removing the power supply from the host system.
Lead Free Design & Fully RoHS Compliant
Compliant with XFP MSA
Compliant with OC-192/STM-64
Compliant with ITU-T G.709
The transmitter and receiver DATA interfaces are AC coupled Current Mode
Logic (CML). LV-TTL Transmitter Disable control input and Loss of Signal
output interfaces are also provided.
Support DWDM 10G Ethernet Applications
Support 10G Fiber Channel Applications
Digital Diagnostics Monitoring
Temperature-stabilized EML Transmitter
Low Power Consumption
The transceivers operate from +3.3V and +5.0V power supplies over a
operating case temperature range of -5°C to +70°C (Commercial), -5°C to
+85°C (Extended), or -40°C to +85°C (Industrial).
Wide Case Operating Temperature Range
Transmission Distance up to 40km
Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
TST
Storage Temperature
- 40
+ 85
°C
Commercial
Extended
Industrial
- 5
- 5
+ 70
+ 85
+ 85
+ 3.6
+ 6.0
85
Operating Case Temperature 1
TOP
°C
- 40
- 0.2
- 0.2
0
VCC
VCC
3
5
Supply Voltage
V
Operating Relative Humidity 2
%
V
RH
VIN
V CC
Input Voltage
1
0
Case temperature is measured on top side of XFP module.
Non condensing
2
S0330. Rev.04. (web) 2013-01-09
TXD3XGGI2xx
(Over Operating Case Temperature Range)
Transmitter Performance Characteristics
Parameter
Operating Data Rate
Symbol
Minimum
Typical
Maximum
Units
B
PO
9.95
- 1.0
-
-
-
-
-
11.09
+ 3.0
- 45.0
-
Gb/s
dBm
dBm
dB
Average Optical Output Power (50% duty cycle)
Transmitter OFF Power
POFF
ER
Extinction Ratio @ 9.95Gb/s to 10.7Gb/s
Center Wavelength 1
8.2
λC
See Ordering Information Table
nm
Spectral Width (-20dB) 2
Δλ20
SMSR
RIN
refT
-
30
-
-
-
-
-
-
-
-
-
1.0
-
nm
Side Mode Suppression Ratio
Relative Intensity Noise
dB
- 130
- 27
0.3
0.1
2.0
2.5
dB/Hz
dB
Reflectance Tolerance
-
20 kHz – 80 MHz
JG20K
JG4M
-
UIpp
UIpp
3
Jitter Generation
4 MHz – 80 MHz
@ 9.95Gb/s (10-12 BER)
@ 11.09Gb/s (10-4 BER)
-
-
4
Dispersion Penalty
DP
dB
-
Optical Output Eye
Compliant with GR253-CORE, IEEE 803.3ae , and ITU-T G.959
1 BOL: +/-0.05nm from ITU grid. EOL: +/-0.1nm from ITU grid.
2 Measured with OSA and 0.1nm resolution bandwidth.
3 Jiꢀer generation is compliant with GR-253 and G.8251.
(Over Operating Case Temperature Range)
Receiver Performance Characteristics
Parameter
Operating Data Rate
Symbol
Minimum
Typical
Maximum
Units
9.95
-
11.09
B
Gb/s
nm
Wavelength of Operation
λ
1260
-
-
-
-
-
-
-
-
1570
- 16.0
- 19.0
-
@ 9.95Gb/s (10-12 BER)
Receiver Sensitivity
-
Pmin
dBm
dBm
dBm
@ 11.09Gb/s (10-4 BER)
-
+ 0.5
-
Maximum Input Power
PMAX
Plos+
Plos-
-
Increasing Light Input
LOS Thresholds
- 16.0
-
Decreasing Light Input
- 28.0
0.5
-
LOS Hysteresis
-
dB
dB
Receiver Reflectance
-
- 27
Laser Safety: All transceivers are Class I Laser
Oplink Communications, Inc.
products per FDA/CDRH and IEC-60825 standards.
They must be operated under specified operating
conditions.
This product complies with
21 CFR 1040.10 and 1040.11
Meets Class I Laser Safety Requirements
Oplink Communications, Inc
S0330. Rev.04. (web) 2013-01-09
2
TXD3XGGI2xx
Electrical Interface (Over Operating Case Temperature Range)
Parameter
Differential Impedance
Symbol
Minimum
Typical
Maximum
Units
Zd
-
100
-
Ω
Vpp, diff_in
Vpp, diff_out
Differential Input Voltage Swing
Differential Output Voltage Swing
Output Rise/Fall Time (20 to 80%)
120
-
820
mV
mV
ps
340
550
850
T /Tf
24
-
-
-
-
-
-
0.8
r
VIL
VIH
VOL
VOH
- 0.3
TX_Dis, P_Down/RST
V
V
2.0
VCC + 0.3
0.4
0
XFP Interrupt, Mod_NR, RX_LOS
host_VCC - 0.5
host_VCC + 0.3
(Over Operating Case Temperature Range)
Electrical Power Supply Characteristics
Parameter
Power Supply Voltage
Symbol
Minimum
Typical
Maximum
Units
VCC3
VCC5
ICC3
3.13
3.3
3.47
5.25
750
500
3.5
V
4.75
5.0
-
-
-
-
-
-
-
-
Supply Current
mA
ICC5
Power Dissipation
PW
W
W
PDW
1.5
P_Down Power Dissipation
XFP Transceiver Electrical Pad Layout
Host Board Connector Pad Layout
GND
30 GND
29 TD+
28 TD-
1
GND
TD+
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
1
GND
V
5
2
EE
2
V
5
EE
Mod_DeSel
Interrupt
TX_Dis
3
TD-
3
Mod_DeSel
Interrupt
TX_Dis
27
26
25
24
23
22
21
20
19
18
17
16
GND
4
GND
4
GND
5
GND
5
V
5
RefCLK-
RefCLK+
GND
6
CC
RefCLK-
RefCLK+
6
V
5
cc
GND
7
7
GND
V
3
8
CC
GND
Toward
Bezel
Toward
ASIC
8
V
V
3
3
cc
V
3
V
2
9
CC
CC
V
2
cc
9
cc
SCL
TP_Down/RS
10
11
12
13
14
15
P_Down/RST
10
11
12
13
14
15
SCL
SDA
V
2
CC
V
2
cc
SDA
Mod_Abs
Mod_NR
RX_LOS
GND
GND
RD+
RD-
GND
RD+
RD-
Mod_Abs
Mod_NR
RX_LOS
GND
GND
GND
Bottom of XFP Board
(as viewed thru top of board)
Top of XFP Board
Oplink Communications, Inc
S0330. Rev.04. (web) 2013-01-09
3
TXD3XGGI2xx
Module Pin Description
Pin
Logic
Symbol
Description
1
Module Ground
-
GND
VEE5
2
3
4
-
Optional -5.2V Power Supply (Not Required)
LVTTL-I
Mod_DeSel
Module De-select; When held low allows module to respond to 2-wire serial interface
Interrupt; Indicates presence of an important condition which can be read over the 2-wire serial
Interface
LVTTL-O
Interrupt
5
LVTTL-I
TX_Dis
VCC5
Transmitter Disable; Turns off transmitter laser output
+5V Power Supply
6
-
7
-
GND
VCC3
Module Ground
8
-
+3.3V Power Supply
9
-
LVTTL-I/O
LVTTL-I/O
LVTTL-O
LVTTL-O
LVTTL-O
-
VCC3
+3.3V Power Supply
10
11
12
13
14
15
16
17
18
19
20
SCL
2-Wire Serial Interface Clock
2-Wire Serial Interface Data Line
Indicates Module is not present. Grounded in the Module
Module Not Ready; Indicating Module Operational Fault
Receiver Loss Of Signal Indicator
Module Ground
SDA
Mod_Abs
Mod_NR
RX_LOS
GND
GND
RD-
-
Module Ground
CML-O
CML-O
-
Receiver Inverted Data Output
Receiver Non-Inverted Data Output
Module Ground
RD+
GND
VCC2
-
Nor Used
Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire
serial interface must be functional in the low power mode.
21
LVTTL-I
P_Down/RST
Reset; The falling edge initiates a complete reset of the module including the 2-wire serial interface,
equivalent to a power cycle.
22
23
24
25
26
27
28
29
30
-
VCC2
GND
Not Used
-
PECL-I
PECL-I
-
Module Ground
RefCLK+
RefCLK-
GND
Reference Clock Non-Inverted Input (Not Required)
Reference Clock Inverted Input (Not Required)
Module Ground
-
GND
Module Ground
CML-I
CML-I
-
TD-
Transmitter Inverted Data Input
Transmitter Non-Inverted Data Input
Module Ground
TD+
GND
S0330. Rev.04. (web) 2013-01-09
4
Oplink Communications, Inc
TXD3XGGI2xx
Host Board Termination & Coupling
50Ω line
TD+
CML
INPUTS
50Ω line
50Ω line
TD-
RD+
CML
OUTPUTS
1µH coil or
ferrite inductor
50Ω line
RD-
8, 9
+3.3V
+5.0V
+
0.1
10
0.1
0.1
ASIC/
SerDes
XFP
1µH coil or
+3.3V
ferrite inductor
+3.3V
6
+
0.1
10
R
+3.3V
R
SCL, SDA,
R
Mod_Abs, Mod_NR,
Interrupt, RX_LOS
R: 4.7 to 10kΩ
All caps are in units of µF
Application Notes
Electrical Interface: All signal interfaces are compliant with
the XFP MSA specification. The high speed DATA interface is
differential AC-coupled internally and can be directly connected
to a 3.3V SERDES IC.
be added to the Mod_NR. The Mod_NR output pin is an open
collector and must be pulled to Host_Vcc on the host board.
P_Down/RST: The negative edge of Reset Function signal
initiates a complete module reset.
RX_LOS: The Loss of Signal circuit monitors the level of the
incoming optical signal and generates a logic HIGH when an
insufficient photocurrent is produced.
Module Behavior During P_Down and RST: During execution
of a reset (t_init) or while held in Power Down mode, a module
may be unable to determine the correct value for Mod_NR and
RX_LOS. These outputs as well as all interrupt related flags,
except completion of Reset flag, shall be disregarded by the
host. When the module completes a Reset and is not in Power
Down mode, the module must represent the correct value of
both signals on its outputs before posting a completion of reset
interrupt to the host.
TX_Dis: When theTX Disable pin is at logic HIGH, the transmitter
optical output is disabled. (less than -45dBm).
P_Down: The Power Down Function pin, when held High by
the host, places the module in the standby (Low Power) mode
with a maximum power dissipation of 1.5W. This protects hosts
which are not capable of cooling higher power modules which
may be accidentally inserted.The module’s 2-wire serial interface
and all laser safety functions must be fully functional in this low
power mode. During P_Down, the module shall still support the
completion of reset Interrupt, as well as maintain functionality
of the variable power supply.
At no time shall a module cause spurious assertion of the
Interrupt pin. When a host initially applies power to a module
with the P_Down/RST signal asserted, a module comes up in
power down mode. The module shall only assert the Interrupt
signal pin to inform the host it has completed a reset. The
completion of reset flag shall be the only interrupt source flag
set during power down mode. The host is expected to clear this
interrupt before releasing the module from the power down
mode. The transition from power down mode to normal mode
will trigger a reset of the module and result in a 2nd module reset
and a 2nd reset completion interrupt to the host.
Mod_NR:The Mod_NR is an output pin that when High, indicates
that the module has detected a condition that renders transmitter
and or receiver data invalid, shall consist of logical OR of the
following signals:
• Transmit Signal Conditioner Loss of Lock
• Transmitter Laser Fault
Power Supply and Grounding: The power supply line should
be well-filtered. All 0.1μF power supply bypass capacitors should
be as close to the transceiver module as possible.
• Receiver Signal Conditioner Loss of Lock
Other conditions deemed valuable to the detection of fault may
Oplink Communications, Inc
S0330. Rev.04. (web) 2013-01-09
5
TXD3XGGI2xx
Package Outline
DIMENSION IN MILLIMETERS
NOTES: UNLESS OTHERWISE
SPECIFIED
Ordering Information
Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink’s Sales and Mar-
keting for your requirements and ordering information (510) 933-7200 or Sales@oplink.com.
Center
Wavelength
(nm)
ITU
Frequency
(THz)
Wavelength
Reference
Latch
Color
Model Name
Operating Temperature
Distance
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
TXD3XGGI2C00061G
TXD3XGGI2C00060G
TXD3XGGI2C00059G
TXD3XGGI2C00058G
TXD3XGGI2C00057G
TXD3XGGI2C00056G
TXD3XGGI2C00055G
TXD3XGGI2C00054G
TXD3XGGI2C00053G
TXD3XGGI2C00052G
TXD3XGGI2C00051G
TXD3XGGI2C00050G
TXD3XGGI2C00049G
TXD3XGGI2C00048G
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
1528.77
1529.55
1530.33
1531.12
1531.90
1532.68
1533.47
1534.25
1535.04
1535.82
1536.61
1537.40
1538.19
1538.98
196.1
196
61
60
59
58
57
56
55
54
53
52
51
50
49
48
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
195.9
195.8
195.7
195.6
195.5
195.4
195.3
195.2
195.1
195.0
194.9
194.8
Oplink Communications, Inc
S0330. Rev.04. (web) 2013-01-09
6
TXD3XGGI2xx
Center
Wavelength
(nm)
ITU
Frequency
(THz)
Wavelength
Reference
Latch
Model Name
Operating Temperature
Distance
Color
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
TXD3XGGI2C00047G
TXD3XGGI2C00046G
TXD3XGGI2C00045G
TXD3XGGI2C00044G
TXD3XGGI2C00043G
TXD3XGGI2C00042G
TXD3XGGI2C00041G
TXD3XGGI2C00040G
TXD3XGGI2C00039G
TXD3XGGI2C00038G
TXD3XGGI2C00037G
TXD3XGGI2C00036G
TXD3XGGI2C00035G
TXD3XGGI2C00034G
TXD3XGGI2C00033G
TXD3XGGI2C00032G
TXD3XGGI2C00031G
TXD3XGGI2C00030G
TXD3XGGI2C00029G
TXD3XGGI2C00028G
TXD3XGGI2C00027G
TXD3XGGI2C00026G
TXD3XGGI2C00025G
TXD3XGGI2C00024G
TXD3XGGI2C00023G
TXD3XGGI2C00022G
TXD3XGGI2C00021G
TXD3XGGI2C00020G
TXD3XGGI2C00019G
TXD3XGGI2C00018G
TXD3XGGI2C00017G
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
- 5°C to +70°C
1539.77
1540.56
1541.35
1542.14
1542.94
1543.73
1544.53
1545.32
1546.12
1546.92
1547.72
1548.51
1549.32
1550.12
1550.92
1551.72
1552.52
1553.33
1554.13
1554.94
1555.75
1556.55
1557.36
1558.17
1558.98
1559.79
1560.61
1561.42
1562.23
1563.05
1563.86
194.7
194.6
194.5
194.4
194.3
194.2
194.1
194.0
193.9
193.8
193.7
193.6
193.5
193.4
193.3
193.2
193.1
193.0
192.9
192.8
192.7
192.6
192.5
192.4
192.3
192.2
192.1
192.0
191.9
191.8
191.7
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
Center
Wavelength
(nm)
ITU
Frequency
(THz)
Wavelength
Reference
Latch
Color
Model Name
Operating Temperature
Distance
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
TXD3XGGI2E00061G
TXD3XGGI2E00060G
TXD3XGGI2E00059G
TXD3XGGI2E00058G
TXD3XGGI2E00057G
TXD3XGGI2E00056G
TXD3XGGI2E00055G
TXD3XGGI2E00054G
TXD3XGGI2E00053G
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
1528.77
1529.55
1530.33
1531.12
1531.90
1532.68
1533.47
1534.25
1535.04
196.1
196
61
60
59
58
57
56
55
54
53
Red
Red
Red
Red
Red
Red
Red
Red
Red
40km
40km
40km
40km
40km
40km
40km
40km
40km
195.9
195.8
195.7
195.6
195.5
195.4
195.3
Oplink Communications, Inc
S0330. Rev.04. (web) 2013-01-09
7
TXD3XGGI2xx
Center
Wavelength
(nm)
ITU
Frequency
(THz)
Wavelength
Reference
Latch
Model Name
Operating Temperature
Distance
Color
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
Extended
TXD3XGGI2E00052G
TXD3XGGI2E00051G
TXD3XGGI2E00050G
TXD3XGGI2E00049G
TXD3XGGI2E00048G
TXD3XGGI2E00047G
TXD3XGGI2E00046G
TXD3XGGI2E00045G
TXD3XGGI2E00044G
TXD3XGGI2E00043G
TXD3XGGI2E00042G
TXD3XGGI2E00041G
TXD3XGGI2E00040G
TXD3XGGI2E00039G
TXD3XGGI2E00038G
TXD3XGGI2E00037G
TXD3XGGI2E00036G
TXD3XGGI2E00035G
TXD3XGGI2E00034G
TXD3XGGI2E00033G
TXD3XGGI2E00032G
TXD3XGGI2E00031G
TXD3XGGI2E00030G
TXD3XGGI2E00029G
TXD3XGGI2E00028G
TXD3XGGI2E00027G
TXD3XGGI2E00026G
TXD3XGGI2E00025G
TXD3XGGI2E00024G
TXD3XGGI2E00023G
TXD3XGGI2E00022G
TXD3XGGI2E00021G
TXD3XGGI2E00020G
TXD3XGGI2E00019G
TXD3XGGI2E00018G
TXD3XGGI2E00017G
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
- 5°C to +85°C
1535.82
1536.61
1537.40
1538.19
1538.98
1539.77
1540.56
1541.35
1542.14
1542.94
1543.73
1544.53
1545.32
1546.12
1546.92
1547.72
1548.51
1549.32
1550.12
1550.92
1551.72
1552.52
1553.33
1554.13
1554.94
1555.75
1556.55
1557.36
1558.17
1558.98
1559.79
1560.61
1561.42
1562.23
1563.05
1563.86
195.2
195.1
195.0
194.9
194.8
194.7
194.6
194.5
194.4
194.3
194.2
194.1
194.0
193.9
193.8
193.7
193.6
193.5
193.4
193.3
193.2
193.1
193.0
192.9
192.8
192.7
192.6
192.5
192.4
192.3
192.2
192.1
192.0
191.9
191.8
191.7
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
Center
Wavelength
(nm)
ITU
Frequency
(THz)
Wavelength
Reference
Latch
Color
Model Name
Operating Temperature
Distance
Industrial
Industrial
Industrial
Industrial
TXD3XGGI2I00061G
TXD3XGGI2I00060G
TXD3XGGI2I00059G
TXD3XGGI2I00058G
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
1528.77
1529.55
1530.33
1531.12
196.1
196
61
60
59
58
Red
Red
Red
Red
40km
40km
40km
40km
195.9
195.8
Oplink Communications, Inc
S0330. Rev.04. (web) 2013-01-09
8
TXD3XGGI2xx
Center
Wavelength
(nm)
ITU
Frequency
(THz)
Wavelength
Reference
Latch
Color
Model Name
Operating Temperature
Distance
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
Industrial
TXD3XGGI2I00057G
TXD3XGGI2I00056G
TXD3XGGI2I00055G
TXD3XGGI2I00054G
TXD3XGGI2I00053G
TXD3XGGI2I00052G
TXD3XGGI2I00051G
TXD3XGGI2I00050G
TXD3XGGI2I00049G
TXD3XGGI2I00048G
TXD3XGGI2I00047G
TXD3XGGI2I00046G
TXD3XGGI2I00045G
TXD3XGGI2I00044G
TXD3XGGI2I00043G
TXD3XGGI2I00042G
TXD3XGGI2I00041G
TXD3XGGI2I00040G
TXD3XGGI2I00039G
TXD3XGGI2I00038G
TXD3XGGI2I00037G
TXD3XGGI2I00036G
TXD3XGGI2I00035G
TXD3XGGI2I00034G
TXD3XGGI2I00033G
TXD3XGGI2I00032G
TXD3XGGI2I00031G
TXD3XGGI2I00030G
TXD3XGGI2I00029G
TXD3XGGI2I00028G
TXD3XGGI2I00027G
TXD3XGGI2I00026G
TXD3XGGI2I00025G
TXD3XGGI2I00024G
TXD3XGGI2I00023G
TXD3XGGI2I00022G
TXD3XGGI2I00021G
TXD3XGGI2I00020G
TXD3XGGI2I00019G
TXD3XGGI2I00018G
TXD3XGGI2I00017G
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
- 40°C to +85°C
1531.90
1532.68
1533.47
1534.25
1535.04
1535.82
1536.61
1537.40
1538.19
1538.98
1539.77
1540.56
1541.35
1542.14
1542.94
1543.73
1544.53
1545.32
1546.12
1546.92
1547.72
1548.51
1549.32
1550.12
1550.92
1551.72
1552.52
1553.33
1554.13
1554.94
1555.75
1556.55
1557.36
1558.17
1558.98
1559.79
1560.61
1561.42
1562.23
1563.05
1563.86
195.7
195.6
195.5
195.4
195.3
195.2
195.1
195.0
194.9
194.8
194.7
194.6
194.5
194.4
194.3
194.2
194.1
194.0
193.9
193.8
193.7
193.6
193.5
193.4
193.3
193.2
193.1
193.0
192.9
192.8
192.7
192.6
192.5
192.4
192.3
192.2
192.1
192.0
191.9
191.8
191.7
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
40km
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Commu-
nications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements
of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc.
© 2013, Oplink Communications, Inc.
S0330. Rev.04. (web) 2013-01-09
9