ARX114H [PANASONIC]

RF Relay, SPDT, Latched, 0.044A (Coil), 4.5VDC (Coil), 200mW (Coil), 0.5A (Contact), 30VDC (Contact), 2500MHz, 20W (RF Input), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;
ARX114H
型号: ARX114H
厂家: PANASONIC    PANASONIC
描述:

RF Relay, SPDT, Latched, 0.044A (Coil), 4.5VDC (Coil), 200mW (Coil), 0.5A (Contact), 30VDC (Contact), 2500MHz, 20W (RF Input), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT

光电二极管 继电器
文件: 总4页 (文件大小:140K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
3 GHz SMALL  
MICROWAVE RELAY  
RX RELAYS (ARX)  
FEATURES  
1. Excellent high frequency  
characteristics (~2.5GHz, Impedance  
50)  
2. Small size  
• Size: 20.5(L) × 12.4(W) × 9.4(H) mm  
.807(L) × .488(W) × .370(H) inch  
3. High sensitivity  
Frequency  
to 2.5GHz  
• Nominal operating power: 200 mW  
4. Infrequent switching type is also  
available. Please inquire.  
V.S.W.R. (Max.)  
1.2  
0.2  
60  
Insertion loss (dB, Max.)  
Isolation (dB, Min.)  
0
TYPICAL APPLICATIONS  
COM-NC  
0.1  
0.2  
• Cellular phone base station  
• Cellular phone-related measurement  
devices (SP3T/SP4T switches, etc)  
• Wireless LAN  
COM-NO  
0.3  
0.4  
• Wireless Local Loop  
If you wish to use in applications with low  
level loads or with high frequency  
switching, please consult us.  
0.5  
300kHz  
1.5GHz  
Frequency  
2.5GHz3GHz  
Compliance with RoHS Directive  
ORDERING INFORMATION  
ARX  
1
RX relays  
Contact arrangement  
1: 1 Form C  
Operating function  
0: Single side stable  
1: 1 coil latching  
2: 2 coil latching  
Coil voltage (DC)  
03: 3V, 4H: 4.5V, 06: 6V, 09: 9V, 12: 12V, 24: 24V  
(H=0.5)  
TYPES  
Nominal coil  
Part No.  
voltage  
V DC  
4.5V DC  
Single side stable  
ARX1003  
1 coil latching  
ARX1103  
ARX114H  
ARX1106  
ARX1109  
ARX1112  
ARX1124  
2 coil latching  
ARX1203  
ARX124H  
ARX1206  
ARX1209  
ARX1212  
ARX1224  
3
ARX104H  
ARX1006  
6
9
V DC  
V DC  
ARX1009  
12 V DC  
24 V DC  
ARX1012  
ARX1024  
Standard packing: 50 pcs. in an inner package; 500 pcs. in an outer package  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
RX (ARX)  
RATING  
1. Coil data  
1) Single side stable  
Nominal operating  
current  
[ 10ꢀ] (at 20°C 68°F)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20°C 68°F)  
Drop-out voltage  
(at 20°C 68°F)  
Coil resistance  
[ 10ꢀ] (at 20°C 68°F)  
Nominal operating  
power  
Max. applied voltage  
(at 60°C 140°F)  
3
V DC  
66.7mA  
44.4mA  
33.3mA  
22.2mA  
16.7mA  
8.3mA  
45  
101  
4.5V DC  
75ꢀV or less of  
nominal voltage  
(Initial)  
10ꢀV or more of  
nominal voltage  
(Initial)  
6
9
V DC  
V DC  
180  
110ꢀV of nominal  
voltage  
200mW  
405  
12 V DC  
24 V DC  
720  
2,880  
2) 1 coil latching type  
Nominal operating  
current  
[ 10ꢀ] (at 20°C 68°F)  
Nominal coil  
voltage  
Set voltage  
(at 20°C 68°F)  
Reset voltage  
(at 20°C 68°F)  
Coil resistance  
[ 10ꢀ] (at 20°C 68°F)  
Nominal operating  
power  
Max. applied voltage  
(at 60°C 140°F)  
3
V DC  
66.7mA  
44.4mA  
33.3mA  
22.2mA  
16.7mA  
8.3mA  
45  
101  
4.5V DC  
75ꢀV or less of  
nominal voltage  
(Initial)  
75ꢀV or less of  
nominal voltage  
(Initial)  
6
9
V DC  
V DC  
180  
110ꢀV of nominal  
voltage  
200mW  
405  
12 V DC  
24 V DC  
720  
2,880  
3) 2 coil latching type  
Nominal operating  
current  
[ 10ꢀ] (at 20°C 68°F)  
Nominal coil  
voltage  
Set voltage  
(at 20°C 68°F)  
Reset voltage  
(at 20°C 68°F)  
Coil resistance  
[ 10ꢀ] (at 20°C 68°F)  
Nominal operating  
power  
Max. applied voltage  
(at 60°C 140°F)  
3
V DC  
133.3mA  
88.9mA  
66.7mA  
44.4mA  
33.3mA  
16.7mA  
22.5Ω  
50.6Ω  
4.5V DC  
75ꢀV or less of  
nominal voltage  
(Initial)  
75ꢀV or less of  
nominal voltage  
(Initial)  
6
9
V DC  
V DC  
90  
110ꢀV of nominal  
voltage  
400mW  
202.5Ω  
12 V DC  
24 V DC  
360  
1,440  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
Contact material  
1 Form C  
Contact  
Rating  
Stationary: Gold plating, Movable: Gold clad  
Max. 100m(By voltage drop 10V AC 10mA)  
10W (2.5GHz, Impedance 50, V.S.W.R. 1.2) 10mA 24V DC (resistive load)  
Max. 20W (at 2.5GHz, Impedance 50, V.S.W.R. 1.2, Average)  
30V DC  
Initial contact resistance, max.  
Contact rating  
Contact carrying power  
Max. switching voltage  
Max. switching current  
0.5A DC  
Single side stable  
200mW  
Nominal  
operating  
power  
1 coil latching  
2 coil latching  
200mW  
400mW  
V.S.W.R. (Return loss)  
Insertion loss  
Isolation  
Max. 1.2 (Min. 20.8dB)  
Max. 0.2dB  
High frequency  
characteristics  
(Initial) (~2.5GHz,  
Impedance 50)  
Min. 60dB  
Input power  
Max. 20W (at 40°C, V.S.W.R. 1.2, Average)  
Min. 100M(at 500V DC)  
Measurement at same location as “Initial breakdown voltage” section.  
Insulation resistance (Initial)  
Between open contacts  
500 Vrms for 1min. (Detection current: 10mA)  
1,000 Vrms for 1min. (Detection current: 10mA)  
500 Vrms for 1min. (Detection current: 10mA)  
Breakdown  
voltage  
(Initial)  
Between contact and coil  
Between contact and earth terminal  
Electrical  
characteristics  
Max. 60°C (By resistive method, nominal voltage applied to the coil: Contact carrying  
power: 20W, at 2.5GHz, Impedance 50, V.S.W.R. 1.2)  
Temperature rise (at 20°C)  
Max. 10ms (Approx. 6ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied  
to the coil, excluding contact bounce time.)  
Operate time [Set time] (at 20°C)  
Release time [Reset time] (at 20°C)  
Max. 6ms (Approx. 3ms) [Max. 10ms (Approx. 5ms)] (Nominal operating voltage applied to  
the coil, excluding contact bounce time.) (without diode)  
Functional  
Shock  
Min. 200 m/s2 {20 G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs.)  
Min. 1,000m/s2 {100 G} (Half-wave pulse of sine wave: 6ms.)  
10 to 55 Hz at double amplitude of 3mm (Detection time: 10µs.)  
10 to 55 Hz at double amplitude of 5mm  
resistance  
Destructive  
Functional  
Destructive  
Mechanical  
characteristics  
Vibration  
resistance  
Mechanical  
Electrical  
Min. 5×106 (at 180 cpm)  
Min. 105 (10W 2.5 GHz, Impedance 50, V.S.W.R. 1.2)  
Expected life  
Min. 3×105 (10mA 24V DC resistive load)  
Ambient temperature: –40°C to +70°C –40°F to +158°F  
Humidity: 5 to 85ꢀ R.H. (Not freezing and condensing at low temperature)  
Conditions  
Unit weight  
Conditions for operation, transport and storage*  
Approx. 5 g .18 oz  
Note: * The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT  
in GENERAL APPLICATION GUIDELINES.  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
RX (ARX)  
REFERENCE DATA  
1. High frequency characteristics  
Sample: ARX1012  
Measuring method: Measured with HP network analyzer (HP8753C).  
The details for the high frequency characteristics and the measurement  
procedures and conditions are listed in the RX relay test report.  
V.S.W.R. (Return loss)  
• Insertion loss  
• Isolation  
0
0
0
5.0  
COM-NC  
COM-NO  
2.0  
1.5  
10  
20  
0.1  
0.2  
20  
40  
COM-NO  
COM-NC  
1.2  
1.1  
COM-NC  
COM-NO  
30  
40  
0.3  
0.4  
60  
80  
100  
50  
0.5  
300kHz  
300kHz  
1.5GHz  
Frequency  
2.5GHz 3GHz  
1.5GHz  
Frequency  
2.5GHz3GHz  
300kHz  
1.5GHz  
Frequency  
2.5GHz 3GHz  
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac  
DIMENSIONS (mm inch)  
PC board pattern (Bottom view)  
CAD Data  
20.5  
.807  
12.4  
.488  
0.9 dia hole  
.035 dia hole  
(2 coil latching type only)  
2.54  
.100  
9.2  
.362  
7.62  
.300  
0.2  
.008  
3.0  
.118  
2.63  
.104  
2.54  
.100  
(2.04)  
(.080)  
7.62  
.300  
(2.74)  
(.108)  
0.90  
.035  
2-0.6×0.3  
Tolerance: 0.1 .004  
2-.024×.012  
General tolerance: 0.3 .012  
Single side stable  
Solder to the PC board earth.  
Schematic (Bottom view)  
1 coil latching  
7-0.40 to 0.45 dia.  
7-.016 to .018 dia.  
2 coil latching  
1
6
7
8
1
7
1
7
14 13  
12 11 10  
COM  
9
14 13 12 11 10  
9
8
14 13 12 11 10 9  
8
RESET  
SET  
NC  
COM  
NO  
RESET  
COM  
SET  
(Deenergized condition)  
(Reset condition)  
(Reset condition)  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
RX (ARX)  
NOTES  
1. Coil operating power  
6. Conditions for operation, transport  
and storage conditions  
1) Ambient temperature, humidity, and  
atmospheric pressure during usage,  
transport, and storage of the relay:  
(1) Temperature:  
4) Low temperature, low humidity  
environments  
The plastic becomes brittle if the relay is  
exposed to a low temperature, low  
humidity environment for long periods of  
time.  
Pure DC current should be applied to the  
coil. The wave form should be  
rectangular. lf it includes ripple, the ripple  
factor should be less than 5ꢀ.  
However, check it with the actual circuit  
since the characteristics may be slightly  
different. The nominal operating voltage  
should be applied to the coil for more  
than 30 ms to set/reset the latching type  
relay.  
–40 to +70°C –40 to +158°F  
(2) Humidity: 5 to 85ꢀ RH  
7. Latching relay  
In order to assure proper operating  
regardless of changes in the ambient  
usage temperature and usage conditions,  
nominal operating voltage should be  
applied to the coil for more than 30 ms to  
set/reset the latching type relay.  
(Avoid freezing and condensation.)  
The humidity range varies with the  
temperature. Use within the range  
indicated in the graph below.  
(3) Atmospheric pressure: 86 to 106 kPa  
Temperature and humidity range for  
usage, transport, and storage:  
2. Coil connection  
When connecting coils, refer to the wiring  
diagram to prevent mis-operation or  
malfunction.  
For general cautions for use, please  
refer to the “General Application  
Guidelines”.  
3. External magnetic field  
Humidity, RH  
Since RX relays are highly sensitive  
polarized relays, their characteristics will  
be affected by a strong external magnetic  
field. Avoid using the relay under that  
condition.  
85  
Tolerance range  
(Avoid freezing  
when used at  
(Avoid  
condensation  
4. Cleaning  
temperatures lower when used at  
than 0°C 32°F  
temperatures higher  
than 0°C 32°F  
For automatic cleaning, the boiling  
method is recommended. Avoid  
ultrasonic cleaning which subjects the  
relays to high frequency vibrations, which  
may cause the contacts to stick.  
lt is recommended that a fluorinated  
hydrocarbon or other alcoholic solvents  
be used.  
5. Soldering  
The manual soldering shall be performed  
under following condition.  
Max. 260°C 500°F 10s  
5
–40  
–40  
0
+32  
70  
+158  
Temperature, °C °F  
2) Condensation  
Condensation forms when there is a  
sudden change in temperature under  
high temperature and high humidity  
conditions. Condensation will cause  
deterioration of the relay insulation.  
3) Freezing  
Condensation or other moisture may  
freeze on the relay when the temperature  
is lower than 0°C 32°F. This causes  
problems such as sticking of movable  
parts or operational time lags.  
Max. 350°C 662°F 3s  
In addition, when soldering the case to  
the PC board, the plating may swell  
depending on the soldering conditions.  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  

相关型号:

ARX1203

SMALL MICRO WAVE RELAY
NAIS

ARX1206

SMALL MICRO WAVE RELAY
NAIS

ARX1209

SMALL MICRO WAVE RELAY
NAIS

ARX1212

SMALL MICRO WAVE RELAY
NAIS

ARX1212

RF Relay, SPDT, Latched, 0.033A (Coil), 12VDC (Coil), 400mW (Coil), 0.5A (Contact), 30VDC (Contact), 2500MHz, 20W (RF Input), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC

ARX1224

SMALL MICRO WAVE RELAY
NAIS

ARX1224

RF Relay, SPDT, Latched, 0.017A (Coil), 24VDC (Coil), 400mW (Coil), 0.5A (Contact), 30VDC (Contact), 2500MHz, 20W (RF Input), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC

ARX124H

SMALL MICRO WAVE RELAY
NAIS

ARX124H

RF Relay, SPDT, Latched, 0.089A (Coil), 4.5VDC (Coil), 400mW (Coil), 0.5A (Contact), 30VDC (Contact), 2500MHz, 20W (RF Input), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC

ARX1555

MIL-STD-1553/ARINC Bus Controller/RTU
ETC

ARX1555LP

MIL-STD-1553/ARINC Bus Controller/RTU
ETC

ARX18553

Transceiver
ETC