DBE1-1211 [PAIRUI]
DC-DC Converter;型号: | DBE1-1211 |
厂家: | PAIRUI GROUP INC. |
描述: | DC-DC Converter |
文件: | 总3页 (文件大小:362K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC-DC Converter
SIP-Package
DBE-1 SERIES, 1WATT, 1KVDC, UNREGULATED
FEATURES:
ꢀ
ꢀ
ꢀ
ꢀ
3 years warranty
1000Vdc isolation voltage
Operating temperature range -40°C to +85°C
Compact size
Output current
(mA)
Input voltage
(Vdc)
Output voltage
Efficiency
Typ.
Model
(Vdc)
Min.
Max.
3.3
5
30
20
300
200
110
83
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
80%
DBE1-0310
DBE1-0311
DBE1-0312
DBE1-0313
DBE1-0314
DBE1-0315
DBE1-0510
DBE1-0511
DBE1-0512
DBE1-0513
DBE1-0514
DBE1-0515
DBE1-1210
DBE1-1211
DBE1-1212
DBE1-1213
DBE1-1214
DBE1-1215
DBE1-2410
DBE1-2411
DBE1-2412
DBE1-2413
DBE1-2414
DBE1-2415
9
11
3.3(2.97~3.63)
12
15
24
3.3
5
8.3
6.8
4.2
30
68
42
300
200
110
83
20
9
11
5(4.5~5.5)
12
15
24
3.3
5
8.3
6.8
4.2
30
68
42
300
200
110
83
20
9
11
12(10.8~13.2)
12
15
24
3.3
5
8.3
6.8
4.2
30
68
42
300
200
110
83
20
9
11
24(21.6~26.4)
12
15
24
8.3
6.8
4.2
68
42
Notes: other input and output models may available on request.
www.pairuigroup.com
Date: 05/06/2014
Page: 1/3
DC-DC Converter
SIP-Package
DBE-1 SERIES, 1WATT, 1KVDC, UNREGULATED
ELECTRICAL
Line regulation
---
± 1.2%
15% max.
Load regulation
Ripple and noise
Isolation voltage
Operating temperature range
MTBF
10% ~ 100% full load
---
---
---
---
100mVp-p max.
1000Vdc
-40°C to +85°C
3.5x106Hrs
Notes: All the data in this article are under test with “TA+25°C, humidity<75%, rated input and rated load”
mode.
MECHANICAL
CONNECTION
6.0
(0.236)
11.5
(0.453)
PIN #
SINGLE
GND
+Vin
-Vo
1
2
3
4
10.0
(0.394)
4.1
(0.161)
+Vo
1.94
(0.076)
0.9
(0.035)
Note:
* Unit is mm(inch).
TEMPERATURE PROFILE
www.pairuigroup.com
Date: 05/06/2014
Page: 2/3
DC-DC Converter
SIP-Package
DBE-1 SERIES, 1WATT, 1KVDC, UNREGULATED
CAPACITIVE LOADS SELECTION
Single Output
Dual Output
Vin
Cin
Cout
(μF)
Cout
(μF)
Voltage
(Vdc)
5
Voltage
(Vdc)
±5
(Vdc)
(μF)
3.3/5
12
4.7
2.2
1
10
4.7
2.2
1
4.7
2.2
1
9
±9
24
12
±12
±15
-
-
15/24
0.47
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
In order to ensure the efficiency and dependability of the module, the minimum specified load must be less than 10% of
rated load. If the output power is low, we recommend to add an external 10% loading resistor in parallel.
FUSE: depends on the actual input current;
TVS: depends on the actual input voltage;
Recommended capacitor:C1, C2, C5,about 0.1uF; for C6,C7,please check the capacitive load; C3,C4:2KV/1nF.
www.pairuigroup.com
Date: 05/06/2014
Page: 3/3
相关型号: