XPS-2360WG_09 [OPTOWAY]

10Gbps / 60km / 1550 nm XFP Single-Mode Optical Transceiver for 10GbE / 10G FC; 万兆/ 60公里/ 1550 nm的XFP单模光纤收发器,用于万兆/ 10G FC
XPS-2360WG_09
型号: XPS-2360WG_09
厂家: OPTOWAY TECHNOLOGY INC    OPTOWAY TECHNOLOGY INC
描述:

10Gbps / 60km / 1550 nm XFP Single-Mode Optical Transceiver for 10GbE / 10G FC
万兆/ 60公里/ 1550 nm的XFP单模光纤收发器,用于万兆/ 10G FC

光纤
文件: 总9页 (文件大小:242K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
XPS-2360WG / XPS-2360BWG / XPS-2360AWG  
(RoHS Compliant)  
10Gbps / 60km / 1550 nm XFP Single-Mode Optical Transceiver for 10GbE / 10G FC  
**********************************************************************************************************************************************************************  
FEATURES  
DESCRIPTION  
l Support 9.95 Gbps to 10.5 Gbps  
l Complaint with XFP MSA  
XPS-2360WG series transceiver is designed for  
single-mode fibre serial optical data communications such as  
10G Ethernet 10GBASE-ER/EW and 10G Fibre Channel.  
The transceiver consists of two sections: The transmitter  
section consists of a temperature-stabilized 1550 nm  
electrical-modulated laser (EML), driver and signal  
conditioner. The receiver section incorporates a PIN  
photodiode integrated with a trans-impedance preamplifier  
(TIA) and signal conditioner.  
l Compliant with XFI 10G Serial Electrical Interface  
l Maximum Link Length of 60 km  
l Temperature-stabilized 1550 nm EML Transmitter  
l 2-Wire Interface for Integrated Digital Diagnostic  
Monitoring  
l XFI Loopback Mode  
l No reference Clock required  
l Power Dissipation < 3.5 W  
The module is with the XFP 30-pin connector to allow  
hot plug capability. Integrated Tx and Rx signal conditioners  
provide high jitter-tolerance for full XFI compliance and no  
external reference clock required. The internally ac coupled  
high speed serial I/O simplifies interfacing to external  
circuitry. Dual 5V and 3.3V power supplies are needed. The  
optical output can be disabled by LVTTL logic high-level  
input of TX_DIS. Loss of signal (RX_LOS) output is  
provided to indicate the loss of an input optical signal of  
receiver.  
l Dual 5V and +3.3 V Power Supply  
l RoHS-6 Compliant  
l -5 to 70oC Operating: XPS-2360WG  
l -5 to 85oC Operating: XPS-2360BWG  
l -40 to 85oC Operating: XPS-2360AWG  
APPLICATIONS  
l 10GBASE-ER/EW  
l 60 km 10G Fibre Channel  
A serial EEPROM in the transceiver allows the user to  
access transceiver digital diagnostic monitoring and  
configuration data via the 2-wire XFP Management  
Interface. This interface uses a single address, A0h, with a  
memory map divided into a lower and upper area. Basic  
digital diagnostic data is held in the lower area while specific  
data is held in a series of tables in the high memory area.  
LASER SAFETY  
This single-mode transceiver is a Class 1 laser product. It  
complies with IEC-60825 and FDA 21 CFR 1040.10 and  
1040.11. The transceiver must be operated within the  
specified temperature and voltage limits. The optical ports  
of the module shall be terminated with an optical connector  
or with a dust plug.  
ORDER INFORMATION  
P/No.  
Bit Rate  
(Gb/s)  
10GBASE Distance  
(km)  
Wavelength  
(nm)  
Package  
Case Temp  
(oC)  
RoHS  
Compliant  
Yes  
XPS-2360WG  
XPS-2360BWG  
XPS-2360AWG  
9.95 10.5  
9.95 10.5  
9.95 10.5  
ER/EW  
ER/EW  
ER/EW  
60  
60  
60  
1550 EML  
1550 EML  
1550 EML  
XFP with DMI  
XFP with DMI  
XFP with DMI  
-5 to 70  
-5 to 85  
-40 to 85  
Yes  
Yes  
Absolute Maximum Ratings  
Parameter  
Symbol  
Min  
Max  
85  
Units  
Notes  
Storage Temperature  
Tstg  
Topr  
-40  
-5  
oC  
oC  
Operating Case Temperature  
70  
XPS-2360WG  
-5  
85  
XPS-2360BWG  
XPS-2360AWG  
Non condensing  
-40  
0
85  
Relative Humidity  
RH  
85  
%
V
Power Supply Voltage (5V)  
Power Supply Voltage (3.3V)  
Receiver Input Optical Power  
Vcc5  
-0.5  
-0.5  
6.0  
3.6  
4
VCC3  
V
Mip  
dBm  
Received average power  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
2
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
Recommended Operating Conditions  
Parameter  
Symbol  
Min  
4.75  
3.13  
Typ  
5
Max  
5.25  
3.47  
500  
750  
3.5  
Units / Notes  
VCC  
5
3
Power Supply Voltage (5V)  
Power Supply Voltage (3.3V)  
Power Supply Current (@5V)  
Power Supply Current (@3.3V)  
Power Dissipation  
V
VCC  
3.3  
V
mA / 1  
ICC5  
ICC3  
mA / 1  
PD  
Topr  
W
Operating Case Temperature  
-5  
-5  
70  
oC / XPS-2360WG  
oC / XPS-2360BWG  
oC / XPS-2360AWG  
Gb/s  
85  
-40  
9.95  
85  
Data Rate  
10.5  
1. Including in rush current. Maximum module current ramp rate is 100 mA/ms.  
Transmitter Optical Specifications (Topr= -5 to 70oC, Vcc5=5V±5%, Vcc3 = 3.3V ±5%)  
Parameter  
Symbol  
Po, Avg  
ER  
Min  
-1  
Typ  
Max  
Units  
dBm  
dB  
Notes  
Average Launch Power  
Extinction Ratio  
2.0  
2
8.2  
Output Center Wavelength  
Output Spectrum Width  
Side Mode Suppression Ratio  
Transmitter and Dispersion  
Penalty @ 800 ps/nm  
Relative Intensity Noise  
Eye Mask  
l c  
1530  
1565  
1
nm  
σl  
nm  
-20 dB width  
SMSR  
TDP  
30  
dB  
3
dB  
RIN  
-130  
-30  
21  
dB/Hz  
dBm  
dB  
IEEE 802.3ae  
Average Launch Power of OFF  
Transmitter  
Optical Return Loss Tolerance  
2. Output power is power coupled into a 9/125 mm single-mode fiber.  
Receiver Optical Specifications (Topr= -5 to 70oC, Vcc5=5V±5%,Vcc3 = 3.3V ±5%)  
Parameter  
Sensitivity @ 10.3125 Gb/s  
Receiver Overload  
Symbol  
Sen1  
Min  
Typ  
Max  
Units  
dBm  
dBm  
dBm  
dBm  
dB  
Notes  
-16  
3
PMAX  
-1  
---  
---  
---  
---  
---  
LOS -- Deasserted  
LOSD  
LOSA  
-22  
---  
Transition: low to high  
Transition: high to low  
LOS -- Asserted  
-28  
0.5  
LOS -- Hysteresis  
Wavelength of Operation  
l c  
1260  
1580  
-26  
nm  
Optical Return Loss  
ORL  
dB  
3. Average received power; Measured at 1530 to 1565 nm; BER < 10-12 and PRBS 231-1.  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
3
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
Electrical Characteristics  
Parameter  
Symbol  
Min  
Typ  
Max  
Units  
Gb/s  
ppm  
Notes  
High-Speed Signal (CML) Interface Specification  
Input Data Rate  
9.95328  
10.3125  
±20  
4
5
4
5
Input Date Rate Tolerance  
±100  
Ω
Differential Input Impedance  
Differential Data Input Amplitude  
Output Data Rate  
Rin  
100  
120  
340  
820  
850  
mVpp  
Gb/s  
8, Internally AC coupled  
9.95328  
10.3125  
±100  
4
5
Output Date Rate Tolerance  
Differential Output Impedance  
Differential Data Output  
Amplitude  
ppm  
Ω
4,5  
Rout  
100  
mVpp  
6, Internally AC coupled  
Low-Speed Signal (LVTTL) Interface Specification  
Input High Voltage  
2.0  
GND  
2.4  
Vcc  
0.8  
V
V
V
V
Input Low Voltage  
Output High Voltage  
Vcc  
0.5  
Output Low Voltage  
GND  
Reference Clock (LVPECL) Interface Specification  
No reference clock  
4. 10GBASE-EW.  
5. 10GBASE-ER.  
6. The differential input and output amplitudes are per XFP MSA mask at points Band C.  
Transceiver Timing Characteristics  
Parameter  
TX_DIS Assert Time  
TX_DIS Negate Time  
Time to Initialize  
Symbol  
Min  
Typ  
Max  
10  
2
Units  
ms  
Notes  
t_off  
t_on  
ms  
ms  
ms  
ms  
t_init  
300  
200  
500  
100  
300  
1
Interrupt Assert Delay  
Interrupt Negate Delay  
P_Down/PST Assert Delay  
P_Down Nagate Delay  
Mod_NR Assert Delay  
Mod_NR Negate Delay  
Mod_Desel Assert Time  
Mod_Desel De-Assert Time  
P_Down Reset Time  
interrupt_on  
interrupt_off  
P_Down/RST_on  
P_Down/RST_off  
Mod_nr_on  
Mod_nr_off  
T_Mod_Desel  
T_Mod_Sel  
T_reset  
ms  
ms  
ms  
ms  
ms  
ms  
ms  
1
2
2
10  
0
RX_LOS Assert Delay  
RX_LOS Negate Delay  
Serial ID Clock Rate  
T_Los_on  
T_Los_off  
fSCL  
100  
100  
400  
ms  
ms  
kHz  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
4
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
MANAGEMENT INTERFACE  
The structure of the memory map is shown in Figure 1, which is accessible over a 2-wire serial interface at the 8-bit  
address 1010000X (A0h). The normal 256 byte I2C address space is divided into low and upper blocks of 128 Bytes. The  
lower block of 128 Bytes is always directly available and is used for the diagnostics and control function. Multiple blocks of  
memories are available in the upper 128 Bytes of the address space. These are individually addressed through a table select  
Byte which the user enters into a location in the lower address space. Thus, there is a total available address space of 128*256  
= 32 Kbytes in this upper memory space. The contents of Table 01h are listed in Table 1 below. Please refer SFF INF-8077i  
(Revision 4.5) for detailed information.  
Figure 1. 2-wire Serial Digital Diagnostic Memory Map  
Table 1 Monitoring Specification  
Data Address  
96 ~ 97  
Parameter  
Temperature  
Accuracy  
± 3oC  
98 ~ 99  
Reserved  
100 ~ 101  
102 ~ 103  
104 ~ 105  
106 ~ 107  
Tx Bias  
Tx Power  
Rx Power  
Vcc3  
± 10%  
± 2dB  
± 2dB  
± 3%  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
5
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
CONNECTION DIAGRAM  
Table 3 PIN Description  
PIN  
1
Logic  
Signal Name  
GND  
Description  
Note  
1
3
Module Ground  
2
VEE5  
-5.2V Power Supply (Not required)  
Module De-select; When held low allows module to respond to 2-wire serial interface  
3
LVTTL-I  
Mod_Desel  
Interrupt; Indicates presence of an important condition which can be read over the  
2wire serial interface  
4
LVTTL-O  
2
Interrupt  
5
6
7
8
9
LVTTL-I  
TX_DIS  
VCC5  
GND  
Transmitter Disable; Turns off transmitter laser output  
+5V Power Supply  
3
1
Module Ground  
VCC3  
VCC3  
+3.3V Power Supply  
+3.3V Power Supply  
10 LVTTL-I/O SCL  
11 LVTTL-I/O SDA  
Serial 2-wire interface clock  
Serial 2-wire interface data line  
Indicates Module is not present. Grounded in the Module  
Module Not Ready; Indicating Module Operational Fault  
Receiver Loss Of Signal Indicator  
Module Ground  
2
2
2
2
2
1
1
12 LVTTL-O  
Mod_Abs  
13 LVTTL-O  
Mod_NR  
RX_LOS  
GND  
14 LVTTL-O  
15  
16  
GND  
Module Ground  
17 CML-O  
RD-  
Receiver Inverted Data Output  
Receiver Non-Inverted Data Output  
Module Ground  
18 CML-O  
RD+  
19  
20  
GND  
1
3
VCC2  
+1.8V Power Supply (Not required)  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
6
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
21 LVTTL-I  
P_Down/RST Power down; When high, requires the module to limit power consumption to 1.5W or  
below. 2-Wire serial interface must be functional in the low power mode.  
Reset; The falling edge initiates a complete reset of the module including the 2-wire  
serial interface, equivalent to a power cycle.  
22  
VCC2  
+1.8V Power Supply (Not required)  
Module Ground  
3
1
4
23  
GND  
24 PECL-I  
RefCLK+  
Reference Clock Non-Inverted Input, AC coupled on the host board. (Not used.  
Internally terminated to 50 ohm (100 ohm diff.))  
Reference Clock Inverted Input, AC coupled on the host board. (Not used. Internally  
terminated to 50 ohm (100 ohm diff.))  
Module Ground  
25 PECL-I  
RefCLK-  
4
26  
GND  
GND  
TD-  
1
1
27  
Module Ground  
28 CML-I  
29 CML-I  
30  
Transmitter Inverted Data Input  
TD+  
GND  
Transmitter Non-Inverted Data Input  
Module Ground  
1
1. Module ground pins GND are isolated from the module case and chassis ground within the module.  
2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board.  
3. These PINs are open within module.  
4. A Reference Clock input is not required. If present, it will be ignored.  
MECHANICAL SPECIFICATION (UNITS IN MM)  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
7
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
RECOMMENDED POWER CIRCUIT SCHEMATIC  
Host Board  
VCC5  
Optional  
Host +5V  
4.7μH  
22μF  
22μF  
22μF  
22μF  
0.1μF  
0.1μF  
VCC3  
Host +3.3V  
4.7μH  
4.7μH  
4.7μH  
0.1μF  
0.1μF  
0.1μF  
0.1μF  
XFP Module  
VCC2  
0.1μF  
Optional  
Host +1.8V  
VEE5  
0.1μF  
Optional  
Host -5.2V  
RECOMMENDED INTERFACE CIRCUIT  
XFP module  
Host Board  
SerDat Out+  
TD +  
Z=50Ω  
CML  
100Ω  
CML  
TD -  
SerDat Out-  
Z=50Ω  
SerDat In+  
SerDat In-  
RD +  
Z=50Ω  
Z=50Ω  
CML  
CML  
100Ω  
RD -  
REFCLKP  
Vcc(+3.3V)  
100Ω  
4.7K to 10KΩ  
REFCLKN  
RX_LOS  
INTERRUPT  
SDA  
VCC(+3.3V)  
SCL  
MOD_NR  
MOD_abs  
TX_DIS  
10KΩ  
GND  
MOD_DeSel  
P_Down/RST  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
8
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
Table 2 Serial ID Memory Contents (Table 01h)  
Field  
Address Size  
(Byte)  
Name of Filed  
Description  
Hex  
128  
1
Identifier  
XFP  
06  
power consumption <3.5W, no Ref Colck  
129  
130  
131~138  
139  
140  
141  
142  
143  
144  
145  
1
1
8
1
1
1
1
1
1
1
1
1
Ext. Identifier  
Connector type  
Transceiver  
Encoding  
BR-Min  
required  
LC connector  
10GBASE-ER/EW, 10GFC 1200-SM-LL-L  
64B66B/8B10B  
9.9Gbps  
10.5Gbps  
60 Km  
0 m  
90  
07  
22 40 00 00 00 00 00 00  
C0  
63  
69  
3C  
00  
00  
00  
BR-Max  
length (SMF)-Km  
Length (E-50µm)  
Length (50 µm)  
Length (62.5 µm)  
Length (Copper)  
Device Tech  
0 m  
0 m  
0 m  
146  
147  
00  
74  
1550 EML, PIN detector  
4F 50 54 4F 57 41 59 20  
20 20 20 20 20 20 20 20  
CDR supports 9.953G ~ 10.5G & XFI Loopback E1  
00 0E FA  
148~163  
164  
165~167  
16  
1
3
Vendor name  
CDR Support  
Vendor OUI  
OPTOWAY  
58 50 53 2D 32 33 36 30  
57 47 20 20 20 20 20 20  
xx xx  
168~183  
184~185  
186~187  
16  
2
2
Vendor PN  
Vendor rev  
Wavelength  
Wavelength  
Tolerance  
XPS-2360WG  
ASCII (31 61means 1a revision)  
1550 nm  
79 18  
188~189  
190  
191  
2
1
1
+/- 20 nm  
70deg  
0F A0  
46  
Max Case Temp  
CC_BASE  
Check sum of Byte 128 -- 190  
3.5 Wmax, 1.5W pd_max , 750mA 3.3V, 500  
mA 5V  
192~195  
196~211  
212~219  
220  
4
16  
8
Power Supply  
Vendor SN  
AF 96 A8 00  
xx xx xx xx xx xx xx xx  
xx xx xx xx xx xx xx xx  
ASCII  
ASCII Year (2 Byte), Month (2 Byte), Day (2  
Byte)  
Date code  
Diagnostic  
Monitoring Type  
xx xx xx xx xx xx 20 20  
08  
1
No BER Support, Average Power  
Optional Soft TX_DISABLE implemented,  
Optional Soft P_down implemented  
AUX1 for Vcc3.  
221  
222  
223  
1
1
1
Enhanced Options  
Aux Monitoring  
CC_EXT  
60  
70  
Check sum of Byte 192 -- 222  
224~255  
32  
Vendor Specific  
Reserved  
Note: Specifications subject to change without notice.  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  
9
Optoway  
XPS-2360WG  
***********************************************************************************************************************************************************************  
REVISION HISTORY  
Version  
Subject  
Release Date  
1.0  
2.0  
Initial datasheet  
2008/8/1  
2009/7/1  
Add a) XPS-2360BWG for -5 to 85oC operating  
b) XPS-2360AWG for -40 to 85oC operating  
**********************************************************************************************************************************************************************  
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303  
Tel: 886-3-5979798  
Fax: 886-3-5979737  
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw 7/1/2009 V2.0  

相关型号:

XPS-2371W-CXX0G

10Gbps / 70 km / CWDM XFP Single-Mode Optical Transceiver for OC-192 / 10GbE / 10G FC
OPTOWAY

XPS-2371W-CXXG

10Gbps / 70 km / CWDM XFP Single-Mode Optical Transceiver for OC-192 / 10GbE / 10G FC
OPTOWAY

XPS-2380AMWG

80km / 1550 nm / 10G Multirate XFP Single-Mode Optical Transceiver
OPTOWAY

XPS-2380AWG

10Gbps / 80km / 1550 nm XFP Single-Mode Optical Transceiver for 10GbE / 10G FC
OPTOWAY

XPS-2380BMWG

80km / 1550 nm / 10G Multirate XFP Single-Mode Optical Transceiver
OPTOWAY

XPS-2380BWG

10Gbps / 80km / 1550 nm XFP Single-Mode Optical Transceiver for 10GbE / 10G FC
OPTOWAY

XPS-2380MWG

80km / 1550 nm / 10G Multirate XFP Single-Mode Optical Transceiver
OPTOWAY

XPS-2380MWG_09

80km / 1550 nm / 10G Multirate XFP Single-Mode Optical Transceiver
OPTOWAY

XPS-2380WG

10Gbps / 80km / 1550 nm XFP Single-Mode Optical Transceiver for 10GbE / 10G FC
OPTOWAY

XPS-2380WG_09

10Gbps / 80km / 1550 nm XFP Single-Mode Optical Transceiver for 10GbE / 10G FC
OPTOWAY

XPS-2381MW-D21G

10G Multirate / 80 km / 100 GHz DWDM XFP Single-Mode Optical Transceiver
OPTOWAY

XPS-2381MW-D22G

10G Multirate / 80 km / 100 GHz DWDM XFP Single-Mode Optical Transceiver
OPTOWAY