LLU60-C1400 [PAIRUI]
Constant Current LED Power Supplies;型号: | LLU60-C1400 |
厂家: | PAIRUI GROUP INC. |
描述: | Constant Current LED Power Supplies |
文件: | 总8页 (文件大小:545K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
2017-V1.0-0415
Specifications
Constant Current LED Power Supplies
LL Series, 60W
PAIRUI ELECTRONICS
No. 545 Museum Road
Yangzhou, Jiangsu
China 225009
2017
Tel: 86 (514) 8279 1592
Fax: 86 (514) 8769 3159
led power supplies
PRODUCT SPECIFICATION
LED Power Supplies for Indoor Use
LL SERIES, 60WATT, IP20 RATING
Features
3 Year Warranty
Wide Input Voltage Range: 100~240Vac
Constant Current Output Mode
Waterproof Rating IP20
Built-in Active Power Factor Correction
Short Circuit, Over Voltage, and Over Current Protections
Applications
√
√
√
√
Panel Light
Down Light
Recessed Light
√
Cabinet Light
Other Indoor used Lights
Electrical
-
LL U 60
C 1400
Output Current(mA)
Output Mode
C = Constant Current Mode
Nominal Output Power(W)
Input Voltage Range
U = 100-240Vac
Series Name
PAIRUI ELECTRONICS
www.pairuigroup.com
Page:1/6
Updated 2017-V1.0-0415
led power supplies
PRODUCT SPECIFICATION
Electrical
Nominal
PartꢀNumber
Output Current
Output Voltage
No Load
Output Voltage
Ripple
Certificate
Input Voltage
LLU60-C1400
LLU60-C1500
48V
48V
CE
CE
100-240VAC
1400mA(27-42V)
1500mA(27-42V)
50%
50%
100-240VAC
NOTE: Other output models are may available on request.
PAIRUI ELECTRONICS
www.pairuigroup.com
Page:2/6
Updated 2017-V1.0-0415
led power supplies
PRODUCT SPECIFICATION
INPUT
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Input frequency
Input current
Inrush current
Power factor(PF)
Efficiency
47
63
Hz
Full load, Vin=110Vac
Full load, Vin=220Vac
0.8
0.4
A
A
Cold start, Vin=230Vac
25
A
Full load, Vin=110Vac
Full load, Vin=220Vac
0.98
0.95
Full load, Vin=110Vac
Full load, Vin=220Vac
88
89
%
%
Surge voltage
L-N
2
KV
PAIRUI ELECTRONICS
www.pairuigroup.com
Page:3/6
Updated 2017-V1.0-0415
led power supplies
PRODUCT SPECIFICATION
OUTPUT
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Output current accuracy
Line regulation
5
5
5
%
%
%
%
S
Vin from 100Vac to 240Vac
Vout from min. to max.
Turning on
Load regulation
Output current overshoot
Turn-on delay time
10
20
Cold start, power on
2
Ripple
THD
50%Io
mAp-p
Full load, Vin=220Vac
%
Protection
Short circuit
Over voltage
Over current
In hiccup mode, it will recover automatically after fault condition is removed
110-150% Vout, it will recover automatically after fault condition is removed
In hiccup mode, it will recover automatically after fault condition is removed
PAIRUI ELECTRONICS
www.pairuigroup.com
Page:4/6
Updated 2017-V1.0-0415
led power supplies
PRODUCT SPECIFICATION
Environment
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Ambient operating
temperature
Startup at rated voltage
Non condensing
-25
20
+50
90
℃
%
℃
℃
Operating relative humidity
Storageꢀtemperature
Humidity 10 ~ 95% RH
Hot-spotꢀonꢀcase
-40
+80
+75
Maximum case temperature
Fullꢀload, 220Vac input, 25℃ꢀambientꢀ
temperature
MTBF
400
Khrs
Waterproof rating
Dimension(LxWxH)
IP20
285.0 x 30.0 x 21.0mm
Weight
190g
Safety/EMC
Safety
EMC
Design refer to EN61347-1, EN61347-2-13
Compliance to EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
NOTE: Unless otherwise specified, all the above parameters are measured at ambient temperature of
25℃ꢀandꢀVin=100Vac to 240Vac.
PAIRUI ELECTRONICS
www.pairuigroup.com
Page:5/6
Updated 2017-V1.0-0415
led power supplies
PRODUCT SPECIFICATION
Mechanical
285
275
5.5
5.5
R2.1
5
5
Unit: mm
Electrical Curve
DERATING CURVE
100
90
80
70
60
50
40
30
-25 -15
0
10 20 30 40 50 60 70
Temperature(℃)
PAIRUI ELECTRONICS
www.pairuigroup.com
Page:6/6
Updated 2017-V1.0-0415
led power supplies
PRODUCT SPECIFICATION
Update Record
Date
Version
Updated Content
Updated By
Approved By
2017/04/15 2017-V1.0-0415
File created
相关型号: