AJ8W122WF [PANASONIC]

16 A Type Power Rocker Switches with a 3 mm Contact gap Secured;
AJ8W122WF
型号: AJ8W122WF
厂家: PANASONIC    PANASONIC
描述:

16 A Type Power Rocker Switches with a 3 mm Contact gap Secured

文件: 总10页 (文件大小:451K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
16 A Type Power Rocker  
Switches with a 3 mm  
Contact gap Secured  
AJ8 (J8)  
SWITCHES  
FEATURES  
• Power rocker switches for safety requirements.  
• High inrush current resistance is ideal for Power switch of  
office automation equipment.  
• A broad product line (TV-8 rating type added to lineup)  
Standard actuator  
Wide actuator  
ORDERING INFORMATION  
AJ 8  
F
Actuator indication  
0: No indication  
Number of poles and Operation  
1: 1-pole, single throw (ON-OFF)  
2: 2-pole, single throw (ON-OFF)  
Flange color  
F: Cadmium-free product  
Nil: Black (standard color)  
(Custom ordered color:  
W: White, H: Light gray) Note 1)  
1:  
2:  
indication (Indication on top)  
indication (Indication on top)  
Actuator  
Terminal shape  
Actuator color  
Insulation guard  
Nil: Standard actuator  
W: Wide actuator  
0: .250 Quick-connect terminal  
1: Soldering terminal  
2: PC board terminal  
W: White B: Black R: Red  
Nil: Short guard type  
T: Long guard type (.250 Quick-connect terminal and  
soldering terminal of standard actuator only)  
3: PC board right angle terminal (for standard actuator only)  
4: PC board left angle terminal (for standard actuator only)  
Notes: 1. Please consult us for details concerning different flange colors.  
2. “ ” is engraved on all flanges.  
3. The color of indication on the actuator:  
• White actuator: black  
• Others: white  
4. They come with a stamp indicating safety standards.  
TV rating type  
AJ 8 2  
B TV F  
Number of poles and Operation  
2: 2-pole, single throw (ON-OFF) 0: .250 Quick-connect  
Terminal shape  
Actuator indication  
0: No indication  
Actuator color  
B: Black  
Rating  
TV: TV rating  
F: Cadmium-free product  
terminal  
1: Soldering terminal  
2:  
indication  
ビパヒペ  
AECTB4E ビパヒペパペ  
ビパヒペハパペ  
ー 1 ー  
AJ8 (J8) Switches  
PRODUCT TYPES  
Standard actuator type  
1) Without indication on actuators  
Part No.  
Without indication  
AJ8100F  
AJ8200F  
AJ8110F  
AJ8210F  
AJ8120F  
AJ8220F  
AJ8130F  
AJ8230F  
AJ8140F  
AJ8240F  
Terminal shape  
.250 Quick-connect terminal  
Soldering terminal  
Poles  
Operating types  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
PC board terminal  
ON-OFF  
PC board right angle terminal  
PC board left angle terminal  
(Standard flange color is black.)  
Notes: 1. A letter indicating the actuator color is entered in place of asterisk. (W: White, B: Black, R: Red)  
For other flange colors type, black is the standard. For requests of other flange color, please refer to ORDERING INFORMATION.  
2. Long guard type is available for .250 Quick-connect terminal and soldering terminal type. When ordering, please add a “T” before the “F” at the end of the part  
number.  
3. The color of indication on the actuator:  
• For white actuator: black  
• For others: white  
4. They come with a stamp indicating safety standards.  
5. Note that the position of the I mark on the flange is used as a reference for left angle and right angle terminals as shown in the diagram below.  
I mark  
I mark  
Right angle terminal  
Left angle terminal  
2) With indication on actuators  
Part No.  
Terminal shape  
Poles  
Operating types  
With  
indication  
With  
indication  
AJ8102F  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
AJ8101F  
.250 Quick-connect terminal  
Soldering terminal  
AJ8201F  
AJ8111F  
AJ8211F  
AJ8121F  
AJ8221F  
AJ8131F  
AJ8231F  
AJ8141F  
AJ8241F  
AJ8202F  
AJ8112F  
AJ8212F  
AJ8122F  
AJ8222F  
AJ8132F  
AJ8232F  
AJ8142F  
AJ8242F  
PC board terminal  
ON-OFF  
PC board right angle terminal  
PC board left angle terminal  
(Standard flange color is black.)  
Notes: 1. A letter indicating the actuator color is entered in place of asterisk. (W: White, B: Black, R: Red)  
For other flange colors type, black is the standard. For requests of other flange color, please refer to ORDERING INFORMATION.  
2. Long guard type is available for .250 Quick-connect terminal and soldering terminal type. When ordering, please add a “T” before the “F” at the end of the part  
number.  
3. The color of indication on the actuator:  
• For white actuator: black  
• For others: white  
4. They come with a stamp indicating safety standards.  
5. Note that the position of the I mark on the flange is used as a reference for left angle and right angle terminals as shown in the diagram below.  
I mark  
I mark  
Right angle terminal  
Left angle terminal  
ビパヒペ  
AECTB4E ビパヒペパペ  
ー 2 ー  
AJ8 (J8) Switches  
Wide actuator type  
1) Without indication on actuators  
Part No.  
Terminal shape  
.250 Quick-connect terminal  
Soldering terminal  
Poles  
Operating types  
ON-OFF  
Without indication  
AJ8W100F  
AJ8W200F  
AJ8W110F  
AJ8W210F  
AJ8W120F  
AJ8W220F  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
PC board terminal  
2) With indication on actuators  
Part No.  
Terminal shape  
Poles  
Operating types  
ON-OFF  
With  
indication  
With  
indication  
1-pole  
2-pole  
1-pole  
2-pole  
1-pole  
2-pole  
AJ8W101F  
AJ8W102F  
.250 Quick-connect terminal  
Soldering terminal  
AJ8W201F  
AJ8W111F  
AJ8W211F  
AJ8W121F  
AJ8W221F  
AJ8W202F  
AJ8W112F  
AJ8W212F  
AJ8W122F  
AJ8W222F  
PC board terminal  
(Standard flange color is black.)  
Notes: 1. A letter indicating the actuator color is entered in place of asterisk. (W: White, B: Black, R: Red)  
For other flange colors type, black is the standard. For requests of other flange color, please refer to ORDERING INFORMATION.  
2. The color of indication on the actuator:  
• For white actuator: black  
• For others: white  
3. They come with a stamp indicating safety standards.  
TV rating type  
Part No.  
Terminal shape  
.250 Quick-connect terminal  
Soldering terminal  
Poles  
Operating types  
ON-OFF  
Without indication  
AJ8200BTVF  
With  
indication  
AJ8202BTVF  
2-pole  
AJ8210BTVF  
AJ8212BTVF  
SPECIFICATIONS  
Contact rating  
Resistive load  
(Power factor = 1)  
Motor load* (EN61058-1)  
(Power factor = 0.6)  
Voltage  
Inrush load  
250V AC  
16A  
4A  
160A (8.3ms)  
Note: * The motor load is in accordance with EN61058-1. Inrush current can be switched up to the value of 6 times the indicated rating.  
TV rating  
Resistive load  
Motor load (EN61058-1)  
Capacitor load (EN61058-1)  
Lamp load (UL61058-1)  
Expected electrical life  
(at 7 cpm)  
Contact voltage  
(Power factor = 1)  
(Power factor = 0.6)  
(Inrush load)  
(TV-8)  
8/117A  
120V AC  
250V AC  
Min. 2.5 × 104  
Min. 104  
16A  
4A  
160A (8.3ms)  
Characteristics  
Item  
Specifications  
Mechanical  
Electrical (at rated load)*  
Min. 5 × 104 (at 20 cpm.)  
Min. 104 (at 7 cpm.)  
Expected life  
Insulation resistance  
Dielectric strength  
Contact resistance  
Min. 100 MΩ (at 500V DC measured by insulation resistive meter) Between terminals  
Initial, 2,000 Vrms (detection current: 10 mA) Between terminals  
Initial, Max. 100mΩ (by voltage drop at 1A, 2 to 4V DC)  
Temperature rise (at terminal section)  
Vibration resistance  
Max. 30°C at 6 × 103 ope. or less (UL61058-1), Max. 55°C from 6 × 103 ope. to 104 (EN61058-1)  
10 to 55 Hz at double amplitude of 1.5mm (Contact opening Max. 1 msec.)  
Shock resistance  
Min. 980m/s2  
Actuator strength  
40 N for 1 minute (operating direction)  
Terminal strength (.250 Quick-connect terminal)  
Ambient temperature  
100 N for 1 minute or more (Pull & push direction)  
–25°C to +85°C (no freezing and condensing)  
Flame retardancy  
UL94V-0  
Tracking resistance  
Min. 175  
1-pole  
2-pole  
2.45 1.47N  
4.5 2.5N  
AgSnO2 alloy  
Operating force  
(reference characteristics)  
Contact material  
Note: Test conditions and judgment are complying with JIS C 6571, EN61058-1 and UL61058-1.  
* Except TV rating type  
ビパヒペ  
AECTB4E ビパヒペパペ  
ー 3 ー  
AJ8 (J8) Switches  
DIMENSIONS  
(Unit: mm) General tolerance: 0.5  
Diagram of recommended  
CAD Data The CAD data of the products with a “CAD Data” mark can be downloaded from our Website.  
.250 Quick-connect terminal/Short guard type  
External dimensions  
Long guard type  
.250 Quick-connect terminal  
CAD Data  
panel mounting holes  
X
ON  
OFF  
2-pole  
1-pole  
12.9+0.1  
0
15  
12.8  
10  
30  
11  
32° 4  
7.7  
16  
ON  
OFF  
2
19.5  
4.4  
10.6  
Panel thickness  
0.75 to less than 1.25  
X
1.75 dia.  
0
28.20.1  
0.8  
6.35  
4.375  
0
15  
28  
8.75  
12.5  
1.25 or more to less than 2  
2 or more to 3  
28.40.1  
0
28.80.1  
Soldering terminal  
External dimensions  
Long guard type  
Soldering terminal  
Diagram of recommended  
panel mounting holes  
CAD Data  
X
ON  
OFF  
2-pole  
1-pole  
12.9+0.1  
0
15  
12.8  
10  
30  
32° 4  
11  
7.7  
16  
ON  
OFF  
2
19.5  
10.6  
Panel thickness  
X
0.8  
0
3.5  
2.5  
0.75 to less than 1.25  
1.25 or more to less than 2  
2 or more to 3  
28.20.1  
4.375  
8.75  
12.5  
0
15  
28  
28.40.1  
0
28.80.1  
PC board terminal  
External dimensions  
PC board pattern  
Diagram of recommended  
panel mounting holes  
CAD Data  
2-pole  
1-pole  
0.1  
15  
3
X
0.2  
0.1  
0.1  
1.2  
15  
3
0.2  
0.1  
1.2  
0.1  
12.9+0.1  
8.75  
0
0.1  
4.375  
2-pole  
1-pole  
15  
12.8  
10  
30  
32° 4  
7.7  
ON  
OFF  
2
16  
19.5  
(7.5)  
Panel thickness  
X
0
4
0.75 to less than 1.25  
28.20.1  
2
4.375  
0.8  
0
1.25 or more to less than 2  
2 or more to 3  
28.40.1  
15  
28  
8.75  
12.5  
0
28.80.1  
ビパヒペ  
AECTB4E ビパヒペパペ  
ー 4 ー  
AJ8 (J8) Switches  
PC board right angle terminal  
External dimensions  
PC board pattern  
Diagram of recommended  
panel mounting holes  
CAD Data  
2-pole  
1-pole  
0.1  
15  
3
X
0.2  
0.1  
0.1  
1.2  
8
15  
3
12.9+0.1  
0.2  
0.1  
0
0.3  
1.2  
17.5  
0.1  
0.1  
4.375  
0.3  
Terminal side  
21.0  
2-pole  
1-pole  
15  
12.8  
10  
30  
32° 4  
7.7  
16  
ON  
OFF  
2
19.5  
2
Panel thickness  
X
0
0.75 to less than 1.25  
28.20.1  
0.8  
0
8
1.25 or more to less than 2  
2 or more to 3  
28.40.1  
0
28.80.1  
28  
4
12.5  
Note: Left angle terminal type is also available.  
Wide actuator type  
External dimensions  
Diagram of recommended  
panel mounting holes  
CAD Data  
22.0+0.1  
0
X
2-pole  
1-pole  
25  
21.8  
19  
32  
32° 4  
7.7  
ON  
OFF  
2
16  
Panel thickness  
1 to less than 1.8  
1.8 or more to 2.3  
X
19.5  
0
30.00.1  
0
30.70.1  
4.4  
10.6  
Note: Dimensions for the terminals of soldering  
1.75 dia.  
0.8  
terminal type and PC board terminal type are  
the same as those of standard actuator type.  
6.35  
8.75  
21  
4.375  
15  
29.4  
Terminal circuit diagram (common)  
Terminal number marking  
Terminal circuit diagram  
Terminal shape  
1-pole  
2-pole  
PC board right angle terminal  
3)  
1)  
4)  
2)  
3)  
1)  
4)  
2)  
250 Quick-connect terminal  
Soldering terminal  
PC board terminal  
PC board left angle terminal  
ビパヒペ  
AECTB4E ビパヒペパペ  
ー 5 ー  
AJ8 (J8) Switches  
CAUTIONS FOR USE  
Switch mounting  
Avoid touching the switch with soldering  
iron.  
Resistance to chemicals  
To clean the switch unit, use a neutral  
detergent diluted with water.  
Do not use acidic or alkaline solvents as  
they may damage the switch.  
Furthermore, be careful not to get any of  
the detergent solution inside of the switch  
while cleaning it.  
Mount the switch with the hole cutting  
dimensions shown in the dimensions.  
Please contact us if you are considering  
using a panel of other than the  
recommended size and shape.  
Regarding fastening lead wires to  
terminals  
Soldering position  
When wrapping or soldering a wire  
around a terminal, do so in the shaded  
area indicated in the diagram at left.  
Contact terminal and common terminal  
1) When connecting the tab terminals,  
use a .250 Quick-connect and insert the  
terminals straight in. If they are skewed,  
the terminals will require excessive  
insertion force.  
In addition, there is some variation in the  
insertion force required for different  
receptacles from different manufacturers,  
so confirm how much force is needed  
under actual conditions.  
Do not solder wires onto tab terminals.  
2) With manual soldering: Complete the  
soldering connection work within 3  
seconds with the tip of the soldering iron  
at a temperature of 420°C or lower, and  
take care not to apply any force to the  
terminal area.  
Environment  
Refer to the diagram above, “soldering  
position,” for details on the position where  
a wire should be soldered to a terminal.  
When soldering PC board terminals,  
keep soldering time to within 5 seconds  
at 270°C soldering bath or within 3  
seconds at 350°C soldering bath.  
3) The terminals should be connected in  
such a way that they are not under  
constant stress from the connecting  
wires.  
Avoid using and storing these switches in  
a location where they will be exposed to  
corrosive gases, silicon, or high dust  
levels, all of which can have an adverse  
effect on the contacts.  
Take care not to drop the product as  
it may impair perfomance.  
4) Terminal material is copper alloy which  
may discolor due to finger’s oil or after a  
long time. But that discoloration does not  
effect actual performance.  
INTRODUCTION TO 4P CONNECTORS FOR THE AJ8 (J8) SWITCH  
(produced by Nippon Tanshi Co., Ltd)  
Suitable switches: AJ8 (J8) switch, .250 Quick-connect terminal  
(Note: Terminal guard long type switches are not suitable for this connector.)  
• Housing  
Product number: N1620-404  
Connectors for  
AJ8 (J8) switch  
• Receptacle  
Product number: 17168-2 (post-plated product for fine wires)  
17168-M2 (material plated product for fine wires)  
172131-M2 (for thick wires)  
• If you have any questions, please directly contact:  
Nippon Tanshi Co., Ltd.  
Note: This connector for AJ8 (J8) switches is not  
available from Panasonic.  
ビパヒペ  
AECTB4E ビパヒペパペ  
ー 6 ー  
TechnicalTerminology & Cautions for Use  
(Operation Switches)  
TECHNICAL TERMINOLOGY  
Rated values  
Shock resistance  
Values indicating the characteristics and performance guarantee  
standards of the switches. The rated current and rated voltage,  
for instance, assume specific conditions.  
Max. shock value where a closed contact does not open for  
longer than a specified time due to shocks during use of the  
switches.  
Electrical life  
Allowable switching frequency  
The service life when the rated load is connected to the contact  
This is the maximum switching frequency required to reach the  
and switching operations are performed.  
end of mechanical life (or electrical life).  
Mechanical life  
Temperature rise value  
The service life when operated at a preset operating frequency  
without passing electricity through the contacts.  
This is the maximum temperature rise value that heats the  
terminal portion when the rated current is flowing through the  
contacts.  
Dielectric strength  
Threshold limit value that a high voltage can be applied to a  
predetermined measuring location for one minute without  
causing damage to the insulation.  
Actuator strength  
When applying a static load for a certain period on the actuator  
in the operation direction, this is the maximum load it can  
withstand before the switch loses functionality.  
Insulation resistance  
This is the resistance value at the same place the dielectric  
Terminal strength  
strength is measured.  
When applying a static load for a certain period (in all directions  
if not stipulated) on a terminal, this is the maximum load it can  
withstand before the terminal loses functionality (except when  
the terminal is deformed).  
Contact resistance  
This indicates the electrical resistance at the contact part.  
Generally, this resistance includes the conductor resistance of  
the spring and terminal portions.  
Vibration resistance  
Vibration range where a closed contact does not open for longer  
than a specified time due to vibrations during use of the snap-  
action switches.  
AECTB38E 201811-T  
ー 7 ー  
Technical Terminology & Cautions for Use  
TYPES OF LOAD  
Resistance load  
Motor load  
Resistance load is a power factor of 1 (cosφ = 1) where the load  
is only for the resistance portion. The displayed switch rating  
indicates the current capacity when using AC current.  
Contacts may adhere due to the starting current at the start of  
motor operation which is three to eight times the steady-state  
current. Although it differs depending on the motor, since a  
current flows that is several times that of the nominal current,  
please select a switch taking into consideration the values in the  
table below. To make the motor rotate in reverse, use an ON-  
OFF-ON switch and take measures to prevent a multiplier  
current (starting current + reverse current) from flowing.  
DC load  
Differing from AC, since the direction of current is fixed for DC,  
the continuous arc time lengthens when the same voltage is  
applied.  
Motor type  
Type  
Starting current  
Incandescent lamp load  
Three-phase  
induction motor  
Approx. 5 to 8 times current listed on  
nameplate  
Squirrel-cage  
Since an inrush current of 10 to 15 times the rated current flows  
for an instant when the switch is turned on for the lamp,  
adhesion of the contacts may occur. Therefore, please take into  
consideration this transient current when selecting a switch.  
Approx. 6 times current listed on  
nameplate  
Split-phase-start  
Capacitor-start  
Repulsion-start  
Single-phase  
induction motor  
Approx. 4 to 5 times current listed on  
nameplate  
Approx. 3 times current listed on  
nameplate  
Induction load  
Since arc generation due to reverse voltage can cause contact  
failure to occur when there is an induction load (in relays,  
solenoids and buzzers, etc.), we recommend you insert a  
suitable spark quenching circuit (see figure below).  
A current that is approximately two times that of the starting  
current will flow when reverse rotation is caused during  
operation. Also, when using for a load that will cause transient  
phenomena such as when operating the motor in reverse  
rotation or switching the poles, an arc short (circuit short) may  
occur due to the time lag between poles when switching. Please  
be careful.  
Circuit example  
Notes  
Switch contact  
(1) r = more than 10 Ω  
(2) In an AC circuit,  
Example of 1-pole motor reverse rotation circuit  
r
c
R
R
R
impedance of R is to be slightly smaller  
than impedance of r and c.  
Power  
supply  
M
M
Switch contact  
Power  
supply  
Can be used for both AC and DC circuits.  
r = R  
C: 0.1 μF  
r
c
Good wiring  
Bad wiring  
Example of single-phase induction motor  
(capacitor) strong-weak switching circuit  
Switch contact  
diode  
Strong  
Strong  
Weak  
Strong  
M
For DC circuits only.  
Weak  
M
Weak  
Strong  
Power  
supply  
Switch contact  
Good wiring  
Bad wiring  
Example of three-phase motor  
ZNR  
Varistor  
Can be used for both AC and DC circuits.  
reverse rotation circuit  
Power  
supply  
M
Power  
supply  
M
Good wiring  
Bad wiring  
Capacitor load  
In the case of mercury lamps, florescent lamps and the  
capacitor loads of capacitor circuits, since an extremely large  
inrush current flows when the switch is turned on, please  
measure that transient value with the actual load and then either  
use the product keeping within the range of the rated current or  
after verifying the actual load.  
AECTB38E 201811-T  
ー 8 ー  
Technical Terminology & Cautions for Use  
CAUTIONS FOR USE  
Environment of use  
Wiring  
1) Please consult us when using under the following conditions:  
• Environments where hydrogen sulfide or other corrosive gases  
are present.  
1) When using a PC board terminal switch as soldering  
terminals, use thin lead wires and be sure to wind them on the  
terminals before soldering.  
• Environments where gasoline, thinner or other flammable,  
explosive gases are present.  
• Dusty environments (for non-seal type snap action switches).  
• Use in environments not in the prescribed temperature or  
humidity range.  
2) Cautions when soldering  
Perform soldering quickly in accordance with the specified  
conditions. Be careful not to let flux flow into the product. When  
no instruction is specified, use a soldering iron with a tip  
temperature of 350°C or lower and complete soldering within  
five seconds. Do not pull on the lead wires immediately after  
soldering. Wait some time before verifying.  
• Places with low air pressure.  
2) Unless specified the product will not be constructed to  
withstand water, oil or explosions. Please inquire if you intend to  
use the product in special applications.  
Others  
Usage, storage, and transport conditions  
1) During usage, storage, or transportation, avoid locations  
subject to direct sunlight and maintain normal temperature,  
humidity, and pressure conditions.  
2) The allowable specifications for environments suitable for  
usage, storage, and transportation are given below.  
(1) Temperature: The allowable temperature range differs for  
each switch, so refer to the switch’s individual specifications.  
(2) Humidity: 5 to 85% R.H.  
1) Failure modes of switches include short-circuiting, open-  
circuiting and temperature rises. If this switch is to be used in  
equipment where safety is a prime consideration, examine the  
possible effects of these failures on the equipment concerned,  
and ensure safety by providing protection circuits or protection  
devices. In terms of the systems involved, make provision for  
redundancy in the design and take steps to achieve safety  
design.  
2) The ambient operating temperature (and humidity) range  
quoted is the range in which the switch can be operated on a  
continuous basis: it does not mean that using the switch within  
the rating guarantees the durability performance and  
environment withstanding performance of the switch. For details  
on the performance guarantee, check the specifications of each  
product concerned.  
(3) Pressure: 86 to 106 kPa  
The humidity range varies with the temperature. Use within the  
range indicated in the graph below.  
(The allowable temperature depends on the switch.)  
Humidity, %R.H.  
3) Even if 2-pole, 3-pole or 4-pole switches are used as single-  
pole switches in order to increase contact reliability, please keep  
the maximum current no higher than the rated value.  
4) If there is the possibility of a short between poles, please use  
an in-phase circuit as shown below or provide a spare pole.  
85  
Tolerance range  
(Avoid freezing when  
used at temperatures  
lower than 0°C 32°F)  
(Avoid  
condensation when  
used at temperatures  
higher than 0°C 32°F)  
Bad example  
Load 1  
5
–40  
0
+85  
–40  
+32  
+185  
Load 2  
Temperature, °C °F  
Heteropolar circuit  
• Condensation will occur inside the switch if there is a sudden  
change in ambient temperature when used in an atmosphere of  
high temperature and high humidity. This is particularly likely to  
happen when being transported by ship, so please be careful of  
the atmosphere when shipping. Condensation is the  
phenomenon whereby steam condenses to cause water  
droplets that adhere to the switch when an atmosphere of high  
temperature and humidity rapidly changes from a high to low  
temperature or when the switch is quickly moved from a low  
humidity location to one of high temperature and humidity.  
Please be careful because condensation can cause adverse  
conditions such as deterioration of insulation, coil cutoff, and  
rust.  
Good example (1)  
Load 1  
Load 2  
In-phase circuit  
Good example (2)  
Load 1  
Spare pole  
Load 2  
• Condensation or other moisture may freeze on the switch when  
the temperatures is lower than 0°C 32°F. This causes problems  
such as sticking of movable parts or operational time lags.  
• The plastic becomes brittle if the switch is exposed to a low  
temperature, low humidity environment for long periods of time.  
• Storage for extended periods of time (including transportation  
periods) at high temperatures or high humidity levels or in  
atmospheres with organic gases or sulfide gases may cause a  
sulfide film or oxide film to form on the surfaces of the contacts  
and/or it may interfere with the functions. Check out the  
atmosphere in which the units are to be stored and transported.  
• In terms of the packing format used, make every effort to keep  
the effects of moisture, organic gases and sulfide gases to the  
absolute minimum.  
5) Be careful not to drop the product as this may cause loss of  
functionality.  
6) Do not apply an unreasonable vertical force against the  
direction of operation of the product.  
7) Use your hand to operate the actuator.  
(Operation using a tool such as a screwdriver or hammer can  
cause breakdown.)  
AECTB38E 201811-T  
ー 9 ー  
Please contact ..........  
Electromechanical Control Business Division  
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan  
industral.panasonic.com/ac/e/  
©Panasonic Corporation 2019  
Specifications are subject to change without notice.  
AECTB4E 201909  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY