Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only;型号: | CN-73-C5 |
厂家: | PANASONIC |
描述: | Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only |
文件: | 总6页 (文件大小:618K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only
157
FX-301-F7 FX-301-F
■General terms and conditions............. F-3
Glossary of terms / General precautions....P.1549~ / P.1552~
■Selection guide ……………………… P.3~
■Korea's S-mark............................. P.1602
FIBER
SENSORS
Related Information
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Recognition
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Certified
(FX-301-F only)
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
PNP output
Light intensity
Timer
Automatic
type available monitor
STATIC
CONTROL
DEVICES
LASER
Easy operation even for beginners!
Optimum settings can be realized with simple operations
MARKERS
PLC
HUMAN MACHINE
INTERFACES
FX-301-F7
For use with leak detection or liquid detection fiber only
Sets the optimal threshold value
ENERGY
MANAGEMENT
SOLUTIONS
Incident light
intensity
(During teaching)
The FX-301-F7 (Note 1) dedicated for the leak detection fiber FD-F71
and the FX-301-F dedicated for the liquid detection fiber FT-F93 are
available. Optimal setting is possible with easy operation.
Note: The FX-301-F can be also used by setting it to leak detection mode. However, the
functions are different from the FX-301-F7 dedicated for the leak detection fiber,
so it is recommended to use the FX-301-F7 when using the leak detection fiber.
Threshold value will
be set automatically to
-20 % of the incident
light intensity during
the teaching to steadily
detect the leak. It is also
possible to change the
threshold value to -15 %
or -30 %.
FA COMPONENTS
-15 %
-20 %
-30 %
(At the time of factory shipment)
MACHINE VISION
SYSTEMS
Threshold value
UV CURING
SYSTEMS
Leak detection fiber
Liquid detection fiber
FD-F71
FT-F93
Threshold follow-up function
FX-301-F7
Selection
Guide
Incident
light
Incident light intensity is
checked at regular time
interval (10 min.), and
threshold value is reset
automatically.
Fibers
intensity
(Current value)
Fiber
Amplifiers
Threshold
value
Other Products
Dedicated amplifier for the
leak detection fiber
FX-301-F7
Dedicated amplifier for the
liquid detection fiber
FX-301-F
Time
FX-300
FX-311
*Function is set to OFF at the time of factory shipment.
Flashing function incorporated
FX-301-F7/
FX-301-F
FX-11A
When the leak detection fiber is connected (F7 mode), if
a leak is detected, you will recognize which fiber detects
the leak at a single glance because the emitter will start
flashing.
FX2
FX-CH2
FX-CH
Easy maintenance, as main and sub units are identical
Both main and sub units utilize the same amplifier body. This
feature allows for easy mounting in the side-by-side configuration.
Long life and stable operational settings due
to the newly developed emitting element
The main and sub unit
Sub cable
functions are distinguished
only by the proper use of
3-core main cable and the
1-core sub cable.
Moreover, by utilizing the same
body for both main and sub
units, inventory management
and maintenance is simplified.
The newly developed “four-chemical emitting element”
used for FX-301-F7 / FX-301-F can suppress the
secular change of the light emitting element to minimum,
allowing stable detection for long period of time.
Main cable
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
158
Easy to operate with individual / collective teaching mode
FIBER
SENSORS
Individual teaching mode (TEACH)
Collective teaching mode (ALL)
LASER
SENSORS
Optimal threshold value is set automatically on
FX-301-F7 just by setting the MODE indicator to “TEACH”
and pressing the jog switch.
Teaching is performed collectively for all the connected
amplifiers with an optical communication function when
the MODE indicator is set to “ALL”. Each amplifier will be
set with an optimal threshold value.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
The threshold value is set after selecting the liquid
detection fiber for FX-301-F.
At the same time, other setting in the master unit will
be copied to the slave unit.
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Communication direction
Collective teaching mode is possible for 16 units max.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
LEAK DETECTION FIBER (FD-F71)
STATIC
CONTROL
DEVICES
Low profile liquid detection fiber with high chemical resistance
LASER
MARKERS
Labor-saving design
•Because all you need to install is one screw, one-touch
PLC
mounting of the fiber head is possible.
•Replacement parts even for resetting after a leak are
unnecessary.
HUMAN MACHINE
INTERFACES
•Because the fiber head is simply designed, wiping off
leaks is rendered easy.
ENERGY
MANAGEMENT
SOLUTIONS
Superb explosion resistance / chemical resistance
FA COMPONENTS
SEMI S2 compliant!
Explosion resistance is enhanced by adopting the fiber
method (SEMI S2 compliant). The head unit made
of fluorocarbon polymers also has superb chemical
resistance.
MACHINE VISION
SYSTEMS
Leak detection fiber cannot be used in combination
with the FX-100/300/311/410 series.
UV CURING
SYSTEMS
Stable detection performance
The unique effect of capillarity enables reliable detection
of small leaks and viscous liquids.
Amplifier Built-in Leak Detection Sensor
High-speed detection
even a little liquid leak
Selection
Guide
Fibers
FD-F71
Fiber
EX-F70 SERIES
EX-F60 SERIES
Amplifiers
Other Products
FX-300
FX-311
P.877~
FX-301-F7/
FX-301-F
FX-11A
Capillarity effect
Fiber head
FX2
FX-CH2
FX-CH
Liquid
Leakage pan
Compact, space-saving
This slim (10 mm 0.394 in) side-mounting fiber head is
especially good for use in confined spaces.
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
159
LIQUID DETECTION FIBER (PIPE-MOUNTABLE) (FT-F93)
Stably detect the liquid inside the pipe!
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
Stable design that doesn’t permit liquid-absent or
sensor errors
MICRO
PHOTO-
•When liquid is present, its effect on the lens causes
light to focus and enter.
ELECTRIC
SENSORS
AREA
SENSORS
Liquid present
Liquid absent
SAFETY LIGHT
CURTAINS
/
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
Beam-receiving signal
Low
Beam-receiving signal
High
INDUCTIVE
PROXIMITY
SENSORS
SEMI S2 compliant!
PARTICULAR
USE
•When abnormalities such as a severed or removed
fiber or a cutoff cable occur, light does not enter and the
sensor will output the same as “liquid-absent”.
Leak detection fiber cannot be used in combination
with the FX-100/300/311/410 series.
SENSORS
SENSOR
OPTIONS
When the fiber cable is severed
SIMPLE
WIRE-SAVING
UNITS
Superior explosion resistance compatible to SEMI S2
Because there is no electric circuitry in the fiber head, it
boasts excellent explosion resistance.
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
Beam-receiving signal
Easy to use and reliable detection
Severed!
Zero
SENSORS
STATIC
CONTROL
DEVICES
Even when the shape and thickness of the pipe vary, this
fiber head uses a method where the beam axis follows
the diameter of the pipe, and so when compared to
conventional methods, the shape and thickness of the
pipe have no influence over the performance of this fiber
head.
Reliable detection not affected by bubbles or droplets
Latest optical fiber techniques have solved problems
caused by bubbles, droplets or liquid leakage that arise
in conventional pipe-mountable fiber heads.
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
ORDER GUIDE
FA
COMPONENTS
Amplifiers
Quick-connection cable is not supplied with the amplifier. Please order it separately.
MACHINE
VISION
SYSTEMS
UV
CURING
Type
Appearance
Model No.
Emitting element
Output
SYSTEMS
NPN output
PNP output
NPN output
PNP output
FX-301-F7
NPN open-collector transistor
Leak
detection
fiber only
Red LED
Selection
Guide
FX-301P-F7
FX-301-F
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
Fibers
Fiber
Amplifiers
Other
Products
Liquid
detection
fiber only
Red LED
FX-301P-F
FX-300
FX-311
FX-301-F7/
FX-301-F
Quick-connection cable is not supplied with the amplifier. Please order it separately.
Quick-connection cables
FX-11A
FX2
Main cable
Type
Model No.
Description
• CN-73-C□
FX-CH2
FX-CH
Length: 1 m 3.281 ft
CN-73-C1
CN-73-C2
CN-73-C5
CN-71-C1
CN-71-C2
CN-71-C5
0.2 mm2 3-core cabtyre cable, with
Main cable
(3-core)
Length: 2 m 6.562 ft connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Sub cable
0.2 mm2 1-core cabtyre cable, with
Sub cable
(1-core)
Length: 2 m 6.562 ft connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
• CN-71-C□
Length: 5 m 16.404 ft
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
160
ORDER GUIDE
FIBER
SENSORS
LASER
End plates are not supplied with the amplifier. Please order it separately when the amplifiers are mounted in cascade.
SENSORS
End plates
PHOTO-
ELECTRIC
SENSORS
Appearance
Model No.
Description
MICRO
PHOTO-
ELECTRIC
SENSORS
When amplifiers are mounted in cascade, or when
an amplifier moves depending on the way it is
installed on a DIN rail, these end plates clamp
amplifiers into place on both sides. Make sure to
use end plates when cascading multiple amplifiers
together.
AREA
SENSORS
MS-DIN-E
SAFETY LIGHT
CURTAINS
SAFETY
/
COMPONENTS
2 pcs. per set
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
: Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°)
and more flexible (bending radius: R4 mm R0.157 in or less) features.
Fiber heads
PARTICULAR
USE
: Refers to a fiber which possesses unbreakable bending-resistant feature (bending radius: R10 mm R0.394 in,
reciprocating bending: 180°).
Bending durability
SENSORS
SENSOR
OPTIONS
Bending Fiber cable length
Shape of fiber head
Ambient
temp.
radius
(mm)
:
Designation
Model No.
Description
Protection
Dimensions
(mm in)
SIMPLE
Free-cut
WIRE-SAVING
UNITS
SEMI S2 compliant
Liquid leak detection
−20 to
+60 °C
−4 to
WIRE-SAVING
SYSTEMS
Bending durability
W20 × H30 × D10
Leak absent: Beam received,
Leak present: Beam not received
Dedicated amplifier for the leak detection fiber :
FX-301-F7
Leak
detection
fiber
W0.787 × H1.181 × D0.394
IP67
P.68
5 m
16.405 ft
R4
FD-F71
MEASURE-
MENT
+140 °F
SENSORS
STATIC
CONTROL
DEVICES
Applicable pipe diameter:
Outer dia. ø3 to ø10 mm
SEMI S2 compliant
Bending durability
W23 × H20 × D17
ø0.118 to ø0.394 in Transparent pipe
PFA (fluorine resin) or equivalently transparent pipe,
wall thickness 0.3 to 1.0 mm 0.012 to 0.039 in
Liquid absent: Beam not received,
Liquid present: Beam received
LASER
Protective
tube R20
Fiber
−40 to
+60 °C
−40 to
MARKERS
Liquid
detection
fiber
W0.906 × H0.787 × D0.669
IP40
P.58
FT-F93
2 m
6.562 ft
PLC
R2
+140 °F
HUMAN
Dedicated amplifier for the liquid detection fiber :
FX-301-F
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
About the handling of the fiber cable length changed product
The type with fiber cable length changed is prepared as a semi-custom product with fast response.
Please contact the sales regarding the model name, standard price, and delivery.
• Applicable fiber cable length: Up to 25 m 82.021 ft, in 1 m 3.281 ft intervals.
FA
COMPONENTS
MACHINE
VISION
• Applicable protective tube length: Up to 10 m 32.808 ft, in 0.5 m 1.641 ft intervals.
SYSTEMS
UV
CURING
SYSTEMS
Accessories
FX-CT2 (Fiber cutter)
FX-AT4 (Attachment for ø1 mm ø0.039 in fiber, black)
MS-FD-F7-1 (SUS mounting bracket for FD-F71)
MS-FD-F7-2 (PVC mounting bracket for FD-F71)
Selection
Guide
Fibers
• FX-CT2
• FX-AT4
• MS-FD-F7-1
(SUS mounting bracket for FD-F71)
• MS-FD-F7-2
(PVC mounting bracket for FD-F71)
Fiber
Amplifiers
Other
Products
FX-300
FX-311
OPTIONS
FX-301-F7/
FX-301-F
FX-11A
FX2
Amplifier mounting bracket
Designation
Model No.
Description
• MS-DIN-2
FX-CH2
FX-CH
Amplifier
mounting bracket
Mounting bracket for amplifier
MS-DIN-2
FX-MB1
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplifier, as well as, prevents effect on another amplifier.
Connector seal:
Fiber sensor
amplifier
protection seal
Fiber sensor amplifier protection seal
Communication
window seal
• FX-MB1
It prevents contact of any metal, etc., with the pins of the quick-
connection cable.
Connector seal
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
161
FIBER
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from our website.
SENSORS
LASER
SENSORS
Amplifier
FX-301(P)-F7 FX-301(P)-F
PHOTO-
ELECTRIC
SENSORS
48.2
12
1.898
0.472
MICRO
PHOTO-
26.3
1.035
ELECTRIC
SENSORS
0.7
8.3
2.5
0.028
0.327
0.098
AREA
SENSORS
Operation indicator (Orange)
SAFETY LIGHT
MODE key
Jog switch
FX-301(P)-F7:
CURTAINS
/
SAFETY
Automatic follow-up function indicator
FX-301(P)-F:
Digital display (Red)
COMPONENTS
PRESSURE /
FLOW
Model indicator (Green) (Note 1)
SENSORS
3
3
INDUCTIVE
PROXIMITY
SENSORS
64.5 2.539
Communication
window
10
0.118
0.118
27.8
1.094
0.394
7
Beam-
emitting
part
0.276
PARTICULAR
USE
SENSORS
30.5
SENSOR
OPTIONS
1.201
10.5
7 0.276
Beam-
receiving
part
0.413
7 0.276
SIMPLE
WIRE-SAVING
UNITS
3
3.95
0.118 13.5
0.531
36.5
0.156
1.437
Suitable for 35 mm 1.378 in width DIN rail
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
Note: Above figure is an external dimension drawing of the FX-301(P)-F7. Shape of the indicator for FX-301(P)-F is little different.
STATIC
CONTROL
DEVICES
LASER
Main cable (Optional)
Sub cable (Optional)
CN-73-C□
CN-71-C□
MARKERS
PLC
L
L
HUMAN
MACHINE
INTERFACES
ø3.3 ø0.130 cable
10
ø3.3 ø0.130 cable
10
0.394
6
0.394
6
ENERGY
MANAGEMENT
SOLUTIONS
14
14
0.551
0.236
2.9
0.236
2.9
0.551
0.114
0.114
2.54
2.54
FA
0.100
0.100
COMPONENTS
10.5
10.5
MACHINE
VISION
0.413
0.413
SYSTEMS
2.54
7
2.54
7
UV
CURING
0.100
0.2
0.008
3
0.2
0.008
0.100
0.276
10
0.276
10
3
2.65
2.65
0.118
SYSTEMS
0.118
0.104
0.104
0.394
7.2
0.394
7.2
13.6
0.283
13.6
0.283
0.535
0.535
• Length L
Model No.
CN-73-C1
CN-73-C2
CN-73-C5
• Length L
Model No.
CN-71-C1
CN-71-C2
CN-71-C5
Selection
Guide
Length L
Length L
Fibers
1,000 39.390
2,000 78.740
5,000 196.850
1,000 39.390
2,000 78.740
5,000 196.850
Fiber
Amplifiers
Other
Products
FX-300
FX-311
Amplifier mounting bracket (Optional)
End plates (Optional)
MS-DIN-2
MS-DIN-E
FX-301-F7/
FX-301-F
21.6
2.75
0.850
0.108
FX-11A
FX2
3.2
16
5.2
0.126
0.630
0.205
M3 (length 18 mm 0.709 in) pan head screws
3
10
8.5
0.335
0.394
FX-CH2
FX-CH
60
3
2.362
0.118
0.118
15
5.6 M3 square nut
3.2
5.2
0.591
0.220
0.126
5
0.205
0.197
35
1.378
0.4
2
24.7
0.016 0.079
0.972
ø1.8
2
ø0.071 0.079
7.5
32
4
1.6
0.063
4.2 0.165
0.295
t 1
t 0.039
1.260
0.157
Suitable for 35 mm 1.378 in width DIN rail
27
2-ø3.2 ø0.126 holes
1.063
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Material: Polycarbonate
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
162
DIMENSIONS (Unit: mm in)
FIBER
The CAD data can be downloaded from our website.
SENSORS
LASER
SENSORS
FD-F71
Free-cut
FT-F93
Free-cut
PHOTO-
<with FX-AT4>
<with FX-AT4>
ELECTRIC
SENSORS
Fiber
20 0.787
2,000 78.740
1,000
5,000 196.850
3,000 118.110
30 1.181
Beam-emitting side
(Gray)
12
MICRO
2-ø1 ø0.039
2-ø1
ø0.039
39.370
Emission indicator
PHOTO-
ELECTRIC
SENSORS
0.472
7.8 0.307
Beam-emitting side
(Gray)
7.2 0.283
10
Beam-receiving side
(Black)
ø0.25 ø0.010 × 4 fiber core (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
23
0.906
AREA
Beam-receiving side
(Black)
ø0.25 ø0.010 fiber core × 4 (PMMA)
Outer sheath ø1 ø0.039 (Polyethylene)
0.394
0.787
20
6 0.236
10.3 0.406
SENSORS
Enclosure
(ABS)
5.5 0.217
SAFETY LIGHT
CURTAINS
SAFETY
/
[PFA(Fluorine resin)]
ø3.1 ø0.122 Protective tube [PFA(Fluorine resin)]
(ø3.1) (ø0.122) Protective tube
[PFA(Fluorine resin)]
6 0.236
COMPONENTS
ø3.1 ø0.122
10
0.394
PRESSURE /
FLOW
17
0.669
9 0.354
SENSORS
22 0.866
INDUCTIVE
PROXIMITY
SENSORS
SUS mounting bracket
(MS-FD-F7-1)
PARTICULAR
USE
SUS mounting bracket
mounting diagram
SENSORS
17
0.669
SENSOR
OPTIONS
6.2 0.244
10
0.394
30 1.181
10
0.3
0.012
15
0.591
SIMPLE
0.394
12.2 0.480
0.697
17.7
WIRE-SAVING
UNITS
5.5 0.217
11 0.433
FD-F71
11.5
0.453
ø4.2 ø0.165 thru-holes
Material: [PFA(Fluorine resin)]
SUS mounting bracket
WIRE-SAVING
SYSTEMS
Material: Stainless steel (SUS316)
10.3 0.406
0.3 0.012
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
PVC mounting bracket
(MS-FD-F7-2)
PVC mounting bracket
mounting diagram
LASER
12
0.472
MARKERS
30 1.181
10
25 0.394
10
0.394
5.7
0.224
PLC
0.984
10.5 0.413
15.5
0.610
FD-F71
HUMAN
4 0.157
Welding part
MACHINE
INTERFACES
11.5
0.453
PVC mounting bracket
11
0.433
Material: PVC
ENERGY
10 0.394
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Fiber
Amplifiers
Other
Products
FX-300
FX-311
FX-301-F7/
FX-301-F
FX-11A
FX2
FX-CH2
FX-CH
相关型号:
CN015P-2001-0
PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI
CN015P-2001-1
PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI
CN015P-2103-0
PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI
CN015P-2103-1
PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI
CN015P-2103-2
PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI
CN015P-2113-0
PCMCIA Connector, 24 Contact(s), 1 Row(s), Male, Right Angle, Surface Mount Terminal, Receptacle
YAMAICHI
CN015P-2203-0
PCMCIA Connector, 24 Contact(s), 1 Row(s), Male, Right Angle, Surface Mount Terminal, Receptacle
YAMAICHI
©2020 ICPDF网 联系我们和版权申明