ACT112V [PANASONIC]

Electromechanical Relay, SPDT, 16VDC (Coil), 20A (Contact), 14VDC (Contact), Random, DC Output;
ACT112V
型号: ACT112V
厂家: PANASONIC    PANASONIC
描述:

Electromechanical Relay, SPDT, 16VDC (Coil), 20A (Contact), 14VDC (Contact), Random, DC Output

光电二极管
文件: 总6页 (文件大小:1462K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SMALL & SLIM  
AUTOMOTIVE RELAY  
CT RELAYS (ACT)  
FEATURES  
TYPICAL APPLICATIONS  
• Terminal layout for simplifying PC  
board pattern design  
• Power windows  
• Auto door lock  
• Capable of 25A high-capacity load  
switching with compact size  
• Plastic sealed type  
• Power sunroof  
• Electrically powered mirrors  
• Powered seats  
• Lift gates  
• Slide door closers, etc. (for DC motor  
forward/reverse control circuits)  
ORDERING INFORMATION  
ACT  
Contact arrangement  
1: 1 Form C  
2: 1 Form C×2 (8 terminal)  
5: 1 Form C×2 (10 terminal)  
Coil voltage, DC  
12: 12 V  
TYPES  
Contact arrangement  
Coil voltage  
Part No.  
ACT112  
ACT212  
ACT512  
1 Form C  
1 Form C 2 (8 terminals type)  
1 Form C 2 (10 terminals type)  
12 V DC  
Standard packing; 1 Form C: Carton (tube) 30pcs. Case 1,500pcs.  
1 Form C 2: Carton (tube) 30pcs. Case 900pcs.  
RATING  
1. Coil data  
Nominal operating  
current  
[10%] (at 20C 68F)  
Nominal operating  
power  
(at 20C 68F)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20C 68F)  
Drop-out voltage  
(at 20C 68F)  
Coil resistance  
[10%] (at 20C 68F)  
Usable voltage range  
10 to 16V DC  
Max. 7.2 V DC  
(Initial)  
Min. 1.0 V DC  
(Initial)  
12V DC  
66.7 mA  
180  
800 mW  
Note: Other pick-up voltage types are also available. Please contact us for details.  
ds_61205_en_ct: 010113J  
1
CT (ACT)  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
Contact resistance (Initial)  
1 Form C 2, 1 Form C  
Contact  
Rating  
N.O.: Typ 7m, N.C.: Typ 10m(By voltage drop 6V DC 1A)  
Ag alloy (Cadmium free)  
Contact material  
Nominal switching capacity (resistive load)  
N.O.: 20 A 14V DC, N.C.: 10 A 14V DC  
N.O.: 25 A for 1 hour, 35 A for 2 minutes at 20C 68F  
20 A for 1 hour, 30 A for 2 minutes at 85C 185F  
Max. carrying current (14V DC)*3  
Nominal operating power  
800 mW  
Min. switching capacity (resistive load)*1  
1 A 14V DC  
Insulation resistance (Initial)  
Min. 100 M(at 500V DC, Measurement at same location as “Breakdown voltage” section.)  
500 Vrms for 1 min. (Detection current: 10mA)  
Between open contacts  
Breakdown voltage  
(Initial)  
Electrical  
Between contacts and coil  
500 Vrms for 1 min. (Detection current: 10mA)  
characteristics  
Operate time (at nominal voltage)  
Release time (at nominal voltage)  
Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)  
Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)  
Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)  
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)  
10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10s)  
Functional  
Shock resistance  
Destructive  
Mechanical  
characteristics  
Functional  
10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},  
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours  
Vibration resistance  
Destructive  
Mechanical  
Min. 107 (at 120 cpm)  
<Resistive load>  
Min. 105 (at nominal switching capacity, operating frequency: 1s ON, 9s OFF)  
<Motor load>  
N.O. side: Min. 2 105 (at Inrush 25A, Steady 5A 14 V DC),  
Min. 105 (at 25A 14 V DC motor lock condition)  
N.C. side: Min. 2 105 (at brake current 20A 14 V DC) (operating frequency: 0.5s ON, 9.5s  
OFF)  
Expected life  
Conditions  
Electrical  
Ambient temperature: –40C to +85C –40F to +185F,  
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions for operation, transport and storage*2  
Max. operating speed  
6 cpm (at nominal switching capacity)  
Mass  
Twin type: approx. 8 g .28 oz, 1 Form C type: approx. 4 g .14 oz  
Notes:  
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.  
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport  
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.  
Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).  
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.  
If the relay is used continuously for long periods of time with coils on both sides in an energized condition, breakdown might occur due to abnormal heating depending on  
the carrying condition. Therefore, please inquire when using with a circuit that causes an energized condition on both sides simultaneously.  
REFERENCE DATA  
1-(1). Coil temperature rise (at room  
temperature)  
1-(2). Coil temperature rise (at 85C 185F)  
2. Max. switching capability (Resistive load,  
initial)  
Sample: ACT212, 3pcs.  
Contact carrying current: 0A, 10A, 20A  
Ambient temperature: 85C 185F  
Sample: ACT212, 3pcs.  
Contact carrying current: 0A, 10A, 20A  
Ambient temperature: Room temperature  
(when coil powered on one side)  
140  
(when coil powered on one side)  
140  
(N.O. side: room temperature)  
60  
20A  
120  
100  
80  
120  
50  
40  
20A  
10A  
0A  
100  
10A  
80  
0A  
30  
20  
10  
0
60  
40  
20  
0
60  
40  
20  
0
12  
14  
16  
12  
14  
16  
0
10  
20  
30  
40  
50  
Coil applied voltage, V  
Coil applied voltage, V  
Switching current, A  
ds_61205_en_ct: 010113J  
2
CT (ACT)  
5. Distribution of operate and release time  
Sample: ACT212, 40pcs.  
3. Ambient temperature and operating voltage  
range  
4. Distribution of pick-up and drop-out voltage  
Sample: ACT212, 40pcs.  
* Without diode  
35  
40  
35  
50  
Operate time  
Pick-up voltage  
Release time  
20  
Drop-out voltage  
40  
30  
25  
25  
20  
15  
10  
5
30  
20  
20  
Operating voltage range  
15  
10  
5
10  
Pick-up voltage (Cold start)  
0
01.0  
0 0  
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0  
1
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5  
Voltage, V  
40 20  
0
20 40 60 8085 100 120  
Operate and release time, ms  
Ambient temperature, °C  
6-(1). Electrical life test (Motor free)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Sample: ACT212, 3pcs.  
Load: Inrush 25A, steady 5A  
Brake current: 13A 14V DC,  
Power window motor actual load (free condition)  
Operating frequency: ON 0.5s, OFF 9.5s  
Ambient temperature: Room temperature  
Circuit:  
50  
40  
30  
20  
10  
Contact welding: 0 time  
Miscontact: 0 time  
8
Pick-up voltage  
Sample  
Max.  
X
Min.  
6
4
Drop-out voltage  
Max.  
X
Min.  
10  
2
0
Max.  
X
M
Min.  
0
0
10  
20  
0
10  
20  
No. of operations, × 104  
No. of operations, × 104  
Load current waveform  
Inrush current: 25A, Steady current: 6A  
Brake current: 13A  
10A  
100ms  
ds_61205_en_ct: 010113J  
3
CT (ACT)  
6-(2). Electrical life test (Motor lock)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Sample: ACT212, 3pcs.  
Load: 25A 14V DC  
50  
40  
30  
20  
10  
10  
Power window motor actual load (lock condition)  
Switching frequency: ON 0.5s, OFF 9.5s  
Ambient temperature: Room temperature  
Circuit:  
Contact welding: 0 time  
Miscontact: 0 time  
8
Sample  
Pick-up voltage  
6
Max.  
X
Min.  
4
Drop-out voltage  
Max.  
X
Min.  
Max.  
X
Min.  
2
0
M
0
0
5
10  
0
5
10  
No. of operations, × 104  
No. of operations, × 104  
Load current waveform  
5A  
100ms  
6-(3). Electrical life test (Motor lock)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Sample: ACT212, 3pcs.  
Load: 20A 14V DC,  
10  
9
50  
40  
30  
20  
10  
0
door lock motor actual load (Lock condition)  
Switching frequency: ON 0.3s, OFF 19.7s  
Ambient temperature: Room temperature  
8
Circuit:  
Sample  
7
6
5
4
Pick-up voltage  
Drop-out voltage  
Max.  
X
Min.  
Side1  
M
M
M
M
M M  
3
2
Max.  
X
Min.  
Side2  
Max.  
1
0
X
Min.  
0
5
10  
0
5
10  
No. of operations, × 104  
No. of operations, × 104  
Relay 1  
Relay 2  
0.3s  
9.7s  
0.3s  
9.7s  
20s (1 cycle)  
Load current waveform  
5A  
100ms  
ds_61205_en_ct: 010113J  
4
CT (ACT)  
DIMENSIONS (mm inch)  
Download  
C
A
D
D
a
t
a
from our Web site.  
1. Twin type (8 terminals)  
External dimensions  
PC board pattern (Bottom view)  
CAD Data  
17.4  
.685  
9.5  
.374  
6
14  
.551  
.236  
4.3  
.169  
2.5  
3
13.5  
.531  
0.4  
.098  
.118  
6.8  
.268  
4.3  
.169  
Max. 1.0  
.039  
3.15  
.124  
.016  
+0.1  
0
15  
.591  
4×1.1 dia.  
4×.043+00.04 dia.  
3.5  
.138  
+0.1  
0
4×1.4 dia.  
*A  
4×.055+00.04 dia.  
0.4  
.016  
1
.039  
1
.039  
0.8  
.031  
0.3  
.012  
0.4 0.4  
.016 .016  
Tolerance: 0.1 .004  
Pre-soldering  
1.25  
.049  
9.5  
.374  
6
.236  
Schematic (Bottom view)  
1
.039  
4.3  
.169  
COIL  
2.5  
.098  
COM  
NC  
3
6.8  
.268  
.118  
3.15  
.124  
4.3  
.169  
NO  
Dimension:  
Max. 1mm .039 inch:  
1 to 3mm .039 to .118 inch: 0.2 .008  
Min. 3mm .118 inch: 0.3 .012  
Tolerance  
0.1 .004  
COIL  
COM  
15  
.591  
1.45  
.057  
* Dimensions (thickness and width) of terminal is measured before pre-soldering.  
Intervals between terminals is measured at A surface level.  
2. Twin type (10 terminals)  
External dimensions  
PC board pattern (Bottom view)  
CAD Data  
17.4  
.685  
14  
.551  
9.5  
.374  
6
.236  
4.3  
3.15  
.124  
.169  
2.5  
.098  
13.5  
.531  
0.4  
.016  
0.65  
.026  
3.15  
.124  
6.8  
.268  
Max. 1.0  
.039  
4.3  
.169  
+0.1  
0
4×1.1 dia.  
4×.043+0.04  
dia.  
0
3.5  
.138  
15  
.591  
0.65  
.026  
*A  
+0.1  
0
1
.039  
6×1.4 dia.  
6×.055+0.04  
dia.  
0
0.4  
.016  
1
.039  
0.4 0.4  
0.8  
0.3  
.012  
.016 .016  
.031  
Tolerance: 0.1 .004  
9.5  
1.25  
.049  
Pre-soldering  
.374  
6
.236  
Schematic (Bottom view)  
4.3  
3.15  
.124  
NO  
.169  
COIL  
2.5  
.098  
NC  
0.65  
.026  
3.15  
.124  
COM  
6.8  
.268  
Dimension:  
Max. 1mm .039 inch:  
Tolerance  
0.1 .004  
4.3  
.169  
NO  
COIL  
1.45  
.057  
NC  
1 to 3mm .039 to .118 inch: 0.2 .008  
Min. 3mm .118 inch: 0.3 .012  
COM  
0.65  
.026  
15  
.591  
1
.039  
* Dimensions (thickness and width) of terminal is measured before pre-soldering.  
Intervals between terminals is measured at A surface level.  
ds_61205_en_ct: 010113J  
5
CT (ACT)  
3. Slim 1c type  
External dimensions  
PC board pattern (Bottom view)  
CAD Data  
17.4  
.685  
7.2  
.283  
3×1.4 dia.  
3×.055 dia.  
9.5  
.374  
6
.236  
4.3  
.169  
3.15  
.124  
13.5  
.531  
+0.1  
0
2×1.1 dia.  
0.4  
.016  
Max. 1.0  
.039  
0.65  
.026  
2×.043+00.04 dia.  
15  
.591  
3.5  
.138  
Tolerance: 0.1 .004  
*A  
0.4  
0.8  
.031  
1
1
.016  
.039  
Schematic (Bottom view)  
0.4  
0.4  
0.3  
.012  
.039  
.016 .016  
9.5  
.374  
1.25  
.049  
Pre-soldering  
NO  
6
COIL  
.236  
1
.039  
NC  
COM  
Dimension:  
Max. 1mm .039 inch:  
Tolerance  
0.1 .004  
4.3  
.169  
3.15  
.124  
1 to 3mm .039 to .118 inch: 0.2 .008  
Min. 3mm .118 inch: 0.3 .012  
1.45  
.057  
0.65  
.006  
15  
.591  
* Dimensions (thickness and width) of terminal is measured before pre-soldering.  
Intervals between terminals is measured at A surface level.  
EXAMPLE OF CIRCUIT  
Forward/reverse control circuits of DC motor for power windows  
NO  
NC  
NO  
NC  
COM  
COM  
12 V DC  
M
SW A  
SW B  
M
: Power window motor  
For Cautions for Use, see Relay Technical Information.  
ds_61205_en_ct: 010113J  
6

相关型号:

ACT1210

Common Mode Filters For automobile signal line
TDK

ACT1210-101-2P

Data Line Filter,
TDK

ACT1210-101-2P-TL00

Data Line Filter, 2 Function(s), 80V, 0.15A, ROHS COMPLIANT, EIA STD PACKAGE SIZE 1210, 4 PIN
TDK

ACT1210-110-2P

Data Line Filter,
TDK

ACT1210-110-2P-TL00

Data Line Filter, 2 Function(s), 80V, 0.3A, ROHS COMPLIANT, EIA STD PACKAGE SIZE 1210, 4 PIN
TDK

ACT1210-220-2P

Data Line Filter,
TDK

ACT1210-220-2P-TL00

Common Mode Filters For automobile signal line
TDK

ACT1210-510-2P

Data Line Filter,
TDK

ACT1210-510-2P-TL00

Data Line Filter, 2 Function(s), 80V, 0.2A, ROHS COMPLIANT, EIA STD PACKAGE SIZE 1210, 4 PIN
TDK

ACT1210D-101-2P-TL00

共模滤波器/扼流圈
TDK

ACT1210D-131-2P-TL00

共模滤波器/扼流圈
TDK

ACT1210D-510-2P-TL00

共模滤波器/扼流圈
TDK