HC1-HPL-AC100V-F [PANASONIC]
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT;型号: | HC1-HPL-AC100V-F |
厂家: | PANASONIC |
描述: | Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总18页 (文件大小:1095K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1c, 2c, 4c
To Be Discontinued
Last time buy: September 30, 2018
Relay for control panel of
1A to 10A (1c/2c/3c/4c)
HC RELAYS
FEATURES
TYPICAL APPLICATIONS
1. Standard type and Amber sealed
type
1. Factory automation equipment and
automotive devices
2. Rich lineup includes relays with
operating indication, with diode
3. Full range of types
Plug-in type, PC board type and TM
type
2. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
3. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
4. All types of household appliance
Standard type
Amber sealed type
4. Sockets and terminal sockets are
available.
With diode type
RoHS compliant
Protective construction: Dust cover type/
Sealed type
ORDERING INFORMATION
Standard type
Amber sealed type
HC
HC
Contact arrangement
1: 1 Form C
Contact arrangement
1: 1 Form C
2: 2 Form C
2: 2 Form C
3: 3 Form C
4: 4 Form C
4: 4 Form C
4D: Bifurcated contact (twin)
E: Amber sealed type
ED: Amber sealed type bifurcated contact
Terminal arrangement
(twin) (Only 4 Form C)
H:
Plug-in type
Terminal arrangement
HL: Plug-in with LED indication
HP: PC board type
HPL: PC board with LED indication
HTM: TM type
H:
L:
Plug-in type
Plug-in with LED indication
HP: PC board type
PL: PC board with LED indication
HTM: TM type
Nominal coil voltage
AC: 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC: 6, 12, 24, 48, 100 (100/110) V
Nominal coil voltage
AC: 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC: 6, 12, 24, 48, 100 (100/110) V
Contact material
Contact
Contact material
Contact
Contact
material
Contact
AgSnO2 type
AgNi type
arrangement
material
AgSnO2 type
AgNi type
1 Form C
F
F
F
arrangement
2 Form C
3 Form C
4 Form C
1 Form C
2 Form C
4 Form C
F
F
Nil
Nil
Nil
Nil
4-pole bifurcated (twin)
4-pole bifurcated (twin)
ASCTB4E 201709-T
–1–
To Be Discontinued
Last time buy: September 30, 2018
HC
With diode type (For DC)
HC
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 3 Form C
4: 4 Form C
4D: Bifurcated contact (twin)
Terminal arrangement
Nil: Plug-in type
L: Plug-in with LED indication
Nominal coil voltage
DC: 6, 12, 24, 48, 100 (100/110) V
Surge suppression
D: With diode
Contact material
Contact
material
Contact
AgSnO2 type
AgNi type
arrangement
1 Form C
F
F
F
2 Form C
3 Form C
4 Form C
Nil
Nil
4-pole bifurcated (twin)
LINEUP
Type
Contact arrangement
Remarks
Plug-in terminal type
PC board terminal type
Top mounting type
(TM type)
Without LED
With LED
Without LED
With LED
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C
1 Form C
2 Form C
4 Form C
4 Form C
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Single side stable
HC relay
Standard type
A
A
A
A
A
A
Bifurcated (Twin)
Single side stable
Bifurcated (Twin)
A
A
A
A
A
A
HC relay
Amber sealed
type
A
A
A
A
A
A
A
A
A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
DC type with
surge absorbing
diode
Single side stable
Bifurcated (Twin)
Amber sealed type
also available
A: Available
Notes: 1. HC relays with ground terminals also available.
2. HC relays with 0.9 mm wide PC board terminals also available.
HC RELAY CONTACT ARRANGEMENT
Type
Single side stable contact
4-pole bifurcated (twin) contact
HC4D
Part number
HC�
Suitable for high-capacity load switching
Standard type HC relays have high single-contact capacity;
1 Form C: 10 A
2 Form C and 3 Form C: 7 A
4 Form C: 5 A
Bifurcated (twin) contact ensures high contact reliability
Suitable for low level loads
Minimum switching capability: 100 μA 100m V DC (reference value)
Features
ASCTB4E 201709-T
–2–
To Be Discontinued
Last time buy: September 30, 2018
HC
LED INDICATION TYPE
Type
With LED indication type
Part number
HC�-HL
1
5
2
6
3
7
4
8
9
10
11
12
LED lights up when relay is operating
Inspection and detection of trouble is easy.
LEDs are green for DC types and red for
AC types.
13–
+14
Features
All types are available with LED indication.
LED
• LED colors indicate the type of relay:
red for AC type and green for DC type.
Protection diode
(Bottom view)
HC RELAY SERIES PRODUCT TYPES
Type
Amber sealed type HC relay
HC relay with diode type (for DC)
HC�-�-�V-D
Part number
HC�E
Has built-in diode to absorb surge when the coil goes to the off state (for
DC type).
Suitable for protecting relay driver circuits and for noise suppression
Relay is completely sealed with resin.
Provides high reliability in adverse surroundings.
Features
Suitable for use in dusty conditions or where organic gases are present Diode characteristics: Reverse breakdown voltage 1,000 V
Forward current 1 A
4-pole bifurcated (twin) type and Relay with LED indication are available.
TYPES
1. Standard type
1) Plug-in type
1 Form C
2 Form C
3 Form C
4 Form C
Part No.
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
HC1-H-AC6V-F
HC1-H-AC12V-F
HC1-H-AC24V-F
HC1-H-AC48V-F
HC1-H-AC100V-F
HC1-H-AC120V-F
HC1-H-AC200V-F
HC1-H-AC240V-F
HC1-H-DC6V-F
HC1-H-DC12V-F
HC1-H-DC24V-F
HC1-H-DC48V-F
HC1-H-DC100V-F
HC2-H-AC6V-F
HC2-H-AC12V-F
HC2-H-AC24V-F
HC2-H-AC48V-F
HC2-H-AC100V-F
HC2-H-AC120V-F
HC2-H-AC200V-F
HC2-H-AC240V-F
HC2-H-DC6V-F
HC2-H-DC12V-F
HC2-H-DC24V-F
HC2-H-DC48V-F
HC2-H-DC100V-F
HC3-H-AC6V-F
HC3-H-AC12V-F
HC3-H-AC24V-F
HC3-H-AC48V-F
HC3-H-AC100V-F
HC3-H-AC120V-F
HC3-H-AC200V-F
HC3-H-AC240V-F
HC3-H-DC6V-F
HC3-H-DC12V-F
HC3-H-DC24V-F
HC3-H-DC48V-F
HC3-H-DC100V-F
HC4-H-AC6V
HC4-H-AC12V
HC4-H-AC24V
HC4-H-AC48V
HC4-H-AC100V
HC4-H-AC120V
HC4-H-AC200V
HC4-H-AC240V
HC4-H-DC6V
HC4-H-DC12V
HC4-H-DC24V
HC4-H-DC48V
HC4-H-DC100V
HC4D-H-AC6V
HC4D-H-AC12V
HC4D-H-AC24V
HC4D-H-AC48V
HC4D-H-AC100V
HC4D-H-AC120V
HC4D-H-AC200V
HC4D-H-AC240V
HC4D-H-DC6V
HC4D-H-DC12V
HC4D-H-DC24V
HC4D-H-DC48V
HC4D-H-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (with LED indication)
1 Form C
2 Form C
3 Form C
4 Form C
Part No.
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
HC1-HL-AC6V-F
HC1-HL-AC12V-F
HC1-HL-AC24V-F
HC1-HL-AC100V-F
HC1-HL-AC120V-F
HC1-HL-AC200V-F
HC1-HL-AC240V-F
HC1-HL-DC6V-F
HC1-HL-DC12V-F
HC1-HL-DC24V-F
HC1-HL-DC48V-F
HC1-HL-DC100V-F
HC2-HL-AC6V-F
HC2-HL-AC12V-F
HC2-HL-AC24V-F
HC2-HL-AC100V-F
HC2-HL-AC120V-F
HC2-HL-AC200V-F
HC2-HL-AC240V-F
HC2-HL-DC6V-F
HC2-HL-DC12V-F
HC2-HL-DC24V-F
HC2-HL-DC48V-F
HC2-HL-DC100V-F
HC3-HL-AC6V-F
HC3-HL-AC12V-F
HC3-HL-AC24V-F
HC3-HL-AC100V-F
HC3-HL-AC120V-F
HC3-HL-AC200V-F
HC3-HL-AC240V-F
HC3-HL-DC6V-F
HC3-HL-DC12V-F
HC3-HL-DC24V-F
HC3-HL-DC48V-F
HC3-HL-DC100V-F
HC4-HL-AC6V
HC4-HL-AC12V
HC4-HL-AC24V
HC4-HL-AC100V
HC4-HL-AC120V
HC4-HL-AC200V
HC4-HL-AC240V
HC4-HL-DC6V
HC4-HL-DC12V
HC4-HL-DC24V
HC4-HL-DC48V
HC4-HL-DC100V
HC4D-HL-AC6V
HC4D-HL-AC12V
HC4D-HL-AC24V
HC4D-HL-AC100V
HC4D-HL-AC120V
HC4D-HL-AC200V
HC4D-HL-AC240V
HC4D-HL-DC6V
HC4D-HL-DC12V
HC4D-HL-DC24V
HC4D-HL-DC48V
HC4D-HL-DC100V
24V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
ASCTB4E 201709-T
–3–
To Be Discontinued
Last time buy: September 30, 2018
HC
3) PC board type
1 Form C
2 Form C
3 Form C
4 Form C
Part No.
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
HC1-HP-AC6V-F
HC1-HP-AC12V-F
HC1-HP-AC24V-F
HC1-HP-AC48V-F
HC1-HP-AC100V-F
HC1-HP-AC120V-F
HC1-HP-AC200V-F
HC1-HP-AC240V-F
HC1-HP-DC6V-F
HC1-HP-DC12V-F
HC1-HP-DC24V-F
HC1-HP-DC48V-F
HC1-HP-DC100V-F
HC2-HP-AC6V-F
HC2-HP-AC12V-F
HC2-HP-AC24V-F
HC2-HP-AC48V-F
HC2-HP-AC100V-F
HC2-HP-AC120V-F
HC2-HP-AC200V-F
HC2-HP-AC240V-F
HC2-HP-DC6V-F
HC2-HP-DC12V-F
HC2-HP-DC24V-F
HC2-HP-DC48V-F
HC2-HP-DC100V-F
HC3-HP-AC6V-F
HC3-HP-AC12V-F
HC3-HP-AC24V-F
HC3-HP-AC48V-F
HC3-HP-AC100V-F
HC3-HP-AC120V-F
HC3-HP-AC200V-F
HC3-HP-AC240V-F
HC3-HP-DC6V-F
HC3-HP-DC12V-F
HC3-HP-DC24V-F
HC3-HP-DC48V-F
HC3-HP-DC100V-F
HC4-HP-AC6V
HC4-HP-AC12V
HC4-HP-AC24V
HC4-HP-AC48V
HC4-HP-AC100V
HC4-HP-AC120V
HC4-HP-AC200V
HC4-HP-AC240V
HC4-HP-DC6V
HC4-HP-DC12V
HC4-HP-DC24V
HC4-HP-DC48V
HC4-HP-DC100V
HC4D-HP-AC6V
HC4D-HP-AC12V
HC4D-HP-AC24V
HC4D-HP-AC48V
HC4D-HP-AC100V
HC4D-HP-AC120V
HC4D-HP-AC200V
HC4D-HP-AC240V
HC4D-HP-DC6V
HC4D-HP-DC12V
HC4D-HP-DC24V
HC4D-HP-DC48V
HC4D-HP-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HP-AC6V-31-F.
4) PC board type (with LED indication)
1 Form C
2 Form C
3 Form C
4 Form C
Part No.
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
HC1-HPL-AC6V-F
HC1-HPL-AC12V-F
HC1-HPL-AC24V-F
HC1-HPL-AC100V-F
HC1-HPL-AC120V-F
HC1-HPL-AC200V-F
HC1-HPL-DC6V-F
HC1-HPL-DC12V-F
HC1-HPL-DC24V-F
HC1-HPL-DC48V-F
HC1-HPL-DC100V-F
HC2-HPL-AC6V-F
HC2-HPL-AC12V-F
HC2-HPL-AC24V-F
HC2-HPL-AC100V-F
HC2-HPL-AC120V-F
HC2-HPL-AC200V-F
HC2-HPL-DC6V-F
HC2-HPL-DC12V-F
HC2-HPL-DC24V-F
HC2-HPL-DC48V-F
HC2-HPL-DC100V-F
HC3-HPL-AC6V-F
HC3-HPL-AC12V-F
HC3-HPL-AC24V-F
HC3-HPL-AC100V-F
HC3-HPL-AC120V-F
HC3-HPL-AC200V-F
HC3-HPL-DC6V-F
HC3-HPL-DC12V-F
HC3-HPL-DC24V-F
HC3-HPL-DC48V-F
HC3-HPL-DC100V-F
HC4-HPL-AC6V
HC4-HPL-AC12V
HC4-HPL-AC24V
HC4-HPL-AC100V
HC4-HPL-AC120V
HC4-HPL-AC200V
HC4-HPL-DC6V
HC4-HPL-DC12V
HC4-HPL-DC24V
HC4-HPL-DC48V
HC4-HPL-DC100V
HC4D-HPL-AC6V
HC4D-HPL-AC12V
HC4D-HPL-AC24V
HC4D-HPL-AC100V
HC4D-HPL-AC120V
HC4D-HPL-AC200V
HC4D-HPL-DC6V
HC4D-HPL-DC12V
HC4D-HPL-DC24V
HC4D-HPL-DC48V
HC4D-HPL-DC100V
24V AC
100/110V AC
110/120V AC
200/220V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” before “-F” in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HPL-AC6V-31-F.
5) TM type
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
Part No.
6V AC
12V AC
HC1-HTM-AC6V-F
HC1-HTM-AC12V-F
HC1-HTM-AC24V-F
HC1-HTM-AC48V-F
HC1-HTM-AC100V-F
HC1-HTM-AC120V-F
HC1-HTM-AC200V-F
HC1-HTM-DC6V-F
HC1-HTM-DC12V-F
HC1-HTM-DC24V-F
HC1-HTM-DC48V-F
HC1-HTM-DC100V-F
HC2-HTM-AC6V-F
HC2-HTM-AC12V-F
HC2-HTM-AC24V-F
HC2-HTM-AC48V-F
HC2-HTM-AC100V-F
HC2-HTM-AC120V-F
HC2-HTM-AC200V-F
HC2-HTM-DC6V-F
HC2-HTM-DC12V-F
HC2-HTM-DC24V-F
HC2-HTM-DC48V-F
HC2-HTM-DC100V-F
HC3-HTM-AC6V-F
HC3-HTM-AC12V-F
HC3-HTM-AC24V-F
HC3-HTM-AC48V-F
HC3-HTM-AC100V-F
HC3-HTM-AC120V-F
HC3-HTM-AC200V-F
HC3-HTM-DC6V-F
HC3-HTM-DC12V-F
HC3-HTM-DC24V-F
HC3-HTM-DC48V-F
HC3-HTM-DC100V-F
HC4-HTM-AC6V
HC4-HTM-AC12V
HC4-HTM-AC24V
HC4-HTM-AC48V
HC4-HTM-AC100V
HC4-HTM-AC120V
HC4-HTM-AC200V
HC4-HTM-DC6V
HC4-HTM-DC12V
HC4-HTM-DC24V
HC4-HTM-DC48V
HC4-HTM-DC100V
HC4D-HTM-AC6V
HC4D-HTM-AC12V
HC4D-HTM-AC24V
HC4D-HTM-AC48V
HC4D-HTM-AC100V
HC4D-HTM-AC120V
HC4D-HTM-AC200V
HC4D-HTM-DC6V
HC4D-HTM-DC12V
HC4D-HTM-DC24V
HC4D-HTM-DC48V
HC4D-HTM-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
ASCTB4E 201709-T
–4–
To Be Discontinued
Last time buy: September 30, 2018
HC
2. Amber sealed type
1) Plug-in type
1 Form C
2 Form C
4 Form C
Part No.
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
6V AC
12V AC
HC1E-H-AC6V-F
HC1E-H-AC12V-F
HC1E-H-AC24V-F
HC1E-H-AC48V-F
HC1E-H-AC100V-F
HC1E-H-AC120V-F
HC1E-H-AC200V-F
HC1E-H-AC240V-F
HC1E-H-DC6V-F
HC1E-H-DC12V-F
HC1E-H-DC24V-F
HC1E-H-DC48V-F
HC1E-H-DC100V-F
HC2E-H-AC6V-F
HC2E-H-AC12V-F
HC2E-H-AC24V-F
HC2E-H-AC48V-F
HC2E-H-AC100V-F
HC2E-H-AC120V-F
HC2E-H-AC200V-F
HC2E-H-AC240V-F
HC2E-H-DC6V-F
HC2E-H-DC12V-F
HC2E-H-DC24V-F
HC2E-H-DC48V-F
HC2E-H-DC100V-F
HC4E-H-AC6V
HC4E-H-AC12V
HC4E-H-AC24V
HC4E-H-AC48V
HC4E-H-AC100V
HC4E-H-AC120V
HC4E-H-AC200V
HC4E-H-AC240V
HC4E-H-DC6V
HC4E-H-DC12V
HC4E-H-DC24V
HC4E-H-DC48V
HC4E-H-DC100V
HC4ED-H-AC6V
HC4ED-H-AC12V
HC4ED-H-AC24V
HC4ED-H-AC48V
HC4ED-H-AC100V
HC4ED-H-AC120V
HC4ED-H-AC200V
HC4ED-H-AC240V
HC4ED-H-DC6V
HC4ED-H-DC12V
HC4ED-H-DC24V
HC4ED-H-DC48V
HC4ED-H-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (With LED indication)
1 Form C
2 Form C
4 Form C
Part No.
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
6V AC
12V AC
HC1E-L-AC6V-F
HC1E-L-AC12V-F
HC1E-L-AC24V-F
HC1E-L-AC48V-F
HC1E-L-AC100V-F
HC1E-L-AC120V-F
HC1E-L-AC200V-F
HC1E-L-AC240V-F
HC1E-L-DC6V-F
HC1E-L-DC12V-F
HC1E-L-DC24V-F
HC1E-L-DC48V-F
HC1E-L-DC100V-F
HC2E-L-AC6V-F
HC2E-L-AC12V-F
HC2E-L-AC24V-F
HC2E-L-AC48V-F
HC2E-L-AC100V-F
HC2E-L-AC120V-F
HC2E-L-AC200V-F
HC2E-L-AC240V-F
HC2E-L-DC6V-F
HC2E-L-DC12V-F
HC2E-L-DC24V-F
HC2E-L-DC48V-F
HC2E-L-DC100V-F
HC4E-L-AC6V
HC4E-L-AC12V
HC4E-L-AC24V
HC4E-L-AC48V
HC4E-L-AC100V
HC4E-L-AC120V
HC4E-L-AC200V
HC4E-L-AC240V
HC4E-L-DC6V
HC4E-L-DC12V
HC4E-L-DC24V
HC4E-L-DC48V
HC4E-L-DC100V
HC4ED-L-AC6V
HC4ED-L-AC12V
HC4ED-L-AC24V
HC4ED-L-AC48V
HC4ED-L-AC100V
HC4ED-L-AC120V
HC4ED-L-AC200V
HC4ED-L-AC240V
HC4ED-L-DC6V
HC4ED-L-DC12V
HC4ED-L-DC24V
HC4ED-L-DC48V
HC4ED-L-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
3) PC board type
1 Form C
2 Form C
4 Form C
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
HC1E-HP-AC6V-F
HC1E-HP-AC12V-F
HC1E-HP-AC24V-F
HC1E-HP-AC48V-F
HC1E-HP-AC100V-F
HC1E-HP-AC120V-F
HC1E-HP-AC200V-F
HC1E-HP-AC240V-F
HC1E-HP-DC6V-F
HC1E-HP-DC12V-F
HC1E-HP-DC24V-F
HC1E-HP-DC48V-F
HC1E-HP-DC100V-F
HC2E-HP-AC6V-F
HC2E-HP-AC12V-F
HC2E-HP-AC24V-F
HC2E-HP-AC48V-F
HC2E-HP-AC100V-F
HC2E-HP-AC120V-F
HC2E-HP-AC200V-F
HC2E-HP-AC240V-F
HC2E-HP-DC6V-F
HC2E-HP-DC12V-F
HC2E-HP-DC24V-F
HC2E-HP-DC48V-F
HC2E-HP-DC100V-F
HC4E-HP-AC6V
HC4E-HP-AC12V
HC4E-HP-AC24V
HC4E-HP-AC48V
HC4E-HP-AC100V
HC4E-HP-AC120V
HC4E-HP-AC200V
HC4E-HP-AC240V
HC4E-HP-DC6V
HC4E-HP-DC12V
HC4E-HP-DC24V
HC4E-HP-DC48V
HC4E-HP-DC100V
HC4ED-HP-AC6V
HC4ED-HP-AC12V
HC4ED-HP-AC24V
HC4ED-HP-AC48V
HC4ED-HP-AC100V
HC4ED-HP-AC120V
HC4ED-HP-AC200V
HC4ED-HP-AC240V
HC4ED-HP-DC6V
HC4ED-HP-DC12V
HC4ED-HP-DC24V
HC4ED-HP-DC48V
HC4ED-HP-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only)
ASCTB4E 201709-T
–5–
To Be Discontinued
Last time buy: September 30, 2018
HC
4) PC board type (With LED indication)
1 Form C
2 Form C
4 Form C
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
HC1E-PL-AC6V-F
HC1E-PL-AC12V-F
HC1E-PL-AC24V-F
HC1E-PL-AC48V-F
HC1E-PL-AC100V-F
HC1E-PL-AC120V-F
HC1E-PL-AC200V-F
HC1E-PL-AC240V-F
HC1E-PL-DC6V-F
HC1E-PL-DC12V-F
HC1E-PL-DC24V-F
HC1E-PL-DC48V-F
HC1E-PL-DC100V-F
HC2E-PL-AC6V-F
HC2E-PL-AC12V-F
HC2E-PL-AC24V-F
HC2E-PL-AC48V-F
HC2E-PL-AC100V-F
HC2E-PL-AC120V-F
HC2E-PL-AC200V-F
HC2E-PL-AC240V-F
HC2E-PL-DC6V-F
HC2E-PL-DC12V-F
HC2E-PL-DC24V-F
HC2E-PL-DC48V-F
HC2E-PL-DC100V-F
HC4E-PL-AC6V
HC4E-PL-AC12V
HC4E-PL-AC24V
HC4E-PL-AC48V
HC4E-PL-AC100V
HC4E-PL-AC120V
HC4E-PL-AC200V
HC4E-PL-AC240V
HC4E-PL-DC6V
HC4E-PL-DC12V
HC4E-PL-DC24V
HC4E-PL-DC48V
HC4E-PL-DC100V
HC4ED-PL-AC6V
HC4ED-PL-AC12V
HC4ED-PL-AC24V
HC4ED-PL-AC48V
HC4ED-PL-AC100V
HC4ED-PL-AC120V
HC4ED-PL-AC200V
HC4ED-PL-AC240V
HC4ED-PL-DC6V
HC4ED-PL-DC12V
HC4ED-PL-DC24V
HC4ED-PL-DC48V
HC4ED-PL-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Note: Please add “-31” in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only)
5) TM type
1 Form C
2 Form C
4 Form C
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V AC
12V AC
HC1E-HTM-AC6V-F
HC1E-HTM-AC12V-F
HC1E-HTM-AC24V-F
HC1E-HTM-AC48V-F
HC1E-HTM-AC100V-F
HC1E-HTM-AC120V-F
HC1E-HTM-AC200V-F
HC1E-HTM-AC240V-F
HC1E-HTM-DC6V-F
HC1E-HTM-DC12V-F
HC1E-HTM-DC24V-F
HC1E-HTM-DC48V-F
HC1E-HTM-DC100V-F
HC2E-HTM-AC6V-F
HC2E-HTM-AC12V-F
HC2E-HTM-AC24V-F
HC2E-HTM-AC48V-F
HC2E-HTM-AC100V-F
HC2E-HTM-AC120V-F
HC2E-HTM-AC200V-F
HC2E-HTM-AC240V-F
HC2E-HTM-DC6V-F
HC2E-HTM-DC12V-F
HC2E-HTM-DC24V-F
HC2E-HTM-DC48V-F
HC2E-HTM-DC100V-F
HC4E-HTM-AC6V
HC4E-HTM-AC12V
HC4E-HTM-AC24V
HC4E-HTM-AC48V
HC4E-HTM-AC100V
HC4E-HTM-AC120V
HC4E-HTM-AC200V
HC4E-HTM-AC240V
HC4E-HTM-DC6V
HC4E-HTM-DC12V
HC4E-HTM-DC24V
HC4E-HTM-DC48V
HC4E-HTM-DC100V
HC4ED-HTM-AC6V
HC4ED-HTM-AC12V
HC4ED-HTM-AC24V
HC4ED-HTM-AC48V
HC4ED-HTM-AC100V
HC4ED-HTM-AC120V
HC4ED-HTM-AC200V
HC4ED-HTM-AC240V
HC4ED-HTM-DC6V
HC4ED-HTM-DC12V
HC4ED-HTM-DC24V
HC4ED-HTM-DC48V
HC4ED-HTM-DC100V
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
4. With diode type (For DC)
1) Plug-in type
1 Form C
2 Form C
3 Form C
Part No.
4 Form C
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
HC4-DC6V-D
HC4-DC12V-D
HC4-DC24V-D
HC4-DC48V-D
HC4-DC100V-D
6V DC
12V DC
HC1-DC6V-D-F
HC1-DC12V-D-F
HC1-DC24V-D-F
HC1-DC48V-D-F
HC1-DC100V-D-F
HC2-DC6V-D-F
HC2-DC12V-D-F
HC2-DC24V-D-F
HC2-DC48V-D-F
HC2-DC100V-D-F
HC3-DC6V-D-F
HC3-DC12V-D-F
HC3-DC24V-D-F
HC3-DC48V-D-F
HC3-DC100V-D-F
HC4D-DC6V-D
HC4D-DC12V-D
HC4D-DC24V-D
HC4D-DC48V-D
HC4D-DC100V-D
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2) Plug-in type (with LED indication)
1 Form C
2 Form C
3 Form C
4 Form C
Part No.
4 Form C (twin)
Part No.
Nominal coil voltage
Part No.
Part No.
Part No.
6V DC
12V DC
HC1-L-DC6V-D-F
HC1-L-DC12V-D-F
HC1-L-DC24V-D-F
HC1-L-DC48V-D-F
HC1-L-DC100V-D-F
HC2-L-DC6V-D-F
HC2-L-DC12V-D-F
HC2-L-DC24V-D-F
HC2-L-DC48V-D-F
HC2-L-DC100V-D-F
HC3-L-DC6V-D-F
HC3-L-DC12V-D-F
HC3-L-DC24V-D-F
HC3-L-DC48V-D-F
HC3-L-DC100V-D-F
HC4-L-DC6V-D
HC4-L-DC12V-D
HC4-L-DC24V-D
HC4-L-DC48V-D
HC4-L-DC100V-D
HC4D-L-DC6V-D
HC4D-L-DC12V-D
HC4D-L-DC24V-D
HC4D-L-DC48V-D
HC4D-L-DC100V-D
24V DC
48V DC
100/110V DC
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
* Sockets and mounting boards available
ASCTB4E 201709-T
–6–
To Be Discontinued
Last time buy: September 30, 2018
HC
RATING
1. Standard type
1) Coil data
(1) AC coils (50/60Hz)
Nominal coil current
[ 20%] (at 20°C 68°F)
Nominal operating
power
Coil inductance
Drop-out
voltage*
(at 20°C 68°F)
Max. applied
voltage
(at 70°C 158°F)
Nominal coil Pick-up voltage*
Type
voltage
(at 20°C 68°F)
N.C.
N.O.
condition
50Hz
60Hz
50Hz
60Hz
condition
6V AC
12V AC
224mA
111mA
200mA
100mA
0.078H
0.312H
1.243H
4.974H
23.75H
27.19H
85.98H
0.074H
0.295H
1.181H
4.145H
20.63H
25.57H
81.76H
30%V or more
of nominal
voltage
24V AC
56mA
50mA
80%V or less of
nominal voltage
(Initial)
110%V of
nominal voltage
Standard
48V AC
28mA
25mA
1.3VA
1.2VA
100/110V AC
110/120V AC
200/220V AC
13.4/14.7mA
12.2/13.5mA
6.7/7.4mA
12/13.2mA
10.9/11.9mA
6/6.6mA
(Initial)
* Square, pulse drive
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow
leading possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
(2) DC coils
Nominal coil current
[ 10%]
(at 20°C 68°F)
Coil resistance
[ 10%]
(at 20°C 68°F)
Nominal coil
voltage
Pick-up voltage*
(at 20°C 68°F)
Drop-out voltage*
(at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 70°C 158°F)
Type
6V DC
12V DC
150mA
75mA
40Ω
160Ω
650Ω
2,600Ω
10,000Ω
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
0.9W
1.0W
110%V of
nominal voltage
Standard
24V DC
37mA
48V DC
18.5mA
10/11mA
100/110V DC
* Square, pulse drive
Notes: 1. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate 0.4% for every 1°C change in temperature.
2. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
3. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
4. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
ASCTB4E 201709-T
–7–
To Be Discontinued
Last time buy: September 30, 2018
HC
2) Specifications
Characteristics
Item
Specifications
3 Form C
Arrangement
1 Form C
2 Form C
4 Form C
4 Form C (twin)
Contact
Contact resistance (Initial)
Contact material
Max. 30 mΩ (By voltage drop 6 V DC 1A)
Ag alloy (cd free) + Au flash
AgNi type + Au clad
Nominal switching capacity
(resistive load)
10A 250V AC
2,500VA
7A 250V AC
1,750VA
7A 250V AC
1,750VA
5A 250V AC
1,250VA
3A 250V AC
750VA
Max. switching power
(resistive load)
Rating
Max. switching voltage
Max. switching current*4
250VAC
7A
10A
7A
5A
3A
Min. switching capacity
(Reference value)*1
1mA 1V DC
100μA 1V DC
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open
contacts
700 Vrms for 1min. (Detection current: 10mA.)
Breakdown
Between contact
voltage
700 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
sets
(Initial)
Electrical
characteristics
Between contact
and coil
Operate time
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(initial, at 20°C 68°F)*2
Release time
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
(initial, at 20°C 68°F)*2
Functional
Shock
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
resistance
Destructive
Functional
Destructive
Mechanical
characteristics
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 2 mm
Vibration
resistance
Mechanical
Min. 5×107: AC coil type (at 180 times/min.); Min. 108: DC coil type (at 180 times/min.)
Min. 2×105
Min. 2×105
Min. 105
resistive load
(at 20 times/min.)
Min. 2×105
Min. 2×105
Expected life
Electrical
resistive load
resistive load
resistive load
resistive load
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
(at 20 times/min.)
Conditions for operation,
transport and storage*3
Ambient temperature: –50 to +70°C –58 to +158°F (without LED); –50 to +60°C –58 to +140°F (with LED)
Conditions
Unit weight
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Approx. 30g 1.06 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. For the ambient temperature, refer to “NOTES”.
*4. When using the socket and terminal socket, be sure to verify the max. continuous current.
3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
AC
DC
Load
Resistive (cos ϕ = 1)
Inductive (cos ϕ 0.4)
125V AC 250V AC
5A 3A
Resistive
30V DC
—
Inductive
30V DC
—
Expected life
Voltage
125V AC
250V AC
10A
7A
10A
7A
5A
7A
5A
3A
7A
—
Min. 2×105
Min. 5×105
Min. 106
1 Form C
2 Form C
3 Form C
3A
2A
2.5A
1.5A
2A
3A
1A
5A
—
—
7A
3.5A
2.5A
1.5A
—
—
—
Min. 2×105
Min. 5×105
Min. 106
5A
1.5A
1A
3A
0.6A
—
3A
—
7A
—
—
—
Min. 105
—
3.5A
—
2A
—
—
Min. 2×105
Min. 5×105
Min. 2×105
Min. 5×105
Min. 106
5A
5A
3A
2A
3A
5A
—
3A
0.4A
—
5A
2A
1A
—
4 Form C
3A
1A
0.8A
0.4A
0.8A
3A
0.4A
—
2A
0.5A
1A
—
4 Form C (twin)
3A
3A
—
Min. 2×105
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108
ASCTB4E 201709-T
–8–
To Be Discontinued
Last time buy: September 30, 2018
HC
2. Amber sealed type
1) Coil data
Same coil data as HC relay standard type. Please refer to standard type information.
2) Specifications
Specifications
Characteristics
Contact
Item
1 Form C
1 Form C
5A 250V AC
1,250VA
250VAC
5A
2 Form C
2 Form C
4 Form C
4 Form C
2A 250V AC
500VA
4 Form C (twin)
Arrangement
4 Form C
1A 250V AC
250VA
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
3A 250V AC
700VA
Rating
250VAC
250VAC
2A
250VAC
Max. switching current
3A
1A
Min. switching capacity (Reference value)*1
1mA 100mV DC
100μA 100mV DC
Expected life
Conditions
Electrical
Min. 2×105 resistive load (at 20 times/min.)
Ambient temperature: –40°C to +60°C –40°F to +140°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions for operation, transport and
storage*2
Notes: Other specifications are same as standard types.
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the ambient temperature, refer to “NOTES”.
3) Switching capacity and expected life
(1) Electrical (at 20 times/min.)
AC
DC
Load
Resistive (cos ϕ = 1)
Inductive (cos ϕ 0.4)
125V AC 250V AC
Resistive
30V DC
3A
Inductive
30V DC
1A
Expected life
Voltage
HC1E
125V AC
250V AC
5A
5A
3A
2A
1A
—
—
Min. 2×105
Min. 2×105
Min. 2×105
Min. 2×105
HC2E
3A
—
—
—
—
—
—
2A
0.7A
HC4E
2A
2A
0.6A
HC4ED (4 Form C twin)
1A
—
—
(2) Mechanical (at 180 times/min.)
AC coil type: Min. 5×107; DC coil type: Min. 108
3. With diode type (For DC)
1) Coil data
Same coil data as HC relay standard type for DC. Please refer to standard type information.
Please connect DC coil type built-in diode correctly by verifying the coil polarity.
2) Specifications
Characteristics
Item
Specifications
Ambient temperature: –50°C to +60°C –58°F to +140°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Conditions for operation, transport and storage*
Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay.
* For the ambient temperature, refer to “NOTES”.
ASCTB4E 201709-T
–9–
To Be Discontinued
Last time buy: September 30, 2018
HC
REFERENCE DATA
Standard type
1. Life curve
2.-(1) Max. switching capacity
2.-(2) Max. switching capacity
Load: 250 V AC resistive load
(single contact type)
[4-pole bifurcated (twin) contact type]
10
1c
2c, 3c
4c
7
5
10,000
Mechanical life (DC type)
5,000
1c, 2c, 3c, 4c
Mechanical life (AC type)
3
3
DC
AC
resistive
load
DC
resistive
load
AC
resistive
load
resistive
load
500
400
1c
(250 V AC cosϕ = 1)
0.4
0.1
0.4
0.1
300
2c
200
3c
100
4c
2
4
6
8
10
10
30
125 250
Contact voltage, V
10
30
125 250
Contact voltage, V
Load current, A
3.-(1) Coil temperature rise
(1 Form C, AC type)
3.-(2) Coil temperature rise
(2 Form C, AC type)
3.-(3) Coil temperature rise
(3 Form C, AC type)
Measured portion: Inside the coil
Ambient temperature: 25°C 77°F
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
100
Measured portion: Inside the coil
Ambient temperature: 18°C 64°F
(See note.)
(See note.)
(See note.)
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
7A
90
80
70
60
50
40
30
20
10
0
10A
10A
5A
0A
5A
0A
7A
5A
2A
0A
80
90
100
110
120
80
90
100
110
120
80
90
100
110
120
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
3.-(4) Coil temperature rise
(4 Form C, AC type)
3.-(5) Coil temperature rise
(1 Form C, DC type)
3.-(6) Coil temperature rise
(2 Form C, DC type)
Measured portion: Inside the coil
Ambient temperature: 15 to 21°C 59 to 70°F
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
(See note.)
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
180
160
140
120
100
80
7A
10A
5A
3A
5A
0A
5A
0A
1A
60
40
20
0
80
90
100
110
120
80
90
100
110
120
80
90
100
110
120
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
3.-(7) Coil temperature rise
(3 Form C, DC type)
Measured portion: Inside the coil
Ambient temperature: 29°C 84°F
100
3.-(8) Coil temperature rise
(4 Form C, DC type)
Measured portion: Inside the coil
Note: Coil temperature rise
When the nominal voltage is applied to 120 or 240 V
AC coil types respectively, the figures of coil
temperature rise increase by approx. 10 degrees to
the ones shown on each graph.
Ambient temperature: 17 to 18°C 62 to 64°F
100
90
80
70
60
50
40
30
20
10
0
90
80
5A
7A
5A
0A
70
60
50
40
30
20
10
0
3A
1A
80
90
100
110
120
80
90
100
110
120
Coil applied voltage, %V
Coil applied voltage, %V
ASCTB4E 201709-T
–10–
To Be Discontinued
Last time buy: September 30, 2018
HC
Amber sealed type
1.-(1) Max. switching capacity
1.-(2) Max. switching capacity
2.-(1) Coil temperature rise (1 Form C AC type)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
(single contact type)
[4-pole bifurcated (twin) contact type]
100
90
5
80
1c
1c, 2c, 3c, 4c
3
2
AC
resistive
load
70
2c
4c
5A
60
1c
50
40
30
20
10
0
1
AC
2c, 4c
resistive
load
0.4
0.1
0.4
DC resistive load
30
DC resistive load
30
0.1
10
80
90
100
110
120
10
125 250
Contact voltage, V
125 250
Contact voltage, V
Voltage applied to coil, %V
2.-(2) Coil temperature rise (2 Form C AC type)
Measured portion: Inside the coil
2.-(3) Coil temperature rise (4 Form C AC type)
Measured portion: Inside the coil
2.-(4) Coil temperature rise (1 Form C DC type)
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
Ambient temperature: 30°C 86°F
(See note.)
Ambient temperature: 30°C 86°F
(See note.)
100
100
100
90
80
70
60
90
80
70
60
50
40
30
20
10
0
90
80
70
60
50
40
30
20
10
0
2A
3A
50
40
30
20
10
0
5A
0A
80
90
100
110
120
80
90
100
110
120
80
90
100
110
120
Voltage applied to coil, %V
Voltage applied to coil, %V
Voltage applied to coil, %V
2.-(5) Coil temperature rise (2 Form C DC type)
Note: Coil temperature rise
Measured portion: Inside the coil
Ambient temperature: 30°C 86°F
When the nominal voltage is applied to 120 or 240 V
AC coil types respectively, the figures of coil
temperature rise increase by approx. 10 degrees to
the ones shown on each graph.
100
90
80
70
60
5A
50
40
30
20
10
0
80
90
100
110
120
Voltage applied to coil, %V
With diode type (For DC)
1.-(1) DC coil surge voltage waveform
(without diode)
1.-(2) DC coil surge voltage waveform
(with diode)
Diode characteristics;
Reverse breakdown voltage: 1,000V,
Forward current: 1A
ON
OFF
ON
OFF
260V
+
To digital
memory
12V DC
+
–
To digital
memory
12V DC
–
Reverse breakdown voltage: 1,000 V
Forward current: 1 A
(
(
ASCTB4E 201709-T
–11–
To Be Discontinued
Last time buy: September 30, 2018
HC
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
Standard type
1) Plug-in type
1 Form C
External dimensions
Schematic (Bottom view)
Without LED indication type
(AC/DC)
CAD Data
20.8
.819
27.2
1.7
1.7
0.6
1.071
.067
.067
.024
2
7
12
35.2
13
1.386
14
1
.039
LED AC type
LED DC type
6.4
.252
2
2
7
7
2.54
.100
0.5
12
14
∼
12
.020
13.35
13
13
.526
14
(+)
(−)
( )
∼
4.45
4.41
.174
(
)
.175
2
4.06
7
.160
6.35
.250
6.35
.250
12
14
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
13
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch:
0.3 .012
2 Form C
External dimensions
Schematic (Bottom view)
Without LED indication type
(AC/DC)
CAD Data
20.8
.819
27.2
1.7
1.7
0.6
1.071
.067
.067
.024
1
5
4
8
9
12
35.2
14
13
1.386
1
.039
LED AC type
LED DC type
6.4
.252
1
5
4
8
1
5
4
8
2.54
.100
13.35
.526
0.5
.020
9
12
9
12
4.41
.174
13
13
14
14
(+)
(
)
∼
(−)
(
∼
)
1
5
4
8
4.06
.160
6.35
.250
6.35
.250
9
12
14
13
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch:
0.3 .012
3 Form C
External dimensions
Schematic (Bottom view)
Without LED indication type
(AC/DC)
CAD Data
20.8
.819
27.2
1.7
1.7
0.6
1.071
.067
.067
.024
1
4
7
2
5
8
3
6
9
35.2
1.386
14
13
1
.039
6.4
LED AC type
LED DC type
.252
1
4
7
1
4
7
2
5
8
2
5
8
3
3
6
9
0.5
2.54
.100
13.35
.020
6
9
4.41
.174
.526
1
4
2
3
6
13
13
4.06
14
∼
14
(+)
5
( )
∼
(−)
.160
6.35
.250
6.35
.250
(
)
7
8
9
13
14
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
ASCTB4E 201709-T
–12–
To Be Discontinued
Last time buy: September 30, 2018
HC
4 Form C and 4-pole bifurcated (twin)
External dimensions
Schematic (Bottom view)
Without LED indication type
(AC/DC)
CAD Data
20.8
.819
1.7
1.7
27.2
0.6
.067
.067
1.071
.024
1
5
2
6
3
7
4
8
35.2
9
10
11
12
14
1.386
13
1
.039
LED AC type
LED DC type
6.4
.252
1
5
2
6
3
7
4
8
1
2
6
3
7
4
0.5
2.54
.100
5
8
.020
4.41
.174
13.35
4.45
.175
.526
11
12
14
∼
9
10
11
12
9
10
1
5
2
6
3
7
4
8
13
13
4.06
14
(+)
( )
∼
(−)
.160
6.35
.250
6.35
.250
(
)
9
10 11 12
14
13
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
2) PC board type
4 Form C
External dimensions
CAD Data
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
20.8
.819
27.2
1.7
1.7
0.6
1.071
.067
.067
.024
35.2
Types with 0.9 mm .035 inch terminal width are
also available.
1.386
1
.039
1.5
.059
3.5
.138
0.5
1.5
.059
.020
13.35
.526
4.45
.175
4.41
.174
1
5
2
6
3
7
4
8
4.06
.160
6.35
.250
9
10 11 12
14
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Tolerance
6.35
13
.250
0.1 .004
Min. 3mm .118 inch:
0.3 .012
PC board pattern
Schematic
Same schematic as plug-in type HC relay
1 Form C
2 Form C
3 Form C
4 Form C
4.1
4.1
4.1
4.1
.161
.161
.161
.161
10.4
.409
10.4
.409
16.8
.661
10.4
.409
10.4
.409
16.8
.661
16.8
16.8
.661
.661
11-2 dia. hole
11-.079 dia.
4.45
.175
4.45
.175
8-2 dia. hole
8-.079 dia.
13.35
.526
5-2 dia. hole
5-.079 dia.
14-2 dia. hole
8.9
13.35
.526
8.9
14-.079 dia.
.350
13.35
.526
.350
13.35
.526
Tolerance: 0.1 .004
ASCTB4E 201709-T
–13–
To Be Discontinued
Last time buy: September 30, 2018
HC
3) TM type
4 Form C
External dimensions
CAD Data
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
20.6
43
.811
1.693
2
.079
34.2
1.346
1
.039
6.4
.252
2.54
.100
0.5
Schematic
.020
13.35
.526
Same schematic as plug-in type HC relay
Be aware that there is no LED indicator with
built-in diode types.
4.45
.175
4.31
.170
3.6
.142
1
5
2
6
3
7
4
8
4.06
.160
37.6
1.480
10
11 12
6.35
9
27
1.063
.250
6.35
.250
13
14
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
Tolerance
0.1 .004
Chassis (Panel) cutout
Chassis (Panel) cutout in tandem mounting
23
2-3.6 dia.
.906
2-.142 dia.
37.6
1.480
37.6
1.480
21
21
Tolerance: 0.1 .004
.827
.827
2
.079
Notes: 1. In mounting, use M3 screws and M3 washers.
2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover.
3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).
Moreover, use washers to prevent loosening.
ASCTB4E 201709-T
–14–
To Be Discontinued
Last time buy: September 30, 2018
HC
Amber sealed type
1) Plug-in type
1 Form C
External dimensions
Schematic (Bottom view)
Without LED indication type
(AC/DC)
CAD Data
27.4
1.079
2
7
21.0
.827
12
Indication of DC coil
indicates only with
LED indication type
13
14
35.2
LED AC type
LED DC type
1.386
2
7
2
7
14
13
12
(~)
14
12
6.4
2.54
.100
0.5
.020
(~)
13
(−)
(+)
.252
13
14
4.06 .160
4.51 .178
6.35 .250
6.35 .250
(12) (14)
(7)
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Tolerance
0.1 .004
13.35
.526
(2)
(13)
4.45
.175
Min. 3mm .118 inch:
0.3 .012
2 Form C
External dimensions
Schematic (Bottom view)
Without LED indication type
(AC/DC)
CAD Data
27.4
1.079
1
5
4
8
21.0
.827
9
12
14
Indication of DC coil
indicates only with
LED indication type
13
35.2
LED AC type
LED DC type
1.386
1
5
4
8
1
5
4
8
14
13
9
12
9
12
6.4
2.54
.100
0.5
.020
(~)
13
(~)
14
(−)
(+)
14
.252
13
4.06 .160
4.51 .178
6.35 .250
6.35 .250
(4) (8) (12) (14)
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
13.35
.526
(1) (5)
(9) (13)
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch:
0.3 .012
4 Form C and 4-pole bifurcated (twin)
External dimensions
Schematic (Bottom view)
Without LED indication type
(AC/DC)
CAD Data
27.4
1.079
1
5
2
6
3
7
4
8
21.0
.827
9
10 11 12
14
Indication of DC coil
indicates only with
LED indication type
13
35.2
LED AC type
LED DC type
1.386
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
14
13
9
10 11 12
9
10 11 12
6.4
2.54
.100
0.5
.020
(~)
13
(−)
13
(~)
14
(+)
.252
14
4.06 .160
4.51 .178
6.35 .250
6.35 .250
(4) (8) (12) (14)
(3) (7) (11)
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Tolerance
0.1 .004
13.35
.526
(2) (6) (10)
(1) (5) (9) (13)
4.45
.175
Min. 3mm .118 inch:
0.3 .012
ASCTB4E 201709-T
–15–
To Be Discontinued
Last time buy: September 30, 2018
HC
2) PC board type
4 Form C and 4-pole bifurcated (twin)
External dimensions
CAD Data
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
27.4
1.079
21.0
.827
Types with 0.9 mm .035 inch terminal width are
also available.
Indication of DC coil
indicates only with
LED indication type
35.2
1.386
Schematic
Same schematic as plug-in type HC relay
14
13
5
.197
0.5
.020
3.5
1.5
.059
.138
4.06 .160
4.51 .178
6.35 .250
6.35 .250
(4) (8) (12) (14)
(3) (7) (11)
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Tolerance
0.1 .004
13.35
.526
(2) (6) (10)
(1) (5) (9) (13)
4.45
.175
Min. 3mm .118 inch:
0.3 .012
PC board pattern
6.35 .250
6.35 .250
4.06
.160
4.45
.175
13.35
.526
14-2 dia. hole
14-.079 dia. hole
Tolerance: 0.1 .004
3) TM type
4 Form C and 4-pole bifurcated (twin)
External dimensions
CAD Data
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).
2
.079
34.5
1.358
Schematic
6.4
0.5
.020
2.54
.100
.252
Same schematic as plug-in type HC relay
Be aware that there is no LED indicator with
built-in diode types.
43.0
1.693
37.6
1.480
27.6
1.087
4.06 .160
4.61 .181
6.35 .250
6.35 .250
Chassis (Panel) cutout in tandem mounting
4
3
2
1
8
7
6
5
12 14
11
13.35 21.0
.526 .827
23
10
.906
9
13
3.6 4.45
37.6
.142 .175
1.480
21
21
.827
.827
Chassis (Panel) cutout
2
.079
2-3.6 dia.
2-.142 dia.
37.6
1.480
Dimension:
Less than 1mm .039inch:
Tolerance
0.1 .004
Min. 1mm .039inch less than 3mm .118 inch: 0.2 .008
Min. 3mm .118 inch: 0.3 .012
Tolerance: 0.1 .004
Notes: 1. In mounting, use M3 screws and M3 washers.
2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover.
3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).
Moreover, use washers to prevent loosening.
ASCTB4E 201709-T
–16–
To Be Discontinued
Last time buy: September 30, 2018
HC
With diode type (For DC)
Same dimensions as HC relay standard/plug-in type
CAD Data
Schematic
Without LED indicator
With LED indicator
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
9
10 11 12
9
10 11 12
13−
+14
13−
+14
LED
Protection (surge-absorbing) diode
Protection (surge-absorbing) diode
SAFETY STANDARDS
UL/C-UL (Recognized)
Item
CSA (Certified)
VDE (Certified)
Contact rating
TV rating (UL/CSA)
Remarks
File No.
Contact rating
File No.
LR26550
Contact rating
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
File No.
File No.
Rating
E43028
10A 250V AC
1/3HP 125, 250V AC etc.
3A 30V DC
40017406 10A 250V AC (cosφ=1.0) UL
TV-3
TV-3
3A 250V AC (cosφ=0.4)
3A 30V DC (0ms)
E43149
CSA
LR26550
1 Form C
E43028
7A 250V AC
1/6HP 125, 250V AC etc.
3A 30V DC
LR26550
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
40017406 7A 250V AC (cosφ=1.0)
2A 250V AC (cosφ=0.4)
3A 30V DC (0ms)
UL
E43149
CSA
LR26550
2 Form C
3 Form C
HC
Standard
E43028
E43028
7A 250V AC
1/6HP 125, 250V AC etc.
3A 30V DC
LR26550
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
—
—
—
—
5A 250V AC
LR26550
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
40017406 5A 65V AC (cosφ=1.0)
3A 65V AC (cosφ=0.4)
3A 30V DC (0ms)
4 Form C
1/10HP 125, 250V AC etc.
3A 30V DC
—
—
—
—
—
—
E43149
E43028
3A 250V AC
3A 30V DC
LR26550
etc.
3A 250V AC
3A 30V DC
4 Form C twin
1 Form C
—
—
—
—
6A 250V AC
1/6HP 125, 250V AC etc.
3A 30V DC
LR26550
6A 250V AC
1/6HP 125, 250V AC
3A 30V DC
E43028
E43028
4A 250V AC
1/10HP 125, 250V AC etc.
3A 30V DC
LR26550
4A 250V AC
1/10HP 125, 250V AC
3A 30V DC
2 Form C
—
—
—
—
HC Amber
2A 250V AC
1/20HP 125, 250V AC etc.
2A 30V DC
LR26550
2A 250V AC
1/20HP 125, 250V AC
2A 30V DC
4 Form C
—
—
—
—
—
—
—
—
—
—
—
—
E43149
E43028
1A 250V AC
1A 30V DC
LR26550
etc.
1A 250V AC
1A 30V DC
4 Form C twin
1 Form C
10A 250V AC
1/3HP 125, 250V AC etc.
3A 30V DC
LR26550
10A 250V AC
1/3HP 125, 250V AC
3A 30V DC
E43028
E43028
E43028
E43149
7A 250V AC
1/6HP 125, 250V AC etc.
3A 30V DC
LR26550
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
2 Form C
3 Form C
—
—
—
—
—
—
—
—
HC with
diode type
(For DC)
7A 250V AC
1/6HP 125, 250V AC etc.
3A 30V DC
LR26550
7A 250V AC
1/6HP 125, 250V AC
3A 30V DC
5A 250V AC
1/10HP 125, 250V AC etc.
3A 30V DC
LR26550
5A 250V AC
1/10HP 125, 250V AC
3A 30V DC
4 Form C
—
—
—
—
—
—
—
—
3A 250V AC
3A 30V DC
LR26550
etc.
3A 250V AC
3A 30V DC
4 Form C twin
NOTES
1. For cautions for use, please read
“General Application Guidelines”.
2. Diode characteristics
3. Diode type
4. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
Since the diode inside the relay coils are
designed to absorb the counter emf, the
element may be damaged if a large
surge, etc., is applied to the diode. If
there is the possibility of a large surge
voltage from the outside, please
1) Reverse breakdown voltage: 1,000 V
2) Forward current: 1 A
implement measures to absorb it.
ASCTB4E 201709-T
–17–
相关型号:
HC1-HPL-AC120V-31-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-AC120V-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-AC12V-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-AC200V-31-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-AC200V-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-AC24V-31-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-AC6V-F
Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-DC100V-F
Power/Signal Relay, SPDT, Momentary, 0.011A (Coil), 110VDC (Coil), 1000mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-DC12V-31-F
Power/Signal Relay, SPDT, Momentary, 0.075A (Coil), 12VDC (Coil), 900mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-DC12V-F
Power/Signal Relay, SPDT, Momentary, 0.075A (Coil), 12VDC (Coil), 900mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-DC24V-31-F
Power/Signal Relay, SPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
HC1-HPL-DC24V-F
Power/Signal Relay, SPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), DC Input, AC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明