ACT112V [PANASONIC]
Electromechanical Relay, SPDT, 16VDC (Coil), 20A (Contact), 14VDC (Contact), Random, DC Output;型号: | ACT112V |
厂家: | PANASONIC |
描述: | Electromechanical Relay, SPDT, 16VDC (Coil), 20A (Contact), 14VDC (Contact), Random, DC Output 光电二极管 |
文件: | 总6页 (文件大小:1462K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SMALL & SLIM
AUTOMOTIVE RELAY
CT RELAYS (ACT)
FEATURES
TYPICAL APPLICATIONS
• Terminal layout for simplifying PC
board pattern design
• Power windows
• Auto door lock
• Capable of 25A high-capacity load
switching with compact size
• Plastic sealed type
• Power sunroof
• Electrically powered mirrors
• Powered seats
• Lift gates
• Slide door closers, etc. (for DC motor
forward/reverse control circuits)
ORDERING INFORMATION
ACT
Contact arrangement
1: 1 Form C
2: 1 Form C×2 (8 terminal)
5: 1 Form C×2 (10 terminal)
Coil voltage, DC
12: 12 V
TYPES
Contact arrangement
Coil voltage
Part No.
ACT112
ACT212
ACT512
1 Form C
1 Form C 2 (8 terminals type)
1 Form C 2 (10 terminals type)
12 V DC
Standard packing; 1 Form C: Carton (tube) 30pcs. Case 1,500pcs.
1 Form C 2: Carton (tube) 30pcs. Case 900pcs.
RATING
1. Coil data
Nominal operating
current
[10%] (at 20C 68F)
Nominal operating
power
(at 20C 68F)
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Usable voltage range
10 to 16V DC
Max. 7.2 V DC
(Initial)
Min. 1.0 V DC
(Initial)
12V DC
66.7 mA
180
800 mW
Note: Other pick-up voltage types are also available. Please contact us for details.
ds_61205_en_ct: 010113J
1
CT (ACT)
2. Specifications
Characteristics
Item
Specifications
Arrangement
Contact resistance (Initial)
1 Form C 2, 1 Form C
Contact
Rating
N.O.: Typ 7m, N.C.: Typ 10m (By voltage drop 6V DC 1A)
Ag alloy (Cadmium free)
Contact material
Nominal switching capacity (resistive load)
N.O.: 20 A 14V DC, N.C.: 10 A 14V DC
N.O.: 25 A for 1 hour, 35 A for 2 minutes at 20C 68F
20 A for 1 hour, 30 A for 2 minutes at 85C 185F
Max. carrying current (14V DC)*3
Nominal operating power
800 mW
Min. switching capacity (resistive load)*1
1 A 14V DC
Insulation resistance (Initial)
Min. 100 M (at 500V DC, Measurement at same location as “Breakdown voltage” section.)
500 Vrms for 1 min. (Detection current: 10mA)
Between open contacts
Breakdown voltage
(Initial)
Electrical
Between contacts and coil
500 Vrms for 1 min. (Detection current: 10mA)
characteristics
Operate time (at nominal voltage)
Release time (at nominal voltage)
Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10s)
Functional
Shock resistance
Destructive
Mechanical
characteristics
Functional
10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Vibration resistance
Destructive
Mechanical
Min. 107 (at 120 cpm)
<Resistive load>
Min. 105 (at nominal switching capacity, operating frequency: 1s ON, 9s OFF)
<Motor load>
N.O. side: Min. 2 105 (at Inrush 25A, Steady 5A 14 V DC),
Min. 105 (at 25A 14 V DC motor lock condition)
N.C. side: Min. 2 105 (at brake current 20A 14 V DC) (operating frequency: 0.5s ON, 9.5s
OFF)
Expected life
Conditions
Electrical
Ambient temperature: –40C to +85C –40F to +185F,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and storage*2
Max. operating speed
6 cpm (at nominal switching capacity)
Mass
Twin type: approx. 8 g .28 oz, 1 Form C type: approx. 4 g .14 oz
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
If the relay is used continuously for long periods of time with coils on both sides in an energized condition, breakdown might occur due to abnormal heating depending on
the carrying condition. Therefore, please inquire when using with a circuit that causes an energized condition on both sides simultaneously.
REFERENCE DATA
1-(1). Coil temperature rise (at room
temperature)
1-(2). Coil temperature rise (at 85C 185F)
2. Max. switching capability (Resistive load,
initial)
Sample: ACT212, 3pcs.
Contact carrying current: 0A, 10A, 20A
Ambient temperature: 85C 185F
Sample: ACT212, 3pcs.
Contact carrying current: 0A, 10A, 20A
Ambient temperature: Room temperature
(when coil powered on one side)
140
(when coil powered on one side)
140
(N.O. side: room temperature)
60
20A
120
100
80
120
50
40
20A
10A
0A
100
10A
80
0A
30
20
10
0
60
40
20
0
60
40
20
0
12
14
16
12
14
16
0
10
20
30
40
50
Coil applied voltage, V
Coil applied voltage, V
Switching current, A
ds_61205_en_ct: 010113J
2
CT (ACT)
5. Distribution of operate and release time
Sample: ACT212, 40pcs.
3. Ambient temperature and operating voltage
range
4. Distribution of pick-up and drop-out voltage
Sample: ACT212, 40pcs.
* Without diode
35
40
35
50
Operate time
Pick-up voltage
Release time
20
Drop-out voltage
40
30
25
25
20
15
10
5
30
20
20
Operating voltage range
15
10
5
10
Pick-up voltage (Cold start)
0
01.0
0 0
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
1
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5
Voltage, V
−40 −20
0
20 40 60 8085 100 120
Operate and release time, ms
Ambient temperature, °C
6-(1). Electrical life test (Motor free)
Change of pick-up and drop-out voltage
Change of contact resistance
Sample: ACT212, 3pcs.
Load: Inrush 25A, steady 5A
Brake current: 13A 14V DC,
Power window motor actual load (free condition)
Operating frequency: ON 0.5s, OFF 9.5s
Ambient temperature: Room temperature
Circuit:
50
40
30
20
10
Contact welding: 0 time
Miscontact: 0 time
8
Pick-up voltage
Sample
Max.
X
Min.
6
4
Drop-out voltage
Max.
X
Min.
10
2
0
Max.
X
M
Min.
0
0
10
20
0
10
20
No. of operations, × 104
No. of operations, × 104
Load current waveform
Inrush current: 25A, Steady current: 6A
Brake current: 13A
10A
100ms
ds_61205_en_ct: 010113J
3
CT (ACT)
6-(2). Electrical life test (Motor lock)
Change of pick-up and drop-out voltage
Change of contact resistance
Sample: ACT212, 3pcs.
Load: 25A 14V DC
50
40
30
20
10
10
Power window motor actual load (lock condition)
Switching frequency: ON 0.5s, OFF 9.5s
Ambient temperature: Room temperature
Circuit:
Contact welding: 0 time
Miscontact: 0 time
8
Sample
Pick-up voltage
6
Max.
X
Min.
4
Drop-out voltage
Max.
X
Min.
Max.
X
Min.
2
0
M
0
0
5
10
0
5
10
No. of operations, × 104
No. of operations, × 104
Load current waveform
5A
100ms
6-(3). Electrical life test (Motor lock)
Change of pick-up and drop-out voltage
Change of contact resistance
Sample: ACT212, 3pcs.
Load: 20A 14V DC,
10
9
50
40
30
20
10
0
door lock motor actual load (Lock condition)
Switching frequency: ON 0.3s, OFF 19.7s
Ambient temperature: Room temperature
8
Circuit:
Sample
7
6
5
4
Pick-up voltage
Drop-out voltage
Max.
X
Min.
Side1
M
M
M
M
M M
3
2
Max.
X
Min.
Side2
Max.
1
0
X
Min.
0
5
10
0
5
10
No. of operations, × 104
No. of operations, × 104
Relay 1
Relay 2
0.3s
9.7s
0.3s
9.7s
20s (1 cycle)
Load current waveform
5A
100ms
ds_61205_en_ct: 010113J
4
CT (ACT)
DIMENSIONS (mm inch)
Download
C
A
D
D
a
t
a
from our Web site.
1. Twin type (8 terminals)
External dimensions
PC board pattern (Bottom view)
CAD Data
17.4
.685
9.5
.374
6
14
.551
.236
4.3
.169
2.5
3
13.5
.531
0.4
.098
.118
6.8
.268
4.3
.169
Max. 1.0
.039
3.15
.124
.016
+0.1
0
15
.591
4×1.1 dia.
4×.043+00.04 dia.
3.5
.138
+0.1
0
4×1.4 dia.
*A
4×.055+00.04 dia.
0.4
.016
1
.039
1
.039
0.8
.031
0.3
.012
0.4 0.4
.016 .016
Tolerance: 0.1 .004
Pre-soldering
1.25
.049
9.5
.374
6
.236
Schematic (Bottom view)
1
.039
4.3
.169
COIL
2.5
.098
COM
NC
3
6.8
.268
.118
3.15
.124
4.3
.169
NO
Dimension:
Max. 1mm .039 inch:
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
Tolerance
0.1 .004
COIL
COM
15
.591
1.45
.057
* Dimensions (thickness and width) of terminal is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
2. Twin type (10 terminals)
External dimensions
PC board pattern (Bottom view)
CAD Data
17.4
.685
14
.551
9.5
.374
6
.236
4.3
3.15
.124
.169
2.5
.098
13.5
.531
0.4
.016
0.65
.026
3.15
.124
6.8
.268
Max. 1.0
.039
4.3
.169
+0.1
0
4×1.1 dia.
4×.043+0.04
dia.
0
3.5
.138
15
.591
0.65
.026
*A
+0.1
0
1
.039
6×1.4 dia.
6×.055+0.04
dia.
0
0.4
.016
1
.039
0.4 0.4
0.8
0.3
.012
.016 .016
.031
Tolerance: 0.1 .004
9.5
1.25
.049
Pre-soldering
.374
6
.236
Schematic (Bottom view)
4.3
3.15
.124
NO
.169
COIL
2.5
.098
NC
0.65
.026
3.15
.124
COM
6.8
.268
Dimension:
Max. 1mm .039 inch:
Tolerance
0.1 .004
4.3
.169
NO
COIL
1.45
.057
NC
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
COM
0.65
.026
15
.591
1
.039
* Dimensions (thickness and width) of terminal is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
ds_61205_en_ct: 010113J
5
CT (ACT)
3. Slim 1c type
External dimensions
PC board pattern (Bottom view)
CAD Data
17.4
.685
7.2
.283
3×1.4 dia.
3×.055 dia.
9.5
.374
6
.236
4.3
.169
3.15
.124
13.5
.531
+0.1
0
2×1.1 dia.
0.4
.016
Max. 1.0
.039
0.65
.026
2×.043+00.04 dia.
15
.591
3.5
.138
Tolerance: 0.1 .004
*A
0.4
0.8
.031
1
1
.016
.039
Schematic (Bottom view)
0.4
0.4
0.3
.012
.039
.016 .016
9.5
.374
1.25
.049
Pre-soldering
NO
6
COIL
.236
1
.039
NC
COM
Dimension:
Max. 1mm .039 inch:
Tolerance
0.1 .004
4.3
.169
3.15
.124
1 to 3mm .039 to .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
1.45
.057
0.65
.006
15
.591
* Dimensions (thickness and width) of terminal is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
EXAMPLE OF CIRCUIT
Forward/reverse control circuits of DC motor for power windows
NO
NC
NO
NC
COM
COM
12 V DC
M
SW A
SW B
M
: Power window motor
For Cautions for Use, see Relay Technical Information.
ds_61205_en_ct: 010113J
6
相关型号:
ACT1210-101-2P-TL00
Data Line Filter, 2 Function(s), 80V, 0.15A, ROHS COMPLIANT, EIA STD PACKAGE SIZE 1210, 4 PIN
TDK
ACT1210-110-2P-TL00
Data Line Filter, 2 Function(s), 80V, 0.3A, ROHS COMPLIANT, EIA STD PACKAGE SIZE 1210, 4 PIN
TDK
ACT1210-510-2P-TL00
Data Line Filter, 2 Function(s), 80V, 0.2A, ROHS COMPLIANT, EIA STD PACKAGE SIZE 1210, 4 PIN
TDK
©2020 ICPDF网 联系我们和版权申明