AHN211Y2N [PANASONIC]
Relay for control panel of 1c 10A, 2c 5A and 1a 16A; 继电器1C 10A的控制面板, 2C 5A和1A 16A型号: | AHN211Y2N |
厂家: | PANASONIC |
描述: | Relay for control panel of 1c 10A, 2c 5A and 1a 16A |
文件: | 总6页 (文件大小:136K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VDE
Relay for control panel of
1c 10A, 2c 5A and 1a 16A
HN RELAYS (AHN)
FEATURES
1. Slim and compact size
20% smaller (width and height) than
existing model* (with the condition of
screw terminal socket for DIN rail)
*Compared with our HC/HJ relay.
2. High-capacity
5. Full lineup
We added a TM type that can be built into
devices.
TYPICAL APPLICATIONS
Max. switching current:
Control panels
16 A (for 1 Form C type at AC load)
Highly reliable contact (for 2 Form C
type).
Power supply units
Molding machines
Machine tools
3. Environmentally friendly
Cadmium-free contacts and lead-free
solder are used.
Welding equipment
Agricultural equipment
Office equipment
4. Slim screw terminal socket and PC
board terminal socket
Utilizes relay-securing hook for easy
Vending machines
Communications equipment
Amusement machines, etc.
relay removal.
RoHS compliant
One-touch relay removal possible.
Terminal sockets with finger protect
function available.
ORDERING INFORMATION
AHN
HN relays
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 1 Form A (TM type only)
Terminal arrangement
1: AC plug-in type
2: DC plug-in type
5: AC TM type
6: DC TM type
Type classification
0: Standard
1: With LED indication
2: With diode
3: With diode and LED indication
Nominal coil voltage
05: 5 V, 06: 6 V, 12: 12 V, 24: 24 V, 48: 48 V
X0: 100/110 V AC, 100 V DC
X1: 110/120 V AC, 110 V DC
Y0: 200/220 V AC
Y2: 220/240 V AC
Type
N: New 2 Form C type
Nil: 1 Form C type, 1 Form A type
Note: Certified by UL/C-UL and VDE
(Please consult us for VDE approved TM type.)
ASCTB5E 201212-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
HN (AHN)
TYPES
1. Plug-in type
2. Plug-in type (with LED indication)
1 Form C
Part No.
2 Form C
1 Form C
2 Form C
Nominal coil voltage
Nominal coil voltage
Part No.
Part No.
Part No.
5V DC
6V DC
AHN12005
AHN12006
AHN12012
AHN12024
AHN12048
AHN120X0
AHN120X1
AHN11012
AHN11024
AHN110X0
AHN110X1
AHN110Y0
AHN110Y2
AHN22005N
AHN22006N
AHN22012N
AHN22024N
AHN22048N
AHN220X0N
AHN220X1N
AHN21012N
AHN21024N
AHN210X0N
AHN210X1N
AHN210Y0N
AHN210Y2N
5V DC
6V DC
AHN12105
AHN12106
AHN12112
AHN12124
AHN12148
AHN121X0
AHN121X1
AHN11112
AHN11124
AHN111X0
AHN111X1
AHN111Y0
AHN111Y2
AHN22105N
AHN22106N
AHN22112N
AHN22124N
AHN22148N
AHN221X0N
AHN221X1N
AHN21112N
AHN21124N
AHN211X0N
AHN211X1N
AHN211Y0N
AHN211Y2N
12V DC
12V DC
24V DC
24V DC
48V DC
48V DC
100V DC
110V DC
12V AC
100V DC
110V DC
12V AC
24V AC
24V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
3. Plug-in type (with diode)
4. Plug-in type (with diode and LED indication)
1 Form C
2 Form C
Part No.
1 Form C
2 Form C
Nominal coil voltage
Nominal coil voltage
Part No.
Part No.
Part No.
5V DC
6V DC
AHN12205
AHN12206
AHN12212
AHN12224
AHN12248
AHN122X0
AHN122X1
AHN22205N
AHN22206N
AHN22212N
AHN22224N
AHN22248N
AHN222X0N
AHN222X1N
5V DC
6V DC
AHN12305
AHN12306
AHN12312
AHN12324
AHN12348
AHN123X0
AHN123X1
AHN22305N
AHN22306N
AHN22312N
AHN22324N
AHN22348N
AHN223X0N
AHN223X1N
12V DC
24V DC
48V DC
100V DC
110V DC
12V DC
24V DC
48V DC
100V DC
110V DC
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
5.TM type
1 Form A
Nominal coil voltage
Part No.
5V DC
6V DC
AHN36005
AHN36006
AHN36012
AHN36024
AHN36048
AHN360X0
AHN360X1
AHN35012
AHN35024
AHN350X0
AHN350X1
AHN350Y0
AHN350Y2
12V DC
24V DC
48V DC
100V DC
110V DC
12V AC
24V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
* For sockets and terminal sockets, see page 50.
ASCTB5E 201212-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
HN (AHN)
RATING
1. Coil data
1) DC coils
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal coil current
[ 20%]
Coil resistance
(at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
5V DC
6V DC
106.4mA
88.2mA
44.4mA
22.0mA
11.0mA
5.3mA
47Ω [ 10%]
68Ω [ 10%]
270Ω [ 10%]
1,090Ω [ 10%]
4,350Ω [ 10%]
18,870Ω [ 10%]
22,830Ω [ 10%]
12V DC
24V DC
48V DC
100V DC
110V DC
70%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
170%V of
nominal voltage
0.53W
4.8mA
2) AC coils (50/60Hz)
Nominal coil current [ 20%]
Nominal operating power
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
50Hz
93mA
60Hz
75mA
50Hz
60Hz
12V AC
24V AC
46.5mA
37.5mA
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
100/110V AC
110/120V AC
200/220V AC
220/240V AC
11.0/13.0mA
10.0/11.8mA
5.5/6.5mA
5.0/5.9mA
9.0/10.6mA
8.2/9.7mA
4.5/5.3mA
4.1/4.8mA
Approx.
1.1 to 1.4 V A
Approx.
0.9 to 1.2 V A
140%V of
nominal voltage
2. Specifications (Plug-in Standard type and TM type)
Characteristics
Item
Specifications
2 Form C
Arrangement
1 Form C
1 Form A (TM type)
Max. 100 mΩ
(By voltage drop 6 V DC 1A)
Max. 50 mΩ
(By voltage drop 6 V DC 1A)
Max. 100 mΩ
(By voltage drop 6 V DC 1A)
Contact
Contact resistance (Initial)
Contact material
AgSnO2 type
AgNi type
AgSnO2 type
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
10A 250V AC, 10A 30V DC
4,000VA, 300W
5A 250V AC, 5A 30V DC
1,250VA, 150W
16A 250V AC, 16A 30V DC
4,000VA, 480W
250V AC, 30V DC
Rating
16A (at AC load),
10A (at DC load)
Max. switching current
5A
16A
Nominal operating power
0.53W, 0.9VA
100mA 5V DC
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Between open contacts
1mA 1V DC
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
Breakdown voltage
Between contact sets
(Initial)
3,000 Vrms for 1min.
(Detection current: 10mA.)
—
—
Electrical
characteristics
Between contact and coil
Temperature rise (coil) (at 70°C 158°F)
Operate time (at 20°C 68°F)*2
5,000 Vrms for 1min. (Detection current: 10mA.)
Max. 60°C 140°F (By resistive method, nominal coil voltage)
Max. 15ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 5ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without
diode)/Max. 20ms (with diode)
Release time (at 20°C 68°F)*2
Functional
Shock resistance
Min. 100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
Mechanical
AC: Min. 107; DC: Min. 2×107 (at 300 times/min.)
Min. 105 (at 20 times/min.)
Expected life
Electrical (at nominal switching capacity)
Min. 105 (at 10 times/min.)
Conditions for operation, transport and storage*3
(Not freezing and condensing at low temperature)
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
10 times/min.
(at nominal switching capacity)
Max. Operating speed
20 times/min. (at nominal switching capacity)
Approx. 19 g .67 oz Approx. 17 g .60 oz
Approx. 19 g .67 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB5E 201212-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
HN (AHN)
REFERENCE DATA
1-(1). Max. switching capacity
(1 Form C and 1 Form A)
1-(2). Max. switching capacity (2 Form C)
2-(1). Coil temperature rise (1 Form C/AC and
1 Form A/AC types)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
120
10
5
100
50
100
80
30
1 Form A type DC resistive load
16A
0A
20
16
1 Form A and
10
5
1 Form C types
AC resistive load
AC resistive load
1
1 Form C type
DC resistive load
60
40
20
0.5
0.4
0.3
0.2
1
DC resistive load
0.5
0
80 90 100 110 120 130 140
10
20 30 50
100
250
10
20 30 50 100
Contact voltage, V
250
Contact voltage, V
Coil applied voltage, %V
2-(2). Coil temperature rise (1 Form C/DC and
1 Form A/DC types)
Measured portion: Inside the coil
2-(3). Coil temperature rise (2 Form C/AC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
2-(4). Coil temperature rise (2 Form C/DC type)
Measured portion: Inside the coil
Ambient temperature: 70°C 158°F
Ambient temperature: 70°C 158°F
70
60
120
70
60
50
100
80
5A
0A
16A
50
40
5A
0A
40
30
0A
60
40
20
30
20
10
20
10
0
0
0
80 90 100 110 120 130 140
80 90 100 110 120 130 140
80 90 100 110 120 130 140
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
1. Plug-in type 1 Form C
External dimensions
Schematic (Bottom view)
Standard type
CAD Data
Max. 29
Max. 1.142
Max. 13
Max. .512
1
5
2
4
3
Max. 29
Max. 1.142
With LED AC type
With LED DC type
1
1
5.3
.209
5
1
5
2
4
3
5
2
4
3
4.75
.187
0.5
.020
With Diode type
With Diode and LED type
4.7
.185
0.5
.020
1
7.5
.295
2
4
3
5
2
4
3
5.2 5.2
.205 .205
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
17.5
.689
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
ASCTB5E 201212-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
HN (AHN)
2. Plug-in type 2 Form C
External dimensions
Schematic (Bottom view)
Standard type
CAD Data
Max. 29
Max. 1.142
Max. 13
Max. .512
1
2
3
4
8
7
6
5
Max. 28
Max. 1.102
With LED AC type
With LED DC type
1
2
3
4
1
2
3
4
8
7
6
5
8
7
6
5
6
.236
With Diode type
With Diode and LED type
2.6
.102
0.5
.020
2.6
.102
0.5
.020
1
2
3
4
1
2
3
4
8
7
6
5
8
7
6
5
8.9
.350
7.5
.295
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
Tolerance
0.1 .004
5
5
.197 .197
19.4
.764
3.TM type 1 Form A
External dimensions
Schematic
CAD Data
0.5
.020
1
4.75
.187
#187 tab terminal
0.5
.020
4.75
.187
4
3
5
8.5
.335
Mounting hole dimensions
2-M3 or 2-3.5 dia.
2-.118 or 2-.138 dia.
Max. 30
Max. 1.181
38
1.496
2.5
.098
Max. 13
Max. .512
Max. 45
Max. 1.772
Max. 29
Max. 1.142
3.7
.146
7.5
.295
Notes: 1. When mounting the TM type, since the
cover is made from polycarbonate, please
use a washer in order to prevent damage,
deformation, and loosening.
5.2
.205
17.5
.389
2. Suitable tightening torque is 0.3 to 0.5 N·m.
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch:
0.3 .012
SAFETY STANDARDS
File No.
Certification authority: UL/C-UL
10A 277V AC, 10A 30V DC
File No.
Certification authority: VDE
1 Form C
E43149*
E43149*
E43149*
40012003 10A 250V AC (cosφ=1.0), 10A 30V DC (0ms)
40012003 5A 250V AC (cosφ=1.0), 5A 30V DC (0ms)
2 Form C
5A 277V AC, 5A 30V DC
1 Form A (TM type)
16A 277V AC, 16A 30V DC, TV-5
—
**
* CSA standard: Certified by C-UL
** Please consult us.
ASCTB5E 201212-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
HN (AHN)
NOTES
1. Coil applied voltage
5. Conditions for operation, transport
and storage
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
7. Diode type
To ensure proper operation, the voltage
applied to both terminals of the coil
should be 5% (at 20°C 68°F) the rated
operating voltage of the coil.
Also, be aware that the pick-up and drop-
out voltages will fluctuate depending on
the ambient temperature and operating
conditions.
Since the diode inside the relay coil are
designed to absorb the counter emf, the
element may be damaged if a large
surge, etc., is applied to the diode.
If there is the possibility of a large surge
voltage from the outside, please
implement measures to absorb it.
8. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
–40 to +70°C – 40 to +158°F
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
Temperature and humidity range for
usage, transport, and storage
2. LED indications
The light of the light emitting diode is
what displays operation. If voltage
remains after relay dropout, the LED
might illuminate briefly.
3. Switching lifetime
Humidity, %R.H.
The switching lifetime is defined under
the standard test condition specified in
the JIS C 5442(*2) standard (temperature
15 to 35°C 59 to 95°F, humidity 25 to
75% R.H.). Check this with the real
device as it is affected by coil driving
circuit, load type, activation frequency,
activation phase,ambient conditions and
other factors.
9. Installation
If you will be installing adjacent to other
relays, please keep a distance of at least
5 mm from the relay.
85
Tolerance range
(Avoid freezing (Avoid
when used at
temperatures
lower than
condensation
when used at
temperatures
higher than
0°C 32°F)
0°C 32°F)
5
–40
–40
0
70
+158
+32
Temperature, °C °F
Also, be especially careful of loads such
as those listed below.
1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
2) High-frequency load-operating
When high-frequency opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO3 is formed. This
can corrode metal materials.
(3) Atmospheric pressure: 86 to 106 kPa
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0°C 32°F. This
causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature, low humidity
environments
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
4. Direct mount type (TM type)
If the current to the connection terminal
will exceed 10 A, we recommend
connecting with solder. If you are going to
use a tab terminal when the current will
exceed 10 A, make sure to verify the
temperature rise on the receptacle side
under actual conditions before using.
Please be careful, because excessive
stress on the TM terminal can cause
fluctuations in characteristics and
damage.
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
6. Diode characteristics
1) Reverse breakdown voltage:
Min. 1,000V (with diode type)
Min. 400V (with diode and LED indication
type)
ASCTB5E 201212-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
相关型号:
AHN22005
Power/Signal Relay, DPDT, Momentary, 0.106A (Coil), 5VDC (Coil), 530mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
AHN22006
Power/Signal Relay, DPDT, Momentary, 0.088A (Coil), 6VDC (Coil), 530mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
AHN22012
Power/Signal Relay, DPDT, Momentary, 0.044A (Coil), 12VDC (Coil), 530mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
AHN22024
Power/Signal Relay, DPDT, Momentary, 0.022A (Coil), 24VDC (Coil), 530mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
AHN22048
Power/Signal Relay, DPDT, Momentary, 0.011A (Coil), 48VDC (Coil), 530mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明